gse z13s z13 ga2 - gse young professionalsgsebelux.com/system/files/gse z13s z13 ga2.pdf · china...

44
© 2016 IBM Corporation GSE z Systems workgroup meeting 9/3/16 Jan Tits – IBM - [email protected] z13s and z13 GA2 Technical Overview IBM z13s IBM z13

Upload: others

Post on 23-May-2020

21 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation

GSE z Systems workgroup meeting 9/3/16

Jan Tits – IBM - [email protected]

z13s and z13 GA2 Technical Overview

IBM z13s

IBM z13

Page 2: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 2

The following are trademarks of the International Business Machines Corporation in the United States, other countries, or both.

The following are trademarks or registered trademarks of other companies.

* All other products may be trademarks or registered trademarks of their respective companies.

Notes: Performance is in Internal Throughput Rate (ITR) ratio based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput improvements equivalent to the performance ratios stated here. IBM hardware products are manufactured Sync new parts, or new and serviceable used parts. Regardless, our warranty terms apply. All customer examples cited or described in this presentation are presented as illustrations of the manner in which some customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics will vary depending on individual customer configurations and conditions. This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the information may be subject to change without notice. Consult your local IBM business contact for information on the product or services available in your area. All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. Information about non-IBM products is obtained Sync the manufacturers of those products or their published announcements. IBM has not tested those products and cannot confirm the performance, compatibility, or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. Prices subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography.

Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries. Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. UNIX is a registered trademark of The Open Group in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office. IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency, which is now part of the Office of Government Commerce.

Not all common law marks used by IBM are listed on this page. Failure of a mark to appear does not mean that IBM does not use the mark nor does it mean that the product is not actively marketed or is not significant within its relevant market.

Those trademarks followed by ® are registered trademarks of IBM in the United States; all others are trademarks or common law marks of IBM in the United States.

For a more complete list of IBM Trademarks, see www.ibm.com/legal/copytrade.shtml: *BladeCenter®, CICS®, DataPower®, DB2®, e business(logo)®, ESCON, eServer, FICON®, IBM®, IBM (logo)®, IMS, MVS, OS/390®, POWER6®, POWER6+, POWER7®, Power Architecture®, PowerVM®, PureFlex, PureSystems, S/390®, ServerProven®, Sysplex Timer®, System p®, System p5, System x®, z Systems®, System z9®, System z10®, WebSphere®, X-Architecture®, z13™, z Systems™, z9®, z10, z/Architecture®, z/OS®, z/VM®, z/VSE®, zEnterprise®, zSeries®

Trademarks

Page 3: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 3

z Systems z13s and z13 GA2

Page 4: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 4

IBM z13s and z13 platform positioning

•  The world’s premier transaction and data engine now enabled for the mobile generation

•  The integrated transaction and analytics system for right-time insights at the point of impact

•  The world’s most efficient and trusted cloud system that transforms the economics of IT

Platform Core Capabilities:

Transaction Processing

Data Serving

Mixed Workloads

Operational Efficiency

Trusted and Secure Computing

Reliable, Available, Resilient

Virtually Limitless Scale

Now extended to enterprises of all sizes creating a new entry point to z13 technology

Draft

Page 5: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 5

z Systems Processor Roadmap

Core 0

L3_0

L3_1

L2

CoPMCU

L2

Core 1

L3_0

L3_1

Core 2

L2

CoP GX

L2

Core 3

L3_0 Controller

L3_1 Controller

MCIOs

MCIOs

GXIOs

GXIOs

L3B

L3B

Core 0

L3_0

L3_1

L2

CoPMCU

L2

Core 1

L3_0

L3_1

Core 2

L2

CoP GX

L2

Core 3

L3_0 Controller

L3_1 Controller

MCIOs

MCIOs

GXIOs

GXIOs

L3B

L3B

z196/z114 09/2010

zEC12/zBC12 08/2012

z10EC/z10BC 02/2008

z13/z13s 01/2015

Leadership Single Thread, Enhanced Throughput

Improved out-of-order

Transactional Memory

Dynamic Optimization

2 GB page support

Step Function in System Capacity

Top Tier Single Thread Performance,System Capacity

Accelerator Integration

Out of Order Execution

Water Cooling

PCIe I/O Fabric

RAIM

Enhanced Energy Management

Leadership System Capacity and Performance

Modularity & Scalability

SMT (2-way)

Double instruction bandwidth

SIMD

Business Analytics Optimized

Workload Consolidation and Integration Engine for CPU

Intensive Workloads

Decimal FP

Infiniband

64-CP Image

Large Pages

Shared Memory

65 nm

22 nm 32 nm

45 nm

4-co

re c

hip

6-co

re c

hip

8-co

re c

hip

4-co

re c

hip

Page 6: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 6

I/O Subsystem, Parallel Sysplex, STP, Security

New PCIe Gen3 I/O fanouts with 16 GBps Buses

LCSS increased from 4 to 6

4th Subchannel Set per LCSS

Maximum number of I/O Devices (subchannels) per channel increased from 24K to 32K for all z13 FICON features

FICON Enhancements

SR-IOV support for RoCE

New Integrated Coupling Adapter (ICA SR ) for coupling links

Support for up to 256 coupling CHPIDs per CPC

CFCC Level 20

Crypto Express5S and Cryptographic enhancements with support for 85 Domains

STP Enhancements

System, Processor, Memory

Five hardware models

Eight core 22nm PU SCM

Up to 141 processors configurable as CPs, zIIPs, IFLs, ICFs, or optional SAPs

Increased Uni processor capacity

Up to 30 sub capacity CPs at capacity settings 4, 5, or 6

CPC Drawers and backplane Oscillator

SMT (for IFLs and zIIPs only) and SIMD

Enhanced processor/cache design with bigger cache sizes

Up to 10 TB of Redundant Array of Independent Memory (RAIM)

CPC Drawer/Memory Affinity

LPARs increased from 60 to 85

RAS, Other Infrastructure Enhancements

IBM zAware for Linux on z Systems (June 23, 2015) System Control Hub (SCH). Replaces BPH

New N+2 ‘radiator’ design for Air Cooled System Rack-Mounted Support Elements in the CPC

Key Locks for doors Rack-mounted HMCs for customer supplied rack

Support for ASHRAE Class A2 datacenter TKE 8.0 LICC

z13 Functions and Features (GA1 Driver Level 22)

IBM z13 GA1

Page 7: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 7

I/O Subsystem, Parallel Sysplex, STP, Security

New FICON functions* •  Export/Import physical port WWPNs for FCP •  Fiber channel read diagnostic parameters (RDP)

Extended Link Services (ELS)

OSA Enhancements* •  OSA ICC Secure Socket Layer (SSL) support •  OSA ICC Concurrent MCL’s for OSC CHPIDs

Shared Memory Communications–Direct (SMC-D)*

Enhanced Flash Express (R/W Cache 4 GB)*

CFCC Level 21* •  Maintain Entry and Element Counts •  CFCC Dump Reasons •  CFCC set SLCP Event Type 11

Crypto Express5S* •  Format Preserving Encryption (FPE) in FPGA

Stage 2 •  DK Phase 4 •  CCA verb algorithm currency & interoperability •  EMF simplification support •  EP11 Stage 3, PKCS 11

•  Regional Crypto Enablement (RCE) for Greater China Group (GCG) only*

System, Processor, Memory

Dynamic Partition Manager for Linux and KVM*

z Appliance Container Infrastructure (zACI)*

z/VSE Network Appliance using the z Appliance Container Infrastructure (zACI)*

IBM zAware in zACI Partition Mode*

LPAR Group Absolute Capping*

CPUMF sampler w/o PEMode enablement*

SNMP/BCPii performance enhancements*

RAS, Other Infrastructure Enhancements

Enhanced Console Assisted Recovery*

TKE 8.1 LICC and Rack-mounted TKE*

z13 Functions and Features (GA2 Driver Level 27)

IBM z13 GA2

* Note: new functional items available on z13 GA2 and z13s

Page 8: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 8

System, Processor, Memory

2 models – N10, N20 (N20 with one or two CPC drawers)

8 core 22nm PU SCM (6, 7 active cores per PU SCM)

Up to 20 configurable PUs as CPs, zIIPs, IFL, ICFs, or optional SAPs (up to 6 CPs)

Increased uni-processor capacity

156 Capacity settings

CPC Drawers and backplane Oscillator

SMT (for IFLs and zIIPs only) and SIMD

Enhanced processor / cache design with bigger cache sizes

Up to 4 TB of Memory protected by Redundant Array of Independent Memory (RAIM) – Up to 984 GB in model N10

CPC Drawer/Memory Affinity

Up to 40 LPARs (increased from 30 on zBC12)

IBM Dynamic Partition Manager f

z Appliance Container Infrastructure (zACI)

LPAR Group Absolute Capping

CPUMF sampling w/o PEMode enablement

RAS, Other Infrastructure Enhancements

IBM zAware for z/OS & Linux System Control Hub (SCH). Replaces BPH

STP Enhancements Rack-Mounted Support Elements in the CPC

Key Locks for doors Tower & Rack-mounted HMCs (in customer supplied rack)

Support for ASHRAE Class A3 datacenter TKE 8.1 LICC and Rack-mounted TKE

z13s Functions and Features (GA Driver Level 27)

X IBM z13s

I/O Subsystem, Parallel Sysplex, STP, Security

New PCIe Gen3 I/O fanouts with 16 GBps Busses

LCSS increased from 2 to 3

3 Subchannel Sets per LCSS

I/O Devices per channel increased from 24K to 32K for all z13s FICON features

FICON Express16S and FICON Enhancements

OSA Enhancements

SR-IOV support for RoCE

Shared Memory Communications–Direct (SMC-D)

Enhanced Flash Express (R/W Cache 0.5 GB)

Integrated Coupling Adapter (ICA SR ) for coupling links

CFCC Level 21

Crypto Express5S and Crypto enhancements

Page 9: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 9

!  6 or 7 active cores (PUs) per chip (8 cores total) – 4.3 GHz (vs. 4.2GHz zBC12) – L1 cache/ core

• 96 KB I-cache • 128 KB D-cache

– L2 cache/ core • 2M i+2M d Byte eDRAM split private L2

cache !  Single Instruction/Multiple Data (SIMD) !  Single thread or 2-way simultaneous multithreading

(SMT) operation !  Improved instruction execution bandwidth:

– Greatly improved branch prediction and instruction fetch to support SMT

– Instruction decode, dispatch, complete increased to 6 instructions per cycle

– Issue up to 10 instructions per cycle – Integer and floating point execution units

!  On chip 64 MB eDRAM L3 Cache – Shared by all cores

!  I/O buses – One InfiniBand I/O bus – Two PCIe I/O buses

!  Memory Controller (MCU) – Interface to controller on memory DIMMs – Supports RAIM design

!  Chip Area –  678.8 mm2 –  28.4 x 23.9 mm –  17,773 power pins –  1,603 signal I/Os

!  14S0 22nm SOI Technology

–  17 layers of metal –  3.99 Billion Transistors –  13.7 miles of copper

wire

z13s Processor Unit (PU) chip details

Page 10: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 10

0

1000

2000

3000

4000

5000

6000

7000

1064* +36%

661* +43%

782* +18%

0

1500 2000 2500 3000 3500

MH

z, P

CI*

4000 4500

2006 2008 2011 2013

z10 BC 65 nm SOI

3.5 GHz 5 CPs (10 IFLs) High-frequency

core

z114 45 nm SOI

3.8 GHz (+8.6%) 5 CPs (10 IFLs)

NOTE: MIPS Tables are NOT adequate for making comparisons of z Systems processors in proposals

z13s continues the CMOS Mainframe heritage

zBC12 32 nm SOI

4.2 GHz (+10.5%) 6 CPs (13 IFLs)

2016

1430* +34%

z13s 22 nm SOI

4.3 GHz (+2.4%) 6 CPs (20 IFLs)

SMT & SIMD Up to 4 TB memory

462*

z9 BC 90 nm SOI

1.4 GHz 4 CPs – 7 CPs

*Full capacity uniprocessor

Page 11: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 11

Simultaneous Multithreading (SMT) on z13s !  SMT support one or two threads to execute on a zIIP or IFL. !  Capacity improvement is variable depending on workload. For

AVERAGE workloads the estimated capacity of a z13s zIIP/IFL with exploitation of the SMT option is: ‒  A z13s zIIP is up to 68% greater than a zBC12 zIIP ‒  A z13s IFL is up to 61% greater than a zBC12 IFL ‒  A z13s zIIP is up to 129% greater than a z114 zIIP ‒  A z13s IFL is up to 119% greater than a z114 IFL

!  SMT exploitation: ‒  z/VM V6.3 + PTFs, or z/VM 6.4 for IFLs (GA 4Q2016) ‒  z/OS V2.1 + PTFs, or z/OS V2.2 in an LPAR for zIIPs ‒  KVM for IBM z V1.1.1 (3/2016) ‒  For recommended Linux distribution levels refer to: http://

www.ibm.com/systems/z/os/linux/resources/testedplatforms.html !  The use of SMT mode can be enabled on an LPAR by LPAR basis via

operating system parameters. ‒  When enabled, z/OS can transition dynamically between single

thread mode and SMT mode with operator commands. !  Notes: SMT is designed to deliver better overall capacity

(throughput) for many workloads. Thread performance (instruction execution rate for an individual thread) may be faster running in single thread mode.

Which approach is designed for the highest volume*** of traffic? Which road is faster? (***) Two lanes at 50 carry 25% more

volume if traffic density per lane is equal

80 50

Page 12: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 12

Instruction pool Data pool

Results

Instruction pool Data pool

Results

!  OS/Hypervisor & Software Support for SIMD: − z/OS V2.2, or z/OS: 2.1 + PTFs − Linux: IBM is working with its Linux Distribution partners to

support new functions/features − z/VM 6.4 (4Q2016), or z/VM 6.3 + PTFs − KVM for IBM z V1.1.1 enables guests to exploit SIMD (1Q2016) − Compiler exploitation

•  IBM Java 8 •  z/OS XL C/C++ V2R1M1, V2.2 (added AUTOSIMD option) •  XL C/C++ for Linux on z Systems, V1.1 •  Enterprise COBOL for z/OS v5.2 •  Enterprise PL/I for z/OS v4.5

Workloads Java 8

C/C++Compiler built-ins

for SIMD operations (z/OS and Linux on z

Systems)

MASS & ATLAS Math Libraries

(z/OS and Linux on z Systems)

SIMD Registers and Instruction Set

MASS - Mathematical Acceleration Sub-System / ATLAS - Automatically Tuned Linear Algebra Software

SIMD Vector Processing Support on z Increase  throughput  with  IBM  CPLEX  

Op9mizer  V12.6.1

Page 13: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 13

!  Machine Type: 2965 !  2 Models Single frame, air cooled:

–  N10 and N20 •  N20 available as one- or two- processor drawer model •  The 2nd drawer in the N20 is only driven by I/O and/or memory requirements

–  Non-raised floor option available –  Overhead Cabling and DC Power Options

!  Processor Units (PUs) –  13 PU cores (model N10) or 26 PU cores (model N20) –  Up to 3 standard SAPs per system (2 for model N10, 3 for model N20) –  2 spares designated for Model N20 –  1 Integrated firmware processor (IFP) –  Dependent on the H/W model - up to 10 or 20 PU cores available for

characterization •  CP, IFLs, ICFs, zIIPs, optional SAPs, IFP

•  156 capacity settings !  Memory

–  Up to 4 TB for System including •  System minimum = 64 GB •  40 GB fixed HSA separately managed •  RAIM standard •  Maximum for customer use 4056 GB (Model N20-2 drawer) •  Increments of 128 to 256 GB •  Flash Express Red/Write Cache in HSA (0.5 GB)

!  I/O –  Support for non-PCIe Channel features (max one I/O drawer via carry forward) –  PCIe Gen3 channel subsystem

•  Up to 64 PCIe Channel features –  Up to 3 Logical Channel Subsystems (LCSSs)

!  STP - optional (No ETR)

z13s Overview

z13s

Model PUs Max Mem

N10 1

Drawer 10 984

GB

N20 1

Drawer 20 2008

GB

N20 2

Drawers 20 4056

GB

Page 14: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 14

More memory makes a difference

!  Improve transaction response times and increase transaction rates (DB2, IMS, CICS) ! Reduce CPU usage and improve CPU scaling.

! The former saves money, the latter adds flexibility. ! Reduce Batch window, shorter elapsed times for jobs. ! Simplify memory management.

! Skills now spent tuning memory can be applied to driving business value. !  Improve availability.

! Tolerate larger memory and I/O workload spikes. Enable faster recovery. ! New opportunities for in-memory computing (Analytics)

! Dramatic reduction in response time by avoiding I/O wait ! Deploy more of today’s memory-hungry workloads with IBM z Systems industry-

leading security and lower total cost of ownership (Larger Java heaps, IBM MQ DB2 BLU, ETL Processing, Cognos cubing, large in memory databases, etc…)

Large memory can deliver significant performance improvements for Linux

Workloads Linux users are accustomed to running large databases: " DB2, Oracle footprint

" Cognos Cubing "  In Memory Analytics

Benefits of Configuring More Memory in the z/OS Software Stack document: http://www.redbooks.ibm.com/redpieces/abstracts/redp5238.html?Open

Page 15: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 15

Z01 Z02 Z03 Z04 Z05 Z06

Y01 Y02 Y03 Y04 Y05 Y06

X01 X02 X03 X04 X05 X06

W01 W02 W03 W04 W05 W06

V01 V02 V03 V04 V05 V06

U01 U02 U03 U04 U05 U06

T01 T02 T03 T04 T05 T06

S01 S02 S03 S04 S05 S06

R01 R02 R03 R04 R05 R06

Q01 Q02 Q03 Q04 Q05 Q06

P01 P02 P03 P04 P05 P06

O01 O02 O03 O04 O05 O06

N01 N02 N03 N04 N05 N06

M01 M02 M03 M04 M05 M06

L01 L02 L03 L04 L05 L06

K01 K02 K03 K04 K05 K06

J01 J02 J03 J04 J05 J06

I01 I02 I03 I04 I05 I06

H01 H02 H03 H04 H05 H06

G01 G02 G03 G04 G05 G06

F01 F02 F03 F04 F05 F06

E01 E02 E03 E04 E05 E06

D01 D02 D03 D04 D05 D06

C01 C02 C03 C04 C05 C06

B01 B02 B03 B04 B05 B06

A01 A02 A03 A04 A05 A06

1-way 2-way 3-way 4-way 5-way 6-way

Specialty Engine

Specialty Engine

Specialty Engine

Specialty Engine

Specialty Engine

Specialty Engine

Additional engines available on the N20

!  Improvement over zBC12 !  A01 Uniprocessor: 80 PCIs (+ 60%) !  Z01 Uniprocessor: 1,430 PCIs (+ 34%) !  Largest z/OS capacity – Z06: 7,123 PCIs (+ 44%) !  Full Linux capacity – 20-way: 18,335 PCIs (+ 110%)

!  Granularity levels similar to zBC12 to facilitate upgrades and incremental growth

!  26 capacity levels x 6 CPs = 156 settings !  Nomenclature: XYY

–  X = Capacity level (A-Z) –  YY= Number of processors –  A00 = ICF or IFL only (zero CPs)

!  Processor Value Unit (PVU) for IFL = 100 !  Any to any capacity upgrade/downgrade capability

within the Model !  CBU capability from smallest to largest capacities

within the Model !  On/Off CoD within the Model

z13s capacity matrix

Specialty Engine

Specialty Engine

Specialty Engine

Specialty Engine # +10 more specialty engines

PCI: Processor Capacity Index Additional engines available on the N10/N20

Page 16: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 16

On/Off CoD with tokens No expiration Capacity - MSU % - # Engines Tokens - MSU days - Engine days

Pre-paid

Capacity for Planned Event (CPE)

On/Off CoD with tokens 180 days expiration Capacity - MSU % - # Engines Tokens - MSU days - Engine days

On/Off CoD 180 days expiration Capacity - MSU % - # Engines

Using pre-paid unassigned capacity up to the limit of the HWM No expiration Capacity - MSU % - # Engines

Post-paid

Capacity Backup (CBU)

Temporary Upgrade

Billable Capacity (On/Off CoD)

Replacement Capacity

Permanent Upgrade (CIU)

Capacity on Demand

z13s and z13 Basics of Capacity on Demand Upgrade to z13s: Installed On Demand records: zAAPs are converted to zIIPs and the record is migrated staged. Upgrade to z13s: Staged On Demand records: Records with zAAPs are rejected. Others are migrated staged.

Page 17: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 17

z10 BC z9 BC

z114

zBC12

System I/O Bandwidth (RAW)

6-Way Engines

512 GB 1064

72 GB/Sec

21.6 GB/Sec

Notes: 1.  Capacity shown is for CPs only 2.  z9BC, z10BC, z114, zBC12, and z13s can

have additional PUs which can be used as Speciality Engines

3. PCI – Processor Capacity Index

5-Way

4-Way

782 661 462

System design optimized for digital business

64 GB 256 GB Memory

4TB

PCI for 1-Way

1430

128 GB/Sec

z13s

352 GB/Sec

Page 18: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 18

SCH (x2)

z13s Model N20 (1 CPC drawer) – Under the covers

Internal Batteries (optional)

Power Supplies

PCIe I/O Drawer

1 x CPC Drawer + slot for 2nd CPC

Drawer Memory & HCAs

Ethernet cables for internal System LAN connecting Flexible Service Processor

(FSP) cage controller cards (not shown)

PCIe I/O drawers

Rear View Front View

Monitors & Keyboards

for SEs

Support Elements

Page 19: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 19

LPAR Group Absolute Capping

! Next step in partition capping options available on z13 GA2 and z13s

! Follow on to LPAR Absolute Capping, using a similar methodology to enforce: –  Customer licensing –  Non-z/OS partitions where group soft capping is not an option –  z/OS partitions where ISV does not support software capping

! A group name, processor capping value, and partition membership are specified at HW console:

–  Set an absolute capacity cap by CPU type on a group of LPARs –  Allows each of the partitions to consume capacity up to their individual limits as long as the group's

aggregate consumption does not exceed the group absolute capacity limit –  Includes updated SysEvent QVS support (used by vendors who implement SW pricing) – Only shared partitions managed in these groups –  Can specify caps for one or more processor types in the group

•  Specified in absolute processor capacity (eg 2.5 processors) –  Use Change LPAR Group Controls (same panels used for software group defined capacity)

Page 20: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 20

z13s I/O Infrastructure

Page 21: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 21

z Systems I/O interface evolution

z9 z196 z10

zEC12-zBC12 z196-z114

eSTI* (IBM) InfiniBand

Extended Link (processor to PCIe

I/O Drawer, I/O Drawer)

I/O Cage/drawer

Backplane mSTI (IBM)

ISC (IBM)

InfiniBand Coupling Link

PCI Express Gen2

PCI Express Gen2

InfiniBand

InfiniBand

z13 z13s

PCI Express Gen3

PCI Express Gen3

PCI Express Gen3,

InfiniBand

(*) STI – Self-Timed Interconnect

Page 22: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 22

z13s “New Build” I/O and MES Features Supported

! Features – PCIe I/O drawer – FICON Express16S (SX and LX, 2 SFPs, 2 CHPIDs) – FICON Express8S (SX and LX, 2 SFPs, 2 CHPIDs) – OSA-Express5S

•  10 GbE LR and SR (1 SFP, 1 CHPID) •  GbE SX, LX, and 1000BASE-T (2 SFPs, 1 CHPID)

– 10 GbE RoCE Express (2 supported SR ports) – zEDC Express – Crypto Express5S – Flash Express (Technology Refresh)

!  Integrated Coupling Adapter (ICA) Fanout –  ICA SR two 8 GBps PCIe Gen3 Coupling Link

!  InfiniBand Coupling Feature Fanouts – HCA3-O two 12x 6GBps InfiniBand DDR Coupling Links – HCA3-O LR four 1x 5Gbps InfiniBand DDR or SDR Coupling Links

PCIe I/O drawer

32 I/O slots

New Build Features

Page 23: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 23

! Features – PCIe I/O drawer – FICON Express8S (SX and LX, 2 SFPs, 2 CHPIDs) – OSA-Express5S (All) – OSA-Express4S (All) – 10 GbE RoCE Express (Both ports supported on z13s) – zEDC Express – Flash Express – Not Supported: Crypto Express4S

! Features – I/O drawer (No MES adds) – FICON Express8 (SX and LX, 4 SFPs, 4 CHPIDs) – Maximum of One 8 Slot I/O Drawer – Not Supported: ESCON, FICON Express4, OSA-Express3,

ISC-3, Crypto Express3

!  InfiniBand Coupling Features (Fanouts)

– HCA3-O two 12x 6GBps InfiniBand DDR Coupling Links – HCA3-O LR four 1x 5Gbps InfiniBand DDR or SDR Coupling Links – NOT Supported: HCA2-O 12x, HCA2-O LR 1x InfiniBand Coupling Links

Carry Forward Features z13s “Carry Forward” I/O Features Supported

PCIe I/O drawer 32 I/O slots

I/O drawer 8 I/O slots

Page 24: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 24

Flash Express on z13s and z13 GA2 ! Typical Client Use Cases:

– Improve availability and performance during workload transition and spikes – Faster, less disruptive diagnostics with faster first failure data capture time – Less paging with use of pageable large pages for Java or DB2 – Resilient solution for overflow of MQ shared queues in Coupling Facility

!  IBM Flash Express read/write cache – on IBM z13s & z13 GA2 – A read/write cache greatly increases performance by allowing customer data

to be stored temporarily in a cache located in the system's Hardware System Area (HSA) RAM:

•  0.5GB of HSA space reserved on z13s and 4GB on z13 GA2 – Extended-asynchronous-data-mover (EADMF) operations would complete

from a partition's perspective immediately after data is moved to/from HSA cache, long before IBM Flash Express operations have completed.

!  IBM Flash Express Dynamic Fan Speed Adjustment – Allows the I/O Processor to periodically communicate the IBM Flash Express

temperatures to power/thermal code running on an FSP which adjusts the fans to raise the flow rate when IBM Flash Express traffic has risen to the point that the SSD temperature is at risk of causing throttling.

Page 25: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 25

Hardware Crypto support in z Systems

CPACF

Rack Mounted or Tower

Trusted Key Entry (TKE 8.1)

z13 CPC Drawers

Smart Cards

z13 PU SCM

Crypto Express5S

Smart Card Readers

z13s CPC Drawers

z13s PU SCM

PCIe I/O drawers

PCIe I/O drawers

z13 z13s

Page 26: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 26

Integrated Coupling Adapter (ICA SR)

!  Integrated Coupling Adapter SR (ICA SR) Fanout in the CPC drawer

!  Recommended for Short Distance Coupling z13/z13s to z13/z13s, not available on older servers

!  No performance degradation compared to Coupling over Infiniband 12X IFB3 protocol

!  Hardware Details – Short reach adapter, distance up to 150 m – Up to 40 ports (z13) or 16 ports (z13s) maximum –  IOCP Channel Type = CS5

!  Feature code 0172, 2 ports per adapter – Up to 4 CHPIDs per port, 8 per feature, 8 buffers

(i.e. 8 subchannels) per CHPID !  ICA requires new cabling for single MTP connector

– Differs from 12X Infiniband split Transmit/Receive connector

!  Requirements – CF: z13/z13s; z/OS: z13/z13s – z/OS V2.2, V2.1, V1.13, or V1.12 with PTFs for APARs OA44440 and OA44287

Page 27: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 27

A Look Back: Parallel Sysplex Hardware Support

CFLEVEL 18

Performance enhancements for dynamic

structure size alters and DB2 GBP management

Elapsed time

improvements when dynamically altering cache

structure size

Non-Disruptive CF dump capture and collection _________________

Coupling Link Characteristics Reporting

to z/OS for sysplex monitoring and tuning

Up to 64 1X IFB links _________________

Broadband security

Improvements for STP Improved NTP Commands

panel on HMC/SE

CFLEVEL 19

Coupling Thin Interrupts for improved performance in environments which are sharing Coupling Facility

engines

Exploitation of Flash Express for improved

WebSphere MQ resiliency handling WebSphere MQ shared queue workflows __________________

Last generation to support Legacy Coupling (HCA2-O fanouts for 1X IFB & 12X

IFB, ISC-3) __________________

Service Element (SE) Time

Accuracy Improvements

Last generation to support STP Mixed CTNs

CFLEVEL 20

Large Memory Support: Improved

availability for larger CF cache structures

and data sharing performance with larger DB2 Group

Buffer Pools _________________

Integrated Coupling Adapter (ICA SR) for

Short Distance Coupling

Up to 256 coupling CHPIDs per CPC

_________________

Hardware Management Console

(HMC) STP Panel Enhancements

CFLEVEL 21

Enable systems management

applications to collect valid CFCC level information

________________

Integrated Coupling Adapter (ICA SR) for Short Distance

Coupling _______________

Up to 256 coupling CHPIDs per CPC* ______________

Enhanced Console Assisted Recovery

CFLEVEL 17

Support for up to 2047 structures per CF Image to enable

more data sharing groups

_________________

Improved service times with 12x IFB3

Protocol

Up to 32 subchannels per CHPID for 1X IFB _________________

Support for Mixed

Coordinated Timing Network (CTN)

enabling migration to STP

STP recovery enhancement

z13 GA2 / z13s

z13 zEC12 GA2 / zBC12

z196 GA2 / z114 zEC12

Page 28: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 28

Shared Memory Communications -Remote and -Direct

SMC-R* and SMC-D* enabled platform

OS image 3 (z/OS) OS image 2 (z/OS)

Shared Memory Communications via DMA (SMC-D using vPCI ISM)

Client

Shared Memory Communications via RDMA (SMC-R)

SMC

RDMA enabled (RoCE)

Clustered Systems: Multi-Tier Application Solution

SMC-R* enabled platform

Virtual server instance

shared memory

Sockets

SMC

Client & Server

shared memory

Sockets

OS image 1 (z/OS)

shared memory

Server Sockets

SMC

RoCE RoCE ISM ISM VCHID

•  Network latency time reduction •  Potential CPU savings •  High scalability & throughput •  VLAN isolation

•  Transparent to applications •  Resiliency / High availability •  Secure internal communications •  Response time improvements

*SMC-R requires z/OS 2.1 + PTFs or higher; SMC-D requires z/OS 2.2 + PTFs

Page 29: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 29

Services

Sel

f Hea

ling

Applications

OS Man

agem

ent

HW

“A zACI appliance is an integration of operating system, middleware and software components that work autonomously and provide core services

and infrastructures focusing on consumability and security”

z Appliance Container Infrastructure (zACI)

!  “Encapsulated” Operating Systems

! Remote APIs (RESTful) and web interfaces

! Embedded monitoring and self-healing

! Tamper-protected

! Protected Intellectual Property of appliance components

! Tested/Qualified by provider for a specific use case

Page 30: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 30

z13/z13s IBM zAware host

Linux on z

Systems

z/OS IBM

zAware

zACI Mode

Partition

Linux on z

Systems

Linux on z

Systems

z/OS

IBM zAware Web GUI to monitor

results

!  New zACI Mode Partition !  Identify unusual system behavior of Linux on z Systems images !  Monitors syslog* from guest or native image in real time !  Improved analytics for z/OS message logs !  Upgraded internal database for improved RAS !  Completely rewritten UI, including heat map views

z/VM

IBM zAware for z/OS and Linux on z Systems

z/OS

IBM zAware monitored client

Page 31: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 31

Dynamic Partition Manager – At a Glance

Dynamic Partition Manager Mode A CPC can be in Standard PR/SM mode or Dynamic Partition Manager mode. Enable Dynamic Partition Manager mode with first IML.

Linux only A CPC running in Dynamic Partition Manager mode is Linux only. No z/OS, z/VM, z/VSE, z/TPF, IBM zAware support. FCP Storage only.

Simplification Provide simplified, consumable, enhanced Partition life-cycle and integrated dynamic I/O management capabilities.

Cloud Provides the technology foundation that enables IaaS and secure, private Clouds.

FIE Initial focus on First In Enterprise (FIE) customers with support for existing clients in a later stage.

“Dynamic Partition Manager” provides simplified z Systems hardware and virtual

infrastructure management including integrated dynamic I/O management for FIE

customers that run KVM on z as a hypervisor and/or Linux on z as an Partition-hosted

operating system.”

Page 32: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 32

z13s Physical Planning

Page 33: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 33

z13s Physical Planning

Always  Refer  to  the  Installa9on  Manual  for  Physical  Planning  for  

details:  M/T  2965  –  GC28-­‐6953  

! Air cooled ! Single frame, Footprint size consistent with zBC12 ! Weight similar to zBC12 ! Universal AC & DC power, two 30 amp power plugs ! Single phase or 3 phase power options available ! Integrated Battery Feature ! Top or bottom exit I/O and Power ! Raised floor and non raised floor installations ! ASHRAE Class A3 (40OC and 85% relative humidity operating limits) ! Door locks: both doors (front/rear) will arrive with the lock installed

(4 keys total) ! Rack mounted 1U HMC & TKE

Page 34: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 34

HMC or TKE System Unit

The System unit and tray must be mounted in a customer rack in two adjacent 1U locations in the “ergonomic zone” between 21U and 26U. Three C13 power receptacles

are required, two for the System Unit and one for the Display and Keyboard.

HMC or TKE Display and Keyboard IBM 1U 18.5-inch Standard Console (1723-8BX)

Install between

21U & 26U

Customer Supplied Rack (Cannot configure or order using z Systems eConfig)

z13s & z13 HMC & TKE Rack Mounted

Page 35: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 35

Operating System Support for z13s and z13 GA2 Operating System Supported levels

z/OS ! z/OS V2.2 with PTFs ! z/OS V2.1 with PTFs (Exploitation) ! z/OS V1.13 with PTFs (Limited Exploitation).

Note: End of Support for z/OS V1.13 = September 2016 ! z/OS V1.12 with PTFs (Service support ended 9/30/2014).

Note: TSS Service Extension for z/OS V1.12 Defect Support: Offered (10/1/14 – 9/30/17) will be required for z13s & z13 GA2 compatibility at GA

z/VM ! z/VM 6.4 – GA 4Q2016 ! z/VM V6.3 with PTFs – Exploitation support ! z/VM V6.2 with PTFs – Compatibility plus Crypto Express5S support

z13s and z13 is the last generation supported by V6.2 (EoS 12/31/16) ! Note: z/VM 5.4 – NOT Compatible even though still in service until 12/31/2016

z/VSE ! z/VSE V6.1 with PTFs ! z/VSE V5.2 with PTFs – Compatibility + Crypto Express5S (up to 40/85 LPARs) ! z/VSE V5.1 with PTFs – Compatibility (End of service 6/30/2016)

z/TPF ! z/TPF V1.1 with PTFs – Compatibility Linux on z Systems ! SLES 11 SP3+ and SLES 12 SP1+

! Red Hat RHEL 6.6+ and RHEL 7.1+ ! Canonical Ubuntu 16.04 LTS – GA 2Q2016

KVM for IBM z Systems

! KVM for IBM z V1.1.1 – GA 3/2016 ! KVM for IBM z V1.1.0

Page 36: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 36

Availability Dates

Page 37: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 37

IBM z13s Availability Dates – Driver Level 27 !  March 10, 2016

–  Features and functions for the IBM z13s (Type number: 2965) –  IBM z13s Models N10, N20 –  z114 upgrades to z13s Models N10 and N20 –  z114 with zBX Model 002 upgrades to IBM z13s and zBX Model 004 standalone –  zBC12 upgrades to z13s Models N10 and N20 –  zBC12 with zBX Model 003 upgrades to IBM z13s and zBX Model 004 standalone –  Field installed features and conversions on IBM z13s (LIC upgrade) –  TKE 8.1 LIC (#0878)

!  June 10, 2016 –  TKE Rack Mount (#0097)

!  June 30, 2016 – MES features for Models N10, N20 –  z/VSE Network Appliance using the z Appliance Container Infrastructure (zACI)

!  September 26, 2016 –  Frame Roll MES upgrades IBM z13s N20 to IBM z13 N30

!  December 31, 2016 (might be earlier, depending on the feature) –  HMC Tower (#0095) –  HMC Rack Mount (#0096) –  TKE Tower (#0098)

IBM z13s

Page 38: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 38

IBM z13 GA2 Availability Dates – Driver Level 27 ! March 10, 2016

– New GA2 features and functions for the IBM z13 (Type number: 2964) – TKE 8.1 LIC (#0878)

! June 10, 2016 – TKE Rack Mount (#0097)

! June 30, 2016 – z/VSE Network Appliance using the z Appliance Container Infrastructure

(zACI) ! December 31, 2016 (might be earlier, depending on the feature)

– HMC Tower (#0095) – HMC Rack Mount (#0096) – TKE Tower (#0098)

IBM z13

Page 39: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 39

IBM z13s and z13 GA2 Key Dates – 2016

! February 16, 2016 – ITSO Redbooks – Draft Versions – New – IBM z13 and z13s Technical Introduction, SG24-8250-01 – Updated - IBM z13 Technical Guide, SG24-8251-01 – New - IBM z13s Technical Guide, SG24-8294 – IBM z13 Configuration Setup, SG24-8260 – IBM z Systems Connectivity Handbook, SG24-5444 – Updated – IBM z Systems Functional Matrix, REDP-5157-01

! February 16, 2016 – New ITSO Point Of Views publications: – Check the ITSO redbooks site for forthcoming information:

•  http://www.redbooks.ibm.com/

! March to June, 2016 – Worldwide ITSO z13 GA2 / z13s Workshops – http://www.redbooks.ibm.com/projects.nsf/WorkshopIndex/ (12/04 Amsterdam)

Page 40: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 40

Summary

Page 41: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 41

z13s Hardware Innovations Performance, Scalability, Capacity •  Growth in per-engine performance •  Significant total system capacity increase (up to 6 CPs - up to 20 IFLs) •  Substantial Increase in memory size - Balanced growth in conjunction with Performance/Capacity, specifically Linux use - Enables new uses, increased DB2 buffers, in memory Datamarts •  Increase in bandwidth and throughput of I/O providing improved access to stored data •  zIIP and IFL capacity improvement jump via SMT •  SIMD vector processing for analytics applications •  Extended support of zEDC; Flash Express Read/Write Cache for higher performance •  Shared Memory Communications – Direct (SMC-D) & SMC – Remote (SMC-R)

Resiliency, Availability, Serviceability •  Support of the new PCI-based coupling (ICA) •  Improved STP user interface, simplifying management and usability •  Subchannel set, easing implementation of multi-target PPRC, and GDPS Global Mirror •  IBM zAware support for z/OS and Linux

Infrastructure Efficiency •  New I/O Infrastructure and improved bandwidth •  zHPF extended distance II •  Fibre channel forward error correction codes •  Fabric I/O priority •  FICON dynamic routing •  Increase the number of devices per CHPID •  WWPN preservation for FCP

Security •  Cryptographic Coprocessor Subsystem - Improved performance - New crypto algorithms (i.e. Elliptic Curve, SHA3, Visa, FPE) - Future CCA updates required for the financial industry •  Cryptographic key support for Management, simplification and compliance •  Regional Crypto Enablement for Greater China Group (GCG)

Virtualization •  Increased virtualization capabilities of the physical resources - Increase number of LPAR partitions - Increased domain support for Crypto - Full memory support per LPAR - Multi vSwitch LAG support - Support for sharing RoCE adapters across LPAR partitions

Performance Scalability Capacity

Virtualization

Security

Resiliency Availability

Serviceability

Efficiency

Page 42: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 42

Statements of Directions

IBM's statements regarding its plans, directions, and intent are subject to change or withdrawal without notice at IBM's sole discretion. Information regarding

potential future products is intended to outline our general product direction and it should not be relied on in making a purchasing decision. The information

mentioned regarding potential future products is not a commitment, promise, or legal obligation to deliver any material, code, or functionality. Information about

potential future products may not be incorporated into any contract. The development, release, and timing of any future features or functionality

described for our products remain at our sole discretion.

Page 43: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 43

IBM z Systems Statements of Directions (SoD) !  Removal of an option for the way shared logical processors are managed under PR/

SM LPAR –  The IBM z13 and IBM z13s will be the last servers to support selection of the option to "Do not end

the timeslice if a partition enters a wait state" when the option to set a processor runtime value has been previously selected in the CPC RESET profile. The CPC RESET profile applies to all shared logical partitions on the machine, and is not selectable by the logical partition.

!  Removal of support for the HCA3-O fanout for 12x IFB InfiniBand coupling links for midrange z Systems

–  The IBM z13s will be the last mid-range z Systems server to support HCA3-O (#0171) 12x IFB InfiniBand coupling links. Mid-range z Systems enterprises should continue migrating to the Integrated Coupling Adapter (ICA-SR) (#0172) for high-speed short-range coupling connectivity.

!  Reduced support for the CPU Measurement Facility Problem-State counter set on IBM z Systems

–  The CPU Measurement Facility (CPUMF) provides four CPU counter sets on each server (basic, problem–state, crypto-activity, and extended). Counters in the CPU counter sets count CPU activities on a logical CPU basis, incrementing for specific activities by one for each CPU cycle when the CPU is in the operating state, and the counter set is active. The problem-state counter set consists of 6 counter values, one of which is the instruction count, which counts the total number of instructions executed when the CPU is in the problem state. IBM z13, IBM z13s, will be the last server generations to support 6 counters in the problem-state counter set. On future servers, the number of implemented counters in the problem-state counter set will be reduced to 1: the problem state instruction count.

Page 44: GSE z13s z13 GA2 - GSE Young Professionalsgsebelux.com/system/files/GSE z13s z13 GA2.pdf · China Group (GCG) only** Note: new functional items available on z13 GA2 and z13s System,

© 2016 IBM Corporation 44