high resolution melts · melting curves-normalized by selecting linear regions before and after the...

17
1 High Resolution Melts HRM www.corbettresearch.com Prepared by Andrea Tesoriero Presented by Jennifer McMahon corbett LIFE SCIENCE 2 High Resolution Melts Analysis of change in fluorescence as a PCR product is melted PCR amplify an amplicon with two primers and an intercalation dye and then melt the product – double stranded to single stranded Detect difference between a single base pair change.

Upload: others

Post on 14-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

1

1

High Resolution Melts HRM

www.corbettresearch.com

Prepared by Andrea Tesoriero

Presented by Jennifer McMahon

corbettLIFE SCIENCE

2

High Resolution Melts

Analysis of change in fluorescence as a PCR product is melted

PCR amplify an amplicon with two primers and an intercalation dye and then melt the product – double stranded to single stranded

Detect difference between a single base pair change.

Page 2: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

2

3

High Resolution Melt Specifications

Instrument requires:high-intensity + high sensitivity optics

high-speed data capture

very precise temperature control and resolution

saturating intercalation dye

4

the world’s only real-time rotary thermo-optical analyser with HRM capabilities

Page 3: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

3

5

Cross-section of rotary optics

Reaction Chamber

PMT DetectorAssembly

LED Light Source

AssemblyTubes Spin inRotor (Red)

Lens

Detection Filters

Spindle/Motor Assembly

6

THERMAL UNIFORMITY--/+0.01C

Page 4: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

4

7

Centrifugal fan drives air around chamber

Chamber vent seals to contain air

Heating mechanism

Note: holes in the rotor allow

free airflow

Heater elements switch on

8

Cool air in

Centrifugal fan Drives air into chamber

Centrifugal fan drives air around chamber

Chamber vent opens expelling hot air

Cooling mechanism

Heater elements switch off

Note: holes in the rotor allow

free airflow

Page 5: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

5

9

Saturating dye technology for HRM -LCGreen™ I, EVA Green, Syto 9

LC Green™ I

Saturation dyes are less toxic,so concentration usedcan be high enough to allow all sites to be saturated

Saturation eliminates potential for dye relocation-ideal for HRM

SYBR™ Green I is toxic to PCR,so concentration used is very low

Intercalation Chemistries

SYBR® Green I

Unsaturated binding allows dye to relocate as melting begins

10

Setting up a Reaction

Use standard PCR conditions as a starting point, typically 250nM primer, 1.5mM Magnesium chloride, 0.2mM dNTPs, 1.25 U Platinum Taq, 1.5µM SYTO 9, 50ng DNADon’t generally usually use real-time mix – decreases cost per assaySet up cycling and add HRM step at the endHRM step typically 0.1°C steps over 10 °C, HRM step takes around 20 minutes

Page 6: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

6

11

HRM Profile

0.02deg

12

Data Acquisition

Melting curves-normalized by selecting linear regions before and after the melting transitionTwo regions defined-upper 100% double stranded and lower single stranded baseline

Page 7: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

7

13

Homoduplexes C or T

Homozygotes represented by a single base changeare differentiated by a difference in Tm melt.

T

A

C

G

14

Heteroduplex C>T

Heterozygotes form heteroduplexes, the heterozygote (blue) trace is a mix of 4 duplexes

C

G

T

A

T

G

C

A

+C

G

T

A

++

Page 8: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

8

15

Mutants(T a lle le)

Wild types(C a lle le)

Heterozygotes

Mutants(T a lle le)

Wild types(C a lle le)

Heterozygotes

•ACTN3 (R577X) (C—T).•10 replicates.•40 cycle fast(~34 min).

SOFTWARE: Normalised HRM data

16

Difference Graphs

Difference graph displays the difference between each sample and a given genotype controlAllows a calculated percentage confidence relative to a known genotype

Page 9: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

9

17

Confidence in HRM Results

Wildtype (72 Replicates)

Mean Tm 78.78 +0.04% Mean Tm 77.90 +0.04%

Mutant (72 Replicates)

18

Applications

SNP genotyping/ Allelic discriminationIdentify Candidate Predisposition Genes

Association Studies-eg.comparing cases and controls, genotype to phenotype

Prevalence -within population or different sub groups

Loss of Heterozygosity

DNA fingerprinting

Mutation Discovery/Screening/Scanning

Predictive TestingPenetrance/Linkage studies-variant track with disease within a family

Species Identification

Page 10: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

10

19

GenotypingClass 4 SNP

7%A/T4

9%C/G3

20%C/A and G/T264%Large>0.5oC

Very Small >0.2oC

C/T and G/A1

Rarity (in humans)

Typical TmShift

Base Change

SNP Class

Example of a class 4 SNP on the Rotor Gene (MCT A1470T)The rarest and most difficult SNP to discriminate.

SNP classes as described by Venter et al 2002

20

“Spiking” Experiments

Royal Melbourne Hospital

Homozygous A(dark blue)

Homozygous B(Green)

Page 11: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

11

21

Tm Comparisons-Factor V G1691A

63bp tctgaaaggttacttcaaggacaaaatacctgtattccTtgcctgtccagggatctgctctta89bp ggttacttcaaggacaaaatacctgtattccTtgcctgtccagggatctgctcttacagattagaagtagtcctattagcccagaggcg169bp ttgaaggaaatgccccattatttagccaggagacctaacatgttctagccagaagaaattctcagaatttctgaaaggttacttcaaggac

aaaatacctgattccTtgcctgtccagggatctgctcttacagattagaagtagtcctattagcccagaggcgatgt

0.72 ± 0.0482.21 ± 0.0281.49 ± 0.02169bp

0.57 ± 0.0480.03 ± 0.0279.46 ± 0.0289bp

0.68 ± 0.0578.18 ± 0.0177.50 ± 0.0463bp

Tm Homozygote's

WildtypeMutationAmplicon size

22

Sensitivity-Somatic Mutation Discovery 189 bp product 37% GC content

wt

?

Detect small quantities of mutant DNA in a background of wildtype DNA species-sensitivity 5%No homozygous spiking necessary

PMCI-Melbourne

Page 12: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

12

23

Sequencing –Somatic variants

wt

Patient 1838 G>A

Patient 13 35 G>T

Patient 6 34 G>T

Patient 22 35 G>T

Forward 3’ Reverse 5’

Sequence directly of the product-product column purified and not consumed

24

Difference Graph

wt

38 G>A

35 G>T

34 G>T

35 G>T

38 G>A

35 G>C

Page 13: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

13

25

White et al. 2006 report

http://www.ngrl.org.uk/Wessex/downloads.htm

26

White et al. 2006 report

Page 14: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

14

27

White et al. 2006 report

28

White et al. 2006 report

Page 15: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

15

29

White et al. 2006 report

30

DNA Quality

DNA quality-Multiplex 100, 200, 300, 400 and 600pb product

Amplification of 193bp product

Page 16: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

16

31

Poor Quality DNA in = poor results out!Important to view your data Real Time to check DNA quality

Guidleines:

Assess the CT values - integrity of your DNAAssess the amplification efficiencyAssess the derivative plot melt curves-is there one product? Is the PCR optimized? Primer-dimer issues?

Using the Real Time data allows you to make OBJECTIVE decisions about the changes observed

32

Applications

Detect small quantities of mutant DNA in background of wildtype DNA speciesImportant in somatically acquired mutationsPooling samples-up to 10 samplesSimple for diseases that cause no heterogeneity-like Factor V Leiden, haemochromotosis, sickle cell anemiaNewly identified genes-little information

Page 17: High Resolution Melts · Melting curves-normalized by selecting linear regions before and after the melting transition Two regions defined-upper 100% double stranded and lower single

17

33

Summary

Simple, fast, cost effective method for gene scanning and detecting a single-base change in your sample Rapid cycle PCR with HRM analysis set up at one timeNO labeled probes, cheap intercalation dyeNO Post-PCR processing with additional reagents such as sequencing, DHPLC, RFLPExcellent sensitivity and specificity - capable of detecting BOTH heterozygous and homozygous changesCosts less than competing technologiesSequence directly off the product- sample not consumedDetect from a pool of 10 samples -1/20 alleles, 5% sensitivityAuto call softwareScanning and genotyping can be performed simultaneously in the same reaction

34

Sydney AustraliaCorbett Research Pty Ltd14 Hilly StreetMortlake, NSW 2137T +61 2 9736 1320F +61 2 9736 1364

United KingdomCorbett Research UK LimitedUnit 296 Cambridge Science ParkMilton, Cambridge CB4 0WDT +44 (0)1223 424 288F +44 (0)1223 424 144

All slides 2006 Corbett Life Science. All rights reserved

E-mail [email protected]

USACorbett Robotics Inc185 Berry Street, Suite 5200San Francisco, CA 94107 USAT +1 415 348 1166F +1 415 348 1177

Brisbane AustraliaCorbett Robotics Pty Ltd42 McKechnie DriveEight Mile Plains, QLD 4113T +61 7 3841 7077F +61 7 3841 6077

Web www.corbettlifescience.com

Offices