heaven properties, llc now or betty anne camp teague...

1
JIAYUAN, LLC NOW OR FORMERLY PART OF LOT 15-18 DB 31455 PG 95 MB 4 PG 163 TAX # 061-222-18 ZONING: O-1 (CD) USE: RESTAURANT LQ CHARLOTTE, LLC NOW OR FORMERLY LOT 1 DB 21171 PG 893 MB 46 PG 781 TAX # 061-222-07 ZONING: O-1 (CD) USE: HOTEL HEAVEN PROPERTIES, LLC NOW OR FORMERLY LOT 7 DB 32949 PG 380 MB 4 PG 163 TAX # 061-222-06 ZONING: R17-MF USE: VACANT BETTY ANNE CAMP TEAGUE NOW OR FORMERLY PART OF LOT 19 DB 905 PG 210 MB 4 PG 163 TAX # 061-222-23 ZONING: R17-MF USE: VACANT X X X X X X X X X X X X X X X X X X OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP 27" CANOPY TREE 24" OAK 30" OAK 27" CANOPY TREE 24" TREE (DEAD) 10" DBL CANOPY TREE 8" CANOPY TREE 36" OAK 30" OAK 12" CANOPY TREE 60' 5' 8.73' 9' 18' 11.1' 8.23' 5' 18' 9' 24' 5' 8' 7' 22' 5' 5' SIDE SETBACK 20' FRONT SETBACK 5' SIDE SETBACK 20' FRONT SETBACK 8 8 19 7 4 11 8 7 3 PROPOSED HOTEL 72 ROOMS PROPOSED PARKING: 75 SPACES SLOAN DRIVE 40' PUBLIC R/W PER MB 46 PG 781 PROPERTY LINE PROPERTY LINE MULBERRY CHURCH ROAD VARIABLE R/W PER MECKLENBURG COUNTY G CDOT MAINTAINS NO PUBLIC PLAN OF RECOR (40' PUBLIC R/W PER MB 46 PG 781) DUMPSTER / RECYCLING ENCLOSURE PROPOSED MODIFIED TYPE II DRIVEWAY PROPOSED MODIFIED TYPE II DRIVEWAY OVERHEAD CANOPY 6' SIDEWALK 8' PLANTING STRIP 6' SIDEWALK 8' PLANTING STRIP STREET TREE, TYP. STREET TREE, TYP. 31' TREE SAVE 46' CLASS 'B' BUFFER 34.5' CLASS 'B' BUFFER (25% REDUCTION WITH FENCE) 24' 24' EXISTING TREE, TO REMAIN EXISTING TREE, TO REMAIN EXISTING TREE TO BE REMOVED, TYP. SITE SLOAN DRIVE MULBERRY CHURCH ROAD QUEEN CITY DRIVE FORESTBROOK DRIVE TACOMA STREET DEVELOPMENT AREA SLOAN DRIVE MULBERRY CHURCH ROAD JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BY DATE DRAWN BY DATE REVISION DESCRIPTION YOUR VISION ACHIEVED THROUGH OURS. These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. 610 E. Morehead Street, Suite 250 | Charlotte, NC 28202 TEL 704.602.8600 FAX 704.376.1076 www.timmons.com North Carolina License No. C-1652 THIS DRAWING PREPARED AT THE CHARLOTTE OFFICE R:\104\43700-Sloan_Drive_Hotel\DWG\Sheet\Exhibit\43700-Rezoning.dwg | Plotted on 9/4/2019 9:02 AM | by Jason Dolan RZ-100 REZONING PLAN ALR BVC BVC 09/03/19 SLOAN DRIVE HOTEL MECKLENBURG COUNTY, NORTH CAROLINA 43700 AS SHOWN NAD 83 0 SCALE 1"=20' 40' 20' VICINITY MAP 1" = 300' REZONING PETITION NO. 2019-XXX REZONING SUMMARY PETITIONER : AMMIREDDY LLC 457 WILCOX STREET CHARLOTTE, NC 28203 REZONING SITE AREA: 1.89 ACRES TAX PARCEL #: 06122233 EXISTING ZONING: O-1 (CD) #1995-87 PROPOSED ZONING: O-1 (CD) SPA EXISTING USES: VACANT PROPOSED USES: HOTEL MAX. BUILDING HEIGHT: 50' (3 STORIES) MAX. GROSS SQUARE FOOTAGE: 35,000 SF PARKING: REQ. PARKING: 1 SPACE PER ROOM X 72 ROOMS = 72 SPACES PROVIDED PARKING: STANDARD: 72 SPACES ACCESSIBLE: 3 SPACES TOTAL: 75 SPACES TREE SAVE: REQUIRED: 0.28 AC (15%) PROVIDED: 0.28 AC MINIMUM GENERAL PROVISIONS: a. SITE LOCATION. THESE DEVELOPMENT STANDARDS FORM A PART OF THE REZONING PLAN ASSOCIATED WITH THE REZONING PETITION FILED BY AMMIREDDY, LLC (“PETITIONER”) TO ACCOMMODATE THE DEVELOPMENT OF A HOTEL AS ALLOWED IN THE O-1 ZONING DISTRICT ON APPROXIMATELY 1.89 ACRE SITE LOCATED BETWEEN SLOAN DRIVE AND MULBERRY CHURCH ROAD (THE "SITE"). b. ZONING DISTRICTS/ORDINANCE. DEVELOPMENT OF THE SITE WILL BE GOVERNED BY THE REZONING PLAN AS WELL AS THE APPLICABLE PROVISIONS OF THE CITY OF CHARLOTTE ZONING ORDINANCE (THE “ORDINANCE”). UNLESS THE REZONING PLAN ESTABLISHES MORE STRINGENT STANDARDS THE REGULATIONS ESTABLISHED UNDER THE ORDINANCE FOR THE NS ZONING CLASSIFICATION SHALL GOVERN. c. GRAPHICS AND ALTERATIONS. THE SCHEMATIC DEPICTIONS OF THE USES, PARKING AREAS, SIDEWALKS, STRUCTURES AND BUILDINGS, DRIVEWAYS, AND OTHER DEVELOPMENT MATTERS AND SITE ELEMENTS (COLLECTIVELY THE “DEVELOPMENT/SITE ELEMENTS”) SET FORTH ON THE REZONING PLAN SHOULD BE REVIEWED IN CONJUNCTION WITH THE PROVISIONS OF THESE DEVELOPMENT STANDARDS. THE LAYOUT, LOCATIONS, SIZES AND FORMULATIONS OF THE DEVELOPMENT/SITE ELEMENTS DEPICTED ON THE REZONING PLAN ARE GRAPHIC REPRESENTATIONS OF THE DEVELOPMENT/SITE ELEMENTS PROPOSED. CHANGES TO THE REZONING PLAN NOT ANTICIPATED BY THE REZONING PLAN WILL BE REVIEWED AND APPROVED AS ALLOWED BY SECTION 6.207 OF THE ORDINANCE. d. NUMBER OF BUILDINGS PRINCIPAL AND ACCESSORY. THE TOTAL NUMBER OF PRINCIPAL BUILDINGS TO BE DEVELOPED ON THE SITE SHALL NOT EXCEED ONE (1). ACCESSORY BUILDINGS AND STRUCTURES LOCATED ON THE SITE SHALL NOT BE CONSIDERED IN ANY LIMITATION ON THE NUMBER OF BUILDINGS ON THE SITE. ACCESSORY BUILDINGS AND STRUCTURES WILL BE CONSTRUCTED UTILIZING SIMILAR BUILDING MATERIALS, ARCHITECTURAL ELEMENTS AND DESIGNS AS THE PRINCIPAL BUILDINGS LOCATED ON THE SITE. 2. PERMITTED USES & DEVELOPMENT AREA LIMITATION: a. WITHIN DEVELOPMENT AREA UP TO 80 ROOMS FOR HOTEL USE AS ALLOWED IN THE O-1 ZONING DISTRICT MAY BE DEVELOPED. FOR PURPOSES OF THE DEVELOPMENT LIMITATIONS SET FORTH IN THESE DEVELOPMENT STANDARDS FOR THIS PETITION (BUT NOT TO BE CONSTRUED AS A LIMITATION ON FAR REQUIREMENTS OR DEFINITION SET BY THE ORDINANCE), THE FOLLOWING ITEMS WILL NOT BE COUNTED AS PART OF THE ALLOWED GROSS FLOOR AREA (FLOOR AREA AS DEFINED BY THE ORDINANCE) FOR THE SITE: SURFACE PARKING FACILITIES, AND ALL LOADING DOCK AREAS (OPEN OR ENCLOSED). 3. ACCESS AND TRANSPORTATION: a. ACCESS TO THE SITE WILL BE FROM SLOAN DRIVE AND MULBERRY CHURCH ROAD IN THE MANNER GENERALLY DEPICTED ON THE REZONING PLAN. b. THE PLACEMENT AND CONFIGURATION OF THE VEHICULAR ACCESS POINTS ARE SUBJECT TO ANY MINOR MODIFICATIONS REQUIRED TO ACCOMMODATE FINAL SITE DEVELOPMENT AND CONSTRUCTION PLANS AND TO ANY ADJUSTMENTS REQUIRED FOR APPROVAL BY CDOT AND/OR NCDOT IN ACCORDANCE WITH APPLICABLE PUBLISHED STANDARDS. c. THE PETITIONER WILL PROVIDE A TWO (2) FOOT UTILITY EASEMENT BEHIND THE SIDEWALK IF RIGHT-OF-WAY IS CLOSER THAN TWO (2) FEET BEHIND THE SIDEWALK. d. THE ALIGNMENT OF THE INTERNAL VEHICULAR CIRCULATION AND DRIVEWAYS MAY BE MODIFIED BY THE PETITIONER TO ACCOMMODATE CHANGES IN TRAFFIC PATTERNS, PARKING LAYOUTS AND ANY ADJUSTMENTS REQUIRED FOR APPROVAL BY CDOT AND/OR NCDOT IN ACCORDANCE WITH PUBLISHED STANDARDS. 4. STREETSCAPE, BUFFERS, YARDS AND LANDSCAPING: a. ALONG THE SITE'S NORTHERN PROPERTY BOUNDARY A 46 FOOT WIDE LANDSCAPE AREA PLANTED TO CLASS B BUFFER STANDARDS WILL BE PROVIDED. THE BUFFER WIDTH MAY BE REDUCED BY 25% WITH THE CONSTRUCTION OF A FENCE OR WALL ACCORDING TO SECTION 12.302 (8). b. THE PETITIONER WILL PROVIDE A SIDEWALK NETWORK THAT LINKS THE PROPOSED BUILDING ENTRANCES TO THE SIDEWALK ALONG SLOAN DRIVE AND MULBERRY CHURCH ROAD. THE MINIMUM WIDTH FOR THIS INTERNAL SIDEWALK WILL BE FIVE (5) FEET. c. ABOVE-GROUND BACKFLOW PREVENTION DEVICES WILL BE SCREENED FROM PUBLIC VIEW AND WILL BE LOCATED OUTSIDE OF THE REQUIRED SETBACKS. d. DUMPSTER AREAS AND RECYCLING AREAS WILL BE ENCLOSED BY A SOLID WALL AND GATE. THE WALL USED TO ENCLOSE THE DUMPSTER WILL BE ARCHITECTURALLY COMPATIBLE WITH THE BUILDING MATERIALS AND COLORS USED ON THE PRINCIPAL BUILDING. e. ALL NEW TREES AT TIME OF PLANTING SHALL HAVE A CALIPER OF 2"-3" AND A HEIGHT OF 10'-12'. f. FOUNDATION PLANTING/PERIMETER PLANTING TO BE MIXED SHRUBS AND GROUNDCOVER (JUNIPER, HOLLY, COTONEASTER, LIRIOPE). g. PARKING AREAS SHALL BE SCREENED IN ACCORDANCE WITH CURRENT ZONING ORDINANCE. 5. ARCHITECTURAL STANDARDS: a. BUILDINGS SHOULD BE A MINIMUM HEIGHT OF 50 FEET. 6. ENVIRONMENTAL FEATURES: a. THE PETITIONER SHALL COMPLY WITH THE CHARLOTTE CITY COUNCIL APPROVED AND ADOPTED POST CONSTRUCTION ORDINANCE. b. THE LOCATION, SIZE, AND TYPE OF STORM WATER MANAGEMENT SYSTEMS DEPICTED ON THE REZONING PLAN ARE SUBJECT TO REVIEW AND APPROVAL AS PART OF THE FULL DEVELOPMENT PLAN SUBMITTAL AND ARE NOT IMPLICITLY APPROVED WITH THIS REZONING. ADJUSTMENTS MAY BE NECESSARY IN ORDER TO ACCOMMODATE ACTUAL STORM WATER TREATMENT REQUIREMENTS AND NATURAL SITE DISCHARGE POINTS. c. THE SITE WILL COMPLY WITH THE TREE ORDINANCE. d. ALL EXISTING TREES/VEGETATION OUTSIDE DESIGNATED DEVELOPMENT AREA TO REMAIN. 7. LIGHTING: a. ALL NEW DETACHED AND ATTACHED LIGHTING SHALL BE FULL CUT-OFF TYPE LIGHTING FIXTURES EXCLUDING LOWER, DECORATIVE LIGHTING THAT MAY BE INSTALLED ALONG THE DRIVEWAYS, SIDEWALKS, AND PARKING AREAS. b. DETACHED LIGHTING WILL BE LIMITED TO 20 FEET IN HEIGHT. 8. AMENDMENTS TO THE REZONING PLAN: a. FUTURE AMENDMENTS TO THE REZONING PLAN (WHICH INCLUDES THESE DEVELOPMENT STANDARDS) MAY BE APPLIED FOR BY THE THEN OWNER OR OWNERS OF THE PORTION OF THE SITE AFFECTED BY SUCH AMENDMENT IN ACCORDANCE WITH THE PROVISIONS OF CHAPTER 6 OF THE ORDINANCE. 9. BINDING EFFECT OF THE REZONING APPLICATION: a. IF THIS REZONING PETITION IS APPROVED, ALL CONDITIONS APPLICABLE TO THE DEVELOPMENT OF THE SITE IMPOSED UNDER THE REZONING PLAN WILL, UNLESS AMENDED IN THE MANNER PROVIDED UNDER THE ORDINANCE, BE BINDING UPON AND INURE TO THE BENEFIT OF THE PETITIONER AND SUBSEQUENT OWNERS OF THE SITE AND THEIR RESPECTIVE HEIRS, DEVISEES, PERSONAL REPRESENTATIVES, SUCCESSORS IN INTEREST OR ASSIGNS. DEVELOPMENT AREA MAP 1" = 100'

Upload: others

Post on 25-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEAVEN PROPERTIES, LLC NOW OR BETTY ANNE CAMP TEAGUE …ww.charmeck.org/Planning/Rezoning/2019/122-137/2019... · tax # 061-222-07 zoning: o-1 (cd) use: hotel heaven properties, llc

JIAYUAN, LLC

NOW OR FORMERLY PART OF LOT 15-18

DB 31455 PG 95

MB 4 PG 163

TAX # 061-222-18

ZONING: O-1 (CD)

USE: RESTAURANT

LQ CHARLOTTE, LLC

NOW OR FORMERLY LOT 1

DB 21171 PG 893

MB 46 PG 781

TAX # 061-222-07

ZONING: O-1 (CD)

USE: HOTEL

HEAVEN PROPERTIES, LLC NOW OR

FORMERLY LOT 7

DB 32949 PG 380

MB 4 PG 163

TAX # 061-222-06

ZONING: R17-MF

USE: VACANT

BETTY ANNE CAMP TEAGUE NOW OR

FORMERLY PART OF LOT 19

DB 905 PG 210

MB 4 PG 163

TAX # 061-222-23

ZONING: R17-MF

USE: VACANT

X X X X X X X X X X X X X X X X X X

OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP

27" CANOPY

TREE

24" OAK

30" OAK

27" CANOPY

TREE

24" TREE

(DEAD)

10" DBL

CANOPY TREE

8" CANOPY

TREE

36" OAK

30" OAK

12" CANOPY

TREE

60'

5'

8.73'

9'

18'

11.1'

8.23'5'

18'

9'

24'

5'

8'

7'

22'

5'

5' SIDE

SETBACK

20'

FRONT

SETBACK

5' SIDE

SETBACK

20'

FRONT

SETBACK

88

19

7

4

11

8

7

3

PROPOSED HOTEL

72 ROOMS

PROPOSED PARKING: 75 SPACES

S

L

O

A

N

D

R

IV

E

4

0

' P

U

B

L

IC

R

/W

P

E

R

M

B

4

6

P

G

7

8

1

PROPERTY LINE

PROPERTY LINE

MU

LB

ER

RY

C

HU

RC

H R

OA

D

VA

RIA

BLE

R

/W

P

ER

M

EC

KLE

NB

UR

G C

OU

NT

Y G

IS

CD

OT

M

AIN

TA

IN

S N

O P

UB

LIC

P

LA

N O

F R

EC

OR

D

(40' P

UB

LIC

R

/W

P

ER

M

B 46 P

G 781)

DUMPSTER / RECYCLING

ENCLOSURE

PROPOSED

MODIFIED

TYPE II

DRIVEWAY

PROPOSED

MODIFIED TYPE II

DRIVEWAY

OVERHEAD CANOPY

6' SIDEWALK

8' PLANTING

STRIP

6' SIDEWALK

8' PLANTING

STRIP

STREET

TREE, TYP.

STREET

TREE, TYP.

31'

TREE

SAVE

46' CLASS 'B' BUFFER

34.5' CLASS 'B' BUFFER (25% REDUCTION WITH FENCE)

24'24'

EXISTING TREE,

TO REMAIN

EXISTING TREE,

TO REMAIN

EXISTING TREE TO

BE REMOVED, TYP.

SITE

S

L

O

A

N

D

R

I

V

E

M

U

L

B

E

R

R

Y

C

H

U

R

C

H

R

O

A

D

QUEEN CITY DRIVE

F

O

R

E

S

T

B

R

O

O

K

D

R

IV

E

TA

CO

MA

S

TR

EE

T

DEVELOPMENT AREA

SL

OA

N D

RIV

E

MU

LB

ER

RY

C

HU

RC

H R

OA

D

JOB NO.

SHEET NO.

SCALE

DESIGNED BY

CHECKED BY

DATE

DRAWN BY

DATE

REVISIO

N D

ESCRIPTIO

N

YO

UR VISIO

N ACH

IEVED

TH

RO

UG

H O

URS.

These plans and associated docum

ents are the exclusive property of T

IM

MO

NS

G

RO

UP

and m

ay not be reproduced in w

hole or in part and shall not be used for any purpose w

hatsoever, inclusive, but not

lim

ited to construction, bidding, and/or construction staking w

ithout the express w

ritten consent of T

IM

MO

NS

G

RO

UP

.

610 E. M

orehead Street, Suite 250 | Charlotte, N

C 28202

TEL 704.602.8600 FAX 704.376.1076 w

ww

.tim

mons.com

North Carolina License N

o. C-1652

TH

IS D

RAW

IN

G PREPARED

AT TH

E

CH

AR

LO

TTE O

FFIC

E

R:\104\43700-S

loan_D

rive_H

otel\D

WG

\S

heet\E

xhibit\43700-R

ezoning.dw

g | P

lotted on 9/4/2019 9:02 A

M | by Jason D

olan

RZ-100

REZO

NIN

G PLAN

ALR

BVC

BVC

09/03/19

SLO

AN

D

RIVE H

OTEL

MECKLEN

BU

RG

CO

UN

TY, N

ORTH

CARO

LIN

A

43700

AS SHOWN

NA

D 8

3

0

SCALE 1"=20'

40'20'

VICINITY MAP

1" = 300'

REZONING PETITION NO. 2019-XXX

REZONING SUMMARY

PETITIONER : AMMIREDDY LLC

457 WILCOX STREET

CHARLOTTE, NC 28203

REZONING SITE AREA: 1.89 ACRES

TAX PARCEL #: 06122233

EXISTING ZONING: O-1 (CD) #1995-87

PROPOSED ZONING: O-1 (CD) SPA

EXISTING USES: VACANT

PROPOSED USES: HOTEL

MAX. BUILDING HEIGHT: 50' (3 STORIES)

MAX. GROSS SQUARE FOOTAGE: 35,000 SF

PARKING:

REQ. PARKING: 1 SPACE PER ROOM X 72 ROOMS

= 72 SPACES

PROVIDED PARKING:

STANDARD: 72 SPACES

ACCESSIBLE: 3 SPACES

TOTAL: 75 SPACES

TREE SAVE:

REQUIRED: 0.28 AC (15%)

PROVIDED: 0.28 AC MINIMUM

GENERAL PROVISIONS:

a. SITE LOCATION. THESE DEVELOPMENT STANDARDS FORM A PART OF THE REZONING PLAN ASSOCIATED WITHTHE REZONING PETITION FILED BY AMMIREDDY, LLC (“PETITIONER”) TO ACCOMMODATE THE DEVELOPMENT OF AHOTEL AS ALLOWED IN THE O-1 ZONING DISTRICT ON APPROXIMATELY 1.89 ACRE SITE LOCATED BETWEEN SLOANDRIVE AND MULBERRY CHURCH ROAD (THE "SITE").

b. ZONING DISTRICTS/ORDINANCE. DEVELOPMENT OF THE SITE WILL BE GOVERNED BY THE REZONING PLAN ASWELL AS THE APPLICABLE PROVISIONS OF THE CITY OF CHARLOTTE ZONING ORDINANCE (THE “ORDINANCE”). UNLESSTHE REZONING PLAN ESTABLISHES MORE STRINGENT STANDARDS THE REGULATIONS ESTABLISHED UNDER THEORDINANCE FOR THE NS ZONING CLASSIFICATION SHALL GOVERN.

c. GRAPHICS AND ALTERATIONS. THE SCHEMATIC DEPICTIONS OF THE USES, PARKING AREAS, SIDEWALKS,STRUCTURES AND BUILDINGS, DRIVEWAYS, AND OTHER DEVELOPMENT MATTERS AND SITE ELEMENTS(COLLECTIVELY THE “DEVELOPMENT/SITE ELEMENTS”) SET FORTH ON THE REZONING PLAN SHOULD BE REVIEWED INCONJUNCTION WITH THE PROVISIONS OF THESE DEVELOPMENT STANDARDS. THE LAYOUT, LOCATIONS, SIZES ANDFORMULATIONS OF THE DEVELOPMENT/SITE ELEMENTS DEPICTED ON THE REZONING PLAN ARE GRAPHICREPRESENTATIONS OF THE DEVELOPMENT/SITE ELEMENTS PROPOSED. CHANGES TO THE REZONING PLAN NOTANTICIPATED BY THE REZONING PLAN WILL BE REVIEWED AND APPROVED AS ALLOWED BY SECTION 6.207 OF THEORDINANCE.

d. NUMBER OF BUILDINGS PRINCIPAL AND ACCESSORY. THE TOTAL NUMBER OF PRINCIPAL BUILDINGS TO BEDEVELOPED ON THE SITE SHALL NOT EXCEED ONE (1). ACCESSORY BUILDINGS AND STRUCTURES LOCATED ON THESITE SHALL NOT BE CONSIDERED IN ANY LIMITATION ON THE NUMBER OF BUILDINGS ON THE SITE. ACCESSORYBUILDINGS AND STRUCTURES WILL BE CONSTRUCTED UTILIZING SIMILAR BUILDING MATERIALS, ARCHITECTURALELEMENTS AND DESIGNS AS THE PRINCIPAL BUILDINGS LOCATED ON THE SITE.

2. PERMITTED USES & DEVELOPMENT AREA LIMITATION:

a. WITHIN DEVELOPMENT AREA UP TO 80 ROOMS FOR HOTEL USE AS ALLOWED IN THE O-1 ZONING DISTRICT MAYBE DEVELOPED.

FOR PURPOSES OF THE DEVELOPMENT LIMITATIONS SET FORTH IN THESE DEVELOPMENT STANDARDS FOR THIS PETITION(BUT NOT TO BE CONSTRUED AS A LIMITATION ON FAR REQUIREMENTS OR DEFINITION SET BY THE ORDINANCE), THEFOLLOWING ITEMS WILL NOT BE COUNTED AS PART OF THE ALLOWED GROSS FLOOR AREA (FLOOR AREA AS DEFINED BYTHE ORDINANCE) FOR THE SITE: SURFACE PARKING FACILITIES, AND ALL LOADING DOCK AREAS (OPEN OR ENCLOSED).

3. ACCESS AND TRANSPORTATION:

a. ACCESS TO THE SITE WILL BE FROM SLOAN DRIVE AND MULBERRY CHURCH ROAD IN THE MANNER GENERALLYDEPICTED ON THE REZONING PLAN.

b. THE PLACEMENT AND CONFIGURATION OF THE VEHICULAR ACCESS POINTS ARE SUBJECT TO ANY MINORMODIFICATIONS REQUIRED TO ACCOMMODATE FINAL SITE DEVELOPMENT AND CONSTRUCTION PLANS AND TO ANYADJUSTMENTS REQUIRED FOR APPROVAL BY CDOT AND/OR NCDOT IN ACCORDANCE WITH APPLICABLE PUBLISHEDSTANDARDS.

c. THE PETITIONER WILL PROVIDE A TWO (2) FOOT UTILITY EASEMENT BEHIND THE SIDEWALK IF RIGHT-OF-WAY ISCLOSER THAN TWO (2) FEET BEHIND THE SIDEWALK.

d. THE ALIGNMENT OF THE INTERNAL VEHICULAR CIRCULATION AND DRIVEWAYS MAY BE MODIFIED BY THEPETITIONER TO ACCOMMODATE CHANGES IN TRAFFIC PATTERNS, PARKING LAYOUTS AND ANY ADJUSTMENTSREQUIRED FOR APPROVAL BY CDOT AND/OR NCDOT IN ACCORDANCE WITH PUBLISHED STANDARDS.

4. STREETSCAPE, BUFFERS, YARDS AND LANDSCAPING:

a. ALONG THE SITE'S NORTHERN PROPERTY BOUNDARY A 46 FOOT WIDE LANDSCAPE AREA PLANTED TO CLASS BBUFFER STANDARDS WILL BE PROVIDED. THE BUFFER WIDTH MAY BE REDUCED BY 25% WITH THE CONSTRUCTION OFA FENCE OR WALL ACCORDING TO SECTION 12.302 (8).

b. THE PETITIONER WILL PROVIDE A SIDEWALK NETWORK THAT LINKS THE PROPOSED BUILDING ENTRANCES TOTHE SIDEWALK ALONG SLOAN DRIVE AND MULBERRY CHURCH ROAD. THE MINIMUM WIDTH FOR THIS INTERNALSIDEWALK WILL BE FIVE (5) FEET.

c. ABOVE-GROUND BACKFLOW PREVENTION DEVICES WILL BE SCREENED FROM PUBLIC VIEW AND WILL BELOCATED OUTSIDE OF THE REQUIRED SETBACKS.

d. DUMPSTER AREAS AND RECYCLING AREAS WILL BE ENCLOSED BY A SOLID WALL AND GATE. THE WALL USED TOENCLOSE THE DUMPSTER WILL BE ARCHITECTURALLY COMPATIBLE WITH THE BUILDING MATERIALS AND COLORSUSED ON THE PRINCIPAL BUILDING.

e. ALL NEW TREES AT TIME OF PLANTING SHALL HAVE A CALIPER OF 2"-3" AND A HEIGHT OF 10'-12'.

f. FOUNDATION PLANTING/PERIMETER PLANTING TO BE MIXED SHRUBS AND GROUNDCOVER (JUNIPER, HOLLY,COTONEASTER, LIRIOPE).

g. PARKING AREAS SHALL BE SCREENED IN ACCORDANCE WITH CURRENT ZONING ORDINANCE.

5. ARCHITECTURAL STANDARDS:

a. BUILDINGS SHOULD BE A MINIMUM HEIGHT OF 50 FEET.

6. ENVIRONMENTAL FEATURES:

a. THE PETITIONER SHALL COMPLY WITH THE CHARLOTTE CITY COUNCIL APPROVED AND ADOPTED POSTCONSTRUCTION ORDINANCE.

b. THE LOCATION, SIZE, AND TYPE OF STORM WATER MANAGEMENT SYSTEMS DEPICTED ON THE REZONING PLANARE SUBJECT TO REVIEW AND APPROVAL AS PART OF THE FULL DEVELOPMENT PLAN SUBMITTAL AND ARE NOTIMPLICITLY APPROVED WITH THIS REZONING. ADJUSTMENTS MAY BE NECESSARY IN ORDER TO ACCOMMODATEACTUAL STORM WATER TREATMENT REQUIREMENTS AND NATURAL SITE DISCHARGE POINTS.

c. THE SITE WILL COMPLY WITH THE TREE ORDINANCE.

d. ALL EXISTING TREES/VEGETATION OUTSIDE DESIGNATED DEVELOPMENT AREA TO REMAIN.

7. LIGHTING:

a. ALL NEW DETACHED AND ATTACHED LIGHTING SHALL BE FULL CUT-OFF TYPE LIGHTING FIXTURES EXCLUDINGLOWER, DECORATIVE LIGHTING THAT MAY BE INSTALLED ALONG THE DRIVEWAYS, SIDEWALKS, AND PARKINGAREAS.

b. DETACHED LIGHTING WILL BE LIMITED TO 20 FEET IN HEIGHT.

8. AMENDMENTS TO THE REZONING PLAN:

a. FUTURE AMENDMENTS TO THE REZONING PLAN (WHICH INCLUDES THESE DEVELOPMENT STANDARDS) MAY BEAPPLIED FOR BY THE THEN OWNER OR OWNERS OF THE PORTION OF THE SITE AFFECTED BY SUCH AMENDMENT INACCORDANCE WITH THE PROVISIONS OF CHAPTER 6 OF THE ORDINANCE.

9. BINDING EFFECT OF THE REZONING APPLICATION:

a. IF THIS REZONING PETITION IS APPROVED, ALL CONDITIONS APPLICABLE TO THE DEVELOPMENT OF THE SITEIMPOSED UNDER THE REZONING PLAN WILL, UNLESS AMENDED IN THE MANNER PROVIDED UNDER THE ORDINANCE,BE BINDING UPON AND INURE TO THE BENEFIT OF THE PETITIONER AND SUBSEQUENT OWNERS OF THE SITE AND THEIRRESPECTIVE HEIRS, DEVISEES, PERSONAL REPRESENTATIVES, SUCCESSORS IN INTEREST OR ASSIGNS.

DEVELOPMENT AREA MAP

1" = 100'