gt-suite for cooling circuit & engine heat-balance gamma · gt-suite for cooling circuit &...

23
D e u t z A G , T h e r m a l & F l u i d E n g i n e e r i n g , T E - T T H a n s - C a r s t e n G ö t t s c h e - G ö t z e GTSUITE for cooling circuit & engine heatbalance Hans-Carsten Göttsche-Götze

Upload: others

Post on 21-Apr-2020

21 views

Category:

Documents


1 download

TRANSCRIPT

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

GT�SUITE for cooling circuit & engine heat�balanceHans-Carsten Göttsche-Götze

GT-SUITE for cooling circuit &

engine heat"balance225.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Deutz Applications for Diesel engines

AGRI PowerConstruction machines

Generator sets Automotive

GT-SUITE for cooling circuit &

engine heat"balance325.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Engine spec with key components from customer

GT-SUITE for cooling circuit &

engine heat"balance425.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Use of GT Suite MP

Cooling system development

Customer data to Deutz

Engine spec

Vehicle package

Operation limits

Deutz Cooling Team

Heat rejection, Cooler

size, coolant flow

Thermostat setting

System configuration

Cooling components

Diameters, Roughness

Maps of pump, hx, Fan

Thermostat valve curve

Pressure losses

Data to Customer

Heat Rejection

Coolant flow

Charge Air flow

GT-SUITE for cooling circuit &

engine heat"balance525.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Development structure

Hx temperature difference

Required coolant flow

First engine heat balance

First model w/o hxw/o pump map

pressure level, losses, flow distribution

Experience

GT-SUITE for cooling circuit &

engine heat"balance625.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Engine coolant circuit

Thermostat

p

p

p

p

p

Measurement required p flow

∆p

∆p

∆p

∆p

∆p

flow

flow

flow

∆p

p

EGR

Oil

Radiator

Measure requirements for coolant system calculation

Known ∆p, flow

GT-SUITE for cooling circuit &

engine heat"balance725.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Development structure

Hx temperature difference

Required coolant flow

First engine heat balance

First model w/o hxw/o pump map

pressure level, losses, flow distribution

Pump map and more detailed model

CFD calculations

testing resultsInteraction with testing

Experience

GT-SUITE for cooling circuit &

engine heat"balance825.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

CFD of difficult geometries

Result: pressure resistance

GT-SUITE for cooling circuit &

engine heat"balance925.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Example: full circuit w/o heat exchangers

Result: pump performance

coolant flow distribution

Engine block

Oil

EGR

Pump

Thermostat

GT-SUITE for cooling circuit &

engine heat"balance1025.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Development structure

Hx temperature difference

Required coolant flow

First engine heat balance

First model w/o hxw/o pump map

pressure level, losses, flow distribution

Pump map and more detailed model

CFD calculations

testing resultsInteraction with testing

Experience

Circuit with HX: Oil, EGR, coolant, CACEngine test results

Confirmation of heat rejection and system performance

GT-SUITE for cooling circuit &

engine heat"balance1125.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Heat Balance Schematic

OilQ Coolant

Fuel

Exhaust

after Turbine

Radiation

Convection

EGR

Power

Q CACFriction

Convection

Coolant

GT-SUITE for cooling circuit &

engine heat"balance1225.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Heat balance calc for full circuit

Principle:

Q_fuel = Power + Q_Exhaust + Q_Coolant + Q_CAC + Q_amb= BSFC x Power x Fuel Heat/3600000

Q_Exhaust = f( heat cap Exh, mass flow, Temperature after Turbine )

Q_CAC = f( heat cap Air, mass flow, Temperature after compressor )

Q_amb ~ 4%Q_fuel

Q_Coolant = Q_Engine + Q_oil + Q_EGR

Q_EGR = f( heat cap Exh_EGR, mass flow, Temp diff over EGR cooler)

EGR mass flow = f( EGR rate, air mass flow )

Q_Oil = f( heat cap, mass flow, Temp diff over oil cooler)

GT-SUITE for cooling circuit &

engine heat"balance1325.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Measure requirements for heat balance

Measurement required Τ flow

RA

D

EG

R

CAC

Τ

flowΤ

BSFC

Τ

T oil sumpΤ

flow

Condition with and w/o EGR

Vol eff 0 Vol eff

GT-SUITE for cooling circuit &

engine heat"balance1425.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Calculation of heat rejection with GT controls

6 value maps out of

measures

4 condition values

out of case setup

Result out:

Q_Coolant

Q_CAC

EGR rate

Maped Values XYZ points

GT-SUITE for cooling circuit &

engine heat"balance1525.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Map generation with XYZ points

Example: charge air flow over speed and BMEP

23.00

20.00

15.00

10.00

1.80

5.00

1100 1250 1500 1750 2000 2200

GT-SUITE for cooling circuit &

engine heat"balance1625.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Full cycle with heat exchangers

Result: Coolant flow

Temperature distribution

System behavior

Oil cicuit, EGR flow, CAC flow, Cooling Air flow

GT-SUITE for cooling circuit &

engine heat"balance1725.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Full cycle with heat exchangersDetail: Oil module

GT-SUITE for cooling circuit &

engine heat"balance1825.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Full cycle with heat exchangersDetail: Cooling pack

Air side of water circuit

Cooling air

Charge air

Coolant

GT-SUITE for cooling circuit &

engine heat"balance1925.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Development structure

Hx temperature difference

Required coolant flow

First engine heat balance

First system w/o hxw/o map pump

pressure level, losses, flow distribution

Pump map and more detailed circuit

CFD calculations

testing resultsInteraction with testing

Experience

Circuit with HX: Oil, EGR, coolant, CACEngine test results

Confirmation of heat rejection and system performance

Circuit with couplingGT Power calculation More detailed heat distribution to oil

GT-SUITE for cooling circuit &

engine heat"balance2025.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Split coupling with GT Power: model 4cyl-2V

Block HeadOilReading Cool AirCoolant CA EGR Control

GT-SUITE for cooling circuit &

engine heat"balance2125.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Result of coupling with GT Power

GT-SUITE for cooling circuit &

engine heat"balance2225.11.2009

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Use of GT Suite MP

Cooling system deveopment

Customer data to Deutz

Engine spec

Vehicle package

Operation limits

Deutz Cooling

Heat rejection

Hx size, ATB, coolant flow

Thermostat setting

System configuration

Cooling components

Diameters, Roughness

Maps of pump, hx, Fan

Thermostat valve curve

Pressure losses

Data to Customer

Heat Rejection

Coolant flow

Charge Air flow

Deutz AG, Thermal&Fluid Engineering, TE-TT

Hans-Carsten Göttsche-Götze

Vielen Dank