han d / dd - harting rectangular connectors | electrical ... · contacts han d ® ... material...

24
02 · 1 Contents Page Han ® 7 D .................................................................................................. 02.2 Han ® 8 D .................................................................................................. 02.4 Han ® 15-128 D......................................................................................... 02.6 Contacts Han D ® ...................................................................................... 02.14 Han DD ® .................................................................................................. 02.16 Contacts Han DD ® ................................................................................... 02.23 Han D/DD Han D ® / DD ®

Upload: phamtruc

Post on 09-Nov-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

02·1

Contents Page

Han® 7 D .................................................................................................. 02.2

Han® 8 D .................................................................................................. 02.4

Han® 15-128 D ......................................................................................... 02.6

Contacts Han D® ...................................................................................... 02.14

Han DD® .................................................................................................. 02.16

Contacts Han DD® ................................................................................... 02.23

Han D/DD

Han D® / DD®

02·2

Features• Innovative Han-Quick Lock® termination with reduced wiring

times• Time saving rapid termination by use of crimping contacts• for requirements up to 250 V / 10 A• Gold and silver contacts available• Suitable for thermo- and 1 mm FO contacts

Technical characteristicsNumber of contacts 7Electrical data acc. to IEC 61984

10 A 250 V 4 kV 3

Rated current 10 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage acc. to UL 600 VInsulation resistance ≥1010 ΩContact resistance ≤3 mΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 HBMating cycles ≥500Material (insert) PolyamideColour (insert) RAL 7032 (pebble grey)Material (seal) NBRMaterial (contacts) Copper alloy

DeratingCurrent carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-inter-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques acc. to IEC 60512-5-2

Ope

ratin

g cu

rrent

(A)

Ambient temperature (°C)

Ope

ratin

g cu

rrent

(A)

Ambient temperature (°C)① Han® 7 D ② Han® 15 D ③ Han® 25 D ④ Han® 40 D ⑤ Han® 64 D

Specifications and approvalsEN 60664-1IEC 61984EN 175301-801UL 1977 ECBT2.E235076

, ,

Han D/DD

Han® 7 D

02·3

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Han-Quick Lock® termination, Contact surface:Silver plated

Only for thermoplastic hoods / housings

0,25 ... 1,5 09 21 007 2632 09 21 007 2732

Contact arrangement (view from termination side)

Han D® , Crimp termination

Please order crimp contacts separately.Only for thermoplastic hoods / housings

0,14 ... 2,5 09 21 007 3031 09 21 007 3131

Contact arrangement (view from termination side)

Han D/DD

Han® 7 D Size 3 A

Number of contacts

7+ 10 A 250 V 4 kV 3

02·4

Features• Innovative Han-Quick Lock® termination with reduced wiring

times• Time saving rapid termination by use of crimping contacts• Gold and silver contacts available• Suitable for metal hoods and housings size Han® 3 A• High density of contacts

Technical characteristicsNumber of contacts 8Electrical data acc. to IEC 61984

10 A 50 V 0,8 kV 3

Rated current 10 ARated voltage 50 VRated impulse voltage 0.8 kVPollution degree 3Rated voltage 50 V AC, 120 V DCRated voltage acc. to UL 50 VRated voltage acc. to CSA 50 VInsulation resistance ≥1010 ΩContact resistance ≤3 mΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 HBMating cycles ≥500Material (insert) PolyamideColour (insert) RAL 7032 (pebble grey)Material (seal) NBRMaterial (contacts) Copper alloy

Specifications and approvalsEN 60664-1IEC 61984EN 175301-801UL 1977 ECBT2.E235076

, ,

Han D/DD

Han® 8 D

02·5

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Han-Quick Lock® termination, Contact surface:Silver plated

for thermoplastics and metal hoods/housings

0,25 ... 1,5 09 36 008 2632 09 36 008 2732

Contact arrangement (view from termination side)

Han D® , Crimp termination

Please order crimp contacts separately.for thermoplastics and metal hoods/housings

0,14 ... 2,5 09 36 008 3001 09 36 008 3101

Contact arrangement (view from termination side)

Han D/DD

Han® 8 D Size 3 A

Number of contacts

810 A 50 V 0,8 kV 3

02·6

Features• High density of contacts• for requirements up to 250 V / 10 A• Time saving rapid termination by use of crimping contacts• Gold and silver contacts available• Suitable for thermo- and 1 mm FO contacts

Technical characteristicsNumber of contacts 15, 25, 40, 50, 64, 80, 128Electrical data acc. to IEC 61984

10 A 250 V 4 kV 3

Rated current 10 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage acc. to UL 600 VRated voltage acc. to CSA 600 VInsulation resistance ≥1010 ΩContact resistance ≤3 mΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 V-0, HBMating cycles ≥500Dimensions wire wrap post 1 x 1 mmTermination length 22 mmMaterial (insert) PolycarbonateColour (insert) RAL 7032 (pebble grey)Material (contacts) Copper alloy

DeratingCurrent carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-inter-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques acc. to IEC 60512-5-2

Ope

ratin

g cu

rrent

(A)

Ambient temperature (°C)

Ope

ratin

g cu

rrent

(A)

Ambient temperature (°C)① Han® 7 D ② Han® 15 D ③ Han® 25 D ④ Han® 40 D ⑤ Han® 64 D

Specifications and approvalsEN 60664-1IEC 61984EN 175301-801UL 1977 ECBT2.E235076

, ,

DetailsATTENTION! Guide pins and bushes are prescribed (see chap-ter 80).

Han D/DD

Han® 15-128 D

02·7

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 21 015 3001 09 21 015 3101

1) distance for contact max. 24 mm

Han D® , Wrap termination

09 21 015 2601 09 21 015 2701

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 15 D Size 10 A

Number of contacts

15+ 10 A 250 V 4 kV 3

02·8

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 21 025 3001 09 21 025 3101

1) distance for contact max. 24 mm

Han D® , Wrap termination

09 21 025 2601 09 21 025 2701

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 25 D Size 16 A

Number of contacts

25+ 10 A 250 V 4 kV 3

02·9

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 21 040 3001 09 21 040 3101

1) distance for contact max. 21 mm

Han D® , Wrap termination

09 21 040 2601 09 21 040 2701

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 40 D Size 16 B

Number of contacts

40+ 10 A 250 V 4 kV 3

02·

10

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp termination

Please order crimp contacts separately.You need two inserts for a com-plete assembly!

0,14 ... 2,5 09 21 025 3001 09 21 025 3101

1) distance for contact max. 24 mm

Han D® , Wrap termination

You need two inserts for a com-plete assembly!

09 21 025 2601 09 21 025 2701

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 50 D Size 32 A

Number of contacts

50+ 10 A 250 V 4 kV 3

02·

11

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 21 064 3001 09 21 064 3101

1) distance for contact max. 21 mm

Han D® , Wrap termination

09 21 064 2601 09 21 064 2701

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 64 D Size 24 B

Number of contacts

64+ 10 A 250 V 4 kV 3

02·

12

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp termination

Please order crimp contacts separately.You need two inserts for a com-plete assembly!

0,14 ... 2,5 09 21 040 3001 09 21 040 3101

1) distance for contact max. 21 mm

Han D® , Wrap termination

You need two inserts for a com-plete assembly!

09 21 040 2601 09 21 040 2701

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 80 D Size 32 B

Number of contacts

80+ 10 A 250 V 4 kV 3

02·

13

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp termination

Please order crimp contacts separately.You need two inserts for a com-plete assembly!

0,14 ... 2,5 09 21 064 3001 09 21 064 3101

1) distance for contact max. 21 mm

Han D® , Wrap termination

You need two inserts for a com-plete assembly!

09 21 064 2601 09 21 064 2701

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 128 D Size 48 B

Number of contacts

128+ 10 A 250 V 4 kV 3

02·

14

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp contact, Contact surface:Silver plated

0,14 ... 0,370,50,7511,52,5

09 15 000 610409 15 000 610309 15 000 610509 15 000 610209 15 000 610109 15 000 6106

09 15 000 620409 15 000 620309 15 000 620509 15 000 620209 15 000 620109 15 000 6206

Han D® , Crimp contact, Contact surface:Gold plated

0,14 ... 0,370,50,7511,52,5

09 15 000 612409 15 000 612309 15 000 612509 15 000 612209 15 000 612109 15 000 6126

09 15 000 622409 15 000 622309 15 000 622509 15 000 622209 15 000 622109 15 000 6226

Han D/DD

Contacts Han D®

Technical characteristicsContact resistance ≤3 mΩMaterial (contacts) Copper alloyMaterial (accessories) Thermoplastic

Specifications and approvalsEN 60664-1IEC 61984

DetailsCrimping tools see chapter 90

Remarks on the crimp techniqueThe wire gauges mentioned in the catalogue refer to geometric wire gauges of cables.

Coding pinUse of the coding pin prevents incorrect mating to other connec-tors of the same type. The male pin should be omitted from the opposing cavity in the male insert.

02·

15

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

FO contact, for 1 mm plastic fibre

20 10 001 321220 10 001 3213

20 10 001 3222

20 10 001 3212 + 20 10 001 3222for Han® 7 D, Han® 8 D, Han® 40 D, Han® 64 D, Han® 80 D, Han® 128 D

20 10 001 3213 + 20 10 001 3222for Han® 15 D, Han® 25 D, Han® 50 D

Han D® Han DD® , Coding pin

Only for crimp terminationWith loss of one contact

09 33 000 9915

Han D/DD

Contacts Han D®

02·

16

Features• High density of contacts• for requirements up to 250 V / 10 A• Time saving rapid termination by use of crimping contacts• Gold and silver contacts available• Suitable for thermo- and 1 mm FO contacts

Technical characteristicsNumber of contacts 24, 42, 72, 108, 144, 216Electrical data acc. to IEC 61984

10 A 250 V 4 kV 3

Rated current 10 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage acc. to UL 600 VRated voltage acc. to CSA 600 VInsulation resistance ≥1010 ΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 V-0Mating cycles ≥500Material (insert) PolycarbonateColour (insert) RAL 7032 (pebble grey)

DeratingCurrent carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-inter-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques acc. to IEC 60512-5-2

Ope

ratin

g cu

rrent

(A)

Ambient temperature (°C)① Han® 24 DD ② Han® 42 DD ③ Han® 72 DD ④ Han® 108 DD

Derating

Ope

ratin

g cu

rrent

(A)

Ambient temperature (°C)① Han® 24 DD ② Han® 42 DD ③ Han® 72 DD ④ Han® 108 DD

Specifications and approvalsEN 60664-1IEC 61984

, ,

DetailsGuide pins and bushes are recommended (see chapter 80).

Han D/DD

Han DD®

02·

17

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han DD® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 16 024 3001 09 16 024 3101

1) distance for contact max. 21 mm

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 24 DD Size 6 B

Number of contacts

24+ 10 A 250 V 4 kV 3

02·

18

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han DD® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 16 042 3001 09 16 042 3101

1) distance for contact max. 21 mm

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 42 DD Size 10 B

Number of contacts

42+ 10 A 250 V 4 kV 3

02·

19

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han DD® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 16 072 3001 09 16 072 3101

1) distance for contact max. 21 mm

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 72 DD Size 16 B

Number of contacts

72+ 10 A 250 V 4 kV 3

02·

20

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han DD® , Crimp termination

Please order crimp contacts separately.

0,14 ... 2,5 09 16 108 3001 09 16 108 3101

1) distance for contact max. 21 mm

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 108 DD Size 24 B

Number of contacts

108+ 10 A 250 V 4 kV 3

02·

21

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han DD® , Crimp termination, 1 ... 72

Please order crimp contacts separately.You need two inserts for a com-plete assembly!

0,14 ... 2,5 09 16 072 3001 09 16 072 3101

1) distance for contact max. 21 mm

Han DD® , Continuing marking, Crimp termination, 73 ... 144

Please order crimp contacts separately.You need two inserts for a com-plete assembly!

0,14 ... 2,5 09 16 072 3011 09 16 072 3111

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 144 DD Size 32 B

Number of contacts

144+ 10 A 250 V 4 kV 3

02·

22

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han DD® , Crimp termination, 1 ... 108

Please order crimp contacts separately.You need two inserts for a com-plete assembly!

0,14 ... 2,5 09 16 108 3001 09 16 108 3101

1) distance for contact max. 21 mm

Han DD® , Continuing marking, Crimp termination, 109 ... 216

Please order crimp contacts separately.You need two inserts for a com-plete assembly!

0,14 ... 2,5 09 16 108 3011 09 16 108 3111

Contact arrangement (view from termination side)

Panel cut outfor use without hood

Han D/DD

Han® 216 DD Size 48 B

Number of contacts

216+ 10 A 250 V 4 kV 3

02·

23

Identification

Conductor cross-section (mm²)

Part number Drawing (dimensions in mm)Male Female

Han D® , Crimp contact, Contact surface:Silver plated

0,14 ... 0,370,50,7511,52,5

09 15 000 610409 15 000 610309 15 000 610509 15 000 610209 15 000 610109 15 000 6106

09 15 000 620409 15 000 620309 15 000 620509 15 000 620209 15 000 620109 15 000 6206

Han D® , Crimp contact, Contact surface:Gold plated

0,14 ... 0,370,50,7511,52,5

09 15 000 612409 15 000 612309 15 000 612509 15 000 612209 15 000 612109 15 000 6126

09 15 000 622409 15 000 622309 15 000 622509 15 000 622209 15 000 622109 15 000 6226

FO contact, for 1 mm plastic fibre

20 10 001 3211 20 10 001 3221

20 10 001 3211 + 20 10 001 3221

Han D® Han DD® , Coding pin

Only for crimp terminationWith loss of one contact

09 33 000 9915

Han D/DD

Contacts Han DD®

Technical characteristicsContact resistance ≤3 mΩMaterial (contacts) Copper alloyMaterial (accessories) Thermoplastic

Specifications and approvalsEN 60664-1IEC 61984

DetailsCrimping tools see chapter 90

Remarks on the crimp techniqueThe wire gauges mentioned in the catalogue refer to geometric wire gauges of cables.

Coding pinUse of the coding pin prevents incorrect mating to other connec-tors of the same type. The male pin should be omitted from the opposing cavity in the male insert.

02·

24

Han D/DD

Modified contact arrangement

Modified contact arrangement The connector series Han DD® and Han D® equipped with all contacts may be used for voltages up to 250 V, pollution degree 3. A modified contact loading arrangement permits use up to 500 V also in the same pollution degree.

According to DIN EN 61 984 connectors should not be coupled or decoupled under electrical load.

Series Han DD®

10 A 400 V 6 kV 3Rated current 10 A Rated voltage 400 V Rated impulse voltage 6 kV Pollution degree 3

Contact arrangement view from termination side

10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3

● Working contact ○ Without contact M - Male insert F - Female insert

Series Han D®

10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3

Contact arrangement view from termination side

● Working contact ○ Without contact M - Male insert F - Female insert

Modified contact arrangement The connector series Han DD® and Han D® equipped with all contacts may be used for voltages up to 250 V, pollution degree 3. A modified contact loading arrangement permits use up to 500 V also in the same pollution degree.

According to DIN EN 61 984 connectors should not be coupled or decoupled under electrical load.

Series Han DD®

10 A 400 V 6 kV 3Rated current 10 A Rated voltage 400 V Rated impulse voltage 6 kV Pollution degree 3

Contact arrangement view from termination side

10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3

● Working contact ○ Without contact M - Male insert F - Female insert

Series Han D®

10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3

Contact arrangement view from termination side

● Working contact ○ Without contact M - Male insert F - Female insert