groove-turn - kjv.dk · groove-turn tgfh 100-9 l1 a 150º w h 1b dmax tgfh 100,150 ... tgfh 100-9...

1
283 GROOVE-TURN TGFH 100-9 l1 A 150º W h1 B1 Dmax TGFH 100,150 TGFH...1.4/1.6 TGFH...K L3 Designation B1 W min W max A l1 L3 h1 D max Insert TGFH 52K-8 (1) 52.6 7.70 8.50 7.20 190.00 - 45.2 190.0 Y TAG 8 ETG 8-12* TGFH 53K-8 (1) 52.6 7.70 8.50 7.20 260.00 - 45.2 215.0 Y TAG 8 ETG 8-12* TGFH 52K-9 (1) 52.6 8.70 10.00 8.20 190.00 - 45.2 190.0 Y TAG 9 ETG 8-12* TGFH 53K-9 (1) 52.6 8.70 10.00 8.20 260.00 - 45.2 215.0 Y TAG 9 ETG 8-12* TGFHR/L 53K-12 (1) 52.6 11.70 12.70 10.00 260.00 - 45.2 215.0 Y TAG 12 ETG 8-12* TGFH 100-9 100.0 8.70 10.00 8.20 460.00 - 92.5 450.0 N TAG 9 ETG 8-12* TGFH 100-12 100.0 11.70 12.70 10.00 460.00 - 92.5 450.0 N TAG 12 ETG 8-12* TGFH 150-12 150.0 11.70 12.70 10.00 610.00 - 142.5 600.0 N TAG 12 ETG 8-12* • For user guide, see pages 340-351 (1) With coolant holes, the recommended coolant pressure is 10 bar min.; cooling tube SGCU 341 should be ordered separately * Optional, should be ordered separately (2) Thickness beyond the D.O.C. area is 2.50 mm (3) Thickness beyond the D.O.C. area is 1.60 mm For inserts, see pages: TAG N-A (402) • TAG N-C/W/M (399) • TAG N-J/JS/JT (400) • TAG N-LF (401) • TAG N-MF (400) • TAG N-UT (402) • TAG R/L-C (399) • TAG R/L-J/JS (401) • TAGB/TAGBA (284) For holders, see pages: C#-TBK-R/L (477) • HSK A-WH-TBK-R/L (482) • SGTBF (473) • SGTBK (473) • SGTBR/L (473) • SGTBU/SGTBN (472) • UBHCR/L (473) Coolant inlet SGCU-341 (should be ordered separately) Coolant outlet TGFH/R/L Blades with a Tangentially Oriented Pocket Carrying TANG-GRIP Single- Ended Inserts for Parting and Grooving l2 h h b A f T W h4 G 1/8"-28 typx2 l1 Right-hand shown Bar Max Designation h W b l2 A l1 Tmax-r f h4 TGBHR/L 25-8-JHP 25.0 8.00 25.0 42.0 7.00 150.00 25.00 21.5 12.0 ETG 8-12* PLG 1/8ISO1179 HW 5.0 TGBHR/L 32-8-JHP 32.0 8.00 32.0 42.0 7.00 170.00 25.00 28.5 12.0 ETG 8-12* PLG 1/8ISO1179 HW 5.0 • For user guide see pages 340-355 * Optional, should be ordered separately For inserts, see pages: TAG N-C/W/M (399) • TAGB/TAGBA (284) Flow Rate vs. Pressure Designation 70 Bar Flow Rate (liters/min) 100 Bar Flow Rate (liters/min) 140 Bar Flow Rate (liters/min) TGBHR/L-JHP 13-16 19-21 22-24 Insertion Side Extraction Side ETG 8-12 Extractor for 8 to 12.7 mm Inserts TGBHR/L-JHP Grooving and Turning SUMO-GRIP Tools with Channels for High Pressure Coolant

Upload: others

Post on 21-Jul-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GROOVE-TURN - kjv.dk · GROOVE-TURN TGFH 100-9 l1 A 150º W h 1B Dmax TGFH 100,150 ... TGFH 100-9 100.0 8.70 10.00 8.20 460.00 - 92.5 450.0 N TAG 9 ETG 8-12* TGFH 100-12 100.0 11.70

283

GR

OO

VE

-TU

RN

TGFH 100-9

l1

A150º

W

h1 B1Dmax

TGFH 100,150

TGFH...1.4/1.6

TGFH...K

L3

Designation B1 W min W max A l1 L3 h1 D max InsertTGFH 52K-8 (1) 52.6 7.70 8.50 7.20 190.00 - 45.2 190.0 Y TAG 8 ETG 8-12*TGFH 53K-8 (1) 52.6 7.70 8.50 7.20 260.00 - 45.2 215.0 Y TAG 8 ETG 8-12*TGFH 52K-9 (1) 52.6 8.70 10.00 8.20 190.00 - 45.2 190.0 Y TAG 9 ETG 8-12*TGFH 53K-9 (1) 52.6 8.70 10.00 8.20 260.00 - 45.2 215.0 Y TAG 9 ETG 8-12*TGFHR/L 53K-12 (1) 52.6 11.70 12.70 10.00 260.00 - 45.2 215.0 Y TAG 12 ETG 8-12*TGFH 100-9 100.0 8.70 10.00 8.20 460.00 - 92.5 450.0 N TAG 9 ETG 8-12*TGFH 100-12 100.0 11.70 12.70 10.00 460.00 - 92.5 450.0 N TAG 12 ETG 8-12*TGFH 150-12 150.0 11.70 12.70 10.00 610.00 - 142.5 600.0 N TAG 12 ETG 8-12*

• For user guide, see pages 340-351(1) With coolant holes, the recommended coolant pressure is 10 bar min.; cooling tube SGCU 341 should be ordered separately * Optional, should be ordered separately (2) Thickness beyond the D.O.C. area is 2.50 mm (3) Thickness beyond the D.O.C. area is 1.60 mmFor inserts, see pages: TAG N-A (402) • TAG N-C/W/M (399) • TAG N-J/JS/JT (400) • TAG N-LF (401) • TAG N-MF (400) • TAG N-UT (402) • TAG R/L-C (399) • TAG R/L-J/JS (401) • TAGB/TAGBA (284)For holders, see pages: C#-TBK-R/L (477) • HSK A-WH-TBK-R/L (482) • SGTBF (473) • SGTBK (473) • SGTBR/L (473) • SGTBU/SGTBN (472) • UBHCR/L (473)

Coolant inlet SGCU-341 (should be ordered separately) Coolant outlet

TGFH/R/LBlades with a Tangentially Oriented Pocket Carrying TANG-GRIP Single-Ended Inserts for Parting and Grooving

l2

h h

b

A

f TW

h4

G 1/8"-28 typx2l1

Right-hand shown

Bar Max

Designation h W b l2 A l1 Tmax-r f h4

TGBHR/L 25-8-JHP 25.0 8.00 25.0 42.0 7.00 150.00 25.00 21.5 12.0 ETG 8-12* PLG 1/8ISO1179 HW 5.0TGBHR/L 32-8-JHP 32.0 8.00 32.0 42.0 7.00 170.00 25.00 28.5 12.0 ETG 8-12* PLG 1/8ISO1179 HW 5.0

• For user guide see pages 340-355* Optional, should be ordered separately For inserts, see pages: TAG N-C/W/M (399) • TAGB/TAGBA (284)

Flow Rate vs. Pressure

Designation70 Bar

Flow Rate (liters/min)100 Bar

Flow Rate (liters/min)140 Bar

Flow Rate (liters/min)TGBHR/L-JHP 13-16 19-21 22-24

Insertion Side

Extraction Side

ETG 8-12 Extractor for 8 to 12.7 mm Inserts

TGBHR/L-JHPGrooving and Turning SUMO-GRIP Tools with Channels for High Pressure Coolant