Very Important Points for Agilent plate form testing

For new or Used Laptops ALWAYS ALWAYS • Disable or block firewall, security features on the Computers

Never ever install any new software on the Laptop except Agilent. After starting the car warm it up for a while then turn on the inverter. Before starting the test check all the cables, specially scanner cable for GPS and Scanner

Antenna cables or tight and safe. If you are going to different market, before leaving the base station, always check Dongles

key’s License expiration. Take with you any extra laptop, phone, air card, and GPS. Keep the Scanner Bar window open, keeping on comparing Scanner RSSI with Phones

RSSI.( Scanner RSSI is > than phones:e.g. -77 > -88) For FTP trouble Shoot, always start from AT Command, Check AT command in the modem

advance setting it should be defined For Chicago: AT+CGDCONT=1,”IP”,”isp.cingular” On Down load or Kit1, check for FTP down load, retrieving massage in sequence

window. If it is not there, check, FTP properties again. On Upload or Kit2, check for FTP upload, storing massage in sequence window If it is not there, check, FTP properties again. Live Mode: Shift +F4 Start recording: Mode F4 Stop recording: Shift +F9

Page 3: Guide Line Agilent Plate Form

3 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Agilent Important Commands: AIRCARD and Phones For USB Configuration:

*#197328640# option 9__option 6__option 2 LOCK the phones TO UMTS/GSM/AUTO(To change the phone mode)

*#63895# or *#3685247*# To verify the PHONE mode (you can see on the phone screen)

*#0011# In order to prevent data on CS phones

1)Press *#3685247#*

2)Select ''Network & call settings'' 3) Select "Service Domain"

4) Select "CS"

5) Press ''Save``

This way you can verify Central frequency from the phone pad, by locking the phone to UMTS850 or UMTS1900 (In Chicago for UMTS850 it is 4384 and UMTS1900 is 612) (In Montreal, Canada for UMTS850 it is 1087(UMTS V(850 Mhz) and UMTS1900 is 587(UMTS II 1.9Ghz)) AT Command Air CARD Lock up

Connect to AIR CARD AT!ENTERCND=”A710” (TO CONNECT TO AIR CARD) To Lock the Air card to UMTS UMTS AUTO 850/1900 AT!GBAND=03FFFFFFF( or Also in 3G Watcher you can check 3G only) UMTS 850 AT!GBAND=04000000 UMTS 1900 AT!GBAND=0800000 To Lock the Air card to GSM GSM AUTO 850/1900 AT!GBAND=03FFFFFFF( or Also in 3G Watcher you can check 2G only) GSM 850 AT!GBAND=0280000 GSM 1900 AT!GBAND=0200000 To verify the Air card locked Mode for GSM/UMTS AT!GBAND?

Page 4: Guide Line Agilent Plate Form

4 Pervez Durrani RF Engineer GTLAmericas 910-5391026

UE Settings to fix iRate sessions: Samsung A737 by following these simple steps.

Press/Select Menu > Settings(Option 9) > Connectivity (Option 7) > IMS Settings (Option 4) > Profiles (Option 2) and then select IMS and Save. The profile itself does not need to be edited.

Winsock Error:

TCP/IP is a set of communications protocol used for the internet and other similar networks. TCP/IP can sometimes get damaged or corrupted, in case you can't connect to the internet and have tried various other methods with no success, most probably corrupted TCP/IP is the reason behind it. As TCP/IP is a core windows component it can't be removed , however , it can be reset/repair to its original state by couple of methods mentioned below. Method 1:

1) Go to Start menu and open command prompt.

2) At the command prompt , copy and paste(or type) the following command and then press ENTER:

netsh int ip reset c:\resetlog.txt

When we run the reset command, it rewrites two registry keys that are used by TCP/IP. This has the same result as removing and reinstalling the protocol.

3) Reboot the computer and you should be all set.

Method 2:

An easier way is to just click either of these links, start winsock.dll download and then reboot your computer :

http://www.online-tech-tips.com/computer-tips/winsock-fix/

OR

http://support.microsoft.com/?kbid=299357

Page 5: Guide Line Agilent Plate Form

5 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Procedure to delete the cookies and clear the registry:

For Internet Explorer do the following steps:

1) Open internet explorer.

2) On the menu bar , click tools and select Internet Options.

3) Under Browsing history click Delete.

4) Select delete all.

To Clear the Registry, Download Ccleaner from www.Download.com

http://download.cnet.com/1770-20_4-0.html?query=ccleaner&tag=srch&searchtype=downloads&filterName=platform%3DWindows,Webware&filter=platform%3DWindows,Webware

Precautions for laptops:

• ALWAYS disable firewall, auto updates, screen-savers & security features on the laptops.

• Change the battery settings to “Never” for the entire power plan. • Disable shock sensor for hard disk drive by going to Control Panel. (Mostly found IBM

laptops). Precautions for Agilent kit & phones:

• Before starting the test check all the cables, especially scanner cable for GPS and Scanner antenna cables, which should tight and safe.

• Make sure to raise the laptops to ensure sufficient air flow for laptops to cool down (It helps increase the life of the laptop as well).

• Make sure to select USB configuration on Qualcomm Chipset phones. Dial: *#197328640# -> Option 9 -> Option 6 -> Select Qualcomm USB

General Precautions:

Page 6: Guide Line Agilent Plate Form

6 Pervez Durrani RF Engineer GTLAmericas 910-5391026

• Make sure all the hardware is getting enough power from the car battery through inverter.

• Make sure to tape the connected power cables to reduce short circuit risks. • Make sure to carry extra cables. • Make sure to save Scanner\Phone drivers on the laptops.

Agilent kit set-up:

• Install Agilent on the laptop. • Connect phones to the laptop. • Install “Scanner\Phone drivers” when prompted. • Insert Aircard, which will auto install its drivers. • Manually setup a dial-up connection. • Make a work space of Agilent (upload or download) with properties as per market

requirement. • Be sure to clone a template of the project in the same laptop for future convenience.

HOW TO FORCE COMPASS 888 TO SPECIFIC CHANNEL (Montreal Canada TELUS IN THIS CASE)

1)WITH THE HELP OF HYPERTERMINAL SELECT AUTO BAND SELECTION USING

AT!ENTERCND=”A710”

AT!GBAND=3FFFFFFF

2)OPEN SIERRA WIRELESS WATCHER SET NETWORK SELECTION IN AUTOMATIC MODE

Page 7: Guide Line Agilent Plate Form

7 Pervez Durrani RF Engineer GTLAmericas 910-5391026

3)AGAIN OPEN HYPERTERMINAL USE THESE COMMANDS

AT!ENTERCND=”A710”

AT!CUSTOM=”HSDPATEST”,1

AT!RESET

PLEASE GIVE SUFFICIENT TIME FOR COMPASS TO RESET COUPLE OF MINS IS OK.

4) OPEN SIERRA WIRELESS WATCHER AND GOTO NETWORK NOW YOU CAN FIND NEW “HSDPATEST SETUP” SETTING ADDED IN NETWORK TAB

Page 8: Guide Line Agilent Plate Form

8 Pervez Durrani RF Engineer GTLAmericas 910-5391026

5) In HSDPA Test Setup . We need to do this in proper sequence

a) Enabled……… Yes

PLEASE DO NOT RESCAN BEFORE PUTTING RIGHT CHANNEL AS IF NOW

b) Channel Number is Centre frequency of 850 Band. As 850 Band usually camps on Rogers and we need to force Telus channel number in this case.

USE YOUR 850 BAND CENTRE FREQUENCY IN CHANNEL NUMBER.

c) Apply

d) Rescan Now…… Yes

Please give sufficient time for Compass to catch the right channel.

e) Press OK

Cross your fingers for Blue light on compass

Please check that following criterias are met when you do a Scope 2 stationary test.

Page 9: Guide Line Agilent Plate Form

9 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Stationary TEST: For stationary test keep the following points in mind

1) Right scrambling code is isolated ( single SC serving)

2) Rx Power below -75

3) Download throughput more than 5500 kbps

4) Upload throughput more than 1200 kbps (to check upload throughput open device views - 0850PS- HSUPA throughput chart.

5) Ping - Time less than 70ms (milliseconds)

This is most important. Unfortunately you can not see ping time in Agilent for that you need to do this

a) connect to internet through dialup modem (HSPA_PS or any other you created)

b) open Start ------ Run-------- cmd------- this will open command/Dos prompt

c) type this to check ping time

ping -t 10.179.253.14

if ping is less than 70ms constantly then you can start test otherwise.....

d) open website www.google.com and check whether ping time become ok if yes then you should keep that Google website open and when Agilent start connecting for ping just refresh the Google page. make sure you don’t pass 3/4 pings before you refresh.

6) Attach / Detach test are with 15 sec wait time between each other so in both test put wait time 15 seconds.

7) Don’t forget to do manual video calls.

Page 10: Guide Line Agilent Plate Form

10 Pervez Durrani RF Engineer GTLAmericas 910-5391026

C888 Firmware upgrade and toolsV2.doc:

1) Download FW upgrade (a) and Watcher upgrade (b) as follow: a) https://extranet.sierrawireless.com/engineering/approva

ls/filedrop

b) user: swirguest

password: filedrop

File: BZ16435_K2_0_6_5BT_K2_0_6_7AP_EnableDirectIp.zip

b) Watcher_Generic_2062.msi which is available on Sierra web site as follow:

http://www.sierrawireless.com/resources/software/watcher/Build2062/Watcher_Generic_2062.msi

2) Disconnect physically all external modems and C888 from the PC

3) Remove previous modem created with C888 on PC (control panel -> phone and modems options):

Page 11: Guide Line Agilent Plate Form

11 Pervez Durrani RF Engineer GTLAmericas 910-5391026

4) Uninstall all COM ports created for the Sierra C888 on PC called Sierra Wireless Application Interface and Sierra Wireless Diagnostic Interface (control panel -> System -> Hardware TAB -> Device Manager -> Ports (COM&LPT)):

5) Remove previous watcher installed on PC (control panel -> add or remove programs):

Page 12: Guide Line Agilent Plate Form

12 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Page 13: Guide Line Agilent Plate Form

13 Pervez Durrani RF Engineer GTLAmericas 910-5391026

6) Delete in program files the directory of the 3G watcher and the True Install

7) Install new Watcher with following file downloaded previously (C888 should be physically disconnected from PC):

Watcher_Generic_2062.msi

8) Disconnect all modems from PC and have C888 physically connected alone with Watcher OFF (Watcher will start automatically during FW upgrade). Double click FW upgrade file and C888 will be detected and FW download and upgrade will start (upgrade file: BZ16435_K2_0_6_5BT_K2_0_6_7AP_EnableDirectIp.exe). This will take 10 to 20 minutes, PC activity should be minimized and C888 should not be ejected during the upgrade.

a) Download phase 1 (automatic):

Page 14: Guide Line Agilent Plate Form

14 Pervez Durrani RF Engineer GTLAmericas 910-5391026

b) Upgrade phase 2 (automatic):

c) Upgrade completed successfully (press OK):

9) With C888 still physically connected on PC, run the following exe file to enable DM port and dialup modem. Those ports are mandatory for drive test data collection with Agilent:

Page 15: Guide Line Agilent Plate Form

15 Pervez Durrani RF Engineer GTLAmericas 910-5391026

10) The above FW allows HSDPA cat8 (7.2Mbps max) with no further action

11) The above FW allows HSUPA cat5 (2.1Mbps max) with no further action

12) Upgrade to HSUPA cat6 (5.76Mbps) is possible with following AT command (using AT com port of the device) but this FW is running on a Beta release for HSUPA cat6:

AT!HSUCAT=6

AT!HSUCAT=5 (limit capability back to HSUPA cat5)

13) Monitoring tool is available to force bands and verify key indicators from the C888 (exe file below).

Page 16: Guide Line Agilent Plate Form

16 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Connection for AIR CARD: Go to properties and check Modem-Sierra Wireless Air Card 881 HSDPA Modem

Page 17: Guide Line Agilent Plate Form

17 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Hyper Terminal: To access Hyper Terminal: Click on the Hyper Terminal Icon:

Go to file and then Properties and click it to open

Type any Name, you like, in this case Hyper Terminal

Page 18: Guide Line Agilent Plate Form

18 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Pick the proper port from drop down window.

From device Manager you have to conform the AT port

After this you can access the Hyper Terminal window to write in

Page 19: Guide Line Agilent Plate Form

19 Pervez Durrani RF Engineer GTLAmericas 910-5391026

How to create a Dialup Connection?

Go to Start- All Programs---Accessories---Communication----Network

Connection It will bring you new window: New Connection Wizard click next

Check Set my connection manually and next

Page 20: Guide Line Agilent Plate Form

20 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Check Connect to the Internet

Check Connect using a dial-up modem and

Important: Conform the port from Device Manager under Modem drop down

Page 21: Guide Line Agilent Plate Form

21 Pervez Durrani RF Engineer GTLAmericas 910-5391026

You can Name whatever you want it: Here we named it as HSDPA

In this case phone number is *99#(however in each market you get this number)

Page 22: Guide Line Agilent Plate Form

22 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Put AT command in device manager under USB Modem, find the port and then go to advance and add the AT command there(Very Important)

Page 23: Guide Line Agilent Plate Form

23 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Short cut on desktop

Click on the ICON

Click Dial, and verify internet is working?

Page 24: Guide Line Agilent Plate Form

24 Pervez Durrani RF Engineer GTLAmericas 910-5391026

RSCP = Received Signal Code Power = UE Aggregate Ec (dbm) and this roughly correlates to SC Analyzer Aggregate Ec (dbm).

Step 1: For UE

RSCP by opening a data items panel for the UE, expanding the data items, expanding the data item called UMTS Pilot Channel and selecting Active RSCP (dbm). Open a common view, a bar chart, and then drag and drop the Active RSCP data item into the bar chart. This will look just like the Top N SC Ec/Io view, except that you will see RSCP (dbm) versus common pilot channel CPICH (Ec/Io) which is shown in the Top N Sc Ec/Io view.

Step 2 : Scanner

Aggregate Ec (dbm) in the Scrambling Code Analyzer, open a common receiver bar chart view. Expand the data items under the W-CDMA Scrambling Code Analyzer, expand W-CDMA Top N Scrambling Codes, select SC Agg Ec and drag and drop it into your receiver bar chart view.

Agilent help

Refer to Help in the software if you need assistance configuring the views. Or call 1-800-829-4444 for assistance.

Page 25: Guide Line Agilent Plate Form

25 Pervez Durrani RF Engineer GTLAmericas 910-5391026

How to create a workspace? Create a New Project – “Project Manager”

Example: From Chicago Market

Phone used: QUALCOMMTM7200UMTS Agilent Scanner used: W1314A-113

Workspace examples for different set up: First unzip this and then open the project as a file in Agilent

Workspace_1.zip

Page 26: Guide Line Agilent Plate Form

26 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Chicago Workspace Kit#1: GNG1-CSShortMO: Port assignment

GNG1-UMHSPSLong: Port assignment

GNG1-CSShort MT: Port assignment

GNG1-UMTSScanner: Port assignment

Page 27: Guide Line Agilent Plate Form

27 Pervez Durrani RF Engineer GTLAmericas 910-5391026

W-CDMAUMTS Scrambling Code Analyzer 850:

Important: Downlink. Every market has different center frequency Please ask for it?

IN CHICAGO: For UMTS 850 Channelization: UMTS V (850MHz general) Center Frequency(Downlink)=4384 Preselect or : 864.00MHz-899.00Mhz

IN CHICAGO: For UMTS 1900 Channelization: UMTS II(1.9GHz) Center Frequency(Downlink)=612 Preselect or : 1.925GHz-1.995GHz

Page 28: Guide Line Agilent Plate Form

28 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Sequence: Root:

SERVICE_MODEL:

PARALLEL_SEQUENCE:

Page 29: Guide Line Agilent Plate Form

29 Pervez Durrani RF Engineer GTLAmericas 910-5391026

GNG1-CSShortMO: Properties

GNG1-CSShortMO CALL_CONTROL: Properties

Page 30: Guide Line Agilent Plate Form

30 Pervez Durrani RF Engineer GTLAmericas 910-5391026

GNG1-CSShort MT: Properties

GNG1-CSShort MT: AT_COMMAND=Properties

Page 31: Guide Line Agilent Plate Form

31 Pervez Durrani RF Engineer GTLAmericas 910-5391026

GNG1-CSShort MT: CALL_CONTROL_TEST=Properties

GNG1-UMHSPLong: Properties

Page 32: Guide Line Agilent Plate Form

32 Pervez Durrani RF Engineer GTLAmericas 910-5391026

GNG1-UMHSPLong: DIALUP_TEST: Properties

GNG1-UMHSPLong: FTP_TEST: Properties User Name: chicago Password: chicago2009

Page 33: Guide Line Agilent Plate Form

33 Pervez Durrani RF Engineer GTLAmericas 910-5391026

GNG1-UMHSPLong: DISCONNECT_TEST: Properties

Check Errors?

Network error: At IP address here in Chicago for Download and upload is 209.183.33.5 Use PING command for verification of the server OR on the down load and up load laptops only check FTP and run the sequence.

Ping 209.183.33.5 User Name: ericsson Password: ericsson3g Windsock error 100609 is network error, ip address is not reach able

New IP Address: IP address: 64.124.55.102 User Name: chicago Password: chicago2009 For Down load you have to create 5000k Band width folder at the above location, so that you can download the data. For Upload you have to create 3000k Band width folder at the above location, so that you can upload the data.

Page 34: Guide Line Agilent Plate Form

34 Pervez Durrani RF Engineer GTLAmericas 910-5391026

KIT2: UPLOAD WORK SPACE: GNG1-CSLongMO: PORT assignment

GNG1-EULHSUPA: PORT Assignment:

Sequencer: Properties

Sequencer: Properties SERVICE_MODEL

Sequencer: Properties: PARALLEL_SEQUENCE

Page 35: Guide Line Agilent Plate Form

35 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Sequencer: Properties:GNG1-CSLongMO

Sequencer: Properties: CALL_CONTROL_TEST

Page 36: Guide Line Agilent Plate Form

36 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Sequencer: Properties: GNG1-EULHSUPA

Sequencer: Properties: DIALUP_TEST

Sequencer: Properties: FTP_TEST

Page 37: Guide Line Agilent Plate Form

37 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Sequencer: Properties: DISCONNECT_TEST

Page 38: Guide Line Agilent Plate Form

38 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Agilent Software

Scope two

Stationary Test

Important steps1. SC should be isolated 2. CS 1 and CS 2 Rx should be less than -703. PS or Air card Rx power should also be less than -704. PS ( download ) throughput should be more be 55005. PS ( upload ) should be more 1500 6. Entire test perform only on laptop B except 1900

video calls has to be done on laptop A7. Video calls should be done manually on both the

laptops 8. More importantly each test should pass and if for

some reason any one of test fails, we have to re do the entire test again.

Page 39: Guide Line Agilent Plate Form

39 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Required Hardware's

Two cell phones locked under the band of UMTS 850 CS connected to laptop B

GPS connected to laptop B Air card or PS1 connected to laptop B Two cell phones locked under the band of

UMTS 1900 CS connected to laptop A

Rx Power, SC & Throughput

Rx Power < -70

Throughput > 5500

SC

Page 40: Guide Line Agilent Plate Form

40 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Upload chart

Upload > 1500

Ping test

Ping test should be less than 70ms or 0.070

Page 41: Guide Line Agilent Plate Form

41 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Properties of 850PS1

Properties of HSPA DL 100 MB

Page 42: Guide Line Agilent Plate Form

42 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Properties of HSPA DL & UL disconnect test

Properties of ping test

Page 43: Guide Line Agilent Plate Form

43 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Properties of ping disconnect test

Properties of 850 PS1 for attach & detach

Page 44: Guide Line Agilent Plate Form

44 Pervez Durrani RF Engineer GTLAmericas 910-5391026

Properties of 850 PS 1 ATTACH & DETACH

Video calls • 30 video missed calls from CS1 to CS2 and duration of each missed calls should not be more 10 seconds. • 30 video missed calls should be perform on both the laptops A & B (1900 and 850 )