high quality ˜ high performance brazed plate heat

10
ParaBrazed HIGH QUALITY - HIGH PERFORMANCE BRAZED PLATE HEAT-EXCHANGER THE PARABRAZED PLATE HEAT EXCHANGER IS AN EXTREMELY EFFICIENT AND COMPACT UNIT, ABLE TO PROVIDE GOOD RESULTS IN A NUMBER OF LIQUID / LIQUID SITUATIONS. Ideal for use in: • Cooling and air condition • Heating engineering • Product cooling / warming • Oil heating / cooling • Many other uses Cooling and air condition: • evaporator • condenser • oil cooler • oil heater • economizer • desuperheater Heating engineering: • district heating technology • warm water preparation • floor heating systems • swimming pool engineering Product cooling / Product heating: • chemical industry • coating technology • pharmaceutical industry • process engineering Other uses: • to find out about other uses for ParaBrazed please contact your SPX partner.

Upload: others

Post on 21-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

ParaBrazedH I G H Q UA L I T Y - H I G H P E R F O R M A N C E B R A Z E D P L AT E H E AT-E XC H A N G E R

T H E PA R A B R A Z E D P L AT E H E AT E XC H A N G E R I S A N E XT R E M E LY E F F I C I E N T A N D C O M PACT U N I T, A B L E TO P R OV I D E G O O D R E S U LT S I N A N U M B E R O F L I Q U I D / L I Q U I D S I T UAT I O N S .

Ideal for use in:• Cooling and air condition• Heating engineering • Product cooling / warming• Oil heating / cooling• Many other uses

Cooling and air condition:• evaporator • condenser • oil cooler • oil heater• economizer • desuperheater

Heating engineering:

• district heating technology• warm water preparation• fl oor heating systems• swimming pool engineering

Product cooling / Product heating:• chemical industry• coating technology • pharmaceutical industry• process engineering

Other uses:• to fi nd out about other usesfor ParaBrazed please contact your SPX partner.

Product cooling / Product heating:

Brazing & Material Technology:Copper vs Cu-Free brazingCopper is the industry standard brazing material for brazed plate heat exchangers. There are cases where copper is not suitable for the media fl owing through the system. Some corrosive and acidic fl uids need alternatives such as Nickel brazing materials, which provides a good alternative for the majority of applications.High quality stainless steel is used throughout brazed plate heat exchangers. Depending on the size and model plate thicknesses from 0.25 – 0.6mm in 1.4301 (AISI 304), 1.4401 (AISI 316), 1.4404 (AISI 316L) and 1.4547 (254SMO) are used. For copper brazing a 99.9% pure copper is used.

Quality:The heat exchangers are now ready to be pressure and leak tested in an automated pressure test station. The use of Helium, due to its very small molecule size, which would fi nd any leaks that a larger molecule might not pass through, helps ensure that all exchangers leave the production in perfect condition and according to the European Pressure Equipment Directive (Annex VII of Directive 97/23/EC). Once the test has been successfully completed, a name plate may be attached and the exchanger is free to be released from production and sent to the customer.

Port-HoleSide wallPlate pattern

Contact pointSide wallBrazing material as sealBrazing material at contact point

Design & Function:ParaBrazed plate heat exchangers are designed as strong, compact and effi cient exchangers, maximising heat transfer from one medium to another whilst pre-venting cross-contamination. The labyrinth of plates and narrow channels created within the exchanger create a large heat transfer area with induced turbulence to ensure improved effi ciency with minimum pressure loss. The plate form creates contact points to the next plate and these are used to connect the plates together with the brazing material, providing an extremely strong and stable structure.

Construction:The ParaBrazed range is constructed on a modern auto-mated production line, helping to optimise and guarantee quality at every stage. The process begins with sheet stainless steel on large coils being feed into a high speed press together with brazing material, also fed from reels.

Here the sheet is cut and pressed to form the fl ow channels, portholes and side walls of the individual plate. The plates are then alternately rotated through 180° and stacked to produce the plate pack, as programmed. The endplates and required connectors are fi tted prior to the exchanger being prepared for the oven. Batches of prepa-red heat exchangers are rolled into a vacuum oven, where they are slowly heated during the next 8 hours (depen-ding on the brazing material used) to over 1,000°C before being cooled to room temperature again. It goes without saying that the heat recovered during the cool down stage is used for heating the production and offi ce space. During the heating in the vacuum, the brazing material melts and capillary action helps ensure that the brazing material fl ows into all of the joints and contact points it will seal when cool.

Standard products are normally held on stock or can be built within a short time. A wide range of other sizes is also available.

Options & Tailor-made:For the vast majority of uses, standard heat exchangers are perfect for quick and simple installation and duties. The wide array of ParaBrazed accessories available allow even more flexibility for standard exchangers without the need for modification.

For OEM customers and applications where special demands are present, necessary adaptations can be designed and integrated into the exchanger during production.

Typical variations include different types of connectors (eg. Hydraulic, direct brazing, flange, quick connex, special district hea-ting connections and even without any connections for direct connection to sealed components), sensor housing direct into the porthole for the exact measurement of operational parameters, the addition of mounting studs with internal or external threads, or other brackets and pins as required or construction of compact units in a multi-pass form, bringing the benefits of long thermal lengths into confined spaces. SPX engineers are happy to discuss your exact needs with you to find the right solution, your solution.

Standard product range:

Contact pointSide wallBrazing material as sealBrazing material at contact point

ParaBrazed Product Range

*, *** Type TT4H TTU10H TTU11H TTU20H TT24H TT34M TT35 TT44 TTG45 L/M/H

TT56H TT67H TT88H TT97 L/M/H

CHanneL voLUMe

primary (l) 0.025 0.064 0.073 0.11 0.12 0.16 0.21 0.221 0.31 0.219 0.399 0.6 0.55

secondary (l) 0.025 0.064 0.073 0.11 0.12 0.16 0.21 0.221 0.31 0.219 0.399 0.6 0.7

empty weight (kg) 0.7 + n * 0.05

1.51 + n * 0.112

1.54 + n * 0.112

2.75 + n * 0.187

3 + n * 0.25

4.7 + n * 0.29

8 + n * 0.38

10 + n * 0.54

13.2 + n * 0.5

13.6 + n * 0.43

11.5 + n * 0.8

39.5 + n * 1.25

40 + n * 1.5

oPeRaTinG LiM iTs

Pmax(bar) 30 30 30 30 25 25 25 30 30 25 30 30 25/16**

Temp. (°C) -0/+200 -195/+195 -195/+195 -195/+195 -10/+180 -10/+180 -10/+180 -196/+200 -196/+200 -10/+180 -196/+200 -196/+200 -10/+180

DiMensions

Height (mm) **** A 204 296 334 532 625 613 466 532 543 706 802 875 990

Width (mm) B 74 125 125 125 118 186 256 271 281 296 271 386 365

Con Height (mm) C 170 243 281 479 571 519 380 421 460 583 690 723 861/816**

Con Width (mm) D 40 72 72 72 65 92 170 161 198 180 161 237 214

Plate Pack (mm) L 8 + n * 2.23 9 + n * 2.3 9 + n * 2.3 9 + n * 2.3 7 + n * 2.3 11 + n *

1.7510.5 + n * 2.5

11.5 + n * 2.34

11.5 + n * 2.65

13 + n * 1.4

11.3 + n * 2.31

23 + n * 2.31

10 + n * 2.7

Standard Con Length (mm) F 20 28 28 28 50 52 50 65 37 80 65 90 90

Standard Connection Type G 3/4” G 1” G 1” G 1” G 1” G 2” G 2” G 2 1/2” G 2” DN65

(Comp) G 2 1/2” DN100 DN65/ 100**

Max N° Plates 50 150 150 150 120 200 140 260 160 200 260 360 200

**** volumes, weights and dimensions of finished product may vary slightly

**** Primary side / secondary side

**** other sizes also available with Cu or Cu-Free brazing - please consult your sales partner

**** excluding stands and lifting rings where fitted - download technical drawings for further details

F1

F4

D L F

C A

B

F2

F3

TT97

L/M

/H

TT8

8H

TT67

H

TT56

H

TTG

45L/

M/H

TT44

TT35

TT34

M

TT24

HTT

U20

HTT

U11

HTT

U10

HTT

4H

More information on the ParaConnect product sheet

Connections Removable connections suitable for connection to pipework in weld, thread or braze variations

ParaSelect is available for Android and iOS.

CalculationTogether with the ParaCalc calculation programme, the ParaSelect App is a quick and simple selection tool to help choose the correct exchanger for standard applications on your tablet computer or smart phone.

More information on the ParaMount product sheet

Mounting A variety of stands and brackets to correctly support the heat exchanger

More information on the ParaInsulate product sheet

InsulationCombined or variations for use in hot or cold sys-tems. Meeting current European fi re regulations

More information on the ParaInsulate product sheet

Combined or variations for use in hot or cold sys-tems. Meeting current European fi re regulations

More information on the ParaCIP product sheet

Cleaning & Scale removalHelp ensure optimum operation by keeping plates and channels clear and free of dirt and lime scale

More information on the ParaCIP product sheet

Help ensure optimum operation by keeping plates and channels clear and free of dirt and lime scale

EN

_Par

aBra

zed_

PS_0

7201

4© E

rror

s, O

mis

sion

s an

d Te

chni

cal A

ltera

tions

exc

epte

d Summary:The SPX ParaBrazed plate heat exchanger:• pressure from vacuum up to 30 bar• usable in temperatures -196 °C to +200 °C• high heat transfer coeffi cient• low logarithmic temperature differences• compact design• low weight compared to tubular heat-exchangers• low pressure drop

• good self-cleaning, due to high media velocities• heat transfer surfaces 0.11 – 107.4m²• suitable for parallel use• wide range of fi ttings and accessories• construction for individual applications• use as heat-exchanger, condenser or evaporator

ACCESSORIES & EXTRAS:

A W I D E R A N G E O F AC C E S S O R I E S S U I TA B L E F O R PA R A B R A Z E D A R E AVA I L A B L E TO H E L P W I T H T H E Q U I C K , E A SY A N D P R O F E S S I O N A L S E L E CT I O N , F I T T I N G A N D M A I N T E N A N C E O F T H E E XC H A N G E R .

Full product range:Alongside ParaBrazed, SPX has a wide range of heat exchangers of different forms offering solutions for all heat transfer requirements

REPRESENTATIVE SWEDEN for industr ia l products

C.A. MÖRCK AB

Box 9123, 400 93 Göteborg (Datavägen 23, 436 32 Askim)

+46 31 7202460

[email protected]

Phone:

E:

w: www.ca-morck.se

ParaConnectH I G H Q UA L I T Y, F L E X I B L E R A N G E O F D E TAC H A B L E P I P E C O N N E CT I O N S

S PX OFFE R S A COM PR E H E N S IVE RANG E OF D ETACHAB LE PI PE CON N ECTION S, E NAB LI NG QU ICK, EASY AN D SAFE CON N ECTION TO AN D D I SCON N ECTION FROM TH E SYSTE M. AVAI LAB LE I N ALL COM MON STAN DAR D S, TH E S E CON N ECTION S PROVI D E A G R EAT D EAL OF FLEXI B I LITY ALLOWI NG TH E STAN DAR D TH R EAD CON N ECTION S ON TH E H EAT EXCHANG E R TO B E CONVE RTE D TO WE LD, SOLD E R OR TH R EAD CON N ECTION TO TH E PI PE-N ETWOR K.

TH E US E OF D ETACHAB LE CON N ECTION S ALLOWS FOR S I M PLE R E MOVAL OF TH E EXCHANG E R FROM TH E SYSTE M FOR CLEAR I NG AN D D E-SCALI NG AS WE LL AS R E PLACE M E NT WITH A D I FFE R E NT U N IT, S HOU LD TH E R EQU I R E M E NTS OF TH E SYSTE M B E ALTE R E D I N TH E FUTU R E.

Summary:• Brings a great deal of flexibility to help match the exchanger and pipe work• Standard range from 3/4“ to DN100• Simple and easy to fit

Also suitable for exchangers from other manufactures

Connection Wall MountSimple, compact & professional mounting & connection kit –the system for an installation to be proud of.

Screwing directly onto the four 1“ front exchanger connections the ParaMount WH DN25 provides not only a method of attaching to the wall bracket but is also a rotatable reduction free connection, allowing the pipe work to be fitted flat and tidy against the wall. Should the system require a sensor within one of the flows to or from the exchanger, it is possible to connect to the wall bracket with only three rotatable reduction free connections and screw a sensor into the fourth. With the minimum three connections fitted a weight of up to 30kg can be carried. With all four connections this increases to a maximum of 40kg, depending on the strength of the wall. It is important that the pipework has been designed to prevent expansion and stress and ensures that the pipework is not overstrained before the connection. The connection wall mount is supplied with heavy duty screws and wall plugs, suitable for most wall types, as well as PTFE joint sealing tape.

Connection Wall Mount

DESCRIPTION Heat exchanger connection

End connection Order code

WALL MOUNT CONN. 4 X 1" FOR TTU10/11/20/24 1" external thread 1" external thread TTWMFC-10-11-13

Thread > Thread These brass fittings are supplied in a set of two, including asbestos-free flat seals

Thread > Thread

HEAT EXCHANGER CONNECTION End connection Description Order code

1" EXTERNAL THREAD 1" external threadScrew without reduction 1" (2 pcs/set) TTSWOR-BB

3/4" EXTERNAL THREAD 1/2" external threadScrew for reducing 3/4" to 1/2" (2 pcs/set) TTSR-BX

1" EXTERNAL THREAD 3/4" external threadScrew for reducing 1" to 3/4" (2 pcs/set) TTSR-BA

2" EXTERNAL THREAD 1 1/2" external threadScrew for reducing 2" to 1 1/2" (2 pcs/set) TTSR-ED

2 1/2” EXTERNAL THREAD 2” external threadScrew for reducing 2 1/2” to 2” (2 pcs/set) TTSR-FE

Applications for ParaConnect include: • Domestic and commercial heating and cooling systems• Plant construction• OEM Manufacturers• Uses other than with heat exchangers

EN

_Par

aCon

nect

_PS

_072

01

Err

ors,

Om

issi

ons

and

Tech

nica

l Alte

ratio

ns e

xcep

ted

Thread > Solder These connections have a brass union nut and copper connection piece. Packed in a set of two, the asbestos-free flat seals are included.

Thread > Solder

HEAT EXCHANGER CONNECTION End connection Description Order code

3/4" EXTERNAL THREAD 18mm inner diameterScrew for solder 3/4" - 18 mm (2 pcs/set)

TTSS-A18

1" EXTERNAL THREAD 22mm inner diameterScrew for solder 1" - 22 mm (2 pcs/set)

TTSS-B22

Thread > WeldThe mild steel connection piece is in standard DN sizes to be welded directly to steel pipe-work. Each set of two includes brass union nuts and asbestos-free flat seals.

Compac FlangeThis specially designed flange has been developed to provide the advantages of a standard flange in a compact form that can be used even where there would be not enough space for a standard one. The counter flange is tightened against the O-Ring, integrated in the flange on the exchanger connection, with the effect that a seal can be achieved under much lower tension than a flat seal would require. These flanges are extremely practical on large connections, where the tightening torque for a normal screw connection is high or space to work with a normal screw or standard flange connection is not available. Compac Counter Flanges can be ordered individually in mild or stainless steel.

Thread > Weld

HEAT EXCHANGER CONNECTION End connection Description Order code

3/4" EXTERNAL THREAD 15mm inner diameterScrew for welded connection DN15 (2 pcs/set)

TTSW-DN15

1" EXTERNAL THREAD 20mm inner diameterScrew for welded connection DN20 (2 pcs/set)

TTSW-DN20

2" EXTERNAL THREAD 40mm inner diameterScrew for welded connection DN40 (2 pcs/set)

TTSW-DN40

2 1/2” EXTERNAL THREAD 50mm inner diameterScrew for welded connection DN50 (2 pcs/set)

TTSW-DN50

Compac Flange

HEAT EXCHANGER CONNECTION End connection Description Order code

DN65 COMPAC FLANGE

Compac Counter-Flange DN65

Compac Flange in Stainless Steel DN65/PN40 1.4404

TTFF88S-DN65-PN40

Compac Flange in Mild Steel DN65/PN40 C22.8

TTFF88C-DN65-PN40

DN80 COMPAC FLANGE

Compac Counter-Flange DN80

Compac Flange in Stainless Steel DN80/PN40 1.4404

TTFF88S-DN80-PN40

Compac Flange in Mild Steel DN80/PN40 C22.8

TTFF88C-DN80-PN40

DN100 COMPAC FLANGE

Compac Counter-Flange DN100

Compac Flange in Stainless Steel DN100/PN40 1.4404

TTFF88S-DN100-PN40

Compac Flange in Mild Steel DN100/PN40 C22.8

TTFF88C-DN100-PN40

REPRESENTATIVE SWEDEN for industr ia l products

C.A. MÖRCK AB

Box 9123, 400 93 Göteborg (Datavägen 23, 436 32 Askim)

+46 31 7202460

[email protected]

Phone:

E:

w: www.ca-morck.se

ParaInsulateH I G H Q UA L I T Y - H I G H P E R F O R M A N C E I N S U L AT I O N F O R H E AT E XC H A N G E R S

S PX OFFE R S A COM PR E H E N S IVE RANG E OF I N SU LATION SU ITAB LE FOR US E WITH TH E I R H EAT EXCHANG E R S.H IG H QUALITY I N SU LATION I S NOT ON LY I M PORTANT TO E N SU R E THAT TH E E N E RGY B E I NG TRAN S FE R R E D I N S I D E TH E H EAT EXCHANG E R R E MAI N S I N S I D E TH E H EAT EXCHANG E R - B UT ALSO TO PROTECT EQU I PM E NT, OBJ ECTS AN D PEOPLE FROM COM I NG I NTO CONTACT WITH TH E H EAT EXCHANG E R THAT CAN R EG U LAR LY B E OPE RATI NG AT OVE R 100°C.

Summary:• Helps maximise the efficiency of your heat exchanger• Standard range covers -50°C to +150°C• Simple and easy to fit• Comply with the latest EU fire regulations

• Also available for exchanger from other manufactures• Helps protect from burn / freeze injuries• Customisation for specific requirements possible

PISO SPX pre-insulated ParaBrazed plate heat exchangers provide a single unit capable of being used for both low and high temperature applications. The clean and simple PU foam is moulded directly onto the heat exchanger, producing a vapour-tight seal. This professional solution not only looks nice but also saves on transport and storage of the exchanger and insulation as separate items.

PISO

TECHNICAL DATA

MATERIAL PUR rigid foam

OPERATING TEMPERATURE (°C) -50°C to +150°C (peak / +135°C continuous)

THERMAL CONDUCTIVITY (W/MK) 0.029 W/mK

VAPOUR TRANSMISSION (µ) > 10,000

FIRE CLASS (BASED ON EN 13501) EN 13501 E (DIN 4102-1 B2)

Aluminium Coated This timeless classic remains in high demand, despite the other available options. SPX produces this insulation in a 3 part kit, enabling retrospective fitting - even when the exchanger has already been installed. Customisation and modification of this insulation is possible for ParaBrazed heat exchangers (eg. special feet or mounting bolts). Insulation for the front plate is also available for this insulation.

Aluminium Coated

TECHNICAL DATA 21mm

MATERIAL 21mm PUR rigid foam core (CFC, HCFC & HFC-free) sandwiched in aluminium

OPERATING TEMPERATURE (°C) -35°C to +150°C (peak / +135°C continuous)

THERMAL CONDUCTIVITY (W/MK) 0.0206 W/mK

FIRE CLASS (BASED ON EN 13501) EN 13501 B (DIN 4102-1 B1)

TECHNICAL DATA 50mm

MATERIAL 50mm PUR rigid foam core (CFC, HCFC & HFC-free) sandwiched in aluminium

OPERATING TEMPERATURE (°C) -35°C to +150°C (peak / +135°C continuous)

THERMAL CONDUCTIVITY (W/MK) 0.025 W/mK

FIRE CLASS (BASED ON EN 13501) EN 13501 B (DIN 4102-1 B2)

Rubberised BarrierThis industry standard material can be found in use throughout plant construction. As one of the most effective and cost efficient methods of insulating equipment that is used in temperatures where condensation can build on external surfaces during operation, this material seals, insulates and prevents this problem. SPX rubberised barrier kits are pre-cut, self-adhesive and should be fitted prior to mounting the exchanger.

Rubberised Barrier

TECHNICAL DATA

MATERIAL 10 or 19mm self-adhesive synthetic foam rubber (Elastomer)

OPERATING TEMPERATURE (°C) -50°C to +105°C

THERMAL CONDUCTIVITY (W/MK) 0.033 W/mK

VAPOUR TRANSMISSION (µ) > 10,000

FIRE CLASS (BASED ON EN 13501) EN 13501 B (DIN 4102-1 B1)

Hard Panel

TECHNICAL DATA

MATERIAL 30mm Coated steel sheet and polyester insulation

OPERATING TEMPERATURE (°C) -35°C to +150°C (peak / +135°C continuous)

THERMAL CONDUCTIVITY (W/MK)0.042 W/mK

FIRE CLASS (BASED ON EN 13501) EN 13501 E (DIN 4102-1 B2)

Hard PanelSpecially developed for the ParaBrazed TT97, hard panel insulation is designed specifically for the demands of larger exchangers. The modular construction form provides not only a smart protecting cover for the exchanger but is also easy to pre-install or install on existing exchangers – even in confined spaces.

Applications for ParaInsulate include: • Domestic and commercial heatingand cooling systems

• Plant construction • OEM Manufacturers

• Heat recovery • Protection of equipment andpeople from heat / cold

EN

_Par

aIns

ulat

e_P

S_0

720

14

© E

rror

s, O

mis

sion

s an

d Te

chni

cal A

ltera

tions

exc

epte

d

Hard Shell

TECHNICAL DATA

MATERIAL PUR rigid foam core (CFC, HCFC & HFC-free) in a Polystyrene shell

OPERATING TEMPERATURE (°C) -30°C to +135°C

THERMAL CONDUCTIVITY (W/MK) 0.032 W/mK

FIRE CLASS (BASED ON EN 13501) EN 13501 E (DIN 4102-1 B2)

Hard ShellSPX hard shell insulation is an easy to use 2 part insulation, held together by stainless steel spring clips at either end. This insulation is robust, good looking and easily mounted and removed - even with the heat exchanger in place. This insulation is available for many standard ParaBrazed heat exchangers.

REPRESENTATIVE SWEDEN for industr ia l products

C.A. MÖRCK AB

Box 9123, 400 93 Göteborg (Datavägen 23, 436 32 Askim)

+46 31 7202460

[email protected]

Phone:

E:

w: www.ca-morck.se

ParaMountH I G H Q UA L I T Y, F L E X I B L E R A N G E O F H E AT E XC H A N G E R M O U N T S

S PX OFFE R S A COM PR E H E N S IVE RANG E OF MOU NTI NG OPTION S FOR H EAT EXCHANG E R S - NOT ON LY TO E N SU R E THAT TH E EXCHANG E R I S SU PPORTE D I N A STAB LE, SAFE AN D S ECU R E WAY B UT ALSO R E D UCE S U N N ECE SSARY STRAI N AN D STR E SS ON TH E PI PE S AN D PARTS I N TH E SYSTE M. AD D ITIONALLY TH E COR R ECT MOU NTI NG PROVI D E S A N EAT, E FFECTIVE AN D PROFE SS IONAL S ETTI NG FOR TH I S VITAL COM PON E NT WITH I N TH E HYD RAU LIC SYSTE M. TH E CON N ECTION WALL MOU NT S I M PLI FI E S FITTI NG TH E EXCHANG E R EVE N FU RTH E R BY I NTEG RATI NG FR E E-FLOW R IG HT ANG LE ROTATAB LE CON N ECTION S.

Summary:• Stable, safe and secure mounting• Reduction of strain and stress on pipes and components• Simple and easy to fit• Neat, effective and professional• Versions for exchangers with or without insulation• Also suitable for exchangers from other manufactures

Connection Wall Mount Simple, compact & professional mounting & connection kit – the system for an installation to be proud of.

Screwing directly onto the four 1“ front exchanger connections the ParaMount WH DN25 provides not only a method of attaching to the wall bracket but is also a rotatable reduction free connection, allowing the pipe work to be fitted flat and tidy against the wall.

Should the system require a sensor within one of the flows to or from the exchanger, it is possible to connect to the wall bracket with only three rotatable reduction free connections and screw a sensor into the fourth.

With the minimum three connections fitted a weight of up to 30kg can be carried. With all four connections this increases to a maximum of 40kg, depending on the strength of the wall.

It is important that the pipework has been designed to prevent expansion and stress and ensures that the pipework is not overstrained before the connection.

The connection wall mount is supplied with heavy duty screws and wall plugs, suitable for most wall types, as well as PTFE joint sealing tape.

Connection Wall Mount

DESCRIPTION Heat exchanger connection End connection Order code

WALL MOUNT CONN. 4 X 1" FOR TTU10/11/20/24 1" external thread 1" external thread TTWMFC-10-11-13

Applications for ParaMount include: • Domestic and commercial heating and cooling systems• Plant construction• OEM Manufacturers• Heat recovery

EN

_Par

aMou

nt_P

S_0

720

14

© E

rror

s, O

mis

sion

s an

d Te

chni

cal A

ltera

tions

exc

epte

d

Wall Bracket These steel L brackets are designed to provide a simple method of supporting the weight of small heat exchangers with their connections facing away from the wall. Supplied with basic screws and wall plugs, the exchanger (with or without insulation) is secured to the bracket using a cable binder.

Floor Stand The robust floor stand is constructed from steel brackets connected together with threaded bars to ensure optimum flexibility when being assembled to cradle the heat exchanger – with or without insulation. The pre-drilled fixing holes also allow for the stand to be fixed to the floor for maximum stability.

Wall Bracket

DESCRIPTION Size Max. exchanger size Order code

WALL MOUNT FOR TTU4/10/11/13 305mm x 115mm x 40mm Upto 40 plates TTWMFU-10-11-13

WALL MOUNT FOR TTU20/24 455mm x 115mm x 40mm Upto 40 plates TTWMFU-20-24

Floor Stand

DESCRIPTION Size Height to cradle cup Order code

FLOOR STAND FOR TT24 UPTO 80 PLATES, UNINSULATED 124mm x 155mm x 122mm 121mm TTFB24UT-80-UISO

FLOOR STAND FOR TT24 UPTO 160 PLATES, UNINSULATED 124mm x 155mm x 267mm 121mm TTFB24UT-160-UISO

FLOOR STAND FOR TT24 UPTO 80 PLATES, INSULATED 174mm x 155mm x 122mm 121mm TTFB24UT-80-ISO

FLOOR STAND FOR TT24 UPTO 160 PLATES, INSULATED 174mm x 155mm x 267mm 121mm TTFB24UT-160-ISO

FLOOR STAND FOR TTG45 UPTO 80 PLATES, UNINSULATED 287mm x 155mm x 122mm 121mm TTFB45UT-80-UISO

FLOOR STAND FOR TTG45 UPTO 160 PLATES, UNINSULATED 287mm x 155mm x 267mm 121mm TTFB45UT-160-UISO

FLOOR STAND FOR TTG45 UPTO 80 PLATES, INSULATED 337mm x 155mm x 122mm 121mm TTFB45UT-80-ISO

FLOOR STAND FOR TTG45 UPTO 160 PLATES, INSULATED 337mm x 155mm x 267mm 121mm TTFB45UT-160-ISO

with their connections facing away from the wall. Supplied with basic screws and wall plugs, the exchanger

flexibility when being assembled to cradle the heat exchanger – with or without insulation. The pre-drilled fixing holes also allow for the stand to be fixed to the floor for maximum stability.

REPRESENTATIVE SWEDEN : CAMpreq AB

Box 9123, 400 93 Göteborg (Datavägen 23, 436 32 Askim)

+46 31 7202460

[email protected]

Phone:

E:

www.campreq.seW: