[KHAN_PSDC_KNOW HOW] January 29, 2010HEAT EXCHANGER DESIGN IN HYSYS ENVIRONMENTDear PSDC member I would like to share my experience of heat exchanger design in hysys. Being a member of PSDC you must have good hysys skill for carry out your future research and the lab assignment given to you. First of all start using hysys with the manual as it will make you familiar with the basic terminology and the operations you can carry out in hysys. Then after quickly following the basic, start doing exTRANSCRIPT
[ ] January 29, 2010
HEAT EXCHANGER DESIGN IN HYSYS ENVIRONMENT
Dear PSDC member I would like to share my experience of heat exchanger design in hysys.
Being a member of PSDC you must have good hysys skill for carry out your future research and
the lab assignment given to you. First of all start using hysys with the manual as it will make you
familiar with the basic terminology and the operations you can carry out in hysys. Then after
quickly following the basic, start doing example provided in the manual and tries to do as much
as you can to gain enough confidence before delving into the details of the assignments.
Now you have basic idea about hysys and you are particularly concerns about the design of
heat exchanger so before designing you usually have some idea about heat exchanger from
thermodynamic point of view like:
How much heat you can transfer from hot stream to cold stream calculated by first law
of thermodynamic (energy can neither be created nor destroyed it just transform).
Also you should know the direction of heat transfer as stated by second law of
thermodynamics heat can flow only from higher temp to lower temp.
Maximum allowable pressure drop from one or both stream (depends on specific
application) like that.
There are so many things that you should know but these are just some stating points now we
will move to the more specific problems which a newcomer usually encounters with:
[ ] January 29, 2010
OVERSPECIFIED
After you specify all the details of inlet and outlet stream your heat exchanger is not
converged means it is still yellow in color and show error “over specified” it means you
have either input extra values and there is no room for hysys to calculate heat duty, UA
and other things so you need to remove some specified values like temp, pressure, &
vapor fraction and leave some job for Hysys engine to perform the task for you, so as
soon as you delete some values hysys perform calculation and according to condition it
will calculate the required value and converged.
[ ] January 29, 2010
UNDERSPECIFIED
This error means your streams on the basis of which hysys will perform calculation is not
fully define so you need to specify the required value like temp, pressure, mole or mass
flow rate & vapor fraction. There are many ways you can do this the most easy and
convenient way is to open the worksheet under the condition menu of Heat exchanger
and you can see all streams at once and specify the required value there and then your
heat exchanger will be fixed.
[ ] January 29, 2010
FRICTION FACTOR LOW & TEMPERATURE CROSSING
This is the most annoying thing which I have faced it happens just because of
thermodynamic violation, the available heat which we have in hot stream we can only
transfer that amount to the cold stream beyond which we cannot transfer. Temperature
crossing happens when the cold side is being heated to a temperature that is above the inlet
temperature of the hot side.
[ ] January 29, 2010
The remedy for this problem is try to increase the flow rate of hot or cold stream to
reach the minimum duty of heat required for the particular operation and if you have
freedom to change the temperature try to adjust the temperature to avoid the
thermodynamic violations.
I hope these tips will fix your problem if you still have problem you can ask senior guys
them will help you to sort out your problem.