THE DURABLE AND CLEAN SOLUTION

ArmAflex® eDl – Foil-faced and self adhesive sheeting for insulation of equipment cabinets, ducting, storage tanks and pipe work.

zero

GWP

zero

ODP

low

VOC

• excellent fi re and weathering resistance

• washable surface to support hygiene maintenance

• non-wicking to reduce water presence in system and insulation

• high fl exibility for ease of fi tting

• self adhesive for fast and cost-effective application

• fi bre-free to prevent potential air-quality problems

• closed-cell insulation to provide a continuous barrier to water vapour

• low thermal conductivity for effective energy saving and CO

2 reduction

• genuine FR/Armafl ex performance

Product Description

Benefi ts

Armafl ex EDL is a foil-faced elastomeric thermal insulation, supplied with a high performance self-adhesive backing. It is constructed from Armacell’s proven FR/Armafl ex insulation material. Armafl ex EDL is suitable for insulation of equipment cabinets, storage tanks, and air-conditioning ducts. Its superior-grip Pressure Sensitive Adhesive system makes it applicable in non-pinned fi eld applications. It is also highly suited for raised-fl oor or under-fl oor air-conditioning systems.

Air Conditioning and Ventilation refrigeration

Technical Properties

Outdoor applications - Armafl ex EDL does not require painting

condensation control

fl exible and fi bre free

durable and smoothsurface

self-adhesive

Short description Values remarks

Temperature range

For all applications outside this range, pleasecontact our technical department.

(Temperature limits)

Max. surface temperature +85°C

Min. surface temperature -40°C

Water Vapour Permeability u>4,500 Tested according to ASTM E96

Temperature conductivity (λ) K-value

At 0°CAt 25°C

0.036 W/(m.K)0.038 W/(m.K)

Tested according to ASTM C518

fire performance

Ignitability Index..................Spread of Flame Index.......Heat Evolved Index.............Smoke Developed Index.....Low Potential Smoke and Toxicity Hazard R = 0.43

Tested according to AS/NZS 1530.3 1999

Durability and resistance

Weathering and UV resistance Excellent Tested according to SAE J1885-1992

Size rangeAvailable in both sheets and continuous rolls

Sheets: 1.0m x 1.5mRoll width: 1.0m6mm, 9mm, 13mm, 19mm and 25mm thickness

0000-1

Tested according to BS 6853. 1999 Clause B.4.2

Condensation Control

Armaflex insulation provides excellent control of condensation. The thickness required will depend on the ambient air temperature, the relative humidity in the environment, and the temperature of the surface to be insulated. The level of airflow around any insulation will also affect its control of condensation.

The surface characteristics of insulation material will affect its performance. Insulation that is covered with a shiny metal surface needs to be used in greater thickness than insulation with a black or non-reflective surface. Insulation with a shiny surface will reflect radiant heat, causing the surface to become cooler. To prevent the dew point occurring on the material’s surface (this is the point where condensation occurs) any metal-covered insulation must be used in greater thickness than insulation with a black non-reflective surface.

The foil-facing on Armaflex EDL provides many benefits; the surface is highly resistant to fire, it is easily cleaned to provide hygienic and aesthetic advantages, and the foil provides an additional vapour barrier. In selecting the material’s thickness the effect of foil should be recognised, and the material applied in greater thickness than standard Armaflex.

If you have any questions about your particular application, and the thickness of material required, please contact Armacell for Technical Service and recommendations.

Self-adhesive foil-facedThickness Product code length Per Carton

mm Inches metres

13 ½ 9U1300CS 8

19 ¾ 9U1900CS 6

25 1 9U2500CS 4

Self-adhesive roll (1m width)

For applications that do not require a foil face, FR/Armaflex is availble with a self-adhesive backing, as listed below:

Self-adhesiveThickness Product code Quantity Per Carton

mm Inches Sheets Square metres

6 ¼ 9U060001 30 45

9 9U090001 20 30

13 ½ 9U130001 15 22.5

19 ¾ 9U190001 10 15

25 1 9U250001 8 12

Self-adhesive sheet (1m x 1.5m)

38

Self-adhesive foil-facedThickness Product code length Per Carton

mm Inches metres

6 ¼ 9E0600CS 15

9 9E0900CS 10

13 ½ 9E1300CS 8

19 ¾ 9E1900CS 6

25 1 9E2500CS 4

Self-adhesive foil-faced roll (1m width)

38

Self-adhesive foil-faced sheet (1m x 1.5m)

Self-adhesive foil-facedThickness Product code Quantity Per Carton

mm Inches Sheets Square metres

13 ½ 9E130001 15 22.5

19 ¾ 9E190001 10 15

25 1 9E250001 8 12

May 2007

Armacell Australia PTY LTD13-17 Nathan Road, Dandenong, Victoria, 3175T +613 8710 5999 F+613 8710 5900www.armaflex.com.au [email protected]

Installation Tips

Note: For further information consult the Armaflex Installation Manual

1

The temperature of the air and of the insulation should be between 10°C and 35°C at the time of installation.

Surface to be covered should be cleaned of all loose material, dust, grease and oil. Use a commercial degreaser and solvent wipe.

Cut with sharp knife. Peel back enough release liner to start.

Square off sheet along an edge or corner. Press the sheet to the surface taking care not to trap any air.

Reach behind the Armaflex sheet and peel liner back while pressing the sheet to the surface. Remove the entire liner piece.

Press firmly. Butt joints require the use of compression to prevent the possible opening of seams.

2 3 4

5 6 7

All joins in Armaflex EDL should be sealed with a high-grade aluminium foil. When using non-foil faced sheeting, ensure all exposed edges and joins are sealed with Armaflex 520 adhesive.

General Instructions

• Armaflex EDL is highly flexible and can easily be wrapped around a duct, cabinet, vessel or large-diameter pipe work.

• For very thick material (25mm), and for internal lining of small areas, it can easily be cut and fitted as small sheets.

• The backing material is a pressure-sensitive adhesive, and requires the application of pressure across all areas to complete the bonding. Care should be taken to align the material, as it cannot be removed after the adhesive bonds and cures.

Armaflex Around Ducting

1

For cladding of ducts, insulate the base first, then the sides, and finish with the top. This ensures a cleaner appearance and eliminates seems at the top, where moisture can drop down.

Roll a cylindrical object across the material repeatedly to apply solid and even pressure across all the adhesive system.

The top should cover the side edges, leaving no exposed seems on top. Use a brush to force Armaflex adhesive between all joins to complete the vapor seal.

Standing ribs can be insulated with strips of sheet Armaflex that are built-up around the area. Alternatively ribs can be insulated with Armaflex pipe-insulation that is cut in half and mitred at the edges.