german smart metering and european privacy...
TRANSCRIPT
10 – 25 Years
Smart Grid (and Metering)
Cus
tom
er
Sat
isfa
ctio
n
Web-
Services
In-Home
Display
Dynamic
Billing
Smart
HomeHAN
Energy
Pattern
Smart
Appliances
Privacy
Automated
Read-out
Prosumer
Role
3 Years 3 – 10 Years
AccessCyber
Real Time
Simulation
Phase
Balancing
Decentralized Energy
and Intelligence
Microgrid
100% Electrified
Transportation
Fault
Anticipation
Distribution Energy
Management System
1/16/2013 1© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
Energy Security Climate Protection
Energy
Storage
V2G
BEV
Bidirectional
Power Flow
Distributed
Energy Supply
WAN
Access
Management
Cyber
Security
Smart
Meters
Smart Meter
Infrastructure
Vault
Monitoring
Self Healing
GridSmart
Sensors
Station
Automation
Network
Automation
Feeder
Automation
Asset
Management
Identity
Management
Theft of Power
Detection
Outage
Management
Communication
Fault Indicators
Simulation
Real Time Condition
based Maintenance
Power Quality
Management
Balancing
Network
OptimizationLine Loss
Minimization
Management System
More
Renewables
ProblemsPrivacy
1/16/2013 2© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
http://www.daprim.dehttp://turn.org/http://www.smartmeterfilm.com/http://www.smartmeterlock.com/http://stopsmartmeters.orghttp://michiganstopsmartmeters.com/http://www.citizensforsafetechnology.com/http://www.stopsmartmetersbc.ca/html/http://stopsmartmeters.com.au
Current Activities in the Energy Sector IT Security for Smart Meter
IT Security Functionalities have been specified for Smart Meter Systems by TÜViT
and the Federal Office for Information Security (BSI)
together with
� Ministry of Economics
� BNetzA (Federal Network Agency)
� PTB (Physical Technical Authority)
� BfDI (Federal Commissioner for Data Protection and Freedom of Information)
Protection Profiles acc. to the international
3© TÜV Informationstechnik GmbH – Member of TÜV NORD Group1/16/2013
https://www.bsi.bund.de/DE/Themen/SmartMeter/smartmeter_node.html
The System Approach
Gateway
• Central component of the smart metering system
• Rich in functionality
• Evaluated in depth
Security Module
1/16/2013 5© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
Security Module
• Implementation of cryptographic primitives
• Secure Handling of key material
• Facilitate a fast rollout by re-use of existing technologies
Smart Metering System
• Comprising a Gateway and multiple meters
The main Functionality of the Gateway
Firewalling
• The Gateway has control over all information flows
• Connections may only have their origin locally
• The Gateway is not directly contactable
Metering Policies
• The Gateway receives data from meters
• The Gateway processes the data according to installed profiles
1/16/2013 6© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
• The Gateway processes the data according to installed profiles
• The Gateway submits the processed data to external parties in the WAN
Privacy Protection
• All information flows are transparent for the user
• The Gateway only allows encrypted and authenticated information flows
• The Gateway is able to conceal information flows if necessary
Communication for CLS
• The Gateway allow Controllable Local Systems to contact parties in the WAN
• The CLS have to follow the policies for information flow of the Gateway
The Functionality of the Security Module
Cryptography
• Key Negotiation for TLS
• Key Transport for content data
• Signature Generation and Verification
Storage of Key Material
1/16/2013 8© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
Storage of Key Material
• Asymmetric key material as the identity of the Gateway
• Symmetric keys to be used by the Gateway
Random Number Generation
• For internal use
• For various purposes to be used by the Gateway
„Privacy by Design” -PbD
Respecting the user
• In the area of new technologies for the smart grid consumers do often not have a choice to
participate or not
• Respecting the privacy of the consumers and prosumers is therefore a key aspect for the
success of all large rollouts of smart grid technologies
Respecting the user
• In the area of new technologies for the smart grid consumers do often not have a choice to
participate or not
• Respecting the privacy of the consumers and prosumers is therefore a key aspect for the
success of all large rollouts of smart grid technologies
PbD - Key AspectsPbD - Key Aspects
1/16/2013 9© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
• Privacy has got highest priority - The personal data of the consumers shall not be seen as part
of a business case
• Design Feature: Central functionalities of smart meter systems support privacy
• Privacy „by default“ - PbDef: Standard configuration is in “privacy-friendly mode”
• Transparency: Privacy is comprehensible for the consumer
• Privacy shall be considered during the whole life cycle (specification - roll-out - operation)
• Privacy has got highest priority - The personal data of the consumers shall not be seen as part
of a business case
• Design Feature: Central functionalities of smart meter systems support privacy
• Privacy „by default“ - PbDef: Standard configuration is in “privacy-friendly mode”
• Transparency: Privacy is comprehensible for the consumer
• Privacy shall be considered during the whole life cycle (specification - roll-out - operation)
PbD - Verification
Common Criteria: IT Security Functionalities
ISO 27001: Secure rollout and operation
PIA (Privacy Impact Assessments): Privacy of the life-cycle
PbD - Verification
Common Criteria: IT Security Functionalities
ISO 27001: Secure rollout and operation
PIA (Privacy Impact Assessments): Privacy of the life-cycle
� EU Directive
� Article 8 of the Charter of Fundamental Rights of the EU
� Implementation of Privacy and IT Security features
� Cooperation with national data protection authorities
� No traceability of personal data
Commission Recommendation (9.3.2012)on preparations for the roll-out of smart metering systems
Motivation
� No traceability of personal data
� Processing of personal data is minimised
� PIA (Privacy Impact Assessment) –Template for “data protection impact assessment”
� � appropriate Protective Measures
� Comment of EDPS (08.06.2012)
1/16/2013 10© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
Commission Recommendation (9.3.2012)on preparations for the roll-out of smart metering systems
Recommendations
� PIA
� Privacy by Design / Privacy by Default� Systematic Approach / Methodical Process ����
� 3 Levels: legislative, technical, organisational ����
� Privacy friendly option � Standard configuration ����
1/16/2013 11© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
� Privacy friendly option � Standard configuration ����
� Preference to PbD /PbDef Reference architecture ����
� Privacy Principles� Data Minimisation ����
� Transparency ����
� Empowerment of the Individual ����
� Security � cryptographic channel ����
� …
� Consumer‘s view
� Direct Readings ����
� Frequent Update ����
� Metering Operator’s view
� Remote Reading (with respect to privacy) ����
� Two-way communication (maintenance/control) ����
Commission Recommendation (9.3.2012)on preparations for the roll-out of smart metering systems
Minimal Functional Requirements
� Frequent Reading � for network planning (����)
� Commercial aspects
� Advanced tariff systems ����
� Remote on/off (����)
� Security / Privacy
� Secure data communication ����
� Fraud prevention and detection ����
� Distributed Generation
� Reactive Metering (����)
1/16/2013 12© TÜV Informationstechnik GmbH – Member of TÜV NORD Group
TÜV Informationstechnik GmbHMember of TÜV NORD Group
Markus BartschIT Security
Thank you very much for your attention!
Langemarckstr. 2045141 EssenGermany
Phone: +49 201 8999 – 616Fax: +49 201 8999 – 666E-Mail: [email protected]: www.tuvit.de
13© TÜV Informationstechnik GmbH – Member of TÜV NORD Group1/16/2013