Page 1: GUI for DRV fix in ICC2

GUI for DRV FIXICC2

- Ch Prashanth

Page 2: GUI for DRV fix in ICC2

Step 1:

source this is ICC2 for GUI source /home/pchokkar/DRV_FIX_GUI.tk

This will add new pull down menu in ICC2

INTRO:

This GUI is to ease the fixing of secondary violations. Input file for this GUI will be either nets’ file or report file. So, you need to grep and sort all the violated nets into a file(one in each line) or select a report file. Either */data_trans.rpt.gz or */clock_trans.rpt.gz report file can be given as report file. Output file will be an ECO file with the custom procs, which you can source in the ICC. Ecos will not be applied in the interactive ICC2.

The following steps will show you the usage of this GUI.

Page 3: GUI for DRV fix in ICC2

Step 2:

By selecting DRV Fix option, it will prompt you to select the input file and output file. Input file can be either “Nets File” or “Report File”. Report file can be any of “data_trans.rpt.gz or clock_trans.rpt.gz”. If the output file is not present, you can create one. After selecting the input and output files, press “Ok” button. Output file will be opened in the append mode, so already existing ecos in the selected output file(if any) will be prevailed.

Clicking Browse will give you the Browser window. Shown in one picture

• For selecting any file, double click on that name.

• For going to the previous directory, search for the “..” in the Directories list.

• You can paste the path of the file, instead browse.

Page 4: GUI for DRV fix in ICC2

Step 3:

Following GUI will be displayed. You can opt for either ‘Size Cell’ or ‘Add Buffer’ or ‘Clone Instance’ from this window.

Net and its corresponding cells wills be shown in the layout window. Depending upon that, we can opt one choice.

• At any time you can use the button ‘Remove Net Routing’ to add eco for removing the current net.• The button ‘grep’ will try to grep the current net in data_trans.rpt.gz or clock_trans.rpt.gz of tt0p9v corner and will display

the slack of it, if found.• Next and Previous buttons are used to traverse through the nets in the file.

As shown in the layout window, white annotation is the net, highlighted yellow instance is Driver and the highlighted Orange instances are sinks.

Page 5: GUI for DRV fix in ICC2

Step 3:

size_cell

If size cell has to be used, new reference name has to edited in the specify cell entry field and then press Apply button.By pressing the Apply button, you will be taken to the next net in the file, automatically.

When user wants to highlight net, it’s corresponding driver and sinks: user will edit the net name manually and press Refresh button.

Refresh

Page 6: GUI for DRV fix in ICC2

Step 3:

Add BufferWhen this option is selected, GUI will be transformed as shown below.

Terminals, New Cell and location of new cells to be added should be selected.

Page 7: GUI for DRV fix in ICC2

Location:

Either single buffer or inverter pair or buffer pair can be added. Either co-ordinates can be entered manually or can be obtained using the ‘Get X,Y’ button. First Buf/Inv’s Output term will be connected to the sinks, second Buf/inv’s input term will be connected to the driver(If buf/inv pair is opted).

After pressing ‘Get X,Y’ button, cursor changes and by clicking on the required location in the layout window, X and Y entry fields will be populated.

By checking the Second Buf/Inv tick box, inverter or buffer pair can be added based upon the value specified in the ‘New Cell’ entry field. Same procedure can be followed for populating the second entry fields.

By Pressing Ok button, eco will be written into the eco_file and next net in the file will be selected .

Add Buffer

Page 8: GUI for DRV fix in ICC2

Terminals

Either All Sinks or Particular Sinks of interest can be selected.

For All sinks, Radio Button ‘All Terminals’ needs to be clicked. If Terminals of interest are to be selected, Draw Terminals can be opted to get the terminals or terminals can be pasted in that entry field.

Draw Terminals:

Add Buffer

Terminals can be selected either using rectangular box or rectilinear box. By pressing the ‘Draw Terminals’ button, mouse tool will be changed and user needs to drag over the required sinks. The terminals in the dragged region will be selected and names will be listed in terminals entry.

Rectangular Box

New Cell:

By default the driver reference name will be displayed in the ‘New Cell’ entry field. This can be edited to the required value.

Page 9: GUI for DRV fix in ICC2

Location:

Either single buffer or inverter pair or buffer pair can be added. Either co-ordinates can be entered manually or can be obtained using the ‘Get X,Y’ button. First Buf/Inv’s Output term will be connected to the sinks, second Buf/inv’s input term will be connected to the driver(If buf/inv pair is opted).

After pressing ‘Get X,Y’ button, cursor changes and by clicking on the required location in the layout window, X and Y entry fields will be populated.

By checking the Second Buf/Inv tick box, inverter or buffer pair can be added based upon the value specified in the ‘New Cell’ entry field. Same procedure can be followed for populating the second entry fields.

By Pressing Ok button, eco will be written into the eco_file and next net in the file will be selected .

Add Buffer

Page 10: GUI for DRV fix in ICC2

Clone Instance

Step 3:

When this option is selected, GUI will be transformed as shown below.

Clone cell, postfix, Terminals and Location entries should be populated.

Page 11: GUI for DRV fix in ICC2

Terminals, Draw Terminals, ‘Get X,Y’

Procedure mentioned in slides 7 & 9 can be followed for populating these fields.

Clone Instance

Clone Cell

Reference name of the cloned cell should be mentioned in this field. By default the reference name of the driver will be present. It can be changed of interest.

Postfix

By default Postfix is clone, it can be edited. If the driver is already cloned, postfix will be changed.

Page 12: GUI for DRV fix in ICC2

Step 3:

Add Buffer On RouteWhen this option is selected, GUI will be transformed as shown below.

For Location: New Cell and location of new cells to be added should be given.Repeater Distance: First Distance and Repeater Distance is required.

Page 13: GUI for DRV fix in ICC2

Location:

Either single buffer or inverter pair can be added. Either co-ordinates can be entered manually or can be obtained using the ‘Get X,Y’ button.

After pressing ‘Get X,Y’ button, cursor changes and by clicking on the required location in the layout window, X and Y entry fields will be populated.

By checking the Second Buf/Inv tick box, inverter or buffer pair can be added based upon the value specified in the ‘New Cell’ entry field. Same procedure can be followed for populating the second entry fields.

By Pressing Ok button, eco will be written into the eco_file and next net in the file will be selected .

Add Buffer On Route

Page 14: GUI for DRV fix in ICC2

Repeater Distance:

First Distance and Repeater Distance should be specified.

Use this carefully. When fanout is single we will face no issue.

Add Buffer On Route

Prefix

By default Prefix will be DrvFix_[date]_ , it can be edited.

Cell

New cell added should be given. It should be either buffer or inverter.

Page 15: GUI for DRV fix in ICC2

Thank You!