31
General Specifications <<Contents>> <<Index>> ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1800 mm (20 to 72 in.)] Integral Type Flowmeter / Remote Flowtube Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180 Japan Tel.: +81-422-52-4443 Fax.: +81-422-52-2018 GS 01E25D11-01EN GS 01E25D11-01EN © Copyright Feb. 2012 (KP) 4th Edition Apr. 2017 (KP) n GENERAL DESCRIPTION The ADMAG TI Series AXW magnetic flowmeter has been developed based on Yokogawa’ s decades long experience in Magnetic Flowmeters. The AXW mag- netic flowmeter continues the tradition of high quality and reliability that has become synonymous with the Yokogawa name. The AXW series is ideal for general industrial pro- cess lines and water supply / sewage applications. With outstanding reliability and ease of operation and maintenance, developed on decades of field-proven experience, the AXW will increase user benefits while reducing total cost of ownership. The sizes are available from 25 mm to 1800 mm (1 to 72 in.). Besides fluorocarbon PTFE, lining can be se- lected from various rubber linings. Process connection also supports various specifications such as ASME EN, AS, and JIS. Note1: The terms “transmitter” and “sensor” in this document are used in the same manner as “converter” and “flowtube” respectively which have been used for our magnetic flowmeter models. Note2: This document covers the integral type flowmeters and remote flowtube (sensor) of the AXW magnetic flow- meter for sizes 500 to 1800 mm (20 to 72 in.). See the documents listed below regarding the sizes 25 to 400 mm and remote converters (transmitters) to be combined with. Especially when using remote converter AXFA11G, please note that the functional specifications are different from descriptions in this document. Product Document Number AXW Magnetic Flowmeter [Size: 500 to 1800 mm (20 to 72 in.)] Integral Type Flowmeter / Remote Flowtube GS 01E25D11-01EN (this doucment) AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Integral Type Flowmeter / Remote Sensor GS 01E24A01-01EN AXW4A Remote Transmitter AX01C Signal Cable AXFA11G Remote Converter AXFC Signal Cable GS 01E20C01-01E CONTENTS GENERAL DESCRIPTION P.1 FEATURES P.2 GENERAL P.2 CONSTRUCTION P.2 - Use, Construction P.2 - Process Connection P.3 - Lining Material, Electrode Material P.3 - Electrode Construction P.3 - Grounding Ring Material P.3 - Grounding Ring Construction P.3 - Gasket Material P.3 - Non-wetted Part Material, Coating P.3 - Electrical Connection, Wiring Terminal P.3 - Installation Work P.3 - Limitations on Specification Selection P.3 FUNCTIONS (Integral Type) P.4 CONFORMITY STANDARDS P.6 PERFORMANCE P.7 NORMAL OPERATING CONDITIONS P.8 CAUTIONS ON SELECTION AND INSTALLATION P.8 MODEL AND SUFFIX CODE P.11 OPTIONAL SPECIFICATION CODE P.13 TERMINAL CONFIGURATION AND WIRING P.16 DIMENSIONAL DRAWINGS P.17 SIZING DATA P.28 ORDERING INFORMATION P.29 RELATED INSTRUMENTS P.31 REFERENCE STANDARD P.31 TRADEMARKS P.31

Upload: others

Post on 06-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

GeneralSpecifications

<<Contents>> <<Index>>

ADMAG TI SeriesAXW Magnetic Flowmeter[Size: 500 to 1800 mm (20 to 72 in.)]Integral Type Flowmeter / Remote Flowtube

Yokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180 JapanTel.: +81-422-52-4443 Fax.: +81-422-52-2018

GS01E25D11-01EN

GS 01E25D11-01EN© Copyright Feb. 2012 (KP)

4th Edition Apr. 2017 (KP)

nGENERALDESCRIPTIONThe ADMAG TI Series AXW magnetic fl owmeter has been developed based on Yokogawa’ s decades long experience in Magnetic Flowmeters. The AXW mag-netic fl owmeter continues the tradition of high quality and reliability that has become synonymous with the Yokogawa name.The AXW series is ideal for general industrial pro-cess lines and water supply / sewage applications. With outstanding reliability and ease of operation and maintenance, developed on decades of fi eld-proven experience, the AXW will increase user benefi ts while reducing total cost of ownership.The sizes are available from 25 mm to 1800 mm (1 to 72 in.). Besides fl uorocarbon PTFE, lining can be se-lected from various rubber linings. Process connection also supports various specifi cations such as ASME EN, AS, and JIS.Note1: The terms “transmitter” and “sensor” in this document are

used in the same manner as “converter” and “fl owtube” respectively which have been used for our magnetic fl owmeter models.

Note2: This document covers the integral type fl owmeters and remote fl owtube (sensor) of the AXW magnetic fl ow-meter for sizes 500 to 1800 mm (20 to 72 in.). See the documents listed below regarding the sizes 25 to 400 mm and remote converters (transmitters) to be combined with. Especially when using remote converter AXFA11G, please note that the functional specifi cations are different from descriptions in this document.

Product DocumentNumberAXW Magnetic Flowmeter[Size: 500 to 1800 mm (20 to 72 in.)]Integral Type Flowmeter /Remote Flowtube

GS 01E25D11-01EN(this doucment)

AXW Magnetic Flowmeter[Size: 25 to 400 mm (1 to 16 in.)]Integral Type Flowmeter /Remote Sensor GS 01E24A01-01EN

AXW4A Remote TransmitterAX01C Signal CableAXFA11G Remote ConverterAXFC Signal Cable GS 01E20C01-01E

CONTENTS

GENERAL DESCRIPTION P.1FEATURES P.2GENERAL P.2CONSTRUCTION P.2

- Use, Construction P.2- Process Connection P.3- Lining Material, Electrode Material P.3- Electrode Construction P.3- Grounding Ring Material P.3- Grounding Ring Construction P.3- Gasket Material P.3- Non-wetted Part Material, Coating P.3- Electrical Connection, Wiring Terminal P.3- Installation Work P.3- Limitations on Specifi cation Selection P.3

FUNCTIONS (Integral Type) P.4CONFORMITY STANDARDS P.6PERFORMANCE P.7NORMAL OPERATING CONDITIONS P.8CAUTIONS ON SELECTION AND INSTALLATION P.8MODEL AND SUFFIX CODE P.11OPTIONAL SPECIFICATION CODE P.13TERMINAL CONFIGURATION AND WIRING P.16DIMENSIONAL DRAWINGS P.17SIZING DATA P.28ORDERING INFORMATION P.29RELATED INSTRUMENTS P.31REFERENCE STANDARD P.31TRADEMARKS P.31

Page 2: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

2<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN Apr. 27, 2017-00

nFEATURESlLineupExpansion

Up to the size 1000 mm, not only the remote type but also the integral type has been lined up. When placing the display on the measuring site, installation and cable laying costs can be reduced by adopting the integral type.

lMultipleInputsandOutputsMaximum four inputs/outputs of current, pulse, and status signals can be equipped.

lImprovedOperationandMonitoringFunctionOperation authority level setting for ensuring safety, process data trend display, display backlight flashing (Squawk) function, and data store / restore function with display unit internal memory or microSD card are available.

lImprovedMaintainabilityDiagnostic functions that contribute to preventive maintenance of the plant are equipped. Diagnosis of the device (built-in verification function) that can be executed without demounting from piping, and electrode adhesion diagnosis, and wiring connection diagnosis are available.

nGENERALMeasuringPrincipal:

By applying the occurrence of electromotive force proportional to the flow velocity when fluid moves in the magnetic field, the meter can measure the flow velocity of conductive liquid. It calculates the instan-taneous flow rate, integrated flow rate, etc. from the measured flow velocity.

SystemConfiguration:The meter consists of a sensor that detects the flow rate and a transmitter that amplifies, converts, and transmits the signal. Structurally, there is an integral type of sensor and transmitter, and a separate type which is separated. In the separated type, the signal cable for the flow signal and the excitation cable for the coil excitation are added to the constituent ele-ments.The sensor part and the transmitter part for the integral type are simply referred to as a sensor and a transmitter respectively. The integral type is also called as an integral type flowmeter. As for the com-ponents of separate type, they are also called as a remote sensor and a remote transmitter.Main Element of Sensor:

Wetted Part:Lining, Electrodes, Grounding ringsNote: Grounding rings are to take the reference electric

potential from the process fluid to measure the electromotive force from the process fluid, and they are fixed at two locations upstream and downstream of the flow. They are unnecessary when taking the reference potential from cus-tomer piping. Please also refer to ”Cautions on Selection and Installation”.

Non-wetted Part:Flanges, Housing, Excitation coil, Measuring tube

Main Element of Transmitter:Display unit, Setting keys, Amplifier unit (including I/Os and power supply unit)

nCONSTRUCTIONUse:

There are some types of constructions available for different purposes as shown in the table below.

Type Specification

General- purpose

Non explosion protection for the use in non-hazardous area. Integral or Remote type available.IP Protection Grade: IP66/67

Submersible

Temporary submersion is possible. Applica-ble to Remote Sensor only.Note: Signal and excitation cables, 30 m (98 ft)

length as standard, are wired, fixed with union-joint waterproof glands and urethane-potted in the terminal box of remote sensor when shipped.

IP Protection Grade: IP68 (Conforms to continuous immersion under the following test condition)

Test Condition: 50 m below the surface of the water, equiv-alent to 0.5 MPa hydraulic pressure, for one month. In case of bad condition such as sewage and seawater, this does not ap-ply. Also, please waterproof and protect the cable separately by conduit piping, etc.

Construction:Integral Type:

A flowmeter in integrated structure of a sensor and a transmitter.

Remote Type:A flowmeter in separated structure of a sensor and a transmitter, which are connected by a signal cable and an excitation cable. The excitation cable is to be supplied by customer except for submers-ible type.Combined Transmitter(*1)(*2):

AXW Remote Sensor sizes 500 to 1000 mm (20 to 40 in.) to be combined with (i) or (ii), and sizes 1100 to 1800 mm (44 to 72 in.) to be combined with (ii).(i) AXW4A Remote Transmitter(ii) AXFA11G Remote Transmitter*1: When changing the combination transmitter from (i) to (ii)

or vice versa, readjustment of the meter factor by actual flow calibration is necessary to ensure accuracy.

*2: For AXW4A and AXFA11G, please refer to the docu-ments listed on the front page. Also, please read “Cau-tions on Selection and Installation” in this document.

Maximum Cable Length:Signal Cable:(i) When combined with AXFA11G

AXFC Signal Cable Cable length maximum 200 m

(ii) When combined with AXW4A AX01C Signal Cable Cable length maximum 100 m

Page 3: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

3<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN Apr. 27, 2017-00

ProcessConnection:Process connections with the flanges below are available. For the linings and size ranges that can be combined with these connections, refer to “Model and Suffix Code” in this document.Flange:

ASME Class 150AWWA C207 Class DEN PN6, PN10, PN16JIS 10K, F12AS2129 Table D, Table EAS4087 PN16

LiningMaterial:Fluorocarbon PTFE lining Polyurethane rubber lining Natural hard rubber lining (with ethylene propylene diene rubber EPDM for sealing) Natural soft rubber lining

ElectrodeMaterial:JIS SUS316L, HASTELLOY C-276 equivalent (*)* : ASTM B574 UNS N10276 or ASME SB-574 UNS N10276

ElectrodeConstruction:Fluorocarbon PTFE lining: Internal insertion typePolyurethane rubber lining: External insertion typeNatural hard rubber lining: Internal insertion typeNatural soft rubber lining: Internal insertion type

GroundingRingMaterial:JIS SUS304, JIS SUSF304

GroundingRingConstruction:Ring flat plate, with a handle for installation (*)* : Grounding rings have a handle. Hook the pin attached to

the handle on the outer circumference of the flange and install it between the flowmeter and piping.

GasketMaterial:Note: The following is the material of gasket supplied with

flowmeter to be used between the lining sensor pipe and the grounding rings. However, necessary gaskets are mostly to be supplied by customer, and please refer to “Cautions on Selection and Installation” for recommended gaskets.

Gasket (in optional code GR2):Mixture of SBR and NR

Non-wettedPartMaterial:Sensor Terminal Box:

Aluminum alloy JIS ADC12Transmitter Housing:

Low copper aluminum alloy EN AC-43400Sensor Housing: Carbon steelFlange: Carbon steelMeasuring Pipe: Stainless steel

Coating:For General-purpose type (Integral type flowmeter / Remote sensor):

CoatedPart CoatingSpecificationSensor housing

Polyurethane resin solvent coatingSensor flanges

(for flange type)Terminal box (for remote sensor, incl. cover) Urethane curing type polyester

resin powder coatingTransmitter housing (incl. cover)

For Submersible type (Remote sensor):

CoatedPart CoatingSpecificationSensor housing

Non-tar epoxy resin solvent coatingSensor flanges

Terminal box (incl. cover)

Coating Color:Mint green (RAL color number 190 30 15) for General-purpose type Black (close to RAL color number 9011) for Sub-mersible type

ElectricalConnection:JIS G1/2 female ANSI 1/2 NPT female ISO M20 x 1.5 femaleElectrical Connection Direction:

For Integral Type Flowmeter and Remote Sensor, the cable entry direction can be specified when ordering from +90°, +180°, or -90°rotation (by optional code RA, RB, or RC), or can be changed by customer after delivery. However, it can not be changed after delivery when submersible type, or district heating and cooling / condensation-proof use (optional code DHC) is selected.

WiringTerminal:Remote Sensor (Terminals for flow signal and excita-tion current):

M4 Screw typeIntegral Type (Terminals for I/Os and power supply):

M4 Screw type (standard), or Clamp type (optional code CT)

InstallationWork:Remote Sensor: Grounding resistance 100 Ω or lessIntegral Type: Grounding resistance 10 Ω or lessNote: When lightning protection performance by the built-in

lightning protectors is not required, grounding resist-ance 100 Ω or less can be applied.

LimitationsonSpecificationSelection:Selectable structural specifications are limited between Use, Construction, Process Connection, Lining, Grounding Structure (Grounding Ring), and Electrical Connection specifications. In addition, the selectable sizes are determined by each specifica-tion of Lining and Process Connection. Please check them at “Model and Suffix Code” and also refer to “Cautions on Selection and Installation”.

Page 4: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

4<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

nFUNCTIONS(IntegralType)Note: For functional specifications in case of remote type,

please refer to the document of the remote transmitter to be combined with, which is listed on the front page.

DisplayandSetting:Parameter setting is possible without opening the cover of the housing by LCD display with three infra-red switches.Note: Parameter setting by setting tool such as HHT

(handheld terminal) and FieldMate (device adjustment / management software) is also possible.

Display:Construction:

Full dot matrix LCD, 64 x 128 dots, with backlight dot reversal display available

Display Language (*):Display Code 1:

English, French, German, Italian, Spanish, Portuguese, Russian and Japanese. The display languages are selectable and can be changed by customer.

Display Code 2:English and Chinese. The display languages are selectable and can be changed by customer.

* : The setting is English when shipped from factory.Display Screen Configuration:

Display Screen Item:Status display (icon), Time (necessary to set the time at power-on), Data display (max. four lines), Infrared switch operation status

Flow Rate Screen:Measured Data Screen (*1) or Online Trend Screen (*2) available. Update period selectable from 0.2, 0.4, 1, 2, 4, and 8 seconds.*1: Display up to 4 data points simultaneously with num-

bers, bar graphs, icons, or character strings. Specify up to 8 points of data and change display data with infrared switches or automatic scroll function (scroll period 2, 4, or 8 seconds). Selectable Data:

Flow rate (%), Flow velocity, Volumetric flow rate, Mass flow rate, Totalizer 1, Totalizer 2, Totalizer 3, Adhesion level, Current output 1, Tag number (maxi-mum 32 characters), Communication protocol

*2: Display one data as a trend graph. The display data can be changed with infrared switches or automatic scroll function (scroll period 2, 4, or 8 seconds) select-ing up to four data. Selectable Data:

Flow rate (%), Flow velocity, Volumetric flow rate, Mass flow rate, Totalizer 1, Totalizer 2, Totalizer 3, Current output 1

Alarm Screen:When an alarm occurs, the flow rate screen and the alarm screen are alternately displayed in the cycle (2, 4, or 8 seconds) linked with the flow rate screen update cycle. Select simple screen (single line display) or detail screen (with alarm counter-measure display).

NAMUR NE 107 Alarm Display Function:Based on NAMUR NE 107, alarms are classified and displayed as follows. It can also be set to hide.

F: FailureC: Function CheckS: Out of SpecificationM: Maintenance Required”

microSD Screen:Available when optional microSD is selected.Offline Trend Screen:

Data stored by the data logging function can be displayed on the trend screen. The selectable data is the same as that for the Online Trend Screen.

Display Backlight Blinking (Squawk) Function:Display backlight can be set to blink once or con-tinuously at 4-second cycle to identify the device.

Display Operation Authority:Display operation authority level against the parameters can be controlled by selecting from operator, maintenance, or specialist by passcode.Operator:

Only parameters related to display setting can be set.

Maintenance:Only parameters related to display setting and zero adjustment can be set.

Specialist:All parameters can be set.

CommunicationFunction:BRAIN Communication:

Communication Signal:Superimposed on the Current Output 1

Communication Line Condition:Load Resistance: 250 to 450 Ω (including cable resistance)Load Capacitance: 0.22 μF or lessLoad Inductance: 3.3 mH or lessInput Impedance of Communicating Device:

10 kΩ or more (at 2.4 kHz)Communication Distance:

Up to 1.5 km (0.93 miles), when polyethylene insulated PVC-sheathed cables (CEV cables) are used. Communication distance varies de-pending on the type of cable and wiring used.

Distance from Power Line:15 cm (6 in.) or more. (Parallel wiring should be avoided)

HART Communication:Protocol Version: HART 7Communication Signal:

Superimposed on the Current Output 1Communication Line Condition:

Load Resistance: 230 to 600 Ω (including cable resistance)

Input/OutputFunction:Input/Output Signal:

Input/Output up to four points can be selected from three types, type A, E, and G in the table.

Apr. 27, 2017-00

Page 5: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

5<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

Input/OutputTable:AXWSizes500to1000mm(20to40in.)IntegralTypeFlowmeter

TypeInput/OutputSignalforeachTerminal Code

I/O1 I/O2 I/O3 I/O4 BRAIN HART7

Type A Current Output 1 (Active)

Pulse/Status Output 1 (Passive) None None -D -E

Type E Current Output 1 (Active)

Pulse/Status Output 1 (Passive)

Status Input (No-voltage)

Pulse/Status Output 2 (Passive) -H -J

Type G Current Output 1 (Active)

Pulse/Status Output 1 (Passive)

Status Input (No-voltage)

Pulse/Status Output 2 (Active, without internal resistor)

-K -L

Input Signal:Status Input: Dry contact

Load Resistance:200 Ω or less (ON), 100 kΩ or more (OFF)

Output Signal:Current Output (Active): 4 to 20 mA DC signal

Load Resistance:750 Ω maximum, including cable resistance

Pulse / Status Output (Passive):Transistor contact output (open collector)Contact Capacity:

30 V DC (OFF), 200 mA (ON)Pulse Rate:

0.0001 to 10000 pps (pulse per second)Pulse Width:

0.05, 0.1, 0.5, 1, 20, 33, 50, 100, 200, 330, 500, 1000, or 2000 ms configurable

Frequency Output Range:1 to 12500 Hz

Pulse / Status Output (Active):Without Internal Resistor:(i) For Driving Electronic Counter

Load Resistance:1 kΩ or more

Internal Power Supply:24 V DC ±20%

Pulse Rate:0.0001 to 10000 pps (pulse per second)

Pulse Width:0.05, 0.1, 0.5, 1, 20, 33, 50, 100, 200, 330, 500, 1000, or 2000 ms configurable

Frequency Output Range:1 to 12500 Hz

(ii) For Driving Electromechanical CounterMaximum Current:

150 mAInternal Power Supply:

24 VDC ±20%Pulse Rate:

0.0001 to 2 pps (pulse per second)Pulse Width:

20, 33, 50, or 100 ms configurableFlowCalculationFunction:

Excitation Method: Pulsed DC Excitation (for sizes 500 to 1800 mm, 20 to 72 in.)

Span Setting:Span flow can be set in units such as volume flow rate, mass flow rate, time, or flow rate value. The velocity unit can also be set.Volume Flow Rate Unit:

kcf, cf, mcf, Mgal (US), kgal (US), gal (US), mgal (US), kbbl (US)*, bbl (US)*, mbbl (US)*, μbbl (US)*, Ml (megaliter), m3, kl (kiloliter), l (liter), cm3 * : “US Oil” or “US Beer” can be selected.

Apr. 27, 2017-00

Mass Flow Rate Unit:klb (US), lb (US), t (ton), kg, g

Velocity Unit:ft, m (meter)

Time Unit:s (sec), min, h (hour), d (day)

Damping Function (63% response):Can be set for each measurement value of flow velocity, volume flow rate, and mass flow rate.Output Damping:

For each measured value, the time constant for instantaneous value output and the time constant for totalization / pulse output can be individually set. Time constant 0.1 to 200.0 seconds (shipped with 3.0 seconds). In the case of piston pump etc., it is possible to measure pulsatile flow up to 1 Hz with output damping 0.1 sec. However, note that decreasing damping time generally increases output fluctuation.

Display Damping:A common time constant can be set for each screen display value of each measurement value. Time constant 0.0 to 200.0 seconds (shipped with 0.0 seconds).

Current Output:Current signal (4 to 20 mA DC) proportional to instantaneous flow rate is outputted.

Pulse Output:The totalized value of the flow rate is converted into the number of pulses converted by the pulse rate, and is outputted.

Frequency Output:Frequency signal (Duty 50%) proportional to the instantaneous value of the flow rate is outputted. Output terminal is shared with pulse output.

Totalization Function:Three independent totalizers can be allocated inde-pendently, including the start and stop of integra-tion, for each measured value of volume flow rate and mass flow rate.Totalization Type:

Forward / reverse difference flow totalization, Absolute value totalization, Forward direction totalization, Reverse direction totalization

Totalization Display:Select from actual flow rate display or count value display scaled by counter conversion rate.

Low-cut Function (*):Cut below the set actual flow rate value for each flow rate of current output, pulse output, and fre-quency output. It is independent for current output, common for pulse output and frequency output.* : When “Forward and Reverse Flow Measurement” or

“Absolute Range” is used, cut below the set actual flow rate value against the absolute value of the measured value.

Page 6: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

6<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

OutputProcessingFunction:Multi-range Function:

Flow range can be switched to 2 ranges by status input or automatic switching. By status output, it is possible to identify in what range the measurement is being measured, and the status is also displayed on the display.

Forward and Reverse Flow Measurement:Flow rate measurement in both forward and re-verse directions is possible. By status output, it is possible to identify in which direction the measure-ment is being performed, and the status is also displayed on the display.

Absolute Range:With 12 mA as flow rate zero, measurements in the forward (12 to 20 mA) and reverse (4 to 12 mA) directions are possible in a single range.

Totalization Switch:Status signal is outputted when the totalized value becomes equal to or larger than the set value.

Preset Totalization:By parameter setting or status input, the totalized value is preset to zero or a set value.

0% Signal Lock:With status input, the current output is forcibly fixed to 0%. Instantaneous flow rate display, pulse output, and flow rate totalization continue.

AlarmFunction:Alarm Configuration:

Alarms are classified into system alarm (device failure), process alarm, setting alarm, and warning. Alarm output availability can be selected for each item.

Current Output at Alarm Occurrence:The current output at alarm occurrence is arbitrarily selected from less than 2.4 mA, 3.8 mA fixed, 4 mA fixed, 20.5 mA fixed, more than 21.6 mA, meas-ured value, or HOLD.

Alarm Countermeasure Indication:A specific countermeasure method can be dis-played on the display when an alarm occurs.

Alarm Type:System Alarm:

CPU failure, A/D converter failure, Sensor coil circuit break (open), Sensor coil short circuit

Process Alarm:Input signal error (signal overflow), Sensor empty pipe, Electrode adhesion (of insulator)

Setting Alarm:Detect inconsistency in parameter setting

Warning:Warning in a state where measurement can be continued.

Alarm History:Keep history of up to 4 alarms.

VerificationFunction:Function to check the soundness of the device itself. Check the magnetic circuit, excitation circuit, arithmetic processing circuit, etc. offline (i.e. flow measurement function stopped) and display the result without demounting the device from piping.

DataManagementFunction:Store / Restore of Parameters:

Main parameters can be stored up and restored using nonvolatile memory of display unit or optional microSD card. The restore can also be used for copying parameters to another device (except for parameters under unmatched specification for the devices).

Data Logging Function:By using an optional microSD card, it is possible to log up to 4 process data at the same time. In ad-dition to displaying the logged results on the trend screen, it is also possible to connect the microSD card to a PC and retrieve the data.Logging Cycle:

1 second, 10 seconds, 30 seconds, 1 minute, 5 minutes, 30 minutes, 1 hour

Logging Time:10 minutes, 30 minutes, 1 hour, 3 hours, 12 hours, 24 hours, 72 hours, 240 hours

Logging Data:Flow velocity, Volume flow rate, Mass flow rate, Adhesion level, Electrode potential (A, B), Flow signal peak value

Data Security During Power Failure:Protection of data, such as parameters and inte-grated values, by nonvolatile memory at power failure.

Factory Default Parameter Restore:It is possible to restore the parameters to the val-ues that were set at the time of factory shipment.

LightningProtection:Built-in lightning protector for input / output termi-nals and power supply terminal.

Test Standard: IEC61000-4-5Test Method:

Series mode 1 kV / Common mode 2 kVSurge waveform 8/20 μS

nCONFORMITYSTANDARDSEMC:

EN61326-1 Class A, Table 2 (For use in industrial locations)EN61326-2-3EN61000-3-2 Class AEN61000-3-3

Apr. 27, 2017-00

Page 7: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

7<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

nPERFORMANCEAccuracy(PulseOutput):

0.35% of rate for sizes 500 mm (20 in.) to 1000 mm (40 in.)0.5% of rate for sizes 1100 mm (44 in.) to 1800 mm (72 in.)

Sizemm(in.)

FlowVelocityVm/s(ft/s) Accuracy

500 (20) to 1000 (40)

V < 0.3 (1) ±2.0 mm/s0.3 (1) ≤ V ≤ 10 (33) ±0.35% of rate ±1.0 mm/s

1100 (44) to 1800 (72)

V < 0.3 (1) ±3.0 mm/s0.3 (1) ≤ V < 1 (3.3) ±0.4% of rate ±1.8 mm/s1 (3.3) ≤ V ≤ 10 (33) ±0.5% of rate ±1.0 mm/s

Forsizes500mm(20in.)to1000mm(40in.)Pulse Output Accuracy

0.0

F01.ai

0.2

0.4

0.6

0.8

1.0

1.2

0 1 2 3 4 5 6 7 8 9 10V [m/s]

% of rate

Forsizes1100mm(44in.)to1800mm(72in.)Pulse Output Accuracy

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 1 2 3 4 5 6 7 8 9 10V [m/s]

% of rate

F02.ai

Note: - The accuracy above is the result of calibration test at our water flow facility before shipment. It is defined by the integrated value of the pulse output. As for the current output accuracy, add ±8 μA (±0.05% of span) to the ac-curacy above.

- Calibration takes place at reference conditions as below. Medium: Water, Density: 0.9 to 1.1 kg/l Medium temperature: 10 to 35°C (50 to 95°F) (Average temperature 22.5°C (72.5°F)) Ambient temperature: 10 to 35°C (50 to 95°F) Process pressure (absolute): 0.1 to 0.2 MPa (15 to 29 psi)

- Reference Standards: JIS B 7554, ISO 4185, ISO 5168, ISO 9104, BS EN 29104

Repeatability:±0.2% of rate (V ≥ 1 m/s (3.3 ft/s))±0.1% of rate ± 1 mm/s (V < 1 m/s (3.3 ft/s))

MeasurementRange:Minimum Span Velocity:

0.1 m/s (for sizes 500 to 1000 mm, 20 to 40 in.)0.3 m/s (for sizes 1100 to 1800 mm, 44 to 72 in.)

Maximum Span Velocity:10 m/s (for sizes 500 to 1800 mm, 20 to 72 in.)Note: Please refer to the chart in “Sizing Data”, and

description on the Span Flow Rate in “Ordering Information”.

PowerConsumption:Integral Type: 13 WRemote Type: 13 W (with AXW4A Transmitter)

20 W (with AXFA11 Transmitter)Note: The power consumption is the same as above regard-

less of the communication and I/O type.

InsulationResistance:Integral Type:

Between power supply terminals and ground terminal:

100 MΩ/500 V DCBetween power supply terminals and input /output terminals:

100 MΩ/500 V DCBetween ground terminal and input/output termi-nals:

20 MΩ/100 V DC or 125 V DCBetween input/output terminals:

20 MΩ/100 V DC or 125 V DCRemote Sensor:

Between signal terminals:100 MΩ/500 V DC

Between signal terminals and common terminal:100 MΩ/500 V DC

Between excitation current terminal and signal / common terminals:

100 MΩ/500 V DCWithstandVoltage:

Integral Type:Between power supply terminals and ground terminal:

1400 V AC for 2 secondsBetween power supply terminals and input /output terminals:

1400 V AC for 2 seconds

Apr. 27, 2017-00

Page 8: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

8<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

nNORMALOPERATINGCONDITIONSAmbientTemperature:

–10 to +60°C (+14 to +140°F)Note: Minimum temperature should also be limited according

to minimum fluid temperature of sensor’s specification. Refer to description of “Fluid Temperature and Pres-sure”. Contact Yokogawa office for lower temperature.

AmbientHumidity:0 to 100%Note: Lengthy continuous operation at 95% or more is not

recommended.

PowerSupply:Power Supply Code 1:

AC Type:Rated Power Supply: 100 to 240 V AC, 50/60 HzOperating Voltage Range: 80 to 264 V AC

DC Type:Rated Power Supply: 100 to 120 V DCOperating Voltage Range: 90 to 130 V DC

Power Supply Code 2:AC Type:

Rated Power Supply: 24 V AC, 50/60 HzOperating Voltage Range: 20.4 to 28.8 V AC

DC Type:Rated Power Supply: 24 V DCOperating Voltage Range: 20.4 to 28.8 V DC

SupplyVoltageandPowerSupplyCableLengthforPowerSupplyCode2:

Allo

wab

le c

able

leng

th m

(ft)

F03.ai

Cable cross section area: 1.25 mm2

Cable cross section area: 2 mm2

Usable voltage range (V)22 24 26 28 3020 28.8

338 (1100)

603 (1970)700 (2290)

600 (1960)

500 (1640)

400 (1310)

300 (980)

200 (650)

100 (320)

0

FluidConductivity:Size 500 to 1000 mm (20 to 40 in.):

20 μS/cm or largerSize 1100 to 1800 mm (44 to 72 in.):

50 μS/cm or largerFluidTemperatureandPressure:

Note: The following values show maximum allowable fluid pressure for the sensor. Further fluid pressure should also be limited according to flange rating.

LiningMaterial FluidTemperature FluidPressureFluorocarbon PTFE

-10 to 120°C (14 to 248°F)

0 to 1 MPa (0 to 145 psi)

Natural hard rubber

-5 to 80°C (23 to 175°F)

0 to 1 MPa (0 to 145 psi)

Natural soft rubber

-10 to 70°C (14 to 158°F)

0 to 1 MPa (0 to 145 psi)

Polyurethane rubber

-10 to 40°C (14 to 104°F)

-0.1 to 1 MPa (-14.5 to 145 psi)

nCAUTIONSONSELECTIONANDINSTALLATION

CombinedTransmitter:If it is considered that the flow noise in the fluid could be large because of low conductivity, conductivity nonuniformity, or high concentration slurry, etc., it is recommended to use a remote sensor in combination with AXFA11G (refer to GS 01E20C01-01E).

Lining:PTFE Lining:

It is excellent in chemical resistance and suitable for general chemical fluids.

Polyurethane Lining:It has abrasion resistance and suitable for low slurry fluid of water, water-based solution, muddy water, or seawater.

Natural Hard Rubber Lining:It has chemical resistance and suitable for acid / alkali fluid of low concentration, and also wastewa-ter / sewage.

Natural Soft Rubber Lining:It is a material that can reduce wear of the lining due to slurry mixed fluid. If the concentration of slurry is high, separate measures are required for the electrode part, so please consult us.

SelectionofGroundingRing:The grounding ring is optional. It is unnecessary to use it for metal piping which has no lining. In that case, please connect the piping and the sensor flange part with grounding wire supplied by customer (see the figure below). Be sure to select the ground-ing ring when installed at resin or lining piping.

F04.ai

InstallingPTFESensor:When installing PTFE lining sensor to the piping and tightening it, be careful not to apply uneven tension and torque to the PTFE. It is recommended to install the PTFE lining sensor with grounding rings or with short pipes at both upstream and downstream side fixed beforehand.

MountingofFlowmetersandRequiredLengthsofStraightRuns:

Based on JIS B 7554 “Electromagnetic Flowmeters” and our piping condition test data, we recommend the piping conditions as shown in the following fig-ures. This is not always enough when the piping line incorporates multiple conditions at the same time. When installing two or more magnetic flowmeters on a single pipe, provide a run of at least 5D between them.

Apr. 27, 2017-00

Page 9: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

9<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

F05.ai

D: Sensor SizeGate valve fully open

5D or more2D

or more

Reducer pipe

Expander pipe

0 is allowable. 0 is allowable. 10D or more 2D or more

10D or more

Tee 90-degree bendVarious valves

0 is allowable.5D or more 0 is allowable.5D or more2D

or more

Requiredstraightruns*1: Do not install anything in the vicinity that may interfere

with the magnetic field, induced signal voltages, or flow velocity distributions of the flowmeter.

*2: A straight run may not be required on the downstream side of the flowmeter. However, if a downstream valve or other fitting causes irregularity or deviation in flows, provide a straight run of 2D to 3D on the downstream side.

*3: The valves shall be mounted on the downstream side so that deviated flows do not occur in the sensor and to avoid startup from an empty condition.

*4: In case the piping conditions are compounded, install on the straight pipe section where the upstream part is sufficiently rectified.

FluidConductivityChange:Do not install the flowmeter where fluid conductivity tends to become uneven. If chemicals are fed near the upstream side of a magnetic flowmeter, they may affect the flow rate indication. To avoid this situation, it is recommended that the chemical feed ports be located on the downstream side of the flowmeter. If it is unavoidable that chemicals must be fed on the upstream side, provide a sufficient length of straight run (approximately 50D) to ensure the proper mixture of fluids.

MountingPositions:1. Pipe fully filled with liquid

It is essential that pipes remain fully filled at all times, otherwise flow rate indication may be af-fected and measurement errors may occur.Piping shall be designed so as to maintain the sen-sor filled with fluids.Vertical mounting is effective in such cases as when fluids tend to separate or solid matter may precipitate.When employing vertical mounting, direct the fluid from the bottom to the top to ensure that the pipe remains fully filled.

hh>0

h>0h

F06.ai

(Incorrect)(Correct)

(Incorrect)(Correct)

MountingPositions

2. Avoiding Air BubblesIf air bubbles arise in the pipe, flow rate indication may be affected and measurement errors may occur.In cases where the fluid contains air bubbles, piping must be designed to prevent them from ac-cumulating in the magnetic flowmeter sensor.If a valve exists near the sensor, try to mount the sensor on the valve’s upstream side in order to prevent a possible reduction of pressure inside the pipe, thereby avoiding the possibility of air bubbles.

F07.ai

Valve

(Incorrect)(Correct)

(Incorrect)

(Correct)

AvoidingAirBubbles

3. Mounting OrientationIf electrodes are perpendicular to the ground, air bubbles near the top or precipitates at the bottom may cause measurement errors.Ensure that the terminal box of the sensor is mounted above the piping to prevent water from entering.

F08.ai

Air bubble

Electrode Electrode Precipitate

(Incorrect)

(Correct)

(Incorrect)

Water can seep into the terminal box.

MountingOrientation

GasketsandGroundingRings:Necessary gaskets for piping connection are as be-low depending on the choice of grounding rings.Use sheet gaskets designed to fit for flange standard. The GF type-1 gaskets by JIS G 3443-2 should be used for the JIS F12 flange models in sizes 1100 mm (44 in.) and above. In this case, the gasket groove is required on the customer pipe flanges.The thickness of gasket should be 2 mm (0.08 in.) to 5 mm (0.2 in.) for sizes up to 1000 mm (40 in.), and 5 mm (0.2 in.) or more for larger sizes. The type of gasket should be a kind of soft rubber, or its equiva-lent in hardness.

1. Standard (no grounding rings)

Gaskets A supplied by customer

Customerpipe

Customerpipe

A A

F09.ai

When using the GF type-1 gaskets, the gasket groove is required as mentioned above.

Apr. 27, 2017-00

Page 10: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

10<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

2. With optional grounding rings (code GR1)

Optional grounding rings

Gaskets A and B supplied by customer

Customerpipe

Customerpipe

A BB A

F10.ai

It is recommended to use the same gasket for A and B. Both gaskets A and B are to be supplied by customer.When polyurethane or natural soft rubber lining, the gaskets B are not necessary.

3. With optional grounding rings (code GR2)

Customerpipe

Optional grounding rings with integrated gaskets B included

Gaskets A supplied by customer

Customerpipe

F10_02.ai

A A

BB

This is available for the models with process con-nection JIS F12 (JIS 75M) in sizes 1100 mm (44 in.) and above. Only gaskets A are to be supplied by customer.The grounding rings are installed and locked onto the sensor with gaskets B when shipped from factory.

Apr. 27, 2017-00

Page 11: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

11<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

nMODELANDSUFFIXCODEl ForProcessConnectionsotherthanJISF12(JIS75M)

Model SuffixCode Description AvailableSize/ModelAXW500 Size 500 mm (20 in.) Integral Flowmeter / Remote FlowtubeAXW600 Size 600 mm (24 in.) Integral Flowmeter / Remote FlowtubeAXW700 Size 700 mm (28 in.) Integral Flowmeter / Remote FlowtubeAXW800 Size 800 mm (32 in.) Integral Flowmeter / Remote FlowtubeAXW900 Size 900 mm (36 in.) Integral Flowmeter / Remote FlowtubeAXW10L Size 1000 mm (40 in.) Integral Flowmeter / Remote FlowtubeAXW12L Size 1200 mm (48 in.) Remote FlowtubeAXW14L Size 1400 mm (56 in.) Remote FlowtubeAXW16L Size 1600 mm (64 in.) Remote FlowtubeAXW18L Size 1800 mm (72 in.) Remote FlowtubeUse G General-purpose type

W Submersible type Only for Remote FlowtubeConverter, Communica-tion and I/O

- : D, H, K Integral Flowmeter with 4 to 20 mA DC Output BRAIN and I/O (Type A, E, G. See separate table)

- : E, J, L HART 7 and I/O (Type A, E, G. See separate table)

-N Remote Flowtube for Combined Use with AXFA11-W Remote Flowtube for Combined Use with AXW4A

Power Supply 1 100 to 240 V AC / 100 to 120 V DC Not available for Remote Flowtube2 24 V AC / DC Not available for Remote FlowtubeN None (Remote Flowtube) Only for Remote Flowtube

Lining (*1) F Fluorocarbon PTFE See “Process Connection”H Natuarl Hard Rubber See “Process Connection”D Natuarl Soft Rubber See “Process Connection”U Polyurethane Rubber See “Process Connection”

Electrode Material (*1) L JIS SUS316L (AISI 316L SS Equivalent)H HASTELLOY C-276 Equivalent

Electrode Structure 1 Non-replaceableGrounding Structure (*2) N None (*3), available as optional feature (GR1)Process Connection (*4)

-CA1ASME B16.5 Class 150 Flange (Carbon Steel) 500 mm (20 in.) and 600 mm (24 in.)

for lining code F/H/D/U

ASME B16.47 Series A Class 150 Flange (Carbon Steel) 700 mm (28 in.) to 1000 mm (40 in.) for lining code F/H/D/U

-CB1 AWWA C207 Class D (Carbon Steel)700 mm (28 in.) to 1000 mm (40 in.) for lining code F/H/D/U 1200 mm (48 in.) for lining code H

-CEJ EN1092-1 PN6 Flange (Carbon Steel)1200 mm (48 in.) to 1800 mm (72 in.) for lining code H-CEK EN1092-1 PN10 Flange (Carbon Steel)

(fluid pressure up to 0.6 MPa)

-CE1 EN1092-1 PN10 Flange (Carbon Steel) (fluid pressure up to 1 MPa)

500 mm (20 in.) to 1000 mm (40 in.) for lining code F/H/D/U 1200 mm (48 in.) to 1800 mm (72 in.) for lining code H

-CE2 EN1092-1 PN16 Flange (Carbon Steel)(fluid pressure up to 1 MPa) 500 mm (20 in.) to 1000 mm (40 in.)

for lining code F/H/D/U-CJ1 JIS B2220 10K Flange (Carbon Steel)-CS1 AS2129 Table D (Carbon Steel) 500 mm (20 in.) to 1000 mm (40 in.)

for lining code F/H/D/U 1200 mm (48 in.) for lining code H

-CS2 AS2129 Table E (Carbon Steel)-CT1 AS4087 PN16 (Carbon Steel)

Lay Length N StandardElectrical Connection -0 JIS G1/2 female

-2 ANSI 1/2 NPT female Not available for Submersible type-4 ISO M20 x 1.5 female Not available for Submersible type

Indicator 1 With Indicator (English, Multi-language) Not available for Remote Flowtube2 With Indicator (English, Chinese) Not available for Remote FlowtubeN Without Indicator / Remote Flowtube

Calibration B StandardOptional Specifications / Refer to optional specification table.

*1: Users must consider the characteristics of selected wetted parts material and influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the instrument itself can be damaged and that fragments from the instrument can contaminate the user’s process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*2: Select optional grounding rings (code GR1) if necessary. For example, grounding rings are necessary for plastic piping.*3: “None” is applicable only for metal piping and wiring for grounding will be necessary so that the electric potentials between flowtube

and piping flange should be the same.*4: Contact Yokogawa office for ISO flange connection.

Apr. 27, 2017-00

Page 12: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

12<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

l ForProcessConnectionJISF12(JIS75M)

Model SuffixCode Description AvailableSize/ModelAXW500 Size 500 mm (20 in.) Integral Flowmeter / Remote FlowtubeAXW600 Size 600 mm (24 in.) Integral Flowmeter / Remote FlowtubeAXW700 Size 700 mm (28 in.) Integral Flowmeter / Remote FlowtubeAXW800 Size 800 mm (32 in.) Integral Flowmeter / Remote FlowtubeAXW900 Size 900 mm (36 in.) Integral Flowmeter / Remote FlowtubeAXW10L Size 1000 mm (40 in.) Integral Flowmeter / Remote FlowtubeAXW11L Size 1100 mm (44 in.) Remote FlowtubeAXW12L Size 1200 mm (48 in.) Remote FlowtubeAXW13L Size 1350 mm (54 in.) Remote FlowtubeAXW15L Size 1500 mm (60 in.) Remote FlowtubeAXW16L Size 1600 mm (64 in.) Remote FlowtubeAXW18L Size 1800 mm (72 in.) Remote FlowtubeUse G General-purpose type

W Submersible typeConverter, Communica-tion and I/O

- : D, H, K Integral Flowmeter with 4 to 20 mA DC Output BRAIN and I/O (Type A, E, G. See separate table)

- : E, J, L HART 7 and I/O (Type A, E, G. See separate table)

-N Remote Flowtube for Combined Use with AXFA11-W Remote Flowtube for Combined Use with AXW4A

Power Supply 1 100 to 240 V AC / 100 to 120 V DC Not available for Remote Flowtube2 24 V AC / DC Not available for Remote FlowtubeN None (Remote Flowtube) Only for Remote Flowtube

Lining (*1) U Polyurethane RubberElectrode Material (*1) L JIS SUS316L (AISI 316L SS Equivalent)

H HASTELLOY C-276 EquivalentElectrode Structure 1 Non-replaceableGrounding Structure (*2) N None (*3), available as optional feature (GR1 or GR2)Process Connection -CG1 JIS F12 (JIS 75M) Flange (Carbon Steel)Lay Length N StandardElectrical Connection -0 JIS G1/2 female

-2 ANSI 1/2 NPT female Not available for Submersible type-4 ISO M20 x 1.5 female Not available for Submersible type

Indicator 1 With Indicator (English, Multi-language)2 With Indicator (English, Chinese)N Without Indicator / Remote Flowtube

Calibration B StandardOptional Specifications / Refer to optional specification table.

*1: Users must consider the characteristics of selected wetted parts material and influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the instrument itself can be damaged and that fragments from the instrument can contaminate the user’s process fluids.

Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*2: Select optional grounding rings (code GR1 or GR2) if necessary. For example, grounding rings are necessary for plastic piping. The code GR1 is optional only for sizes 500 mm (20 in.) to 1000 mm (40 in.). The code GR2 is optional only for sizes 1100 mm (44 in.) to 1800 mm (72 in.).

*3: “None” is applicable only for metal piping and wiring for grounding will be necessary so that the electric potentials between flowtube and piping flange should be the same.

Apr. 27, 2017-00

Page 13: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

13<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

l Details:CommunicationandI/O

Communicationand

I/OCodeSpecification

NumberofInputandOutput

CurrentOutput(Active)

Pulse/StatusOutput(Passive)

StatusInput(No-voltage)

Pulse/StatusOutput

(Active,with-outinternalresistor)

-D BRAIN and I/O (Type A)1 1 – –

-E HART 7 and I/O (Type A)

-H BRAIN and I/O (Type E)1 2 1 –

-J HART 7 and I/O (Type E)

-K BRAIN and I/O (Type G)1 1 1 1

-L HART 7 and I/O (Type G)

nOPTIONALSPECIFICATIONSCODEl Application,Usage,andOperatingFunction

: Available – : Not available

Item Specifications

ApplicableModel

CodeIntegralType

RemoteFlowtubeGeneral Submersible

AXW***G-(:D,H,K,E,J,L)

AXW***G-(:N,W) AXW***W

DC Noise Cut Circuit (for electrolytic bath)

Built-in DC noise cut circuit. It works effectively when the fluid conductivity is 50 μS/cm or more. Empty pipe detection, elec-trode adhesion diagnosis, electrode potential measurement, and wetted resistance measurement function can not be used.

– – ELC

For District Heating and Cooling or Condensation-proof

Urethane resin potting is applied in the terminal box of a remote sensor. Select JIS G1/2 for the electrical connections. 30-meter length signal and excitation cables are pre-wired and water-proof glands with union joints are attached at factory.

– – DHC

User-specified Signal and Excitation Cable Length

Change the length of signal cable and excitation cable pre-wired for a remote sensor of Submersible type or one with optional code DHC. Specify the cable length in the “” part with the numerical value 3 digits. It is 1 m unit up to 5 m (001, 002, 003 ...), 5 m units for 5 m or more (005, 010, 015 ...), and 10 m units for 100 m or more (100, 110, 120 ...). The maximum cable length is 100 m in combination with the AXW4A transmitter, and 200 m in combination with the AXFA11 transmitter. If not with this optional code, a 30-meter length cable as standard is pre-wired.

– L

Mass Unit Setting

The flow rate calculation is performed in mass unit. In addi-tion to fluid density, specify span flow rate, pulse weight, and totalization weight in mass unit. For remote sensor, specified parameters are set in the transmitter that is ordered in com-bination. Please refer to “Ordering Information” for specifying procedures.

MU

Signal Down on Failure

Set the current output signal as follows when shipped.Output signal at CPU failure or alarm occurrence:

2.4 mA (-10 %) or lessNote: The standard setting is 21.6 mA (110%) or more at CPU

failure or alarm occurrence.

– – C1

Signal Down on Failure (NAMUR NE 43 Compliant)

Set the current output signal range as follows when shipped.- Output signal limits: 3.8 to 20.5 mA - Output signal at CPU failure or alarm occurrence:

2.4 mA (–10%) or less

– – C2

Signal Up on Failure (NAMUR NE 43 Compliant)

Set the current output signal range as follows when shipped.- Output signal limits: 3.8 to 20.5 mA - Output signal at CPU failure or alarm occurrence:

21.6 mA (110%) or more

– – C3

microSD Card

A microSD card slot is added to the display unit, and a microSD card (capacity 1 GB, format FAT 16) is inserted. Select this op-tion when using parameter store / restore function, and/or data logging function.

– – MC

Transmitter Wiring Terminal Clamp Type

Change the power supply and input / output wiring terminal of in-tegral type flowmeter from standard M4 screw-type to clamp type. – – CT

Apr. 27, 2017-00

Page 14: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

14<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

l GroundingRing,TagPlate,DirectionofElectricalConnection,WaterproofGland: Available – : Not available

Item Specifications

ApplicableModel

CodeIntegralType

RemoteFlowtubeGeneral Submersible

AXW***G-(:D,H,K,E,J,L)

AXW***G-(:N,W) AXW***W

Grounding Rings (*1) JIS SUS304 (AISI 304 SS Equivalent), a set of two rings GR1

Grounding Rings (*2) JIS SUSF304 (AISI 304 SS Equivalent), a set of two rings with gaskets “B”. GR2

Stainless Steel Tag Plate

Hang the pendant type tag plate (stainless steel 304) from the neck (for integral type and remote sensor), or screw it (for remote transmitter). Select this option when necessary in addi-tion to that on the nameplate, on which the Tag No. is inscribed as standard. Plate size (Height x Width): Approx. 12.5 x 40 mm (4.92 x 15.7 in.)

SCT

Direction Change of Electrical Connection (*3)

Rotate the transmitter part of integral type or the terminal box of remote sensor by +90° and change the direction of electrical connection.

RA

Rotate the transmitter part of integral type or the terminal box of remote sensor by +180° and change the direction of electrical connection.

RB

Rotate the transmitter part of integral type or the terminal box of remote sensor by -90° and change the direction of electrical connection.

RC

G3/4 Female Water-proof Glands (Type W)

Waterproof glands for G3/4 conduits or flexible tubes for remote sensor are attached to the electrical connections. Avail-able only for JIS G1/2 electrical connections.

– – EW

Waterproof Glands (Type G)

Waterproof glands for remote sensor are attached to the electrical connections. Available only for JIS G1/2 electric con-nections.

– – EG

Waterproof Glands with Union Joints (Type U)

Waterproof glands with union joints for remote sensor are at-tached to the electrical connections. Available only for JIS G1/2 electric connections.

– – EU

Waterproof Glands (Type G2)

Two waterproof glands and one blanking plug for the electrical connection are attached for the integral type flowmeter. Select JIS G1/2 female thread as electrical connection.

– – EG2

Waterproof Glands (Type G3)

Three waterproof glands for the electrical connection are at-tached for the integral type flowmeter. Select JIS G1/2 female thread as electrical connection.

– – EG3

Waterproof Glands (Type U2)

Two waterproof glands with union joints and one blanking plug for the electrical connection are attached for the integral type flowmeter. Select JIS G1/2 female thread as electrical connec-tion.

– – EU2

Waterproof Glands (Type U3)

Two waterproof glands with union joints for the electrical con-nection are attached for the integral type flowmeter. Select JIS G1/2 female thread as electrical connection.

– – EU3

Plastic Glands (Type P2)

Two plastic glands and one blanking plug for the electrical con-nection are attached for the integral type flowmeter. Select JIS G1/2 female thread as electrical connection.

– – EP2

Plastic Glands (Type P3)

Three plastic glands for the electrical connection are attached for the integral type flowmeter. Select JIS G1/2 female thread as electrical connection.

– – EP3

*1: This is not available for models with process connection JIS F12 (JIS 75M) of sizes 1100 mm (44 in.) to 1800 mm (72 in.). Refer to “CAUTIONS ON SELECTION AND INSTALLATION” on necessary gaskets.

*2: This is available only for models with process connection JIS F12 (JIS 75M) of sizes 1100 mm (44 in.) to 1800 mm (72 in.). Refer to “CAUTIONS ON SELECTION AND INSTALLATION” on necessary gaskets.

*3: Refer to “ORDERING INFORMATION” for the image of the rotation.

Apr. 27, 2017-00

Page 15: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

15<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

l MaterialCertificate,CalibrationCertificate,FlowCalibration,HydrostaticTest,etc.: Available – : Not available

Item Specifications

ApplicableModel

CodeIntegralType

RemoteFlowtubeGeneral Submersible

AXW***G-(:D,H,K,E,J,L)

AXW***G-(:N,W) AXW***W

Material Certificate Material certificates are provided for pipe, electrodes, flanges, and also optional grounding rings when specified. M01

Calibration Certificate

Level 2: The Declaration and the Calibration Equipment List are issued. L2

Level 3: The Declaration and the Primary Standard List are issued. L3

Level 4: The Declaration and the Yokogawa Measuring Instru-ments Control System are issued. L4

Five-point Calibra-tion in User-specified Span

With the customer’s specified span, the actual flow inspec-tion of 5 points around 0, 25, 50, 75, and 100% is performed. Instead of the flow inspection at the standard flow rate of 2 m/s, the result of flow inspection with the customer specified span is described in a test certificate (QIC). For specifiable spans, please refer to “Ordering Information”.

SC

Hydrostatic Test

The water pressure depending on the process connection is applied to the lining (measuring pipe) for 10 minutes to check that there is no leakage, and the result is described in a test certificate (QIC).

Process Connection: Water Pressure:EN PN6, EN PN10 (Code CEK) 0.9 MPaASME Class 150, EN PN10 (Code CE1), EN PN16 1.5 MPaJIS 10K, JIS F12 (JIS 75M) 1.5 MPaAS2129 Table E, AS4087 PN16 1.5 MPaAWWA C207 Class D 1.25 MPaAS2129 Table D 1.05 MPa

T01

Apr. 27, 2017-00

Page 16: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

16<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

nTERMINALCONFIGURATIONANDWIRING

RemoteFlowtube:<To be wired to Remote Transmitter/Converter>

F11.ai

Flow Signal Output

Excitation Current Input

Description

Protective Grounding(Outside of the terminal box)

Terminal SymbolABC

EX1EX2

Note: When submersible type or optional code DHC is selected, waterproof glands with union joints and a 30-meter length cable as standard are attached.

Note: For the terminal configuration and wiring of remote transmitters AXW4A or AXFA11G, refer to the Gen-eral Specifications listed on the front page.

Apr. 27, 2017-00

IntegralTypeFlowmeter:<To be wired to Power Supply and I/Os>

F12.ai

M4 Screw Type

Clamp Type

Terminal Symbol

N/-L/+

I/O4 -I/O4 +I/O3 -I/O3 +I/O2 -I/O2 +I/O1 -I/O1 +

Input/Output

Functional Grounding

Shorting Screw(Need to be fixed for normal operation)

Protective Grounding(Inside and outside of the terminal box)

Description

Power Supply

RecommendedCableforExcitation,PowerandInput/Output:

JIS C 3401 control cable equivalentJIS C 3312 power cable equivalent14 AWG Belden 8720 equivalentOuter Diameter:

With no gland option:6.5 to 12 mm (0.26 to 0.47 in.)

With waterproof gland option (code EG, EG, EU, EU, EW):

For excitation cable: 10.5 or 11.5 mm (0.41 or 0.45 in.)

For power and output cable: 7.5 to 12 mm (0.3 to 0.47 in.)

With plastic gland option (code EP, EP):6 to 12 mm (0.24 to 0.47 in.)

Nominal Cross Section:Single wire: 0.5 to 2.5 mm2

Stranded wire: 0.5 to 1.5 mm2

ExcitationCableforSubmersibleUseandOptionalCodeDHC:

Heat resistant vinyl resin sheath cableOuter diameter ø 10.5 mm

Page 17: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

17<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

nDIMENSIONALDRAWINGSl AXW500toAXW10L,Sizes500mm(20in.)to1000mm(40in.)

*1:This length becomes 21 mm (0.83 in.) shorter when indicator code N is selected.*2:The thickness of optional grounding rings (4mm per one) and customer supplied

gaskets are not included in “L” here.

F13.ai

L (*2)

Ground Terminal

(M4)Eye Bolt

(H2

Hi

)

(H3)

48 (1.89)150 (5.91)

42 (1

.65)

42 (1

.65)

ø 86 (3.38)

H1 H

r

68 (2.68)

56 (2.2)*1

232 (9.13)*1

25 (0.98)48 (1.89)

83 (3.27)

ø128

(5.0

4)

111 (4.37)θ°

(ød)øC

øD

N-øh

Integral TypeFlowmeter

Integral TypeFlowmeter

RemoteFlowtube

RemoteFlowtube

Unit: mm (approx. in.)

(1)ASMEFlangeTypeUnit: mm (approx. in.)

Process Connection Code CA1

Flange Type ASME B16.5 Class150 ASME B16.47 Class150

Size Code 500 600 700 800 900 10L

Size 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)

Lining Code H, F, U, D

Lay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)

Flange Outer Diameter øD 700 (27.56) 815 (32.09) 927 (36.50) 1060 (41.75) 1168 (46.00) 1289 (50.75)

Bolt Circle Diameter øC 635 (25.00) 749.3 (29.50) 863.6 (34.00) 977.9 (38.50) 1086 (42.75) 1200 (47.25)

Inner Diameter ød Lining H, F, D 477 (18.78) 578 (22.76) 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)

Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 9° 9° 6.4° 6.4° 5.6° 5°

Bolt Hole Diameter øh 31.8 (1.25) 34.9 (1.37) 35.1 (1.38) 41.1 (1.62) 41.1 (1.62) 41.1 (1.62)

Number of Bolt Holes N 20 20 28 28 32 36

Height H1 760 (29.92) 875 (34.45) 998 (39.29) 1150 (45.28) 1278 (50.31) 1399 (55.08)

Remote Flowtube, Height H2 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)

Remote Flowtube, Height Hr 812 (31.97) 921 (36.26) 1027 (40.43) 1144 (45.04) 1249 (49.17) 1361 (53.58)

Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 40 (1.57) 50 (1.97) 60 (2.36) 60 (2.36)

Remote Flowtube, Approx. Weight, Unit: kg (lb) 212 (467) 305 (672) 479 (1056) 680 (1499) 882 (1944) 1125 (2480)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692(27.25)

Integral Type, Height Hi 851 (33.50) 960 (37.78) 1065 (41.93) 1183 (46.56) 1288 (50.71) 1400 (55.11)

Integral Type, Approx. Weight, Unit: kg (lb) 215 (474) 308 (679) 482 (1063) 683 (1506) 885 (1951) 1128 (2487)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 18: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

18<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(2)AWWAFlangeTypeUnit: mm (approx. in.)

Process Connection Code CB1Flange Type AWWA C207 Class DSize Code 700 800 900 10LSize 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code H, F, U, DLay Length L 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 927 (36.50) 1060 (41.75) 1168 (46.00) 1289 (50.75)Bolt Circle Diameter øC 863.6 (34.00) 977.9 (38.50) 1086 (42.75) 1200 (47.25)Inner Diameter ød Lining H, F, D 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)

Lining U 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)Bolt Hole Pitch Half Angle θ 6.4° 6.4° 5.6° 5°Bolt Hole Diameter øh 34.9 (1.375) 41.3 (1.625) 41.3 (1.625) 41.3 (1.625)Number of Bolt Holes N 28 28 32 36Remote Flowtube, Height H2 987 (38.86) 1131 (44.53) 1239 (48.78) 1379 (54.29)Remote Flowtube, Height Hr 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 1027 (40.43) 1144 (45.04) 1249 (49.17) 1361 (53.58)Inner Diameter of Eye Bolt 35 (1.38) 40 (1.57) 40 (1.57) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 288 (635) 387 (853) 485 (1069) 659 (1453)

Integral Type, Height H3 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 1065 (41.93) 1183 (46.56) 1288 (50.71) 1400 (55.11)Integral Type, Approx. Weight, Unit: kg (lb) 291 (642) 390 (860) 488 (1076) 662 (1459)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

(3)ENPN10FlangeTypeUnit: mm (approx. in.)

Process Connection Code CE1Flange Type EN1092-1 PN10Size Code 500 600 700 800 900 10LSize 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code H, F, U, DLay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 670 (26.38) 780 (30.71) 895 (35.24) 1015 (39.96) 1115 (43.90) 1230 (48.43)Bolt Circle Diameter øC 620 (24.41) 725 (28.54) 840 (33.07) 950 (37.40) 1050 (41.34) 1160 (45.67)Inner Diameter ød

Lining H, F, D 477 (18.78) 578 (22.76) 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 9° 9° 7.5° 7.5° 6.4° 6.4°Bolt Hole Diameter øh 26 (1.02) 30 (1.18) 30 (1.18) 33 (1.30) 33 (1.30) 36 (1.42)Number of Bolt Holes N 20 20 24 24 28 28Remote Flowtube, Height H2 730 (28.74) 840 (33.07) 955 (37.60) 1086 (42.76) 1186 (46.69) 1320 (51.97)Remote Flowtube, Height Hr 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 797 (31.38) 903 (35.51) 1011 (39.80) 1122 (44.17) 1223 (48.15) 1331 (52.40)Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 35 (1.38) 40 (1.57) 40 (1.57) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 170 (375) 232 (511) 285 (628) 380 (838) 491 (1082) 646 (1424)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 836 (32.91) 942 (37.09) 1049 (41.30) 1160 (45.67) 1262 (49.67) 1370 (53.94)Integral Type, Approx. Weight, Unit: kg (lb) 173 (381) 235 (518) 288 (635) 383 (844) 494 (1089) 649 (1431)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 19: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

19<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(4)ENPN16FlangeType(fluidpressureupto1MPa)Unit: mm (approx. in.)

Process Connection Code CE2Flange Type EN1092-1 PN16Size Code 500 600 700 800 900 10LSize 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code H, F, U, DLay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 715 (28.15) 840 (33.07) 910 (35.83) 1025 (40.35) 1125 (44.29) 1255 (49.41)Bolt Circle Diameter øC 650 (25.59) 770 (30.31) 840 (33.07) 950 (37.40) 1050 (41.34) 1170 (46.06)Inner Diameter ød

Lining H, F, D 477 (18.78) 578 (22.76) 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 9° 9° 7.5° 7.5° 6.4° 6.4°Bolt Hole Diameter øh 33 (1.30) 36 (1.42) 36 (1.42) 39 (1.54) 39 (1.54) 42 (1.65)Number of Bolt Holes N 20 20 24 24 28 28Remote Flowtube, Height H2 775 (30.51) 900 (35.43) 970 (38.19) 1096 (43.15) 1196 (47.09) 1345 (52.95)Remote Flowtube, Height Hr 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 820 (32.28) 933 (36.73) 1018 (40.08) 1127 (44.37) 1228 (48.37) 1344 (52.91)Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 35 (1.38) 40 (1.57) 40 (1.57) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 230 (507) 350 (772) 330 (728) 427 (941) 535 (1179) 742 (1636)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 859 (33.80) 972 (38.28) 1056 (41.59) 1165 (45.87) 1267 (49.87) 1383 (54.44)Integral Type, Approx. Weight, Unit: kg (lb) 233 (514) 353 (778) 333 (734) 430 (948) 538 (1186) 745 (1642)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

(5)JIS10KFlangeTypeUnit: mm (approx. in.)

Process Connection Code CJ1Flange Type JIS B2220 10KSize Code 500 600 700 800 900 10LSize 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code H, F, U, DLay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 675 (26.57) 795 (31.30) 905 (35.63) 1020 (40.16) 1120 (44.09) 1235 (48.62)Bolt Circle Diameter øC 620 (24.41) 730 (28.74) 840 (33.07) 950 (37.40) 1050 (41.34) 1160 (45.67)Inner Diameter ød

Lining H, F, D 477 (18.78) 578 (22.76) 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 9° 7.5° 7.5° 6.4° 6.4° 6.4°Bolt Hole Diameter øh 27 (1.06) 33 (1.30) 33 (1.30) 33 (1.30) 33 (1.30) 39 (1.54)Number of Bolt Holes N 20 24 24 28 28 28Remote Flowtube, Height H2 735 (28.94) 855 (33.66) 965 (37.99) 1091 (42.95) 1191 (46.89) 1325 (52.17)Remote Flowtube, Height Hr 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 800 (31.50) 911 (35.87) 1016 (40.00) 1124 (44.25) 1225 (48.23) 1334 (52.2)Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 35 (1.38) 40 (1.57) 40 (1.57) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 156 (344) 223 (492) 310 (683) 408 (899) 522 (1151) 689 (1519)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 839 (33.01) 950 (37.39) 1054 (41.49) 1163 (45.77) 1264 (49.77) 1373 (54.04)Integral Type, Approx. Weight, Unit: kg (lb) 159 (351) 226 (498) 313 (690) 411 (906) 525 (1157) 692 (1526)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 20: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

20<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(6)AS2129TableDFlangeTypeUnit: mm (approx. in.)

Process Connection Code CS1Flange Type AS2129 Table DSize Code 500 600 700 800 900 10LSize 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code H, F, U, DLay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 705 (27.76) 825 (32.48) 910 (35.83) 1060 (41.73) 1175 (46.26) 1255 (49.41)Bolt Circle Diameter øC 641 (25.24) 756 (29.76) 845 (33.27) 984 (38.74) 1092 (42.99) 1175 (46.26)Inner Diameter ød

Lining H, F, D 477 (18.78) 578 (22.76) 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 11.3° 11.3° 9° 9° 7.5° 7.5°Bolt Hole Diameter øh 26 (1.02) 30 (1.18) 30 (1.18) 36 (1.42) 36 (1.42) 36 (1.42)Number of Bolt Holes N 16 16 20 20 24 24Remote Flowtube, Height H2 765 (30.12) 885 (34.84) 970 (38.19) 1131 (44.53) 1265 (49.80) 1345 (52.95)Remote Flowtube, Height Hr 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 815 (32.09) 926 (36.46) 1018 (40.08) 1144 (45.04) 1253 (49.33) 1344 (52.91)Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 35 (1.38) 40 (1.57) 50 (1.97) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 157 (346) 225 (496) 290 (639) 433 (977) 594 (1310) 728 (1605)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 854 (33.60) 965 (37.98) 1056 (41.59) 1183 (46.56) 1292 (50.85) 1383 (54.44)Integral Type, Approx. Weight, Unit: kg (lb) 160 (353) 228 (503) 293 (646) 436 (961) 597 (1316) 731 (1612)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

(7)AS2129TableEFlangeTypeUnit: mm (approx. in.)

Process Connection Code CS2Flange Type AS2129 Table ESize Code 500 600 700 800 900 10LSize 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code H, F, U, DLay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 705 (27.76) 825 (32.48) 910 (35.83) 1060 (41.73) 1175 (46.26) 1255 (49.41)Bolt Circle Diameter øC 641 (25.24) 756 (29.76) 845 (33.27) 984 (38.74) 1092 (42.99) 1175 (45.67)Inner Diameter ød

Lining H, F, D 477 (18.78) 578 (22.76) 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 11.3° 11.3° 9° 9° 7.5° 7.5°Bolt Hole Diameter øh 26 (1.02) 33 (1.30) 33 (1.30) 36 (1.42) 36 (1.42) 39 (1.54)Number of Bolt Holes N 16 16 20 20 24 24Remote Flowtube, Height H2 765 (30.12) 885 (34.84) 970 (38.19) 1131 (44.53) 1265 (49.80) 1345 (52.95)Remote Flowtube, Height Hr 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 815 (32.09) 926 (36.46) 1018 (40.08) 1144 (45.04) 1253 (49.33) 1344 (52.91)Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 35 (1.38) 40 (1.57) 50 (1.97) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 184 (406) 288 (635) 354 (780) 508 (1120) 703 (1550) 832 (1834)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 854 (33.60) 965 (37.98) 1056 (41.59) 1183 (46.56) 1292 (50.85) 1383 (54.44)Integral Type, Approx. Weight, Unit: kg (lb) 187 (412) 291 (642) 357 (787) 511 (1127) 706 (1556) 835 (1841)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 21: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

21<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(8)AS4087PN16FlangeTypeUnit: mm (approx. in.)

Process Connection Code CT1Flange Type AS4087 PN16Size Code 500 600 700 800 900 10LSize 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code H, F, U, DLay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 705 (27.76) 825 (32.48) 910 (35.83) 1060 (41.73) 1175 (46.26) 1255 (49.41)Bolt Circle Diameter øC 641 (25.24) 756 (29.76) 845 (33.27) 984 (38.74) 1092 (42.99) 1175 (45.67)Inner Diameter ød

Lining H, F, D 477 (18.78) 578 (22.76) 675 (26.57) 777 (30.59) 878 (34.57) 976 (38.43)Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 11.3° 11.3° 9° 9° 7.5° 7.5°Bolt Hole Diameter øh 26 (1.02) 30 (1.18) 30 (1.18) 36 (1.42) 36 (1.42) 36 (1.42)Number of Bolt Holes N 16 16 20 20 24 24Remote Flowtube, Height H2 765 (30.12) 885 (34.84) 970 (38.19) 1131 (44.53) 1265 (49.80) 1345 (52.95)Remote Flowtube, Height Hr 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 815 (32.09) 926 (36.46) 1018 (40.08) 1144 (45.04) 1253 (49.33) 1344 (52.91)Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 35 (1.38) 40 (1.57) 50 (1.97) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 184 (406) 288 (635) 374 (825) 520 (1146) 716 (1579) 826 (1821)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 854 (33.60) 965 (37.98) 1056 (41.59) 1183 (46.56) 1292 (50.85) 1383 (54.44)Integral Type, Approx. Weight, Unit: kg (lb) 187 (412) 291 (642) 377 (831) 523 (1153) 719 (1585) 829 (1828)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

(9)JISF12(JIS75M)FlangeTypeUnit: mm (approx. in.)

Process Connection Code CG1Flange Type JIS G3443-2 F12Size Code 500 600 700 800 900 10LSize 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)Lining Code ULay Length L 600 (23.62) 720 (28.35) 840 (33.07) 960 (37.80) 1080 (42.52) 1200 (47.24)Flange Outer Diameter øD 706 (27.80) 810 (31.89) 928 (36.54) 1034 (40.71) 1156 (45.51) 1262 (49.69)Bolt Circle Diameter øC 639 (25.16) 743 (29.25) 854 (33.62) 960 (37.80) 1073 (42.24) 1179 (46.42)Inner Diameter ød Lining U 469 (18.46) 570 (22.44) 667 (26.26) 769 (30.28) 870 (34.25) 968 (38.11)

Bolt Hole Pitch Half Angle θ 15° 11.3° 11.3° 9° 9° 7.5°Bolt Hole Diameter øh 27 (1.06) 27 (1.06) 33 (1.30) 33 (1.30) 33 (1.30) 33 (1.30)Number of Bolt Holes N 12 16 16 20 20 24Remote Flowtube, Height H2 766 (30.16) 870 (34.25) 988 (38.90) 1105 (43.50) 1227 (48.31) 1352 (53.23)Remote Flowtube, Height Hr 408 (16.06) 459 (18.07) 509 (20.04) 560 (22.05) 611 (24.06) 662 (26.06)Height Hr 816 (32.13) 919 (36.18) 1028 (40.47) 1132 (44.57) 1245 (49.02) 1349 (53.11)Inner Diameter of Eye Bolt 35 (1.38) 35 (1.38) 35 (1.38) 40 (1.57) 40 (1.57) 50 (1.97)Remote Flowtube, Approx. Weight, Unit: kg (lb) 168 (370) 228 (503) 319 (703) 404 (891) 540 (1190) 703 (1550)

Integral Type, Height H3 438 (17.24) 489 (19.26) 538 (21.20) 590 (23.21) 641 (25.24) 692 (27.25)Integral Type, Height Hi 854 (33.62) 957 (37.69) 1065 (41.94) 1170 (46.04) 1282 (50.48) 1386 (54.57)Integral Type, Approx. Weight, Unit: kg (lb) 171 (377) 231 (509) 322 (710) 407 (897) 543 (1197) 706 (1556)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 22: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

22<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

l OptionalGroundingRings(GR1)forsizes500mm(20in.)to1000mm(40in.)

(ød)

øD

ø25 (0.98)

L1 L2

L1

L2

F14.ai

Unit: mm (approx. in.)Process Connection Code CA1, CB1, CE1, CE2, CJ1, CS1, CS2, CT1, CG1

Size Code 500 600 700 800 900 10L

Size 500 (20) 600 (24) 700 (28) 800 (32) 900 (36) 1000 (40)

Lining Code H, F, U, D

Ring Outer Diameter øD 590 (23.23) 690 (27.17) 799 (31.46) 906 (35.67) 1006 (39.61) 1116 (43.94)

Ring Inner Diameter ød 485 (19.09) 586 (23.07) 683 (26.89) 787 (30.98) 888 (34.96) 986 (38.82)

Length L1 410 (16.14) 477.5 (18.80) 517.5 (20.37) 586 (23.07) 640 (25.20) 697.5 (27.46)

Length L2 390 (15.35) 457.5 (18.01) 497.5 (19.59) 566 (22.28) 620 (24.41) 677.5 (26.67)

Thickness 4 (0.16)

Approx. Weight, Unit: kg (lb) 3.1 (6.8) 3.7 (8.1) 4.6 (10.2) 5.4 (12.0) 6.0 (13.3) 7.3 (16.1)

Apr. 27, 2017-00

Page 23: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

23<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

l AXW11LtoAXW18L, Sizes1100mm(44in.)to1800mm(72in.)

ø86 (3.38)Ground Terminal (M4)

4-M8(for Grounding Ring)(Except for JIS F12 flange models)

Eye Plate 48 (1.89)

111 (4.37)

N-øh

L (*)T

F15.ai

(ød)øD

øC1 (øh)

øC2 (M8)

(H2)

Hr

θ°

*: The thickness of optional grounding rings (5 mm for GR1 and

25 mm for GR2 per one) and customer supplied gaskets are

not included in “L” here.

Remote Flowtube

(1)AWWAFlangeTypeUnit: mm (approx. in.)

Process Connection Code CB1

Flange Type AWWA C207 Class D

Size Code 12L

Size 1200 (48)

Lining Code H

Lay Length L 1440 (56.69)

Flange Outer Diameter øD 1511.3 (59.50)

Flange Bolt Circle Diameter øC1 1422.4 (56.00)

Ring Bolt Circle Diameter øC2 1426 (56.14)

Inner Diameter ød Lining H 1189 (46.81)

Bolt Hole Pitch Half Angle θ 4.1°

Bolt Hole Diameter øh 41.3 (1.625)

Number of Bolt Holes N 44

Height H2 770 (30.31)

Height Hr 1580 (62.20)

Inner Diameter of Eye Plate 60 (2.36)

Approx. Weight, Unit: kg (lb) 930 (2050)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 24: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

24<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(2)ENPN6FlangeType Unit: mm (approx. in.)

Process Connection Code CEJ

Flange Type EN1092-1 PN6

Size Code 12L 14L 16L 18L

Size 1200 (48) 1400 (56) 1600 (64) 1800 (72)

Lining Code H

Lay Length L 1440 (56.69) 1680 (66.14) 1920 (75.59) 2160 (85.04)

Flange Outer Diameter øD 1405 (55.31) 1630 (64.17) 1830 (72.05) 2045 (80.51)

Flange Bolt Circle Diameter øC1 1340 (52.76) 1560 (61.42) 1760 (69.29) 1970 (77.56)

Ring Bolt Circle Diameter øC2 1356 (53.39) 1572 (61.89) 1772 (69.76) 1981 (77.99)

Inner Diameter ød Lining H 1195 (47.05) 1398 (55.04) 1586 (62.44) 1784 (70.24)

Bolt Hole Pitch Half Angle θ 5.6° 5° 4.5° 4.1°

Bolt Hole Diameter øh 33 (1.30) 36 (1.42) 36 (1.42) 39 (1.54)

Number of Bolt Holes N 32 36 40 44

Height H2 770 (30.31) 873 (34.37) 969 (38.15) 1068 (42.05)

Height Hr 1527 (60.12) 1742 (69.49) 1938 (76.30) 2145 (84.45)

Inner Diameter of Eye Plate 60 (2.36) 70 (2.76) 70 (2.76) 80 (3.15)

Approx. Weight, Unit: kg (lb) 620 (1367) 920 (2028) 1310 (2888) 1670 (3682)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

(3)ENPN10FlangeType(fluidpressureupto0.6MPa)Unit: mm (approx. in.)

Process Connection Code CEK

Flange Type EN1092-1 PN10

Size Code 12L 14L 16L 18L

Size 1200 (48) 1400 (56) 1600 (64) 1800 (72)

Lining Code H

Lay Length L 1440 (56.69) 1680 (66.14) 1920 (75.59) 2160 (85.04)

Flange Outer Diameter øD 1455 (57.28) 1675 (65.94) 1915 (75.39) 2115 (83.27)

Flange Bolt Circle Diameter øC1 1380 (54.33) 1590 (62.60) 1820 (71.65) 2020 (79.53)

Ring Bolt Circle Diameter øC2 1391 (54.76) 1596 (62.83) 1822 (71.73) 2022 (79.61)

Inner Diameter ød Lining H 1195 (47.05) 1398 (55.04) 1586 (62.44) 1784 (70.24)

Bolt Hole Pitch Half Angle θ 5.6° 5° 4.5° 4.1°

Bolt Hole Diameter øh 39 (1.54) 42 (1.65) 48 (1.89) 48 (1.89)

Number of Bolt Holes N 32 36 40 44

Height H2 770 (30.31) 873 (34.37) 969 (38.15) 1068 (42.05)

Height Hr 1552 (61.10) 1765 (69.49) 1981 (77.99) 2180 (85.83)

Inner Diameter of Eye Plate 60 (2.36) 70 (2.76) 70 (2.76) 80 (3.15)

Approx. Weight, Unit: kg (lb) 790 (1742) 1120 (2469) 1720 (3792) 2130 (4696)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 25: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

25<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(4)ENPN10FlangeTypeUnit: mm (approx. in.)

Process Connection Code CE1

Flange Type EN1092-1 PN10

Size Code 12L 14L 16L 18L

Size 1200 (48) 1400 (56) 1600 (64) 1800 (72)

Lining Code H

Lay Length L 1440 (56.69) 1680 (66.14) 1920 (75.59) 2160 (85.04)

Flange Outer Diameter øD 1455 (57.28) 1675 (65.94) 1915 (75.39) 2115 (83.27)

Flange Bolt Circle Diameter øC1 1380 (54.33) 1590 (62.60) 1820 (71.65) 2020 (79.53)

Ring Bolt Circle Diameter øC2 1391 (54.76) 1596 (62.83) 1822 (71.73) 2022 (79.61)

Inner Diameter ød Lining H 1189 (16.81) 1390 (54.72) 1582 (62.28) 1776 (69.92)

Bolt Hole Pitch Half Angle θ 5.6° 5° 4.5° 4.1°

Bolt Hole Diameter øh 39 (1.54) 42 (1.65) 48 (1.89) 48 (1.89)

Number of Bolt Holes N 32 36 40 44

Height H2 770 (30.31) 873 (34.37) 969 (38.15) 1068 (42.05)

Height Hr 1552 (61.10) 1765 (69.49) 1981 (77.99) 2180 (85.83)

Inner Diameter of Eye Plate 60 (2.36) 70 (2.76) 70 (2.76) 80 (3.15)

Approx. Weight, Unit: kg (lb) 920 (2028) 1340 (2954) 1860 (4101) 2510 (5534)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

(5)AS2129TableD,AS2129TableE,AS4087PN16FlangeTypeUnit: mm (approx. in.)

Process Connection Code CS1 CS2 CT1

Flange Type AS2129 Table D AS2129 Table E AS4087 PN16

Size Code 12L

Size 1200 (48)

Lining Code H

Lay Length L 1440 (56.69) 1440 (56.69) 1440 (56.69)

Flange Outer Diameter øD 1490 (58.66) 1490 (58.66) 1490 (58.66)

Flange Bolt Circle Diameter øC1 1410 (55.51) 1410 (55.51) 1410 (55.51)

Ring Bolt Circle Diameter øC2 1426 (56.14) 1426 (56.14) 1426 (56.14)

Inner Diameter ød Lining H 1189 (46.81) 1189 (46.81) 1189 (46.81)

Bolt Hole Pitch Half Angle θ 5.6° 5.6° 5.6°

Bolt Hole Diameter øh 36 (1.42) 39 (1.54) 36 (1.42)

Number of Bolt Holes N 32 32 32

Height H2 770 (30.31) 770 (30.31) 770 (30.31)

Height Hr 1570 (61.81) 1570 (61.81) 1570 (61.81)

Inner Diameter of Eye Plate 60 (2.36) 60 (2.36) 60 (2.36)

Approx. Weight, Unit: kg (lb) 1050 (2315) 1210 (2668) 1180 (2601)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 26: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

26<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(6)JISF12(JIS75M)FlangeTypeUnit: mm (approx. in.)

Process Connection Code CG1

Flange Type JIS G3443-2 F12

Size Code 11L 12L 13L 15L 16L 18L

Size 1100 (44) 1200 (48) 1350 (54) 1500 (60) 1600 (64) 1800 (72)

Lining Code U

Lay Length L 1320 (51.97) 1440 (56.69) 1620 (63.78) 1800 (70.87) 1920 (75.59) 2160 (85.04)

Flange Outer Diameter øD 1366 (53.78) 1470 (57.87) 1642 (64.65) 1800 (70.87) 1915 (75.39) 2115 (83.27)

Bolt Circle Diameter øC 1283 (50.51) 1387 (54.61) 1552 (61.10) 1710 (67.32) 1820 (71.65) 2020 (79.53)

Grounding Ring Inner Diameter ød

Lining U 1071 (42.17) 1172 (46.14) 1322 (52.05) 1469 (57.83) 1565 (61.61) 1759 (69.25)

Bolt Hole Pitch Half Angle θ 7.5° 6.4° 6.4° 5.6° 5° 4.1°

Bolt Hole Diameter øh 33 (1.30) 33 (1.30) 39 (1.54) 39 (1.54) 39 (1.54) 39 (1.54)

Number of Bolt Holes N 24 28 28 32 36 44

Height H2 720 (28.35) 770 (30.31) 847 (33.35) 921 (36.26) 969 (38.15) 1068 (42.05)

Height Hr 1457 (57.36) 1560 (61.42) 1723 (67.83) 1875 (73.82) 1981 (77.99) 2180 (85.83)

Inner Diameter of Eye Plate 60 (2.36) 60 (2.36) 70 (2.76) 70 (2.76) 70 (2.76) 80 (3.15)

Approx. Weight, Unit: kg (lb) 910 (2006) 1060 (2337) 1430 (3153) 1770 (3902) 2090 (4608) 2890 (6371)

Note: When submersible type or option code DHC is selected, waterproof glands and a 30-meter length cable as standard are attached. Add 9.5 kg (20.9 lb) to the weight in the table.

Apr. 27, 2017-00

Page 27: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

27<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

l OptionalGroundingRings(GR1)forsizes1200mm(48in.)to1800mm(72in.)

(ød)

øCøD

ø11 (0.43)

F16.ai

ø35 (1.38)

L1

L1 L1

L2

Unit: mm (approx. in.)

Process Connection Code CB1, CS1, CS2,CT1 CEJ CEK, CE1

Flange TypeAWWA C207-D

AS2129-D,E AS4087 PN16

EN1092-1 PN6 EN1092-1 PN10

Size Code 12L 12L 14L 16L 18L 12L 14L 16L 18L

Size 1200(48)

1200(48)

1400(56)

1600(64)

1800(72)

1200(48)

1400(56)

1600(64)

1800(72)

Lining Code H

Ring Outer Diameter øD 1370 (53.94)

1300 (51.18)

1516(59.69)

1716(67.56)

1925(75.79)

1335(52.56)

1540(60.63)

1766(69.53)

1966(77.40)

Ring Inner Diameter ød 1195 (47.05)

1201(47.28)

1404(55.28)

1592(62.68)

1790(70.47)

1195(47.05)

1396(54.96)

1588(62.52)

1782(70.16)

Bolt Circle Diameter øC 1426 (56.14)

1356(53.39)

1572(61.89)

1772(69.76)

1981(77.99)

1391(54.76)

1596(62.83)

1822(71.73)

2022(79.61)

Length L1 735 (28.94)

700(27.56)

808(31.81)

908(35.75)

1012.5(39.86)

717.5(28.25)

820(32.28)

933(36.73)

1033(40.67)

Length L2 815 (32.09)

780(30.71)

888(34.96)

988(38.90)

1092.5(43.01)

797.5(31.40)

900(35.43)

1013(39.88)

1113(43.82)

Thickness 5 (0.20)

Approx. Weight, Unit: kg (lb)

14.6(32.2)

8.2(18.1)

10.7(23.6)

13.3(29.3)

16.2(35.7)

11.6(25.6)

13.7(30.2)

19.2(42.3)

22.1 (48.7)

l OptionalGroundingRings(GR2)forsizes1100mm(44in.)to1800mm(72in.)

Unit: mm (approx. in.)

Process Connection Code CG1

Flange Type JIS G3443-2 F12

Size Code 11L 12L 13L 15L 16L 18L

Size 1100(44)

1200(48)

1350(54)

1500(60)

1600(64)

1800(72)

Lining Code U

Thickness 25 (0.98)

Approx. Weight, Unit: kg (lb)

59.3(131)

65.7(145)

75.8(167)

88.3(195)

92.4(204)

114.2(252)

*: Optional grounding rings (GR2) have no protruding brackets and are installed and locked onto the flowtube with gaskets B when shipped from factory. Refer to “CAUTIONS ON SELECTION AND INSTALLATION”.

Apr. 27, 2017-00

Page 28: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

28<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

Note: Unless otherwise specified, refer to the following table for tolerance in the dimensions.

Generaltoleranceinthedimensionaloutlinedrawing.Unit: mm (approx. in.)

Category of basic dimensionTolerance

Category of basic dimensionTolerance

Above Equal or below Above Equal or below

3 (0.12)6 (0.24)

10 (0.39)18 (0.71)30 (1.18)50 (1.97)80 (3.15)

120 (4.72)180 (7.09)250 (9.84)

315 (12.40)400 (15.75)

3 (0.12)6 (0.24)

10 (0.39)18 (0.71)30 (1.18)50 (1.97)80 (3.15)

120 (4.72)180 (7.09)250 (9.84)

315 (12.40)400 (15.75)500 (19.69)

±0.7 (±0.03)±0.9 (±0.04)±1.1 (±0.04)

±1.35 (±0.05)±1.65 (±0.06)±1.95 (±0.08)±2.3 (±0.09)±2.7 (±0.11)

±3.15 (±0.12)±3.6 (±0.14)

±4.05 (±0.16)±4.45 (±0.18)±4.85 (±0.19)

500 (19.69)630 (24.80)800 (31.50)

1000 (39.37)1250 (49.21)1600 (62.99)2000 (78.74)2500 (98.43)

630 (24.80)800 (31.50)

1000 (39.37)1250 (49.21)1600 (62.99)2000 (78.74)2500 (98.43)

3150 (124.02)

±5.5 (±0.22)±6.25 (±0.25)±7.0 (±0.28)

±8.25 (±0.32)±9.75 (±0.38)±11.5 (±0.45)±14.0 (±0.55)±16.5 (±0.65)

Remarks: The numeric is based on criteria of tolerance class IT18 in JIS B 0401-1.

nSIZINGDATANote: Measurable flow velocity is from 0 m/s.

10.0

1.0

0.1

0.3

10 100 1,000 10,000 100,000Flowrate (m3/h)

SI Units Size: mm

Flow

vel

ocity

(m/s

)

500 600 700 800 90010001100

12001350

14001500

16001800

F17.ai

Flowrate (GPM)

Flow

vel

ocity

(ft/s

)

English UnitsSize: inch

20 24 28 32 36 40 44 48 54 56 64 72

0.33

1

10

33

10 100 1,000 10,000 100,000 1,000,000

F18.ai

Apr. 27, 2017-00

Page 29: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

29<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

nORDERINGINFORMATIONNote1:Whenordering,thespanflowrate,unit,out-

putpulseweight,andtotalizerdisplaypulseweightcanbespecified.Theseparameterswillthenbesetbeforeshipment.Inthecaseofremotetype,specifycombi-nationinformationofsensor(orflowtube)andtransmitter(orconverter).Theseparameterswillbesetinthecom-binedtransmitter.Whenorderingofaremotesensoraloneoraremotetransmitteralone,theseparam-eterscannotbespecified.Customconfigurationrequestisnecessaryforsettingtheseparametersoutofregularsettingrange.

Note2:Someoptions,ifordered,requiretherelevantspecificationstobeinputwhenordering.

Note3:WhenorderingAXW4AorAXFA11asacombinedremotetransmitter,pleasealsorefertotheorderinginformationineachGeneralSpecificationslistedonthefrontpageastherearesomedifferencesinor-deringprocedureandspecification.

1. Model, Specification and Optional Code2. Combination (Remote Type)

This is necessary when ordering remote type flowmeters with certain combination of sensors and transmitters. Specify the combination of a sen-sor and a transmitter one by one by their model name, specification code, or Tag No. etc. On the nameplate of each sensor and transmitter, the se-rial number of the specified combination partner is described.

3. Tag No.The tag No. can be specified by a combination of uppercase letters, lowercase letters (for HART communication excludes lower case letters), numbers, “- (hyphen)”, “. (period)”, and “ (space). Please refer to the table below for specifying pro-cedure.

ItemstobeSpecified

Described/SettingDestination

MaximumNumberofCharacters

TAG NO

• Nameplate• Stainless steel tag plate

(with optional code SCT)16

• Memory in transmitter amplifierSee belowSOFTWARE

TAG• Memory in transmitter amplifier

(Overrides TAG NO designation)

In the case of integral type and remote transmit-ter, the characters specified by “TAG NO” are also written to the memory (parameter) in the transmit-ter amplifier. If it is necessary to specify a different tag number only for the transmitter memory, please specify “SOFTWARE TAG”. It is also possible to specify only SOFTWARE TAG. Names of the pa-rameter to be written and the maximum number of characters are as shown in the table below. If the number of specified characters exceed the maxi-mum number, the characters from the beginning up to the maximum number is written.

Apr. 27, 2017-00

ItemstobeSpecified

TransmitterMemory MaximumNumberofCharactersCommunica-

tionParameterName

TAG NO and SOFTWARE

TAG

BRAIN TAG NO 16

HART 7Long Tag (*) 16

Tag 8

* For AXFA11G HART Communication type, “Long Tag” is not available as its protocol version is HART 5.

4. Span Flow Rate and UnitSpecify the range of span flow rate in the range of 0.0001 to 999999000000.0000 (the number of significant digits in operation is the upper 6 digits). Up to four digits below the decimal point that can be specified (by 0.001 unit). However, if the transmitter is BRAIN communication type, specify so that it is within the range of 0.0001 to 32000, it is up to four digits below the decimal point when it is included, and the numerical value excluding the decimal point is within 32000.Specify units in the unit described in “Span Set-ting”. This span flow rate is set to the positive first range. Be sure to specify the span flow rate and unit when selecting the Mass Unit Setting (optional code MU), or Specified Span 5-point Calibration (optional code SC). If not specified, it is set in vol-ume unit (m3/h) equivalent to 1 m/s flow rate when shipped, except for AXFA11 transmitter where it is set as 1 m/s in velocity unit.The measurement flow range (minimum and maxi-mum of span flow rate) is shown below (in the case of flow rate unit m3/h and GPM). Specify the span flow within this range. The range specifying differ-ent unit must also fall into the same flow rate (flow velocity) range after conversion.

MeasurableFlowRateRange(1) Integral Type or Remote Sensor with AXW4A

TransmitterSI Units (Size: mm., Flow rate: m3/h)

Size(mm)

0toMin.SpanFlowRate 0toMax.SpanFlowRatem3/h(0.1m/s) m3/h(10m/s)

500 0 to 70.6859 0 to 7068.58600 0 to 101.788 0 to 10178.7700 0 to 138.545 0 to 13854.4800 0 to 180.956 0 to 18095.5900 0 to 229.023 0 to 22902.21000 0 to 282.744 0 to 28274.3

English Units (Size: in., Flow rate: GPM)Size(in.)

0toMin.SpanFlowRate 0toMax.SpanFlowRateGPM(0.33ft/s) GPM(33ft/s)

20 0 to 311.221 0 to 3112224 0 to 448.158 0 to 44815.728 0 to 609.992 0 to 60999.132 0 to 796.725 0 to 79672.436 0 to 1008.36 0 to 10083540 0 to 1244.89 0 to 124488

Page 30: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

30<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01EN

(2) Remote Sensor with AXFA11 TransmitterSize

mm(in.)Min.Span

0.1m/s(0.33ft/s)Max.Span

10m/s(33ft/s)

500 (20) 0 to 70.69 m3/h(0 to 311.3 GPM)

0 to 7,068 m3/h(0 to 31,122 GPM)

600 (24) 0 to 101.79(0 to 448.2)

0 to 10,178(0 to 44,815)

700 (28) 0 to 138.55(0 to 610.0)

0 to 13,854(0 to 60,999)

800 (32) 0 to 180.96(0 to 796.8)

0 to 18,095(0 to 79,672)

900 (36) 0 to 229.03(0 to 1,009)

0 to 22,902(0 to 100,835)

1000 (40) 0 to 282.75(0 to 1,245)

0 to 28,274(0 to 124,488)

Sizemm(in.)

Min.Span0.3m/s(1ft/s)

Max.Span10m/s(33ft/s)

1100 (44) 0 to 1,026.4 m3/h(0 to 4,519 GPM)

0 to 34,211 m3/h(0 to 150,630 GPM)

1200 (48) 0 to 1,221.5(0 to 5,378)

0 to 40,715(0 to 179,262)

1350 (54) 0 to 1,545.9(0 to 6,807)

0 to 51,529(0 to 226,879)

1400 (56) 0 to 1,662.5(0 to 7,320)

0 to 55,418(0 to 243,997)

1500 (60) 0 to 1,908.6(0 to 8,403)

0 to 63,617(0 to 280,098)

1600 (64) 0 to 2,171.5(0 to 9,561)

0 to 72,382(0 to 318,689)

1800 (72) 0 to 2,748.3(0 to 12,101)

0 to 91,608(0 to 403,341)

5. Output Pulse Weight (Pulse Status Output 1) Specify the volume flow per pulse, after specifying the span flow rate. This output pulse weight is set to the Pulse Status Output 1. Specify it in the same unit as the span flow rate.(Example: When “m3” is selected as “Span Flow Rate”, specify “10 m3/p” as pulse weight unit.)The specifiable numerical digit and range is the same as that for “4. Span Flow Rate and Unit”.Unless specified, it is set as 0 [span unit/p] when shipped.

6. Totalizer Display Pulse Weight (Totalizer 1)Specify the volume flow per pulse, after specify-ing the span flow rate. This totalizer display pulse weight is set to the Totalizer 1. Specify it in the same unit as the span flow rate.(Example: When “m3” is selected as “Span Flow Rate”, specify “10 m3/p” as totalizer display pulse weight unit.)The specifiable numerical digit and range is the same as that for “4. Span Flow Rate and Unit”.Unless specified, it is set as 1 [span unit/p] when shipped, except for AXFA11 transmitter where it is set as 0. Additionally, if there were no setting for the span flow rate, it is always set as 0 [span unit/p] when shipped.

7. Mass Unit (optional code MU)This option performs flow rate calculation in mass unit. In addition to fluid density, specify span flow rate, output pulse weight, and totalizer display pulse weight in mass unit.The specifiable numerical digit and range is the same as that for “4. Span Flow Rate and Unit”.(1) Density

Numerical Range: Specify within 6 digits (up to 4 digits below the decimal point) in the range of 500 to 2000 kg/m3 (4.2 to 16.7 lb/gal *, 31.2 to 124.8 lb/cf). If the transmitter is BRAIN communica-tion type, specify so that the numerical value excluding the decimal point is within 32000.

Unit:kg/m3, lb/gal, lb/cf The density of water is about 1000 kg/m3. Then specify “1000 kg/m3” in this case. However, as the density varies with tempera-ture, specify the density at the time of flow measurement.

(2) Span Flow Rate Numerical Range:

When setting the mass span flow rate, calculate the volume span flow rate from the “density” and it must be within the measur-able flow rate range. The settable numerical range for the mass span flow rate is the same as that for the volume span flow rate.

Unit:Mass Unit: t, kg, g, klb, lbTime Unit: /d, /h, /min, /s

(3) Output Pulse Weight, Totalizer Display Pulse Weight

Set the value with the same unit as that for the mass span flow rate.

8. Specified Span Five-point Calibration (optional code SC)A flow test at the five points around 0, 25, 50, 75, 100% of the customer specified span is performed. In the test certificate (QIC), the result for the cus-tomer specified span is recorded instead of that for the standard flow rate of 2 m/s. Corresponding flow velocity of the selectable span lies between 0.5 to 10 m/s (1.64 to 33 ft/s) or 0.8 to 10 m/s (2.62 to 33 ft/s). The latter is applied when the size is 32, 65, or 125 mm (1.25, 2.5, or 5 in.). It is also limited by the capacity of our flow test facility. Specify it within the following range. The specifiable numerical digit and range is the same as that for “4. Span Flow Rate and Unit”.

SelectableRangeofSpanFlowRate(m3/h)Sizemm

Min.SpanFlowRate Max.SpanFlowRatem3/h (m/s) m3/h (m/s)

500 354 (0.5) 7068 (10.00)600 509 (0.5) 8200 (8.06)700 693 (0.5) 8200 (5.92)800 905 (0.5) 8200 (4.53)900 1146 (0.5) 8200 (3.58)1000 1414 (0.5) 8200 (2.90)1100 1711 (0.5) 8200 (2.40)1200 2036 (0.5) 8200 (2.01)1350 2577 (0.5) 30000 (5.82)1400 2771 (0.5) 30000 (5.41)1500 3181 (0.5) 30000 (4.71)1600 3620 (0.5) 30000 (4.14)1800 4581 (0.5) 30000 (3.27)

Apr. 27, 2017-00

Page 31: General Specifi cations - Yokogawa Electric · * : The setting is English when shipped from factory. Display Screen Configuration: Display Screen Item: Status display (icon), Time

31<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation GS 01E25D11-01ENSubject to change without notice.

SelectableRangeofSpanFlowRate(GPM)Size(in.)

Min.SpanFlowRate Max.SpanFlowRateGPM (ft/s) GPM (ft/s)

20 1556.11 (1.64) 31119.4 (32.81)24 2240.79 (1.64) 36103.5 (26.44)28 3049.96 (1.64) 36103.5 (19.42)32 3983.63 (1.64) 36103.5 (14.86)36 5041.77 (1.64) 36103.5 (11.75)40 6224.41 (1.64) 36103.5 (9.51)44 7531.54 (1.64) 36103.5 (7.87)48 8963.15 (1.64) 36103.5 (6.59)54 11344 (1.64) 132086 (19.09)56 12199.9 (1.64) 132086 (17.75)60 14005 (1.64) 132086 (15.45)64 15934.5 (1.64) 132086 (13.58)72 20167.1 (1.64) 132086 (10.73)

9. Direction of Electrical Connection (Cable Entry) (optional code RA, RB, RC)This option rotates the transmitter part of the integral type flowmeter or the terminal box of the remote sensor and change the direction of the electrical connection. Refer to the table below and select an optional code for + 90 °(RA), + 180 °(RB) or -90 °(RC). For the standard direction (0 °), this optional code is not necessary.

DirectionofElectricalConnection(CableEntry)

Standard(0°)

+90°rotation

+180°rotation

-90°rotation

OptionalCodeRA

OptionalCodeRB

OptionalCodeRC

Integral Type

Electrical Connection Display Electrical

Connection Display

Remote Flowtube

Front side Electrical Connection Back side Electrical

Connection

10. Direction of Indicator (Display)When the specification “With Indicator” is selected for the integral type flowmeter, specify direction of the indicator according to the horizontal or vertical direction of the installation piping.

DirectionofIndicator WithoutIndicatorHorizontal Vertical

Integral Type

11. Fluid Name

nRELATEDINSTRUMENTSProduct DocumentNumber

AM012 Calibrator for Magnetic Flowmeter GS 1E6K2-EBT200 BRAIN TERMINAL GS 01C00A11-00ENAXFA11G Magnetic Flowmeter Remote Converter GS 01E20C01-01E

ADMAG CA Capacitance Magnetic Flowmeter GS 01E08B01-00EFieldMate Versatile Device Management Wizard GS 01R01A01-01EADMAG TI Series AXG Magnetic Flowmeter GS 01E22A01-01EN

ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm] GS 01E24A01-01EN

nREFERENCESTANDARDDesign and Test on Magnetic Flowmeters:

JIS B 7554(1997), ISO 6817(1992), ISO 9104(1991), NAMUR NE70(2006), ASME MFC-16-2014

nTRADEMARKSHART® is a registered trademark of FieldComm Group.HASTELLOY is a registered trademark of Haynes International Inc.ADMAG, AXG, AXW, BRAIN TERMINAL, FieldMate are registered trademarks of Yokogawa Electric Corporation.Company names and product names used in this material are registered trademarks or trademarks of their respective owners.

Apr. 27, 2017-00