gf piping systems worldwide at home

142
Global Installation Fittings and K-Factors Global Installation Fittings and K-Factors K-Factor Global

Upload: others

Post on 02-Apr-2022

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GF Piping Systems worldwide at home

Global Installation F

ittings and K-Factors

3-0000.706 (B-7/10) #1285 (7/10)©Copyright Georg Fischer Signet LLC.3401 Aerojet Avenue, El Monte, CA 91731-2882Tel (626) 571-2770, Fax (626) 573-2057Printed in U.S.A.

GF Piping Systems worldwide at homewww.gfsignet.com

Global Installation Fittingsand K-Factors

The technical data is not binding. They neither constitute expressly warranted characteristics nor guaranteed properties nor a guaranteed durability. They are subject to modification. Our General Terms of Sale apply. Adding Quality to People’s Lives

Our sales companies and representatives ensure local customer

support in over 100 countries.

K-Factor

GlobalArgentina / Southern South AmericaGeorg Fischer Central Plastics Sudamérica S.R.L.Buenos Aires, ArgentinaPhone +5411 4512 02 [email protected]

AustraliaGeorge Fischer Pty LtdRiverwood NSW 2210 AustraliaPhone +61(0)2 9502 8000 [email protected]

Austria Georg Fischer Rohrleitungssysteme GmbH3130 HerzogenburgPhone +43(0)2782 856 [email protected]

Belgium / LuxembourgGeorg Fischer NV/SA1070 Bruxelles/BrüsselPhone +32(0)2 556 40 [email protected]

BrazilGeorg Fischer Ltda04795-100 São PauloPhone +55(0)11 5525 [email protected]

CanadaGeorg Fischer Piping Systems LtdBrampton, ON L6T 4E3Phone +1(905)792 8005Fax +1(905)792 [email protected]

ChinaGeorg Fischer Piping Systems Ltd Shanghai Pudong, Shanghai 201319Phone +86(0)21 58 13 33 33 [email protected]

Denmark / IcelandGeorg Fischer A/S2630 TaastrupPhone +45 (0)70 22 19 [email protected]

FranceGeorg Fischer SAS95932 Roissy Charles de Gaulle CedexPhone +33(0)1 41 84 68 [email protected]

GermanyGeorg Fischer GmbH73095 Albershausen Phone +49(0)7161 [email protected]

IndiaGeorg Fischer Piping Systems Ltd400 076 MumbaiPhone +91 224007 [email protected]

ItalyGeorg Fischer S.p.A.20063 Cernusco S/N (MI)Phone +3902 921 [email protected]

NorwayGeorg Fischer AS1351 Rud Phone +47(0)67 18 29 [email protected]

PolandGeorg Fischer Sp. z o.o.05-090 Sekocin Nowy Phone +48(0)22 31 31 0 50 [email protected]

RomaniaGeorg Fischer Piping Systems Ltd020257 Bucharest - Sector 2Phone +40(0)21 230 53 [email protected]

RussiaGeorg Fischer Piping SystemsMoscow 125047Tel. +7 495 258 60 [email protected]

SingaporeGeorge Fischer Pte Ltd528 872 SingaporePhone +65(0)67 47 06 [email protected]

Spain / PortugalGeorg Fischer S.A.28046 MadridPhone +34(0)91 781 98 [email protected]

Sweden / FinlandGeorg Fischer AB117 43 StockholmPhone +46(0)8 506 775 00info.se.ps@georgfischer.comwww.georgfischer.sewww.georgfischer.fi

SwitzerlandGeorg Fischer Rohrleitungssysteme (Schweiz) AG8201 SchaffhausenPhone +41(0)52 631 30 [email protected]

TaiwanGeorg Fischer Piping SystemsSan Chung City, Taipei HsienPhone +886 2 8512 2822Fax +886 2 8512 2823www.georgfischer.tw

United Kingdom / IrelandGeorge Fischer Sales LimitedCoventry, CV2 2STPhone +44(0)2476 535 [email protected]

USA / CaribbeanGeorg Fischer LLCTustin, CA 92780-7258Phone +1(714) 731 88 00 Toll Free 800 854 40 [email protected]

International Georg Fischer Piping Systems (Switzerland) Ltd.8201 Schaffhausen/SwitzerlandPhone +41(0)52 631 30 03Fax +41(0)52 631 28 [email protected]

JapanGeorg Fischer Ltd556-0011 Osaka, Phone +81(0)6 6635 [email protected]

Korea Georg Fischer Piping SystemsGuro-3 dong, Guro-gu, Seoul, KoreaPhone +82(0)2 2081 1450Fax +82(0)2 2081 1453 [email protected]

MalaysiaGeorge Fischer (M) Sdn. Bhd.40460 Shah Alam, Selangor Darul EhsanPhone +60 (0)3 5122 [email protected]

Mexico / Northern Latin AmericaGeorg Fischer S.A. de C.V.Apodaca, Nuevo LeonCP66636 MexicoPhone +52 (81)1340 8586Fax +52 (81)1522 [email protected]

Middle EastGeorge Fischer Piping Systems Dubai, United Arab Emirates Phone +971 4 289 49 60 [email protected]

NetherlandsGeorg Fischer N.V.8161 PA EpePhone +31(0)578 678 222 [email protected]

Page 2: GF Piping Systems worldwide at home

K-Factor CD

Page 3: GF Piping Systems worldwide at home

3

How to Find your Installation Fitting

EUROPE - Fittings

PVC-U

PP

PE

PVDF

ABS

COOL-FIT

Metals

ASIA - Fittings

JIS

PVC-U / PVC-C

PP

PVDF

Fibreglass

ABS

Metals

Electrofusion

USA - Fittings

PVC-U / CPVC

PP

PVDF

Fiberglass

Metals

Electrofusion

K-Factors / Union End Table

Support

5

6 – 7

8 – 13

14 – 21

22 – 27

28 – 35

36 – 37

38 – 39

40 – 47

48 – 49

50 – 51

52 – 59

60 – 61

62 – 63

64 – 65

66 – 67

68 – 79

80 – 81

82 – 83

84 – 91

92 – 93

94 – 95

96 – 97

98 – 109

110 – 111

112 – 139

140 – 141

Table of Contents

Page 4: GF Piping Systems worldwide at home

4

Installation Fittings for Signet Sensors

GF Piping Systems Global Installation Fittings and K-Factor brochure has been developed for our customers around the world. The brochure will guide you in selecting the correct fitting to use with GF Signet sensors.

The new K-Factor Calculation Tool (provided on the included CD) offers customers an extremely easy, fast and convenient way to calculate K-Factors for GF Signet sensor and fitting combinations.

Along with ease of use, the new tool is capable of automatic database updating via the internet, ensuring that the user always has the most up-to-date information.

The Global Installation Fittings and K-Factor brochure has been separated into regions for ease of accessibility in selecting the proper fittings available within your region.

Each region provides an overview table outlining the various GF fittings. Fittings are available in metric, JIS or ASTM, and vary by region.

Added Value

Page 5: GF Piping Systems worldwide at home

5

2

1

3

4

5

Select yourRegion/Connection Standard

Select yourPipe Material

K-FactorReference

Note: The sensor length will be selected by the fitting.

PVC-U / PVC-C

PE

PVDF

ABS

METALS

EUR

OPE

ASI

AU

SA

How

to fi

nd y

our

inst

alla

tion

fitt

ing

Choose yourFitting

Find yourSensor

Page 6: GF Piping Systems worldwide at home

6

Material Fitting Joint Gasket Dimension Sensor Type Pressure Temperature Page

PVC

-U

Solvent cementing EPDM/FPM d20 - d63 Flow, pH max. 16 bar 0 °C - +60 °C 8

Hot gas back welding no gasket d75 - d630 Flow, pH

depends on quality of the welding

0 °C - +60 °C 8

Solvent cementing no gasket d75 - d315 Flow max. 10 bar 0 °C - +60 °C 10

Saddle/ Solvent cementing EPDM/FPM d75 - d225 Flow, pH max. 16 bar 0 °C - +60 °C 10

Alternative solution can be a PP saddle or wafer. Pipe size, pressure rating and chemical resistance need to be evaluated.

PP

-H

Socket fusion EPDM/FPM d20 - d63 Flow, pH max. 16 bar -10 °C - +95 °C 14

Butt fusion EPDM/FPM d20 - d63 Flow, pH max. 16 bar -10 °C - +95 °C 14

Hot gas back welding no gasket d75 - d630 Flow, pH

depends on quality of the welding

-10 °C - +95 °C 14

Screw-on saddle EPDM d75 - d315 Flow 5 - 8 bar 0 °C - +40 °C 16

Flange adapters EPDM/FPM d75 - d315 Flow max. 16 bar -10 °C - +95 °C 16

Screw-on saddle NBR d25 - d225 Other 10 - 16 bar -10 °C - +45 °C 18

Socket fusion no gasket d75 - d400 Other max. 16 bar -10 °C - +60 °C 20

PE

Hot gas back welding no gasket d75 - d630 Flow, pH

Depends on quality of the welding

-10 °C - +60 °C 24

Socket fusion no gasket d75 - d400 Other max. 16 bar -10 °C - +60 °C 24

via ELGEF saddle no gasket d63 - d400 Other max. 16 bar -10 °C - +60 °C 24

via ELGEF saddle no gasket d63 - d400 Other max. 12.5 bar -10 °C - +60 °C 24

Alternative solution can be a PP saddle or wafer. Pipe size, pressure rating and chemical resistance need to be evaluated.

Table of Contents

Europe Fittings

Page 7: GF Piping Systems worldwide at home

7

Material Fitting Joint Gasket Dimension Sensor Type Pressure Temperature Page

PVD

F

Socket fusion FPM d20 - d63 Flow, pH max. 16 bar -20 °C - +140 °C 28

Butt fusion FPM d20 - d63 Flow, pH max. 16 bar -20 °C - +140 °C 28

Hot gas back welding no gasket d75 - d630 Flow, pH

Depends on quality of the welding

-20 °C - +140 °C 30

Flange adapters FPM d75 - d225 Flow max. 16 bar -20 °C - +140 °C 30

Butt fusion no gasket d63 - d110 Other max. 16 bar -20 °C - +140 °C 32

Butt fusion no gasket d63 - d225 Other max. 16 bar -20 °C - +140 °C 32

Socket fusion no gasket d63 - d110 Other max. 16 bar -20 °C - +140 °C 34

AB

S

Solvent cementing no gasket d25 - d63 Flow, pH max. 10 bar -40 °C - +60 °C 36

Solvent cementing no gasket d75 - d225 Flow max. 10 bar -40 °C - +60 °C 36

CO

OL-

FIT Solvent

cementing no gasket d25 - d225 Flow max. 10 bar -40 °C - +40 °C 38

Solvent cementing no gasket d25 - d225 Pressure max. 10 bar -40 °C - +40 °C 38

Met

als

Welding no gasket d63 - d630 Flow max. 16 bar – 40

Welding NBR d40 - d800 Flow max. 16 bar – 40

Welding no gasket d20 - d32 Flow max. 16 bar – 40

Welding no gasket d40 - d315 Flow max. 16 bar – 40

Straping EPDM/NBR d60 - d355 Other max. 16 bar – 42

Clamping NBR d68 - d289 Other max. 16 bar – 44-46

EUR

OPE

Page 8: GF Piping Systems worldwide at home

8

PVC-U

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on page 139)

Type 314, PVC-U, weld o let, metric

Code No. d [mm] DN [mm] Sensor Type

721 314 000 75 - 180 65 - 150 Flow -X0, pH - XX

721 314 001 200 - 355 200 - 350 Flow -X1

721 314 002 400 - 630 350 - 600 Flow -X2

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 272X-XX• Sensor length depends on installation fitting

Type 310, PVC-U for Socket Systems metric

EPDM Code No.

FPM Code No.

d [mm]

DN [mm]

Sensor Type

721 310 006 721 310 036 20 15 Flow -X0, pH -XX

721 310 007 721 310 037 25 20 Flow -X0, pH -XX

721 310 008 721 310 038 32 25 Flow -X0, pH -XX

721 310 009 721 310 039 40 32 Flow -X0, pH -XX

721 310 010 721 310 040 50 40 Flow -X0, pH -XX

721 310 011 721 310 041 63 50 Flow -X0, pH -XX

Alternative solution can be a PP saddle or wafer. Pipe size, pressure rating and chemical resistance need to be evaluated.

Page 9: GF Piping Systems worldwide at home

9

Tee

Type 310, PVC-U for Socket Systems metric

d [mm]

PND [mm]

z [mm]

L[mm]

L1[mm]

H [mm]

20 16 43 48 128 90 76

25 16 51 53 144 100 78

32 16 58 58 160 110 81

40 16 72 58 168 110 85

50 16 83 63 188 120 89

63 16 100 68 212 130 95

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting

Weld o let

Type 314, PVC-U, weld o let, metric

d [mm] D [mm] L [mm]

75 - 180 37.5 68

200 - 355 37.5 102

400 - 630 37.5 178

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Please consult the instruction manual• For conventional hot gas back welding according to DVS 2207 part 3• Your maximum allowable pressure may be determined by the pressure rating of the pipe material, quality of weld and/or installed sensor• pH sensors can only be used up to 4 in. or DN100 pipe

PVC

-U

272X

515

2537

2536

2551

Page 10: GF Piping Systems worldwide at home

10

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX• Sensor length depends on installation fitting

• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX• Sensor length depends on installation fitting

Type 312, PVC-U, Glue-on Saddle, metric

Code No.d [mm]

DN [mm]

Sensor Type

721 312 012 75 65 Flow -X1

721 312 013 90 80 Flow -X1

721 312 014 110 100 Flow -X1

721 312 015 125 100 Flow -X1

721 312 016 140 125 Flow -X1

721 312 017 160 150 Flow -X1

721 312 019 200 200 Flow -X1

721 312 020 225 200 Flow -X2

721 312 021 250 250 Flow -X2

721 312 023 315 300 Flow -X2

PVC-U

Flow and pH

Type 312, PVC-U Clamp-on Saddle, metric

Code No.d [mm]

DN [mm]

Sensor Type

198 150 538 75 65 Flow -X0, pH-XX

198 150 539 90 80 Flow -X0, pH-XX

198 150 540 110 100 Flow -X0, pH-XX

198 150 543 160 150 Flow -X1

198 150 545 225 200 Flow -X1

Alternative solution can be a PP saddle or wafer. Pipe size, pressure rating and chemical resistance need to be evaluated.

Page 11: GF Piping Systems worldwide at home

11

Saddle

Type 312, PVC-U, Glue-on Saddle, metric

d [mm] PN D [mm] H [mm]

75 10 38 89

90 10 38 89

110 10 38 89

125 10 38 81

140 10 38 79

160 10 38 76

200 10 38 69

225 10 38 141

250 10 38 137

315 10 38 127

Type 312, PVC-U Clamp-on Saddle, metric

d [mm] PN H [mm] L [mm]

75 16 99 105

90 16 105 105

110 16 114 105

160 16 156 120

225 16 184 120

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Top saddle for solvent cement bonding• Seal: Lip seal of EPDM• pH sensors can only be used up to 4 in. or DN100 pipe

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Top saddle for solvent cement bonding

PVC

-U

272X

515

2537

2536

2551

Page 12: GF Piping Systems worldwide at home

12

Type 310, BSP PVC-U for Socket Fusion, BS inch

EPDM Code No.

FPM Code No.

d [in.]

d [mm]

DN [mm]

Sensor Type

721 310 306 721 310 336 1/2 20 15 Flow -X0, pH -XX

721 310 307 721 310 337 3/4 25 20 Flow -X0, pH -XX

721 310 308 721 310 338 1 32 25 Flow -X0, pH -XX

721 310 309 721 310 339 1¼ 40 32 Flow -X0, pH -XX

721 310 310 721 310 340 1½ 50 40 Flow -X0, pH -XX

721 310 311 721 310 341 2 63 50 Flow -X0, pH -XX

Type 312, BSP PVC-U, Clamp-on Saddle, BS inch

Code No.d [in.]

DN [mm]

Sensor Type

198 150 550 3 80 Flow -X0, pH -XX

198 150 551 4 100 Flow -X0, pH -XX

198 150 554 6 150 Flow -X1

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting• BSP - British Standard Pipe

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX• Sensor length depends on installation fitting• BSP - British Standard Pipe

PVC-U/BS Inch

Flow and pH

Alternative solution can be a PP saddle or wafer. Pipe size, pressure rating and chemical resistance need to be evaluated.

Page 13: GF Piping Systems worldwide at home

13

Tee

Saddle

Type 310, BSP PVC-U for Socket Fusion, BS inch

d [mm]

PND [mm]

z [mm]

L [mm]

L1 [mm]

H [mm]

20 15 43 48 131 90 76

25 15 51 53 147 100 78

32 15 58 58 164 110 81

40 15 72 58 171 110 85

50 15 83 63 188 120 89

63 15 100 68 211 130 95

Type 312, BSP PVC-U, Clamp-on Saddle, BS inch

d [mm]

PND [mm]

H [mm]

H1 [mm]

L [mm]

90 15 39 105 225 105

110 15 39 114 264 105

160 15 39 156 339 120

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• EPR (EPDM) Gasket

PVC

-U

272X

515

2537

2536

2551

Page 14: GF Piping Systems worldwide at home

14

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-X0, 3-2551-X0, 3-272X-XX• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on pg 139)

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on pg 139)

Type 318, PROGEF Standard, PP-H for Butt Fusion, metric

EPDM Code No.

FPM Code No.

d [mm]

DN [mm]

Sensor Type

727 318 006 727 318 036 20 15 Flow -X0, pH -XX

727 318 007 727 318 037 25 20 Flow -X0, pH -XX

727 318 008 727 318 038 32 25 Flow -X0, pH -XX

727 318 009 727 318 039 40 32 Flow -X0, pH -XX

727 318 010 727 318 040 50 40 Flow -X0, pH -XX

727 318 011 727 318 041 63 50 Flow -X0, pH -XX

PP

Flow and pH

Type 310, PROGEF Standard , PP-H for Socket Fusion, metric

EPDM Code No.

FPM Code No.

d [mm]

DN [mm]

Sensor Type

727 310 006 727 310 036 20 15 Flow -X0, pH -XX

727 310 007 727 310 037 25 20 Flow -X0, pH -XX

727 310 008 727 310 038 32 25 Flow -X0, pH -XX

727 310 009 727 310 039 40 32 Flow -X0, pH -XX

727 310 010 727 310 040 50 40 Flow -X0, pH -XX

727 310 011 727 310 041 63 50 Flow -X0, pH -XX

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 272X-XX• Sensor length depends on installation fitting

Type 314, PP-H, metric

Code No. DN [mm] Sensor Type

727 314 000 65 - 150 Flow -X0, pH -XX

727 314 001 200 - 350 Flow -X1

727 314 002 350 - 600 Flow -X2

Page 15: GF Piping Systems worldwide at home

15

Tee

Type 310, PROGEF Standard , PP-H for Socket Fusion, metric

d [mm]

PND [mm]

Z [mm]

L [mm]

L1 [mm]

H [mm]

20 10 48 50 128 90 76

25 10 58 55 142 100 78

32 10 65 60 156 110 81

40 10 79 60 160 110 85

50 10 91 65 176 120 89

63 10 105 70 194 130 95

• Threaded outlet 1¼ inch NPSM• Union end with butt fusion spigot PP-H

• Threaded outlet 1¼ inch NPSM• Union end with fusion socket PP-H

Type 318, PROGEF Standard, PP-H for Butt Fusion, metric

d [mm]

PND [mm]

Z [mm]

L [mm]

L1 [mm]

L2 [mm]

H [mm]

e

20 10 48 112 224 90 52 76 1.9

25 10 58 121 242 100 53 78 2.3

32 10 65 128 256 110 55 81 2.9

40 10 79 136 272 110 60 85 3.7

50 10 91 147 294 120 66 89 4.6

63 10 105 158 316 130 70 95 5.8

• Threaded outlet 1¼ inch NPSM• For conventional hot gas back welding according to DVS 2207 part 3• Please consult the instruction manual• Sensor length depends on installation fitting• Your maximum allowable pressure may be determined by the pressure rating of the pipe material, quality of weld and/or installed sensor• pH sensors can only be used up to 4 in. or DN100 pipe

Weld o letType 314, PP-H, metric

d [mm] D [mm] L [mm]

75 - 180 37.5 68

200 - 355 37.5 102

400 - 630 37.5 178

PP

272X

515

2537

2536

2551

Page 16: GF Piping Systems worldwide at home

16

PP

Flow

• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX• Sensor length depends on installation fitting

Type 312, PP-H, Screw-on, metric

Code No. d [mm] DN [mm] Sensor Type

727 312 072 75 65 Flow -X1

727 312 073 90 80 Flow -X1

727 312 074 110 100 Flow -X1

727 312 075 125 100 Flow -X1

727 312 076 140 125 Flow -X1

727 312 077 160 150 Flow -X1

727 312 078 180 150 Flow -X2

727 312 079 200 200 Flow -X2

727 312 080 225 200 Flow -X2

727 312 081 250 250 Flow -X2

727 312 082 280 250 Flow -X2

727 312 083 315 300 Flow -X2

• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX/X2-XX• Sensor length depends on installation fitting

Type 311, PROGEF Standard, PP-H, Wafer fitting, metric

EPDM Code No.

FPM Code No.

d [mm]

DN [mm]

Sensor Type

727 311 012 727 311 042 75 65 Flow -X1

727 311 013 727 311 043 90 80 Flow -X1

727 311 014 727 311 044 110 100 Flow -X1

727 311 015 727 311 045 125 100 Flow -X1

727 311 016 727 311 046 140 125 Flow -X1

727 311 017 727 311 047 160 150 Flow -X1

727 311 018 727 311 048 180 150 Flow -X1

727 311 019 727 311 049 200 200 Flow -X1

727 311 020 727 311 050 225 200 Flow -X1

727 311 021 727 311 051 250 250 Flow -X2

727 311 022 727 311 052 280 250 Flow -X2

727 311 023 727 311 053 315 300 Flow -X2

Page 17: GF Piping Systems worldwide at home

17

Saddle

Type 312, PP-H, Screw-on, metric

d [mm]

PND [mm]

L [mm]

L1 [mm]

H [mm]

H1 [mm]

75 8 34 78 62 172 88

90 8 34 86 69 186 87

110 8 34 98 79 206 86

125 8 34 101 85 212 78

140 6 34 114 104 227 75

160 6 34 114 114 243 72

180 6 34 168 134 348 144

200 6 34 168 132 357 142

225 5 34 174 146 375 136

250 5 34 179 159 397 131

280 5 34 179 167 426 127

315 5 34 248 202 450 120

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Top saddle with EPDM gasket• Stainless steel bolts and nuts• Saddle can be used with other pipe materials

Wafer Type 311, PROGEF Standard, PP-H, Wafer fitting, metric

d [mm]

PND [mm]

H[mm]

L[mm]

L1 [mm]

75 16 88 133 48 61

90 16 102 140 48 69

110 16 132 145 48 79

125 16 132 144 48 79

140 16 157 149 48 94

160 16 182 156 48 106

180 16 182 163 48 106

200 16 236 170 48 134

225 16 236 178 48 134

250 16 289 263 48 160

280 16 289 273 48 160

315 16 329 285 48 185

d

G

• Threaded outlet 1¼ NPSM• Suitable for backing flanges metric and inch• Suitable for SDR 11 - SDR 17.6• Delivered with profile FPM O-ring• Wafer can be used with other pipe materials• Sensor length depends on installation fitting

PP

515

2537

2536

2551

Page 18: GF Piping Systems worldwide at home

18

PP

Other Sensors

Poly16 Plus Clamp Saddle

Code No.d [mm]

Rp [in.]

Sensor Type

727 627 012 25 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 022 32 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 032 40 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 042 50 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 044 50 1¼ Flow 2552-X2

727 627 052 63 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 054 63 1¼ Flow 2552-X2

727 627 055 63 1½ pH/ORP 3719-2, Flow 2540-21-4, 2552-X4

727 627 062 75 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 064 75 1¼ Flow 2552-X2

727 627 065 75 1½ pH/ORP 3719-2, Flow 2540-21-4, 2552-X4

727 627 072 90 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 074 90 1¼ Flow 2552-X2

727 627 075 90 1½ pH/ORP 3719-2, Flow 2540-21-4, 2552-X4

727 627 082 110 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 084 110 1¼ Flow 2552-X2

727 627 085 110 1½ pH/ORP 3719-2, Flow 2540-21-4, 2552-X4

727 627 092 125 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 094 125 1¼ Flow 2552-X2

727 627 095 125 1½ pH/ORP 3719-2, Flow 2540-21-4, 2552-X4

727 627 102 140 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 104 140 1¼ Flow 2552-X2

727 627 105 140 1½ pH/ORP 3719-2, Flow 2540-21-4, 2552-X4

727 627 112 160 ¾ pH/ORP 2724-X-1, 2726-X-1, 2774-ISO, 2777-ISO, Conductivity 2839-1D, 2842-1D

727 627 114 160 1¼ Flow 2552-X2

727 627 115 160 1½ pH/ORP 3719-2 Flow 2540-21-4, 2552-X4

727 627 124 180 1¼ Flow 2552-X2

727 627 125 180 1½ pH/ORP 3719-2, Flow 2540-21-4, 2552-X4

727 627 145 225 1½ pH/ORP 3719-2 Flow 2540-21-4, 2552-X4

Page 19: GF Piping Systems worldwide at home

19

272X

3719

2552

2540

SaddlePoly16 Plus Clamp Saddle

d [mm]

PN d1 L L1 H H1

25 16 13 49 79 58 15

32 16 14 49 79 62 20

40 16 21 62 86 71 20

50 16 21 62 86 82 20

50 16 21 62 86 82 20

63 16 24 62 101 96 21

63 16 31 62 101 96 21

63 16 31 62 101 96 21

75 16 21 79 123 104 16

75 16 35 79 123 109 21

75 16 42 79 123 109 21

90 16 21 87 138 118 16

90 16 35 87 138 123 21

90 16 42 87 138 123 21

110 16 20 99 152 150 23

110 16 35 99 152 150 23

110 16 41 99 152 150 23

0.75 16 20 101 166 169 24

125 16 35 101 166 168 23

125 16 41 101 166 168 23

140 16 24 114 207 191 25

140 16 38 114 207 191 25

140 16 45 114 207 191 24

160 16 24 114 226 215 24

160 16 37 114 226 215 24

160 16 45 114 226 215 24

180 10 36 169 262 265 38

180 10 42 169 262 265 38

225 10 45 145 287 287 26

L1

d

d1

Rp

H

L

H1

• Stainless steel bolts• Saddle can be used with other pipe materials• Check H1 value vs. sensor length regarding minimum insertion depth.

PP

Page 20: GF Piping Systems worldwide at home

20

PP

Flow & Other Sensors

Adapter socket, PP-H, ANSI - NPT

Code No.d [mm]

DN [mm]

NPT [in.]

Sensor Type

727 914 357 75 - 800 65 - 800 3/4 2724-2726, 2774-2777, 2819-2842, 2350, 2450

727 914 358 75 - 800 65 - 800 1 2764-2767

727 914 359 75 - 800 65 - 800 1¼ 2552-X1

727 914 360 75 - 800 65 - 800 1½ 3719-11, 2540-1/-3, 2552-X3

727 914 361 75 - 800 65 - 800 2 3719-21

Adapter socket, PP-H, metric - ISO

Code No.DN [mm]

Rp[in.]

Sensor Type

727 914 357 65 - 800 3/4 2724-X1- 2726-X1, 2774-ISO, 2777-ISO, 2839-1D-2842-1D

727 914 359 65 - 800 1¼ 2552-X2

727 914 360 65 - 800 1½ 3719-12, 2540-2/-4, 2552-X4

Page 21: GF Piping Systems worldwide at home

21

Adapter socket, PP-H, ANSI - NPT

d [mm]

PND [mm]

L [mm]

L1 [mm]

s [mm]

75 - 800 10 25 51 23 36

75 - 800 10 32 54 23 46

75 - 800 10 40 56 23 55

75 - 800 10 50 60 23 65

75 - 800 10 63 62 23 80

Sockets

Adapter socket, PP-H, metric - ISO

d [mm]

PND [mm]

L [mm]

L1 [mm]

s [mm]

75 - 800 10 25 51 23 36

75 - 800 10 40 56 23 55

75 - 800 10 50 60 23 65

D

Rp

L1

• “d” is for pipe dimension • Connection via socket fusion• Check L1 value vs. sensor length regarding minimum insertion depth.

• “d” is for pipe dimension • Connection via socket fusion• Check H1 value vs. sensor length regarding minimum insertion depth.

PP

PP

272X

3719

2552

2540

D

L1

NPT

Page 22: GF Piping Systems worldwide at home

22

PE

Flow and pH

PE Tee Fitting

Code No. d [mm] DN [mm] Sensor Type

On Request 20 15 Flow -X0, pH -XX

On Request 15 20 Flow -X0, pH -XX

On Request 32 25 Flow -X0, pH -XX

On Request 40 32 Flow -X0, pH -XX

On Request 50 40 Flow -X0, pH -XX

On Request 63 50 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting

PE Tee Fitting

Code No. d [mm] DN [mm] Sensor Type

On Request 20 15 Flow -X0, pH -XX

On Request 15 20 Flow -X0, pH -XX

On Request 32 25 Flow -X0, pH -XX

On Request 40 32 Flow -X0, pH -XX

On Request 50 40 Flow -X0, pH -XX

On Request 63 50 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting

Alternative solution can be a PP saddle or wafer. Pipe size, pressure rating and chemical resistance need to be evaluated.

Page 23: GF Piping Systems worldwide at home

23

Tee

PE

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Union end with butt fusion spigot PE

PE Tee Fitting

d [mm]

PND [mm]

L [mm]

L1 [mm]

L2 [mm]

H [mm]

e

20 16 45 196 98 90 76 1.9

25 16 55 212 106 100 78 1.9

32 16 62 228 114 110 81 2.4

40 16 75 234 117 110 85 2.4

50 16 84 250 125 120 89 3.0

63 16 101 266 133 130 95 3.0

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Union end with butt fusion spigot PE

PE Tee Fitting

d [mm]

PND [mm]

L [mm]

L1 [mm]

L2 [mm]

H [mm]

e

20 16 45 196 98 90 76 1.9

25 16 55 212 106 100 78 1.9

32 16 62 228 114 110 81 2.4

40 16 75 234 117 110 85 2.4

50 16 84 250 125 120 89 3.0

63 16 101 266 133 130 95 3.0

272X

515

2537

2536

2551

Page 24: GF Piping Systems worldwide at home

24

PE

Flow & Other Sensors

Adapter Sockets, PE100, metric - ISO

Code No. d [mm] Sensor Type

753 910 267 75 - 800 272X, 277X-ISO, 2839-1D - 2842-1D

753 910 269 75 - 800 2552-X2

753 910 270 75 - 800 3719-12, 2540-2/-4, 2552-X4

Transition adapter PE/brass (MS58) ISO female thread, metric

Code No. d [mm] Rp [in.] Sensor Type

720 920 231 63 1.25 2552-X2

720 920 241 63 1.50 3719, 2540, 2552-X4

PE adapter ISO female thread, metric

Code No. d [mm] Rp [in.] Sensor Type

173 281 925 63 1.50 3719, 2540, 2552-X4

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Type 314, PE wedolet, metric and inch

Code No. d [mm] DN [mm] Sensor Type

753 314 000 75 - 180 65 - 150 Flow -X0, pH -XX

753 314 001 200 - 355 200 - 350 Flow -X1

753 314 002 400 - 630 350 - 600 Flow -X2

Page 25: GF Piping Systems worldwide at home

25

2537

2551

272X

3719

2552

Socket

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Connection via socket fusion• Small “d” is for pipe diameter

Adapter Sockets, PE100, metric - ISO

d [mm]

PNRp [in.]

D[mm]

L [mm]

L1[mm]

s[mm]

75 - 800 10 0.75 25 51 23 36

75 - 800 10 1.25 40 56 23 55

75 - 800 10 1.50 50 60 23 65

D

• 16 bar water• For electrofusion saddle (193 131 XXX and 193 135 159)

Transition adapter PE/brass (MS58) ISO female thread, metric

d [mm] PN L [mm] z

63 16 89 47

63 16 89 47

PE adapter ISO female thread, metric

d [mm] PN L [mm]

63 12.5 54

• Reinforcing ring stainless (A2)• For electrofusion saddle (193 131 XXX and 193 135 159)

Weld o let

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• For conventional hot gas back welding according to DVS 2207 part 3• Your maximum allowable pressure may be determined by the pressure rating of the pipe material, quality of weld and/or installed sensor

Type 314, PE wedolet, metric and inch

d [mm] D [mm] L [mm]

75 - 180 37 68

200 - 355 37 102

400 - 630 37 178

PE

Page 26: GF Piping Systems worldwide at home

26

PE

Other Sensors

ELGEF Plus, Electrofusion Saddle, PE100, SDR 11

Code No. d [mm]

193 131 037 63

193 131 047 75

193 131 057 90

193 131 067 110

193 131 077 125

193 131 087 140

193 131 097 160

193 131 107 180

193 131 117 200

193 131 127 225

193 131 137 250

193 131 147 280

193 131 157 315-400

ELGEF Plus Branch Fitting

Code No. d [mm]

193 135 159 500 - 630

Page 27: GF Piping Systems worldwide at home

27

272X

3719

2552

2540

Saddle

ELGEF Plus, Electrofusion Saddle, PE100, SDR 11

d [mm] d1 L [mm]

63 63 165

75 63 165

90 63 165

110 63 165

125 63 165

140 63 165

160 63 165

180 63 165

200 63 165

225 63 165

250 63 165

280 63 165

315-400 63 165

• Connection with transition adapter PE/Brass or PE adapter

ELGEF Plus Branch Fitting

d [mm]

d1 [mm]

H [mm]

L [mm]

L1 [mm]

B [mm]

d2 [mm]

500 - 630 90 102 260 82 263 65

• Can be used with reduction d90 - d63 (753 908 906)• Connection via socket fusion with transition adapter PE/brass or PE adapter

PE

Page 28: GF Piping Systems worldwide at home

28

PVDF

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on pg 139)

Type 310, SYGEF Standard, PVDF, Socket Fusion, metric

FPM Code No.d [mm]

DN [mm]

Sensor Type

735 310 036 20 15 Flow -X0, pH -XX

735 310 037 25 20 Flow -X0, pH -XX

735 310 038 32 25 Flow -X0, pH -XX

735 310 039 40 32 Flow -X0, pH -XX

735 310 040 50 40 Flow -X0, pH -XX

735 310 041 63 50 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on pg 139)

Type 318, SYGEF Standard, PDVF for Butt Fusion, metric

Code No. d [mm] DN [mm] Sensor Type

735 318 036 20 15 Flow -X0, pH -XX

735 318 037 25 20 Flow -X0, pH -XX

735 318 038 32 25 Flow -X0, pH -XX

735 318 039 40 32 Flow -X0, pH -XX

735 318 040 50 40 Flow -X0, pH -XX

735 318 041 63 50 Flow -X0, pH -XX

Page 29: GF Piping Systems worldwide at home

29

• Socket fusion equipment is required to install PVDF union tees• FPM O-rings• Sensor length depends on installation fitting

Type 310, SYGEF Standard, PVDF, Socket Fusion, metric

d [mm]

PND [mm]

Z [mm]

L [mm]

L1 [mm]

H [mm]

20 16 45 50 128 90 76

25 16 55 55 142 100 78

32 16 62 60 156 110 81

40 16 75 60 160 110 85

50 16 84 65 176 120 89

63 16 101 70 194 130 95

Tee

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Union end with butt fusion spigot PVDF

Type 318, SYGEF Standard, PDVF for Butt Fusion, metric

d [mm]

PND [mm]

L [mm]

L1 [mm]

L2 [mm]

H [mm]

e

20 16 45 196 90 37 76 1.9

25 16 55 212 100 37 78 1.9

32 16 62 228 110 40 81 2.4

40 16 75 234 110 40 85 2.4

50 16 84 250 120 43 89 3.0

63 16 101 266 130 43 95 3.0

PVD

F

272X

515

2537

2536

2551

Page 30: GF Piping Systems worldwide at home

30

PVDF

Flow and pH

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX• Sensor length depends on installation fitting

Type 314, SYGEF Standard, PVDF, metric

Code No. d [mm] DN [mm] Sensor Type

735 314 000 75 - 180 65 - 150 Flow -X0, pH -XX

735 314 001 200 - 355 200 - 350 Flow -X1

735 314 002 400 - 630 350 - 600 Flow -X2

• For use with P51530-X1, 3-2536-X1, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX• Sensor length depends on installation fitting

Type 311, SYGEF Standard, PVDF, metric

FPM Code No.d [mm]

DN [mm]

Sensor Type

735 311 042 75 65 Flow -X1

735 311 043 90 80 Flow -X1

735 311 044 110 100 Flow -X1

735 311 045 125 100 Flow -X1

735 311 046 140 125 Flow -X1

735 311 047 160 150 Flow -X1

735 310 049 200 200 Flow -X1

735 311 050 225 200 Flow -X1

Page 31: GF Piping Systems worldwide at home

31

Weld o let

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Please consult the instruction manual• Installation only be trained and certified welder• For conventional hot gas back welding according to DVS 2207 part 3• Your maximum allowable pressure may be determined by the pressure rating of the pipe material, quality of weld and/or installed sensor• pH sensors can only be used up to 4 in. or DN100 pipe

Type 314, SYGEF Standard, PVDF, metric

d [mm] D [mm] L [mm]

75 - 180 37.5 68

200 - 355 37.5 102

400 - 630 37.5 178

Wafer

Type 311, SYGEF Standard, PVDF, metric

d [mm]

PNH [mm]

D [mm]

L [mm]

L1 [mm]

75 10/16 135 88 48 61

90 10/16 141 102 48 69

110 10/16 148 132 48 79

125 10/16 147 132 48 79

140 10/16 153 157 48 94

160 10/16 161 482 48 106

200 10/16 175 236 48 134

225 10/16 185 236 48 134

d

G

• Threaded outlet 1¼ inch NPSM• Suitable for backing flanges metric and inch• Delevered with profile O-ring• Wafer can be used with other pipe materials• Sensor length depends on installation fitting

PVD

F

272X

515

2537

2536

2551

Page 32: GF Piping Systems worldwide at home

32

PVDF

Other Sensors

SYGEF Plus, PVDF Installation Fitting, PN 16

Code No.d [mm]

DN [mm]

735 918 811 63 50

735 918 812 75 65

735 918 813 90 80

735 918 814 110 100

SYGEF Plus, PVDF Installation Fitting, PN 16

Code No.d [mm]

DN [mm]

735 918 611 63 50

735 918 612 75 65

735 918 613 90 80

735 918 614 110 100

735 918 615 125 100

735 918 616 140 125

735 918 617 160 150

735 918 619 200 150

735 918 620 225 200

SYGEF Plus, PVDF Installation Fitting, PN 10

Code No.d [mm]

DN [mm]

735 918 565 125 100

735 918 566 140 125

735 918 567 160 150

735 918 569 200 200

735 918 570 225 200

Page 33: GF Piping Systems worldwide at home

33

272X

3719

2552

2540• For all 1/4 to 3/4 inch threaded sensors

SYGEF Plus, PVDF Installation Fitting, PN 16

d [mm]

PND [mm]

H [mm]

L1[mm]

e [mm]

63 16 85 89 25 3.0

75 16 96 101 25 3.6

90 16 110 116 25 4.3

110 16 127 136 25 5.3

Sockets

SYGEF Plus, PVDF Installation Fitting, PN 16

d [mm]

PND [mm]

H[mm]

L [mm]

e[mm]

63 16 106 97 100 3.0

75 16 115 108 90 3.6

90 16 128 121 90 4.3

110 16 145 139 90 5.3

125 16 162 157 100 6.0

140 16 176 171 110 6.7

160 16 194 190 110 7.7

200 16 231 228 110 9.6

225 16 254 251 110 10.8

SYGEF Plus, PVDF Installation Fitting, PN 10

d [mm]

PND [mm]

H[mm]

L [mm]

e [mm]

125 10 162 157 100 3.9

140 10 176 171 110 4.4

160 10 194 190 110 4.9

200 10 231 228 110 6.2

225 10 254 251 110 7.0

• For all 1/8 to 3/4 inch threaded sensors

• For all 1/8 to 3/4 inch threaded sensors

PVD

F

Page 34: GF Piping Systems worldwide at home

34

PVDF

Other Sensors

SYGEF Standard, PVDF, ANSI - NPT female thread

Code No.d [mm]

DN[mm]

NPT [in.]

Sensor Type

735 915 287 75 - 315 65 -300 3/4 272X, 277X, 2819-2842, 2350, 2450

735 915 288 75 - 315 65 -300 1 276X

735 915 289 75 - 315 65 -300 1¼ 2552-X1

735 915 290 75 - 315 65 -300 1½ 3719-11, 2540-1/-3, 2552-X3

SYGEF Standard, PVDF for ISO female thread

Code No.d [mm]

DN[mm]

Rp [in.]

Sensor Type

735 910 287 75 - 315 65 -300 3/4 272X, 277X-ISO, 2839-1D-2842-1D

735 910 289 75 - 315 65 -300 1¼ 2552-X2

735 910 290 75 - 315 65 -300 1½ 3719-12, 2540-2/-4, 2552-X4

• Check L1 value vs. sensor length regarding minimum insertion depth

• Check L1 value vs. sensor length regarding minimum insertion depth

Page 35: GF Piping Systems worldwide at home

35

272X

3719

2552

2540

SYGEF Standard, PVDF, ANSI - NPT female thread

PNNPT [in.]

D [mm]

L [mm]

L1[mm]

s[mm]

e [mm]

10 3/4 25 63 40 36 1.9

10 1 32 71 44 46 2.4

10 1¼ 40 79 49 55 2.4

10 1½ 50 84 55 60 3.0

Sockets

SYGEF Standard, PVDF for ISO female thread

PND [mm]

Rp [in.]

L [mm]

L1[mm]

s[mm]

e [mm]

10 25 3/4 63 40 36 1.9

10 40 1¼ 79 49 55 2.4

10 50 1½ 84 55 60 3.0

D

L1

NP

T

• Connection via socket fusion• Small “d” is for pipe dimension

• Connection via socket fusion• Small “d” is for pipe dimension

PVD

F

DRp

L1

Page 36: GF Piping Systems worldwide at home

36

ABS

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting

Type 310, ABS, metric

Code No.d [mm]

DN [mm]

Sensor Type

729 310 007 25 20 Flow -X0, pH -XX

729 310 008 32 25 Flow -X0, pH -XX

729 310 009 40 32 Flow -X0, pH -XX

729 310 010 50 40 Flow -X0, pH -XX

729 310 011 63 50 Flow -X0, pH -XX

• For use with P51530-X1, 3-2536-X1, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX• Sensor length depends on installation fitting

Type 312, ABS Glue-on saddle, metric

Code No.d [mm]

DN [mm]

Sensor Type

729 312 012 75 65 Flow -X1

729 312 013 90 80 Flow -X1

729 312 014 110 100 Flow -X1

729 312 016 140 125 Flow -X1

729 312 017 160 150 Flow -X1

729 312 019 200 200 Flow -X1

729 312 020 225 200 Flow -X1

Page 37: GF Piping Systems worldwide at home

37

Saddle

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• With solvent cement socket metric

Type 310, ABS, metric

d [mm]

PND [mm]

L[mm]

H[mm]

z[mm]

closest [inch]

25 10 35 100 78 32 0.75

32 10 44 110 81 33 1.00

40 10 51 110 85 29 1.25

50 10 63 120 89 29 1.50

63 10 78 130 95 28 2.00

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Top saddle for solvent cement bonding

Type 312, ABS Glue-on saddle, metric

d [mm]

PND [mm]

H[mm]

closest [inch]

75 10 38 91 2.50

90 10 38 91 3.00

110 10 38 91 4.00

140 10 38 81 5.00

160 10 38 77 6.00

200 10 38 71 8.00

225 10 38 67 8.00

Tee

AB

S

272X

515

2537

2536

2551

Page 38: GF Piping Systems worldwide at home

38

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX

Type 310, CoolFit, pre-insulated, metric

Code No.d [mm]

DN [mm]

Required nipple Sensor Type

738 310 107 25 20 738 901 107 Flow -X0, pH -XX

738 310 108 32 25 738 901 108 Flow -X0, pH -XX

738 310 109 40 32 738 901 109 Flow -X0, pH -XX

738 310 110 50 40 738 901 110 Flow -X0, pH -XX

738 310 111 63 50 738 901 111 Flow -X0, pH -XX

738 310 112 * 75 65 738 901 112 Flow -X1

738 310 113 * 90 80 738 901 113 Flow -X1

738 310 114 * 110 100 738 901 114 Flow -X1

738 310 116 * 140 125 738 901 116 Flow -X1

738 310 117 * 160 150 738 901 117 Flow -X1

738 310 119 * 200 200 738 901 119 Flow -X1

738 310 120 * 225 200 738 901 120 Flow -X1

• For use with all pressure sensors

Type 313, CoolFit, pre-insulated, metric

Code No.d [mm]

DN [mm]

Required nipple

738 313 107 25 20 738 901 107

738 313 108 32 25 738 901 108

738 313 109 40 32 738 901 109

738 313 110 50 40 738 901 110

738 313 111 63 50 738 901 111

738 313 112 * 75 65 738 901 112

738 313 113 * 90 80 738 901 113

738 313 114 * 110 100 738 901 114

738 313 116 * 140 125 738 901 116

738 313 117 * 160 150 738 901 117

738 313 119 * 200 200 738 901 119

738 313 120 * 225 200 738 901 120

ABS COOL-FIT

Flow, pH and Other Sensors

Page 39: GF Piping Systems worldwide at home

39

• Threaded outlet 1¼ NPSM• Insulation made from PUR• Outer jacket impact resistant. Color black

Type 310, CoolFit, pre-insulated, metric

d [mm]

PND [mm]

L [mm]

H [mm]

z [mm]

closest [inch]

25 10 90 220 78 110 ¾

32 10 90 220 81 110 1.00

40 10 110 220 85 110 1.00

50 10 110 220 89 110 1½

63 10 125 220 95 110 2.00

* 75 10 140 220 161 110 2½

* 90 10 160 220 171 110 3.00

* 110 10 180 220 181 110 4.00

* 140 10 225 220 193 110 5.00

* 160 10 250 220 202 110 6.00

* 200 10 280 250 211 125 8.00

* 225 10 315 280 225 140 8.00

Tee

• With ½ inch Rp threaded branch for sensors (i.e. pressure)• Insulation made from PUR• Outer jacket impact resistant. Color black

Type 313, CoolFit, pre-insulated, metric

d [mm]

PND [mm]

L [mm]

H [mm]

z [mm]

closest [inch]

25 10 90 160 100 80 ¾

32 10 90 160 100 80 1.00

40 10 110 180 100 90 1¼

50 10 110 180 100 90 1½

63 10 125 200 100 100 2.00

* 75 10 140 220 101 110 2½

* 90 10 160 220 109 110 3.00

* 110 10 180 220 119 110 4.00

* 140 10 225 220 134 110 5.00

* 160 10 250 220 145 110 6.00

* 200 10 280 250 165 125 8.00

* 225 10 315 280 178 140 9.00

*

*

CO

OL-

FIT

272X

515

2537

2536

2551

Page 40: GF Piping Systems worldwide at home

40

Metals

Flow and pH

Type 314, Stainless Steel, metric

Code No. d [mm] Sensor Type

724 314 000 63 - 180 Flow -X0/ pH -XX

724 314 001 200 - 355 Flow -X1

724 314 002 400 - 630 Flow -X2

• For use with 515, 8510, 2536, 8512, 2537, 2551, 272X• Threaded outlet 1¼ NPSM

• For use with P525-1 and P525-1S only

SS Weld-On Fittings (1.4401)

Code No. DN [mm] Inch

198 150 346 40 - 800 1.5 - 30

• For use with P525-2 and P525-2S

Metalex Socket Weld Mini-Tap (1.4401)

Code DN [mm] Size [in.] Sensor Type

198 840 501 15 0.50 P525-1, -1S

198 840 502 20 0.75 P525-1, -1S

198 840 503 25 1.00 P525-1, -1S

Page 41: GF Piping Systems worldwide at home

41

525

515

2537

2536

2551

272X

Weld-on

Type 314, Stainless Steel, metric

d [mm] D [mm] D [mm] L [mm]

63 - 180 75 - 180 37 68

200 - 355 200 - 355 37 102

400 - 630 400 - 630 37 178

75D

DN

H

61

49

90

40

SS Weld-On Fittings (1.4401)

Inch DN [mm]

1.5 - 30 40-800

Weld-on mini tap

• For use with SS pipei.d.

H

W

L

Metalex Socket Weld Mini-Tap (1.4401)D [mm]

H [mm]

L [in.]

W [in.]

H [in.]

i.d. [in.]

21.8 8.4 2.0 2.4 3.0 0.85

27.2 12.7 2.0 2.4 3.0 1.06

33.9 12.7 2.0 2.4 3.0 1.325

Met

als

Page 42: GF Piping Systems worldwide at home

42

• Ready to install, studs and nuts in one package• Do not use these fittings for PE pipes

Multi/Saddle Plus Spatula for use with Iron Multi/Saddle Plus 201

Code No. Description

709 613 904 Spatula for saddle outlet 1¼ inch

709 613 905 Spatula for saddle outlet 1½ inch / d40 + d50

• For use with 3-2552-2X/-3X, 3-2540-XX, 3-3719-11 Wet-Tap assembly with the 3-275X-WTX Wet-Tap electrode• Do not use these fittings for PE pipes• 1½ and 2 inch saddles must be applied for pipes DN80 or larger

• Do not use these fittings for PE pipes

Iron Multi/Saddle Plus 201

EPDM Code NBR Code Inch PN Water

PNGas Sensor Type

709 613 736 709 613 836 1.25 16.0 5.0 2552-2

709 613 738 709 613 838 1.50 16.0 5.0 2552-3, 2540-XX, 3719-11

Multi/Saddle Straps for use with Iron Multi/Saddle Plus 201

Code No. Strap Range [in.] DN min [mm]

DN max [mm]

709 613 930 2.375 3.25 60 80

709 613 932 2.75 3.625 70 90

709 613 934 3.625 4.375 90 110

709 613 936 4.375 5.25 110 130

709 613 938 5.25 6.00 130 150

709 613 940 5.75 6.625 145 165

709 613 942 6.375 7.25 160 180

709 613 944 7.00 7.75 175 195

709 613 946 7.625 8.375 190 210

709 613 948 8.25 9.00 205 225

709 613 950 8.75 9.625 220 240

709 613 952 9.375 10.25 235 255

709 613 954 10.00 10.75 250 270

709 613 956 10.75 11.625 270 290

709 613 958 11.375 12.25 285 305

709 613 960 12.00 12.75 300 320

709 613 962 12.625 13.375 315 335

709 613 964 13.375 14.25 335 355

Metals

Flow and Other Sensors

Page 43: GF Piping Systems worldwide at home

43

3719

2552

2540

Multi/Saddle

MU

LTI/

SAD

DLE

Hot Tap Adaptor Multi/Saddle Plus 201

Code No. Inch

709 613 638 1½

Met

als

Page 44: GF Piping Systems worldwide at home

44

Multi/Clamp Saddle Studs threaded outlet 3/4 inch

Code No. Range [mm] PN Water Sensor Type

724 201 062 68 - 78 16 2350, 2450, 272X, 276X, 277X

724 201 074 88 - 110 16 2350, 2450, 272X, 276X, 277X

724 201 098 108 - 134 16 2350, 2450, 272X, 276X, 277X

724 201 134 133 - 155 16 2350, 2450, 272X, 276X, 277X

724 201 170 159 - 181 16 2350, 2450, 272X, 276X, 277X

724 201 194 168 - 190 16 2350, 2450, 272X, 276X, 277X

724 201 206 190 - 212 16 2350, 2450, 272X, 276X, 277X

724 201 218 216 - 238 16 2350, 2450, 272X, 276X, 277X

724 201 230 238 - 260 16 2350, 2450, 272X, 276X, 277X

724 201 254 267 - 289 16 2350, 2450, 272X, 276X, 277X

Metals

Flow and Other Sensors

Multi/Clamp Saddle Studs threaded outlet 1¼ inch

Code No. Range [mm] PN Water Sensor Type

724 201 076 88 - 110 16 2552

724 201 100 108 - 134 16 2552

724 201 136 133 - 155 16 2552

724 201 172 159 - 181 16 2552

724 201 196 168 - 190 16 2552

724 201 208 190 - 212 16 2552

724 201 220 216 - 238 16 2552

724 201 232 238 - 260 16 2552

724 201 256 267 - 289 16 2552

Page 45: GF Piping Systems worldwide at home

45

3719

2552

2540

Multi/Saddle

• Saddle with threaded outlet• The rubber gasket is available in NBR (EPDM on request)• Lower shell half is without gasket (available on request)

Multi/Clamp Saddle Studs threaded outlet 3/4 inch

Range [mm] PN Water

68 - 78 16

88 - 110 16

108 - 134 16

133 - 155 16

159 - 181 16

168 - 190 16

190 - 212 16

216 - 238 16

238 - 260 16

267 - 289 16

Multi/Clamp Saddle Studs threaded outlet 1¼ inch

Range [mm] PN Water

88 - 110 16

108 - 134 16

133 - 155 16

159 - 181 16

168 - 190 16

190 - 212 16

216 - 238 16

238 - 260 16

267 - 289 16

• Saddle with threaded outlet• The rubber gasket is available in NBR (EPDM on request)• Lower shell half is without gasket (available on request)

Met

als

Page 46: GF Piping Systems worldwide at home

46

Metals

Flow and Other Sensors

Multi/Clamp Saddle Studs threaded outlet 1½ inch

Code No. Range [mm] PN Water Sensor Type

724 201 101 108 - 134 16 2552, 2540, 3719

724 201 137 133 - 155 16 2552, 2540, 3719

724 201 173 159 - 181 16 2552, 2540, 3719

724 201 197 168 - 190 16 2552, 2540, 3719

724 201 209 190 - 212 16 2552, 2540, 3719

724 201 221 216 - 238 16 2552, 2540, 3719

724 201 233 238 - 260 16 2552, 2540, 3719

724 201 257 267 - 289 16 2552, 2540, 3719

Multi/Clamp Saddle Studs threaded outlet 2 inch

Code No. Range [mm] PN Water Sensor Type

724 201 102 108 - 134 16 3719

724 201 138 133 - 155 16 3719

724 201 174 159 - 181 16 3719

724 201 198 168 - 190 16 3719

724 201 210 190 - 212 16 3719

724 201 222 216 - 238 16 3719

724 201 234 238 - 260 16 3719

724 201 258 267 - 289 16 3719

Page 47: GF Piping Systems worldwide at home

47

3719

2552

2540

Multi/Saddle

Multi/Clamp Saddle Studs threaded outlet 1½ inch

Range [mm] PN Water

108 - 134 16

133 - 155 16

159 - 181 16

168 - 190 16

190 - 212 16

216 - 238 16

238 - 260 16

267 - 289 16

• Saddle with threaded outlet• The rubber gasket is available in NBR (EPDM on request)• Lower shell half is without gasket (available on request)

Multi/Clamp Saddle Studs threaded outlet 2 inch

Range [mm] PN Water

108 - 134 16

133 - 155 16

159 - 181 16

168 - 190 16

190 - 212 16

216 - 238 16

238 - 260 16

267 - 289 16

• Saddle with threaded outlet• The rubber gasket is available in NBR (EPDM on request)• Lower shell half is without gasket (available on request)

Met

als

Page 48: GF Piping Systems worldwide at home

48

Table of Contents

Asia Fittings

Material Fitting Joint Gasket Dimension Sensor Type Pressure Temperature Page

JIS

Socket fusion EPDM/FPM d22 - d60 Flow, pH – – 50

Flange adapters – D76-D216 Flow, pH – – 50

PVC

-U

Saddle/ Solvent cementing

EPDM/FPM d75 - d225 Flow, pH max. 16 bar 0 °C - +60 °C 52

Solvent Cementing FPM 0.50 - 2.0 in. Flow, pH max. 16 bar 0 °C – +60 °C 52

Solvent Cementing no gasket 0.50 - 2.0 in. Flow, pH max. 13.8 bar 0 °C – +60 °C 54

Hot gas back welding no gasket 0.50 - 2.0 in. Flow, pH max. 12.6 bar 0 °C – +60 °C 54

Clamp-on saddle EPDM 2.0 - 8.0 in. Flow, pH max. 12.6 bar 0 °C – +60 °C 56

Glue-on saddle no gasket 10 - 12 in. Flow max. 16 bar 0 °C – +60 °C 56

PVC

-C

Solvent Cementing no gasket 0.50 - 2.0 in. Flow, pH max. 13.8 bar 0 °C – +100 °C 58

Solvent Cementing no gasket 0.50 - 2.0 in. Flow, pH max. 13.8 bar 0 °C – +100 °C 58

PP

Socket Fusion EPDM/FPM d20 - d63 Flow, pH max. 16 bar -10 °C – +95 °C 60

Flange adapters EPDM/FPM d75 - d315 Flow max. 16 bar -10 °C – +95 °C 60

PVD

F

Flange adapters FPM d75 - d225 Flow max. 16 bar -20 °C – +140 °C 62

Socket fusion FPM d20 - d63 Flow, pH max. 16 bar -20 °C – +140 °C 62

Page 49: GF Piping Systems worldwide at home

49

ASI

A

Material Fitting Joint Gasket Dimension Sensor Type Pressure Temperature Page

Fibr

egla

ssSolvent cementing PVDF insert 1.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C - +100 °C 64

Solvent cementing

PVDF insert to 8 in., PVC insert over 8 in.

3.0 - 12.0 in. Flow, pH3 in. max. 10.3 bar4-8 in. max. 6.9 bar10-12 in. max. 5.2 bar

3”-8” -15 °C - +100 °C10, 12” -15 °C - +65 °C 64

AB

S

Solvent cementing no gasket d25 - d63 Flow, pH max. 10 bar -40 °C - +60 °C 66

Solvent cementing no gasket d75 - d225 Flow max. 10 bar -40 °C - +60 °C 66

Met

als

NPT threaded

PVDF insert up to 8 in.PVC insert over 8 in.

0.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C – +100 °C 68

Sweat on

No insert up to 1 in.PVDF insert over 1 in.

0.50 - 1.50 in. Flow, pH max. 13.8 bar 0 °C – +60 °C 68

NPT threaded

no gasket/PVDF insert 1.0 - 2.0 in Flow, pH max. 13.8 bar -15 °C – +100 °C 68

NPT threaded PVDF insert 0.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C – +100 °C 70

NPT threaded PVDF insert 1.0 - 2.0 in Flow, pH – – 70

Weld-on

PVDF insert up to 8 in.PVC insert over 8 in.

2.5 - 12.0 in. Flow, pH max. 13.8 bar -15 °C – +100 °C 72

Braze

PVDF insert up to 8 in.PVC insert over 8 in.

2.5 - 12.0 in Flow, pH – – 72

Weld-on

PVDF insert up to 8 in.PVC insert over 8 in.

2.5 - 12 in. Flow, pH max. 13.8 bar -15 °C - +100 °C 74

Strap-on

Buna-N/PVDF insert up to 8 in.PVC insert over 8 in.

0.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C - +100 °C 74

Socket weld-on to SS pipe

no gasket 0.50 - 1.0 in525-1, 525-1S only

max. 16 bar – 76

Weld-on toSS pipe

Klinger C4401 Thermoseal 1.25 - 12.0 in

525-2, 525-2S only

max. 16 bar – 76

Strap-on Buna-N 2.0 - 12.0 in.525-3, 525-3S only

– – 76

Strap-on EPDM/NBR d60 - d355 Other max. 16 bar – 78

Elec

tro-

fusi

on

– – – – – – 80

Page 50: GF Piping Systems worldwide at home

50

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX• These fittings are only available from the Georg Fischer sales office in Japan.

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• These fittings are only available from the Georg Fischer sales office in Japan.

JIS PVC-U Tee Fittings

EPDM Code No. FPM Code No. DN [mm] Sensor Type

200 072 063 200 070 933 15 Flow -X0, pH -XX

200 072 064 200 070 934 20 Flow -X0, pH -XX

200 072 065 200 070 935 25 Flow -X0, pH -XX

200 072 066 200 070 936 32 Flow -X0, pH -XX

200 072 067 200 070 937 40 Flow -X0, pH -XX

200 072 068 200 070 902 50 Flow -X0, pH -XX

JIS PVC-U Tee Fittings (Flange Type)

Code No. DN [mm] Sensor Type

200 070 892 65 Flow -X0, pH -XX

200 070 893 80 Flow -X0, pH -XX

200 070 894 100 Flow -X0, pH -X1

200 070 895 125 Flow -X1

200 070 896 150 Flow -X1

200 070 897 200 Flow -X1

JIS

Flow and pH

Type 310, PVC-U for Socket Systems JIS

EPDM Code No.

FPM Code No.

d [mm]

DN [mm]

Sensor Type

721 310 506 721 310 536 20 15 Flow -X0, pH -XX

721 310 507 721 310 537 25 20 Flow -X0, pH -XX

721 310 508 721 310 538 32 25 Flow -X0, pH -XX

721 310 509 721 310 539 40 32 Flow -X0, pH -XX

721 310 510 721 310 540 50 40 Flow -X0, pH -XX

721 310 511 721 310 541 63 50 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Page 51: GF Piping Systems worldwide at home

51

JIS PVC-U Tee Fittings

d [mm]

H [mm]

H1 [mm]

L [mm]

L1 [mm]

22 145 225 468 90

26 148 228 144 100

32 151 231 160 110

38 155 235 168 110

48 159 239 188 120

60 164 244 212 130

JIS PVC-U Tee Fittings (Flange Type)

D [mm] DF DP L [mm]

76 175 140 57.2

89 185 150 56.8

114 210 175 56.9

140 250 210 82.0

165 280 240 77.8

216 330 290 71.6

DL

DF

DP

Tee

• Choice FPM or EPR (EPDM) O-ring• Appearance varies in DN15 mm

• Threaded outlet 1¼ inch NPSM• Union end with solvent cement socket• Sensor length depends on installation fitting

Type 310, PVC-U for Socket Systems JIS

d [mm]

PND [mm]

z [mm]

L [mm]

L1 [mm]

H[mm]

20 16 51 56 144 90 76

25 16 51 53 144 100 78

32 16 58 58 160 110 81

40 16 72 58 168 110 85

50 16 83 63 188 120 89

63 16 100 68 212 130 95

JIS

272X

515

2537

2536

2551

Page 52: GF Piping Systems worldwide at home

52

PVC-U

Flow and pH

Type 310, PVC-U for Socket Systems metric

Part No. EPDM Code No.

FPM Code No.

DN [mm]

Sensor Type

PVMT005 721 310 006 721 310 036 15 Flow -X0, pH -XX

PVMT007 721 310 007 721 310 037 20 Flow -X0, pH -XX

PVMT010 721 310 008 721 310 038 25 Flow -X0, pH -XX

PVMT012 721 310 009 721 310 039 32 Flow -X0, pH -XX

PVMT015 721 310 010 721 310 040 40 Flow -X0, pH -XX

PVMT020 721 310 011 721 310 041 50 Flow -X0, pH -XX

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX• Sensor length depends on installation fitting• These fittings are only available from your local Georg Fischer sales office

Type 312, PVC-U Clamp-on Saddle, metric

Part No. Code No.DN [mm]

Sensor Type

PVMS025 198 150 538 65 Flow -X0, pH-XX

PVMS030 198 150 539 80 Flow -X0, pH-XX

PVMS040 198 150 540 100 Flow -X0, pH-XX

PVMS060 198 150 543 150 Flow -X1

PVMS080 198 150 545 200 Flow -X1

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on page 139)• These fittings are only available from your local Georg Fischer sales office

Page 53: GF Piping Systems worldwide at home

53

Saddle

Tee

Type 310, PVC-U for Socket Systems metric

PNd [mm]

D [mm]

z [mm]

L[mm]

L1[mm]

H [mm]

16 20 43 48 128 90 76

16 25 51 53 144 100 78

16 32 58 58 160 110 81

16 40 72 58 168 110 85

16 50 83 63 188 120 89

16 63 100 68 212 130 95

Type 312, PVC-U Clamp-on Saddle, metric

PN d [mm] H [mm] L [mm]

16 75 99 105

16 90 105 105

16 110 114 105

16 160 156 120

16 225 184 120

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Top saddle for solvent cement bonding

PVC

-UP

VC-C

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting

272X

515

2537

2536

2551

Page 54: GF Piping Systems worldwide at home

54

PVC-U

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

PVC-U Tee SCH 80 - Fitting Only

Part No. Code No. Size [in.] Sensor Type

MPV8T005F 159 001 614 0.50 Flow -X0, pH -XX

MPV8T007F 159 001 615 0.75 Flow -X0, pH -XX

MPV8T010F 159 001 616 1.00 Flow -X0, pH -XX

MPV8T012F 159 001 617 1.25 Flow -X0, pH -XX

MPV8T015F 159 001 618 1.50 Flow -X0, pH -XX

MPV8T020F 159 001 619 2.00 Flow -X0, pH -XX

PVC-U Tee SCH 80 - with Pipe

Part No. Code No. Size [in.] Sensor Type

MPV8T005 159 001 623 0.50 Flow -X0, pH -XX

MPV8T007 159 001 624 0.75 Flow -X0, pH -XX

MPV8T010 159 001 625 1.00 Flow -X0, pH -XX

MPV8T012 159 001 626 1.25 Flow -X0, pH -XX

MPV8T015 159 001 627 1.50 Flow -X0, pH -XX

MPV8T020 159 001 628 2.00 Flow -X0, pH -XX

Page 55: GF Piping Systems worldwide at home

55

Tee

PVC

-UP

VC-C

PVC-U Tee SCH 80 - with Pipe1

L [in.] H [in.] o.d [in.]

14 3.50 0.84

14 3.70 1.05

17 4.00 1.32

20 4.30 1.66

24 4.60 1.90

26.5 5.02 2.38

PVC-U Tee SCH 80 - Fitting only

L [in.] H [in.] i.d [in.]

3.75 3.50 0.85

3.75 3.70 1.06

4.30 4.00 1.33

4.40 4.30 1.67

5.00 4.60 1.91

5.50 5.00 2.40

1Pipe lengths included with these fittings do not satisfy straight-run requirements for all installation configurations.

L

o.d.

H

L

i.d.

H

272X

515

2537

2536

2551

Page 56: GF Piping Systems worldwide at home

56

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX

PVC-U Clamp-on Saddles SCH 80

Part No. Code No. Size [in.] Sensor Type

PV8S020 159 000 637 2.00 Flow -X0, pH -XX

PV8S025 159 000 638 2.50 Flow -X0, pH -XX

PV8S030 198 150 577 3.00 Flow -X0, pH -XX

PV8S040 198 150 578 4.00 Flow -X0

PV8S060 198 150 579 6.00 Flow -X1

PV8S080 159 000 639 8.00 Flow -X1

• For use with P51530-X2, 3-2536-X2, 3-2551-X2-XX

PVC-U Glue-on Saddle Fitting SCH 80

Part No. Code No. Size [in.] Sensor Type

PV8S100 159 000 695 10.00 Flow -X2

PV8S120 159 000 696 12.00 Flow -X2

PVC-U

Flow and pH

Page 57: GF Piping Systems worldwide at home

57

Saddle

PVC-U Clamp-on Saddles SCH 80

L [in.] H [in.] d [in.] C [in.]

4.00 5.0 2.375 1.43

4.75 5.4 2.875 1.43

5.00 6.0 3.500 1.43

5.00 7.1 4.500 1.43

5.00 10.0 6.625 2.25

5.00 11.5 8.625 2.25

• Mounts on PVC pipe• C - Clearance dimension• EPR (EPDM) O-ring

PVC-U Clamp-on Saddles SCH 80

W [in.] H [in.] o.d. [in.] C [in.]

9.0 5.43 10.75 2.25

9.0 5.15 12.75 2.25

PVC

-UP

VC-C

272X

515

2537

2536

2551

Page 58: GF Piping Systems worldwide at home

58

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

PVC-C Tees SCH 80 - Fitting Only

Part No. Code No. Size [in.] Sensor Type

MCPV8T005F 159 001 632 0.50 Flow -X0, pH -XX

MCPV8T007F 159 001 633 0.75 Flow -X0, pH -XX

MCPV8T010F 159 001 634 1.00 Flow -X0, pH -XX

MCPV8T012F 159 001 635 1.25 Flow -X0, pH -XX

MCPV8T015F 159 001 636 1.50 Flow -X0, pH -XX

MCPV8T020F 159 001 637 2.00 Flow -X0, pH -XX

PVC-C Tees SCH 80 - with Pipe

Part No. Code No. Size [in.] Sensor Type

MCPV8T005 159 001 641 0.50 Flow -X0, pH -XX

MCPV8T007 159 001 642 0.75 Flow -X0, pH -XX

MCPV8T010 159 001 643 1.00 Flow -X0, pH -XX

MCPV8T012 159 001 644 1.25 Flow -X0, pH -XX

MCPV8T015 159 001 645 1.50 Flow -X0, pH -XX

MCPV8T020 159 001 646 2.00 Flow -X0, pH -XX

PVC-C

Flow and pH

Page 59: GF Piping Systems worldwide at home

59

515

2537

2536

2551

272X

1Pipe lengths included with these fittings do not satisfy straight-run requirements for all installation configurations.

PVC-C Tees SCH 80 - Fitting only

L [in.] H [in.] i.d [in.]

3.75 3.50 0.85

3.75 3.70 1.06

4.30 4.00 1.33

4.40 4.30 1.67

5.00 4.60 1.91

5.50 5.00 2.40

PVC-C Tees SCH 80 - with Pipe1

L [in.] H [in.] o.d [in.]

14 3.50 0.84

14 3.70 1.05

17 4.00 1.32

20 4.30 1.66

24 4.60 1.90

26.5 5.02 2.38

Tee

PVC

-UP

VC-Ci.d.

H

L

o.d.

L

H

Page 60: GF Piping Systems worldwide at home

60

PP

Flow and pH

Type 310, PROGEF Standard, PP-H for Socket Fusion, metric

Part No.EPDM Code No.

FPM Code No.

DN [mm]

Sensor Type

PPMT005 727 310 006 727 310 036 15 Flow -X0, pH -XX

PPMT007 727 310 007 727 310 037 20 Flow -X0, pH -XX

PPMT010 727 310 008 727 310 038 25 Flow -X0, pH -XX

PPMT012 727 310 009 727 310 039 32 Flow -X0, pH -XX

PPMT015 727 310 010 727 310 040 40 Flow -X0, pH -XX

PPMT020 727 310 011 727 310 041 50 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on pg 139)

• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX/X2-XX• Sensor length depends on installation fitting

Type 311, PP-H, Wafer fitting, metric and inch

Part No.EPDM Code No.

FPM Code No.

d [in.]

DN [mm]

Sensor Type

PPMTE025 727 311 012 727 311 042 2.50 65 Flow -X1

PPMTE030 727 311 013 727 311 043 3.00 80 Flow -X1

PPMTE040 727 311 014 727 311 044 4.00 100 Flow -X1

727 311 015 727 311 045 4.00 100 Flow -X1

PPMTE050 727 311 016 727 311 046 5.00 125 Flow -X1

PPMTE060 727 311 017 727 311 047 6.00 150 Flow -X1

727 311 018 727 311 048 6.00 150 Flow -X1

727 311 019 727 311 049 8.00 200 Flow -X1

PPMTE080 727 311 020 727 311 050 8.00 200 Flow -X1

727 311 021 727 311 051 10.0 250 Flow -X2

PPMTE100 727 311 022 727 311 052 10.0 250 Flow -X2

PPMTE120 727 311 023 727 311 053 12.0 300 Flow -X2

Page 61: GF Piping Systems worldwide at home

61

Tee

Type 310, PROGEF Standard, PP-H for Socket Fusion, metric

PNd [mm]

D [mm]

Z [mm]

L [mm]

L1 [mm]

H [mm]

10 20 48 50 128 90 76

10 25 58 55 142 100 78

10 32 65 60 156 110 81

10 40 79 60 160 110 85

10 50 91 65 176 120 89

10 63 105 70 194 130 95 PP

• Threaded outlet 1¼ inch NPSM• Union end with fusion socket PP-H• FPM are generally stock items

272X

515

2537

2536

2551

WaferType 311, PP-H, Wafer fitting, metric and inch

PNd [mm]

D [mm]

H[mm]

L[mm]

L1 [mm]

16 75 88 133 48 61

16 90 102 140 48 69

16 110 132 145 48 79

16 125 132 144 48 79

16 140 157 149 48 94

16 160 182 156 48 106

16 180 182 163 48 106

16 200 236 170 48 134

16 225 236 178 48 134

16 250 289 263 48 160

16 280 289 273 48 160

16 315 329 285 48 185

d

G

• Threaded outlet 1¼ NPSM• Suitable for backing flanges metric and inch• Suitable for SDR 11 - SDR 17.6• Delivered with profile O-ring• Wafer can be used with other pipe materials• Sensor length depends on installation fitting

Page 62: GF Piping Systems worldwide at home

62

PVDF

Flow and pH

Type 311, SYGEF Standard, PVDF, metric & inch

Part No. FPM Code No.d [in.]

DN [mm]

Sensor Type

SFMTF025 735 311 042 2.50 65 Flow -X1

SFMTF030 735 311 043 3.00 80 Flow -X1

SFMTF040 735 311 044 4.00 100 Flow -X1

735 311 045 4.00 100 Flow -X1

SFMTF050 735 311 046 5.00 125 Flow -X1

SFMTF060 735 311 047 6.00 150 Flow -X1

735 310 049 8.00 200 Flow -X1

SFMTF080 735 311 050 8.00 200 Flow -X1

Type 310, SYGEF Standard, PVDF, Socket Fusion, metric

Part No. FPM Code No.DN [mm]

Sensor Type

SFMT005 735 310 036 15 Flow -X0, pH -XX

SFMT007 735 310 037 20 Flow -X0, pH -XX

SFMT010 735 310 038 25 Flow -X0, pH -XX

SFMT012 735 310 039 32 Flow -X0, pH -XX

SFMT015 735 310 040 40 Flow -X0, pH -XX

SFMT020 735 310 041 50 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting• To install this installation fitting in PVC-C, PP-R and PE pipes. Replace the original union ends by PVC-C, PP-R and PE union ends. (See table on pg 139)

• For use with P51530-X1, 3-2536-X1, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX• Sensor length depends on installation fitting

Page 63: GF Piping Systems worldwide at home

63

Type 311, SYGEF Standard, PVDF, metric & inch

PNd [mm]

H [mm]

D [mm]

L [mm]

L1 [mm]

10/16 75 135 88 48 61

10/16 90 141 102 48 69

10/16 110 148 132 48 79

10/16 125 147 132 48 79

10/16 140 153 157 48 94

10/16 160 161 482 48 106

10/16 200 175 236 48 134

10/16 225 185 236 48 134

d

G

TeeType 310, SYGEF Standard, PVDF, Socket Fusion,

metric

PNd [mm]

D [mm]

Z [mm]

L [mm]

L1 [mm]

H [mm]

16 20 45 50 128 90 76

16 25 55 55 142 100 78

16 32m 62 60 156 110 81

16 40 75 60 160 110 85

16 50 84 65 176 120 89

16 63 101 70 194 130 95

Wafer

PVD

F

• Socket fusion equipment is required to install PVDF union tees• FPM O-rings• Sensor length depends on installation fitting

• Threaded outlet 1¼ inch NPSM• Suitable for backing flanges metric and inch• Delivered with profile O-ring• Wafer can be used with other pipe materials• Sensor length depends on installation fitting

272X

515

2537

2536

2551

Page 64: GF Piping Systems worldwide at home

64

Fibreglass

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Fibreglass Glue-on Tees

Part No. Code No. Size [in.] Sensor Type

FPT015 159 000 446 1.50 Flow -X0, pH -XX

FPT020 159 000 447 2.00 Flow -X0, pH -XX

Fibreglass Glue-on Saddles

Part No. Code No. Size [in.] Sensor Type

FPS030 159 000 441 3.00 Flow -X0, pH -XX

FPS040 159 000 442 4.00 Flow -X0, pH -XX

FPS060 159 000 443 6.00 Flow -X1

FPS080 198 801 417 8.00 Flow -X1

FPS0100 159 000 444 10.00 Flow -X2

FPS0120 159 000 445 12.00 Flow -X2

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Page 65: GF Piping Systems worldwide at home

65

• PVDF insert - all sizes• PTFE wetted material. Contact factory for available options

Fibreglass Glue-on Tees

L [in.] H [in.] i.d. [in.]

5.5 4.7 1.92

7.7 8.0 2.38

Fibreglass Glue-on Saddles

L [in.] H [in.] o.d. [in.] C [in.]

5.9 4.5 3.50 1.44

8.0 4.5 4.50 1.44

8.0 6.5 6.62 2.25

10.0 8.0 8.62 2.25

12.0 8.5 10.75 2.25

12.0 8.5 12.75 2.25

Saddle

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC• Mounts on fibreglass pipe• PTFE wetted material. Contact factory for available options.• Custom sizes available

H

L

i.d.

H C

L

Tee

Fibr

e-gl

ass

272X

515

2537

2536

2551

Page 66: GF Piping Systems worldwide at home

66

ABS

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX• Sensor length depends on installation fitting

Type 310, ABS, metric

Code No.d [mm]

DN [mm]

Sensor Type

729 310 007 25 20 Flow -X0, pH -XX

729 310 008 32 25 Flow -X0, pH -XX

729 310 009 40 32 Flow -X0, pH -XX

729 310 010 50 40 Flow -X0, pH -XX

729 310 011 63 50 Flow -X0, pH -XX

• For use with P51530-X1, 3-2536-X1, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX• Sensor length depends on installation fitting

Type 312, ABS Glue-on saddle, metric

Code No.d [mm]

DN [mm]

Sensor Type

729 312 012 75 65 Flow -X1

729 312 013 90 80 Flow -X1

729 312 014 110 100 Flow -X1

729 312 016 140 125 Flow -X1

729 312 017 160 150 Flow -X1

729 312 019 200 200 Flow -X1

729 312 020 225 200 Flow -X1

Page 67: GF Piping Systems worldwide at home

67

AB

S

Saddle

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• With solvent cement socket metric

Type 310, ABS, metric

PNd [mm]

D [mm]

L[mm]

H[mm]

z[mm]

closest [inch]

10 25 35 100 78 32 0.75

10 32 44 110 81 33 1.00

10 40 51 110 85 29 1.25

10 50 63 120 89 29 1.50

10 63 78 130 95 28 2.00

• Threaded outlet 1¼ inch NPSM• Sensor length depends on installation fitting• Top saddle for solvent cement bonding

Type 312, ABS Glue-on saddle, metric

PNd [mm]

D [mm]

H[mm]

closest [inch]

10 75 38 91 2.50

10 90 38 91 3.00

10 110 38 91 4.00

10 140 38 81 5.00

10 160 38 77 6.00

10 200 38 71 8.00

10 225 38 67 8.00

Tee

272X

515

2537

2536

2551

Page 68: GF Piping Systems worldwide at home

68

Metals

Flow and pH

Carbon Steel Threaded Tees with NPT Threads

Part No. Code No. Size [in.] Sensor Type

CS4T005 198 801 459 0.50 Flow -X0, pH -XX

CS4T007 198 801 460 0.75 Flow -X0, pH -XX

CS4T010 198 801 461 1.00 Flow -X0, pH -XX

CS4T012 198 801 462 1.25 Flow -X0, pH -XX

CS4T015 198 801 419 1.50 Flow -X0, pH -XX

CS4T020 198 801 463 2.00 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Copper Sweat-on Tee with PVDF insert

Part No. Code No. Size [in.] Sensor Type

CUKT005 198 801 687 0.50 Flow -X0, pH -XX

CUKT007 198 801 688 0.75 Flow -X0, pH -XX

CUKT010 198 801 689 1.00 Flow -X0, pH -XX

CUKT012 198 801 690 1.25 Flow -X0, pH -XX

CUKT015 198 801 691 1.50 Flow -X0, pH -XX

CUKT020 198 801 418 2.00 Flow -X0, pH -XX

Galvanized Iron Threaded Tee with NPT Threads and PVDF insert

Part No. Code No. Size [in.] Sensor Type

IR4T010 198 801 421 1.00 Flow -X0, pH -XX

IR4T012 198 801 422 1.25 Flow -X0, pH -XX

IR4T015 198 801 423 1.50 Flow -X0, pH -XX

IR4T020 198 801 424 2.00 Flow -X0, pH -XX

Page 69: GF Piping Systems worldwide at home

69

H

LNPT

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

• No insert up to 1 in., over 1 in. - PVDF insert• For use with copper pipe (SCH K)• PTFE wetted material. Contact factory for available options.

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

Carbon Steel Threaded Tees with NPT Threads

L [in.] H [in.]

3.6 4.0

3.6 4.2

3.6 4.2

3.8 4.5

4.1 4.8

4.9 5.3

Copper Sweat-on Tee with PVDF insert

L [in.] H [in.] i.d. [in.]

3.15 3.57 0.62

2.96 3.52 0.87

3.23 3.80 1.12

4.16 4.12 1.38

4.43 4.34 1.63

5.31 4.86 2.11

Galvanized Iron Threaded Tee with NPT Threads and PVDF insert

NPT L [in.] H [in.]

1.00 3.4 4.1

1.25 3.56 4.34

1.50 3.75 4.67

2.00 3.90 5.05

Tee

Met

als

272X

515

2537

2536

2551

Page 70: GF Piping Systems worldwide at home

70

Metals

Flow and pH

316 SS (1.4401) Threaded Tees with NPT Threads and PVDF insert

Part No. Code No. Size [in.] Sensor Type

CR4T005 198 801 554 0.50 Flow -X0, pH -XX

CR4T007 198 801 555 0.75 Flow -X0, pH -XX

CR4T010 198 801 556 1.00 Flow -X0, pH -XX

CR4T012 198 801 783 1.25 Flow -X0, pH -XX

CR4T015 198 801 784 1.50 Flow -X0, pH -XX

CR4T020 198 801 785 2.00 Flow -X0, pH -XX

Brass Threaded Tee with NPT Threads and PVDF insert

Part No. Code No. Size [in.] Sensor Type

BR4T010 198 801 770 1.00 Flow -X0, pH -XX

BR4T012 198 801 771 1.25 Flow -X0, pH -XX

BR4T015 198 801 772 1.50 Flow -X0, pH -XX

BR4T020 198 801 773 2.00 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Page 71: GF Piping Systems worldwide at home

71

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

Brass Threaded Tee with NPT Threads and PVDF insert

NPT [in.] L [in.] H [in.]

1.00 3.36 4.09

1.25 3.42 4.42

1.50 3.46 4.70

2.00 3.68 5.19

316 SS (1.4401) Threaded Tees with NPT Threads and PVDF insert

L [in.] H [in.]

3.6 4.0

3.6 4.2

3.6 4.2

3.8 4.5

4.1 4.8

4.9 5.3

H

LNPT

Tee

Met

als

272X

515

2537

2536

2551

Page 72: GF Piping Systems worldwide at home

72

Metals

Flow and pH

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Brass Brazolet with PVDF insert for use with copper pipe (SCH 40 ASTM)

Part No. Code No. Size [in.] Sensor Type

BR4B025 198 801 794 2.50 Flow -X0, pH-XX

BR4B030 198 801 795 3.00 Flow -X0, pH -XX

BR4B040 198 801 796 4.00 Flow -X0, pH -XX

BR4B050 198 801 797 5.00 Flow -X1

BR4B060 198 801 798 6.00 Flow -X1

BR4B080 198 801 799 8.00 Flow -X1

BR4B100 198 801 800 10.0 Flow -X2

BR4B120 198 801 801 12.0 Flow -X2

Carbon Steel Weld-on Weldolets for use with SCH 40 metal pipe (ASTM)

Part No. Code Size [in.] Sensor Type

CS4W025 198 801 464 2.50 Flow -X0, pH-XX

CS4W030 198 801 557 3.00 Flow -X0, pH -XX

CS4W040 198 801 552 4.00 Flow -X0, pH -XX

CS4W050 198 801 465 5.00 Flow -X1

CS4W060 198 801 553 6.00 Flow -X1

CS4W080 198 801 574 8.00 Flow -X1

CS4W100 198 801 575 10.0 Flow -X2

CS4W120 198 801 576 12.0 Flow -X2

Page 73: GF Piping Systems worldwide at home

73

Brass Brazolet with PVDF insert for use with cop-per pipe (SCH 40 ASTM)

W [in.] H [in.] C [in.]

2.50 2.48 1.31

2.50 2.47 1.31

2.50 2.45 1.31

3.50 3.24 2.10

3.50 3.11 2.10

3.50 2.88 2.10

3.50 5.63 2.10

3.50 5.40 2.10

Carbon Steel Weld-on Weldolets for use with SCH 40 metal pipe (ASTM)

W [in.] H [in.] C [in.]

2.60 2.48 1.31

2.60 2.47 1.31

2.60 2.45 1.31

3.50 3.24 2.10

3.50 3.11 2.10

3.50 2.88 2.10

3.50 5.63 2.10

3.50 5.40 2.10

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• PTFE wetted material. Contact factory for available options.

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• PTFE wetted material. Contact factory for available options.

Tee

Met

als

272X

515

2537

2536

2551

Page 74: GF Piping Systems worldwide at home

74

Metals

Flow and pH

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Iron Strap-on Saddle for use with SCH 80 metal pipe (ASTM)

Part No. Code No. Size [in.] Sensor Type

IR8S020 198 801 425 2.00 Flow -X0, pH -XX

IR8S025 198 801 426 2.50 Flow -X0, pH -XX

IR8S030 198 801 427 3.00 Flow -X0, pH -XX

IR8S040 198 801 420 4.00 Flow -X0, pH -XX

IR8S050 198 801 429 5.00 Flow -X1

IR8S060 198 801 430 6.00 Flow -X1

IR8S080 198 801 431 8.00 Flow -X1

IR8S100 198 801 432 10.0 Flow -X2

IR8S120 198 801 433 12.0 Flow -X2

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

316 SS (1.4401) Weldolets with PVDF insert for use with SCH 40 metal pipe (ASTM)

Part No. Code No. Size [in.] Sensor Type

CR4W025 198 801 786 2.50 Flow -X0, pH -XX

CR4W030 198 801 787 3.00 Flow -X0, pH -XX

CR4W040 198 801 788 4.00 Flow -X0, pH -XX

CR4W050 198 801 789 5.00 Flow -X1

CR4W060 198 801 790 6.00 Flow -X1

CR4W080 198 801 791 8.00 Flow -X1

CR4W100 198 801 792 10.0 Flow -X2

CR4W120 198 801 793 12.0 Flow -X2

Page 75: GF Piping Systems worldwide at home

75

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• Buna-N O-ring• Larger sizes may be available and PTFE wetted material. Contact factory.

Iron Strap-on Saddle for use with SCH 80 metal pipe (ASTM)

H [in.]

o.d. min [in.]

o.d. max [in.]

C [in.]

5.5 2.35 2.56 1.44

5.5 2.44 2.91 1.44

6.5 2.97 3.54 1.44

7.5 3.74 4.55 2.25

9.0 4.74 5.63 2.25

10.5 5.94 6.70 2.25

12.0 7.69 8.72 2.25

18.0 10.64 12.12 2.25

20.0 12.62 14.32 2.25

• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• C - Clearance dimension• PTFE wetted material. Contact factory for available options.

316 SS (1.4401) Weldolets with PVDF insert for use with SCH 40 metal pipe (ASTM)

W [in.] H [in.] C [in.]

2.50 2.48 1.31

2.50 2.47 1.31

2.50 2.45 1.31

3.50 3.24 2.10

3.50 3.11 2.10

3.50 2.88 2.10

3.50 5.63 2.10

3.50 5.40 2.10

Tee

Met

als

272X

515

2537

2536

2551

Page 76: GF Piping Systems worldwide at home

76

• For use with P525-1 and P525-1S only

Metalex Socket Weld Mini-Tap (1.4401)

Part No. Code No. DN [mm] Size [in.] Sensor Type

P526-2005 198 840 501 15 0.50 P525-1, -1S

P526-2007 198 840 502 20 0.75 P525-1, -1S

P526-2010 198 840 503 25 1.00 P525-1, -1S

• For use with P525-2 and P525-2S only

Metalex Weld-on Mini-Tap (1.4401)

Part No. Code No. Size [in.] Sensor Type

P526-2012 159 000 494 1.25 P525-2, -2S

P526-2015 198 840 506 1.50 P525-2, -2S

P526-2020 159 000 495 2.00 P525-2, -2S

P526-2025 159 000 496 2.50 P525-2, -2S

P526-2030 159 000 497 3.00 P525-2, -2S

P526-2040 159 000 498 4.00 P525-2, -2S

P526-2050 159 000 499 5.00 P525-2, -2S

P526-2060 159 000 500 6.00 P525-2, -2S

P526-2080 159 000 501 8.00 P525-2, -2S

P526-2100 159 000 502 10.00 P525-2, -2S

P526-2120 159 000 503 12.00 P525-2, -2S

Metalex Strap-on Saddle (1.4401)

Part No. Code No. Size [in.] Sensor Type

P526-1020 159 000 484 2.00 P525-3, -3S

P526-1025 159 000 485 2.50 P525-3, -3S

P526-1030 159 000 486 3.00 P525-3, -3S

P526-1040 159 000 487 4.00 P525-3, -3S

P526-1050 159 000 488 5.00 P525-3, -3S

P526-1060 159 000 489 6.00 P525-3, -3S

P526-1080 159 000 490 8.00 P525-3, -3S

P526-1100 159 000 491 10.00 P525-3, -3S

P526-1120 159 000 492 12.00 P525-3, -3S

• For use with P525-3 and P525-3S only

Metals

Flow and pH

Page 77: GF Piping Systems worldwide at home

77

525

• For use with SS pipe

Metalex Socket Weld Mini-Tap (1.4401)D [mm]

H [mm]

L [in.]

W [in.]

H [in.]

i.d. [in.]

21.8 8.4 2.0 2.4 3.0 0.85

27.2 12.7 2.0 2.4 3.0 1.06

33.9 12.7 2.0 2.4 3.0 1.325

• For use with SS pipe• Gasket Klinger C4401 Thermoseal

Metalex Weld-on Mini-Tap (1.4401)

W [in.] H [in.] C [in.]

1.66 2.25 1.26

1.66 2.20 1.26

1.66 2.17 1.26

1.66 2.10 1.26

1.66 2.00 1.26

1.66 1.95 1.26

1.66 1.83 1.26

1.66 1.75 1.26

1.66 1.56 1.26

1.66 1.35 1.26

1.66 1.15 1.26

Metalex Strap-on Saddle (1.4401)W [in.]

H [in.]

o.d. min [in.]

o.d. max [in.]

5.5 7.0 2.35 2.56

5.5 7.0 2.44 2.91

6.0 7.5 2.97 3.54

7.0 8.0 3.74 4.55

8.0 10.0 4.74 5.63

9.5 10.5 5.94 6.70

12.0 12.75 7.69 8.72

15.0 14.5 10.64 12.12

17.0 17.0 12.62 14.32

• For use with SS pipe

W

H

o.d.

H

CW

Weld-on mini-tap

75D

DN

H

61

49

i.d.H

W

L

Met

als

Page 78: GF Piping Systems worldwide at home

78

Metals

Flow and Other Sensors

• Ready to install, studs and nuts in one package• Do not use these fittings for PE pipes

Multi/Saddle Plus Spatula for use with Iron Multi/Saddle Plus 201

Code No. Description

709 613 904 Spatula for saddle outlet 1¼ inch

709 613 905 Spatula for saddle outlet 1½ inch / d40 + d50

• Do not use these fittings for PE pipes

Multi/Saddle Straps for use with Iron Multi/Saddle Plus 201

Code No. Strap Range [in.] DN min [mm]

DN max [mm]

709 613 930 2.375 3.25 60 80

709 613 932 2.75 3.625 70 90

709 613 934 3.625 4.375 90 110

709 613 936 4.375 5.25 110 130

709 613 938 5.25 6.00 130 150

709 613 940 5.75 6.625 145 165

709 613 942 6.375 7.25 160 180

709 613 944 7.00 7.75 175 195

709 613 946 7.625 8.375 190 210

709 613 948 8.25 9.00 205 225

709 613 950 8.75 9.625 220 240

709 613 952 9.375 10.25 235 255

709 613 954 10.00 10.75 250 270

709 613 956 10.75 11.625 270 290

709 613 958 11.375 12.25 285 305

709 613 960 12.00 12.75 300 320

709 613 962 12.625 13.375 315 335

709 613 964 13.375 14.25 335 355

• For use with 3-2552-2X/-3X, 3-2540-XX, 3-3719-11 Wet-Tap assembly with the 3-275X-WTX Wet-Tap electrode• Do not use these fittings for PE pipes• 1½ and 2 inch saddles must be applied for pipes DN80 or larger

Iron Multi/Saddle Plus 201

EPDM Code NBR Code Inch PN Water

PNGas Sensor Type

709 613 736 709 613 836 1.25 16.0 5.0 2552-2

709 613 738 709 613 838 1.50 16.0 5.0 2552-3, 2540-XX, 3719-11

Page 79: GF Piping Systems worldwide at home

79

3719

2552

2540

Met

als

Multi/Saddle

Hot Tap Adaptor Multi/Saddle Plus 201

Code No. Inch

709 613 638 1½

Page 80: GF Piping Systems worldwide at home

80

ElectrofusionFlow and pH

Electrofusion for PE pipes: Transition Saddles with Stainless 1¼ inch Outlet

Part No. Size [in.] Sensor Type

10004673 2.0 2552-1

10004686 3.0 2552-1

10004700 4.0 2552-1

10004717 6.0 2552-1

10004740 8.0 2552-1

Special request 10.0 2552-1 or -2

Special request 12.0 2552-1 or -2

1½ inch outlet

10004676 2.0 2552-3, 2540-XX, 3719-11

10004689 3.0 2552-3, 2540-XX, 3719-11

10004703 4.0 2552-3, 2540-XX, 3719-11

10004720 6.0 2552-3, 2540-XX, 3719-11

10004743 8.0 2552-3, 2540-XX, 3719-11

Special request 10.0 2552-3, 2540-XX, 3719-11

Special request 12.0 2552-3, 2540-XX, 3719-11

• Transition saddle with 1¼ FNPT branch/outlet• Transition saddle with 1½ FNPT branch/outlet• These fittings are only available from your local Georg Fischer sales office

Page 81: GF Piping Systems worldwide at home

81

3719

2552

2540

Electrofusion

Electrofusion for PE pipes: Transition Saddles with Stainless Outlet

L [in.] H [in.] d [in.]

3.6 3.18 N/A

4.6 3.18 N/A

6.26 3.8 N/A

8.68 4.96 N/A

5.92 2.96 N/A

Call Call N/A

Call Call N/A

3.6 3.18 N/A

4.6 3.18 N/A

6.26 3.8 N/A

8.68 4.96 N/A

5.92 2.96 N/A

Call Call N/A

Call Call N/A Elec

tro-

Fusi

on

Page 82: GF Piping Systems worldwide at home

82

Material Fitting Joint Gasket Dimension Sensor Type Pressure Temperature Page

PVC

Solvent Cementing FPM 0.50 - 2.0 in. Flow, pH max. 16 bar 0 °C – +60 °C 84

Solvent Cementing no gasket 0.50 - 2.0 in. Flow, pH max. 13.8 bar 0 °C – +60 °C 86

Hot gas back welding no gasket 0.50 - 2.0 in. Flow, pH max. 12.6 bar 0 °C – +60 °C 86

Clamp-on saddle EPDM 2.0 - 8.0 in. Flow, pH max. 12.6 bar 0 °C – +60 °C 88

Glue-on saddle no gasket 10 - 12 in. Flow max. 16 bar 0 °C – +60 °C 88

CP

VC

Solvent Cementing no gasket 0.50 - 2.0 in. Flow, pH max. 13.8 bar 0 °C – +100 °C 90

Solvent Cementing no gasket 0.50 - 2.0 in. Flow, pH max. 13.8 bar 0 °C – +100 °C 90

PP

Socket Fusion EPDM/FPM d20 - d63 Flow, pH max. 16 bar -10 °C – +95 °C 92

Flange adapters EPDM/FPM d75 - d315 Flow max. 16 bar -10 °C – +95 °C 92

PVD

F

Flange adapters FPM d75 - d225 Flow max. 16 bar -20 °C – +140 °C 94

Socket fusion FPM d20 - d63 Flow, pH max. 16 bar -20 °C – +140 °C 94

Fibe

rgla

ss

Solvent cementing PVDF insert 1.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C - +100 °C 96

Solvent cementing

PVDF insert to 8 in., PVC insert over 8 in.

3.0 - 12.0 in. Flow, pH3 in. max. 10.3 bar4-8 in. max. 6.9 bar10-12 in. max. 5.2 bar

3”-8” -15 °C - +100 °C10, 12” -15 °C - +65 °C 96

Table of Contents

USA Fittings

Page 83: GF Piping Systems worldwide at home

83

Material Fitting Joint Gasket Dimension Sensor Type Pressure Temperature Page

Met

als

NPT threadedPVDF insert up to 8 in.PVC insert over 8 in.

0.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C – +100 °C 98

Sweat on

No insert up to 1 in.PVDF insert over 1 in.

0.50 - 1.50 in. Flow, pH max. 13.8 bar 0 °C – +60 °C 98

NPT threaded no gasket/PVDF insert 1.0 - 2.0 in Flow, pH max. 13.8 bar -15 °C – +100 °C 98

NPT threaded PVDF insert 0.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C – +100 °C 100

NPT threaded PVDF insert 1.0 - 2.0 in Flow, pH – – 100

Weld-on

PVDF insert up to 8 in.PVC insert over 8 in.

2.5 - 12.0 in. Flow, pH max. 13.8 bar -15 °C – +100 °C 102

Braze

PVDF insert up to 8 in.PVC insert over 8 in.

2.5 - 12.0 in Flow, pH – – 102

Weld-on

PVDF insert up to 8 in.PVC insert over 8 in.

2.5 - 12 in. Flow, pH max. 13.8 bar -15 °C - +100 °C 104

Strap-on

Buna-N/PVDF insert up to 8 in.PVC insert over 8 in.

0.50 - 2.0 in. Flow, pH max. 13.8 bar -15 °C - +100 °C 104

Socket weld-on to SS pipe – 0.50 - 1.0 in

525-1, 525-1S only

– – 106

Weld-on toSS pipe

Klinger C4401 Thermoseal 1.25 - 12.0 in

525-2, 525-2S only

– – 106

Strap-on Buna-N 2.0 - 12.0 in.525-3, 525-3S only

– – 106

Strap-on EPDM/NBR d60 - d355 Other max. 16 bar – 108

Elec

trof

usio

n

– – – – – – 110

USA

USA

Page 84: GF Piping Systems worldwide at home

84

PVC

Flow and pH

Type 310, PVC for Socket Systems ASTM inch

EPDM Code No.

FPM Code No.

d [in.]

DN [mm]

Sensor Type

721 310 406 721 310 436 ½ in. 15 mm Flow -X0, pH -XX

721 310 407 721 310 437 ¾ in. 20 mm Flow -X0, pH -XX

721 310 408 721 310 438 1 in. 25 mm Flow -X0, pH -XX

721 310 409 721 310 439 1¼ in. 32 mm Flow -X0, pH -XX

721 310 410 721 310 440 1½ in. 40 mm Flow -X0, pH -XX

721 310 411 721 310 441 2 in. 50 mm Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0, 3-272X-XX• These fittings are only available from your local Georg Fischer sales office

Page 85: GF Piping Systems worldwide at home

85

Tee

PVC

CP

VC

Type 310, PVC for Socket Systems ASTM inch

PND [mm]

z [mm]

L [mm]

L1 [mm]

H [mm]

16 43 48 140 90 76

16 51 53 156 100 78

16 58 58 174 110 81

16 72 58 180 110 85

16 83 63 196 120 89

16 100 68 212 130 95

272X

515

2537

2536

2551

Page 86: GF Piping Systems worldwide at home

86

PVC

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

PVC Tee SCH 80 - Fitting Only

Part No. Code No. Size [in.] Sensor Type

MPV8T005F 159 001 614 0.50 Flow -X0, pH -XX

MPV8T007F 159 001 615 0.75 Flow -X0, pH -XX

MPV8T010F 159 001 616 1.00 Flow -X0, pH -XX

MPV8T012F 159 001 617 1.25 Flow -X0, pH -XX

MPV8T015F 159 001 618 1.50 Flow -X0, pH -XX

MPV8T020F 159 001 619 2.00 Flow -X0, pH -XX

PVC Tee SCH 80 - with Pipe

Part No. Code No. Size [in.] Sensor Type

MPV8T005 159 001 623 0.50 Flow -X0, pH -XX

MPV8T007 159 001 624 0.75 Flow -X0, pH -XX

MPV8T010 159 001 625 1.00 Flow -X0, pH -XX

MPV8T012 159 001 626 1.25 Flow -X0, pH -XX

MPV8T015 159 001 627 1.50 Flow -X0, pH -XX

MPV8T020 159 001 628 2.00 Flow -X0, pH -XX

Page 87: GF Piping Systems worldwide at home

87

Tee

PVC Tee SCH 80 - with Pipe1

L [in.] H [in.] o.d [in.]

14 3.50 0.84

14 3.70 1.05

17 4.00 1.32

20 4.30 1.66

24 4.60 1.90

26.5 5.02 2.38

PVC Tee SCH 80 - Fitting only

L [in.] H [in.] i.d [in.]

3.75 3.50 0.85

3.75 3.70 1.06

4.30 4.00 1.33

4.40 4.30 1.67

5.00 4.60 1.91

5.50 5.00 2.40

1Pipe lengths included with these fittings do not satisfy straight-run requirements for all installation configurations.

PVC

CP

VC

L

o.d.

H

L

i.d.

H

272X

515

2537

2536

2551

Page 88: GF Piping Systems worldwide at home

88

PVC

Flow and pH

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX

PVC Clamp-on Saddles SCH 80

Part No. Code No. Size [in.] Sensor Type

PV8S020 159 000 637 2.00 Flow -X0, pH -XX

PV8S025 159 000 638 2.50 Flow -X0, pH -XX

PV8S030 198 150 577 3.00 Flow -X0, pH -XX

PV8S040 198 150 578 4.00 Flow -X0

PV8S060 198 150 579 6.00 Flow -X1

PV8S080 159 000 639 8.00 Flow -X1

• For use with P51530-X2, 3-2536-X2, 3-2551-X2-XX

PVC Glue-on Saddle Fitting SCH 80

Part No. Code No. Size [in.] Sensor Type

PV8S100 159 000 695 10.00 Flow -X2

PV8S120 159 000 696 12.00 Flow -X2

Page 89: GF Piping Systems worldwide at home

89

Saddle

PVC Clamp-on Saddles SCH 80

L [in.] H [in.] d [in.] C [in.]

4.00 5.0 2.375 1.43

4.75 5.4 2.875 1.43

5.00 6.0 3.500 1.43

5.00 7.1 4.500 1.43

5.00 10.0 6.625 2.25

5.00 11.5 8.625 2.25

• Mounts on PVC pipe• C - Clearance dimension• EPR (EPDM) O-ring

PVC Clamp-on Saddles SCH 80

W [in.] H [in.] o.d. [in.] C [in.]

9.0 5.43 10.75 2.25

9.0 5.15 12.75 2.25P

VCC

PVC

272X

515

2537

2536

2551

Page 90: GF Piping Systems worldwide at home

90

CPVC

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

PVC-C Tees SCH 80 - Fitting Only

Part No. Code No. Size [in.] Sensor Type

MCPV8T005F 159 001 632 0.50 Flow -X0, pH -XX

MCPV8T007F 159 001 633 0.75 Flow -X0, pH -XX

MCPV8T010F 159 001 634 1.00 Flow -X0, pH -XX

MCPV8T012F 159 001 635 1.25 Flow -X0, pH -XX

MCPV8T015F 159 001 636 1.50 Flow -X0, pH -XX

MCPV8T020F 159 001 637 2.00 Flow -X0, pH -XX

PVC-C Tees SCH 80 - with Pipe

Part No. Code No. Size [in.] Sensor Type

MCPV8T005 159 001 641 0.50 Flow -X0, pH -XX

MCPV8T007 159 001 642 0.75 Flow -X0, pH -XX

MCPV8T010 159 001 643 1.00 Flow -X0, pH -XX

MCPV8T012 159 001 644 1.25 Flow -X0, pH -XX

MCPV8T015 159 001 645 1.50 Flow -X0, pH -XX

MCPV8T020 159 001 646 2.00 Flow -X0, pH -XX

Page 91: GF Piping Systems worldwide at home

91

272X

PVC

CP

VC

515

2537

2536

2551

1Pipe lengths included with these fittings do not satisfy straight-run requirements for all installation configurations.

PVC-C Tees SCH 80 - Fitting only

L [in.] H [in.] i.d [in.]

3.75 3.50 0.85

3.75 3.70 1.06

4.30 4.00 1.33

4.40 4.30 1.67

5.00 4.60 1.91

5.50 5.00 2.40

PVC-C Tees SCH 80 - with Pipe1

L [in.] H [in.] o.d [in.]

14 3.50 0.84

14 3.70 1.05

17 4.00 1.32

20 4.30 1.66

24 4.60 1.90

26.5 5.02 2.38

Tee

i.d.

H

L

o.d.

L

H

Page 92: GF Piping Systems worldwide at home

92

PP

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Type 310, PROGEF Standard, PP-H for Socket Fusion, metric

Part No.EPDM Code No.

FPM Code No.

DN [mm]

Sensor Type

PPMT005 727 310 006 727 310 036 15 Flow -X0, pH -XX

PPMT007 727 310 007 727 310 037 20 Flow -X0, pH -XX

PPMT010 727 310 008 727 310 038 25 Flow -X0, pH -XX

PPMT012 727 310 009 727 310 039 32 Flow -X0, pH -XX

PPMT015 727 310 010 727 310 040 40 Flow -X0, pH -XX

PPMT020 727 310 011 727 310 041 50 Flow -X0, pH -XX

• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX/X2-XX

Type 311, PP-H, Wafer fitting, metric and inch

Part No.EPDM Code No.

FPM Code No.

d [in.]

DN [mm]

Sensor Type

PPMTE025 727 311 012 727 311 042 2.50 65 Flow -X1

PPMTE030 727 311 013 727 311 043 3.00 80 Flow -X1

PPMTE040 727 311 014 727 311 044 4.00 100 Flow -X1

727 311 015 727 311 045 4.00 100 Flow -X1

PPMTE050 727 311 016 727 311 046 5.00 125 Flow -X1

PPMTE060 727 311 017 727 311 047 6.00 150 Flow -X1

727 311 018 727 311 048 6.00 150 Flow -X1

727 311 019 727 311 049 8.00 200 Flow -X1

PPMTE080 727 311 020 727 311 050 8.00 200 Flow -X1

727 311 021 727 311 051 10.0 250 Flow -X2

PPMTE100 727 311 022 727 311 052 10.0 250 Flow -X2

PPMTE120 727 311 023 727 311 053 12.0 300 Flow -X2

Page 93: GF Piping Systems worldwide at home

93

Tee

Type 310, PROGEF Standard, PP-H for Socket Fusion, metric

PNd [mm]

D [mm]

Z [mm]

L [mm]

L1 [mm]

H [mm]

10 20 48 50 128 90 76

10 25 58 55 142 100 78

10 32 65 60 156 110 81

10 40 79 60 160 110 85

10 50 91 65 176 120 89

10 63 105 70 194 130 95

• Threaded outlet 1¼ inch NPSM• Union end with fusion socket PP-H

PP

272X

515

2537

2536

2551

Wafer

Type 311, PP-H, Wafer fitting, metric and inch

PNd [mm]

D [mm]

H[mm]

L[mm]

L1 [mm]

16 75 88 133 48 61

16 90 102 140 48 69

16 110 132 145 48 79

16 125 132 144 48 79

16 140 157 149 48 94

16 160 182 156 48 106

16 180 182 163 48 106

16 200 236 170 48 134

16 225 236 178 48 134

16 250 289 263 48 160

16 280 289 273 48 160

16 315 329 285 48 185

d

G

• Threaded outlet 1¼ NPSM• Suitable for backing flanges metric and inch• Suitable for SDR 11 - SDR 17.6• Delivered with profile O-ring• Wafer can be used with other pipe materials

Page 94: GF Piping Systems worldwide at home

94

PVDF

Flow and pH

• For use with P51530-X1, 3-2536-X1, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX

Type 311, SYGEF Standard, metric and inch

Part No. FPM Code No.d [in.]

DN [mm]

Sensor Type

SFMTF025 735 311 042 2.50 65 Flow -X1

SFMTF030 735 311 043 3.00 80 Flow -X1

SFMTF040 735 311 044 4.00 100 Flow -X1

735 311 045 4.00 100 Flow -X1

SFMTF050 735 311 046 5.00 125 Flow -X1

SFMTF060 735 311 047 6.00 150 Flow -X1

735 310 049 8.00 200 Flow -X1

SFMTF080 735 311 050 8.00 200 Flow -X1

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Type 310, SYGEF Standard, PVDF, metric

Part No. FPM Code No.DN [mm]

Sensor Type

SFMT005 735 310 036 15 Flow -X0, pH -XX

SFMT007 735 310 037 20 Flow -X0, pH -XX

SFMT010 735 310 038 25 Flow -X0, pH -XX

SFMT012 735 310 039 32 Flow -X0, pH -XX

SFMT015 735 310 040 40 Flow -X0, pH -XX

SFMT020 735 310 041 50 Flow -X0, pH -XX

Page 95: GF Piping Systems worldwide at home

95

Type 311, SYGEF Standard, metric and inch

PNd [mm]

H [mm]

D [mm]

L [mm]

L1 [mm]

10/16 75 135 88 48 61

10/16 90 141 102 48 69

10/16 110 148 132 48 79

10/16 125 147 132 48 79

10/16 140 153 157 48 94

10/16 160 161 482 48 106

10/16 200 175 236 48 134

10/16 225 185 236 48 134

d

G

• Threaded outlet 1¼ inch NPSM• Suitable for backing flanges metric and inch• Delevered with profile O-ring• Wafer can be used with other pipe materials

Tee

• Socket fusion equipment is required to install PVDF union tees• FPM O-rings

Type 310, SYGEF Standard, PVDF, metric

PNd [mm]

D [mm]

Z [mm]

L [mm]

L1 [mm]

H [mm]

16 20 45 50 128 90 76

16 25 55 55 142 100 78

16 32 62 60 156 110 81

16 40 75 60 160 110 85

16 50 84 65 176 120 89

16 63 101 70 194 130 95

Wafer

PVD

F

272X

515

2537

2536

2551

Page 96: GF Piping Systems worldwide at home

96

Fiberglass

Flow and pH

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Fiberglass Glue-on Tees

Part No. Code No. Size [in.] Sensor Type

FPT015 159 000 446 1.50 Flow -X0, pH -XX

FPT020 159 000 447 2.00 Flow -X0, pH -XX

Fiberglass Glue-on Saddles

Part No. Code No. Size [in.] Sensor Type

FPS030 159 000 441 3.00 Flow -X0, pH -XX

FPS040 159 000 442 4.00 Flow -X0, pH -XX

FPS060 159 000 443 6.00 Flow -X1

FPS080 198 801 417 8.00 Flow -X1

FPS0100 159 000 444 10.00 Flow -X2

FPS0120 159 000 445 12.00 Flow -X2

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Page 97: GF Piping Systems worldwide at home

97

• PVDF insert - all sizes• PTFE wetted material. Contact factory for available options

Fiberglass Glue-on Tees

L [in.] H [in.] i.d. [in.]

5.5 4.7 1.92

7.7 8.0 2.38

Fiberglass Glue-on Saddles

L [in.] H [in.] o.d. [in.] C [in.]

5.9 4.5 3.50 1.44

8.0 4.5 4.50 1.44

8.0 6.5 6.62 2.25

10.0 8.0 8.62 2.25

12.0 8.5 10.75 2.25

12.0 8.5 12.75 2.25

Saddle

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC• Mounts on fiberglass pipe• PTFE wetted material. Contact factory for available options.• Custom sizes available

H

L

i.d.

H C

L

Tee

Fibe

r-gl

ass

272X

515

2537

2536

2551

Page 98: GF Piping Systems worldwide at home

98

Metals

Flow and pH

Carbon Steel Threaded Tees with NPT Threads

Part No. Code No. Size [in.] Sensor Type

CS4T005 198 801 459 0.50 Flow -X0, pH -XX

CS4T007 198 801 460 0.75 Flow -X0, pH -XX

CS4T010 198 801 461 1.00 Flow -X0, pH -XX

CS4T012 198 801 462 1.25 Flow -X0, pH -XX

CS4T015 198 801 419 1.50 Flow -X0, pH -XX

CS4T020 198 801 463 2.00 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Copper Sweat-on Tee with PVDF insert

Part No. Code No. Size [in.] Sensor Type

CUKT005 198 801 687 0.50 Flow -X0, pH -XX

CUKT007 198 801 688 0.75 Flow -X0, pH -XX

CUKT010 198 801 689 1.00 Flow -X0, pH -XX

CUKT012 198 801 690 1.25 Flow -X0, pH -XX

CUKT015 198 801 691 1.50 Flow -X0, pH -XX

CUKT020 198 801 418 2.00 Flow -X0, pH -XX

Galvanized Iron Threaded Tee with NPT Threads and PVDF insert

Part No. Code No. Size [in.] Sensor Type

IR4T010 198 801 421 1.00 Flow -X0, pH -XX

IR4T012 198 801 422 1.25 Flow -X0, pH -XX

IR4T015 198 801 423 1.50 Flow -X0, pH -XX

IR4T020 198 801 424 2.00 Flow -X0, pH -XX

Page 99: GF Piping Systems worldwide at home

99

H

LNPT

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

• No insert up to 1 in., over 1 in. - PVDF insert• For use with copper pipe (SCH K)• PTFE wetted material. Contact factory for available options.

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

Carbon Steel Threaded Tees with NPT Threads

L [in.] H [in.]

3.6 4.0

3.6 4.2

3.6 4.2

3.8 4.5

4.1 4.8

4.9 5.3

Copper Sweat-on Tee with PVDF insert

L [in.] H [in.] i.d. [in.]

3.15 3.57 0.62

2.96 3.52 0.87

3.23 3.80 1.12

4.16 4.12 1.38

4.43 4.34 1.63

5.31 4.86 2.11

Galvanized Iron Threaded Tee with NPT Threads and PVDF insert

NPT L [in.] H [in.]

1.00 3.4 4.1

1.25 3.56 4.34

1.50 3.75 4.67

2.00 3.90 5.05

Tee

Met

als272X

515

2537

2536

2551

Page 100: GF Piping Systems worldwide at home

100

Metals

Flow and pH

316 SS (1.4401) Threaded Tees with NPT Threads with PVDF insert

Part No. Code No. Size [in.] Sensor Type

CR4T005 198 801 554 0.50 Flow -X0, pH -XX

CR4T007 198 801 555 0.75 Flow -X0, pH -XX

CR4T010 198 801 556 1.00 Flow -X0, pH -XX

CR4T012 198 801 783 1.25 Flow -X0, pH -XX

CR4T015 198 801 784 1.50 Flow -X0, pH -XX

CR4T020 198 801 785 2.00 Flow -X0, pH -XX

Brass Threaded Tee with NPT Threads and PVDF insert

Part No. Code No. Size [in.] Sensor Type

BR4T010 198 801 770 1.00 Flow -X0, pH -XX

BR4T012 198 801 771 1.25 Flow -X0, pH -XX

BR4T015 198 801 772 1.50 Flow -X0, pH -XX

BR4T020 198 801 773 2.00 Flow -X0, pH -XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Page 101: GF Piping Systems worldwide at home

101

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

• PVDF insert - all sizes• For use with SCH 40 metal pipe (ASTM)• PTFE wetted material. Contact factory for available options.

Brass Threaded Tee with NPT Threads and PVDF insert

NPT [in.] L [in.] H [in.]

1.00 3.36 4.09

1.25 3.42 4.42

1.50 3.46 4.70

2.00 3.68 5.19

316 SS (1.4401) Threaded Tees with NPT Threads with PVDF insert

L [in.] H [in.]

3.6 4.0

3.6 4.2

3.6 4.2

3.8 4.5

4.1 4.8

4.9 5.3

H

LNPT

Tee

Met

als272X

515

2537

2536

2551

Page 102: GF Piping Systems worldwide at home

102

Metals

Flow and pH

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Brass Brazolet with PVDF insert for use with copper pipe (SCH 40 ASTM)

Part No. Code No. Size [in.] Sensor Type

BR4B025 198 801 794 2.50 Flow -X0, pH-XX

BR4B030 198 801 795 3.00 Flow -X0, pH -XX

BR4B040 198 801 796 4.00 Flow -X0, pH -XX

BR4B050 198 801 797 5.00 Flow -X1

BR4B060 198 801 798 6.00 Flow -X1

BR4B080 198 801 799 8.00 Flow -X1

BR4B100 198 801 800 10.0 Flow -X2

BR4B120 198 801 801 12.0 Flow -X2

Carbon Steel Weld-on Weldolets for use with SCH 40 metal pipe (ASTM)

Part No. Code No. Size [in.] Sensor Type

CS4W025 198 801 464 2.50 Flow -X0, pH-XX

CS4W030 198 801 557 3.00 Flow -X0, pH -XX

CS4W040 198 801 552 4.00 Flow -X0, pH -XX

CS4W050 198 801 465 5.00 Flow -X1

CS4W060 198 801 553 6.00 Flow -X1

CS4W080 198 801 574 8.00 Flow -X1

CS4W100 198 801 575 10.0 Flow -X2

CS4W120 198 801 576 12.0 Flow -X2

Page 103: GF Piping Systems worldwide at home

103

Brass Brazolet with PVDF insert for use with cop-per pipe (SCH 40 ASTM)

W [in.] H [in.] C [in.]

2.50 2.48 1.31

2.50 2.47 1.31

2.50 2.45 1.31

3.50 3.24 2.10

3.50 3.11 2.10

3.50 2.88 2.10

3.50 5.63 2.10

3.50 5.40 2.10

Carbon Steel Weld-on Weldolets for use with SCH 40 metal pipe (ASTM)

W [in.] H [in.] C [in.]

2.60 2.48 1.31

2.60 2.47 1.31

2.60 2.45 1.31

3.50 3.24 2.10

3.50 3.11 2.10

3.50 2.88 2.10

3.50 5.63 2.10

3.50 5.40 2.10

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• PTFE wetted material. Contact factory for available options.

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• PTFE wetted material. Contact factory for available options.

Tee

Met

als272X

515

2537

2536

2551

Page 104: GF Piping Systems worldwide at home

104

Metals

Flow and pH

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Iron Strap-on Saddle for use with SCH 80 metal pipe (ASTM)

Part No. Code No. Size [in.] Sensor Type

IR8S020 198 801 425 2.00 Flow -X0, pH -XX

IR8S025 198 801 426 2.50 Flow -X0, pH -XX

IR8S030 198 801 427 3.00 Flow -X0, pH -XX

IR8S040 198 801 420 4.00 Flow -X0, pH -XX

IR8S050 198 801 429 5.00 Flow -X1

IR8S060 198 801 430 6.00 Flow -X1

IR8S080 198 801 431 8.00 Flow -X1

IR8S100 198 801 432 10.0 Flow -X2

IR8S120 198 801 433 12.0 Flow -X2

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

316 SS (1.4401) Weldolets with PVDF insert for use with SCH 40 metal pipe (ASTM)

Part No. Code No. Size [in.] Sensor Type

CR4W025 198 801 786 2.50 Flow -X0, pH -XX

CR4W030 198 801 787 3.00 Flow -X0, pH -XX

CR4W040 198 801 788 4.00 Flow -X0, pH -XX

CR4W050 198 801 789 5.00 Flow -X1

CR4W060 198 801 790 6.00 Flow -X1

CR4W080 198 801 791 8.00 Flow -X1

CR4W100 198 801 792 10.0 Flow -X2

CR4W120 198 801 793 12.0 Flow -X2

Page 105: GF Piping Systems worldwide at home

105

• C - Clearance dimension• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• Buna-N O-ring• Larger sizes may be available and PTFE wetted material. Contact factory.

Iron Strap-on Saddle for use with SCH 80 metal pipe (ASTM)

H [in.]

o.d. min [in.]

o.d. max [in.]

C [in.]

5.5 2.35 2.56 1.44

5.5 2.44 2.91 1.44

6.5 2.97 3.54 1.44

7.5 3.74 4.55 2.25

9.0 4.74 5.63 2.25

10.5 5.94 6.70 2.25

12.0 7.69 8.72 2.25

18.0 10.64 12.12 2.25

20.0 12.62 14.32 2.25

• Up to 8 in. - PVDF insert, over 8 in. - PVC insert• C - Clearance dimension• PTFE wetted material. Contact factory for available options.

316 SS (1.4401) Weldolets with PVDF insert for use with SCH 40 metal pipe (ASTM)

W [in.] H [in.] C [in.]

2.50 2.48 1.31

2.50 2.47 1.31

2.50 2.45 1.31

3.50 3.24 2.10

3.50 3.11 2.10

3.50 2.88 2.10

3.50 5.63 2.10

3.50 5.40 2.10

Tee

Saddle

Met

als272X

515

2537

2536

2551

Page 106: GF Piping Systems worldwide at home

106

• For use with P525-3 and P525-3S only

Metals

Flow and pH

• For use with P525-1 and P525-1S only

Metalex Socket Weld Mini-Tap (1.4401)

Part No. Code No. DN [mm] Size [in.] Sensor Type

P526-2005 198 840 501 15 0.50 P525-1, -1S

P526-2007 198 840 502 20 0.75 P525-1, -1S

P526-2010 198 840 503 25 1.00 P525-1, -1S

• For use with P525-2 and P525-2S only

Metalex Weld-on Mini-Tap (1.4401)

Part No. Code No. Size [in.] Sensor Type

P526-2012 159 000 494 1.25 P525-2, -2S

P526-2015 198 840 506 1.50 P525-2, -2S

P526-2020 159 000 495 2.00 P525-2, -2S

P526-2025 159 000 496 2.50 P525-2, -2S

P526-2030 159 000 497 3.00 P525-2, -2S

P526-2040 159 000 498 4.00 P525-2, -2S

P526-2050 159 000 499 5.00 P525-2, -2S

P526-2060 159 000 500 6.00 P525-2, -2S

P526-2080 159 000 501 8.00 P525-2, -2S

P526-2100 159 000 502 10.00 P525-2, -2S

P526-2120 159 000 503 12.00 P525-2, -2S

Metalex Strap-on Saddle (1.4401)

Part No. Code No. Size [in.] Sensor Type

P526-1020 159 000 484 2.00 P525-3, -3S

P526-1025 159 000 485 2.50 P525-3, -3S

P526-1030 159 000 486 3.00 P525-3, -3S

P526-1040 159 000 487 4.00 P525-3, -3S

P526-1050 159 000 488 5.00 P525-3, -3S

P526-1060 159 000 489 6.00 P525-3, -3S

P526-1080 159 000 490 8.00 P525-3, -3S

P526-1100 159 000 491 10.00 P525-3, -3S

P526-1120 159 000 492 12.00 P525-3, -3S

Page 107: GF Piping Systems worldwide at home

107

525

• For use with SS pipe

Metalex Socket Weld Mini-Tap (1.4401)D [mm]

H [mm]

L [in.]

W [in.]

H [in.]

i.d. [in.]

21.8 8.4 2.0 2.4 3.0 0.85

27.2 12.7 2.0 2.4 3.0 1.06

33.9 12.7 2.0 2.4 3.0 1.325

• For use with SS pipe• Gasket Klinger C4401 Thermoseal

Metalex Weld-on Mini-Tap (1.4401)

W [in.] H [in.] C [in.]

1.66 2.25 1.26

1.66 2.20 1.26

1.66 2.17 1.26

1.66 2.10 1.26

1.66 2.00 1.26

1.66 1.95 1.26

1.66 1.83 1.26

1.66 1.75 1.26

1.66 1.56 1.26

1.66 1.35 1.26

1.66 1.15 1.26

Metalex Strap-on Saddle (1.4401)W [in.]

H [in.]

o.d. min [in.]

o.d. max [in.]

5.5 7.0 2.35 2.56

5.5 7.0 2.44 2.91

6.0 7.5 2.97 3.54

7.0 8.0 3.74 4.55

8.0 10.0 4.74 5.63

9.5 10.5 5.94 6.70

12.0 12.75 7.69 8.72

15.0 14.5 10.64 12.12

17.0 17.0 12.62 14.32

• For use with SS pipe

W

H

o.d.

H

CW

Weld-on mini-tap

75D

DN

H

61

49

i.d.H

W

L

Met

als

Page 108: GF Piping Systems worldwide at home

108

MetalsFlow and pH

• Ready to install, studs and nuts in one package• These fittings are only available from your local Georg Fischer sales office

Multi/Saddle Plus Spatula for use with Iron Multi/Saddle Plus 201

Code No. Description

709 613 904 Spatula for saddle outlet 1¼

709 613 905 Spatula for saddle outlet 1½ / d40 + d50

• These fittings are only available from your local Georg Fischer sales office

Multi/Saddle Straps for use with Iron Multi/Saddle Plus 201

Code No. Strap Range [in.] DN min [mm]

DN max [mm]

709 613 930 2.375 3.25 60 80

709 613 932 2.75 3.625 70 90

709 613 934 3.625 4.375 90 110

709 613 936 4.375 5.25 110 130

709 613 938 5.25 6.00 130 150

709 613 940 5.75 6.625 145 165

709 613 942 6.375 7.25 160 180

709 613 944 7.00 7.75 175 195

709 613 946 7.625 8.375 190 210

709 613 948 8.25 9.00 205 225

709 613 950 8.75 9.625 220 240

709 613 952 9.375 10.25 235 255

709 613 954 10.00 10.75 250 270

709 613 956 10.75 11.625 270 290

709 613 958 11.375 12.25 285 305

709 613 960 12.00 12.75 300 320

709 613 962 12.625 13.375 315 335

709 613 964 13.375 14.25 335 355

• For use with 3-2552-2X/-3X, 3-2540-XX, 3-3719-11 Wet-Tap assembly with the 3-275X-WTX Wet-Tap electrode• Do not use these fittings for PE pipes• 1½ and 2 inch saddles must be applied for pipes DN80 or larger

Iron Multi/Saddle Plus 201

EPDM Code NBR Code Inch PN Water

PNGas Sensor Type

709 613 736 709 613 836 1.25 16.0 5.0 2552-2

709 613 738 709 613 838 1.50 16.0 5.0 2552-3, 2540-XX, 3719-11

Page 109: GF Piping Systems worldwide at home

109

3719

2552

2540

Multi/Saddle

Met

als

Page 110: GF Piping Systems worldwide at home

110

ElectrofusionFlow and pH

Electrofusion for PE pipes: Transition Saddles with Stainless 1¼ inch Outlet

Part No. Size [in.] Sensor Type

10004673 2.0 2552-1

10004686 3.0 2552-1

10004700 4.0 2552-1

10004717 6.0 2552-1

10004740 8.0 2552-1

Special request 10.0 2552-1 or -2

Special request 12.0 2552-1 or -2

1½ inch outlet

10004676 2.0 2552-3, 2540-XX, 3719-11

10004689 3.0 2552-3, 2540-XX, 3719-11

10004703 4.0 2552-3, 2540-XX, 3719-11

10004720 6.0 2552-3, 2540-XX, 3719-11

10004743 8.0 2552-3, 2540-XX, 3719-11

Special request 10.0 2552-3, 2540-XX, 3719-11

Special request 12.0 2552-3, 2540-XX, 3719-11

• Transition saddle with 1¼ FNPT branch/outlet• Transition saddle with 1½ FNPT branch/outlet• These fittings are only available from your local Georg Fischer sales office

Page 111: GF Piping Systems worldwide at home

111

3719

2552

2540

Electrofusion

Electrofusion for PE pipes: Transition Saddles with Stainless Outlet

L [in.] H [in.] d [in.]

3.6 3.18 N/A

4.6 3.18 N/A

6.26 3.8 N/A

8.68 4.96 N/A

5.92 2.96 N/A

Call Call N/A

Call Call N/A

3.6 3.18 N/A

4.6 3.18 N/A

6.26 3.8 N/A

8.68 4.96 N/A

5.92 2.96 N/A

Call Call N/A

Call Call N/A

Elec

tro-

Fusi

on

Page 112: GF Piping Systems worldwide at home

112

K-Factors

- K-Factors must be considered as approximate values

- The number of pulses per volumetric unit may vary depending on the medium and the installation

- For optimum performance, the system must be calibrated after installation

- Please contact VG Japan for JIS K-Factors

- Further information can be found on www.georgfischer.com or in the Georg Fischer Planning Fundamentals

Page 113: GF Piping Systems worldwide at home

113

K-Fa

ctor

s

K-Factors for Type 310, PVC-U for Socket Systems metric

Type 310 K-Factors

Code No. Code No. d DN Sensor 515/8510 2536/8512/2537 2551EPDM FPM [mm] [mm] Type pulse/litre pulse/litre pulse/litre721 310 006 721 310 036 20 15 Flow -X0 128.45 256.90 546.3721 310 007 721 310 037 25 20 Flow -X0 64.16 128.32 300.29721 310 008 721 310 038 32 25 Flow -X0 39.27 78.54 189.31721 310 009 721 310 039 40 32 Flow -X0 22.49 44.98 117.85721 310 010 721 310 040 50 40 Flow -X0 13.70 27.40 73.67721 310 011 721 310 041 63 50 Flow -X0 7.86 15.72 42.1

K-Factors for Type 312, PVC-U Clamp-on Saddle, metric

Type 312 SDR 21 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551[mm] [mm] Type pulse/litre pulse/litre pulse/litre

* 198 150 538 75 65 Flow -X0 4.757 9.787 23.729198 150 539 90 80 Flow -X0 3.525 7.281 17.715

* 198 150 540 110 100 Flow -X0 2.328 4.806 11.743* 198 150 543 160 150 Flow -X1 1.165 2.394 5.882

198 150 545 225 200 Flow -X1 0.554 1.141 2.845

Type 312 SDR 13.6 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551[mm] [mm] Type pulse/litre pulse/litre pulse/litre

198 150 538 75 65 Flow -X0 5.026 10.154 24.370198 150 539 90 80 Flow -X0 3.800 7.833 19.071198 150 540 110 100 Flow -X0 2.642 5.454 13.320198 150 543 160 150 Flow -X1 1.261 2.600 6.401

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX

* These K-Factors were derived from a formula. To obtain optimal K-Factors, you must calibrate the system.• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX

Page 114: GF Piping Systems worldwide at home

114

K-Factors for Type 312, PVC-U, Glue-on Saddle, metric

Type 312 SDR 21 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551[mm] [mm] Type pulse/litre pulse/litre pulse/litre

* 721 312 012 75 65 Flow -X1 5.479 11.238 27.196721 312 013 90 80 Flow -X1 3.582 7.394 17.978

* 721 312 014 110 100 Flow -X1 2.267 4.671 11.419

* 721 312 015 125 100 Flow -X1 1.932 3.969 9.690* 721 312 016 140 125 Flow -X1 1.526 3.137 7.681* 721 312 017 160 150 Flow -X1 1.165 2.394 5.882* 721 312 019 200 150 Flow -X1 0.740 1.520 3.762* 721 312 020 225 200 Flow -X2 0.582 1.196 2.973* 721 312 021 250 200 Flow -X2 0.469 0.963 2.403* 721 312 023 315 300 Flow -X2 0.292 0.599 1.513

Type 312 SDR 13.6 K-FactorsCode No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre721 312 012 75 65 Flow -X1 5.966 12.297 29.791

* 721 312 013 90 80 Flow -X1 3.854 7.953 19.365* 721 312 014 110 100 Flow -X1 2.402 4.895 11.942

721 312 015 125 100 Flow -X1 2.094 4.317 10.557721 312 016 140 125 Flow -X1 1.671 3.446 8.457721 312 017 160 150 Flow -X1 1.261 2.600 6.401

K-Factors for Type 310, PROGEF Standard, PP-H for Socket Fusion, metric

Type 310 K-Factors

Code No. Code No. d DN Sensor 515/8510 2536/8512/2537 2551

EPDM FPM [mm] [mm] Type pulse/litre pulse/litre pulse/litre

727 310 006 727 310 036 20 15 Flow -X0 127.23 251.75 579.32

727 310 007 727 310 037 25 20 Flow -X0 73.21 148.77 350.81

727 310 008 727 310 038 32 25 Flow -X0 37.30 77.04 194.76

727 310 009 727 310 039 40 32 Flow -X0 22.07 44.71 119.81

727 310 010 727 310 040 50 40 Flow -X0 13.54 27.45 72.66

727 310 011 727 310 041 63 50 Flow -X0 7.82 16.06 41.45

* These K-Factors were derived from a formula. To obtain optimal K-Factors, you must calibrate the system.• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX

Page 115: GF Piping Systems worldwide at home

115

K-Fa

ctor

s

K-Factors for Type 311, PROGEF Standard, PP-H, Wafer fitting, metric

Type 311 K-Factors

Code No. Code No. d DN Sensor 515/8510 2536/8512/2537 2551

EPDM FPM [mm] [mm] Type pulse/litre pulse/litre pulse/litre

727 311 012 727 311 042 75 65 Flow -X1 5.69 11.76 28.54

727 311 013 727 311 043 90 80 Flow -X1 3.65 7.49 18.20

727 311 014 727 311 044 110 100 Flow -X1 2.31 4.64 11.25

727 311 015 727 311 045 125 100 Flow -X1 2.06 4.26 10.43

727 311 016 727 311 046 140 125 Flow -X1 1.64 3.39 8.31

727 311 017 727 311 047 160 150 Flow -X1 1.25 2.59 6.37

727 311 018 727 311 048 180 150 Flow -X1 0.99 2.03 5.03

727 311 019 727 311 049 200 200 Flow -X1 0.80 1.64 4.07

727 311 020 727 311 050 225 200 Flow -X1 0.63 1.29 3.22

727 311 021 727 311 051 250 250 Flow -X2 0.51 1.04 2.61

727 311 022 727 311 052 280 250 Flow -X2 0.40 0.83 2.08

727 311 023 727 311 053 315 300 Flow -X2 0.32 0.65 1.64

• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX/X2-XX

K-Factors for PP-H Installation Fittings Type 312

Type 312 SDR 11 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551 [mm] [mm] Type pulse/litre pulse/litre pulse/litre

* 727 312 072 75 65 Flow -X1 6.54 13.46 32.59727 312 073 90 80 Flow -X1 4.26 8.80 21.42

* 727 312 074 110 100 Flow -X1 2.68 5.49 13.43* 727 312 075 125 100 Flow -X1 2.33 4.80 11.73* 727 312 076 140 125 Flow -X1 1.85 3.80 9.31

727 312 077 160 150 Flow -X1 1.40 2.89 7.10* 727 312 078 180 150 Flow -X2 1.11 2.29 5.65

727 312 079 200 200 Flow -X2 0.88 1.81 4.47727 312 080 225 200 Flow -X2 0.70 1.45 3.60727 312 081 250 250 Flow -X2 0.57 1.16 2.91727 312 082 280 250 Flow -X2 0.44 0.91 2.29727 312 083 315 300 Flow -X2 0.35 0.72 1.82

* These K-Factors were derived from a formula. To obtain optimal K-Factors, you must calibrate the system.• For use with P51530-X1/-X2, 3-2536-X1/-X2, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX

Page 116: GF Piping Systems worldwide at home

116

K-Factors for Type 318, PROGEF Standard, PP-H for Butt Fusion, metric

Type 318 K-Factors

Code No. Code No. d DN Sensor 515/8510 2536/8512/2537 2551

EPDM FPM [mm] [mm] Type pulse/litre pulse/litre pulse/litre

727 318 006 727 318 036 20 15 Flow -X0 127.23 251.75 579.32

727 318 007 727 318 037 25 20 Flow -X0 73.21 148.77 350.81

727 318 008 727 318 038 32 25 Flow -X0 37.30 77.04 194.76

727 318 009 727 318 039 40 32 Flow -X0 22.07 44.71 119.81

727 318 010 727 318 040 50 40 Flow -X0 13.54 27.45 72.66

727 318 011 727 318 041 63 50 Flow -X0 7.82 16.06 41.45

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-X0, 3-2551-X0

K-Factors for Type 310, SYGEF Standard for Socket Fusion, metric

Type 310 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

735 310 036 20 15 Flow -X0 111.19 218.56 514.26

735 310 037 25 20 Flow -X0 60.28 129.42 305.96

735 310 038 32 25 Flow -X0 36.12 74.92 197.91

735 310 039 40 32 Flow -X0 20.95 41.90 116.12

735 310 040 50 40 Flow -X0 11.49 22.98 65.77

735 310 041 63 50 Flow -X0 6.85 13.31 38.80

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX

Page 117: GF Piping Systems worldwide at home

117

K-Fa

ctor

s

K-Factors for SYGEF Standard, Type 311 metric and inch

Type 311 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

735 311 042 75 65 Flow -X1 5.25 10.84 26.33

735 311 043 90 80 Flow -X1 3.51 7.18 17.43

735 311 044 110 100 Flow -X1 2.00 3.99 9.65

735 311 045 125 100 Flow -X1 1.82 3.75 9.18

735 311 046 140 125 Flow -X1 1.44 2.97 7.30

735 311 047 160 150 Flow -X1 1.07 2.21 5.44

735 311 049 200 200 Flow -X1 0.68 1.41 3.49

735 311 050 225 200 Flow -X1 0.54 1.10 2.75

• For use with P51530-X1, 3-2536-X1, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX

K-Factors for Type 318 SYGEF Standard for Butt fusion, metric

Type 318 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

735 318 036 20 15 Flow -X0 111.19 218.56 514.26

735 318 037 25 20 Flow -X0 60.28 129.42 305.96

735 318 038 32 25 Flow -X0 36.12 74.92 197.91

735 318 039 40 32 Flow -X0 20.95 41.90 116.12

735 318 040 50 40 Flow -X0 11.49 22.98 65.77

735 318 041 63 50 Flow -X0 6.85 13.31 38.80

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX

Page 118: GF Piping Systems worldwide at home

118

K-Factors for Type 310, ABS, metric

Type 310 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

729 310 007 25 20 Flow -X0 82.12 159.41 337.47

729 310 008 32 25 Flow -X0 42.00 80.05 192.00

729 310 009 40 32 Flow -X0 23.38 43.33 121.26

729 310 010 50 40 Flow -X0 14.08 26.89 70.31

729 310 011 63 50 Flow -X0 7.86 15.76 40.69

K-Factors for Type 312, ABS Glue-on, metric

Type 312 K-Factors

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

729 312 012 75 65 Flow -X1 5.58 11.27 27.57

* 729 312 013 90 80 Flow -X1 3.48 7.14 17.38

* 729 312 014 110 100 Flow -X1 2.29 4.40 10.81

729 312 016 140 125 Flow -X1 1.61 3.19 7.94

729 312 017 160 150 Flow -X1 1.24 2.45 6.12

729 312 019 200 200 Flow -X1 0.78 1.53 3.87

729 312 020 225 200 Flow -X1 0.63 1.22 3.10

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX,

* These K-Factors were derived from a formula. To obtain optimal K-Factors, you must calibrate the system.• For use with P51530-X1, 3-2536-X1, 3-8510-X1, 3-8512-X1, 3-2537-XC-X1, 3-2551-X1-XX

Page 119: GF Piping Systems worldwide at home

119

K-Fa

ctor

s

K-Factors for Stainless Steel Installation Fittings Type 314

Type 314 K-FactorsCode No. d emin emax Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] [mm] Type pulse/litre pulse/litre pulse/litre724 314 000 70.00 2.00 3.00 X0 5.59 11.55 27.98724 314 000 70.00 3.00 5.00 X0 6.14 12.69 30.76724 314 000 70.00 5.00 7.00 X0 7.02 14.50 35.15724 314 000 73.03 5.00 7.00 X0 6.34 13.09 31.74724 314 000 73.03 7.00 9.00 X0 7.26 14.99 36.35724 314 000 73.03 9.00 11.00 X0 8.39 17.34 42.04724 314 000 76.10 2.00 4.00 X0 4.80 9.92 24.06724 314 000 76.10 4.00 6.00 X0 5.40 11.15 27.06724 314 000 76.10 6.00 8.00 X0 6.12 12.64 30.66724 314 000 80.00 2.00 4.00 X0 4.31 8.89 21.59724 314 000 80.00 4.00 6.00 X0 4.81 9.94 24.13724 314 000 88.90 2.00 3.00 X0 3.34 6.91 16.80724 314 000 101.60 2.00 3.00 X0 2.52 5.20 12.67724 314 000 101.60 3.00 4.00 X0 2.63 5.42 13.21724 314 000 104.00 2.00 3.00 X0 2.40 4.95 12.07724 314 000 104.00 3.00 4.00 X0 2.50 5.15 12.57724 314 000 108.00 2.00 3.00 X0 2.21 4.57 11.15724 314 000 108.00 3.00 4.00 X0 2.30 4.75 11.59724 314 000 114.30 2.00 3.00 X0 1.96 4.05 9.90724 314 000 114.30 3.00 4.00 X0 2.04 4.20 10.27724 314 000 114.30 4.00 5.00 X0 2.12 4.37 10.67724 314 000 129.00 2.00 3.00 X0 1.52 3.14 7.69724 314 000 129.00 3.00 4.00 X0 1.57 3.24 7.95724 314 000 139.70 2.00 3.00 X0 1.29 2.66 6.52724 314 000 139.70 3.00 4.00 X0 1.33 2.74 6.72724 314 000 139.70 4.00 5.00 X0 1.37 2.82 6.92724 314 000 154.00 2.00 3.00 X0 1.05 2.17 5.33724 314 000 154.00 3.00 4.00 X0 1.08 2.22 5.47724 314 000 168.30 2.00 3.00 X0 0.87 1.80 4.44724 314 000 168.30 3.00 4.00 X0 0.89 1.84 4.55724 314 000 168.30 4.00 5.00 X0 0.92 1.89 4.66724 314 001 219.10 2.00 3.00 X1 0.50 1.04 2.58724 314 001 219.10 3.00 4.00 X1 0.51 1.06 2.63724 314 001 219.10 4.00 5.00 X1 0.52 1.08 2.68724 314 001 273.00 2.00 3.00 X1 0.32 0.66 1.65724 314 001 273.00 3.00 4.00 X1 0.32 0.67 1.67724 314 001 273.00 4.00 5.00 X1 0.33 0.68 1.70724 314 001 323.90 3.00 4.00 X1 0.23 0.46 1.18724 314 001 323.90 4.00 5.00 X1 0.23 0.47 1.19724 314 001 323.90 5.00 6.00 X1 0.23 0.48 1.21724 314 001 355.60 2.00 3.00 X1 0.18 0.38 0.96724 314 001 355.60 3.00 4.00 X1 0.19 0.38 0.97724 314 001 355.60 4.00 5.00 X1 0.19 0.39 0.99724 314 002 406.40 2.00 3.00 X2 0.14 0.29 0.74724 314 002 406.40 3.00 4.00 X2 0.14 0.29 0.74724 314 002 406.40 4.00 5.00 X2 0.14 0.29 0.75724 314 002 508.00 2.00 3.00 X2 0.09 0.18 0.47724 314 002 508.00 3.00 4.00 X2 0.09 0.18 0.47724 314 002 609.60 2.00 3.00 X2 0.06 0.12 0.32724 314 002 609.60 3.00 4.00 X2 0.06 0.12 0.33

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX

Page 120: GF Piping Systems worldwide at home

120

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 11; Pipe Series (S) = 5 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 Flow -X0 6.58 13.57 32.88

XXX 314 000 90 80 Flow -X0 4.25 8.76 21.34

XXX 314 000 110 100 Flow -X0 2.66 5.41 13.18

XXX 314 000 125 100 Flow -X0 2.30 4.76 11.64

XXX 314 000 140 125 Flow -X0 1.83 3.77 9.25

XXX 314 000 160 150 Flow -X0 1.36 2.79 6.88

XXX 314 000 180 150 Flow -X0 1.10 2.27 5.60

XXX 314 001 200 200 Flow -X1 0.89 1.83 4.54

XXX 314 001 225 200 Flow -X1 0.70 1.44 3.58

XXX 314 001 250 250 Flow -X1 0.56 1.16 2.90

XXX 314 001 280 250 Flow -X1 0.45 0.92 2.31

XXX 314 001 315 300 Flow -X1 0.35 0.72 1.83

XXX 314 001 355 350 Flow -X1 0.27 0.56 1.44

XXX 314 002 400 400 Flow -X2 0.21 0.44 1.13

XXX 314 002 450 500 Flow -X2 0.17 0.34 0.89

XXX 314 002 500 500 Flow -X2 0.14 0.28 0.72

XXX 314 002 560 600 Flow -X2 0.11 0.22 0.58

XXX 314 002 630 600 Flow -X2 0.08 0.17 0.46

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 17; Pipe Series (S) = 8 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 Flow -X0 5.46 11.28 27.38

XXX 314 000 90 80 Flow -X0 3.55 7.29 17.73

XXX 314 000 110 100 Flow -X0 2.24 4.53 11.01

XXX 314 000 125 100 Flow -X0 1.96 4.05 9.92

XXX 314 000 140 125 Flow -X0 1.56 3.22 7.91

XXX 314 000 160 150 Flow -X0 1.19 2.46 6.05

XXX 314 000 180 150 Flow -X0 0.94 1.93 4.78

XXX 314 000 200 200 Flow -X0 0.76 1.56 3.87

XXX 314 000 225 200 Flow -X0 0.60 1.23 3.06

XXX 314 001 250 250 Flow -X1 0.48 0.99 2.47

XXX 314 001 280 250 Flow -X1 0.38 0.78 1.97

XXX 314 001 315 300 Flow -X1 0.30 0.62 1.56

XXX 314 001 355 350 Flow -X1 0.23 0.48 1.23

XXX 314 001 400 400 Flow -X1 0.18 0.38 0.97

XXX 314 001 450 500 Flow -X1 0.14 0.29 0.76

XXX 314 002 500 500 Flow -X2 0.12 0.24 0.62

XXX 314 002 560 600 Flow -X2 0.09 0.19 0.49

XXX 314 002 630 600 Flow -X2 0.07 0.15 0.39

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX

The first 3 numbers are XXX. These fittings are available in the following materials.

721 --> PVC-U 735 --> PVDF727 --> PP 753 --> PE

Page 121: GF Piping Systems worldwide at home

121

K-Fa

ctor

s

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 21 ; Pipe Series (S) = 10 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 Flow -X0 5.10 10.55 25.61

XXX 314 000 90 80 Flow -X0 3.32 6.80 16.54

XXX 314 000 110 100 Flow -X0 2.11 4.25 10.33

XXX 314 000 125 100 Flow -X0 1.86 3.84 9.39

XXX 314 000 140 125 Flow -X0 1.48 3.05 7.49

XXX 314 000 160 150 Flow -X0 1.13 2.33 5.74

XXX 314 000 180 150 Flow -X0 0.89 1.83 4.52

XXX 314 000 200 200 Flow -X0 0.72 1.48 3.67

XXX 314 000 225 200 Flow -X0 0.56 1.16 2.90

XXX 314 001 250 250 Flow -X1 0.45 0.94 2.34

XXX 314 001 280 250 Flow -X1 0.36 0.74 1.87

XXX 314 001 315 300 Flow -X1 0.28 0.58 1.48

XXX 314 001 355 350 Flow -X1 0.22 0.46 1.16

XXX 314 001 400 400 Flow -X1 0.17 0.36 0.92

XXX 314 001 450 500 Flow -X1 0.14 0.28 0.72

XXX 314 002 500 500 Flow -X2 0.11 0.22 0.59

XXX 314 002 560 600 Flow -X2 0.09 0.18 0.47

XXX 314 002 630 600 Flow -X2 0.07 0.14 0.37

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 33 ; Pipe Series (S) = 16 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 Flow -X0 4.64 9.59 23.27

XXX 314 000 90 80 Flow -X0 3.03 6.20 15.06

XXX 314 000 110 100 Flow -X0 1.93 3.88 9.42

XXX 314 000 125 100 Flow -X0 1.72 3.55 8.70

XXX 314 000 140 125 Flow -X0 1.37 2.82 6.92

XXX 314 000 160 150 Flow -X0 1.04 2.15 5.29

XXX 314 000 180 150 Flow -X0 0.82 1.69 4.18

XXX 314 000 200 200 Flow -X0 0.66 1.37 3.39

XXX 314 000 225 200 Flow -X0 0.52 1.07 2.68

XXX 314 000 250 250 Flow -X0 0.42 0.87 2.17

XXX 314 001 280 250 Flow -X1 0.33 0.69 1.73

XXX 314 001 315 300 Flow -X1 0.26 0.54 1.37

XXX 314 001 355 350 Flow -X1 0.21 0.42 1.08

XXX 314 001 400 400 Flow -X1 0.16 0.33 0.85

XXX 314 001 450 500 Flow -X1 0.13 0.26 0.67

XXX 314 001 500 500 Flow -X1 0.10 0.21 0.54

XXX 314 002 560 600 Flow -X2 0.08 0.16 0.43

XXX 314 002 630 600 Flow -X2 0.06 0.13 0.34

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX

The first 3 numbers are XXX. These fittings are available in the following materials.

721 --> PVC-U 735 --> PVDF727 --> PP 753 --> PE

Page 122: GF Piping Systems worldwide at home

122

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 13.6; Pipe Series (S) = 6.3 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 Flow -X0 5.96 12.30 29.84

XXX 314 000 90 80 Flow -X0 3.85 7.92 19.28

XXX 314 000 110 100 Flow -X0 2.42 4.89 11.92

XXX 314 000 125 100 Flow -X0 2.11 4.35 10.65

XXX 314 000 140 125 Flow -X0 1.68 3.46 8.48

XXX 314 000 160 150 Flow -X0 1.28 2.64 6.49

XXX 314 000 180 150 Flow -X0 1.01 2.08 5.13

XXX 314 000 200 200 Flow -X0 0.81 1.67 4.15

XXX 314 001 225 200 Flow -X1 0.64 1.32 3.28

XXX 314 001 250 250 Flow -X1 0.52 1.06 2.66

XXX 314 001 280 250 Flow -X1 0.41 0.84 2.12

XXX 314 001 315 300 Flow -X1 0.32 0.66 1.67

XXX 314 001 355 350 Flow -X1 0.25 0.52 1.32

XXX 314 001 400 400 Flow -X1 0.20 0.40 1.04

XXX 314 002 450 500 Flow -X2 0.15 0.32 0.82

XXX 314 002 500 500 Flow -X2 0.12 0.25 0.66

XXX 314 002 560 600 Flow -X2 0.10 0.20 0.53

XXX 314 002 630 600 Flow -X2 0.08 0.16 0.42

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 17.6; Pipe Series (S) = 8.3 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 Flow -X0 5.38 11.12 27.00

XXX 314 000 90 80 Flow -X0 3.49 7.16 17.41

XXX 314 000 110 100 Flow -X0 2.21 4.45 10.83

XXX 314 000 125 100 Flow -X0 1.94 4.01 9.81

XXX 314 000 140 125 Flow -X0 1.54 3.19 7.82

XXX 314 000 160 150 Flow -X0 1.18 2.43 5.98

XXX 314 000 180 150 Flow -X0 0.93 1.91 4.72

XXX 314 000 200 200 Flow -X0 0.75 1.54 3.83

XXX 314 000 225 200 Flow -X0 0.59 1.21 3.02

XXX 314 001 250 250 Flow -X1 0.48 0.98 2.45

XXX 314 001 280 250 Flow -X1 0.38 0.77 1.95

XXX 314 001 315 300 Flow -X1 0.30 0.61 1.54

XXX 314 001 355 350 Flow -X1 0.23 0.48 1.21

XXX 314 001 400 400 Flow -X1 0.18 0.37 0.96

XXX 314 001 450 500 Flow -X1 0.14 0.29 0.75

XXX 314 002 500 500 Flow -X2 0.11 0.23 0.61

XXX 314 002 560 600 Flow -X2 0.09 0.18 0.49

XXX 314 002 630 600 Flow -X2 0.07 0.14 0.39

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XXThe first 3 numbers are XXX. These fittings are available in the following materials.

721 --> PVC-U 735 --> PVDF727 --> PP 753 --> PE

Page 123: GF Piping Systems worldwide at home

123

K-Fa

ctor

s

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 26 ; Pipe Series (S) = 12.5 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 Flow -X0 4.83 9.99 24.25

XXX 314 000 90 80 Flow -X0 3.16 6.47 15.72

XXX 314 000 110 100 Flow -X0 2.00 4.03 9.78

XXX 314 000 125 100 Flow -X0 1.78 3.67 8.99

XXX 314 000 140 125 Flow -X0 1.42 2.92 7.17

XXX 314 000 160 150 Flow -X0 1.08 2.23 5.50

XXX 314 000 180 150 Flow -X0 0.85 1.75 4.33

XXX 314 000 200 200 Flow -X0 0.69 1.41 3.51

XXX 314 000 225 200 Flow -X0 0.54 1.11 2.77

XXX 314 000 250 250 Flow -X0 0.44 0.90 2.25

XXX 314 001 280 250 Flow -X1 0.35 0.71 1.79

XXX 314 001 315 300 Flow -X1 0.27 0.56 1.41

XXX 314 001 355 350 Flow -X1 0.21 0.44 1.11

XXX 314 001 400 400 Flow -X1 0.17 0.34 0.877

XXX 314 001 450 500 Flow -X1 0.13 0.26 0.686

XXX 314 001 500 500 Flow -X1 0.10 0.21 0.561

XXX 314 002 560 600 Flow -X2 0.08 0.17 0.447

XXX 314 002 630 600 Flow -X2 0.06 0.13 0.354

K-Factors for plastic weld on Installation Fittings Type 314

Standard Dimension Ratio (SDR) = 41 ; Pipe Series (S) = 20 K-Factor

Code No. d DN Sensor 515/8510 2536/8512/2537 2551

[mm] [mm] Type pulse/litre pulse/litre pulse/litre

XXX 314 000 75 65 – – – –

XXX 314 000 90 80 – – – –

XXX 314 000 110 100 Flow -X0 1.87 3.76 9.11

XXX 314 000 125 100 Flow -X0 1.68 3.46 8.47

XXX 314 000 140 125 Flow -X0 1.33 2.75 6.75

XXX 314 000 160 150 Flow -X0 1.02 2.10 5.16

XXX 314 000 180 150 Flow -X0 0.80 1.65 4.07

XXX 314 000 200 200 Flow -X0 0.64 1.33 3.29

XXX 314 000 225 200 Flow -X0 0.51 1.04 2.60

XXX 314 000 250 250 Flow -X0 0.41 0.84 2.11

XXX 314 000 280 250 Flow -X0 0.32 0.67 1.68

XXX 314 001 315 300 Flow -X1 0.26 0.52 1.33

XXX 314 001 355 350 Flow -X1 0.20 0.41 1.05

XXX 314 001 400 400 Flow -X1 0.16 0.32 0.82

XXX 314 001 450 500 Flow -X1 0.12 0.25 0.65

XXX 314 001 500 500 Flow -X1 0.10 0.20 0.53

XXX 314 001 560 600 Flow -X1 0.08 0.16 0.42

XXX 314 002 630 600 Flow -X2 0.06 0.12 0.33

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XXThe first 3 numbers are XXX. These fittings are available in the following materials.

721 --> PVC-U 735 --> PVDF727 --> PP 753 --> PE

Page 124: GF Piping Systems worldwide at home

124

K-Factor for 2552 Magmeter

Standard Dimension Ratio (SDR) = 11 ; Pipe Series (S) = 5

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552- 212.3 263.1 405.8 34.79 862.43

90 3-2552- 209.6 260.4 403.1 24.22 1238.47

110 3-2552- 206.1 256.9 399.6 16.15 1857.96

125 3-2552- 203.4 254.2 396.9 12.53 2394.04

140 3-2552- 200.8 251.6 394.3 9.95 3013.95

160 3-2552- 197.2 248.0 390.7 7.64 3927.02

180 3-2552- 193.7 244.5 387.2 6.03 4974.41

200 3-2552- 190.2 241.0 383.7 4.88 6145.48

225 3-2552- 185.7 236.5 379.3 3.86 7778.94

250 3-2552- 181.4 232.2 374.9 3.12 9623.73

280 3-2552- 176.1 226.9 369.7 2.48 12077.13

315 3-2552- 169.9 220.7 363.5 1.96 15285.11

355 3-2552- 162.9 213.7 356.4 1.54 19421.25

400 3-2552- 155.0 205.8 348.5 1.22 24658.08

450 3-2552- 146.1 196.9 339.7 0.96 31201.46

500 3-2552- 137.3 188.1 330.9 0.78 38533.02

560 3-2552- 126.8 177.6 320.3 0.62 48372.54

630 3-2552- 114.4 165.2 307.9 0.49 61188.47

Standard Dimension Ratio (SDR) = 17 ; Pipe Series (S) = 8

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552- 214.2 265.0 407.7 29.86 1004.70

90 3-2552- 211.9 262.7 405.5 20.71 1448.25

110 3-2552- 208.9 259.7 402.5 13.84 2166.95

125 3-2552- 206.7 257.5 400.3 10.68 2809.67

140 3-2552- 204.5 255.3 398.0 8.51 3524.23

160 3-2552- 201.5 252.3 395.0 6.51 4604.95

180 3-2552- 198.5 249.3 392.0 5.15 5830.00

200 3-2552- 195.5 246.3 389.0 4.17 7199.36

225 3-2552- 191.7 242.5 385.2 3.29 9107.05

250 3-2552- 188.0 238.8 381.6 2.66 11269.60

280 3-2552- 183.5 234.3 377.1 2.12 14131.50

315 3-2552- 178.3 229.1 371.8 1.68 17883.56

355 3-2552- 172.2 223.0 365.8 1.32 22701.48

400 3-2552- 165.6 216.4 359.1 1.04 28863.36

450 3-2552- 158.1 208.9 351.6 0.82 36539.47

500 3-2552- 150.6 201.4 344.1 0.67 45099.00

560 3-2552- 141.6 192.4 335.1 0.53 56595.27

630 3-2552- 131.1 181.9 324.6 0.42 71612.16

Page 125: GF Piping Systems worldwide at home

125

K-Fa

ctor

s

K-Factor for 2552 Magmeter

Standard Dimension Ratio (SDR) = 21 ; Pipe Series (S) = 10

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552- 214.9 265.7 408.5 28.19 1064.02

90 3-2552- 212.8 263.6 406.4 19.55 1534.47

110 3-2552- 210.0 260.8 403.5 13.10 2290.68

125 3-2552- 207.9 258.7 401.5 10.11 2966.17

140 3-2552- 205.8 256.6 399.4 8.06 3722.90

160 3-2552- 203.0 253.8 396.5 6.17 4858.70

180 3-2552- 200.2 251.0 393.8 4.87 6160.71

200 3-2552- 197.4 248.2 390.9 3.95 7600.17

225 3-2552- 193.9 244.7 387.4 3.12 9623.73

250 3-2552- 190.5 241.3 384.0 2.52 11907.03

280 3-2552- 186.2 237.0 379.7 2.01 14915.30

315 3-2552- 181.4 232.2 374.9 1.59 18910.54

355 3-2552- 175.8 226.6 369.3 1.25 24021.97

400 3-2552- 169.4 220.2 362.9 0.98 30468.43

450 3-2552- 162.4 213.2 356.0 0.78 38590.21

500 3-2552- 155.4 206.2 349.0 0.63 47649.30

560 3-2552- 147.1 197.9 340.6 0.50 59803.57

630 3-2552- 137.3 188.1 330.9 0.40 75722.28

Standard Dimension Ratio (SDR) = 33 ; Pipe Series (S) = 16

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552- 216.0 266.8 409.6 26.06 1151.24

90 3-2552- 214.1 264.9 407.7 18.09 1658.57

110 3-2552- 211.6 262.4 405.1 12.10 2480.31

125 3-2552- 209.7 260.5 403.2 9.37 3203.38

140 3-2552- 207.8 258.6 401.4 7.45 4024.96

160 3-2552- 205.4 256.2 398.9 5.70 5266.15

180 3-2552- 202.8 253.6 396.4 4.50 6665.96

200 3-2552- 200.2 251.0 393.8 3.65 8212.95

225 3-2552- 197.2 248.0 390.7 2.88 10420.52

250 3-2552- 194.0 244.8 387.5 2.33 12857.50

280 3-2552- 190.2 241.0 383.8 1.86 16136.83

315 3-2552- 185.8 236.6 379.4 1.47 20421.44

355 3-2552- 180.8 231.6 374.4 1.16 25955.25

400 3-2552- 175.1 225.9 368.7 0.91 32939.86

450 3-2552- 168.9 219.7 362.5 0.72 41741.55

500 3-2552- 162.6 213.4 356.2 0.58 51540.13

560 3-2552- 155.0 205.8 348.6 0.46 64621.33

630 3-2552- 146.3 197.1 339.8 0.37 81824.55

Page 126: GF Piping Systems worldwide at home

126

K-Factor for 2552 Magmeter

Standard Dimension Ratio (SDR) = 13.6 ; Pipe Series (S) = 6.3

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552- 213.3 264.1 406.8 32.08 935.17

90 3-2552- 210.8 261.6 404.4 22.22 1350.21

110 3-2552- 207.6 258.4 401.2 14.82 2024.74

125 3-2552- 205.2 256.0 398.8 11.46 2617.53

140 3-2552- 202.8 253.6 396.3 9.13 3286.33

160 3-2552- 199.6 250.4 393.1 6.99 4294.16

180 3-2552- 196.3 247.1 389.8 5.53 5429.43

200 3-2552- 193.1 243.9 386.7 4.46 6721.56

225 3-2552- 189.0 239.8 382.6 3.53 8496.90

250 3-2552- 185.0 235.8 378.5 2.86 10499.95

280 3-2552- 180.2 231.0 373.7 2.28 13178.71

315 3-2552- 174.5 225.3 368.0 1.80 16671.48

355 3-2552- 168.0 218.8 361.6 1.42 21191.60

400 3-2552- 160.8 211.6 354.3 1.11 26918.09

450 3-2552- 152.7 203.5 346.2 0.88 34077.16

500 3-2552- 144.6 195.4 338.1 0.71 42079.42

560 3-2552- 134.9 185.7 328.4 0.57 52781.75

630 3-2552- 123.6 174.4 317.1 0.45 66836.41

Standard Dimension Ratio (SDR) = 17.6 ; Pipe Series (S) = 8.3

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552- 214.3 265.1 407.9 29.50 1017.05

90 3-2552- 212.2 263.0 405.7 20.40 1470.50

110 3-2552- 209.2 260.0 402.7 13.67 2194.15

125 3-2552- 207.0 257.8 400.5 10.56 2840.64

140 3-2552- 204.8 255.6 398.3 8.42 3564.68

160 3-2552- 201.8 252.6 395.3 6.44 4657.81

180 3-2552- 198.9 249.7 392.4 5.08 5904.36

200 3-2552- 195.9 246.7 389.4 4.12 7281.96

225 3-2552- 192.2 243.0 385.8 3.25 9227.89

250 3-2552- 188.5 239.3 382.1 2.63 11393.61

280 3-2552- 184.1 234.9 377.7 2.10 14305.14

315 3-2552- 178.9 229.7 372.5 1.66 18104.95

355 3-2552- 173.1 223.9 366.6 1.30 23009.69

400 3-2552- 166.4 217.2 359.9 1.03 29210.76

450 3-2552- 159.0 209.8 352.6 0.81 36986.20

500 3-2552- 151.7 202.5 345.2 0.66 45678.11

560 3-2552- 142.8 193.6 336.4 0.52 57313.50

630 3-2552- 132.5 183.3 326.0 0.41 72524.32

Page 127: GF Piping Systems worldwide at home

127

K-Fa

ctor

s

K-Factor for 2552 Magmeter

Standard Dimension Ratio (SDR) = 26 ; Pipe Series (S) = 12.5

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552- 215.5 266.3 409.1 26.98 1112.05

90 3-2552- 213.5 264.3 407.1 18.75 1599.80

110 3-2552- 210.9 261.7 404.5 12.51 2398.79

125 3-2552- 208.9 259.7 402.5 9.68 3099.83

140 3-2552- 206.9 257.7 400.5 7.72 3884.55

160 3-2552- 204.2 255.0 397.8 5.92 5070.74

180 3-2552- 201.7 252.5 395.2 4.66 6438.08

200 3-2552- 199.0 249.8 392.5 3.78 7942.48

225 3-2552- 195.7 246.5 389.3 2.98 10066.81

250 3-2552- 192.4 243.2 385.9 2.42 12420.94

280 3-2552- 188.5 239.3 382.0 1.92 15598.77

315 3-2552- 183.8 234.6 377.3 1.52 19720.03

355 3-2552- 178.5 229.3 372.1 1.20 25071.41

400 3-2552- 172.6 223.4 366.1 0.94 31839.17

450 3-2552- 166.0 216.8 359.6 0.74 40325.69

500 3-2552- 159.4 210.2 353.0 0.60 49792.02

560 3-2552- 151.5 202.3 345.1 0.48 62467.85

630 3-2552- 142.2 193.0 335.8 0.38 79043.81

Standard Dimension Ratio (SDR) = 41 ; Pipe Series (S) = 20

d Sensor “H Dim-1 Version”

“H Dim-2 Version”

“H Dim-3 Version”

2552K-Factor

Factory set 20 mA

[mm] Type mm mm mm pulse/litre litre/min

75 3-2552-

90 3-2552-

110 3-2552- 212.2 263.0 405.7 11.75 2553.36

125 3-2552- 210.3 261.1 403.9 9.11 3291.89

140 3-2552- 208.5 259.3 402.1 7.26 4130.35

160 3-2552- 206.1 256.9 399.7 5.55 5400.86

180 3-2552- 203.8 254.6 397.3 4.38 6849.51

200 3-2552- 201.4 252.2 394.9 3.55 8461.15

225 3-2552- 198.3 249.1 391.9 2.80 10709.89

250 3-2552- 195.2 246.0 388.8 2.27 13201.01

280 3-2552- 191.7 242.5 385.2 1.81 16583.85

315 3-2552- 187.5 238.3 381.0 1.43 21008.27

355 3-2552- 182.7 233.5 376.2 1.12 26679.70

400 3-2552- 177.2 228.0 370.8 0.89 33880.31

450 3-2552- 171.3 222.1 364.8 0.70 42919.99

500 3-2552- 165.2 216.0 358.7 0.57 52937.99

560 3-2552- 158.0 208.8 351.5 0.45 66460.46

630 3-2552- 149.6 200.4 343.1 0.36 84117.54

Page 128: GF Piping Systems worldwide at home

128

K-Factors for PVC Tees, SCH 80

PVC Tees, SCH 80 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

MPV8T005 159 001 623 0.50 Flow -X0, pH -XX 520.12 1027.1 1027.1 2277.0

MPV8T007 159 001 624 0.75 Flow -X0, pH -XX 297.52 583.19 583.19 1407.6

MPV8T010 159 001 625 1.00 Flow -X0, pH -XX 172.07 335.53 335.53 861.17

MPV8T012 159 001 626 1.25 Flow -X0, pH -XX 91.54 178.79 178.79 464.91

MPV8T015 159 001 627 1.50 Flow -X0, pH -XX 62.22 121.42 121.42 331.43

MPV8T020 159 001 628 2.00 Flow -X0, pH -XX 36.32 71.44 71.44 192.89

K-Factors for CPVC Tees, SCH 80

CPVC Tees, SCH 80 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

MCPV8T005 159 001 641 0.50 Flow -X0, pH -XX 520.12 1027.1 1027.1 2277.0

MCPV8T007 159 001 642 0.75 Flow -X0, pH -XX 297.52 583.19 583.19 1407.6

MCPV8T010 159 001 643 1.00 Flow -X0, pH -XX 172.07 335.53 335.53 861.17

MCPV8T012 159 001 644 1.25 Flow -X0, pH -XX 91.54 178.79 178.79 464.91

MCPV8T015 159 001 645 1.50 Flow -X0, pH -XX 62.22 121.42 121.42 331.43

MCPV8TO20 159 001 646 2.00 Flow -X0, pH -XX 36.32 71.44 71.44 192.89

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

K-Factors for PVC Tees, SCH 80

PVC Tees, SCH 80 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

MPV8T005F 159 001 614 0.50 Flow -X0, pH -XX 520.12 1027.1 1027.1 2277.0

MPV8T007F 159 001 615 0.75 Flow -X0, pH -XX 297.52 583.19 583.19 1407.6

MPV8T010F 159 001 616 1.00 Flow -X0, pH -XX 172.07 335.53 335.53 861.17

MPV8T012F 159 001 617 1.25 Flow -X0, pH -XX 91.54 178.79 178.79 464.91

MPV8T015F 159 001 618 1.50 Flow -X0, pH -XX 62.22 121.42 121.42 331.43

MPV8T020F 159 001 619 2.00 Flow -X0, pH -XX 36.32 71.44 71.44 192.89

K-Factors for CPVC Tees, SCH 80

CPVC Tees, SCH 80 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

MCPV8T005F 159 001 632 0.50 Flow -X0, pH -XX 520.12 1027.1 1027.1 2277.0

MCPV8T007F 159 001 633 0.75 Flow -X0, pH -XX 297.52 583.19 583.19 1407.6

MCPV8T010F 159 001 634 1.00 Flow -X0, pH -XX 172.07 335.53 335.53 861.17

MCPV8T012F 159 001 635 1.25 Flow -X0, pH -XX 91.54 178.79 178.79 464.91

MCPV8T015F 159 001 636 1.50 Flow -X0, pH -XX 62.22 121.42 121.42 331.43

MCPV8T020F 159 001 637 2.00 Flow -X0, pH -XX 36.32 71.44 71.44 192.89

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-X0-XX, 3-272X-XX

Page 129: GF Piping Systems worldwide at home

129

K-Fa

ctor

s

K-Factors for PVC Clamp-on Saddle

PVC Clamp-on Saddle, SCH 80 SCH 80 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

PV8S020 159 000 637 2.00 Flow -X0, pH -XX 32.4800 66.7390 66.7390 193.8300

PV8S025 159 000 638 2.50 Flow -X0, pH -XX 21.8330 42.9940 42.9940 138.0100

PV8S030 198 150 577 3.00 Flow -X0, pH -XX 13.5410 26.6520 26.6520 83.8900

PV8S040 198 150 578 4.00 Flow -X1 7.6258 15.0060 15.0060 40.8800

PV8S060 198 150 579 6.00 Flow -X1 4.1623 8.3246 8.3246 22.5300

PV8S080 159 000 639 8.00 Flow -X1 2.3705 5.0164 5.0164 12.5200

PVC Clamp-on Saddle, SCH 40 SCH 40 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

PV8S020 159 000 637 2.00 Flow -X0, pH -XX 27.3500 54.7000 54.7000 180.0100

PV8S025 159 000 638 2.50 Flow -X0, pH -XX 18.8740 37.1590 37.1590 123.7200

PV8S030 198 150 577 3.00 Flow -X0, pH -XX 12.6380 23.6970 23.6970 75.8100

PV8S040 198 150 578 4.00 Flow -X1 6.7282 13.4560 13.4560 41.8700

PV8S060 198 150 579 6.00 Flow -X1 3.7297 7.4594 7.4594 19.7100

PV8S080 159 000 639 8.00 Flow -X1 2.1527 4.5292 4.5292 11.7300

• For use with P51530-X0/-X1, 3-2536-X0/-X1, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX, 3-272X-XX

K-Factors for PVC Glue-on Saddle

PVC Glue-on Saddle, SCH 80 SCH 80 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2551

[inch] Type gpm gpm gpm

PV8S100 159 000 695 10.00 Flow -X2 1.5300 3.0600 7.9400

PV8S120 159 000 696 12.00 Flow -X2 1.0600 2.1600 5.7100

PVC Glue-on Saddle, SCH 40 SCH 40 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2551

[inch] Type gpm gpm gpm

PV8S100 159 000 695 10.00 Flow -X2 1.3500 2.8000 7.4300

PV8S120 159 000 696 12.00 Flow -X2 0.9600 1.9800 5.2300

• For use with P51530-X2, 3-2536-X2, 3-2551-X2-XX

Page 130: GF Piping Systems worldwide at home

130

K-Factors for Carbon Steel Threaded Tees with NPT Threads, SCH 40

Carbon Steel Threaded Tees K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

CS4T005 198 801 459 0.50 Flow -X0, pH -XX 370.2000 756.0000 756.0000 1572.6600

CS4T007 198 801 460 0.75 Flow -X0, pH -XX 212.0600 438.6900 438.6900 1086.7300

CS4T010 198 801 461 1.00 Flow -X0, pH -XX 141.1400 286.7800 286.7800 582.3400

CS4T012 198 801 462 1.25 Flow -X0, pH -XX 60.6550 121.2200 121.2200 377.4800

CS4T015 198 801 419 1.50 Flow -X0, pH -XX 45.3500 91.1390 91.1390 267.7900

CS4T020 198 801 463 2.00 Flow -X0, pH -XX 26.7670 54.4680 54.4680 167.8500

K-Factors for 316 SS (1.4401) Threaded Tee with NPT Threads and PVDF Insert, SCH 40

316 SS Threaded Tees K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

CR4T005 198 801 554 0.50 Flow -X0, pH -XX 358.9600 734.2000 734.2000 1601.2600

CR4T007 198 801 555 0.75 Flow -X0, pH -XX 202.6100 412.1000 412.1000 937.7800

CR4T010 198 801 556 1.00 Flow -X0, pH -XX 127.1400 252.7000 252.7000 606.1800

CR4T012 198 801 783 1.25 Flow -X0, pH -XX 61.9100 128.1200 128.1200 279.6800

CR4T015 198 801 784 1.50 Flow -X0, pH -XX 40.4100 77.3200 77.3200 147.6500

CR4T020 198 801 785 2.00 Flow -X0, pH -XX 22.3000 45.7800 45.7800 111.9000

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Page 131: GF Piping Systems worldwide at home

131

K-Fa

ctor

s

K-Factors for Galvanized Iron Threaded Tee with NPT Threads and PVDF Insert, SCH 40

Galvanized Iron Threaded Tee K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

IR4T010 198 801 421 1.00 Flow -X0, pH -XX 104.5400 213.0100 213.0100 558.5000

IR4T012 198 801 422 1.25 Flow -X0, pH -XX 62.9790 127.7500 127.7500 334.4500

IR4T015 198 801 423 1.50 Flow -X0, pH -XX 46.6880 94.4010 94.4010 248.9700

IR4T020 198 801 424 2.00 Flow -X0, pH -XX 29.4590 59.4200 59.4200 146.000

K-Factors for Brass Threaded Tee with NPT Threads and PVDF Insert, SCH 40

Brass Threaded Tee K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

BR4T010 198 801 770 1.00 Flow -X0, pH -XX 104.5400 213.0100 213.0100 582.3400

BR4T012 198 801 771 1.25 Flow -X0, pH -XX 62.9790 127.7500 127.7500 330.5400

BR4T015 198 801 772 1.50 Flow -X0, pH -XX 46.6880 94.4010 94.4010 254.7600

BR4T020 198 801 773 2.00 Flow -X0, pH -XX 29.4590 59.4200 59.4200 157.3600

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

Page 132: GF Piping Systems worldwide at home

132

K-Factors for Copper Sweat-on Tee with PVDF Insert

Copper Sweat-on Tee, SCH K SCH K K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

CUKT005 198 801 687 0.50 Flow -X0, pH -XX 443.2100 917.8400 917.8400 2459.1900

CUKT007 198 801 688 0.75 Flow -X0, pH -XX 212.1600 428.2700 428.2700 1108.0200

CUKT010 198 801 689 1.00 Flow -X0, pH -XX 127.1800 256.4300 256.4300 649.8700

CUKT012 198 801 690 1.25 Flow -X0, pH -XX 88.2180 176.4400 176.4400 422.0300

CUKT015 198 801 691 1.50 Flow -X0, pH -XX 56.9620 115.6900 115.6900 281.4300

CUKT020 198 801 418 2.00 Flow -X0, pH -XX 29.3700 63.3850 63.3850 136.0200

Copper Sweat-on Tee, SCH L SCH L K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

CUKT005 198 801 687 0.50 Flow -X0, pH -XX 414.4100 858.2200 858.2200 2406.3000

CUKT007 198 801 688 0.75 Flow -X0, pH -XX 191.0900 385.7400 385.7400 1174.7700

CUKT010 198 801 689 1.00 Flow -X0, pH -XX 119.8400 241.6400 241.6400 672.2800

CUKT012 198 801 690 1.25 Flow -X0, pH -XX 85.4510 170.9000 170.9000 402.8400

CUKT015 198 801 691 1.50 Flow -X0, pH -XX 55.1600 112.0300 112.0300 294.9900

CUKT020 198 801 418 2.00 Flow -X0, pH -XX 28.6050 61.7400 61.7400 149.6300

K-Factors for 316 SS Weldolets with PVDF Insert, SCH 40

316 SS Weldolets K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

CR4W025 198 801 786 2.50 Flow -X0, pH -XX 18.8000 37.6000 37.6000 106.3100

CR4W030 198 801 787 3.00 Flow -X0, pH -XX 12.1700 24.3400 24.3400 72.2700

CR4W040 198 801 788 4.00 Flow -X0, pH -XX 6.9600 13.9200 13.9200 36.8400

CR4W050 198 801 789 5.00 Flow -X1 5.2600 10.8600 10.8600 29.2800

CR4W060 198 801 790 6.00 Flow -X1 3.6900 7.5200 7.5200 20.2900

CR4W080 198 801 791 8.00 Flow -X1 2.1300 4.3400 4.3400 11.7300

CR4W100 198 801 792 10.00 Flow -X2 1.3500 2.7600 - 7.4500

CR4W120 198 801 793 12.00 Flow -X2 0.9600 1.9400 - 5.2400

• For use with P51530-X0, 3-2536-X0, 3-8510-X0, 3-8512-X0, 3-2537-XC-X0, 3-2551-X0-XX, 3-272X-XX

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Page 133: GF Piping Systems worldwide at home

133

K-Fa

ctor

s

K-Factors for Carbon Steel Weld-on Weldolets, SCH 40

Carbon Steel Weldolets K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

CS4W025 198 801 464 2.50 Flow -X0, pH -XX 18.8000 37.6000 37.6000 105.7000

CS4W030 198 801 557 3.00 Flow -X0, pH -XX 12.1700 24.3400 24.3400 70.6800

CS4W040 198 801 552 4.00 Flow -X0, pH -XX 6.9600 13.9200 13.9200 36.3800

CS4W050 198 801 465 5.00 Flow -X1 5.2600 10.8600 10.8600 29.2800

CS4W060 198 801 553 6.00 Flow -X1 3.6900 7.5200 7.5200 20.2900

CS4W080 198 801 574 8.00 Flow -X1 2.1300 4.3400 4.3400 11.7300

CS4W100 198 801 575 10.00 Flow -X2 1.3500 2.7600 - 7.4500

CS4W120 198 801 576 12.00 Flow -X2 0.9600 1.9400 - 5.2400

K-Factors for Brass Brazolet with PVDF Insert for Use with Copper Pipe, SCH 40

Brass Brazolet K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

BR4B025 198 801 794 2.50 Flow -X0, pH -XX 18.8000 37.6000 37.6000 117.3100

BR4B030 198 801 795 3.00 Flow -X0, pH -XX 12.1700 24.3400 24.3400 78.6200

BR4B030 198 801 796 4.00 Flow -X0, pH -XX 6.9600 13.9200 13.9200 45.1300

BR4B050 198 801 797 5.00 Flow -X1 5.2600 10.8600 10.8600 32.7900

BR4B060 198 801 798 6.00 Flow -X1 3.6900 7.5200 7.5200 22.7300

BR4B080 198 801 799 8.00 Flow -X1 2.1300 4.3400 4.3400 13.1400

BR4B100 198 801 800 10.00 Flow -X2 1.3500 2.7600 - 8.3400

BR4B120 198 801 801 12.00 Flow -X2 0.9600 1.9400 - 5.8700

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

Page 134: GF Piping Systems worldwide at home

134

K-Factors for Iron Strap-on Saddle

Iron Strap-on Saddle, SCH 80 SCH 80 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

IR8S020 198 801 425 2.00 Flow -X0, pH -XX 32.3600 64.7200 64.7200 194.8500

IR8S025 198 801 426 2.50 Flow -X0, pH -XX 22.2200 42.4800 42.4800 142.2800

IR8S030 198 801 427 3.00. Flow -X0, pH -XX 13.4200 26.4200 26.4200 87.5300

IR8S040 198 801 420 4.00 Flow -X0, pH -XX 7.6600 14.7000 14.7000 40.6200

IR8S050 198 801 429 5.00 Flow -X1 5.8600 12.1800 12.1800 29.2800

IR8S060 198 801 430 6.00 Flow -X1 4.0900 8.4400 8.4400 22.3000

IR8S080 198 801 431 8.00 Flow -X1 2.3300 4.9000 4.9000 12.5200

IR8S100 198 801 432 10.00 Flow -X2 1.5300 3.0600 - 7.9400

IR8S120 198 801 433 12.00 Flow -X2 1.0600 2.1600 - 5.6500

Iron Strap-on Saddle, SCH 40 SCH 40 K-Factors

Part No. Code No. Pipe Size Sensor 515/8510 2536/8512 2537 2551

[inch] Type gpm gpm gpm gpm

IR8S020 198 801 425 2.00 Flow -X0, pH -XX 26.8200 53.6400 53.6400 185.3500

IR8S025 198 801 426 2.50 Flow -X0, pH -XX 18.8000 37.6000 37.6000 127.4700

IR8S030 198 801 427 3.00 Flow -X0, pH -XX 11.9900 23.2200 23.2200 76.6200

IR8S040 198 801 420 4.00 Flow -X0, pH -XX 6.8500 13.2600 13.2600 40.2300

IR8S050 198 801 429 5.00 Flow -X1 5.3300 11.0400 11.0400 27.3200

IR8S060 198 801 430 6.00 Flow -X1 3.7600 7.2400 7.2400 19.7100

IR8S080 198 801 431 8.00 Flow -X1 2.1300 4.4000 4.4000 11.6100

IR8S100 198 801 432 10.00 Flow -X2 1.3500 2.8000 - 7.3600

IR8S120 198 801 433 12.00 Flow -X2 0.9600 1.9800 - 5.1800

K-Factors for Metalex Strap-on Saddle, SCH 40

Metalex Strap-on Saddle K-Factors

Part No. Code No. Pipe Size Sensor 525

[inch] Type gpm

P526-1020 159 000 484 2.00 P525-3, P525-3S 64.8080

P526-1025 159 000 485 2.50 P525-3, P525-3S 44.6850

P526-1030 159 000 486 3.00 P525-3, P525-3S 28.5790

P526-1040 159 000 487 4.00 P525-3, P525-3S 16.3020

P526-1050 159 000 488 5.00 P525-3, P525-3S 10.2370

P526-1060 159 000 489 6.00 P525-3, P525-3S 7.0057

P526-1080 159 000 490 8.00 P525-3, P525-3S 3.9641

P526-1100 159 000 491 10.00. P525-3, P525-3S 2.4960

P526-1120 159 000 492 12.00 P525-3, P525-3S 1.6894

• For use with P51530-X0/-X1/-X2, 3-2536-X0/-X1/-X2, 3-8510-X0/-X1, 3-8512-X0/-X1, 3-2537-XC-X0/-X1, 3-2551-X0-XX/-X1-XX/-X2-XX, 3-272X-XX

• For use with P525-3 and P525-3S only

Page 135: GF Piping Systems worldwide at home

135

K-Fa

ctor

s

K-Factors for Metalex Socket Weld Mini-Tap, SCH 40

Metalex Socket Weld Mini-Tap K-Factors

Part No. Code No. Pipe Size Sensor 525

[inch] Type gpm

P526-2005 198 840 501 0.50 P525-1, P525-1S 873.0300

P526-2007 198 840 502 0.75 P525-1, P525-1S 515.4100

P526-2010 198 840 503 1.00 P525-1, P525-1S 266.1700

K-Factors for Metalex Weld-on Mini-Tap, SCH 40

Metalex Weld-on Mini-Tap K-Factors

Part No. Code No. Pipe Size Sensor 525

[inch] Type gpm

P526-2012 159 000 494 1.25 P525-2, P525-2S 148.8400

P526-2015 159 000 506 1.50 P525-2, P525-2S 107.9800

P526-2020 159 000 495 2.00 P525-2, P525-2S 64.8080

P526-2025 159 000 496 2.50 P525-2, P525-2S 44.6850

P526-2030 159 000 497 3.00 P525-2, P525-2S 28.5790

P526-2040 159 000 498 4.00 P525-2, P525-2S 16.3020

P526-2050 159 000 499 5.00 P525-2, P525-2S 10.2370

P526-2060 159 000 500 6.00 P525-2, P525-2S 7.0057

P526-2080 159 000 501 8.00 P525-2, P525-2S 3.9641

P526-2100 159 000 502 10.00 P525-2, P525-2S 2.4690

P526-2120 159 000 503 12.00 P525-2, P525-2S 1.6894

d DN PVC-C Socket PE 80 Socket PE 100 Butt PP-R Butt

20 15 723600106 734600106 753608616 728608506

25 20 723600107 734600107 753608617 728608507

32 25 723600108 734600108 753608618 728608508

40 32 723600109 734600109 753608619 728608509

50 40 723600110 734600110 753608620 728608510

63 50 723600111 734600111 753608621 728608511

To install these union ends, please select an installation T-fitting in PVC-U, PP, PVDF and replace the original union end.

Union Ends

• For use with P525-1 and P525-1S only

• For use with P525-2 and P525-2S only

Page 136: GF Piping Systems worldwide at home

136

K-Factors for 3-2552-1X - X - XX and 3-2552-2X - X - XX Magmeters

Pipe Size (ANSI) Schedule OD

(Inches)WALL (Inches)

ID (Inches)

H Dim-1 Version

H Dim-2 Version

K-FactorPulse/Gal

Factory set 20 mA (GPM)

Inch Inch

2 40 2.375 0.15 2.07 8 16/32 10 16/32 174.83 171.6

80 2.375 0.22 1.94 8 15/32 10 15/32 198.68 151.0

2½ 40 2.875 0.20 2.47 8 14/32 10 14/32 122.54 244.8

80 2.875 0.28 2.32 8 12/32 10 12/32 138.42 216.7

3 40 3.500 0.22 3.07 8 12/32 10 12/32 79.36 378.0

80 3.500 0.30 2.90 8 10/32 10 9/32 88.82 337.8

3½ 40 4.000 0.23 3.55 8 10/32 10 10/32 59.34 505.6

80 4.000 0.32 3.36 8 8/32 10 8/32 66.01 454.5

4 40 4.500 0.24 4.03 8 8/32 10 8/32 46.09 651.0

80 4.500 0.34 3.83 8 6/32 10 5/32 51.03 587.9

5 40 5.563 0.26 5.05 8 4/32 10 4/32 29.33 1023

80 5.563 0.38 4.81 8 10 32.25 930.4

6 40 6.625 0.28 6.07 8 10 20.31 1477

80 6.625 0.43 5.76 7 28/32 9 28/32 22.51 1333

8 40 8.625 0.32 7.98 7 24/32 9 24/32 11.73 2558

80 8.625 0.50 7.63 7 20/32 9 20/32 12.85 2335

10 40 10.75 0.37 10.0 7 16/32 9 16/32 7.440 4032

80 10.75 0.59 9.56 7 11/32 9 11/32 8.170 3672

12 STD 12.75 0.38 12.0 7 10/32 9 10/32 5.187 5783

XHY 12.75 0.50 11.8 7 7/32 9 6/32 5.410 5545

14 30 14.00 0.38 13.3 7 6/32 9 6/32 4.255 7051

XHY 14.00 0.50 13.0 7 3/32 9 3/32 4.420 6787

16 30 16.00 0.38 15.3 7 9 3.212 9340

40/XHY 16.00 0.50 15.0 6 28/32 8 28/32 3.320 9036

18 STD 18.00 0.38 17.3 6 25/32 8 25/32 2.510 11950

XHY 18.00 0.50 17.0 6 22/32 8 22/32 2.585 11610

20 20/STD 20.00 0.38 19.3 6 18/32 8 19/32 2.016 14880

30/XHY 20.00 0.50 19.0 6 16/32 8 16/32 2.069 14500

22 20/STD 22.00 0.38 21.3 6 12/32 8 12/32 1.654 18136

30/XHY 22.00 0.50 21.0 6 9/32 8 9/32 1.694 17711

24 20/STD 24.00 0.38 23.3 6 6/32 8 6/32 1.382 21710

XHY 24.00 0.50 23.0 6 3/32 8 3/32 1.412 21246

Page 137: GF Piping Systems worldwide at home

137

K-Fa

ctor

s

K-Factors for 3-2552-1X - X - XX and 3-2552-2X - X - XX Magmeters

Pipe Size (ANSI) Schedule OD

(Inches)WALL

(Inches) ID (Inches) H Dim -1 Version

H Dim -2 Version

K-FactorPulse/Gal

Factory set 20 mA (GPM)

Inch Inch

26 STD 26 0.38 25.25 6 8 1.172 25606

20/XHY 26 0.50 25.00 5 28/32 7 28/32 1.195 25101

28 STD 28 0.38 27.25 5 25/32 7 25/32 1.006 29823

20/XHY 28 0.50 27.00 5 22/32 7 22/32 1.025 29278

30 STD 30 0.38 29.25 5 19/32 7 19/32 0.873 34361

20/XHY 30 0.50 29.00 5 16/32 7 16/32 0.888 33776

32 STD 32 0.38 31.25 5 12/32 7 12/32 0.765 39220

20/XHY 32 0.50 31.00 5 9/32 7 9/32 0.777 38595

34 STD 34 0.38 33.25 5 6/32 7 6/32 0.676 44401

20/XHY 34 0.50 33.00 5 3/32 7 3/32 0.686 43736

36 STD 36 0.38 35.25 5 7 0.601 49903

20/XHY 36 0.50 35.00 4 28/32 6 28/32 0.610 49198

38 STD 38 0.38 37.25 4 25/32 6 25/32 0.538 55727

XHY 38 0.50 37.00 4 22/32 6 22/32 0.546 54981

40 STD 40 0.38 39.25 4 19/32 6 19/32 0.485 61872

XHY 40 0.50 39.00 4 16/32 6 16/32 0.491 61086

42 STD 42 0.38 41.25 4 12/32 6 12/32 0.439 68338

XHY 42 0.50 41.00 4 9/32 6 9/32 0.444 67512

48 STD 48 0.38 47.25 3 25/32 5 25/32 0.335 89664

XHY 48 0.50 47.00 3 22/32 5 22/32 0.338 88717

54 STD 54.00 0.38 53.25 3 6/32 5 6/32 0.2634 113881

XHY 54.00 0.50 53.00 3 3/32 5 3/32 0.2659 112814

60 STD 60.00 0.38 59.25 2 19/32 4 19/32 0.2128 140990

XHY 60.00 0.50 59.00 2 15/32 4 16/32 0.2146 139802

66 STD 66.00 0.38 65.25 1 31/32 4 0.1754 170991

XHY 66.00 0.50 65.00 1 28/32 3 29/32 0.1768 169683

72 STD 72.00 0.38 71.25 1 12/32 3 13/32 0.1471 203883

XHY 72.00 0.50 71.00 1 9/32 3 10/32 0.1482 202455

78 STD 78.00 0.38 77.25 25/32 2 26/32 0.1252 239667

XHY 78.00 0.50 77.00 22/32 2 22/32 0.1260 238119

84 STD 84.00 0.38 83.25 6/32 2 6/32 0.1078 278343

XHY 84.00 0.50 83.00 3/32 2 3/32 0.1084 276674

90 STD 90.00 0.375 89.25 1 19/32 0.0938 319910

XHY 90.00 0.500 89.00 1 16/32 0.0943 318120

96 STD 96.00 0.375 95.25 1 0.0823 364369

XHY 96.00 0.500 95.00 29/32 0.0828 362459

102 STD 102.00 0.38 101.25 13/32 0.0729 411720

XHY 102.00 0.50 101.00 10/32 0.0732 409690

108 STD 108.00 0.38

XHY 108.00 0.50

120 STD 120.00 0.38

XHY 120.00 0.50

144 STD 144.00 0.38

XHY 144.00 0.50

Page 138: GF Piping Systems worldwide at home

138

K-Factors for 3-2552-3X - X - XX Magmeters

Pipe Size (ANSI) Schedule OD (Inches) WALL

(Inches) ID (Inches) H Dim mm-3X Version

K-FactorPulse/Gal

Factory set 20 mA (GPM)

Inch

2 40 2.375 0.15 2.07 16 5/32 174.83 171.6

80 2.375 0.22 1.94 16 3/32 198.68 151.0

2½ 40 2.875 0.20 2.47 16 122.54 244.8

80 2.875 0.28 2.32 16 138.42 216.7

3 40 3.500 0.22 3.07 15 31/32 79.36 378.0

80 3.500 0.30 2.90 15 29/32 88.82 337.8

3½ 40 4.000 0.23 3.55 15 29/32 59.34 505.6

80 4.000 0.32 3.36 15 27/32 66.01 454.5

4 40 4.500 0.24 4.03 15 28/32 46.09 651.0

80 4.500 0.34 3.83 15 25/32 51.03 587.9

5 40 5.563 0.26 5.05 15 24/32 29.33 1023

80 5.563 0.38 4.81 15 21/32 32.25 930.4

6 40 6.625 0.28 6.07 15 20/32 20.31 1477

80 6.625 0.43 5.76 15 16/32 22.51 1333

8 40 8.625 0.32 7.98 15 12/32 11.73 2558

80 8.625 0.50 7.63 15 8/32 12.85 2335

10 40 10.75 0.37 10.0 15 4/32 7.440 4032

80 10.75 0.59 9.56 14 30/32 8.170 3672

12 STD 12.75 0.38 12.0 14 30/32 5.187 5783

XHY 12.75 0.50 11.8 14 26/32 5.410 5545

14 30 14.00 0.38 13.3 14 26/32 4.255 7051

XHY 14.00 0.50 13.0 14 22/32 4.420 6787

16 30 16.00 0.38 15.3 14 19/32 3.212 9340

40/XHY 16.00 0.50 15.0 14 16/32 3.320 9036

18 STD 18.00 0.38 17.3 14 13/32 2.510 11950

XHY 18.00 0.50 17.0 14 10/32 2.585 11610

20 20/STD 20.00 0.38 19.3 14 6/32 2.016 14880

30/XHY 20.00 0.50 19.0 14 3/32 2.069 14500

22 20/STD 22.00 0.38 21.3 14 1.654 18136

30/XHY 22.00 0.50 21.0 13 29/32 1.694 17711

24 20/STD 24.00 0.38 23.3 13 26/32 1.382 21710

XHY 24.00 0.50 23.0 13 22/32 1.412 21246

Page 139: GF Piping Systems worldwide at home

139

K-Fa

ctor

s

K-Factors for 3-2552-3X - X - XX Magmeters

Pipe Size (Inch) Schedule OD (Inches) WALL

(Inches) ID (Inches) H Dim mm-3X Version

K-FactorPulse/Gal

Factory set 20 mA (GPM)

Inch

26 STD 26 0.38 25.25 13 19/32 1.172 25606

20/XHY 26 0.50 25.00 13 16/32 1.195 25101

28 STD 28 0.38 27.25 13 13/32 1.006 29823

20/XHY 28 0.50 27.00 13 10/32 1.025 29278

30 STD 30 0.38 29.25 13 6/32 0.873 34361

20/XHY 30 0.50 29.00 13 3/32 0.888 33776

32 STD 32 0.38 31.25 13 0.765 39220

20/XHY 32 0.50 31.00 12 29/32 0.777 38595

34 STD 34 0.38 33.25 12 26/32 0.676 44401

20/XHY 34 0.50 33.00 12 22/32 0.686 43736

36 STD 36 0.38 35.25 12 19/32 0.601 49903

20/XHY 36 0.50 35.00 12 16/32 0.610 49198

38 STD 38 0.38 37.25 12 13/32 0.538 55727

XHY 38 0.50 37.00 12 10/32 0.546 54981

40 STD 40 0.38 39.25 12 6/32 0.485 61872

XHY 40 0.50 39.00 12 3/32 0.491 61086

42 STD 42 0.38 41.25 12 0.439 68338

XHY 42 0.50 41.00 11 29/32 0.444 67512

48 STD 48 0.38 47.25 11 13/32 0.335 89664

54 STD 54.00 0.38 53.25 10 26/32 0.2634 113881

XHY 54.00 0.50 53.00 10 22/32 0.2659 112814

60 STD 60.00 0.38 59.25 10 6/32 0.2128 140990

XHY 60.00 0.50 59.00 10 3/32 0.2146 139802

66 STD 66.00 0.38 65.25 9 19/32 0.1754 170991

XHY 66.00 0.50 65.00 9 16/32 0.1768 169683

72 STD 72.00 0.38 71.25 9 0.1471 203883

XHY 72.00 0.50 71.00 8 29/32 0.1482 202455

78 STD 78.00 0.38 77.25 8 13/32 0.1252 239667

XHY 78.00 0.50 77.00 8 10/32 0.1260 238119

84 STD 84.00 0.38 83.25 7 26/32 0.1078 278343

XHY 84.00 0.50 83.00 7 22/32 0.1084 276674

90 STD 90.00 0.375 89.25 7 6/32 0.0938 319910

XHY 90.00 0.500 89.00 7 3/32 0.0943 318120

96 STD 96.00 0.375 95.25 6 19/32 0.0823 364369

XHY 96.00 0.500 95.00 6 16/32 0.0828 362459

102 STD 102.00 0.38 101.25 6 0.0729 411720

XHY 102.00 0.50 101.00 5 29/32 0.0732 409690

Page 140: GF Piping Systems worldwide at home

140

Service & Support

Quality & Environment SystemsWe are fully registered to ISO 9001 and ISO 14001 through Underwriters Laboratories Inc. under the scope of industrial instruments for measurement, display, and control of process variables, and related products. All assembly processes, calibration and test procedures are controlled through our Quality and Environmental Management System modelled to comply with ISO 9001 and ISO 14001. Our very culture is one of developing safe processes and procedures which continues to improve our systems, products, and environments.

Data Sheets/CatalogueFull product and application information is found in our published literature, now available in French and German languages as well as English. Full specifications for every product are provided with temperature/pressure graphs, a system overview to outline how parts fit together, an ordering matrix, and even application tips and dimensions are included. Additionally, the catalogue includes a system compatibility, a side-by-side product specification matrix, and a comprehensive technical reference section.

Technical SupportQualified technical support representatives are available at each of our sales companies to assist you with your product and application questions. Just contact our specialists on the telephone numbers or email address shown on the last page of this catalogue, or visit our website for supporting documentation. Visit www.gfsignet.com

Regulations, Approvals and CertificationElectronic products meet the requirements of European Directives where applicable: Electromagnetic Compatibility (EMC), Low Voltage (LV), Conformité Européenne (CE), Waste of Electrical and Electronic Equipment (WEEE), and Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS). Relevant products are also approved/listed by the Nationally Recognized Testing Laboratories (NRTLs) such as Underwriters Laboratories (UL), Factory Mutual (FM), and/or Intertek (ETL). Certificates areavailable upon request.

Page 141: GF Piping Systems worldwide at home

141

Info

rmat

ion

Info

rmat

ion

SpecialsAny non-catalogue product is classified as a “special request”. Should you require a sensor with an alternative material that is a non-molded item to suit your specific application requirement, or an additional cable length than provided with your product

of choice, we remain flexible to accommodate your needs. Contact your local sales company for further information.

TrainingGF Piping Systems offers comprehensive product and application training in numerous countries around the world. The Measurement & Control program covers detailed application examples for all products including Flow, pH/ORP, Turbidity, Chlorine, Conductivity/Resistivity, Pressure, Level

and Temperature measurement systems. Good practices are taught for installation and calibration of all products so users may obtain the most optimum performance from their measurement package. Contact your local sales company for further information.

WebsiteQuickly access a world of information easily by going to www.gfsignet.com. Whether you wish to print operation manuals (available in six languages) for installation and calibration, or a data sheet for specifications, or even an FAQ to answer that question you have been meaning to get answered, you will find it all here. Additionally, we list sales company

contact information, warranty statement, CAD drawings, Tech-Tips, copies of certificates, an Applications Library, Articles, and an easy-to-use K-Factor Calculator.

The Difference with GF Piping Systems:

Simplicity •

Reliability •

Economy •

Global Availability & Support •

Packaged Piping Systems Solutions •

Page 142: GF Piping Systems worldwide at home

Global Installation F

ittings and K-Factors

3-0000.706 (C-10/10) #1285 (10/10)©Copyright Georg Fischer Signet LLC.3401 Aerojet Avenue, El Monte, CA 91731-2882Tel (626) 571-2770, Fax (626) 573-2057Printed in U.S.A.

GF Piping Systems worldwide at homewww.gfsignet.com

Global Installation Fittingsand K-Factors

The technical data is not binding. They neither constitute expressly warranted characteristics nor guaranteed properties nor a guaranteed durability. They are subject to modification. Our General Terms of Sale apply. Adding Quality to People’s Lives

Our sales companies and representatives ensure local customer

support in over 100 countries.

K-Factor

GlobalArgentina / Southern South AmericaGeorg Fischer Central Plastics Sudamérica S.R.L.Buenos Aires, ArgentinaPhone +5411 4512 02 [email protected]

AustraliaGeorge Fischer Pty LtdRiverwood NSW 2210 AustraliaPhone +61(0)2 9502 8000 [email protected]

Austria Georg Fischer Rohrleitungssysteme GmbH3130 HerzogenburgPhone +43(0)2782 856 [email protected]

Belgium / LuxembourgGeorg Fischer NV/SA1070 Bruxelles/BrüsselPhone +32(0)2 556 40 [email protected]

BrazilGeorge Fischer Ltda04795-100 São PauloPhone +55(0)11 5525 [email protected]

CanadaGeorg Fischer Piping Systems LtdBrampton, ON L6T 4E3Phone +1(905)792 8005Fax +1(905)792 [email protected]

ChinaGeorg Fischer Piping Systems Ltd Shanghai Pudong, Shanghai 201319Phone +86(0)21 58 13 33 33 [email protected]

Denmark / IcelandGeorg Fischer A/S2630 TaastrupPhone +45 (0)70 22 19 [email protected]

FranceGeorg Fischer SAS95932 Roissy Charles de Gaulle CedexPhone +33(0)1 41 84 68 [email protected]

GermanyGeorg Fischer GmbH73095 Albershausen Phone +49(0)7161 [email protected]

IndiaGeorg Fischer Piping Systems Ltd400 076 MumbaiPhone +91 224007 [email protected]

ItalyGeorg Fischer S.p.A.20063 Cernusco S/N (MI)Phone +3902 921 [email protected]

NorwayGeorg Fischer AS1351 Rud Phone +47(0)67 18 29 [email protected]

PolandGeorg Fischer Sp. z o.o.05-090 Sekocin Nowy Phone +48(0)22 31 31 0 50 [email protected]

RomaniaGeorg Fischer Piping Systems Ltd020257 Bucharest - Sector 2Phone +40(0)21 230 53 [email protected]

RussiaGeorg Fischer Piping SystemsMoscow 125047Tel. +7 495 258 60 [email protected]

SingaporeGeorge Fischer Pte Ltd528 872 SingaporePhone +65(0)67 47 06 [email protected]

Spain / PortugalGeorg Fischer S.A.28046 MadridPhone +34(0)91 781 98 [email protected]

Sweden / FinlandGeorg Fischer AB117 43 StockholmPhone +46(0)8 506 775 00info.se.ps@georgfischer.comwww.georgfischer.sewww.georgfischer.fi

SwitzerlandGeorg Fischer Rohrleitungssysteme (Schweiz) AG8201 SchaffhausenPhone +41(0)52 631 30 [email protected]

TaiwanGeorg Fischer Piping SystemsSan Chung City, Taipei HsienPhone +886 2 8512 2822Fax +886 2 8512 2823www.georgfischer.tw

United Kingdom / IrelandGeorge Fischer Sales LimitedCoventry, CV2 2STPhone +44(0)2476 535 [email protected]

USA / CaribbeanGeorg Fischer LLCTustin, CA 92780-7258Phone +1(714) 731 88 00 Toll Free 800 854 40 [email protected]

International Georg Fischer Piping Systems (Switzerland) Ltd.8201 Schaffhausen/SwitzerlandPhone +41(0)52 631 30 03Fax +41(0)52 631 28 [email protected]

JapanGeorg Fischer Ltd556-0011 Osaka, Phone +81(0)6 6635 [email protected]

Korea Georg Fischer Piping Systems463824, South Korea Phone +82 (0)31 8017 1450~3Fax +82 (0)31 8017 1454 [email protected]

MalaysiaGeorge Fischer (M) Sdn. Bhd.40460 Shah Alam, Selangor Darul EhsanPhone +60 (0)3 5122 [email protected]

Mexico / Northern Latin AmericaGeorg Fischer S.A. de C.V.Apodaca, Nuevo LeonCP66636 MexicoPhone +52 (81)1340 8586Fax +52 (81)1522 [email protected]

Middle EastGeorge Fischer Piping Systems Dubai, United Arab Emirates Phone +971 4 289 49 60 [email protected]

NetherlandsGeorg Fischer N.V.8161 PA EpePhone +31(0)578 678 222 [email protected]