1. THE INFORMATION PRESENTED ON THESE DRAWINGS HAS BEEN DESIGNED AND ANALYZED IN ACCORDANCE WITH THE 2012ONTARIO BUILDING CODE & 2010 NATIONAL BUILDING CODE OF CANADA. CONSTRUCTION IS TO BE PERFORMED IN
ACCORDANCE WITH THIS AND ALL OTHER APPLICABLE CODES.
1.1CONCRETE STRUCTURE DESIGNED IN ACCORDANCE WITH CSA A23.3-04 (R2010)
1.2STEEL STRUCTURE DESIGNED IN ACCORDANCE WITH CAN/CSA-S16-09
1.3 WOOD STRUCTURE DESIGNED IN ACCORDANCE WITH CAN/CSA-086.1-05
1.4MASONRY STRUCTURE DESIGNED IN ACCORDANCE WITH CAN/CSA S304-1(06)
2. GUARDRAILS/HANDRAILS SHALL BE DESIGNED AND CERTIFIED BY THE FABRICATOR'S PROFESSIONAL ENGINEER LICENSED IN
ONTARIO IN ACCORDANCE WITH LOADS PROVIDED IN (4.1.5.15, 3.4.6.4 AND 3.4.6.5 OF THE 2012 ONTARIO BUILDING CODE/2010
NATIONAL BUILDING CODE. STAMPED SHOP DRAWINGS TO BE SUBMITTED. IN ADDITION, GLASS IN GUARDS SHALL COMPLYWITH "SUPPLEMENTARY STANDARD SB-13".
3. THE ROOF HAS BEEN DESIGNED FOR THE REQUIRED STORM WATER FLOW RESTRICTION IN ACCORDANCE WITH 2012 ONTARIO
BUILDING CODE/2010 NATIONAL BUILDING CODE REQUIREMENTS.
4. CONTRACTOR IS TO VERIFY/COORDINATE ALL DIMENSIONS/PENETRATIONS WITH ARCHITECTURAL/MECHANICAL/ELECTRICAL
DRAWINGS PRIOR TO CONSTRUCTION. REPORT INCONSISTENCIES BEFORE PROCEEDING WITH WORK. ANY OPENINGS NOT
INDICATED ON STRUCTURAL DRAWINGS ARE TO BE APPROVED BY STRUCTURAL ENGINEER IN WRITING PRIOR TOCONSTRUCTION.
5. CADD VERSIONS OF THE STRUCTURAL DRAWINGS SHALL BE MADE AVAILABLE TO THE CONTRACTOR UPON THE COMPLETION
OF A RELEASE FORM INDEMNIFYING THE CONSULTANT FROM ANY ERRORS OR OMISSIONS ASSOCIATED WITH THE CADD FILES.
6. LADDERS SHALL BE DESIGNED AND CERTIFIED BY THE FABRICATOR'S PROFESSIONAL ENGINEER LICENSED IN ONTARIO IN
ACCORDANCE WITH LOADS PROVIDED IN PART 4 AND PART 3 OF THE 2012 ONTARIO BUILDING CODE/2010 NATIONAL BUILDING
CODE. STAMPED SHOP DRAWINGS TO BE SUBMITTED.
7. STEEL STAIRS SHALL BE DESIGNED AND CERTIFIED BY THE FABRICATOR'S PROFESSIONAL ENGINEER LICENSED IN ONTARIO IN
ACCORDANCE WITH LOADS PROVIDED IN PART 4 AND PART 3 OF THE 2012 ONTARIO BUILDING CODE/2010 NATIONAL BUILDING
CODE. STAMPED SHOP DRAWINGS TO BE SUBMITTED.
8. SEISMIC RESTRAINT OF ARCH/MECH/ELECT ELEMENTS NOT NOTED ON THE DRAWINGS ARE THE RESPONSIBILITY OF THE
CONTRACTOR'S ENGINEER. RESTRAINT DETAILS ARE TO BE DEVELOPED IN ACCORDANCE WITH THE 2012 OBC/2010 NBC.
CONTRACTOR'S ENGINEER IS RESPONSIBLE FOR THE DESIGN AND DETAILING OF SEISMIC RESTRAINTS AND ISOLATIONS ASREQUIRED BY SPECIFICATIONS INCLUDING THE VERIFICATION THAT THE EXISTING/NEW STRUCTURE IS CAPABLE OF SAFELY
SUPPORTING THE IMPOSED LOADS IN ACCORDANCE WITH THE 2012 OBC/2010 NBC. NO ELEMENTS MAY BE CONSTRUCTEDWITHOUT WRITTEN CONFIRMATION OF THESE CONDITIONS BY CONTRACTOR'S ENGINEER.
9. NO FOUNDATION ELEMENTS ARE TO BE CONSTRUCTED UNTIL WRITTEN APPROVAL OF THE BEARING SURFACES AND
PRESSURES IS PROVIDED BY A GEOTECHNICAL ENGINEER THROUGH ON-SITE INVESTIGATION. FAILURE TO COMPLETE THISWORK COULD RESULT IN THE REMOVAL/REINSTATEMENT OF ANY/ALL FOUNDATION ELEMENTS AT CONTRACTOR'S OWN COST.
10. CONTRACTOR TO PROVIDE PRE-ENGINEERED SHORING AS REQUIRED TO ACCOMMODATE THE CONTRACTOR'S CONSTRUCTION
ACTIVITIES AND TO PREVENT DAMAGE TO ANY ADJACENT PROPERTY. ALL CONSTRUCTION ACTIVITIES TO BE LIMITED TO THELIMITS OF THE CONSTRUCTION SITE AND ALL DAMAGE TO EXISTING PROPERTIES MUST BE REINSTATED.
11. CONTRACTOR IS REQUIRED TO SUBMIT CONDUIT AND SLEEVING SHOP DRAWINGS FOR ALL FLOORS/ROOFS/WALLS/COLUMNS
PRIOR TO THE ERECTION/CONSTRUCTION/FABRICATION OF ANY OF THESE ELEMENTS. THE DRAWINGS ARE TOLOCATE/DIMENSION THE CLEAR SIZES OF OPENINGS/SLEEVES/CONDUITS IN PLAN (FLOORS/ROOFS/COLUMNS) AND ELEVATION
(WALLS/BEAMS). THE COORDINATION OF THE VARIOUS DISCIPLINES/SUBTRADES TO ENSURE ALL ITEMS ARE CLEARLY
INDICATED IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. DRAWINGS ARE TO BE SUBMITTED A MINIMUM OF 4 WEEKSPRIOR TO THE CONSTRUCTION OF THE AFFECTED ELEMENT.
D01-1 GENERAL INFORMATION
D01) GENERAL
D02) GRAVITY LOADS:
REFER TO PLANS FOR LOADS.
D03-1.1 MAIN BUILDING SEISMIC
D03) LATERAL LOADING DATA:
Rd = 1.5Ro = 1.3
. SEISMIC IMPORTANCE FACTOR: (2012 OBC CLAUSE 4.1.8.5)
. SITE CLASS:
PGA: 0.32.RESPONSE SPECTRUM DATA:.5% DAMPED SPECTRAL RESPONSE
ACCELERATION VALUES FOR REFERENCE CITY: (2012 OBC SUPPLEMENTARY STANDARD SB-1)
CLASS 'C': (Fa=1.0:Fv=1.0)
Sa(0.2)
Sa(0.5)Sa(1.0)
Sa(2.0)
= 0.660
= 0.320
= 0.130
= 0.044
= 0.022= 0.044
= 0.130= 0.320
= 0.660= 0.660S(0)
S(0.2)
S(0.5)S(1.0)
S(2.0)
S(4.0)
.
DESIGN SPECTRAL RESPONSE ACCELERATION VALUES (DSRAV): (2012 OBC CLAUSE 4.1.8.4).
REFERENCE CITY: OTTAWA.
SFRS: SYSTEM & CONNECTIONS: (2012 OBC CLAUSE 4.1.8.9/4.1.8.10)
LATERAL LOAD RESISTING SYSTEM: CONVENTIONAL CONSTRUCTION
CSA STANDARD: CAN/CSA CAN/CSA A23.3-04(R10) APPLICABLE CLAUSE(S): 21.8
SFRS: SYSTEM FOUNDATIONS: (2012 OBC CLAUSE 4.1.8.16)
CSA STANDARD: CAN/CSA
APPLICABLE CLAUSE(S):
CONFIRMATION: FOUNDATIONS HAVE BEEN DESIGNED TO RESIST THE LATERAL FORCES APPLIED TO THE SFRS IN ACCORDANCE WITH THE
2012 OBC INCLUDING ALL APPLICABLE AMPLIFICATION FACTORS.
SFRS: DIAPHRAGMS & CONNECTIONS: (2012 OBC CLAUSE 4.1.8.15)
CSA STANDARD: CAN/CSA A23.3-04(R10)
APPLICABLE CLAUSE(S): 21.8
SEISMIC FORCE RESISTING SYSTEM (SFRS).
= 1.0
THE NOTED SITE CLASSIFICATION FOR SEISMIC SITE RESPONSE
AND SHEAR STRENGTH PARAMETERS INDICATED ARE AS
REPORTED IN THE GEOTECHNICAL REPORT
A (SITE SPECIFIC SPECTRUM: )B C D E F
FOR ANCHORED FOOTINGS
FOR UNANCHORED FOOTINGS
PERIOD DATA: (DIRECTION BASED ON DRAWING ORIENTATION).EMPIRICAL PERIOD: (2012 OBC CLAUSE 4.1.8.11.(3) )
SYSTEM RESTRICTION VALUE:. FaSa(0.2) = 0.66 > 0.35 YES
NO
Ta(EMPIRICAL)NS =
MODAL PERIOD: (2012 OBC CLAUSE 4.1.8.11.(3)(d) AND 4.1.8.3.(8))
Ta(MODAL)NS =
Ta(MODAL)EW =
DESIGN PERIODS/MODE & MOMENT FACTORS: (2012 OBC CLAUSE (4.1.8.11(5))
Sa(0.2)
Sa(2.0) = 30 > 8.0 YES
NO
Ta(DESIGN)NS = Mv = 1.0
Ta(DESIGN)EW = Mv = 1.0
Ta(EMPIRICAL)EW =
(a),(b)or(c)
0.40 sec
0.40 sec
0.387 sec
0.387 sec
0.387 sec
0.387 sec
J = 1.0
J = 1.0
VESNS = W * 0.22 = 17,400 KN
MESNS = 230,000 KN • m
NORTH-SOUTH: ( )
. IRREGULARITY REVIEW: (2012 OBC CLAUSE 4.1.8.6)
1. VERTICAL STIFFNESS:
2. WEIGHT:3. VERTICAL GEOMETRIC:
4. IN PLANE DISCONTINUITY:
5. OUT OF PLANE:
6. WEAK STOREY:7. TORSIONAL:
8. NON-ORTHOGONAL:
YES NOYES NO
YES NO
YES NOYES NO
YES NO
YES NO
YES NO
BNS = 1.46BEW = 2.05
CONCLUSION: BUILDING IS REGULAR IRREGULARDYNAMIC ANALYSIS: REQUIRED NOT REQUIRED
BASE SHEARS/MOMENTS:.
EQUIVALENT STATIC (ES)
FORCE PROCEDURE
EAST-WEST: ( )
DYNAMIC ANALYSIS (DYI) PROCEDURE
VMAX = S(0.2) W/(RdRo) = W * 0.22 = 17,400 KN2
3
DESIGN FUNDAMENTAL PERIOD BASED DSRAV: (2012 OBC CLAUSE 4.1.8.11(2)). S(Ta)NS = 0.442
S(Ta)EW = 0.442
DYNAMIC PROCEDURE: METHOD: MODAL RESPONSE SPECTRUM NUMERICAL INTEGRATION TIME HISTORY N/A
VMIN = S(2.0)MV W/(RdRo) = W * 0.03 = 2,400 KN
TORSIONAL ECCENTRICITY:
± 0.10 Dnx (4.1.8.12(4a), B 1.7) >
± 0.05 Dnx (4.1.8.12(4b), B 1.7, 3-D DYNAMIC ANALYSIS)<
± 0.10 Dnx (4.1.8.11(10a), B 1.7 EQUIV. STATIC FORCE PROCEDURE)
VSTATIC = S(Ta)MV W/(RdRo)
<.
STRUCTURAL SEPARATION: THE ADJACENT STRUCTURES HAVE BEEN SEPARATED IN ACCORDANCE WITH 4.1.8.14(1) OF
THE 2012 O.B.C.
.N/A
STATIC MAXIMUM/MINIMUM VALUES:.NORTH-SOUTH: ( )
EAST-WEST: ( )
VMAX = S(0.2) W/(RdRo) = W * 0.22 = 17,400 KN2
3
VMIN = S(2.0)MV W/(RdRo) = W * 0.03 = 2,400 KN
DESIGN (D) LOADS
S.F. = g ٠Ie
RdRo= g 0.513٠
VDYINS = 11,200 KN
MDYINS = 140,000 KN • m
MPMR = 95.7 %
VDNS = 17,600 KN
MDNS = 220,000 KN • m
VDYIEW = 13,700 KN
MDYIEW = 180,000 KN • m
MPMR = 98.9 %
VDEW = 17,400 KN
MDEW = 230,000 KN • m
SEISMIC LOADS
NOTES:
(1) INITIAL DYNAMIC LOAD SCALING FACTOR
DYNAMIC ANALYSIS PROCEDURE LOADS ARE BASED ON THE EVALUATION OF THE BUILDING WITH THE INITIAL
SCALING FACTOR APPLIED. WHEN USED THESE ARE COMPARED TO THE STATIC FORCE VALUE IN ACCORDANCEWITH 4.1.8.12(6)-(7) TO DETERMINE DESIGN LOAD VALUES.
(2) DESIGN LOAD SHEAR VALUES ARE BASED ON THE EVALUATION OF VES AND VDYI IN ACCORDANCE WITH 4.1.8.12
(5),(6) AND (7) OF THE 2012 OBC. LOADS INDICATED SHOW THE DESIGN BASE SHEAR AND CORRESPONDING
OVERTURNING MOMENT.
(3) N/A = NOT USED IN THE DESIGN OF THE BUILDING.
BUILDING WEIGHT FOR SEISMIC DESIGN:. W = 80,000 KN
(1)(3) (2)
2012 OBC CLAUSE 4.1.8.11(1)-(10) 2012 OBC CLAUSE 4.1.8.12(1)-(5)
VESEW = W * 0.22 = 17,400 KNMESEW = 230,000 KN • m
NON-ORTHOGONAL EFFECTS
HAVE BEEN CONSIDERED IN
ACCORDANCE WITH 2012 OBCCLAUSE 4.1.8.8 (c)
YES
N/A
NORTH-SOUTH: ( ) NORTH-SOUTH: ( )
(INITIAL SCALING FACTOR)
NON-ORTHOGONAL EFFECTS
HAVE BEEN CONSIDERED IN
ACCORDANCE WITH 2012 OBCCLAUSE 4.1.8.8 (c)
YES
N/A
EAST-WEST: ( )EAST-WEST: ( )
D03-2.1 TEST FACILITY: SEISMIC
UNLESS OTHERWISE OUTLINED IN GEOTECTNICAL REPORT DO NOT EXCAVATE BELOW A LINE EXTENDING
DOWNWARD FROM ANY BEARING STRATA AT A SLOPE OF 1 VERTICAL TO 2 HORIZONTAL. ADJUST FOOTING
AND TRENCH ELEVATIONS TO MEET THIS REQUIREMENT (SEE DIAGRAM).
EXCAVATION
12
FOUNDATIONEXISTING
NEW
ALL FOOTINGS TO BEAR ON UNDISTURBED NATIVE MATERIAL WITH MINIMUM ALLOWABLE BEARING STRENGTHS AS NOTED ON
PLANS / SCHEDULES / SECTIONS AND AS APPROVED BY GEOTECHNICAL ENGINEER ON SITE.
REFERENCE GEOTECHNICAL REPORT: PG 3563-2 (R1)
REPORT AUTHOR: PATERSON GROUP
LOCATIONS OF FOOTING STEPS TO BE APPROVED BY ENGINEER IN WRITING PRIOR TO CONSTRUCTION.
D03-3 DEFINITIONS:
THE FOLLOWING ABBREVIATIONS HAVE BEEN USED IN THESE NOTES AND DRAWINGS:
AT (SPACING c/c)
ARCHITECTURAL
BOTTOM
BOTTOM LOWER LAYER
BOTTOM UPPER LAYER
CENTRE TO CENTRE
CENTRE LINE
CONTINUOUS
CORE WALL
EACH
EACH END
EACH FACE
ELEVATION
EACH SIDE
EACH WAY
FAR FACE
HORIZONTAL
HEAVY DUTY GALVANIZED TRUSS
TYPE MASONRY REINFORCEMENT
INSIDE FACE
LOWER LAYER
METRES
MILLIMETRESMAXIMUM
MECHANICAL
MINIMUM
NEAR FACE
NOT TO SCALE
OUTSIDE FACE
PILE CUT-OFFPLATE
STANDARD GALVANIZED LADDER
MASONRY REINFORCEMENTS
SHEARWALL
TOP
TOP LOWER LAYER
TOP UPPER LAYER
TOP OF PILE CAP
TYPICAL
UNLESS OTHERWISE NOTED
UPPER LAYER
UNDERSIDE
VERTICAL
D31) FOUNDATIONS:
D31-1 FOOTINGS:
D31-3 PROTECT LATERAL STABILITY OF BEARING STRATA UNLESS NOTED:
D31-4 FOOTINGS STEPS:
@
ARCH.
B BLL
BUL
c/c
C
CONT.
CW
EA.
EE EF
EL.
ES
EW
FF
H
HDMR
IF
LL
m
mm
MAX.
MECH
MIN.
NF
NTS
OF
PCO
SMR
SWT TLL
TUL
TOPC
TYP.U/N
UL
U/S V
1. SUBMIT SHOP DRAWINGS FOR ALL STRUCTURAL WORK AND ANY WORK AFFECTING THE STRUCTURE TO THE CONSTRUCTION
MANAGER. OBTAIN ARCHITECT'S & ENGINEER'S APPROVAL BEFORE PROCEEDING WITH THE FABRICATION.
2. EACH OF THE FOLLOWING SHOP DRAWINGS MUST BEAR THE SIGNATURE AND STAMP OF A QUALIFIED PROFESSIONAL ENGINEER
REGISTERED IN THE PROVINCE (PLUS OTHER DRAWINGS AS NOTED).
a) DRAWINGS FOR ANY TEMPORARY WORK.
b) DRAWINGS FOR ANY STRUCTURAL PARTS DESIGNED BY THE CONTRACTOR'S FORCES INCLUDING EXTERIOR BUILDING
ENVELOPE.
c) STRUCTURAL STEEL/JOISTS.
d) FORMWORK
3. SHOP DRAWINGS MUST BE REVIEWED AND STAMPED REVIEWED BY THE CONTRACTOR BEFORE ISSUING TO THE
ARCHITECT/ENGINEER. SHOP DRAWINGS NOT STAMPED BY THE CONTRACTOR WILL BE REJECTED. ANY DELAYS IN THE
CONSTRUCTION SCHEDULE DUE TO NONCOMPLIANCE WITH THIS REQUIREMENT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
4. SUBMIT STRUCTURAL STEEL, STEEL JOIST AND STEEL DECK SHOP DRAWINGS FOR STRUCTURAL ENGINEER'S REVIEW BEFORE
FABRICATION. ALL SHOP DRAWINGS SHALL BEAR THE SEAL OF A REGISTERED PROFESSIONAL ENGINEER IN THE PROVINCE OF
ONTARIO.
5. SHOP DRAWINGS ARE REVIEWED FOR CONFORMANCE WITH THE GENERAL DESIGN CONCEPT. THIS REVIEW DOES NOT IMPLY
APPROVAL OF THE DETAILED DESIGN OR QUANTITIES DESCRIBED IN THE SHOP DRAWINGS. THE RESPONSIBILITY FOR THE
QUANTITIES AND DETAILED DESIGN OF THE MATERIALS AND COMPONENTS AS REQUIRED TO PROVIDE THE COMPLETE AND
SATISFACTORY JOB DESCRIBED IN THE DESIGN DOCUMENTS REMAINS WITH THE CONTRACTOR.
6. CONTRACTOR IS REQUIRED TO SUBMIT CONDUIT AND SLEEVING SHOP DRAWINGS FOR ALL FLOORS/ROOFS/WALLS/COLUMNS PRIOR
TO THE ERECTION/CONSTRUCTION/FABRICATION OF ANY OF THESE ELEMENTS. THE DRAWINGS ARE TO LOCATE/DIMENSION THE
CLEAR SIZES OF OPENINGS/SLEEVES/CONDUITS IN PLAN (FLOORS/ROOFS/COLUMNS) AND ELEVATION (WALLS/BEAMS). THE
COORDINATION OF THE VARIOUS DISCIPLINES/SUBTRADES TO ENSURE ALL ITEMS ARE CLEARLY INDICATED IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR. DRAWINGS ARE TO BE SUBMITTED A MINIMUM OF 4 WEEKS PRIOR TO THE CONSTRUCTION OF
THE AFFECTED ELEMENT.
D03-4 SHOP DRAWINGS
D31-2 EXCAVATION , FOUNDATIONS AND BACKFILL:
1. REFER TO GEOTECHNICAL REPORT FOR ALL REQUIREMENTS (ADDITIONAL REQUIREMENTS AS NOTED BELOW).
GEOTECHNICAL REPORT RECOMMENDATIONS GOVERN.
2. PRIOR TO ANY EXCAVATION, VERIFY LOCATION OF EXISTING SERVICES AND TAKE ALL NECESSARY MEASURES TO MAINTAIN
SERVICES WHERE REQUIRED. NOTIFY OWNER AND ENGINEER IF ANY SERVICES NOT SHOWN ON PLAN OR OTHERWISE
EXPECTED ARE ENCOUNTERED. DO NOT PROCEED FURTHER UNTIL DIRECTED.
3. CARE MUST BE TAKEN TO AVOID UNDERMINING EXISTING BUILDING FOUNDATIONS OR UNDERGROUND SERVICES.
4. PROTECT SUB-GRADE FROM FREEZING AND FROST ACTION AT ALL TIMES DURING CONSTRUCTION.
5. FOOTINGS MUST BEAR ON APPROVED BEARING SURFACES.
6. BACKFILL TO WITHIN 200mm OF UNDERSIDE OF SLAB WITH GRANULAR 'B' TYPE II IN LAYERS UP TO 12" THICK, COMPACTED TO
MINIMUM 100% SPMDD OR AS PER GEOTECHNICAL REPORT.
7. FINAL 200mm UNDER SLAB TO BE GRANULAR 'A' COMPACTED TO MINIMUM 100% SPMDD OR AS PER GEOTECHNICAL REPORT.
8. RE-USE OF EXCAVATED GRANULAR MATERIAL IS SUBJECT TO APPROVAL OF GEOTECHNICAL CONSULTANT.
NOTES:
1. IF 'D' EXCEEDS 1800 PROVIDE
HORIZONTAL SECTIONS OF 1200
MINIMUM LENGTH BETWEEN EVERY
SET OF STEPS.
2. STEPPED FOOTINGS SHALL BE CAST
AS A SINGLE UNIT.
3. 'T' DENOTES FOOTING THICKNESS.
FOOTING REINFORCEMENT
WHEN REQUIRED REFER TO
FOUNDATION PLAN
7 (MAX.)
10
1800900
(MIN.)
600
(MA
X.)
D
CLASS 'B'LAP SPLICE
(600 MIN.)
CLASS 'B'
LAP SPLICE(MIN. 600)
75 CLE
AR
T O
R150 M
IN.
T OR225 MIN.
T OR225 MIN.
T
T O
R
150 MIN
.
UNDISTURBED
SOIL/APPROVED
BEARING SOIL
600
WIND:
q= 0.41 KPa
(1 IN 50 YEARS)
= 1.0 (ULS) = 0.75 (SLS)
NORTH-SOUTH: ( )
Vbase = 80 KN
Mbase = 160 KN • m
EAST-WEST: ( )
Vbase = 110 KNMbase = 260 KN • m
@ HEATED BUILDINGS: 1500mm (5'-0")
@ HEATED BUILDING (SNOW CLEARED): 1800mm (6'-0")
@ ISOLATED AREAS: 2100mm (7'-0")
(NOTE: INCREASE DEPTHS AS REQUIRED BY GEOTECHNICAL REPORT/ENGINEER)
(NOTE: ONLY TO BE USED AFTER WRITTEN APPROVAL BY ENGINEER/WHERE GEOTECHNICAL REPORT REQUIRES
MORE SOIL COVER/EXTENTS OF INSULATION, SOILS REPORT GOVERNS)
UNDISTURBED SOIL/
ENGINEERED FILL
FOOTING
(REFER TO PLANS) 400 (
16")
MIN
.
1200(4'-0") VARIES 1200(4'-0")
50mm(2") OF APPROVED
COMPRESSIBLE MATERIAL
10 MPa(1500psi) LEAN
MIX CONCRETE
WALL STRIP FOOTING
(NOTE: LOCATIONS WHERE PIPES CROSS BELOW FOOTINGS ARE TO BE APPROVED BY ENGINEER IN
WRITING PRIOR TO CONSTRUCTION. ENGINEER RESERVES THE RIGHT TO RELOCATE PIPES AS REQUIRED
OR LOWER FOOTINGS TO SUIT.)
50mm(2") HI 100
RIGID INSULATION
D31-7 PIPE CROSING BELOW STRIP FOOTING:
D31-5 MINIMUM FROST COVER REQUIREMENTS:
D31-6 ALTERNATE FROST COVER DETAIL
1. SPACING OF BARS SHALL BE APPROXIMATELY UNIFORM WITHIN THE CORRESPONDING STRIPS. DO NOT
ELIMINATE OR DISPLACE REINFORCEMENT TO ACCOMMODATE HARDWARE. IF INSERTS CANNOT BE LOCATED AS
SPECIFIED, OBTAIN APPROVAL OF ALL MODIFICATIONS FROM ENGINEER BEFORE THE PLACING OF CONCRETE.
2. WHERE TENSION LAPS ARE SPECIFIED, LAP REINFORCING STEEL IN ACCORDANCE WITH THE REQUIREMENTS OF
CAN3-A23.3, LATEST EDITION. ALL OTHER LAPS AND EMBEDMENT OF DOWELS SHALL BE 24 BAR DIAMETERS, BUT
NOT LESS THAN 600mm IF NOT SPECIFIED OTHERWISE. WIRE MESH LAPS SHALL BE 150mm MINIMUM.
TYPICAL REBAR REQUIREMENTS:
LAPS: AS ON DRAWINGS
BAR DESIGNATION IN SLABS:
METRIC: 10-15M 6400/4100 T MEANS 10 BARS, SIZE 15M, TOP OF SLAB, 5-6400 LONG / 5-4100 LONG ALTERNATING
(+ HOOK LENGTH FOR TOP BARS @ SLAB EDGES)
IMPERIAL: 10-15M 150/086 MEANS 10 BARS, SIZE 15M, TOP OF SLAB, 5-15'-0" LONG / 5-8'-6" LONG ALTERNATING
(+HOOK LENGTH FOR TOP BARS @ SLAB EDGES)
PROVIDE HOOKS WHERE TOP BARS TERMINATE AT EDGES. PROVIDE HOOKS ON BOTTOM BARS WHERE NOTED AND
AT ALL CANTILEVER ENDS.
> 36 BAR DIA. > 1.5 d
> 600mm(24")
D03) CONCRETE
D03-1 CONCRETE COVER (CLEAR TO REINFORCING):
U/S FOOTINGS, PILE CAPS, GRADE BEAMS (AGAINST SOIL)
FOOTINGS, PILE CAPS, GRADE BEAMS (SIDES & TOP)
WALLS
SLABS
BEAMS
COLUMNS
BALCONIES
PROVIDE 32mm (114") COVER FOR BOTTOM STEEL FOR SLAB ABOVE 3HR, FIRE RATED AREAS. PROVIDE
50mm (2") COVER FOR COLUMN TIES IN 3HR, FIRE RATED AREAS.
75mm (3")
50mm (2")
40mm (112")
25mm (1") U/N
40mm (112")(TO STIRRUPS)
40mm (112")(TO TIES)
40mm (112")(TO TOP STEEL)
D03-2 SLAB REINFORCING STEEL:
1. AT SLAB EDGES AND OPENINGS CARRY ALL TOP BARS TO 50mm (2") FROM SLAB EDGE AND PROVIDE
STANDARD 90 OR 180 DEGREE HOOKS.
2. EXTEND BOTTOM BARS TO 50mm (2") FROM SLAB EDGES/OPENINGS.
3. EXTEND BOTTOM BARS MINIMUM 150mm (6") PAST OF SUPPORT AT ALL ENDS AND SINGLE SPANS
SUPPORTED ON WALLS/BEAMS.
4. WHERE 150mm (6") EMBEDMENT IS NOT POSSIBLE PROVIDE STANDARD 90 DEGREE HOOK LAID FLAT.
5. IN TWO-WAY SLABS WITHOUT BEAMS, MINIMUM LENGTH OF TOP/BOTTOM BARS IS TO BE AS PER REINFORCING
STEEL MANUAL FOR STANDARD PRACTICE (SECTION 5). REFER ALSO TO TYPICAL CS/MS LAYOUTS.
6. COLUMN STRIP WIDTH ON EACH SIDE OF COLUMN IS A SHOWN ON PLANS. REFER ALSO TO TYPICAL STRIP
DETAIL.
7. PLACE STRUCTURAL INTEGRITY BARS WITHIN WIDTH OF COLUMN OR CAPITAL, IN ACCORDANCE WITH
STRUCTURAL INTEGRITY STEEL TYPICAL DETAIL. PLACE OTHER BARS IN REMAINING WIDTH OF COLUMN STRIP.
8. PROVIDE CHAIRS AND BAR SUPPORTS IN ACCORDANCE WITH RSIC DETAILING MANUAL.
9. PLACE LONG AND SHORT BARS ALTERNATING.
10. PLACE BARS UNIFORMLY DISTRIBUTED EXCEPT A) PLACE AT LEAST 50% OF TOP BARS IN COLUMN STRIP
WITHIN SUPPORT WIDTH PLUS SLAB THICKNESS EACH SIDE OF COLUMN FACE OR EDGE OF COLUMN CAPITAL.
B) WHERE NOTED OTHERWISE ON PLAN.
11. BAR LENGTHS ARE AS SHOWN, UNLESS NOTED OTHERWISE ON PLAN.
D03-3 MINIMUM LENGTH OF SLAB REINFORCEMENT:
S000
A
SCALE: N.T.S.
SECTION: STEPPED FOOTING DETAIL
S000
C
SCALE: N.T.S.
SECTION: PIPE CROSSING BELOW STRIP FOOTING
3. Ln IS THE LONGER OF ADJACENT CLEAR SPANS FROM COLUMN OR CAPITAL FACE.
4. COLUMN STRIP WIDTH ON EACH SIDE OF COLUMN IS A SHOWN IN TYPICAL DETAIL, UNLESS NOTED
OTHERWISE ON PLAN.
5. PLACE STRUCTURAL INTEGRITY BARS WITHIN WIDTH OF COLUMN OR CAPITAL, IN ACCORDANCE WITH
STRUCTURAL INTEGRITY STEEL TYPICAL DETAIL. PLACE OTHER BARS IN REMAINING WIDTH OF COLUMN
STRIP.
6. 4. PROVIDE CHAIRS AND BAR SUPPORTS IN ACCORDANCE WITH ACI DETAILING MANUAL.
7. 5. PLACE LONG AND SHORT BARS ALTERNATING.
8. 6. PLACE BARS UNIFORMLY DISTRIBUTED EXCEPT A) PLACE AT LEAST 50% OF TOP BARS IN COLUMN
STRIP WITHIN SUPPORT WIDTH PLUS SLAB THICKNESS EACH SIDE OF COLUMN FACE OR EDGE OF
COLUMN CAPITAL. B) WHERE NOTED OTHERWISE ON PLAN.
9. BAR LENGTHS ARE AS SHOWN, UNLESS NOTED OTHERWISE ON PLAN.
10. TERMINATE TOP BARS AT DISCONTINUOUS EDGE IN STANDARD 90 DEGREE HOOK, OR EXTEND INTO
ADJACENT SLAB, IN ACCORDANCE WITH ONE-WAY SLAB DETAILS.
11. EXTEND BOTTOM BARS TO 75 (3) OF DISCONTINUOUS EDGE WITH NO SPANDREL BEAMS, OR EXTEND 150
(6) MINIMUM INTO SPANDREL BEAM. AT CONTINUOUS DROP EXTEND ALTERNATE BARS TO 75 (3) OF EDGE
AND 150 (6) INTO CONTINUOUS DROP.
1. PROVIDE ADDITIONAL INTEGRITY BARS IN THE BOTTOM OF SLABS, CENTRED ON EACH COLUMN.
2. INTEGRITY BARS SHALL BE AS INDICATED ON REINFORCING PLANS.
D03-4 INTEGRITY BARS:
(.0025Ag) (.0025Ag)
1. PROVIDE UPWARD SLAB AND BEAM CAMBERS AS INDICATED ON PLANS. CAMBER BOTH THE UNDERSIDE AND TOP
OF CONCRETE IN A PARABOLIC PROFILE SO AS TO MAINTAIN THE STRUCTURAL THICKNESSES SHOWN. ADJUST
CAMBERS AS DIRECTED BY CONSULTANT FOR "NON-TYPICAL BAYS" BASED ON SPAN AND SUPPORT CONDITIONS.
2. PRIOR TO CONCRETING VERIFY FORMWORK IN PLACE CAMBERS BY SURVEY AND REPORT THE RESULTS TO THE
ARCHITECT. (REFER ALSO TO SPECIFICATIONS FOR SURVEYING REQUIREMENTS).
3. PLACE, SCREED AND FINISH SLAB CONCRETE TO SPECIFIED SLAB AND BEAM THICKNESSES.
4. CARRY OUT SURVEYING IN ACCORDANCE WITH THE SPECIFICATIONS. CAMBERS ON SUBSEQUENT FLOORS MAY
BE ADJUSTED TO SUIT THE ACTUAL BEHAVIOUR OF FIRST TYPICAL FLOOR SLABS. REPEAT ITEMS 2 & 3 AS
REQUIRED.
5. WHERE NOT NOTED ABOVE OR ON PLANS, CAMBER BEAMS FOR SPAN/500 (SPAN DEFINED AS CENTRELINE TO
CENTRELINE OF SUPPORTS).
6. FOR SLAB CAMBERS ON UPPER FLOORS REFER TO PLANS.
CORNER BARS SAME SIZE AND
SPACING AS HORIZONTAL WALL
BARS.
4-20M VERT.
4-20M VERT.
STANDARD HOOK
>
>
D03-5 TYPICAL CAMBERING REQUIREMENTS:
D03-7 MINIMUM WALL REINFORCING:
D03-8 HORIZONTAL WALL STEEL DETAIL AT CORNERS U/N:
(NON-SHEAR WALL LOCATIONS)
TYPICAL CORNER
UNLESS OTHERWISE NOTED PROVIDE:
WALL
THICKNESS
VERTICAL
BARS
HORIZONTAL
BARS
VERTICAL
EACH END
150mm(6")200mm(8")250mm(10")300mm(12")350mm(14")400mm(16")
10M @ 250(10")15M @ 400(16")10M @ 300(12") EF10M @ 250(10") EF15M @ 450(18") EF15M @ 400(16") EF
10M @ 250(10")15M @ 400(16")10M @ 300(12") EF10M @ 250(10") EF15M @ 450(18") EF15M @ 400(16") EF
1-15M1-20M2-20M2-20M2-25M2-25M
REFER TO MECHANICAL
DWGS FOR SIZES AND
LOCATIONS• 1-15M H.E.F.
CONT. @ TOP
• 15M @ 300(12")
H.E.F.
ROUGHEN CONCRETE USING
BUSH HAMMER TECHNIQUE
ROUGHEN/CLEAN/WET
EXISTING SURFACE PRIOR
TO CONCRETE PLACEMENT.
10
0(4
")
HILTI HY-150
EPOXY ADHESIVE
10M @ 300(12")o.c. E.W.
(+1 ADD'L T&B AROUND
PERIMETER)
100
(4")
REFER TO MECHANICAL DWGS FOR
SIZES AND LOCATIONS
10M @ 500(20") @
PERIMETER
≤1
00
(4")
≥
D03-6 SLAB BAND
PLACE ALL COLUMN STRIP BOTTOM
STEEL CALLED UP ON PLAN IN
BOTTOM OF SLAB BAND
PROVIDE ADDITIONAL BOT. TIE BARS
10M @ 500(20")o.c. BOTTOM UPPER
LAYER.
ADD ADDITIONAL 15M @
400(16") BOT. IN PORTION OF
COLUMN STRIP OUTSIDE
REGION OF SLAB BAND.
S000
L
SCALE: N.T.S.
SECTION: HORIZONTAL WALL STEEL DETAIL @ CORNERS U/N
S000
M
SCALE: N.T.S.
TYPICAL MECHANICAL PADS
S000
N
SCALE: N.T.S.
TYPICAL MECHANICAL PADS: CURBS
≥
15M @ 400(16")
V.E.F.
• 1-15M H.E.F. CONT.
@ TOP
• 15M @ 300(12") H.E.F.
15M @ 400(16")
VERT.
S000
G
SCALE: N.T.S.
TYPICAL SLAB BAND
OPENING UP TO
300x300 (12"x12")
1-15M x 1000 (3'-4")
LONG IN MIDDLE OF
SLAB
1-15M x 1000 (3'-4")
LONG IN MIDDLE OF
SLAB
D03-7 TYPICAL TRIMMING DETAIL OF OPENING IN SLAB (U/N)
OPENINGS < 300x300(12"x12")
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE EQUIVALENT AREA OF STEEL
(BASED ON TERMINATED BARS) E.S. OF
OPENING @ 12 SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
SLAB AND WALL OPENINGS:
1. DISPLACE BARS LATERALLY AT SLAB OPENINGS. D O N O T C U T. PLACE HALF OF DISPLACED BARS EACH SIDE OF
OPENING AND INFILL BETWEEN WITH BARS OF MATCHING SIZE & SPACING
2. PROVIDE 3-15M @ 150mm (6") o.c. TOP AND BOTTOM MINIMUM ADDITIONAL REINFORCEMENT AROUND SLAB OPENINGS
300x300 (12"x12") OR LARGER (UNLESS NOTED). EXTEND 24 BAR DIAMETER (600mm (24") MIN.) BEYOND CORNERS.
3. PROVIDE THE FOLLOWING MINIMUM ADDITIONAL REINFORCEMENT AROUND WALL OPENINGS 300x300 (12"x12") OR LARGER
(UNLESS NOTED). EXTEND 24 BAR DIAMETER BEYOND CORNERS EACH WAY.
200(8") WALLS: 1-20M
250(10") WALLS: 2-20M E.F
300(12") OR THICKER WALLS: 2-20M E.F.
4. SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS TO THOSE INDICATED.
5. PROVIDE OPENINGS IN WALLS AND SLABS AS SHOWN ON STRUCTURAL DRAWINGS OR OTHERWISE REQUIRED BY VARIOUS
TRADES. ENGINEER'S APPROVAL MUST BE OBTAINED FOR LOCATIONS AND SIZES OF OPENINGS NOT SHOWN ON
STRUCTURAL DRAWINGS. ALL OPENINGS MUST BE FORMED BEFORE THE SLAB OR WALL IS POURED. DO NOT CUT ANY
OPENINGS, AFTER CONCRETING, UNLESS SPECIFICALLY AUTHORIZED BY THE ENGINEER.
6. PROVIDE SLEEVES IN SLABS OR WALLS FOR MECHANICAL PIPING AND AVOID OPENINGS WHERE POSSIBLE. ENGINEER'S
APPROVAL MUST BE OBTAINED FOR ANY CONCENTRATION OF SLEEVES IN COLUMN BAND AND AROUND COLUMN. SLEEVING
DRAWINGS MUST BE SUBMITTED FOR APPROVAL MINIMUM OF TWO WEEKS PRIOR TO POURING OF CONCRETE.
S000
H
SCALE: N.T.S.
OPENINGS < 300x300(12"x12")
TRIMMING NOTES:
1. SEE STRUCTURAL PLANS FOR APPROXIMATE SIZE AND LOCATION OF OPENINGS AND ARCH./MECH/ELECT. DRAWINGS
FOR EXACT DIMENSIONS.
2. IF OPENINGS LARGER THAN 300 (1'-0") WIDE ARE REQUIRED AND ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS
THE ENGINEER MUST BE INFORMED SO PROPER DETAILS CAN BE SUPPLIED.
3. UNLESS OTHERWISE NOTED OPENINGS SMALLER THAN 200x200 (8"x8") DO NOT REQUIRE TRIMMER BARS.
4. SLEEVES SHALL NOT BE PLACED NEAR COLUMNS, CAPITALS, OR DROP PANELS, UNLESS ENGINEER IS NOTIFIED.
5. INCREASE BAR LENGTHS BY 20% FOR EPOXY REBAR.
6. INFORM ENGINEER IF ANY SLEEVES EXCEED 200mm(8")Ø.
7. ALL SLEEVES SHALL BE COORDINATED WITH SUB-CONTRACTORS AND BE INDICATED ON REBAR SHOP DRAWINGS.
8. SLEEVE MAY NOT BE PLACED IN SLABS OR WALLS UNLESS APPROVED BY ENGINEER. CONTRACTOR TO SUBMIT
SLEEVE LAYOUT DRAWINGS A MINIMUM OF 4 WEEKS PRIOR TO CONCRETING.
9. SLEEVE NOT APPROVED BY ENGINEER SHALL BE REMOVED/RELOCATED AS DIRECTED BY ENGINEER AT THE
CONTRACTOR'S OWN EXPENSE.
1-15M x 1000 (3'-4") LONG IN
MIDDLE OF SLAB
1-15M IN MIDDLE
OF SLAB
450(18") MIN.100(4")
CLEAR MIN.450(18") MIN.
TERMINATE AFFECTED STEEL @ FACE OF OPENING (c/w:
HOOK) BARS ARE TO EXTEND FULL LENGTH NOTED ON
DRAWINGS (MIN. 1200mm (4'-0") FROM FACE OF OPENING)
PROVIDE 3-20M @ 150(6") ADD'L E.S.
OF OPENING (EXTEND 1200mm (4'-0")
PAST EDGE)
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
S000
I
SCALE: N.T.S.
BOTTOM STEEL: OPENINGS ≤ 1200x1200(4'-0"x4'-0")
S000
J
SCALE: N.T.S.
TOP STEEL: OPENINGS ≤ 1200x1200(4'-0"x4'-0")
S000
K
SCALE: N.T.S.
SLEEVES ≤ 200mm (8") DIA.INTEGRITY STEEL (SEE PLAN FOR TYPE/NUMBER OF BARS:
Rd = 1.5Ro = 1.3
. SEISMIC IMPORTANCE FACTOR: (2012 OBC CLAUSE 4.1.8.5)
. SITE CLASS:
PGA: 0.32.RESPONSE SPECTRUM DATA:.5% DAMPED SPECTRAL RESPONSE
ACCELERATION VALUES FOR REFERENCE CITY: (2012 OBC SUPPLEMENTARY STANDARD SB-1)
CLASS 'C': (Fa=1.0:Fv=1.0)
Sa(0.2)
Sa(0.5)
Sa(1.0)
Sa(2.0)
= 0.660
= 0.320
= 0.130
= 0.044
= 0.022= 0.044= 0.130
= 0.320
= 0.660= 0.660S(0)
S(0.2)
S(0.5)
S(1.0)
S(2.0)S(4.0)
.
DESIGN SPECTRAL RESPONSE ACCELERATION VALUES (DSRAV): (2012 OBC CLAUSE 4.1.8.4).
REFERENCE CITY: OTTAWA.
SFRS: SYSTEM & CONNECTIONS: (2012 OBC CLAUSE 4.1.8.9/4.1.8.10)
LATERAL LOAD RESISTING SYSTEM: CONVENTIONAL CONSTRUCTION
CSA STANDARD: CAN/CSA CAN/CSA S16-01(09) / A23.3-04 (10)
APPLICABLE CLAUSE(S): 27.10
SFRS: SYSTEM FOUNDATIONS: (2012 OBC CLAUSE 4.1.8.16)
CSA STANDARD: CAN/CSA APPLICABLE CLAUSE(S):
CONFIRMATION: FOUNDATIONS HAVE BEEN DESIGNED TO RESIST THE LATERAL
FORCES APPLIED TO THE SFRS IN ACCORDANCE WITH THE
2012 OBC INCLUDING ALL APPLICABLE AMPLIFICATION FACTORS.
SFRS: DIAPHRAGMS & CONNECTIONS: (2012 OBC CLAUSE 4.1.8.15)
CSA STANDARD: CAN/CSA S16-01(09) APPLICABLE CLAUSE(S): 27.10
SEISMIC FORCE RESISTING SYSTEM (SFRS).
= 1.0
THE NOTED SITE CLASSIFICATION FOR SEISMIC SITE RESPONSE
AND SHEAR STRENGTH PARAMETERS INDICATED ARE ASREPORTED IN THE GEOTECHNICAL REPORT
A (SITE SPECIFIC SPECTRUM: )B C D E F
FOR ANCHORED FOOTINGS
FOR UNANCHORED FOOTINGS
PERIOD DATA: (DIRECTION BASED ON DRAWING ORIENTATION).EMPIRICAL PERIOD: (2012 OBC CLAUSE 4.1.8.11.(3) )
SYSTEM RESTRICTION VALUE:. FaSa(0.2) = 0.66 > 0.35 YES
NO
Ta(EMPIRICAL)NS =
MODAL PERIOD: (2012 OBC CLAUSE 4.1.8.11.(3)(d) AND 4.1.8.3.(8))
Ta(MODAL)NS =
Ta(MODAL)EW =
DESIGN PERIODS/MODE & MOMENT FACTORS: (2012 OBC CLAUSE (4.1.8.11(5))
Sa(0.2)
Sa(2.0) = 30 > 8.0 YES
NO
Ta(DESIGN)NS = Mv = 1.0
Ta(DESIGN)EW = Mv = 1.0
Ta(EMPIRICAL)EW =
(a),(b)or(c)
0.13 sec
0.13 sec
N/A
N/A
0.13 sec
0.13 sec
J = 1.0
J = 1.0
VESNS = W * 0.22 = 1,200 KNMESNS = 5,100 KN • m
NORTH-SOUTH: ( )
. IRREGULARITY REVIEW: (2012 OBC CLAUSE 4.1.8.6)
1. VERTICAL STIFFNESS:
2. WEIGHT:
3. VERTICAL GEOMETRIC:
4. IN PLANE DISCONTINUITY:5. OUT OF PLANE:
6. WEAK STOREY:
7. TORSIONAL:
8. NON-ORTHOGONAL:
YES NO
YES NO
YES NOYES NO
YES NO
YES NOYES NO
YES NO
BNS = N/A
BEW = N/A
CONCLUSION: BUILDING IS REGULAR IRREGULARDYNAMIC ANALYSIS: REQUIRED NOT REQUIRED
BASE SHEARS/MOMENTS:.
EQUIVALENT STATIC (ES)
FORCE PROCEDURE
EAST-WEST: ( )
DYNAMIC ANALYSIS (DYI) PROCEDURE
VMAX = S(0.2) W/(RdRo) = W * 0.22 = 1,200 KN2
3
DESIGN FUNDAMENTAL PERIOD BASED DSRAV: (2012 OBC CLAUSE 4.1.8.11(2)). S(Ta)NS = 0.64
S(Ta)EW = 0.64
DYNAMIC PROCEDURE: METHOD: MODAL RESPONSE SPECTRUM NUMERICAL INTEGRATION TIME HISTORY N/A
VMIN = S(2.0)MV W/(RdRo) = W * 0.03 = 150 KN
TORSIONAL ECCENTRICITY:
± 0.10 Dnx (4.1.8.12(4a), B 1.7) >
± 0.05 Dnx (4.1.8.12(4b), B 1.7, 3-D DYNAMIC ANALYSIS)<
± 0.10 Dnx (4.1.8.11(10a), B 1.7 EQUIV. STATIC FORCE PROCEDURE)
VSTATIC = S(Ta)MV W/(RdRo)
<.
STRUCTURAL SEPARATION: THE ADJACENT STRUCTURES HAVE BEEN SEPARATED IN ACCORDANCE WITH 4.1.8.14(1) OFTHE 2012 O.B.C.
.
N/A
STATIC MAXIMUM/MINIMUM VALUES:.NORTH-SOUTH: ( )
EAST-WEST: ( )
VMAX = S(0.2) W/(RdRo) = W * 0.22 = 1,200 KN2
3
VMIN = S(2.0)MV W/(RdRo) = W * 0.03 = 150 KN
DESIGN (D) LOADS
S.F. = g ٠Ie
RdRo= g 0.513٠
VDYINS = N/A
MDYINS = N/A
MPMR = N/A
VDNS = 1,200 KN
MDNS = 5,100 KN • m
VDYIEW = N/A
MDYIEW = N/A
MPMR = N/A
VDEW = 1,200 KN
MDEW = 5,100 KN • m
SEISMIC LOADS
NOTES:
(1) INITIAL DYNAMIC LOAD SCALING FACTOR
DYNAMIC ANALYSIS PROCEDURE LOADS ARE BASED ON THE EVALUATION OF THE BUILDING WITH THE INITIAL
SCALING FACTOR APPLIED. WHEN USED THESE ARE COMPARED TO THE STATIC FORCE VALUE IN ACCORDANCE
WITH 4.1.8.12(6)-(7) TO DETERMINE DESIGN LOAD VALUES.
(2) DESIGN LOAD SHEAR VALUES ARE BASED ON THE EVALUATION OF VES AND VDYI IN ACCORDANCE WITH 4.1.8.12
(5),(6) AND (7) OF THE 2012 OBC. LOADS INDICATED SHOW THE DESIGN BASE SHEAR AND CORRESPONDINGOVERTURNING MOMENT.
(3) N/A = NOT USED IN THE DESIGN OF THE BUILDING.
BUILDING WEIGHT FOR SEISMIC DESIGN:. W = 5,100 KN
(1)(3) (2)
2012 OBC CLAUSE 4.1.8.11(1)-(10) 2012 OBC CLAUSE 4.1.8.12(1)-(5)
VESEW = W * 0.22 = 1,200 KN
MESEW = 5,100 KN • m
NON-ORTHOGONAL EFFECTSHAVE BEEN CONSIDERED IN
ACCORDANCE WITH 2012 OBC
CLAUSE 4.1.8.8 (c)
YES
N/A
NORTH-SOUTH: ( ) NORTH-SOUTH: ( )
(INITIAL SCALING FACTOR)
NON-ORTHOGONAL EFFECTS
HAVE BEEN CONSIDERED INACCORDANCE WITH 2012 OBC
CLAUSE 4.1.8.8 (c)
YES
N/A
EAST-WEST: ( )EAST-WEST: ( )
WIND:
q= 0.41 KPa
(1 IN 50 YEARS)
= 1.0 (ULS) = 0.75 (SLS)
CpCg = 1.3 (1.95 AT ENDS)
NORTH-SOUTH: ( )
Vbase = 500 KN
Mbase = 5000 KN • m
EAST-WEST: ( )
Vbase = 800 KNMbase = 8000 KN • m
> 2 d
MIN. 800mm(32")
50mm(2")INTEGRITYBAR
HOOKATENDS
SLAB BOTTOM
BARS
S000
D
SCALE: N.T.S.
DETAIL: EXTERIOR SUPPORT
> 2 d
MIN. 800mm(32")50% BOTTOM
STEEL
50% BOTTOM
STEELINTEGRITY BAR
LAP INTEGRITY BARS WITHBOT SHORT BARS
S000
E
SCALE: N.T.S.
DETAIL: SUPPORT: DROP PANEL
> 2 d
MIN. 800mm(32")
BOTTOM
STEEL
INTEGRITY BAR
> 2 d
MIN. 800mm(32")
S000
F
SCALE: N.T.S.
DETAIL: SUPPORT: NO DROP PANEL
S000
B
SCALE: N.T.S.
DETAIL: ALTERNATE FROST PROTECTION
D03-1.2 MAIN BUILDING WIND:
D03-2.2 TEST FACILITY: WIND:
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS
N.T.S.S000
![Page 2: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/2.jpg)
12
BEND WALL BARS
INTO SLAB
1-10M
NOSING BAR
REFER TO PLANS FOR
WALL REINFORCING
COMPACTED SUBGRADE
1-15M TOP & BOTTOM
1
10M @
500mm(20")
2
400(16")
400(16")
D03-9 SLAB ON GRADE ELEVATION CHANGE U/N:
40
0(1
6")
MA
X
D03-10 SLAB ON GRADE AT DOORS:
600(24")
25
0(1
0")
MIN
FINISHED GRADE
COMPACTED
GRANULAR FILL
15M @ 300(12")o.c. EW
10M @ 300(12") E.W.
15M @ 200(8")
HOR. ADD'L IN
THICKENING
1
2
L51x51x6.4 (2"x2"x14") + STOP BAR
40mmx6.4mm (112"x
14") GALV. ANCHOR PLATE
@ 600mm(24") c/c
(OR AS NOTED)
600(24")
OR LESS
PIPING/TRENCHES
(SEE CIVIL/MECH)
25(1") HI-100
RIGID INSULATION
3-10M T&B (EXTEND
600(24") PAST EDGE)
12
NOTES:
1. WHERE BARS ARE EPOXY COATED INCREASE BAR LENGTHS BY 20%.
2. FOR TRANSFER BEAMS OR BEAMS GREATER THAN 900 DEEP, LOCATION AND DETAIL OF CONSTRUCTION JOINT TO BE APPROVED
BY ENGINEER. IT SHALL BE ASSUMED JOINTS ARE NOT PERMITTED FOR TENDERING PURPOSES.
3. CONCRETE SLABS SHALL BE CONCRETED IN SECTIONS NOT EXCEEDING 560m² (6000 ft²) IN AREA. EACH POUR SHALL BE BOUNDED
BY A VERTICAL BULKHEAD OR ABUTTING CONSTRUCTION. PROVIDE ADDITIONAL REINFORCING AS PER DETAILS ON TYPICAL
DETAILS DRAWING.
20x20(3 4"x3
4") REVEAL AT EXPOSEDCONCRETE.
FOR CONFIGURATION SEE
ARCHITECTURAL AND/OR
STRUCTURAL DRAWINGS.
REGULAR REINFORCING AS
INDICATED ON DRAWINGS
ADD 15M @ 450(18") TOP
CONSTRUCTION JOINT AT
THIRD OF SPAN UNLESS
APPROVED. ALL LOCATIONS TO
BE APPROVED BY ENGINEER IN
WRITING PRIOR TO
CONSTRUCTION
2nd POUR
38x89 (TAPERED) KEY FOR
SLABS UP TO 175(7") 38x140
(TAPERED) KEY FOR THICKER
SLABS.
600(24") 600(24")
D03-9 PITS/TRENCHES, PADS AND CURBS U/N:
600
CLASS `B'
TENSION LAP
≤ 1200(4'-0")
20
0(8
")
200(8")
600(24")
20
0(8
")
GRATING OR PLATE
AS SPECIFIED
D03-10 UNDERSLAB/UNDERGROUND PIPING TRENCHES
D03-11 EXTERIOR SLAB ON GRADE @ DOORS (WHERE EXTERIOR
CONC. PAD/WALKWAY INTERFACES WITH DOORWAY)
D03-12 CONSTRUCTION JOINTS
300(12")
MIN.
ENGINEERED FILL AS PER
GEOTECHNICAL ENGINEER'S
RECOMMENDATIONS
12
25mm(1")100mm(4")
MIN.
EXTERIOR
15M @ 250(10")
DWLS E.F.
2
1
THICKEN SLAB ON GRADE TO
MATCH SUSPENDED SLAB
3-15M BOT. CONT. IN
THICKENING
450(18")
S001
B
SCALE: N.T.S.
DETAIL: SLAB ON GRADE ELEVATION CHANGE U/N
S001
C
SCALE: N.T.S.
DETAIL: SLAB ON GRADE AT DOORS
G E
N E
R A
L
N O
T E
S
A N
D D
E T
A I L
S
S001
E
SCALE: N.T.S.
PIT: SHALLOW: < 400 (16")
S001
F
SCALE: N.T.S.
PIT: DEEP: < 1200 (4'-0")
15M @ 300(12") (MAX) ADD'L
BEND BACK UP INTO SLAB
1
2
200(8")
600(24")
GRATING AS PER ARCH/MECH
VA
RIE
SS
EE
PLA
N
(8"
MIN
.)
VA
RIE
S
PROVIDE CAST IN INSERTS TO SUIT (SEE
ALSO G/S001)(GALVANIZED)
15M @ 300(12") (MAX) ADD'L
ALL BARS TO BE EPOXY COATED
S001
D
SCALE: N.T.S.
SECTION: TRENCH DRAIN
S001
H
SCALE: N.T.S.
TYPICAL UNDERSLAB/UNDERGROUND PIPING TRENCHES
S001
I
SCALE: N.T.S.
EXTERIOR SLAB ON GRADE @ DOORS: SLAB ON GRADE
S001
J
SCALE: N.T.S.
EXTERIOR SLAB ON GRADE @ DOORS: SUSPENDED SLAB
NON FROST SUSCEPTIBLE
FILL (REFER TO GEOTECH
REPORT)
50(2") HI-60 RIGID INSULATION
(EXTEND 1800mm (6'-0") OUT FROM
FACE OF WALL (+E.S. OF
THICKENING)
S001
K
SCALE: N.T.S.
STRUCTURAL SLAB
50x100(2"x4") KEY
E.S.15M @ 450x1000(18"x40")
LONG TOP ADD'L
NOTES:
1. SLABS ON E.S. OF CLOSURE STRIPS TO BE CONCRETED FIRST.
2. ALL FORMS IN BAY CONTAINING CLOSURE STRIP SHALL REMAIN IN PLACE UNTIL THE CONCRETE IN THE CLOSURE STRIP
IS >10 DAYS OLD.
3. CLOSURE STRIP SHALL BE CONCRETED 28 DAYS (OR MORE) AFTER ADJACENT PORTIONS OF THE SLAB.
4. AFTER REMOVAL OF THE FORMS RESHORE THE ENTIRE BAY & KEEP SHORES IN PLACE UNTIL CONCRETE IN CLOSURE
STRIP IS 28 DAYS OLD. IF THE SLABS ARE TO BE SUBJECT TO CONSTRUCTION LOADS ADEQUATE SHORES SHALL BE
PROVIDED AND REMAIN IN POSITION FOR SUCH TIME AS THE LOADS ARE IMPOSED.
5. FORMS & SHORES UNDER CLOSURE STRIP TO STAY IN POSITION UNTIL CONCRETE IN THE STRIP IS 28 DAYS OLD.
6. REINFORCING SHOP DRAWINGS REQUIRED TO SHOW REINFORCING DETAILING/ADDITIONAL BARS AT STRIPS.
LAP BOTTOM BARS WITH
`CLASS B' TENSION LAP
1200(4'-0") MIN.
(INCREASE WIDTH TO SUIT TENSION LAP LENGTHS)
10
0(4
")
38x140(112"x51
2") KEY IN WALLS250(10") THICK OR MORE
38x89(112"x31
2") KEY IN 200(8")AND 150(6") WALLSEARTH
FIR
ST
PO
UR
PROVIDE 20x20(3 4"x34")
REVEAL AT EXPOSED
CONCRETE
ALL EXTERIOR
INTERIOR FACE
PROVIDE 20x20(3 4"x34") REVEAL
AT EXPOSED CONCRETE MAX.
DISTANCE BETWEEN JOINTS:
20m(60') U/N
ALL EXTERIOREARTH
THICKNESS OF
CONCRETE WALL
OR SLAB
CONSTRUCTION
JOINT (C.J.)
CONSTRUCTION JOINTS IN WALLS
75(3")
36 DIA. LAP
450(18") MIN.
75(3")
SE
CO
ND
PO
UR
36
DIA
. LA
P
45
0(1
8")
MIN
.
COORDINATE JOINT
LOCATION WITH
CONTROL JOINT
INTERIOR FACE
T
SECOND POUR FIRST POUR
T/4
T/3
40
(11
2")
T/4
T&G TYPE JOINT
TOOL EDGE TO MATCH
CONTROL JOINTS
FIRST SLAB
SLAB REINFORCING CONT.
(IF SPECIFIED)
TH
ICK
NE
SS
SL
AB
40
(11
2")
CL.
D03-13 CLOSURE STRIP (AS REQUIRED ON PLAN)
S001
L
TONGUE AND GROOVE JOINT
CONSTRUCTION JOINT IN SLAB ON GRADE
S001
M
SCALE: N.T.S.
CONSTRUCTION JOINT KEY DETAIL
S001
N
SCALE: N.T.S.
VERTICAL JOINT
S001
O
SCALE: N.T.S.
HORIZONTAL JOINT
S001
P
SCALE: N.T.S.
CLOSURE STRIP
300(12")
1200(4'-0")
10
0(4
")
2
20
0(8
")
17
5(9
")
75
(3") 1 3
50
(14
")
SLOPE PAD AS PER
LANDSCAPING
COMPACTED GRANULAR `A'
(PLACE IN MAX 200(8") LIFTS)
NOTE:
PROVIDE EXTERIOR PADS AS REQUIRED. REFER TO
ARCH/LANDSCAPE DWGS FOR LOCATIONS/DIMENSIONS.
PROPORTION NORMAL DENSITY CONCRETE IN ACCORDANCE WITH CAN/CSA-A23.1, TO GIVE THE FOLLOWING QUALITY FOR
ALL CONCRETE AS INDICATED.
28 DAY CLASS OF
LOCATION STRENGTH SLUMP EXPOSURE
SLAB ON GRADE (INTERIOR) 25 MPa 80mm(314")
SLAB ON GRADE (EXTERIOR) 32 MPa 80mm(314") C-2
FOUNDATIONS WALLS
(NOT IN SHEAR WALLS OR COLUMNS) 30 MPa 75mm(3") F-2
FOOTINGS REFER TO SCHEDULES 75mm(3")
SHEAR WALLS REFER TO SCHEDULES 75mm(3")
COLUMNS REFER TO SCHEDULES 75mm(3")
SUSPENDED SLABS REFER TO PLANS 75mm(3")
PAVEMENT & WALKS 32 MPa 75mm(3") C-2
RETAINING WALLS 35 MPa 75mm(3") C-1
EXTERIOR LANDSCAPE WALL ELEMENTS 35 MPa 75mm(3") C-1
*OBTAIN THESE SLUMPS WITH AID OF SPECIFIED WATER REDUCING AGENT.
*NOTE: ALL CONCRETE EXPOSED TO EXTERIOR CONDITIONS TO HAVE MINIMUM 6% AIR ENTRAINMENT.
READY-MIXED CONCRETE AND CONCRETE PROPORTIONS SHALL BE IN ACCORDANCE WITH CSA A23.1, CLAUSE 12 AND AS
FOLLOWS:
1. MINIMUM ALLOWABLE COMPRESSIVE STRENGTH SHALL BE 30 MPa(4400psi) AT 28 DAYS OF AGE, UNLESS OTHERWISE
NOTED OR SHOWN.
2. IF BLENDED NORMAL PORTLAND CEMENT/CEMENTITIOUS HYDRAULIC SLAG IS USED EXCEPT FOR FLOOR MIXES, SLAG
CONTENT SHALL NOT BE MORE THAN 25% OF TOTAL MASS OF CEMENT. TOTAL VOLUME OF CEMENT IN CONCRETE
FLOOR MIXES SHALL BE 100% NORMAL PORTLAND CEMENT.
3. PROVIDE CERTIFICATION THAT MIX PROPORTIONS SELECTED WILL PRODUCE CONCRETE OF SPECIFIED QUALITY AND
YIELD AND THAT STRENGTH WILL COMPLY WITH CAN/CSA-A23.1-M06.
4. USE OF CALCIUM CHLORIDE NOT PERMITTED.
5. DO NOT CHANGE CONCRETE MIX WITHOUT PRIOR APPROVAL OF CONSULTANT. SHOULD CHANGE IN MATERIAL SOURCE
BE PROPOSED, NEW MIX DESIGN TO BE APPROVED BY CONSULTANT.
D03-14 CONCRETE MIXES
D03-15 EXTERIOR EQUIPMENT PADS
400(16")
MIN.
400(16")
MIN.
10M @ 300(12") E.W.
1-15M TOP @
PERIMETER
2-15M BOTTOM
@ PERIMETER
50(2") HI-40
INSULATION
UNDISTURBEDMATERIAL
REGRADE TO PROVIDE
DRAINAGE AS PER
LANDSCAPING
S001
Q
SCALE: N.T.S.
EXTERIOR EQUIPMENT PADS
CR
AN
E O
PE
NIN
G
CRANE OPENING
S
2-20M TOP 2'-6" (750mm)
BEYOND OPENING MIN.
FILLER SLAB REINF.
MATCH REINFORCING NOTED
ON PLANS.
2-20M TOP 2'-6" (750mm)
BEYOND OPENING MIN.
1-15M T&B x 1500mm (5'-0")
TYP. AT EACH CORNER
TYP. SECTION ALL
AROUND
NOTES:
1. CUT BOTTOM REINF. STEEL RUNNING THROUGH CRANE OPENING.
2. PROVIDE ON EACH SIDE OF OPENING 12 OF AREA STEEL INTERRUPTED (CUT) BY THE CRANEOPENING 2-20M MIN. THESE BARS SHALL SPAN TO ADJACENT SUPPORTS.
FILLER SLAB SAME
THICKNESS AS
FLOOR SLAB
10M @ 300(12")
DOWELS
450(18")
ADDITIONAL REINFORCING
(SEE PLAN ABOVE)
NOTE: LOCATION OF CRANE
OPENING TO BE CO-ORDINATED
WITH STRUCTURAL CONSULTANT
BEFORE PROCEEDING.
CL
C L
50(2")
ROUGHEN EDGE 450(18")
D03-16 TYPICAL CRANE OPENING (U/N)
1-15M CONT.
t1 > t2
a ≤ t-50(2")
1-15M CONT. ADD'L
1-15M CONT.ADD'L
SPLICE WIDTH
t2
t1
t
t
CLASS `B'
TENSION LAP
≥ 600(24")
D03-17 CHANGE OF LEVEL IN REINFORCED SLAB (U/N)
50
(2")
MA
X.
SPLICE WIDTH
≤ 600(24")
CLASS `B'
TENSION LAP
≥ 600(24")
S001
R
SCALE: N.T.S.
PLAN
S001
S
SCALE: N.T.S.
DETAIL
S001
T
SCALE: N.T.S.
STEP WITH DIFFERENT SLAB THICKNESS
S001
U
SCALE: N.T.S.
STEP SMALLER THAN `t`
a ≤ t-50(2")
STEP GREATER THAN ' t '
1-20M CONT. ADD'L
1-20M CONT.
ADD'L
t
t
CLASS `B'
TENSION LAP
≥ 600(24")
CLASS `B'
TENSION LAP
≥ 600(24")
S001
V
SCALE: N.T.S.
STEP GREATER THAN `t`
1. CONDUIT SHALL BE PLACED IN THE MIDDLE THIRD OF THE SLAB OR WALL.
2. CONDUIT SHALL NOT BE TIED TO REBAR.
3. CONDUIT SHALL ALWAYS RUN PARALLEL OR PERPENDICULAR TO COLUMN LINES.
4. CROSSING OF CONDUIT SHALL BE DONE AT 90° ANGLES.
5. CONDUIT MAY NOT BE PLACED IN SLABS OR WALLS UNLESS APPROVED BY ENGINEER. CONTRACTOR TO
SUBMIT CONDUIT LAYOUT DRAWINGS A MINIMUM OF 4 WEEKS PRIOR TO CONCRETING.
6. CONDUIT NOT APPROVED BY ENGINEER SHALL BE REMOVED/RELOCATED AS DIRECTED BY ENGINEER AT THE
CONTRACTOR'S OWN EXPENSE.
1. CONDUIT PLACEMENT TO CONFORM TO CSA A23.1
2. CONDUIT AREA SHALL NOT EXCEED 1% OF THE GROSS AREA (bxh).
3. CONDUIT TO BE SECURED TO TIES. CONDUIT SHALL NOT BE TIED
TO VERTICAL REBAR.
4. CONDUIT MAY ONLY BE PLACED IN COLUMN AFTER RECEIVING
WRITTEN APPROVAL BY ENGINEER.
5. CONTRACTOR SHOULD ASSUME CONDUIT IS NOT PERMITTED TO
BE PLACED IN COLUMN FOR PRICING PURPOSES.
6. CONDUIT MAY NOT BE PLACED IN SLABS OR COLUMNS UNLESS APPROVED
BY ENGINEER. CONTRACTOR TO SUBMIT CONDUIT LAYOUT DRAWINGS A
MINIMUM OF 4 WEEKS PRIOR TO CONCRETING.
7. CONDUIT NOT APPROVED BY ENGINEER SHALL BE REMOVED/RELOCATED
AS DIRECTED BY ENGINEER AT THE CONTRACTOR'S OWN EXPENSE.
>
SLABS AND WALLS:
h
COLUMNS:
t
t/3
t/3
t/3
b
2-20M T&B
(USE 4-20 T&B FOR BEAMS
WITH DOUBLE STIRRUPS)
ADD 4 SETS OF ADDITIONAL
STIRRUPS (SAME AS BEAM STIRRUPS)BEAMS:
MIN.MIN. MIN.
SLEEVES ARE
200(8")Ø MAX.
900(36") 400(16") 900(36")
D03-18 EMBED CONDUIT AND PIPE
1. SLEEVES SHALL NOT BE PLACED IN BEAMS UNLESS ENGINEER IS NOTIFIED.
2. INCREASE BAR LENGTHS BY 20% FOR EPOXY REBAR.
3. INFORM ENGINEER IF ANY SLEEVES EXCEED 200mm(8")Ø.
4. ALL SLEEVES SHALL BE COORDINATED WITH SUB-CONTRACTORS AND BE INDICATED ON REBAR SHOP DRAWINGS.
5. SLEEVE MAY NOT BE PLACED IN SLABS OR WALLS UNLESS APPROVED BY ENGINEER. CONTRACTOR TO SUBMIT
SLEEVE LAYOUT DRAWINGS A MINIMUM OF 4 WEEKS PRIOR TO CONCRETING.
6. SLEEVE NOT APPROVED BY ENGINEER SHALL BE REMOVED/RELOCATED AS DIRECTED BY ENGINEER AT THE
CONTRACTOR'S OWN EXPENSE.
H ≥
60
0(2
4")
11
23
13 ≤
20
0(8
")M
AX
.
1/3
S001
W
SCALE: N.T.S.
DETAIL: BEAM SLEEVES
D03-20 TYPICAL DETAILS:
• DETAILS NOTED ARE TO BE READ IN CONJUNCTION WITH PLANS/SPECIFICATIONS.
• DETAILS ARE APPLICABLE UNLESS OTHERWISE SHOWN ON DRAWINGS.
S <
30 x
t (
MIN
)
<
460
0(1
5'-0")
t = THICKNESS OF
SLAB
SUBMIT SAWCUT LAYOUT
DRAWING PRIOR TO
CONCRETE PLACEMENT
DEPTH OF CUT
D = 0.25 t
AREA OF
EQUIPMENT
PAD
TRENCHES/
RECESSES/PITS
c/w: LOADFLEX
JOINT FILLER
PROVIDE SAWCUTSAT ALL
• COLUMN LINES
• WALL LINES
• MAXIMUM SPACING
• CORNERS
• MID BAY
>400(16")
>4
00
(16")
RACKING POSTS
• ADJUST SAWCUTS
TO ENSURE POSTS
DO NOT BEAR ON
SAWCUTS
SAWCUT
PATTERNS TO BE
COORDINATED
WITH ARCH
LAYOUTS WHERE
CONC. IS
EXPOSED
D03-21 SLAB EDGE DETAILS: PARAPERTS/GLAZING U/N ON PLANS/SECTIONS:
D03-22 SLAB EDGE DETAILS: GLAZING/BRICK:
SCALE: N.T.S.
DETAIL: TYPICAL SAWCUT PATTERNS
S001
Y
UNDISTURBED SOIL
(REFER TO GEOTECHNICALREPORT)
CONC. SLAB
ON GRADE
REFER TO TYPICAL PIT
DETAILS FOR TRIMMERS
PRE-ENGINEERED STEEL
GRATE/COVER (REFER TO MECH.)
15M @ 300(12")
V.E.F. +DOWELS
15M @ 400(16") H.E.F. HOOK
@ CORNERS (+2-15M H.E.F.ADD'L AT TOP)
PVC WATERSTOP
1500(5'-0")
(MAX.)
250 (10") 250 (10")
'D'
ENGINEERED FILL
15M @ 300(12") B.E.W.
S001
G
SCALE: N.T.S.
DETAIL: DEEP SUMP/MECH PITS (4'-0"≤D≤10'-0")
D03-19 SLEEVES THROUGH BEAMS
CLA
SS
'B' T
EN
SIO
N
LA
P ≥
60
0(2
4")
CLASS 'B' TENSION
LAP ≥ 600(24")
BASE ON LARGER OF
SLAB/WALL BARS
WHERE WALL CONTINUSE
PROVIDE OPTIONS#2 DWLS
REBAR INTO SLAB:
OPTION#1: BEND VERTS (E.F.) INTO
TOP OF SLAB
OPTION#2: PROVIDE MATCHING
DWLS TO VERTS WITH
TENSION LAPS.
MIN. 38x100 (2"x4") SHEAR KEY
- KEY TO BE ± 12 WIDTH OFWALL (ie: 200mm WALL -
100mm KEY)
INTERFACE TO BE
ROUGHENED TO MIN
6.4mm(14") AMPLITUDE
S001
X
SCALE: N.T.S.
DETAIL: WALL/SLAB INTERFACE (EXCEPT SHEARWALL)
(SEE S300 FOR SHEARWALL CONDITIONS)
D03-8 SLAB ON GRADE DETAILS:
t1
t1
t1
t1RECESSED GRATE
(BY OTHERS)
≤75mm(3")
1
2
S001
A
SCALE: N.T.S.
DETAIL: SLAB ON GRADE AT FLOOR GRATES
OPENING TO BE LOCATED
AT MID/MID OF BAY
60
0(2
4")
< D
< 1
20
0(4
8")
C150x12 CONT.
CONNECTION OF CHANNEL
TO ANGLE/PLATE TO
DEVELOP 15 KNm
1-15M (MIN. 900(36") LONG)
ADD'L AT PLATE/ANGLE BENDS
L 203x152x13 (8"x6"x12") LLH
x200(8") WIDE
C150x12 @ 1200(48")o.c. MAX.
(+ENDS/CORNERS)
2-40x10(112"x
38")
STRAP ANCHORS
250(10")
75(3")
PROVIDE ON ALL FLOORS
WHERE GLAZING/OPENING
HORIZONTAL WIDTH ≥ 3000(10'-0")
≥(8
")
S001
Z
SCALE: N.T.S.
DETAIL: PARAPETS/STRIP GLAZING @ CONCRETE EDGES
BRACING AS PER DETAIL Ca/S001
60
0(2
4")
< H
< 1
20
0(4
8")
1-15M x900(36") LONG
ADD'L AT EACH
ANCHOR BEND
300x200x12 (12"x8"x12")
STEEL PLATE
C150x12 CONT.
C150x12 @ 1200(48")o.c. MAX.
(+ENDS/CORNERS)
CONNECTION OF CHANNEL TO
ANGLE/PLATE TO DEVELOP 15 KNm
4-40x10(112"x
38")
STRAP
ANCHORS
200(8")
75(3")
SCALE: N.T.S.S001
Aa DETAIL: PARAPETS/STRIP GLAZING @ INTERIOR
OF CONCRETE SLABS
PROVIDE ON ALL FLOORS
WHERE GLAZING/OPENING
WIDTH ≥
≥2
00
(8")
BRACING AS PER
DETAIL Ca/S001
11
90
0(3
6")
MA
X.
90
0(3
6")
MA
X.300x200x12 (12"x8"x1
2")ANCHOR PLATE
c/w: 2-16mm(5 8")Ø HILTI HSL-3ANCHORS (100mm(4") EMBED.)
(BOLTS TO BE 200(8")o.c.)
CONNECTION OF CHANNEL TO
ANGLE/PLATE TO DEVELOP 15
KNm
C150x12 HANGERS @ 1200(48")o.c. (MAX.)
(+ ENDS/CORNERS)
C150x12 CONT. AT BOTTOM
GLAZING: (MAX. HEIGHT TO LOWER
SUPPORT
= 3000(10'-0")
L 127x127x9.5(5"x5"x38") (GALV.)
SHELF ANGLE (BRICK ONLY)
L 203x152x12 (8"x6"x12") (LLH)
SUPPORT ANGLE
2-40x10(112"x
38")
STRAP ANCHORS
250(10")
75(3")
CEILING LINE
(MAX. DEPTH)
L 152x102x9.5(6"x4"x38") x150(6") WIDE SPACER
• WELD TO C150/SHELF ANGLE (BRICK ONLY)
CLADDING (REFER TO ARCH.)
L 102x102x6.4 (4"x4"x14")
KICKERS Tu=Cu=20 KN
1-15M x900(36") LONG ADD'L
AT EACH ANCHOR BEND
(NOTE: SHELF ANGLES/SPACERS AT BRICK ONLY)
SCALE: N.T.S.S001
Ba DETAIL: CLADDING/STRIP GLAZING SUPPORTS: DOWNSTAND ONLY
AT SUSPENDED SLABS
PROVIDE ON ALL FLOORS
WHERE GLAZING/OPENING
WIDTH ≥ 3000(10'-0")
BRACING AS PER
DETAIL Ca/S001
UPSTAND FRAMING (SEESECTIONS)
3"x316" AT EVERY 4th PANEL
(±16'-0") + ENDS (PLACE ON
EXTERIOR FACE OF HANGERS)
Cu=Tu=25 KN
DOWNSTAND FRAMING (SEE
SECTIONS)
END
16'-0" MAX. SPACING
16'-0" MAX.
SPACING
16'-0" MAX. SPACING
END
16'-0" MAX.
SPACING
S001
Ca
SCALE: N.T.S.
DETAIL: TYPICAL PARAPET/SPANDREL FRAMING BRACING
11
90
0(3
6")
MA
X.
90
0(3
6")
MA
X.
300x200x12 (12"x8"x12")
ANCHOR PLATE
c/w: 2-16mm(5 8")Ø HILTI HSL-3ANCHORS (100mm(4") EMBED.)
(BOLTS TO BE 200(8")o.c.)
CONNECTION OF
CHANNEL TO
ANGLE/PLATE TO
DEVELOP 15 KNm
C150x12 HANGERS @ 200(48")o.c. (MAX.)
(+ ENDS/CORNERS)
C150x12 CONT. AT
BOTTOM
GLAZING: (MAX. HEIGHT
TO LOWER SUPPORT
= 3000mm(10'-0")
L 127x127x9.5(5"x5"x38") (GALV.)
SHELF ANGLE (BRICK ONLY)
200x200x12 (8"x8"x12") PLATE
c/w: 2-40x10(112"x
38") STRAP
ANCHORS250(10")
75(3")
CEILING LINE
(MAX. DEPTH)
L 152x102x9.5(6"x4"x38") x150(6") WIDE SPACER
• WELD TO C150/SHELF ANGLE (BRICK ONLY)
CLADDING (REFER TO ARCH.)
L 102x102x6.4 (4"x4"x14") KICKERS
Tu=Cu=20 KN
1-15M x900(36") LONG ADD'L
AT EACH ANCHOR BEND
SCALE: N.T.S.S001
Da DETAIL: CLADDING/STRIP GLAZING SUPPORTS: UP/DOWNSTAND
AT SUSPENDED SLABS
12
00
mm
(48")
(MA
X)
GLAZING: MAX. HEIGHT
TO UPPER SUPPORT =
3000mm(10'-0")C150x12 CONT. AT TOP
15
0(1
52)
PROVIDE ON ALL FLOORS
WHERE GLAZING/OPENING
WIDTH ≥
BRACING AS PER
DETAIL Ca/S001
15
0(1
52)
2-L 52x52x6.4 (2"x2"x14")
x200/150 (8"/6") WIDE
ADJUSTABLE SPACERS
1-15M (MIN. 900(36") LONG)
ADD'L AT EACH BEND
CONT.
200x200x12 (8"x8"x12") PLATE
c/w: 2-40x10(112"x
38") STRAP
ANCHORS 250(10")
75(3")
L 127x127x9.5
(5"x5"x38") GALV.
SHELF ANGLE
BRICK CLADDING
ALIGN WITH SHELF
ANGLES AT ALL
FLOORS
S001
Ea
SCALE: N.T.S.
DETAIL: CLADDING SUPPORTS AT CONC. COL'S/WALLS
(PROVIDE ON ALL FLOORS ABOVE EL=±11m (33'))
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS
N.T.S.S001
![Page 3: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/3.jpg)
S002
A
SCALE: N.T.S.
TYPICAL COLUMN STRIP/MIDDLE STRIP LAYOUT
6.4x150mm(14"x6") WIDEPLATE @ 1200(48") o.c.
NON-LOADBEARING
SMR @ 400(16") 1-10M @
1200(48")
HDMR @ 600(24") 1-15M @
1200(48")
HDMR @ 400(16") 1-15M @
800(32")
HDMR @ 400(16") 1-20M @
800(32")
LOAD BEARING
HORIZ. SMR @ 200(8") OR
HDMR @ 400(16") VERT. 1-15M
@ 800(32")
HORIZ. HDMR @ 200(8") VERT.
1-20M @ 600(24")
HORIZ. HDMR @ 200(8") VERT.
1-20M @ 400(16")
HORIZ. HDMR @ 200(8") &
400(16") (ALTERNATE) VERT.
1-20M @ 1200(48")
1. ALL MASONRY WORK SHALL COMPLY WITH CAN3-S304.1-06, CAN3-A370-M84 AND A371-M84 UNLESS OTHERWISE
NOTED.
2. MINIMUM MASONRY REINFORCEMENT (UNLESS OTHERWISE NOTED):
3. VERTICAL BARS SHALL BE CONTINUOUS, LAPPED ONLY AT FLOORS, DOWELED INTO SUPPORTS AND GROUTED INTO CLEAR
VERTICAL BLOCK CORES SEALED ALL AROUND WITH MORTAR, PROVIDE CLEAN-OUT PORT AT BOTTOM OF EACH GROUTED
CORE. DO NOT CLOSE PORT OR PLACE GROUT UNTIL CORE AND STEEL HAVE BEEN INSPECTED. PROVIDE THREE GROUTED
REINFORCED (20M) CORES AT EACH CORNER AND INTERSECTION (MIN.).
4. PROVIDE 1-20M IN 2-COURSE DEEP FULLY GROUTED HORIZONTAL BOND BEAM AT THE TOP OF ALL LOAD BEARING WALLS U/N.
5. PROVIDE APPROVED LATERAL SUPPORT TO TOP AND BOTTOM OF MASONRY PANELS AT GROUTED CORE LOCATIONS OR AT
1800mm(6'-0") MAXIMUM SPACING WHERE NO VERTICAL REINFORCEMENT IS REQUIRED; ALSO AT SIDES OF MASONRY PANELS
AT 4 TIMES THE WALL THICKNESS.
6. COMPRESSIVE STRENGTH OF MATERIALS USED FOR LOAD BEARING AND PANEL WALLS SHALL BE IN EXCESS OF THE
FOLLOWING VALUES:
a) MASONRY UNITS - HOLLOW CONCRETE BLOCK 15 MPa (2200 psi)
- SOLID CONCRETE BLOCK (GROSS AREA) 15 MPa (2200 psi)
7. TYPE `S' MORTAR SHALL BE USED FOR MASONRY BELOW GRADE, MIN. STRENGTH fm = 12.4 MPa. (1800 psi) TYPE `N' MORTAR
SHALL BE USED ABOVE GRADE, MIN. STRENGTH fm = 5.2 MPa. (800 psi)
8. GROUT TO BE A MINIMUM OF 15 MPa (2900 psi) MIN. SLUMP OF 200mm (8").
9. MORTAR FOR EXPOSED MASONRY SHALL BE AIR ENTRAINED.
10. PROVIDE LINTELS FOR ALL OPENINGS AND/OR RECESSES IN MASONRY WALLS SHOWN ON THE ARCHITECTURAL OR
STRUCTURAL DRAWINGS INCLUDING THOSE FOR MECHANICAL OR ELECTRICAL SERVICES OR EQUIPMENT.
(SEE LINTEL SCHEDULE)
11. INTERSECTING OR ABUTTING WALLS SHALL BE BONDED ADEQUATELY TOGETHER.
12. PROVIDE MINIMUM 25mm(1") GROUT UNDER ALL WALL PLATES AND BASE PLATES.
D04) MASONRY
WALL
THICKNESS
140mm (6")
190mm (8")
240mm (10")
290mm (12")
D04-1 GENERAL:
D04-2 NON-LOADBEARING MASONRY WALL @ STEEL JOIST:
25mm (1") MIN.
COMPRESSIBLE MATERIALSTEEL DECK
25mm (1") MIN.
COMPRESSIBLE
MATERIAL AT ANGLE
LOCATION
L 76x76x6.4(L3"x3"x14") @
1200(4'-0") o.c. MAX.
MASONRY WALL
L76x76x6.4x150LG (L3"x3"x14"x6"LG) AT
L76x76x6.4(L3"x3"x14") LOCATION
FILL VOIDS UNDER
DECK
STEEL DECK
25mm (1") MIN.
COMPRESSIBLE MATERIAL
25mm (1") MIN.
COMPRESSIBLE MATERIAL
AT ANGLE LOCATION
MASONRY WALL
L76x76x6.4x150LG (L3"x3"x14"x6"LG) AT
L76x76x6.4(L3"x3"x14") LOCATIONSTEEL JOIST
STEEL JOIST
D04-3 NON-LOADBEARING MASONRY WALL @ CONCRETE SLAB:
CONCRETE SLAB
1-16mmØ(5 8"Ø) SELF DRILLINGCONCRETE HILTI KWIK BOLT III
ANCHOR (E/S)
L 127x76x6.4(L5"x3"x14") LLV x150(6")
LG. @ 1200 (48") c/c EA. SIDE (@
GROUTED CORES)
GAP OR COMPRESSIVE
MATERIAL BETWEEN SLAB
AND TOP OF WALL. SEE
MASONRY SPECIFICATIONS
10
0(4
")
1-16mmØ(5 8"Ø) SELF DRILLINGCONCRETE HILTI KWIK BOLT III
ANCHOR (E/S)
L 127x76x6.4(L5"x3"x14") LLV x150(6")
LG. @ 1200 (48") c/c EA. SIDE (@
GROUTED CORES)
GAP OR COMPRESSIVE
MATERIAL BETWEEN SLAB
AND TOP OF WALL. SEE
MASONRY SPECIFICATIONS
CONCRETE SLAB100(4")
10
0(4
")
10
0(4
")
G E
N E
R A
L
N O
T E
S
A N
D D
E T
A I L
S
400(32")
3-15M BOT. LONG.
10
0(4
")
ADD LAYER OF MESH
900mm(36") WIDE FOR FULL
LENGTH OF WALL
25
0(1
0")
D04-5 NON-LOADBEARING MASONRY WALL @ SLAB-ON-GRADE: H ≤ 5m(16'-0")
FOR BLOCK THICKNESS
AND LOCATIONS SEE
ARCH. FLOOR PLAN
600mm(24") LONG DOWELS TO
MATCH VERT. REINFORCING (DRILL
& GROUT 4")
ENGINEERED FILL
qSLS ≥ 100 KPa(2100psf)
600(24")
3-15M BOT. LONG.
ROUGHEN/CLEAN/WET
SURFACE PRIOR TO CONC
PLACEMENT
FOR BLOCK THICKNESS
AND LOCATIONS SEE
ARCH. FLOOR PLAN
600mm(24") LONG DOWELS TO
MATCH VERT. REINFORCING (DRILL
& GROUT 4")
ENGINEERED FILL
qSLS ≥ 100 KPa(2100psf)
50(2")MAX 100(4")MIN
25 MPa(3625psi) CONC
EXIST CONC SLAB
2-10M DOWELS @ 600(24")o.c.
(x400(16) LONG)
HILTI HIT HY-200 ADHESIVE
S002
C
SCALE: N.T.S.
WALL PARALLEL TO JOIST/BEAM
S002
D
SCALE: N.T.S.
WALL PERPENDICULAR TO JOIST/BEAM
S002
E
SCALE: N.T.S.
INTERIOR
S002
F
SCALE: N.T.S.
EXTERIOR
S002
G
SCALE: N.T.S.
NEW WALL/SLAB
S002
H
SCALE: N.T.S.
NEW WALL/EXISTING SLAB
OPENINGS > 1500(60")
< 2500(100")
40
0(1
6")
20
0(8
")
20MPa CONC.
2-10M B
OPENINGS < 1500(60")
40
0(1
6")
OPENINGS >2500(100")
2-15M T&B
20MPa CONC.
20MPa CONC.
2-20M BOT.
10M @ 200(8")
2-15M TOP
<4000(160")
D04-6 MASONRY LINTELS FOR NON-LOADBEARING WALLS:
PROVIDE 200(8") MINIMUM BEARING AT SUPPORTS
LOOSE LINTEL SCHEDULE
SPANS < 1200(48") L 90x90x6.4 (L312"x31
2"x1
4")
SPANS < 1800(72") L 102x90x7.9 (L4"x312"x
516")
SPANS < 2400(96") L 127x90x7.9 (L5"x312"x
516")
SPANS < 3000(120") L 152x102x10 (L6"x4"x38")
PROVIDE LOOSE LINTELS ABOVE ALL MASONRY CLADDING OPENINGS U/N.
ALL LOOSE LINTELS TO BE HOT DIPPED GALVANIZED AT EXTERIOR CONDITIONS U/N.
PROVIDE MIN. 150(6") BEARING EACH END.
LOOSE LINTEL SCHEDULE: NLB BLOCK WALLS (EXISTING)
SPAN 140(6") 190(8")
< 1200(48") 2-L 89x64x6.4 (2-L312"x21
2"x1
4") 2-L 89x89x6.4 (2-L312"x31
2"x1
4")
< 1800(72") L 127x127x7.9 (L5"x5"x516") 2-L 102x89x7.9 (L4"x31
2"x5
16")
< 2400(96") L 152x152x9.5 (L6"x6"x38") 2-L 127x89x9.5 (L5"x31
2"x3
8")
< 3000(120") N/A 2-L 152x89x9.5 (L6"x312"x3
8")
D04-7 LOOSE LINTEL SCHEDULE - 90mm(312") BRICK MASONRY:
GROUT BOTTOM
COURSE SOLID
L 6"x6"x 516" x WIDTH OF BLOCK AT 3rdCOURSE
WELD PLATE
LINTEL AS PER SCHEDULE
SCALE: N.T.S.
DETAIL: MASONRY SUPPORT AT CONCRETE COLUMN/WALL
S002
I
L 6"x6"x 516" x WIDTH OF BLOCK AT 3rdCOURSE
SCALE: N.T.S.
DETAIL: MASONRY SUPPORT AT STEEL COLUMN
S002
J
WELD ANGLE TO COLUMN
LINTEL AS PER SCHEDULE
SCALE: N.T.S.
DETAIL: MASONRY TIES AT STEEL COLUMN
S002
K
6mm(14")
6mm(14")
GROUT CORES SOLID THAT HOUSE
STRAP LEG.
10mm(3 8") THICKx40(112") WIDE
STRAP ANCHORS c/w ZINC RICH
PAINT @ 600mm (24") o.c.
STEEL COLUMN (SEE PLANS)
SCALE: N.T.S.
DETAIL: MASONRY TIES AT CONC COLUMN/WALL
S002
L
6mm(14")
6mm(14")
GROUT CORES SOLID THAT HOUSE
STRAP LEG.
10mm(3 8") THICKx40(112") WIDE
STRAP ANCHORS c/w ZINC RICH
PAINT @ 600mm (24") o.c.
CONC COLUMN (SEE PLANS)
STEEL TIES IN CONC COLUMN
400(16")
50(2
")
50(2
")
250mm(10")x6.4mm(14") CAST-IN PLATE AT OFMASONRY WALL IN COLUMN
c/w: 12mm(12")Ø NELSON STUDS @ 400(16")o.c. x200(8")LONG
64mm(212")x6.4mm(14") CAST-IN PLATE AT OF
MASONRY WALL IN COLUMN/WALL
c/w: 10mm(3 8")Ø NELSON STUDS @ 600(24")o.c.x200(8") LONG
SCALE: N.T.S.
DETAIL: BLOCK AT U/S OF BEAM
S002
M
LATERAL SUPPORTS
L 125x75x6.4(5"x3"x14") x150mm(6")
LONG @ S SPACING (STAGGERED)
25mm(1") COMPRESSIBLE
MATERIAL
L 65x65x6.4(212"x21
2"x14") BRACES
@ S SPACING
• TO ADJACENT MEMBERS
• Cu=Tu=15kN
S < 800mm(2'-8"): 90(4") BLOCK
S < 1200mm(4'-0"): 140(6") BLOCK
S < 1500mm(5'-0"): 190(8") BLOCK ORLARGER
D04.7 MASONRY SUPPORT AT COLUMNS
400(16")
50(2
")
50(2
")
GRID
GRID
GRID
GRIDGRIDGRID
C1 M1 C1 U/N M1 U/N C1 U/N
CA
MA
CA
U/N
MA
U/N
CA
U/N
21
WC
SW
CS
50% TOP (LONG) (TYP.)
50% TOP (SHORT) (TYP.)
50% BOT. (TYP.)
50% BOT. (TYP.)
50% TOP (LONG) (TYP.)
50% TOP (SHORT) (TYP.)
100% TOP (LONG) 100% TOP LONG
CLASS B
TENSION LAP
BOT.BOT.
TOP
U/N PROVIDE MATCHING STRIP STEELUNLESS NOTED OTHERWISE (TYP.)
LAP BOT. BARS ON OFFSET LINE
(TYP. ALL STRIPS WHERE
COLUMNS ARE OFFSET)
CENTRE TOP BARS ON OFFSET
LINE (TYP. ALL STRIPS WHERECOLUMNS ARE OFFSET)
SEE NOTE BELOW
SLAB EDGEFLARE:• tF = DEPTH/EXTENSION OF FLARE• tF = ≥ tS
2
• tF = ≥ 150mm (6")• ALL FLARES TO BE ON 45° ANGLES
INTEGRITY STEEL:• REFER TO PLANS FOR
QUANTITIES (SEE ALSO MIN.BELOW)
• REFER TO INTEGRITY STEEL
NOTES ON S000 SERIES FORLENGTHS/LAPS
• REQUIRED @ ALL COLUMNS
DROP PANEL:• tD ≥ 100mm (4")
• tD ≥ tS 2
ALTERNATE BARS (TYP.)
RD.
100
% T
OP
CO
NT
.
50%
TO
P (
SH
OR
T)
50%
TO
P (
LO
NG
)
50%
BO
T.
50%
BO
T.
100
% B
OT
@ C
AN
T.
50%
BO
T.
50%
BO
T.
100
% B
OT
@ C
AN
T.
100
% T
OP
BA
RS
@ C
AN
T.
54
3
ALTERNATE BARS (TYP.)
≥ 24 db U/N≥ 300mm (12") U/N
FOR BAYS CONTAINING SLOPES. (ie. SLOPE TO DRAINS)• SOFFIT OF SLAB TO REMAIN FLAT/CONSTANT U/N.
• VARY THE TOP OF THE SLAB TO SUIT DRAINAGE LINES(MAX. 150mm (6") SLOPE)
• USE VARYING HEIGHT CHAIRS TO TOP STEEL TO MAINTAIN
CONSTANT CONCRETE COVER SPECIFIED
WHERE SLAB BANDS OCCUR
LOWER PARALLEL BOTTOMSTEEL TO MAINTAIN SPECIFIED
CONCRETE COVER (TYP.)
HOOK ALL BOTTOM STEEL @
CANTILEVER ENDS (TYP.)- EXTEND BACKSPAN BARS FULL
LENGTH (NO BOT. SHORT
BARS)
CONCRETE SLAB:
• tS ≥ 150mm (6")
AT EXTERIOR EDGES EXTEND
TOP/BOT. BARS TO WITHIN 50mm(2") FROM EDGE (TYP.)
≥ 2
4
CLASS B
TENSION LAP
CLASS B
TENSION LAP
Wd
SLAB BAND
.
75
mm
(3
") M
IN.
D03-23: CONCRETE SLAB/REBAR NOTES
2-15M CONT. @
PERIMETER (TYP.)
TOP (END BAY)
WCS WCS
OF
FS
ET
LIN
E
TB
S
TB
L
TB
L
TO
P (
EN
D B
AY
)
TB
C
IF BOT. BARS ARE NOT CONT. TO
EDGE, LAP CANT. BARS WITHINTERIOR BAY BARS (CLASS 'B'
TENSIONS LAP) BOTH M.S./C.S.
PROVIDE ADD'L BARS FOR
AROUND SHOWER AS PER
G/H S002 AT ALL LOCATIONS
(TYP) E.S.
DRAIN (SEE PLANS)
25mm(1") MAX
USE VARYING HEIGHT CHAIRS
TO MAINTAIN COVER TO
REINFORCING STEEL
MAINTAIN STEEL AS PER PLANS
S002
B
SCALE: N.T.S.
DETAIL: RECESS IN BATHROOM AREAS
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTUREPERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURETENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS
N.T.S.S002
![Page 4: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/4.jpg)
G E
N E
R A
L
N O
T E
S
A N
D D
E T
A I L
SAPPLICABLE SPECIFICATION (UNLESS OTHERWISE NOTED)
G40.21M - 350W
G40.21M - 350W (CLASS C)
A325 (BEARING TYPE)
A307 (UNLESS OTHERWISE NOTED IN BASEPLATE SCHEDULE)
G40.21M-300W
ITEM
ROLLED SECTIONS
HSS (TUBE) SECTIONS CONNECTION
BOLTS
ANCHOR BOLTS
BRACE FRAME/BEARING PLATES
STRUCTURAL STEEL SHALL COMPLY WITH CAN3-S16.1-01(06) UNLESS OTHERWISE NOTED.
1. ALL STEEL WORK SHALL BE GIVEN ONE COAT OF APPROVED PRIMER.
2. FIELD AND SHOP CONNECTIONS SHALL BE WELDED OR HIGH TENSILE BOLTED (ASTM STANDARD A325).
3. WELDING SHALL CONFORM TO LATEST CSA SPECIFICATION W59 AND BE UNDERTAKEN BY A FABRICATOR
APPROVED BY THE CANADIAN WELDING BUREAU TO THE REQUIREMENTS OF CSA SPECIFICATION W47.1.
4. ALL EXPOSED WELDS SHALL BE CONTINUOUS AND BE GROUND SMOOTH.
5. ALL EXTERIOR EXPOSED STRUCTURAL STEEL SHALL BE GALVANIZED OR PAINTED WITH APPROVED RUST
INHIBITIVE PAINT.
6. STRUCTURAL STEEL MEMBERS SHALL NOT BE SPLICED UNLESS APPROVED BY THE STRUCTURAL ENGINEER IN
WRITING.
7. WHERE STRUCTURAL STEEL MEMBERS SPECIFIED ON THE STRUCTURAL DRAWINGS ARE UNAVAILABLE TO THE
CONTRACTOR, THE STRUCTURAL STEEL CONTRACTOR SHALL PROVIDE MEMBERS HAVING ALL SECTION
PROPERTIES EQUAL TO OR BETTER THAN THAT OF THE SPECIFIED MEMBERS AT NO ADDITIONAL COST. CONTACT
ENGINEER FOR ACCEPTANCE OF ANY AND ALL SUBSTITUTIONS.
1. ALL METAL DECK SHALL BE A MINIMUM OF 38mm(1 12") DEEP, WITH DECK FLUTES AT 150mm(6") CENTRES,CONTINUOUS OVER AT LEAST THREE SPANS, AND SHALL BE FORMED FROM SHEET STEEL CONFORMING TO CSSBI
10M/12M/20M, MINIMUM GRADE `A', WITH A BASE STEEL NOMINAL THICKNESS SPECIFIED ON PLANS, AND A MINIMUM
ZINC COATING DESIGNATION OF "WIPED COAT".
MINIMUM SIZES AS FOLLOWS (U/N ON PLANS):
ROOFS: 38x1.22 (1 12"x18 ga)
FLOORS: 38x1.22 (1 12"x18 ga) COMPOSITE
2. DECK CONNECTIONS TO SUPPORTING STRUCTURE TO BE AS FOLLOWS (U/N ON PLANS):
20mm(3 4")Ø FUSION WELDS @ 914/7
20mm(3 4")Ø FUSION WELDS @ 300mm(12") TRANS
20mm(3 4")Ø FUSION WELDS @ 300mm(12") PERIMETER. SIDE LAP: BUTTON PUNCH @ 300mm(12") o.c.
3. ALL WELDS SHALL BE PRIME PAINTED BY DECK CONTRACTOR.
4. STEEL DECK CONTRACTOR TO REINFORCE ALL OPENINGS IN DECK 18" IN SIZE OR SMALLER.
5. ALL DECK CLOSURES SHALL BE SUPPLIED AND INSTALLED BY THE DECK CONTRACTOR. (PROVIDE DECK CLOSURES
AT ALL AREAS WHERE DECK EDGES ARE WEAK).
6. WEDGE THE FLUTES OF THE STEEL ROOF DECK UNDER WOOD SLEEPERS CARRYING ROOF TOP UNITS (THIS SHALL
ALSO APPLY TO ROOF TOP UNITS WITH METAL CURBS).
7. NO MECHANICAL OR ELECTRICAL EQUIPMENT/ACCESSORIES SHALL BE HUNG FROM THE STEEL DECK.
8. HANGERS FOR SUSPENSION OF CEILING ARE TO BE ATTACHED TO THE STEEL JOISTS. THESE MAY HOWEVER BE
ATTACHED IN BETWEEN STEEL JOISTS TO THE SIDE OF THE DECK FLUTES AND BY LOOPING AND TYING AROUND,
BUT ON NO ACCOUNT SHOULD THESE HANGERS BE PUNCHED THROUGH THE BOTTOM FLUTES.
D05) STEEL
D05-1 STRUCTURAL STEEL:
D05-2 STEEL DECK:
STEEL DECK
JOISTS
SUPPORT BY OTHERS
MECH. PIPE
SCALE: N.T.S.
EQUIPMENT SUPPORTS
S003
A
• ALL EQUIPMENT SUPPORTS ARE THE
RESPONSIBILITY OF THE CONTRACTOR
UNLESS NOTED ON STRUCTURAL DRAWINGS
• SUPPORTS ARE TO BE PROVIDED AT TIME OF
STEEL SHOP DRAWING SUBMISSION AND
COORDINATED WITH STEEL ENGINEER'S
DRAWINGS/DETAILS
• SUPPORT LAYOUTS THAT AFFECT BASE
BUILDING ELEMENTS AND RESULT IN
CHANGES WILL BE DONE AT NO COST TO THE
CONTRACT.
1. ALL JOISTS ARE TO BE EQUALLY SPACED BETWEEN TIE JOISTS/BEAMS.
2. ALL JOISTS ARE TO BE CAMBERED FOR FULL DEAD LOAD DEFLECTION. LIMIT LIVE LOAD DEFLECTIONS TO NOT MORE
THAN L/360 FOR ROOF AREAS AND NOT MORE THAN L/480 FOR FLOOR AREAS. TOTAL LOAD DEFLECTION FOR FLOOR
JOISTS NOT TO EXCEED L/240. FLOOR JOISTS TO ALSO MEET VIBRATION CRITERIA OUTLINED IN 2012 OBC CLAUSE 4.1.3.6.
3. IN ORDER TO FACILITATE THE PASSAGE OF MECHANICAL DUCTS AND PIPES THROUGH THE ROOF JOISTS, THE JOIST
SUPPLIER SHALL LOCATE THE DIAGONALS SO THAT THEY LINE UP FROM JOIST TO JOIST.
4. SPECIFIED POINT LOADS ARE SHOWN ON PLANS.
5. ALL PIPES MUST BE HUNG FROM TOP CHORD OF JOISTS. IF A LOAD (APPROVED BY THE STRUCTURAL ENGINEER) IS
HUNG FROM A JOIST AT A LOCATION OTHER THAN THE PANEL POINT, THEN A WEB DIAGONAL SHALL BE WELDED FROM
THE HANGER LOCATION TO THE NEAREST PANEL POINT ON THE OPPOSITE CHORD.
6. LOADING DIAGRAMS:
AREAS SHADED ON ROOF PLAN INDICATE EXTENT OF ADDITIONAL SNOW PILING WITH PEAK (SPECIFIED) LOADS NOTED.
ROOF DECK AND JOISTS SHALL BE DESIGNED, MANUFACTURED AND ERECTED TO SUPPORT BASIC SPECIFIED AS WELL
AS ADDITIONAL SNOW LOADING.
7. a) PROVIDE 1 ROW OF HORIZONTAL BRIDGING AT FIRST BOTTOM CHORD PANEL POINT AT EACH END OF JOIST. PROVIDE
ADDITIONAL CROSS BRIDGING AS INDICATED ON PLAN.
b) STEEL CONTRACTOR SHALL DESIGN, SUPPLY AND ERECT REMAINDER OF HORIZONTAL JOIST BRIDGING OF
SUFFICIENT SIZE AND SPACING IN ACCORDANCE WITH CSA S16.1 LATEST EDITION.
8. DESIGN JOISTS FOR ALL LOADING CONDITIONS SPECIFIED IN THE NATIONAL BUILDING CODE IN ADDITION TO THE SNOW
LOADS SPECIFIED ON PLANS.
9. PROVIDE ADDITIONAL X-BRIDGING BETWEEN THE OUTSIDE PERIMETER BEAMS AND THE FIRST ROW OF JOIST RUNNING
PARALLEL. ADDITIONAL BRIDGING IS SHOWN AS ON PLAN. MINIMUM SIZE TO BE L 38x38x4 (L 112"x11
2"x18")
SPACED @ 1800(6'-8") c/c (MAX.) UNLESS OTHERWISE NOTED.
JOIST BRIDGING
TO BE CUT
MECHANICAL
DUCT
L 65x65x6 MIN. (L 212"x21
2"x316" MIN.) ADDED
X-BRIDGING IN EACH BAY ADJACENT TO CUT
BRIDGING ON EACH BRIDGING LINE
TYPICAL DETAIL WHERE BOTTOM CHORD JOIST BRIDGING AND/OR BRACING
D05-3 STEEL JOISTS AND BRIDGING: S16.1 AND S136:
SCALE: N.T.S.
IS REQUIRED TO BE CUT DUE TO INTERFERENCE BY MECHANICAL DUCTWORK
S003
B
OWSJ OR STEEL BEAMS
(SEE PLAN)
IF THIS DIMENSION EXCEEDS
2000mm (6'-8") CONSULTSTRUCTURAL CONSULTANT
BEFORE PROCEEDING
FOR JOIST SPACINGUP TO 2000mm (6'-8"): C130x10 (C5x6.7)
FOR LARGER SPACING: SEE PLAN
FOR OPENING LENGTHS
UP TO 900mm (3'-0"): L65x65x5 (L212"x21
2"x3
16")FROM 900mm (3'-0") TO 1800mm (6'-0"): C130x10 (C5x6.7)
OP
EN
NOTES:
1. TOP OF ALL TRIMMING STEEL AT UNDERSIDE OF STEEL DECK UNLESS OTHERWISE NOTED.
2. LOCATION OF ALL MECHANICAL UNITS AND OPENINGS THROUGH ROOF IS BASED ON INFORMATION SHOWN ON MECHANICAL
DRAWINGS. THE STRUCTURAL STEEL SUB-CONTRACTOR MUST CONFIRM ALL THESE DIMENSIONS AND SIZES WITH THEMECHANICAL CONTRACTOR.
3. OWSJ MUST BE DESIGNED FOR ADDITIONAL LOADS FROM MECHANICAL UNITS.
4. IF ACTUAL LOCATIONS OR DETAILS VARY FROM THOSE SHOWN, THE STRUCTURAL CONSULTANT MUST BE INFORMED ANDINSTRUCTIONS RECEIVED BEFORE PROCEEDING WITH THE WORK.
5. THE STRUCTURAL STEEL SUB-CONTRACTOR IS TO SUBMIT ERECTION DRAWINGS TO THE MECHANICAL ENGINEER AND/ORCONTRACTOR FOR APPROVAL OF SIZE AND LOCATION OF OPENINGS FOR MECHANICAL UNITS.
D05-5 TYPICAL DETAILS FOR TRIMMING TO OPENINGS THROUGH STEEL ROOF DECK:
SCALE: N.T.S.
DETAIL: ROOF ANCHOR SUPPORTS
S003
C
L 76x76x6.4(3"x3"x14") BRACES TO
ADJACENT MEMBERSPF = 25KN (±)
STEEL BEAM
OR JOIST
ASSEMBLY BY OTHERS
• ALL ANCHORS TO BE ALIGNED ON BEAMS OR JOISTS
• SHOP DRAWINGS FOR ANCHORS INCLUDING ALL LOADING TO BE INCLUDED WITHSTRUCTURAL STEEL SHOP DRAWINGS
PARAPET/STRIP WINDOW FRAMING AS REQ'D600(24")<H<1200(48"):
C150x12 @ 1200(48")o.c. (ALIGN WITH JOISTS)
c/w: CONTINUOUS C150x12 AT TOP(NOTE: PROVIDE FRAMING FOR ALL STRIP
GLAZING SITUATIONS WHERE H≤1200(48")EDGE ANGLE(SEE PLANS)
DECK AS PER
PLANS
CLADDING/BACK-UP WALL
(REFER TO ARCH.)
L 76x76x6.4(3"x3"x14")
KICKERS Cu=Tu=15KN U/N• PROVIDE TO 1st PANEL
POINT OF ALL JOISTS
(MAX. 60° ANGLE FROMHORIZONTAL)
BEAM (AS PER PLANS)
EXTEND JOISTSHOES TO SUIT
SCALE: N.T.S.
DETAIL: JOIST AT EDGE (TYP)
S003
D
DESIGN JOIST SHOE FOR
ROLLOVER FORCES (SEENOTES/PLANS)
DECK AS PERPLANS
CLADDING/BACK-UP WALL
(REFER TO ARCH.)
L 76x76x6.4(3"x3"x14")
KICKERS Cu=Tu=15KN U/N
• PROVIDE AT 14 POINTS OF BEAM(MAX 3m(10'-0")o.c.)
• MAX. 60° ANGLE FROM HOR.)
BEAM (AS PER PLANS)
>D
SCALE: N.T.S.
DETAIL: BEAM AT EDGE (TYP)
S003
E
PARAPET/STRIP WINDOW FRAMING AS REQ'D600(24")<H<1200(48")
C150x12 @ 1200(48")o.c.
c/w: CONTINUOUS C150x12 AT TOP(NOTE: PROVIDE FRAMING FOR ALL STRIP
GLAZING SITUATIONS O<H<1200(48"))
EDGE ANGLE (SEE PLANS)
WHERE:• D<100mm(4") NO CHANNEL STUB
• 100mm(4") < D < 300(12")
C100x9 @ 1200(48")o.c.• 300(12") < D < 600(24")
C200x17 @ 1200(48")o.c.
DECK AS PER PLANS
SCALE: N.T.S.
DETAIL: TYPICAL SHEAR TAB
S003
F
JOISTS (AS PER PLANS)CONNECTION OF HSS TO BEAM TO
MATCH DECK CAPACITY AT LINE BASEDON ATTACHMENT PATTERN
MIN.: V=15KN/m (ROOF DECK)
V=40KN/m (FLOOR DECK)
HSS 102x52x6.4(4"x2"x14") x1200(48")
LONG BETWEEN JOISTS
(PROVIDE ON ALL BRACE FRAME/MOMENT FRAME LINES U/N)
FOR OPENINGS IN NEW BUILDINGS:
• PROVIDE TRIMMER ANGLE CLOSER(MATCH TYP. PERIMETER ANGLE)
FOR OPENINGS IN EXISTING:
• MAKE GOOD ALL EXPOSEDSTEEL/CONCRETE SURFACES
• GRIND SMOOTH
PROVIDE NEW C-FRAMING ALLSIDES OF OPENING
SPAN:
<1200(4'-0"):C100x9 E.S.<1800(6'-0"):C150x12 E.S.
<2400(8'-0"):C200x17 E.S.
PROVIDE ADD'L L 52x52x6.4
(L2"x2"x14") DIAGONALS (1 E.S. OF
WEB) IF OPENING FRAMING DOESNOT ALIGN WITH PANEL POINTS
SCALE: N.T.S.
DETAIL: TRIMMING OF FLOOR DECK OPENINGS (NEW/EXISTING)
S003
G
(SEE ALSO ROOF OPENING FOR BASIC LAYOUT)
WHERE CROSS MEMBERS DO NOT ALIGN ON
PANEL POINTS TRIANGULATE TO BOTTOM
CHORD PANEL POINT WITH ADD'L
L52x52x6.4(L2"x2"x14") (1 E.S. OF WEB) (2 SETS
OF STRUTS, 1 TO EACH ADJACENT B.C. PANEL
POINT)
TRIM ALL OPENINGSWITH CHANNELS
TRIM ALL DECK EDGES WITH
TYPICAL PERIMETER ANGLE
CHANNEL FRAMING E.S. OF
UNIT/OPENINGSSPAN:
<1200(4'-0"):C100x9 E.S.
<1800(6'-0"):C150x12 E.S.<2400(8'-0"):C200x17 E.S.
BRIDGING (REFER
TO DETAILS FORINTERFERENCES)
MECH. UNITMAX. WEIGHT: 2.4 KPa(50psf)
JOIST ADJACENT TO MECH.
UNITS TO BE DESIGNED FORADD'L DRIFTS (ALL AROUND):
4.8kPa
(100psf)2.4kPa
(50psf)
3000 (10'-0")
(INCREASE SNOW LOADS
BY 25% FOR POST DISASTER)
SPAN
SCALE: N.T.S.
DETAIL: TYPICAL MECHANICAL UNIT FRAMING
S003
H
(SEE ALSO OPENING TRIMMING DETAILS)
STUB CHANNEL TO SUIT
OVERHANG
SHEAR TAB MAY BE DELETED
WHERE JOIST SHOES DESIGNED
FOR ROLL OVER FORCES
D05-6 TYPICAL ROOF SAFETY ANCHOR
D05-7 TYPICAL JOIST/BEAM/EDGE DETAILS (U/N ON PLANS/SECTIONS)
FINISH GRADE
SEE ARCH./SOILS REPORT
FOR DETAILS
500(20"Ø) CONC. PIER
CONCRETE: fc' = 20 MPa, F-2
COMPACTED SUBGRADE
152Øx6.4 (6"x14") STEEL PIPE
FILLED WITH CONC. AFTER SET IN
PLACE. (PAINTED AS PER NOTES)
CONCRETE: fc' = 20 MPa, F-2
DOME CONCRETE FILLING TO
PROVIDE RUN-OFF
15
0(6
")
15
00
(5'-0")
±1
50
0(5
'-0
") M
AX
.
500(20")
(SE
E A
RC
H.)
S003
I
SCALE: N.T.S.
DETAIL: BOLLARD AT GRADE
D06) TYPICAL BOLLARD DETAILS:DRAWING LIST:
S000 GENERAL NOTES AND DETAILS
S001 GENERAL NOTES AND DETAILS
S002 GENERAL NOTES AND DETAILS
S003 GENERAL NOTES AND DETAILS
S004 GENERAL NOTES AND DETAILS
S005 GENERAL NOTES AND DETAILS: SCHEDULES
S006 CONCRETE BEAM SCHEDULE AND DETAILS
S007 CAMBER DIAGRAMS
S100 FOUNDATION / GROUND FLOOR PLAN
S100R1 SHEAR WALL / CORE WALL FOOTING REINFORCING PLAN
S101 SECOND FLOOR PLAN
S101R1 SECOND FLOOR (REINFORCING PLAN)
S101R2 SECOND FLOOR (REINFORCING PLAN)
S102 THIRD FLOOR PLAN
S102R1 THIRD FLOOR PLAN (TYPICAL REINFORCING U/N)
S102R2 THIRD FLOOR PLAN (TYPICAL REINFORCING U/N)
S103 FOURTH FLOOR PLAN
S103R1 FOURTH FLOOR (REINFORCING PLAN)
S103R2 FOURTH FLOOR (REINFORCING PLAN)
S104 ROOF PLAN
S104R1 ROOF (REINFORCING PLAN)
S104R2 ROOF (REINFORCING PLAN)
S105 PENTHOUSE ROOF PLAN
S200 SECTIONS AND DETAILS
S201 SECTIONS AND DETAILS
S300 CORE WALL DETAILS: CW1
S301 CORE WALL DETAILS: CW2
S302 SHEAR WALL DETAILS
ST100 TEST FACILITY: FOUNDATION / GROUND FLOOR PLAN
ST101 TEST FACILITY: ROOF PLAN
ST200 TEST FACILITY: SECTIONS AND DETAILS
FINAL SIZING OF REINFORCING TO BEBASED ON ROOF ANCHOR SUPPLIERS
DESIGN. SUBMIT ANCHOR LOADING
WITH STRUCTURAL STEEL SHOPDRAWINGS.
DOME CONCRETE
FILLING TO PROVIDE
RUN-OFF
±15
00
(5'-0")
MA
X.
300Øx12(12"Øx12") B
c/w: 6-16mm(58")Ø STAINLESS STEEL
HILTI HY 200 ADHESIVE ANCHORS
(100(4") EMBEDMENT INTO CONCRETE)
BOLLARD PAINT FINISH
• PAINT STEEL WITH SHERWIN WILLIAMS ZINCCLAD II ETHYL SILICATE
INORGANIC ZINC-RICH COATING.
(PART E B69V3 BINDER, PART
F B69D11 ZINC-DUST)• APPLY IN STRICT ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
• BOLLARDS TO BE SAFETY YELLOW
(CO
NF
IRM
WIT
H A
RC
H.)
152Øx6.4 (6"x14") STEEL PIPE
FILLED WITH CONC. AFTER SET INPLACE. (PAINTED AS PER NOTES)
CONCRETE: fc' = 20 MPa, F-2
200
(8")
(MIN
.)
SCAN REINFORCINGPRIOR TO DRILLING
(DO NOT DAMAGE BARS)
S003
J
SCALE: N.T.S.
DETAIL: BOLLARD ON SLAB
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS
N.T.S.S003
![Page 5: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/5.jpg)
G E
N E
R A
L
N O
T E
S
A N
D
D E
T A
I L
S
12"x8"x58" PLATE
c/w: 2-5 8"Ø HAS-E RODS WITHHILTI HY-200A ADHESIVE
(MIN. 6" EMBEDMENT)
8" CONC. BEAM AT ELEVATORS (SEEPLANS/SCHEDULES)
2-6"x12" BENT PLATE
+1-3 4"Ø BOLT FOR 2"VERTICALLY SLOTTEDCONNECTION
S 250x52
HSS 8"x4"x38"
CONC. SLAB/DROP PANEL(SEE PLANS FOR REINF.)
12"x8"x58" BASEPLATE
c/w: 2-5 8"Ø HAS-E RODS WITH HILTIHY-200A ADHESIVE
(MIN. 6" EMBEDMENT)(PROVIDE 1" THICK GROUT BED BELOWPLATE)
CONC. BEAM/SLAB AT ELEVATORS(SEE PLANS/SCHEDULE)
285
S 250x52
CONC. SLAB/DROP PANEL(SEE PLANS FOR REINF.)
10"x6"x34" STEEL PLATE
c/w: 4-3 4"Ø ANCHOR BOLTS(MIN. 6" EMBEDMENT)
CONT. FILLET WELD TO PLATEWELD BEAM CONNECTION TO PLATE
CONC. BEAM/SLAB AT ELEVATORS(SEE PLANS/SCHEDULE)
2"
S 250x52
CONC. SLAB/DROP PANEL(SEE PLANS FOR REINF.)
10"x6"x34" STEEL PLATE
c/w: 4-3 4"Ø ANCHOR BOLTS(MIN. 6" EMBEDMENT)CONT. FILLET WELD TO PLATE
WELD BEAM CONNECTION TO PLATE
8" CONC. BEAM AT ELEVATORS(SEE PLANS/SCHEDULE)
2"
256
6(M
IN)
NOTES ON DIVIDER/HOIST BEAMS:
1. ALL BEAM SIZES TO BE S250x52.
2. MAXIMUM SPACING OF DIVIDER BEAMS TO BE 10'-0"o.c. REFER TO ELEVATOR SUPPLIER'S REQUIREMENTS. IF
INCREASED SPACING (TO SUIT ELEVATOR SUPPLIER REQUIREMENT) OF BEAMS RESULTS IN LARGERBEAMS/MODIFICATIONS TO ANCHOR/POSTS, MODIFICATIONS TO BE DONE AT NO ADD'L COST TO THE CONTRACT.
3. PROVIDE HSS 8"x4"x38" POST AT LOCATIONS WHERE CONNECTION INTO CONCRETE SLAB OR BEAM IS NOT POSSIBLE.
4. ELEVATOR SHOP DRAWINGS ARE REQUIRED TO BE SUBMITTED WITH STEEL SHOP DRAWINGS TO VERIFY ELEVATORDATA/REACTIONS/BEAM GEOMETRY/ELEVATIONS. STEEL SHOP DRAWINGS SUBMITTED WITHOUT THIS INFORMATIONWILL BE RETURNED UNREVIEWED.
5. WHERE ELEVATOR SUPPLIER REQUIREMENTS RESULT IN MODIFICATIONS TO STEELFRAMING/CONNECTIONS/REINFORCING/CONC. ELEVATIONS NOTED, MODIFICATIONS TO BE DONE AT NO ADD'L COST
TO THE CONTRACT.
6. DETAILS/INFORMATION PROVIDED FOR BUDGETING PURPOSES ONLY. DESIGN/DETAILING/CERTIFICATION OF THEELEVATOR SUPPORT FRAMING (INCLUDING DIVIDERS/HOISTS/SUPPORTS/ANCHORS/INSERTS) TO BE BY DIVISION 05.COORDINATE ALL REQUIREMENTS WITH ELEVATOR SUPPLIER.
WHERE PROPOSED BEAM
SPACING WILL NOT RESULT INMIN. 450 (1'-6") CLEARANCE,PROVIDE ADDITIONAL BEAMS
AS REQUIRED TO MEETCLEARANCE NOTED. PROVIDE 2-15Mx800 (32") LONG ADD'L
@ PLATE BENDS/HOOKS
VARIES
(SEE PLANS)
PROVIDE 2-15Mx800 (32") LONG ADD'L
@ PLATE BENDS/HOOKS
ELEVATOR DIVIDER POST (ASREQUIRED)
15M VERTS INTO SLAB (MATCHSPACING OF WALL BARS)
SLAB ON GRADE
(SEE PLANS)
ELEVATOR WALLS (SEEPLANS)
1
2
30
0(1
2")
S004
G
SCALE: N.T.S.
DETAIL: SLAB ON GRADE AT ELEVATOR DOOR
S004
F
SCALE: N.T.S.
DETAIL: ELEVATOR DIVIDER BEAM AT OPENING
S004
E
SCALE: N.T.S.
DETAIL: ELEVATOR DIVIDER BEAM AT CONC. SLAB
S004
D
SCALE: N.T.S.
DETAIL: ELEVATOR DIVIDER BEAM AT CONC. BEAM/WALL
TYPICAL ELEVATOR SHAFT DETAILS
300
(12")
300
(12")
1350(4'-6")
CLA
SS
`B
'
TE
NS
ION
LA
P.
15M @ 12" T.E.W.(HOOK AT ENDS)
1500
(5'-0
" M
AX
.)
180
0 (
6'-0")
MIN
.
(FR
OS
T C
OV
ER
)
30
0(1
2")
COMPACTED ENGINEEREDFILL qall ≥ 150 kPa
GEOTECHNICAL ENGINEERTO REVIEW PRIOR TO
CONC. PLACEMENT
300
(12")
CLA
SS
`B
'
TE
NS
ION
LA
P.
300
(12
")
1370(4'-6")
15M @ 300 (12") B.E.W.
(HOOK AT ENDS)
180
0 (
6'-0")
MIN
.
(FR
OS
T C
OV
ER
)
SIDEWALK (REFER TOLANDSCAPE PLANS)
300
(12")
15M @ 300 (12") H.E.F.
15M @ 300 (12") V.O.F. (+DWLS)
1500
(5'-0
") M
AX
.
COMPACTED ENGINEEREDFILL qall ≥ 150 kPaGEOTECHNICAL ENGINEER
TO REVIEW PRIOR TOCONC. PLACEMENT
15M @ 300 (12") V.O.F.
(+ DWLS)
15M @ 300 (12") H.E.F.
20M @ 300 (12") V.I.F.(+ DWLS)
20M @ 300 (12") V.I.F. (+DWLS)
WEEP HOLES
@ 1800 (6'-0") MAX.
WEEP HOLES
@ 1800 (6'-0") MAX.
NOTE:
THESE DETAILS ARE TO BE USED WHERE ELEMENTS ARE
NOT OTHERWISE ON DRAWINGS.
300
(12")
CLA
SS
`B
'
TE
NS
ION
LA
P.
300
(12
")
800 (32")
15M @ 300 (12") B.E.W.
(HOOK AT ENDS)
180
0 (
6'-0")
MIN
.
(FR
OS
T C
OV
ER
)
SIDEWALK (REFER TOLANDSCAPE PLANS)
300
(12")
15M @ 300 (12") H.E.F.
15M @ 300 (12") V.O.F. (+DWLS)
VA
RIE
S
600
(24")
MA
X.
COMPACTED ENGINEEREDFILL qall ≥ 150 kPaGEOTECHNICAL ENGINEER
TO REVIEW PRIOR TOCONC. PLACEMENT
15M @ 225 (9") V.I.F. (+DWLS)
WEEP HOLES
@ 1800 (6'-0") MAX.
15M @ 300 (12") T.E.W.
250
(10
")
fc'=25MPa(3625psi), N
fc'=35MPa(5076psi), C-1
GUARDRAIL (REFER TOARCH/CIVIL/LANDSCAPE)GUARDRAIL (REFER TO
ARCH/CIVIL/LANDSCAPE)
fc'=35MPa(5076psi), C-1
fc'=25MPa(3625psi), N
fc'=35MPa(5076psi), C-1
fc'=25MPa(3625psi), N
GUARDRAIL (REFER TO
ARCH/CIVIL/LANDSCAPE)
S004
J
SCALE: N.T.S.
SECTION: TYPICAL PLANTER RETAINING WALL
S004
I
SCALE: N.T.S.
SECTION: TYPICAL SIDEWALK/RAMP RETAINING WALL (HIGH)
S004
K
SCALE: N.T.S.
SECTION: TYPICAL SIDEWALK/RAMP RETAINING WALL (LOW)
TYPICAL EXTERIOR LANDSCAPE ELEMENTS
TYPICAL DETAILS: FOUNDATIONS
REINFORCING AS
PER PLANS
DOWELS AS PER
PLANS
REINFORCING:15M @ 200(8")o.c. BOT.
LONG.
250(10") MIN.250(10") MIN.
t VARIES (REFER
TO PLANS)
30
0(1
2")
600(24")
MIN
VERTS TO BE FULL HEIGHT ATBRACE FRAME/MOMENT FRAMELOCATIONS
UNDISTURBED MATERIAL/ENGINEERED FILL
(APPROVED BY GEOTECHNICAL ENGINEER)TIES AS PER SCHEDULEMIN: 10M TIES @ 300mm(12")o.c.
U/N
VERTS AS PER SCHEDULE
MIN: 8-20M VERT. U/N
ANCHOR BOLT EMBEDMENT DEPTH(NOTED IN BASEPLATE SCHEDULE)
(PLACE TIES @ 12 SPACING IN THIS ZONE U/N)
ANCHOR BOLTS (AS PER SCHEDULE)
MIN: NO BRACE/MOMENT FRAME:
4-20mm(3 4")Ø ANCHORS
BRACE/MOMENT FRAME:
8-25mm(1")Ø SEISMIC HEADED ANCHORS
400(16")
50(2")
900mm(36")
1
2
75m
m
(28
6)
300
mm
(12
") U
/N
SLAB ON GRADE(SEE PLANS)
BITUMINOUS BOND BREAK (TYP)
>65mm(238) U/N (TYP)
100mm(4") MIN.
COLUMN AS PER SCHEDULE
B AS PER SCHEDULE
MIN: NO BRACE/MOMENT FRAME:
20mm(3 4") THICK U/N
BRACE/MOMENT FRAME:50mm(2") THICK U/N
>75mm(3")
U/N (TYP)
VA
RIE
S T
O S
UIT
GE
OT
EC
HN
ICA
L C
ON
DIT
ION
S>
150
0m
m(5
'-0
") S
OIL
CO
VE
R A
T E
XT
ER
IOR
PIE
RS
/WA
LLS
>1
80
0m
m(6
'-0
") S
OIL
CO
VE
R A
T I
NT
ER
IOR
PIE
RS
WIT
HB
RA
CE
/MO
ME
NT
FR
AM
E
(IN
CR
EA
SE
SO
IL D
EP
TH
WH
ER
E R
EQ
UIR
ED
TO
EN
SU
RE
CL
EA
RA
NC
E O
F A
NC
HO
R B
OLT
S T
O T
OP
OF
FO
OT
ING
)
SHEAR LUG (REFER TO B SCHEDULE)
VERTS TO BE FULL HEIGHT ATBRACE FRAME/MOMENT
FRAME LOCATIONS
UNDISTURBED MATERIAL/ENGINEEREDFILL (APPROVED BY GEOTECHNICALENGINEER)
TIES AS PER SCHEDULE
MIN: 10M TIES @300mm(12")o.c. U/N
VERTS AS PER SCHEDULEMIN: 8-20M VERT. U/N
DOWELS FOR VERTICALS PERMITTED WHERE NOBRACE/MOMENT FRAME IS PRESENT OR PIER HEIGHT >
2400(8'-0")LAP: NO BRACE/MF: COMPRESSION (>600(24"))
BRACE/MF: > CLASS `B' TENSION> 1/5 d> 600(24")
ANCHOR BOLT EMBEDMENT DEPTH
(NOTED IN BASEPLATE SCHEDULE)
(PLACE TIES @ 12 SPACING IN THIS ZONE U/N)
ANCHOR BOLTS (AS PER SCHEDULE)MIN: NO BRACE/MOMENT FRAME:
4-20mm(34")Ø ANCHORS
BRACE/MOMENT FRAME:
8-25mm(1")Ø SEISMIC HEADED ANCHORS
400(16")
50(2")
900mm(36")
25mm(1") GROUT BED (TYP)
(NON-SHRINK)
75m
m
(28
6)
300
mm
(12
") U
/N
SLAB ON GRADE
(SEE PLANS)
BITUMINOUS BOND BREAK (TYP)
>65mm(238) U/N (TYP)
COLUMN AS PER SCHEDULE
B AS PER SCHEDULE
MIN: NO BRACE/MOMENT FRAME:
20mm(3 4") THICK U/N
BRACE/MOMENT FRAME:
50mm(2") THICK U/N
>75mm(3")
U/N (TYP)
SHEAR LUG (REFER TO B SCHEDULE)
FDN WALL/FOOTING
REINFORCING TO BECONTINUOUS THROUGHPIERS/FTGS (TYP)
DOWELS FOR VERTICALS PERMITTED WHERE NOBRACE/MOMENT FRAME IS PRESENT OR PIER HEIGHT >
2400(8'-0")LAP: NO BRACE/MF: COMPRESSION (>600(24"))
BRACE/MF: > CLASS `B' TENSION> 1/5
25mm(1") GROUT BED (TYP)(NON-SHRINK)
100mm(4") MIN. CLEARANCE
TO END OF BOLT
PROVIDE DRAINAGE TILEAT ALL FDN WALLS
(SEE MECH/ARCH)
VA
RIE
S T
O S
UIT
GE
OT
EC
HN
ICA
L C
ON
DIT
ION
S
>1
50
0m
m(5
'-0
") S
OIL
CO
VE
R A
T E
XT
ER
IOR
PIE
RS
/WA
LLS
>1
80
0m
m(6
'-0
") S
OIL
CO
VE
R A
T I
NT
ER
IOR
PIE
RS
WIT
HB
RA
CE
/MO
ME
NT
FR
AM
E
(IN
CR
EA
SE
SO
IL D
EP
TH
WH
ER
E R
EQ
UIR
ED
TO
EN
SU
RE
CL
EA
RA
NC
E O
F A
NC
HO
R B
OLT
S T
OT
OP
OF
FO
OT
ING
)
100mm(4") MIN. CLEARANCETO END OF BOLT
S004
C
SCALE: N.T.S.
DETAIL: TYPICAL FOUNDATION WALL STRIP FOOTING (TYP)
S004
B
SCALE: N.T.S.
DETAIL: TYPICAL STEEL COL/BASEPLATE/PIER/FOOTING: INTERIOR
S004
A
SCALE: N.T.S.
DETAIL: TYPICAL STEEL COL/BASEPLATE/PIER/FOOTING: EXTERIOR
FINISHED STEPS (REFER TOARCH/CIVIL/LANDSCAPE)
COMPACTED ENGINEERED FILL
qall ≥ 150 KPa
GEOTECHNICAL ENGINEER TO REVIEWPRIOR TO CONCRETE PLACEMENT
NON-FROST SUSCEPTIBLEENGINEERED FILL (APPROVED BYGEOTECH)
15M @ 300(12")o.c. DOWELS
PAVING (REFER TOLANDSCAPE PLANS)
18
00
(6
84
0)
(MIN
.) F
RO
ST
CO
VE
R
150(570)
200(760)
150(570)
150(5
70)M
INTH
RO
AT
15M @ 300(12")o.c. VERT.
3-15M BOT. LONG.(TYP.)
fc'=25MPa(3625psi), N
15M @ 300(12") B.E.W.
1-10M NOSING BAR (EPOXY COATED)TYP. EACH STEP
H
S004
DETAIL: CONCRETE STAIRS
SCALE: N.T.S.
200(760)
PAVING (REFER TO LANDSCAPE PLANS)
2-15M HOR. ADD'L AT
TOP (TYP)
600(24")(MIN)15M @ 400(16")o.c. HOR.
REFER TO ARCH/CIVIL/LANDSCAPE FORRISE/RUN OF STEPS
fc'=35MPa(5076psi), C-1
U/N OTHERWISE WHERE FINISHEDSTEPS ARE NOT PROVIDED, PROVIDENON-SLIP BROOM FINISH
PROVIDE 200(8") WALL E.S. OF STAIR• TOP OF WALL TO EXTEND TO HEIGHT
NOTED ON ARCH/CIVIL/LANDSCAPE
GUARDRAIL (REFER TOARCH/CIVIL/LANDSCAPE)
NOTE: PROVIDE SAMECONCRETE STAIR WHERE
ARCH CONC/PRECASTPAVERS NOT REQUIRED
TYPICAL DETAILS: EXPANSION JOINTS AT FLOORS
NOTE:
THESE DETAILS ARE TO BE USED WHERE ELEMENTS ARE
NOT OTHERWISE ON DRAWINGS.
NOTE:
THESE DETAILS ARE TO BE USED WHERE ELEMENTS ARE
NOT OTHERWISE ON DRAWINGS.
TYPICAL DETAILS: FOLDING PARTITION SCREENS
TYPICAL DETAILS: RETAINING WALLS
NOTE:
STEEL SHOP DRAWING SUBMISSIONS TO BE SUBMITTED
WITH SCREEN REQUIREMENTS. SCREEN DATA TO INCLUDE
WEIGHTS AND DEFLECTION CRITERIA.
1" COMPRESSIBLE
MATERIAL ON TOP
L 152x102x9.5(6"x4"x38") (LLV)
x100mm(4") WIDE E.S. OF COLUMN
c/w: 1-HILTI HDA-P ANCHORS
(M12x120/50) + SLOTTED CONNECTION
FOR 25mm(1") MOVEMENT OF SLAB
DOWNWARD
NEW/EXISTING
CONCRETE SLAB
PRESSURE GROUT AS
REQUIRED TO PROVIDE
LEVEL BEARING SURFACE
FOLDING SCREEN
WMAX = 0.4KPa (8psf)
NEW/EXISTING SLAB
1" GROUT BED
SCREEN SUPPORT BEAMS:
l < 6100mm(20'-0") = W360x45
NEW HSS 102x102x6.4
(4"x4"x14") E.E.
(PLACE IN STUD WALLS)
E
S002C
FPA 1: 250x102x12(10"x4"x12")
c/w: 2-HILTI HDA-P ANCHORS
(M12x120/50)
x
x
VA
RIE
S 3
10
0m
m(1
0'-0")
MA
X.
VA
RIE
S 4
00
0m
m(1
3'-0")
MA
X.
DIAGONALS
≥ (10
")
125
(5")
≥ (10
")
S004
N
SCALE: 1:25
DETAIL: TYPICAL SCREEN BEAM SUPPORT AT END
HSS 102x102x6.4(4"x4"x14")
HANGERS @ ENDS/MID POINT
NEW/EXISTING CONCRETE SLAB
PRESSURE GROUT AS
REQUIRED TO PROVIDE
LEVEL BEARING SURFACE
FOLDING SCREEN
WMAX = 12 lb/ft
W 250x24 SCREEN
SUPPORT BEAMS
L 76x76x6.4(3"x3"x14")
KICKERS AT ENDS 1
1
S004
P
(MAY ONLY BE USED IF END POST NOT PERMITTED)
FPA 3: 225x200x10(9"x8"x38")
c/w: 2-HILTI HDA-P ANCHORS
(M12x125/50) @ 150(6") o.c.
FPA 2: 225x225x16(9"x9"x58")
c/w: 4-HILTI HDA-P ANCHORS
(M12x125/50)150(6")
≥ (10
")
125
(5")
S004
O
SCALE: 1:25
DETAIL: SCREEN BEAM SUPPORT: ALTERNATE
FPA 3
1
1
VA
RIE
S
L 76x76x6.4(3"x3"x14") KICKERS @
1200mm(48")o.c. (MAX.)
(+1 ADD'L AT EA. END/HANGER)
SCREEN BEAM (SEE DETAIL)
NEW/EXISTING
CONCRETE SLAB
1
1
FPA 3
HANGER (SEE DETAIL)
≥ (10
")
PROVIDE @ ENDS (SPACING NOTE)S004
P
SCALE: 1:25
DETAIL: SCREEN BEAM SUPPORT: LATERAL SUPPORTS
x
x
FPA 1: 350x300x16(14"x12"x58")
c/w: 4-20mm(3 4")Ø ANCHORS
BEAM/CLIP ANGLE
(WELD TO PLATE)
CONC. COLUMN
(SEE PLANS)
>400mm(16")
VARIES(SEE PLANS)
300(12")
75(3")
CONCRETE ELEMENT
TO BE MIN. 400mm(16")
WIDE
S004
Q
SCALE: 1:25
DETAIL: SCREEN BEAM SUPPORT @ CONC. COLUMN/WALL
LIGHT WEIGHT FILL
(EPS GEO FOAM OR
EQUIVALENT) AS DIRECTED
BY GEOTECHNICAL ENGINEER
S004
R
SCALE: N.T.S.
SECTION: BERM RETAINING WALLS
UNDISTURBED BEARING SURFACE
• qSLS = 200 kPa
qULS = 350 kPa
450
REINFORCED SLOPE TO BE
INSTALLED/APPROVED BY
GEOTECHNICAL ENGINEER ON SITE
600
20M @ 250 BUL
20M @ 100 BLL
ENGINEERED BACKFILL
AS PER GEOTECHNICAL
REPORT
5000 (
MA
X.)
DRAINAGE
(REFER TO CIVIL) fc' = 30 MPa, F-2
WEEP HOLES @ 1800 o.c. (MAX.)
CONC. WALL
fc' = 35 MPa, C-1
20M @ 200 V.I.F.
15M @ 400 H.E.F.
15M @ 400 V.O.F.
300 (MAX.)REINFORCED SOIL/BACKFILL
2600600 500
CLASS 'B' TENSION LAPS (TYP.)
(MIN. 900)
VARIES ±20(3 4") TYP(REFER TO ARCH.)
VARIES
±100(87)TYP
VARIES±100(87)
TYP
EXP. JOINT VARIES IN
WIDTH (SEE PLANS)
EXPANSION JOINT COVER (SEE ARCH.)
-INSTALL AS PER MANUFACTURER'S
INSTRUCTIONS
LOCALLY VARY CHAIRS AS REQUIRED TO
MAINTAIN COVER AT EXPANSION JOINT
COVER
CAST-IN INSERTS AS PER
SUPPLIER'S REQUIREMENTS
IF ON EXISTING SLAB
-GRIND/SAWCUT DOWN EXISTING
CONCRETE
-DO NOT CUT/DAMAGE EXISTING BARSEXPANSION JOINT (REFER TO ARCH.)
(INSTALL AS PER MANUFACTURER'S
INSTRUCTIONS)
S004
L
SCALE: N.T.S.
TYPICAL DETAIL: EXPANSION JOINT COVER: FLOORS: CONCRETE
VARIES ±20(3 4") TYP(REFER TO ARCH.)
VARIES±100(87)
TYP
VARIES±100(87)
TYP
EXP. JOINT VARIES IN WIDTH
(SEE PLANS)
EXPANSION JOINT COVER
(SEE ARCH.)
-INSTALL AS PER
MANUFACTURER'S
INSTRUCTIONS
CAST-IN INSERTS AS PER
SUPPLIER'S REQUIREMENTS
IF ON EXISTING DECK
-SAWCUT DOWN EXISTING
CONCRETE (DO NOT OVER CUT)
-FLAME CUT EXISTING ANGLE
EXPANSION JOINT (REFER TO ARCH.)
(INSTALL AS PER MANUFACTURER'S INSTRUCTIONS)
EDGE ANGLE
-LOCALLY NOTCH AS
REQUIRED TO PLACE EXP.
JOINT COVER
S004
M
SCALE: N.T.S.
TYPICAL DETAIL: EXPANSION JOINT COVER: FLOORS: CONCRETE/DECK
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS
N.T.S.S004
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS
N.T.S.S004
![Page 6: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/6.jpg)
G E
N E
R A
L
N O
T E
S
A N
D
D E
T A
I L
S
NOTES:
1. ALL FOOTINGS TO BEAR ON SUITABLE BEARING STRATA AS APPROVED BY
GEOTECHNICAL ENGINEER/IN ACCORDANCE WITH GEOTECHNICAL REPORT
WITH MINIMUM BEARING PRESSURES NOTED IN TABLE.
2. PROVIDE MINIMUM 1500(5'-0") FROST COVER TO ALL FOOTINGS EXPOSED TO
EXTERIOR CONDITIONS U/N ON DRAWINGS/GEOTECHNICAL REPORT.
3. CONCRETE STRENGTH: fc' = 35 MPa U/N.
4. TOPS OF INTERIOR FOOTINGS TO BE A MINIMUM OF 300mm(12") BELOW THE
U/S OF THE SLAB ON GRADE. STEP DOWN INTERIOR FOOTINGS TO EXTERIOR
FOOTINGS AS REQUIRED. FINAL BEARING ELEVATIONS TO BE BASED ON
GEOTECHNICAL INVESTIGATION.
5. FOOTING AND BOTTOM OF WALL ELEVATIONS TO BE ESTABLISHED FROM
PLANS AND GEOTECHNICAL REPORT. WALLS/COLUMNS ARE TO BE
TERMINATED SUCH THAT THEY ARE FOUNDED ON COMPETANT BEDROCK
(WITH APPROPRIATE FROST COVER) APPROVED BY GEOTECHNICAL ENGINEER
ON SITE.
6. GEOTECHNICAL ENGINEER TO CONFIRM ALL BEARING CAPACITIES ON SITE
PRIOR TO PLACING CONCRETE.
7. FOOTINGS ARE TO BE LOWERED AS REQUIRED IN THE AREAS OF PITS/SHAFTS
@ FOUNDATION LEVEL SUCH THAT THE U/S OF THE PIT /SHAFT IS AT THE TOP
OF THE FOOTING. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF
ELEVATIONS/STEPS IN FOOTINGS. CONTRACTOR IS REQUIRED TO PREPARE
FOOTING ELEVATION DRAWINGS PRIOR TO EXCAVATION.
8. 15M SIDE BARS @ 200mm (8") o.c. REQUIRED FOR FOOTINGS 600mm (24") DEEP
AND GREATER.
9. HOOK FOOTING BARS 90° WHERE EDGE OF FOOTING IS LESS THAN 600mm(24")
PAST EDGE OF SUPPORTED PIER/WALL.
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FOOTING SCHEDULE
NOTESMARK
F1 TYPICAL CORNER FOOTINGS
25M @ 200 B.E.W.
fc' = 35 MPa, N
4500x4500x1000
SIZE (LxWxT)CC2
NOTES:
1. PROVIDE CAISSON/FOOTING DOWELS TO MATCH VERTICAL REINFORCING.
2. REFER TO PLANS FOR ADDITIONAL DETAILS/NOTES.
3. PROVIDE ADD'L TIE GROUPS AS NOTED IN DETAIL A U/N.
4. BEND VERTICAL BARS INTO SLAB WHERE COLUMNS TERMINATE.
5. FOOTING AND BOTTOM OF COLUMN ELEVATIONS TO BE ESTABLISHED FROM PLANS AND GEOTECHNICAL
REPORT. COLUMNS ARE TO BE TERMINATED SUCH THAT THEY ARE FOUNDED ON UNDISTURBED NATIVE
MATERIAL (WITH APPROPRIATE FROST COVER) OR PILE/CAISSON CAPS APPROVED BY GEOTECHNICAL
ENGINEER ON SITE. REFER ALSO TO GEOTECHNICAL REPORT.
fc'=
35 M
Pa
, N
U/N
ROOF
EL. 16.2m
4TH
EL. 12.2m
3RD
EL. 8.2m
2ND
EL. 4.2m
GROUND
EL. 0.0
600mmØ
14-30M VERT. +DWLS
1-10M TIE @ 300o.c.
600mmØ
14-25M VERT. +DWLS
1-10M TIE @ 300o.c.
CC3CC1 CC4
600mmØ
14-30M VERT. +DWLS
1-10M TIE @ 300o.c.
600mmØ
14-30M VERT.
1-10M TIE @ 300o.c.
600mmØ
14-25M VERT.
1-10M TIE @ 300o.c.
600mmØ
14-25M VERT.
1-10M TIE @ 300o.c.
350x1175
12-30M VERT. +DWLS
3-10M TIES @ 300o.c.
350x1175
12-30M VERT.
3-10M TIES @ 300o.c.
SIZEMARK
SC1 HSS 152x152x8.0
STEEL COLUMN SCHEDULE: TOWER
NOTES
600mmØ
14-30M VERT.
1-10M TIE @ 300o.c.
600mmØ
14-25M VERT.
1-10M TIE @ 300o.c.
600mmØ
14-25M VERT.
1-10M TIE @ 300o.c.
fc'=
30 M
Pa
, N
U/N
PLACE ADD'L TIE GROUPS AT 12
SPACING AT TOP & BOTTOM OF EACH
LIFT OVER A HEIGHT OF B
B > LARGEST COLUMN DIMENSION
> 450mm(18")
> 1/6 HEIGHT OF STOREY
(MIN. 5 ADD'L GROUPS)
PROVIDE DOWELS
INTO FOOTINGS TO
MATCH VERTICALS
FOOTING (SEE PLANS)
CLASS `B'
TENSION LAPS
(MIN. 600 (24"))
(LAPS TO BE 1.5 ld)
TIES TO BE CONTINUOUS
THROUGH SLAB/DROPS
(AT HALF SPACING)
10
0(4
")
800(32")
20M DWLS TO
MATCH VERTICAL
BAR NUMBER
ROOF
CLASS `B' TENSION LAPS
(MIN. 600 (24"))
(LAPS TO BE 1.5 ld)
RE
FE
R T
O P
LA
NS
/
GE
OT
EC
HN
ICA
L R
EP
OR
T
FO
R E
LE
VA
TIO
NS
600(24") 600(24")
600(24") 600(24")
WHERE CONCRETE COLUMN
STRENGTH EXCEEDS SLAB STRENGTH
BY GREATER THAN 10 MPa, PUDDLE
CONCRETE IN SLAB/DROP/FLARE
AROUND COLUMNS AS SHOWN.
CONCRETE TO MATCH STRENGTH OF
COLUMN IN PUDDLE.
SPACING OF TIES TO BE:
<8xDIAM. OF LONG BARS
<24xDIAM. OF TIE
<1/2 LEAST COL. DIM.
<300mm(12")
DETAIL: POUR BREAK @ COLUMNS/WALLS
SCALE: N.T.S.
DETAIL: TYPICAL COLUMN REQUIREMENTS U/N
SCALE: N.T.S.
A
S005
B
S005
COLUMN/SHEAR WALLS
CONCRETE STRENGTH
AS PER SCHEDULES
FOUNDATION WALLS:
CONCRETE AS PER
SPECIFICATIONS
CONSTRUCTION JOINT
-JOINT LOCATIONS TO BE
SUBMITTED TO ENGINEER IN
WRITING PRIOR TO
CONSTRUCTION
DETAIL IS TO BE PERFORMED IN
ALL LOCATIONS WHERE
SHEARWALL/COLUMN CONCRETE
STRENGTHS EXCEED
FOUNDATION WALL STRENGTH
CONCRETE COLUMN SCHEDULE
300(12") (MIN.)
- INCREASE AS
REQUIRED TO SUIT
BEARING LEVELS
1. REFER TO PLANS FOR ELEVATIONS AND ORIENTATIONS.
2. ALL HSS COLUMNS TO BE CLASS 'C'.
NOTES:
PENTHOUSE INTERIOR COLUMN
SC2 HSS 203x203x9.5 MECH. SCREEN VERTICAL COLUMNS
(HOT DIP GALV.)
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
F2 TYPICAL EXTERIOR FOOTINGS
30M @ 250 B.E.W.
fc' = 35 MPa, N
5000x5000x1100
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
F3 TYPICAL EXTERIOR STRIP FOOTINGS
4-15M BOT. LONG.
fc' = 25 MPa, N
800x300
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
F4 FIN WALL STRIP FOOTING
15M @ 200 BLL TRANS.
15M @ 200 BUL LONG.
fc' = 25 MPa, N
1500x350
TYP. FLOOR
350x1175
12-30M VERT.
3-10M TIES @ 300o.c.
350x117512-30M VERT.
3-10M TIES @ 300o.c.
F5 ELEVATOR CORE FOOTING/TIE
(SEE PLANS FOR REBAR)1500 DP FTG
F6 STAIR CORE FOOTING/TIE
(SEE PLANS FOR REBAR)1500 DP FTG
FOOTING
EL. VARIES
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS
N.T.S.S005
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
GENERAL NOTES AND
DETAILS: SCHEDULES
N.T.S.S005
![Page 7: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/7.jpg)
4 3 2 11500 9000 6000 9000 1500
650 650 650 650
10-30M TOP (2 LAYERS) 10-30M TOP (2 LAYERS)10-30M TOP (2 LAYERS)
10-25M BOT. (2 LAYERS) 10-25M BOT. (2 LAYERS)10-30M BOT. (2 LAYERS)
2-10M STIRRUPS
@ 250 o.c. (MAX.) U/N
3 26000
650 650
10-30M TOP (2 LAYERS)
10-25M BOT. (2 LAYERS)
ELEVATION: CB3B: 700x600
(GRID D)SCALE: N.T.S.
ELEVATION: CB4A: 700x600
(GRID D)SCALE: N.T.S.
4 3 2 1
500
9000 6000 9000
500
650 600 600 650
10-30M TOP (2 LAYERS)
CLASS'B' TENSION
LAP
CLASS'B' TENSION
LAP
10-30M TOP (2 LAYERS)
10-30M BOT. (2 LAYERS) 10-30M BOT. (2 LAYERS)
2-10M STIRRUPS@ 250 o.c. (MAX.)
ELEVATION: CB2A: 700x600
(GRID C)SCALE: N.T.S.
4 3 2 11500 9000 6000 9000 1500
650 600 600 650
10-30M TOP (2 LAYERS)
CLASS'B' TENSION
LAP
CLASS 'B' TENSION
LAP
10-30M TOP (2 LAYERS)
10-30M BOT. (2 LAYERS) 10-30M BOT. (2 LAYERS)
2-10M STIRRUPS@ 250 o.c. (MAX.)
ELEVATION: CB3A: 700x600
(GRID C)SCALE: N.T.S.
C C C C C C C C
D D D D D D
ELEVATION: CB2B: 700x600
(GRID D)SCALE 1:100
4 3 2 1
D D D D
15M @ 200 H.E.F.(TYP)
15M @ 200 H.E.F.
(TYP)
CLASS `B'
TENSION LAP
CLASS `B'
TENSION LAP (TYP.)
15M @ 200 H.E.F.(TYP)
CONCRETE BEAM SCHEDULE (W x H)
LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5
70
0
70
07
00
2-10M STIRRUPS @150 o.c. (MAX.)
500
70
0
500
2-10M STIRRUPS @
200 o.c. (MAX.)
1000 1000 1000 1000
2-10M STIRRUPS@ 250 o.c. (MAX.)
15M @ 200 H.E.F.(TYP)
2-10M STIRRUPS
@ 250 o.c. (MAX.)
15M @ 200 H.E.F.(TYP)
500
9000 6000 9000
500
650 600 600 650
10-30M TOP (2 LAYERS)
CLASS'B' TENSION
LAP
CLASS'B' TENSION
LAP
10-30M TOP (2 LAYERS)
10-25M BOT. (2 LAYERS) 10-25M BOT. (2 LAYERS)
15M @ 200 H.E.F.
(TYP)
70
0
CLASS `B'
TENSION LAP (TYP.)
CLASS'B' TENSION
LAP
CLASS'B' TENSION
LAP
2-10M STIRRUPS
@ 250 o.c. (MAX.) U/N
2-10M STIRRUPS
@ 150 o.c. (MAX.)
10-30M TOP (2 LAYERS)
10-30M BOT. (2 LAYERS)
OF BEAM
OF COLUMN
STIRRUPS:
- PROVIDE 1 VERTICAL LEG AT
EACH HORIZONTAL BAR (TYP)
- ALL STIRRUPS TO BE CLOSED
LOOPS
OF COLUMN
≥0.33L1
U/N
600 (24")
TENSION LAP
L1
≥0.33L1(U/N)
≥0.33L2(U/N)
WHERE BEAMS CANTILEVER
PAST SUPPORT, HOOK BOT
BARS 90° AT ENDS
NOT MORE THAN 50% OF BARS TO
BE TERMINATED SHORT OF
MIDPOINT
UNLESS NOTED LAP ALL TOP BARS
FROM ADJACENT SUPPORTS @ OF
BEAM SUPPORT
L2
≥ 10db
≥ 150(6")
≥ 10db
≥ 150(6")
50mm(2")
CLEAR
50mm(2")
CLEAR
50mm(2")
CLEAR
≥ 0.33L1(U/N)
≥ 0.33L2(U/N)
S S
S/2(≥50(2")
S006
A
SCALE: N.T.S.
SECTION: TYPICAL BEAM REINFORCEMENT (U/N IN SCHEDULE)
A
4-10M STIRRUPS
@ 150 o.c. (MAX.)
PROVIDE STIRRUPS @ 12
SPACING FOR 600mm AT POST
S006
B
SCALE: N.T.S.
DETAIL: ROOF SLAB BAND: RSB1: 3000 x 550 (MIN)
4-10M CLOSED
STIRRUPS @ 150 o.c.
14-30M BOT. (1st LAYER)
14-30M BOT. (2nd LAYER)
14-30M TOP (1st LAYER)
c/w: HOOK AT ENDS
(FULL LENGTH OF BEAM)
TOP OF STIRRUP TO
BE AT U/S OF TLL
550mm (MEASURED
FROM SLAB LOW POINT)
1-15M ADD'L CONT.
GL
4-10M STIRRUPS
@ 150 o.c. (MAX.)
S006
C
SCALE: N.T.S.
DETAIL: ROOF SLAB BAND: RSB2: 3000 x 490 (MIN)
4-10M CLOSED
STIRRUPS @ 150 o.c.
14-30M BOT. (1st LAYER)
14-30M BOT. (2nd LAYER)
14-30M TOP (1st LAYER)
c/w: HOOK AT ENDS
(FULL LENGTH OF BEAM)
TOP OF STIRRUP TO
BE AT U/S OF TLL
490mm (MEASURED
FROM SLAB LOW POINT)
1-15M ADD'L CONT.
GL GL
4-10M STIRRUPS
@ 200 o.c. (MAX.)
S006
D
SCALE: N.T.S.
DETAIL: 4TH FLOOR SLAB BAND: 4SB1: 3000 x 490
4-10M CLOSED
STIRRUPS @ 200 o.c.
14-30M BOT. (1st LAYER)
14-30M BOT. (2nd LAYER)
14-30M TOP (1st LAYER)
c/w: HOOK AT ENDS
(FULL LENGTH OF BEAM)
TOP OF STIRRUP TO
BE AT U/S OF TLL
490mm (MEASURED
FROM SLAB LOW POINT)
1-15M ADD'L CONT.
GL
GL
4-10M STIRRUPS
@ 150 o.c. (MAX.)
S006
E
SCALE: N.T.S.
DETAIL: 2ND FLOOR SLAB BAND: 2SB1: 1800 x 550
4-10M CLOSED
STIRRUPS @ 150 o.c.
12-25M BOT. (1st LAYER)
12-25M BOT. (2nd LAYER)
12-30M TOP (1st LAYER)
c/w: HOOK AT ENDS
(FULL LENGTH OF BEAM)
TOP OF STIRRUP TO
BE AT U/S OF TLL
490mm (MEASURED
FROM SLAB LOW POINT)
1-15M ADD'L CONT.
GL
2SB2
10
GL
5-10M STIRRUPS
@ 150 o.c. (MAX.)
S006
F
SCALE: N.T.S.
DETAIL: 2TH FLOOR SLAB BAND: 2SB2: 3000 x 550
5-10M CLOSED
STIRRUPS @ 150 o.c.
16-25M BOT.
16-25M TOP (1st LAYER)
c/w: HOOK AT ENDS
(FULL LENGTH OF BEAM)
TOP OF STIRRUP TO
BE AT U/S OF TLL
490mm (MEASURED
FROM SLAB LOW POINT)
1-15M ADD'L CONT.
GL
2SB1
BOT. BARS OF 2SB2 TO GO
BELOW BOT. BARS OF 2SB1
TOP BARS OF 2SB2 TO GO
ABOVE TOP BARS OF 2SB1
10
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
N.T.S.S006
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
CONCRETE BEAM
SCHEDULE AND DETAILS
![Page 8: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/8.jpg)
10 10
BBBBB
AAAAA B A A B B
BB
AA
B
AAAAA BA A
B B
BBBB
B
200
BBBBB
A BAAAAABAB
BB
BB
BB AA
BB
ABB AAAAABA
BBBBB
BB
200
BBBCBB
A BAAACAABAB
BB
BB
BB AA
BB
ABB AAACAABA
BBBCBB
BBBCBB
A BAAACAABAB
BA
BB
BB A
BA
ABB AAACAABA
BBBCBB
BB
CAMBER SIZES
A= 20mm
B= 16mm
C= 30mm
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
N.T.S.S007
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
CAMBER DIAGRAMS
CAMBER DIAGRAM: SECOND FLOOR
CAMBER DIAGRAM: THIRD FLOOR
CAMBER DIAGRAM: FOURTH FLOOR
CAMBER DIAGRAM: ROOF
![Page 9: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/9.jpg)
6950
H
J
FOUNDATION/GROUND FLOOR PLAN
SCALE: 1:100
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
UP
F1
150mm CONC. SLAB ON GRADE
c/w: 152x152 MW18.7x18.7
T.O.C. EL. 0000 (DATUM)
200
200
20
0
20
0
CW1CW2
CW3
PRE-ENG. STEEL STAIR
(REFER TO ARCH.)
UP
UP
CONCRETE STAIR
(REFER TO DETAILS)
CONCRETE STAIR
(REFER TO DETAILS)
RETAINING WALLS
• REFER TO ARCH/CIVIL/LANDSCAPE
FOR EXTENTS
S200
1
S200
1
S200
2
S200
2
S200
2
PROVIDE MIN. 1800
FROST COVER TO
EXTERIOR FOOTINGS
PROVIDE MIN. 1800 FROST
COVER TO EXTERIOR
FOOTINGS
35
0
35
0
35
0
400
400 400
STEP FTG
DOWN
ST
EP
FT
GD
OW
N
PROVIDE MIN. 1800 FROST
COVER TO EXTERIOR
FOOTINGS
STEP FTG
DOWN
ST
EP
FT
G
DO
WN
STEP FTG
DOWN
ST
EP
FT
GD
OW
N
40mm DEEP SAWCUTS
c/w: LOADFLEX JOINT FILLER
ST
EP
FT
G
DO
WN
35
03
50
400
400
STEP FTG
DOWN
T.O.C. EL. 0000 (DATUM)
CC2
CC2
CC1
CC1
CC3
SCT5
CC1
F2 F1
F2
CC2
F2
F1 F2
CC1
F1
CC1
F1
CC1
CC1
CC2
F2
CC2
F2
F1
F3
F2
CC2
F2
F1F1
CC1
F2F2
FW
1
B1
B1
FW
1
B1
B1
FW2
FW2 FW2
FW2
B1B1
FW
1
FW
1
B1 B1
B1
B1
B1
B1
B1
FW
1F
W1
B1
B1
FW
2
B1
FW
1 FW
1
B1
B1B1
B1
RECESSED FLOOR GRATES
• SEE TYPICAL DETAILS
• REFER TO ARCH FOR EXTENTS
FW2: 300mm THICK
• 20M @ 200 V.I.F. + DWLS
• 15M @ 400 V.O.F. + DWLS
• 15M @ 400 H.E.F.
• ALL BARS TENSION LAP (CLASS 'B')
• HOOK HOR. AT WALL ENDS.CORNERS
FW1: 350mm THICK
• 20M @ 250 V.I.F. + DWLS
• 15M @ 250 V.O.F. + DWLS
• 20M @ 250 H.E.F.
• ALL BARS TENSION LAP (CLASS 'B')
• HOOK HOR. AT WALL ENDS.CORNERS
B1: REINFORCING BUNDLE:
• 6-30M @ 150 VERT. + DWLS
• 1-10M TIE @ 150 o.c.
PROVIDE SLAB THICKENING/FOOTING
AT BASE OF STAIRS TO SUIT
SUPPLIERS REQUIREMENTS
(ASSUME 600 W x 250 THICKENING
c/w: 4-15M BOT. LONG. FOR PRICING)
CC4
B1
COLUMN FOOTING
(SEE SCHEDULE FOR
REINFORCING TYP.)
S200
5
SIM.
S200
5
COLUMN FOOTING
(SEE SCHEDULE FOR
REINFORCING TYP.)
1500 DEEP
FOOTING U/N
1500 DEEP
FOOTING U/N
F3
S200
5
SIM.
S200
5
SIM.
FW
3
F3
F3
FW
3F
3
F3F3
F4F3
FW3
F4S200
2
F4
F4
S200
2
S200
2
F4
FW3
FW3
F4F3
F4
EX
TE
NS
ION
:
75
0 (
TY
P.)
F4
F4
S200
2
F4
S200
2
REFER TO ARCH. PLANS FOR MULLION
SUPPORT ANGLE LOCATIONS/EXTENTS
(TYP. ALL AREAS)
BTF
SCT5
SCT5
SCT5
PT3
BTF
PT3
BTF
PT3
BTFP
T3
FT6FT6
FT6
FT6
PROVIDE MIN. 2100 FROST
COVER TO LINK FOOTINGS /
FOOTINGS OF TOWER THAT
ARE IN PROXIMITY
F7
S200
1
INCREASE THICKNESS OF FT6
TO MATCH TOWER FOOTINGS
WHERE THEY COMBINE
FW3 (REFER TO SECTIONS)
BACKFILL BERMS WITH LIGHT
WEIGHT FILL/ENGINEERED
SOIL STABILIZATION AS PER
GEOTECHNICAL REPORT
(TYPICAL ALL LOCATIONS)
FOOTING STEP
(SEE SECTION)TOP OF F5 TO MATCH U/S OF
PIT/SUMP LOW POINT
(LOWER IF REQUIRED TO SUIT
GEOTECHNICAL REQUIREMENTS)
F5F6
TOP OF FOOTING TO BE -300
FROM U/S OF SLAB (MIN.)
- INCREASE CLEARANCE TO SUIT
MECH/ELECT. UNDER SLAB
REQUIREMENTS
- INCREASE DEPTH TO SUIT
GEOTECHNICAL REQUIREMENTS
S200
1
FOOTINGS AT CORE WALL "TIES" TO BE
-1500 FROM FINISHED T.O.C. SLAB TO
U/S OF FOOTING (INCREASE DEPTH TO
SUIT BEARING REQUIREMENTS)
13
25
13
25
1500 1500 1500 1500 1500 1500
1500 1500
13
25
13
25
RECESSED FLOOR GRATES
• SEE TYPICAL DETAILS
• REFER TO ARCH FOR EXTENTS
PROVIDE SLOPES TO DRAINS
AS PER ARCH/TYP. DETAILS
- COORDINATE SAWCUT
PATTERN IN THIS AREA WITH
ARCH.
PROVIDE SLOPES TO DRAINS AS
PER ARCH/TYP. DETAILS
- COORDINATE SAWCUT PATTERN
IN THIS AREA WITH ARCH.
SUMP PIT WALLS
(SEE TYP. DETAILS)
200
GENERAL NOTES:
1. ALL BEARING ELEVATIONS ARE TO BE CONFIRMED/COORDINATED WITH
GEOTECHNICAL REPORT/DATA. WHERE GEOTECHNICAL REPORT INDICATES
BEARING ELEVATIONS THAT ARE LOWER THAN THOSE PROVIDED,
GEOTECHNICAL REPORT VALUES GOVERN. CONTRACTOR IS RESPONSIBLE
FOR COORDINATION BETWEEN BOTH SETS OF DATA PROVIDED.
2. LOWER FTGS IN AREAS ADJACENT TO UNDERGROUND SERVICES/PITS AS
REQUIRED TO MAINTAIN MINIMUM 2H/1V ELEVATION OFFSET FOR BEARING
SURFACES (REFER TO S000) (TYP. ALL LOCATIONS).
3. ENGINEERED FILL/COMPACTED GRANULAR:
REFER TO GEOTECHNICAL REPORT FOR ALL REQUIREMENTS.
FOUNDATION / GROUND
FLOOR PLAN
1:100S100
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
RE
FE
R T
O D
RA
WIN
G S
T1
00
FO
R T
ES
T F
AC
ILIT
Y
![Page 10: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/10.jpg)
6950
H
J
30
M @
12
5 T
UL
40
00
25
M @
25
0 T
AD
D'L
30
M @
12
5 T
UL
T.L
.
30
M @
12
5 T
UL
30
M @
12
5 T
UL
15
00
15
00
30
M 6
00
0 @
125 T
UL
(2n
d L
AY
ER
AD
D'L
)
30
M 6
00
0 @
125 T
UL
(2n
d L
AY
ER
AD
D'L
)T
.L.30
M @
12
5 T
UL
25
M @
25
0 T
AD
D'L
30
M 5
00
0 @
125 B
LL
(2n
d &
3rd
LA
YE
RS
AD
D'L
)
(CE
NT
RE
D O
N G
RID
)
T.L
.3
0M
@ 1
25 B
LL
25
00
3-1
5M
ST
IRR
UP
S
@ 2
00
o.c
.
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
25
00
3-1
5M
ST
IRR
UP
S
@ 2
00
o.c
.
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
15
00
15
00
SLO
PE
FO
OT
ING
UP
30
M @
160 B
LL
30M @ 225 BUL
T.L.
2500
30M @ 225 BUL
15
00
15
00
30M 5500 @ 225 BUL
(2nd & 3rd LAYERS ADD'L)
25
M @
20
0 T
UL
30M @ 225 TLL
2500
30M 5500 @ 225 TLL
(1 LAYER ADD'L)
30
M @
125 B
LL
30M 5500 @ 225 BUL
(2nd & 3rd LAYERS ADD'L)
30
M @
125 B
LL
30
M @
125 B
LL
30
M 6
00
0 @
125 B
LL
(2n
d L
AY
ER
AD
D'L
)3
0M
60
00
@ 1
25 B
LL
(2n
d L
AY
ER
AD
D'L
)
25
M @
25
0 T
AD
D'L
30
M @
12
5 T
UL
T.L
.
12
00
30
M @
12
5 T
UL
30
M @
12
5 T
UL
15
00
15
00
30
M 6
00
0 @
125 T
UL
(2n
d L
AY
ER
AD
D'L
)
30
M 6
00
0 @
125 T
UL
(2n
d L
AY
ER
AD
D'L
)T
.L.
25
M @
25
0 T
AD
D'L
40
00
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
30
M 6
00
0 @
12
5 B
LL
(2nd L
AY
ER
AD
D'L
)3
0M
60
00
@ 1
25
BL
L (
2nd L
AY
ER
AD
D'L
)
30M 5000 @ 225 BUL
(2nd & 3rd LAYERS ADD'L)
30M 5000 @ 225 TLL
(1 LAYER ADD'L)
30M 5000 @ 225 BUL
(2nd & 3rd LAYERS ADD'L)
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
30M @ 225 TLL
30
M @
12
5 T
UL
35
M @
125 B
LL
25
M @
25
0 T
AD
D'L
30
M @
12
5 T
UL
T.L
.
15
00
30
M 5
00
0 @
150 T
UL
(2n
d L
AY
ER
AD
D'L
)
30
M 5
00
0 @
150 T
UL
(2n
d L
AY
ER
AD
D'L
)T
.L.
30
M @
12
5 T
UL
25
M @
25
0 T
AD
D'L
15
00
T.L
.
25
M @
25
0 T
AD
D'L
30
M @
12
5 T
UL
T.L
.3
0M
50
00
@ 1
50 T
UL
(2n
d &
3rd
LA
YE
R A
DD
'L)
30
M 5
00
0 @
150 T
UL
(2n
d L
AY
ER
AD
D'L
)T
.L.
30
M @
12
5 T
UL
25
M @
25
0 T
AD
D'L
T.L
.
30M @ 225 BUL
30
M @
125 B
LL
30
M 6
00
0 @
12
5 B
LL
(2nd L
AY
ER
AD
D'L
)3
0M
60
00
@ 1
25
BL
L (
2nd L
AY
ER
AD
D'L
)
40
00
40
00
15
00
15
00
15
00
15
00
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
3-1
5M
ST
IRR
UP
S
@ 3
00
o.c
.
SLO
PE
FO
OT
ING
UP
T.L
.
SLO
PE
FO
OT
ING
UP
30
M 5
00
0 @
125 B
LL
(2n
d &
3rd
LA
YE
RS
AD
D'L
)
(CE
NT
RE
D O
N G
RID
)
T.L
.
T.L
. T.L
.
T.L
.
SLO
PE
FO
OT
ING
UP
T.L
.
T.L
.
T.L
.T.L
.
30M 5500 @ 225 TLL
(1 LAYER ADD'L)
30M 5000 @ 225 TLL
(1 LAYER ADD'L)
600
400
2600
200
TUL (1st LAYER)
TUL (2nd LAYER)
TUL (3rd LAYER)
TLL (1st LAYER)
TLL (2nd LAYER)
TLL (3rd LAYER)
BLL (3rd LAYER)
BLL (2nd LAYER)
BLL (1st LAYER)
BUL (3rd LAYER)
BUL (2nd LAYER)
BUL (1st LAYER)
MIN
. 50
mm
CLE
AR
SP
AC
E (
TY
P)
BLL & TUL
BUL & TLL
TYPICAL REINFORCING LAYOUT
SHEAR WALL / CORE WALL
1:100S100R1
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
RE
FE
R T
O D
RA
WIN
G S
T1
00
FO
R T
ES
T F
AC
ILIT
Y
![Page 11: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/11.jpg)
SECOND FLOOR PLAN
SCALE: 1:100
15
00
1500
15
00
15
00
15
00
CB
2A
W410x46
W410x46
W
1
L 152x102x7.9 (LLH) ATPERIMETER
PROVIDE 25mm EXP. JOINT
(MIN.) BETWEEN EDGE OF
FLOOR SLABS/BRIDGE
PERIMETER ANGLE (TYP.)
PRE-ENG. STEEL STAIR
(REFER TO ARCH.)
CW2CW3
CW1
CONCRETE STAIR
(REFER TO DETAILS)
UPDN
UPDN
CONCRETE STAIR
(REFER TO DETAILS)
SLEEVING FOR PLUMBING/ELECT.
• REFER TO TYP. DETAILS FOR MIN.
SPACING/REINFORCING
• REFER TO MECH/ELECT. FOR
QUANTITY/SIZE
• TYPICAL ALL LOCATIONS
MOBILE STORAGE
AREA (L.L.= )
6950
H
J
S200
4
S200
2
S200
2
S200
3
35
0
35
0
35
0
400
400 400
35
03
50
400 400
8.6
kP
a
2.4
kP
a6
.8 k
Pa
8.6
kP
a
2.4
kP
a5
.6 k
Pa
70
0
600
70
0
600
DENOTES AREA WITH MAX.
300mm SOIL/STONE
550 CONC. SLAB
550 CONC. SLAB
CB
2B
W5
30x123
W530x123
W530x123
700 DP OWSJ @ 1000 o.c. (MAX.)
C20
0x17
AT
ED
GE
350 WIDE x 240 DEEP DROP BAND
c/w: - 2-15M T&B ADD'L LONG (CONTINUOUS)
- EXTEND 900mm PAST WALL AT EACH END
- 10M STIRRUPS @ 300 o.c.
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC1
CC2
CC1
CC1
CC1
CC1
CC2
CC2
CC2
CC1
50
0
50
05
00
50
0
30
0
30
0
U/S OF DROP PANELS IN
STORAGE AREA MATCHES U/S
IN REMAINING PART OF FLOORS
350
PUDDLE CONCRETE AT
CORE WALLS (SEE NOTE 5)
100mm INSULATION
BREAK (SEE ARCH.)
CC4
TOP OF RETAINING WALL
TO TIE INTO SLAB ABOVE
550 CONC. SLAB
1500
FW
1F
W1
FW2
FW2 FW2
FW2
FW
1
FW
1
FW
1F
W1
FW
2
FW
1 FW
1
S200
2
S200
3
200x750 HIGH CONC. CURB
• fc" = 25 MPa, N
• REINFORCING: SEE SECTIONS
S200
2
S200
2
S200
2
75
0
700
75
0
REFER TO ARCH. PLANS FOR MULLION
SUPPORT ANGLE LOCATIONS/EXTENTS
(TYP. ALL AREAS)
700
Cu=Tu=120 kN
SCT5
SCT5
SCT5
SCT5
W530x123
Cu=Tu=120 kN
SKEW BEAM AS REQ
TO FRAME ONTO
BEARING PLATE
FRAME INTO SIDE
OF GIRDER
500 DP OWSJ @ 1000 o.c. (MAX.)
Cu=Tu=120 kN
W530x123
Cu=Tu=120 kN
W530x123
Cu
=T
u=
150 k
NW5
30x123
Cu
=T
u=
150 k
N
C150x12 STUB EX
@ 1000 o.c. (MAX.
DENOTES FULL MOMENT/SHEAR
CONNECTION OF BEAM TO COLUMN
CANTILEVER JOIST SHOES
TO SUIT DECK EDGE
PROVIDE L 76x76x
2000 o.c. (MAX.) O
- CONNECT TO JO
- Cu=Tu=15 KN
- TYP. ALL BEAMS
FORCES NOTED
WALL CONTINUOUS
BELOW
WALL CONTINUOUS
BELOW
550 CONC. SLAB
100mm INSULATION GAP
(SLAB ONLY)
S201
9
700x750 DROP BAND
DROP PANEL SET BACK
@ 2nd FLOOR ONLY
700x750 DROP BAND
S201
9
8.3 KPa
9800A
2B
A2B
PARTITION SUPPORT GIRT (TYP. EACH FLOOR):
HSS 254x152x8.0 (LLV)
c/w: A 2B E.E.
- CONTRACTOR TO PROVIDE WEIGHTS OF ALL
PIPES/DUCTS/MECH. ELEMENTS TO BE
SUPPORTED ON BEAM (INCLUDING SUPPORT
DETAILS) PRIOR TO SHOP DRAWING SUBMITTAL
FOR GIRT (TYP. ALL FLOORS)
ELEVATOR SUPPORT/DIVIDER
BEAMS BY DIVISION 05 (INCLUDING
DESIGN/CERTIFICATION)
2SB1
2S
B2
A 2B: 300x300x16
c/w: 4-20mmØ ANCHORS
- PROVIDE 1-15M x900 LONG
ADD'L AT BEND IN ANCHOR/
BACK SIDE OF PLATE
300
50
100
100
100
PROVIDE SLOPES TO DRAINS
AS PER ARCH. LAYOUTS
(SEE TYP. DETAILS)
FOLDING PARTITION SCREEN SUPPORT
BEAM/BRACING
- CONTRACTOR TO SUBMIT SCREEN DATA
SHEETS FOR REVIEW PRIOR TO STEEL
FABRICATION/SHOP DRAWING SUBMITTAL
- SEE TYPICAL DETAILS FOR STEEL SUPPORT
C100x9 @ 1100 o.c.
(MAX.)
W
1 W
1
W
1
S201
10
S201
11
200
CB
2A
10
OUTLINE OF
2SB1/2SB2 IN SLAB
MAIN SLAB THICKNESS
AT 550mm TO EDGE
10
BLL
TUL
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 250
TOP(EXT.): CS: 20M 3300/6600 @ 250 (+ HOOK AT DISCONTINUOUS
ENDS) (EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M 130 @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 3-25M B + HOOK.
EXTERIOR CORNER: 4-20M B +HOOK
5. FLAT SLAB GEOMETRY U/N:
BUL
TLL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
2nd FLOOR: BRIDGE:
DEAD: 100 CONC./DECK: 2.00 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
STEEL: 0.25 kPa
2.85 kPa
LIVE: ASSEMBLY: 4.80 kPa
2nd FLOOR: MOBILE STORAGE:
DEAD: 300 CONC.: 7.20 kPa
190 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
PARTITION: 0.00 kPa (INCLUDED IN STORAGE LOAD)
9.45 kPa
LIVE: MOBILE STORAGE: kPa
2nd FLOOR: OFFICE:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 4200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF
CONCRETE AT COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL
ELEMENT. EXTEND PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
2nd FLOOR: LANDSCAPE:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa
300 SOIL: 6.00 kPa
14.85 kPa
LIVE: ROOF: 1.0 kPa
SNOW: 2.4 kPa (+ DRIFT)
550 CONC.: 13.20 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa
100 SOIL: 2.00 kPa
16.30 kPa
6. DESIGN LOADS
SECOND FLOOR PLAN
1:100S101
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTUREPERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURETENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
RE
FE
R T
O D
RA
WIN
G S
T1
01
FO
R T
ES
T F
AC
ILIT
Y
![Page 12: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/12.jpg)
SECOND FLOOR PLAN
SCALE: 1:100
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1 U
/N
22
50
M1 U
/N
2250 2250
CA
2250 2250 2250 2250
6950
H
J
35
0
35
0
35
0
400
400 400
35
03
50
400 400
30M @ 180 B
20M @ 250 T
2-20M T&B ADD'L
@ 180 AT EDGE
REBAR AS PER TYPICAL
LAYOUTS IS ADD'L TO
20M @ 250 T
REBAR AS PER TYPICAL
LAYOUTS IS ADD'L TO
20M @ 250 T
30M @ 180 B
20M @ 250 T
REBAR AS PER TYPICAL
LAYOUTS IS ADD'L TO
20M @ 250 T
REBAR AS PER TYPICAL
LAYOUTS IS ADD'L TO
20M @ 250 T
2-20M T&B ADD'L
@ 180 AT EDGE
C2 U
/N*
* REFER TO NOTE 9
C2*
20M @ 250
30M @ 180
FW
1F
W1
FW2
FW2 FW2
FW2
FW
1
FW
1
FW
1F
W1
FW
2
FW
1 FW
1
20M @ 250
30M @ 180
20M @ 250 T
15M @ 300 T
20M @ 250 T
20M @ 300 B
15M @ 200 B
20M @ 200 B
20M @ 200 T
*20M @ 200 B
20M @ 250 T
20M @ 300 B
20M @ 250 T
20M @ 250 T
*20M @ 200 B
20M @ 250 T
CLASS 'B' TENSION
LAP (TYP.)
15M @ 200 B
15M @ 300 T
20M @ 150 T
20M @ 200 T
*20M @ 200 B
20M @ 200 B
20M @ 250 T
20M @ 150 T
20M 3300 @ 250 T
20M 3300 @ 150 T
20M @ 150 T
20M @ 200 T20M @ 250 T
20M @ 200 B
20M @ 250 T
20M @ 250 T20M @ 250 T
20M @ 200 T20M @ 150 T
20M @ 200 B
20M @ 250 T
20M @ 300 B
20M @ 200 T
20M @ 300 B
20M @ 200 T
20M @ 300 B
1650/3300 (TYP.) 1650/3300 (TYP.) 1650/3300 (TYP.)
15M @ 250 T
15M @ 250 T15M @ 250 T
15M @ 200 B
15M @ 250 B15M @ 300 B
20M @ 200 T
20M @ 200 B
20M @ 250 T
20M @ 200 B20M @ 300 B
20M @ 175 T
20M @ 250 T 20M @ 200 T
NOTE:
* BOTTOM REINFORCING TO BE EXTENDEDFROM GRID E TO F @ 300mm SLAB
3300 (TYP.)
1650/3300 (TYP.)
3300 (TYP.)
3300 (TYP.)
15M @ 250 T
15M @ 200 B
20M @ 200 B
15M @ 250 T
3300 (TYP.)
1650/3300 (TYP.)
15M @ 200 B15M @ 250 B
15M @ 200 T
20M @ 200 B
20M @ 200 B
CLASS 'B'
TENSION LAP
(TYP)
20M @ 200 B
20M @ 250 T
20M @ 200 B
20M @ 200 B
20M @ 200 T20M @ 200 B
15M @ 250 T15M @ 250 B
20M @ 250 T
20M @ 250 T
15M @ 200 T
EXTEND TOP & BOTTOM
BARS INTO STAIRS (TYP)
(SEE SECTION)
HOOK BOTTOM BARS
AT CANTILEVER ENDS
(TYP.)
20M 6000/3000 @ 250 T
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
20M 6000/3000 @ 250 T
CLASS 'B' TENSIONS
LAP (TYP.)
20M 6000/3000 @ 250 T20M 6000/3000 @ 250 T
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
200
BLL
TUL
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 250
TOP(EXT.): CS: 20M 3300/6600 @ 250 (+ HOOK AT DISCONTINUOUS
ENDS) (EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M 130 @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 3-25M B + HOOK.
EXTERIOR CORNER: 4-20M B +HOOK
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
2nd FLOOR: BRIDGE:
DEAD: 100 CONC./DECK: 2.00 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
STEEL: 0.25 kPa
2.85 kPa
LIVE: ASSEMBLY: 4.80 kPa
2nd FLOOR: MOBILE STORAGE:
DEAD: 300 CONC.: 7.20 kPa
190 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
PARTITION: 0.00 kPa (INCLUDED IN STORAGE LOAD)
9.45 kPa
LIVE: MOBILE STORAGE: kPa
2nd FLOOR: OFFICE:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 4200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF
CONCRETE AT COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL
ELEMENT. EXTEND PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
2nd FLOOR: LANDSCAPE:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa
300 SOIL: 6.00 kPa
14.85 kPa
LIVE: ROOF: 1.0 kPa
SNOW: 2.4 kPa (+ DRIFT)
550 CONC.: 13.20 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa
100 SOIL: 2.00 kPa
16.30 kPa
6. DESIGN LOADS
SECOND FLOOR
(REINFORCING PLAN)
1:100S101R1
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTUREPERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURETENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
![Page 13: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/13.jpg)
SECOND FLOOR PLAN
SCALE: 1:100
CB
2A
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1 U
/N
22
50
M1 U
/N
2250 2250
CA
2250 2250 2250 2250
6950
H
J
35
0
35
0
35
0
400
400 400
35
03
50
400 400
20M
@ 2
50
B
20
M 1
50
0 @
250
20
M @
250
20
M 1
500
@ 2
50
20
M 1
500
@ 2
50
2-20M T&B ADD'L
@ 180 AT EDGE
20
M 1
50
0 @
250
2-20M T&B ADD'L
@ 180 AT EDGE
CB
2B
C2 U
/N*
* REFER TO NOTE 9
C2*
15M @ 200
15M @ 200
FW
1F
W1
FW2
FW2 FW2
FW2
FW
1
FW
1
FW
1F
W1
FW
2
FW
1 FW
1
15M @ 200
15M @ 200
20M
6000
@ 2
25 T
20M
@ 2
25 T
15M
@ 2
50 T
15M
@
250 T
20M
@ 1
80 T
20M
@ 2
50 T
20M
@ 1
80 T
16
50
/33
00 (
TY
P.)
20M
@ 2
00 T
20M
@ 2
00 T
20M
@ 2
30 T
20M
@ 2
00 T
20M
@ 2
00 T
20M
@ 2
75 T
20M
@ 2
75
20M
@ 2
25 T
20M
@ 2
50 T
15M
@ 3
00 B
15M
@ 2
50 T
20M
@ 2
25 T
20M
@ 2
25 T
32
50
(T
YP
.)
20M
@ 2
25 T
20M
@ 2
25 T
20M
@ 2
25 T
20M
@ 2
50 T
15M
@
250 B
15M
@ 3
00 B
15M
@ 2
50 T
15M
@ 2
50 T
15M
@ 2
50 T
20M
@ 2
25 T
16
50
/33
00 (
TY
P.)
20M
@ 2
75 T
15M
@ 2
50 T
20M
@ 2
25 T
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 B
33
00
(T
YP
.)
16
50
/33
00 (
TY
P.)
33
00
(T
YP
.)
20M
@ 2
75 T
15M
@ 2
50 B
15M
@ 2
50 B
20M
@ 2
25 T
33
00
(T
YP
.)
16
50
/33
00 (
TY
P.)
2SB1
2S
B2
20M
3300
@ 2
25 T
20M
@ 2
25 T
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 T
15M
@ 2
50 T
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P)20M
@ 2
50 B
20M
@ 2
50 B
33
00
18
00
/33
00
20M
@ 2
50 B
20M
@ 2
25 T
EXTEND TOP & BOTTOM
BARS INTO STAIRS (TYP)
(SEE SECTION)
20M
@ 2
25 T
20M
@ 3
00 B
20M
@
250 B
20M
@ 3
00 B
20M
@ 2
50 B
20M
@ 2
50 B
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
CL
AS
S 'B
' TE
NS
ION
LA
P (
TY
P.)
CL
AS
S'B
' T
EN
SIO
N
LA
P (
TY
P.)
HOOK BOTTOM BARS AT
CANTILEVER ENDS (TYP.)
20M
@ 2
50 B
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
4-20M @ 100 T&B
ADD'L AT OPENING
EDGE (EXTEND
1200 PAST FACE)
200
CB
2A
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 250
TOP(EXT.): CS: 20M 3300/6600 @ 250 (+ HOOK AT DISCONTINUOUS
ENDS) (EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M 130 @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 3-25M B + HOOK.
EXTERIOR CORNER: 4-20M B +HOOK
5. FLAT SLAB GEOMETRY U/N:
BUL
TLL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
2nd FLOOR: BRIDGE:
DEAD: 100 CONC./DECK: 2.00 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
STEEL: 0.25 kPa
2.85 kPa
LIVE: ASSEMBLY: 4.80 kPa
2nd FLOOR: MOBILE STORAGE:
DEAD: 300 CONC.: 7.20 kPa
190 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
PARTITION: 0.00 kPa (INCLUDED IN STORAGE LOAD)
9.45 kPa
LIVE: MOBILE STORAGE: kPa
2nd FLOOR: OFFICE:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 4200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF
CONCRETE AT COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL
ELEMENT. EXTEND PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
2nd FLOOR: LANDSCAPE:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa
300 SOIL: 6.00 kPa
14.85 kPa
LIVE: ROOF: 1.0 kPa
SNOW: 2.4 kPa (+ DRIFT)
550 CONC.: 13.20 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa
100 SOIL: 2.00 kPa
16.30 kPa
6. DESIGN LOADS
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
SECOND FLOOR
(REINFORCING PLAN)
1:100S101R2
![Page 14: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/14.jpg)
THIRD FLOOR PLAN
SCALE: 1:100
CB
3A
CB
3B
L 152x102x7.9 (LLH)
AT PERIMETER
HSS 305 GIRT
NEOPRENE BEARING PADS
FOR W410 (SEE DETAILS) (TYP)
PROVIDE 28mm EXP. JOINT
(MIN.) BETWEEN EDGE OF
FLOOR SLABS/BRIDGE
PERIMETER ANGLE (TYP.)
A3B A
3B
CONCRETE STAIR
(REFER TO DETAILS)
CONCRETE STAIR
(REFER TO DETAILS)
SLEEVING FOR PLUMBING/ELECT.
• REFER TO TYP. DETAILS FOR MIN.
SPACING/REINFORCING
• REFER TO MECH/ELECT. FOR
QUANTITY/SIZE
• TYPICAL ALL LOCATIONS
15
00
1500
15
00
15
00
15
00
CW2CW3CW1
UPDN
UPDN
35
0
35
0
35
03
50
1500
A3B
A3B
W410x46
W410x46
W
1
W
1
PRE-ENG. STEEL STAIR
(REFER TO ARCH.)
A3B
A3B
A3B
A3B
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC1
CC2
CC1
CC1
CC1
CC1
CC2
CC2
CC2
CC1
400 400
400 400
350
PUDDLE CONCRETE AT
CORE WALLS (SEE NOTE 5)
CC4
15
00
1500
15
00
SEE DETAILS/SECTION
FOR A 3B
S201
7
S201
5
S201
5
S201
7
SEE SECTIONS/DETAILS
FOR ADD'L REBAR AT
GIRT ANCHOR PLATES
S200
6
S200
7
S200
8
S200
8
TYP.
REFER TO ARCH. PLANS FOR MULLION
SUPPORT ANGLE LOCATIONS/EXTENTS
(TYP. ALL AREAS)
HSS 305 GIRT
HSS 305 GIRT
S201
6
TYP.
HSS 305 GIRTTYP.
S200
8
S200
8
ELEVATOR SUPPORT/DIVIDER
BEAMS BY DIVISION 05 (INCLUDING
DESIGN/CERTIFICATION)
PROVIDE SLOPES TO DRAINS
AS PER ARCH. LAYOUTS
(SEE TYP. DETAILS)
A3C
A3C
PARTITION SUPPORT GIRT (TYP. EACH FLOOR):
HSS 254x152x8.0 (LLV)
c/w: A 2B E.E.
- CONTRACTOR TO PROVIDE WEIGHTS OF ALL
PIPES/DUCTS/MECH. ELEMENTS TO BE
SUPPORTED ON BEAM (INCLUDING SUPPORT
DETAILS) PRIOR TO SHOP DRAWING SUBMITTAL
FOR GIRT (TYP. ALL FLOORS)
A 3C: 300x300x16
c/w: 4-20mmØ ANCHORS
- PROVIDE 1-15M x900 LONG
ADD'L AT BEND IN ANCHOR/
BACK SIDE OF PLATE
300
50
100
100
100
PROVIDE SLOPES TO DRAINS
AS PER ARCH. LAYOUTS
(SEE TYP. DETAILS)
49
02
10
C100x9 @ 1100
o.c. (MAX.)
S201
10
S201
11
W
1
W
1
200
400
1500
35
0
CB
3A
BLL
TUL
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
BUL
TLL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 8200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF CONCRETE AT
COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL ELEMENT. EXTEND
PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
6. DESIGN LOADS
3rd FLOOR:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
BRIDGE:
DEAD: 100 CONC./DECK: 2.00 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
STEEL: 0.25 kPa
2.85 kPa
LIVE: ASSEMBLY: 4.80 kPa
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 250
TOP(EXT.): CS: 20M 3300/6600 @ 250 (+ HOOK AT DISCONTINUOUS
ENDS) (EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M 130 @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 3-25M B + HOOK.
EXTERIOR CORNER: 4-20M B +HOOK
THIRD FLOOR PLAN
1:100S102
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
![Page 15: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/15.jpg)
THIRD FLOOR PLAN
SCALE: 1:100
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1 U
/NC
2 U
/N*
22
50
M1 U
/N
2250 2250
CA
2250 2250 2250 2250
* REFER TO NOTE 9
C2*
20M @ 200 T
20M @ 250 B
20M @ 250 T
20M @ 250 B
20M @ 250 T
20M @ 250 B
20M @ 250 T
15M @ 250 B15M @ 250 B15M @ 250 B
15M @ 300 T15M @ 225 T15M @ 300 T 15M @ 250 T
20M @ 200 T20M @ 250 B
20M @ 200 B20M @ 200 B
20M @ 200 T20M @ 250 T20M @250 T
20M @ 200 T
15M 3300 @ 225 T
20M @ 250 T 20M @ 200 T
15M @ 250 T15M @ 225 T
20M @ 250 T
20M @ 200 B
20M @ 250 B20M @ 250 B
20M 1650/3300 @ 250 T20M @ 250 T20M @ 200 T
3000 (TYP.) 1650/3300 (TYP.) 1650/3300 (TYP.)
15M @ 250 B15M @ 250 B
15M 3300 @ 250 T15M @ 225 T15M @ 300 T
20M @ 200 B20M @ 250 B
20M 1650/3300 @ 250 T20M @ 200 T
20M @ 200 B
20M @ 250 T20M @ 200 T20M @ 200 T
15M @ 225 T
1500/3000 (TYP.)
3000 (TYP.)
15M @ 250 T
3300 (TYP.)
1650/3300 (TYP.)
15M @ 250 B20M @ 250 B20M @ 250 B
15M @ 250 T15M @ 250 T
15M @ 250 B
CLASS 'B'
TENSION LAP
(TYP.)
CLASS 'B'
TENSION LAP
(TYP.)
CLASS 'B'
TENSION LAP
(TYP.)
3300 (TYP.)
CLASS 'B'
TENSION LAP
(TYP.)
20M @ 200 B
20M @ 250 B
20M @ 200 T20M @ 250 T
20M @ 200 B
20M @ 200 B
20M 3300 @ 200 T20M @ 250 T
20M @ 200 B
SEE RS1C / TYPICAL DETAILS FOR
SHORT BAR/LONG BAR BOTTOMSTEEL LENGTHS WHERE SLAB IS
CONTINUOUS AT GRIDS E / F / B
20M @ 250 B
15M @ 250 B
20M @ 250 B
20M @ 200 T
20M @ 250 T
20M @ 200 B
15M @ 250 T
15M @ 250 B
20M @ 200 T
CLASS 'B'
TENSION LAP
(TYP.)
15M @ 250 B
CLASS 'B'
TENSION LAP
(TYP.)
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
HOOK BOTTOM BARS
AT CANTILEVER ENDS
(TYP.)
20M @ 250 B
15M @ 250 B
20M @ 250 B
15M @ 250 B200
EXTEND TOP & BOTTOM
BARS INTO STAIRS (TYP)
(SEE SECTION)
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M 3300/6600 @ 250
TOP(EXT.): CS: 20M @ 250 (+ HOOK AT DISCONTINUOUS ENDS)
(EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 4-25M B.
EXTERIOR COLUMN: 3-20M B. + HOOK.
EXTERIOR CORNER: 3-20M B +HOOK
BLL
TUL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 8200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF CONCRETE AT
COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL ELEMENT. EXTEND
PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
6. DESIGN LOADS
3rd FLOOR:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
BRIDGE:
DEAD: 100 CONC./DECK: 2.00 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
STEEL: 0.25 kPa
2.85 kPa
LIVE: ASSEMBLY: 4.80 kPa
1:100S102R1
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
THIRD FLOOR PLAN(TYPICAL REINFORCING U/N)
![Page 16: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/16.jpg)
THIRD FLOOR PLAN
SCALE: 1:100
CB
3A
CB
3B
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1 U
/NC
2 U
/N*
22
50
M1 U
/N
2250 2250
CA
2250 2250 2250 2250
* REFER TO NOTE 9
C2*
20M
@ 1
50 T
20M
@ 2
00 T
15M
@ 3
00 T
33
00
(T
YP
.)
20M
@ 2
00 T
20M
@ 2
50 T
20M
@ 2
75 B
20M
@ 2
00 T
20M
@ 2
50 B
15M
@ 2
50 B
20M
@ 3
00 T
18
00
/33
00 (
TY
P.)
20M
@ 3
00 T
CL
AS
S 'B
' TE
NS
ION
LA
P (
TY
P.)
15M
@ 2
50 B
20M
@ 2
00 T
20M
@ 2
50 B
20M
@ 2
00 T
20M
@ 2
00 T
20M
@ 2
75 B
20M
@ 1
50 T
20M
@ 2
00 T
15M
@ 3
00 T
20M
@ 2
00 T
20M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 T
15M
@ 2
50 T
20M
@ 2
50 T
20M
@
250 T
20M
@ 2
00 T
20M
@ 2
00 T
20M
3300
@ 2
00 T
20M
@ 2
00 T
20M
3300
@ 2
50 T
20M
3300
@ 2
50 T
20M
3300
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
33
00
18
00
/33
00
33
00
33
00
33
00
18
00
/33
00
15M
@ 2
50 B
15M
@ 2
50 B
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P)20M
@ 2
50 B
20M
@ 2
50 B
BEND TOP/BOT.
BARS INTO STAIR
(SEE SECTION)
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
20M @ 200 T&B ADD'L
4-20M @ 100 T&B
ADD'L AT OPENING
EDGE (EXTEND
1200 PAST FACE)
20M
@ 2
50 T
20M
@ 2
75 B
20M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 B
20M
@ 2
50 B
20M
@ 2
75 B
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
3300
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
33
00
(T
YP
.)C
LA
SS
'B
' TE
NS
ION
LA
P (
TY
P.)
BEND TOP/BOT.
BARS INTO STAIR
(SEE SECTION)
HOOK BOTTOM BARS
AT CANTILEVER ENDS
(TYP.)
20M
@ 2
50 B
CB
3A
200
EXTEND TOP & BOTTOM
BARS INTO STAIRS (TYP)
(SEE SECTION)
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 8200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF CONCRETE AT
COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL ELEMENT. EXTEND
PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
6. DESIGN LOADS
3rd FLOOR:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
BRIDGE:
DEAD: 100 CONC./DECK: 2.00 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
STEEL: 0.25 kPa 2.85 kPa
LIVE: ASSEMBLY: 4.80 kPa
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M 3300/6600 @ 250
TOP(EXT.): CS: 20M @ 250 (+ HOOK AT DISCONTINUOUS ENDS)
(EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 4-25M B.
EXTERIOR COLUMN: 3-20M B. + HOOK.
EXTERIOR CORNER: 3-20M B +HOOK
BUL
TLL
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
1:100S102R2
THIRD FLOOR PLAN(TYPICAL REINFORCING U/N)
![Page 17: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/17.jpg)
FOURTH FLOOR PLAN
SCALE: 1:100
CONCRETE STAIR
(REFER TO DETAILS)
CONCRETE STAIR
(REFER TO DETAILS)
SLEEVING FOR PLUMBING/ELECT.
• REFER TO TYP. DETAILS FOR MIN.
SPACING/REINFORCING
• REFER TO MECH/ELECT. FOR
QUANTITY/SIZE
• TYPICAL ALL LOCATIONS
15
00
1500
15
00
15
00
15
00
CW2 CW3CW1
UPDN
UPDN
35
0
35
0
35
03
50
1500
PRE-ENG. STEEL STAIR
(REFER TO ARCH.)
50
05
00
300 SLAB
500
(TYP)
CC2
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC1
CC2
CC1
CC1
CC1
CC1
CC2
CC2
CC1
4S
B1
4S
B1
4S
B1
4S
B1
400 400
400 400
350
CC4
PROVIDE VERTICAL SUPPORT
FOR CURTAIN WALL AT 4th
FLOOR (REFER TO ARCH.)
ELEVATOR SUPPORT/DIVIDER
BEAMS BY DIVISION 05 (INCLUDING
DESIGN/CERTIFICATION)
PROVIDE SLOPES TO DRAINS
AS PER ARCH. LAYOUTS
(SEE TYP. DETAILS)
PROVIDE SLOPES TO DRAINS
AS PER ARCH. LAYOUTS
(SEE TYP. DETAILS)
200
35
0
400
CB
4A
BLL
TUL
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 250
TOP(EXT.): CS: 20M 3300/6600 @ 250 (+ HOOK AT DISCONTINUOUS
ENDS) (EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M 130 @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 3-25M B + HOOK.
EXTERIOR CORNER: 4-20M B +HOOK
BUL
TLL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 12,200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF
CONCRETE AT COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL
ELEMENT. EXTEND PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
6. DESIGN LOADS
4th FLOOR:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
300 CONC.: 7.20 kPa
240 DROP: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
10.45 kPa
FOURTH FLOOR PLAN
1:100S103
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
![Page 18: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/18.jpg)
FOURTH FLOOR PLAN
SCALE: 1:100
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1
U/N
22
50
M1
U/N
2250 2250
CA
2250 2250 2250 22502700 2700
C2
U/N
*
* REFER TO NOTE 9
C2*
20M @ 200 T
15M @ 300 T
20M @ 175 T
20M @ 250 B
20M 5000/8000 @ 175 T
20M @ 250 B20M @ 250 B*20M @ 225 B20M @ 250 B20M @ 250 B
20M @ 200 T20M @ 200 T20M @ 200 T
20M @ 200 T20M @ 200 T
2500/40002500/4000
CLASS 'B' TENSION
LAP (TYP.)
15M @ 250 B15M @ 200 B15M @ 250 B*20M @ 225 B15M @ 250 B15M @ 250 B
20M 8000 @ 250 T15M @ 250 T20M @ 250 T20M @ 250 T15M @ 250 T15M @ 300 T
4000 4000
20M @ 250 B20M @ 200 B20M @ 255 B*20M @ 250 B20M @ 225 B20M @ 250 B20M 6000 @ 175 T20M @ 175 T
20M @ 175 T20M @ 175 T20M @ 175 T20M @ 175 T
2000/40002500/40002500/40001650/3300 (TYP.)3300 (TYP.)
20M @ 175 T20M @ 175 T20M @ 175 T
20M @ 250 T20M @ 200 B
15M @ 200 T15M @ 200 T
2500/400020M @ 175 T20M @ 175 T
20M @ 175 T
20M @ 175 T
NOTE:
* BOTTOM REINFORCING TO BE EXTENDED
FROM GRID TO GRID @ 300mm SLAB
4000
2500/4000
15M @ 250 B
15M @ 250 T
15M@ 250 T
20M @ 250 B20M@ 250 T
20M @ 250 B
15M@ 250 T15M@ 250 T
15M @ 250 B
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
CLASS 'B'
TENSION LAP
(TYP.)
CLASS 'B'
TENSION LAP
(TYP.)
20M @ 250 B
15M @ 250 B
CLASS 'B'
TENSION LAP
(TYP.)
20M @ 250 B
15M @ 250 B
4000
4000
20M @ 200 B
20M 3300 @ 175 T20M 3300 @ 175 T20M @ 175 T
CLASS 'B' TENSION
LAP (TYP.)
CLASS 'B' TENSION
LAP (TYP.)
20M @ 200 B
20M @ 225 B
20M @ 175 T
20M @ 225 B
20M @ 175 T
20M @ 250 B
20M @ 175 T
20M @ 250 B20M @ 225 B
CLASS 'B' TENSION
LAP (TYP.)
20M @ 175 T20M @ 250 T20M @ 250 B
20M @ 175 T
33003300 (TYP)
20M @ 250 B
15M @ 250 B
20M @ 250 B
15M @ 250 B
SEE RS1C / TYPICAL DETAILS FOR
SHORT BAR/LONG BAR BOTTOMSTEEL LENGTHS WHERE SLAB IS
CONTINUOUS AT GRIDS E / F / B
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
HOOK BOTTOM BARS
AT CANTILEVER ENDS
(TYP.)
20M @ 200 T
20M @ 250 T
20M @ 175 T
CLASS'B' TENSION
LAP (TYP.)
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
200
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 250 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M 3300/6600 @ 250
TOP(EXT.): CS: 20M @ 250 (+ HOOK AT DISCONTINUOUS ENDS)
(EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M @ 300 (+ HOOK AT DISCONTINUOUS EDGE) (6600
LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 4-25M B. + HOOK.
EXTERIOR CORNER: 4-25M B +HOOK
BLL
TUL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 12,200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF
CONCRETE AT COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL
ELEMENT. EXTEND PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
6. DESIGN LOADS
4th FLOOR:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
300 CONC.: 7.20 kPa
240 DROP: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
10.45 kPa
1:100S103R1
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
FOURTH FLOOR
(REINFORCING PLAN)
![Page 19: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/19.jpg)
FOURTH FLOOR PLAN
SCALE: 1:100
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1 U
/N
22
50
M1 U
/N
2250 2250
CA
2250 2250 2250 22502700 2700
C2 U
/N*
* REFER TO NOTE 9
C2*
20M
@ 2
25 T
20M
@ 2
25 T 18
00
/33
00 (
TY
P.)
20M
@ 2
25 T
20M
@ 2
25 T
15M
@ 2
50 T
15M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 3
00 T
20M
@ 1
75 T
15M
@ 3
00 T
33
00
(T
YP
.)
20M
@ 3
00 T
20M
@ 3
00 T
33
00
(T
YP
.)
20M
@ 2
50 T
20M
@ 1
75 T
15M
@ 2
50 T
15M
@ 3
00 T
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 T
33
00
(T
YP
.)
20M
@ 2
50 B
20M
@
250 B
20M
@ 2
50 T
20M
@ 2
50 B
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
25 B
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
20M
@ 2
25 B
20M
@ 3
00 T
BEND TOP/BOT.
BARS INTO STAIR
(SEE SECTION)
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
BEND TOP/BOT.
BARS INTO STAIR
(SEE SECTION)
EXTEND ALL BOTTOM
BARS INTO STAIR (TYP)
HOOK BOTTOM BARS
AT CANTILEVER ENDS
(TYP.)
20M
@ 2
25 B
20M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 B
20M
@ 2
50 B
20M
@ 2
25 B
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
33
00
(T
YP
.)
20M
@ 2
50 B
20M
@ 2
50 B
15M
@ 2
50 T
15M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
20M
@ 2
50 T
18
00
/33
00 (
TY
P.)
33
00
(T
YP
.)
18
00
/33
00 (
TY
P.)
33
00
(T
YP
.)
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
CL
AS
S'B
' T
EN
SIO
N
LA
P (
TY
P.)
CL
AS
S'B
' T
EN
SIO
N
LA
P (
TY
P.)
20M
@ 2
50 B
20M
@ 2
50 B
33
00
(T
YP
.)
33
00
(T
YP
.)
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 B
15M
@ 2
50 T
18
00
/33
00 (
TY
P.)
15M
@ 2
50 T
20M
@ 2
50 B
20M
@ 2
50 B
20M
@ 2
50 B
20M
@ 2
50 B
20M
@ 2
50 T
20M
@ 2
50 T
CL
AS
S'B
' T
EN
SIO
N
LA
P (
TY
P.)
20M
@ 3
00 T
20M
@ 3
00 T
20M
@
250 B
20M
@ 2
50 B
18
00
/33
00 (
TY
P.)
15M
@ 2
50 B
15M
@ 2
50 B
33
00
(T
YP
)
20M
@ 2
50 B
20M
@ 2
50 B
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
4-20M @ 100 T&B
ADD'L AT OPENING
EDGE (EXTEND
1200 PAST FACE)
200
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 250 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M 3300/6600 @ 250
TOP(EXT.): CS: 20M @ 250 (+ HOOK AT DISCONTINUOUS ENDS)
(EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M @ 300 (+ HOOK AT DISCONTINUOUS EDGE) (6600
LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 4-25M B. + HOOK.
EXTERIOR CORNER: 4-25M B +HOOK
BUL
TLL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
5. FLAT SLAB GEOMETRY U/N:
SLAB: 250 THICK
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: 12,200
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF
CONCRETE AT COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL
ELEMENT. EXTEND PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
6. DESIGN LOADS
4th FLOOR:
DEAD: 250 CONC.: 6.10 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
9.35 kPa
LIVE: OFFICE: 3.80 kPa
EXITS: 4.80 kPa
300 CONC.: 7.20 kPa
240 DROP: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
PARTITION: 1.00 kPa
FLOORING: 0.10 kPa
10.45 kPa
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
1:100S103R2
FOURTH FLOOR
(REINFORCING PLAN)
![Page 20: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/20.jpg)
ROOF PLAN
SCALE: 1:100
SC1
CW3CW1
15
00
1500
15
00
CONCRETE STAIR
(REFER TO DETAILS)
CONCRETE STAIR
(REFER TO DETAILS)
15
00
15
00
DN
DN
6.6
KP
a
70
00
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
H.P
.(0)
SC1S
C1
SC1
SC1
SC1
SC1
SC1
H.P
.(0)
H.P
.(0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
50
300mm/450mm SLAB
500
(TYP)
RS
B2
RS
B2
RS
B2
RS
B2
35
0
35
0
400 400
35
03
50
35
0
400
400 400
35
0
200x700 CONC. CURB
(REFER TO SECTION FOR
REINFORCING)
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2
S201
4
S201
4
S201
4
B5C
(TYP)
B 5C: MECH. SCREEN B
350x350x40
c/w: 4-25mmØ HEADED ANCHORS
- WASHER PLATE: 76x76x16
c/w: NUT ON BOTTOM (TACK
WELD TO BOLT)
- STAINLESS STEEL ANCHORS
21
0
ALL STEEL IN SCREEN FRAMING
TO BE HOT DIPPED GALV.
• FABRICATE FRAME TO
MITIGATED SITE WELDING
• ALL BOLTS TO BE STAINLESS
STEEL
SCREEN HORIZONTALS:
HSS 203x102x9.5 (SEE SECTION)
WHERE ROOF ANCHORS ARE REQUIRED
PROVIDE ADD'L REINFORCING STEEL TO
SUIT SUPPLIERS REQUIREMENTS
• SUBMIT ROOF ANCHOR SHOP DRAWING
WITH REBAR SHOP DRAWINGS
• PROVIDE MIN. 2-20M 1800 T&B E.W. AT
ANCHORS
B 5A: TYP. PENTHOUSE COLUMN B350x350x20
c/w: 4-16mmØ ANCHORS
B5A
B5A
B5A B
5A
B5A
B5A
B5B
B5B
RSB1
RSB1
200
50
B 5B: PENTHOUSE
EXTERIOR COLUMN B
350x152x20
c/w: 4-12mmØ ANCHORS
200
S201
2
S201
2
S201
8
S201
8
S201
8
REFER TO ARCH. PLANS FOR
PARAPET SUPPORT FRAMING
LOCATIONS/EXTENTS
(TYP. ALL AREAS)
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC2
CC2
CC1
CC1
CC1
CC2
CC1
CC1
CC1
CC1
CC2
CC2
CC2
CC1
CC4
ELEVATOR SUPPORT/DIVIDER
BEAMS BY DIVISION 05 (INCLUDING
DESIGN/CERTIFICATION)
S201
8
PROVIDE HOIST BEAM/HOIST TO OWNER'S
SPECIFICATIONS AT U/S OF STAIR ROOF FRAMING
- TYPICAL EACH STAIR
- DESIGN/DETAILING/CERTIFICATION BY DIVISION 05
MAX. 100mm THICK MECH. PADS
SUPPORTED ON JACK-UP
ISOLATION PADS. BELOW ALL
MECH. UNITS
- REFER TO MECH. FOR EXTENTS
- DESIGN/DETAILING OF PADS AS
PER MECH. CONTRACTOR'S
REQUIREMENTS
35
0
PROVIDE MAX. 100mm PADS BELOW EQUIPMENT
- REFER TO MECH./ARCH. FOR EXTENTS
- REFER TO TYP. DETAILS FOR PAD REINFORCING
150mm HIGH x 150mm WIDE CONC. CURBS @ ISOLATION PADS.
c/w: - 10M @ 200 VERTS.
- 2-15M HORIZ. @ TOP
- HOOK VERTS. 90° INTO SLAB @ BOT. (NORMAL DWL)
- HOOK VERTS. 90° INTO CURB @ TOP
(100mm BEND)
200
PARTIAL PLAN: ELEVATOR OVERRUN
SCALE: 1:100
250mm CONC. SLAB
20M @ 300 TUL
20M @ 300 TLL
15M
@ 3
00
BU
L
15M 1800 @ 300 TLL (E.E.)
5. FLAT SLAB GEOMETRY U/N:
SLAB: 425 MAX./275 MIN. THICK - 450 MAX/300 MIN.
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: P.H. FLOOR: 16,200
T.O.C. EL.: ROOF: 16,200 (LOW POINT)
T.O.C. EL.: ROOF: 16,350 (HIGH POINT)
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF CONCRETE AT
COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL ELEMENT. EXTEND
PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
PROVIDE VARYING HEIGHT CHAIRS TO TOP STEEL TO MAINTAIN 25mm CLEAR COVER FROM
TOP OF SLOPING SLAB.
REFER TO LEVEL 3 REINFORCING U/N.
6. DESIGN LOADS
ROOF AREAS: CONCRETE SLAB:
DEAD: 425 MAX/275 MIN. CONC.: 9.00 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa (CONVENTIONAL)
11.75 kPa
LIVE: ROOF: 1.00 kPa
SNOW: 2.40 kPa (+ DRIFT)
BLL
TUL
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 250 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 300 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 250
TOP(EXT.): CS: 20M 3300/6600 @ 250 (+ HOOK AT DISCONTINUOUS
ENDS) (EXTEND 3300 INTO CONTINUOUS SIDE)
MS: 15M 130 @ 300 (+ HOOK AT DISCONTINUOUS EDGE)
(6600 LONG @ EXTERIOR EDGES EXTEND 3300 INTO
CONTINUOUS SIDE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 3-25M B.E.W.
EXTERIOR COLUMN: 3-25M B + HOOK.
EXTERIOR CORNER: 4-20M B +HOOK
BUL
TLL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
MECH. AREAS: CONCRETE SLAB:
DEAD: 275 CONC.: 6.60 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
8.85 kPa
LIVE: MECH. ROOM: 7.20 kPa (INCL. 100mm EQUIP/PADS)
ELEVATOR OVERRUN:
DEAD: 200 CONC.: 4.80 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
5.40 kPa
LIVE: MECH. ROOM: 7.20 kPa (INCL. 100mm EQUIP/PADS)
ROOF PLAN
1:100S104
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
![Page 21: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/21.jpg)
PARTIAL PLAN: ELEVATOR OVERRUN
SCALE: 1:100
15M @ 350 TUL/BLL
15M @ 350 TLL/BUL
250mm CONC. SLAB
200mm CONC. SLAB
20M @ 300 TUL
20M @ 300 TLL
15M
@ 3
00
BU
L
15M 1800 @ 300 TLL (E.E.)
5. FLAT SLAB GEOMETRY U/N:
SLAB: 425 MAX./275 MIN. THICK - 450 MAX/300 MIN.
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: P.H. FLOOR: 16,200
T.O.C. EL.: ROOF: 16,200 (LOW POINT)
T.O.C. EL.: ROOF: 16,350 (HIGH POINT)
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF CONCRETE AT
COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL ELEMENT. EXTEND
PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
PROVIDE VARYING HEIGHT CHAIRS TO TOP STEEL TO MAINTAIN 25mm CLEAR COVER FROM
TOP OF SLOPING SLAB.
REFER TO LEVEL 3 REINFORCING U/N.
6. DESIGN LOADS
ROOF AREAS: CONCRETE SLAB:
DEAD: 425 MAX/275 MIN. CONC.: 9.00 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa (CONVENTIONAL)
11.75 kPa
LIVE: ROOF: 1.00 kPa
SNOW: 2.40 kPa (+ DRIFT)
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 200 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 200 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 200
TOP(EXT.): CS: 20M @ 250 (+ HOOK AT DISCONTINUOUS ENDS)
MS: 15M @ 250 (+ HOOK AT DISCONTINUOUS EDGE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 4-25M B.E.W.
EXTERIOR COLUMN: 4-25M B + HOOK
EXTERIOR CORNER: 4-25M B +HOOK
BLL
TUL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
MECH. AREAS: CONCRETE SLAB:
DEAD: 275 CONC.: 6.60 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
8.85 kPa
LIVE: MECH. ROOM: 7.20 kPa (INCL. 100mm EQUIP/PADS)
ELEVATOR OVERRUN:
DEAD: 200 CONC.: 4.80 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
5.40 kPa
LIVE: MECH. ROOM: 7.20 kPa (INCL. 100mm EQUIP/PADS)
ROOF PLAN
SCALE: 1:100
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1
U/N
22
50
M1
U/N
2250 2250
CA
2250 2250 2250 22502700 2700
* REFER TO NOTE 9
300mm/450mm SLAB
500
(TYP)
RS
B2
RS
B2
RS
B2
RS
B2
RSB1
RSB1
REFER ALSO TO 8/S201
FOR ADD'L 15M CONT.
AT SLAB EDGE
20M @ 250 T
20M @ 250 B
15M @ 225 T
20M @ 200 T
20M @ 225 T
3300 (TYP.)
20M 3500/7000 @ 250 T20M @ 250 T20M @ 200 T
20M @ 200 T20M @ 250 T
20M @ 250 T
20M @ 250 B20M @ 250 B20M @ 250 B *20M @ 250 B
20M @ 250 B
15M @ 200 B15M @ 200 B15M @ 200 B15M @ 250 B *15M @ 200 B15M @ 250 B
15M 7000 @ 225 T15M @ 225 T15M @ 225 T
15M @ 225 T15M @ 225 T
15M @ 225 T
40004000
20M @ 250 B20M @ 200 B20M @ 250 B20M @ 225 B *20M @ 250 B20M @ 200 B20M @ 175 T20M @ 200 T20M @ 175 T20M @ 175 T
20M @ 200 T20M @ 200 T
CLASS'B' TENSION
LAP (TYP.)
2500/40002500/40001650/3300 (TYP.)3300 (TYP.)
20M @ 175 T
20M @ 250 B
20M 3500 @ 225 T
20M @ 175 T20M @ 200 T
20M @ 250 B
20M @ 225 T20M @ 225 T
20M @ 250 B
20M @ 225 T20M @ 225 T
20M @ 225 T20M @ 225 T
20M @ 200 B
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
SEE RS1C / TYPICAL DETAILS FOR
SHORT BAR/LONG BAR BOTTOMSTEEL LENGTHS WHERE SLAB IS
CONTINUOUS AT GRIDS E / F / B
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
20M @ 250 B
15M @ 200 B
20M @ 250 B
15M @ 250 B
20M @ 250 B
15M @ 250 B
20M @ 250 B
20M @ 200 B
HOOK BOTTOM BARS
AT CANTILEVER ENDS
(TYP.)
CLASS 'B'
TENSION LAP
(TYP.)
CLASS 'B'
TENSION LAP
(TYP.)
C2
U/N
*C
2*
2500/4000 2500/4000
CLASS 'B' TENSION
LAP (TYP.)2500/4000 2500/4000
CLASS 'B'
TENSION LAP
(TYP.)
4000
CLASS 'B'
TENSION LAP
(TYP.)
20M @ 175 T
20M @ 200 T
20M 3300 @ 175 T20M @ 175 T
20M @ 225 B
20M @ 175 T
20M @ 225 B
20M @ 250 T
20M @ 250 B
4000
20M @ 225 B20M @ 175 T
4000
20M @ 225 B
20M @ 225 B
20M @ 225 B
20M @ 175 T
CLASS 'B'
TENSION LAP (TYP.)
CLASS 'B'
TENSION LAP (TYP.)
20M @ 175 T 20M @ 175 T
CLASS 'B'
TENSION LAP (TYP.)
20M @ 200 T
20M @ 200 B
20M @ 175 TCLASS 'B'
TENSION LAP (TYP.)
20M @ 175 T
20M @ 200 B
20M @ 200 T
NOTE:* BOTTOM REINFORCING TO BE EXTENDED
FROM EDGE TO EDGE @ 300mm/450mm SLAB
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
20M @ 250 B
1:100S104R1
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
ROOF
(REINFORCING PLAN)
![Page 22: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/22.jpg)
ROOF PLAN
SCALE: 1:100
M2
2250
MA
22
50
15
00
225022502250
22
50
15
00
22
50
C1
U/N
22
50
M1
U/N
2250 2250
CA
2250 2250 2250 22502700 2700
* REFER TO NOTE 9
300mm/450mm SLAB
500
(TYP)
RS
B2
RS
B2
RS
B2
RS
B2
RSB1
RSB1
REFER ALSO TO 8/S201
FOR ADD'L 15M CONT.
AT SLAB EDGE
15M
@ 2
25 T
20M
@ 2
00 T
20M
@ 2
25 T
15M
@ 2
00 B
15M
@ 2
25 T
15M
@ 2
25 T
15M
@ 2
25 T
33
00
(T
YP
.)3
30
0 (
TY
P.)
15M
@ 2
00 B
15M
@ 2
00 B
20M
@ 2
00 T
20M
@ 2
00 T
20M
@ 2
00 T
33
00
(T
YP
.)1
80
0/3
30
0 (
TY
P.)
CL
AS
S'B
' T
EN
SIO
N
LA
P (
TY
P.)
20M
@ 2
50 B
20M
@ 2
50 B
20M
@ 2
50 B
20M
@ 2
25 T
20M
@ 2
25 T
20M
@ 2
00 B
20M
@ 2
00 B
20M
@ 1
75 B
20M
@ 1
75 B
20M
@ 2
50 B
20M
@ 2
50 B
15M
@ 2
00 B
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
BEND TOP/BOT.
BARS INTO STAIR
(SEE SECTION)
PROVIDE ADD'L INTEGRITY BARS
AT ALL COLUMNS (SEE NOTES)
- ALL COLUMNS TO BE
CONSIDERED AS "INTERIOR" U/N.
3-20M @ 150 T&B ADD'L
- EXTEND 1200 PAST FACE OF OPENING
- HOOK 90° AT DISCONTINUOUS EDGES
- DIAGONALS: 1200 LONG
3-20M 1800 @ 150 T ADD'L
AT EACH WALL/STAIR
CORNER (TYP)
HOOK BOTTOM BARS
AT CANTILEVER ENDS
(TYP.)
20M
@ 2
00 B
20M
@ 2
50 B
15M
@ 2
00 B
15M
@ 2
00 B
20M
@ 2
50 B
20M
@ 2
00 B
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
20M
@ 1
75 B
20M
@ 1
75 B
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
15M
@ 2
50 B
15M
@ 2
50 B
20M
@ 1
75 B
20M
@ 1
75 B
20M
@ 2
50 B
C2
U/N
*C
2*
33
00
(T
YP
.)
33
00
(T
YP
.)
20M
@ 1
75 B
20M
@ 1
75 B
20M
@ 2
00 T
20M
@ 2
00 T
18
00
/33
00 (
TY
P.)
33
00
(T
YP
.)
20M
@ 2
00 T
20M
@ 2
00 T
20M
@ 2
25 T
BEND TOP/BOT.
BARS INTO STAIR
(SEE SECTION)
EXTEND ALL BOTTOM
BARS INTO STAIR (TYP)
33
00
(T
YP
.)
20M
@ 2
50 B
20M
@ 2
00 T
20M
@ 2
00 T
15M
@ 2
25 T
15M
@ 2
25 T
20M
@ 2
00 T
15M
@ 2
25 T
15M
@ 2
25 T
20M
@ 2
00 T
20M
@ 2
00 T
CL
AS
S 'B
'
TE
NS
ION
LA
P
(TY
P.)
18
00
/33
00 (
TY
P.)
20M
@ 2
25 T
20M
@ 2
25 T
20M
@ 2
50 B
18
00
/33
00 (
TY
P.)
15M
@ 2
00 B
15M
@ 2
00 B
33
00
(T
YP
.)
20M
@ 2
00 T
20M
@ 2
50 B
33
00
(T
YP
.)
15M
@ 2
25 T
15M
@ 2
00 B
15M
@ 2
00 B
15M
@ 2
25 T
15M
@ 2
00 B
PROVIDE 180° HOOK
OUTSIDE OF STAIR
(TYP.)
CL
AS
S'B
' T
EN
SIO
N
LA
P (
TY
P.)
REFER TO STAIR SECTIONS
FOR ADD'L REBAR AT STAIR
EDGES (TYP.)
4-20M @ 100 T&B
ADD'L AT OPENING
EDGE (EXTEND
1200 PAST FACE)
PARTIAL PLAN: ELEVATOR OVERRUN
SCALE: 1:100
15M @ 350 TUL/BLL
15M @ 350 TLL/BUL
250mm CONC. SLAB
200mm CONC. SLAB
20M @ 300 TUL
20M @ 300 TLL
15M
@ 3
00
BU
L
15M 1800 @ 300 TLL (E.E.)
5. FLAT SLAB GEOMETRY U/N:
SLAB: 425 MAX./275 MIN. THICK - 450 MAX/300 MIN.
DROPS: 3000x3000x240 U/N
SLAB BANDS: 240 U/N
FLARES: 200 U/N
CONCRETE: 30 MPa U/N
T.O.C. EL.: P.H. FLOOR: 16,200
T.O.C. EL.: ROOF: 16,200 (LOW POINT)
T.O.C. EL.: ROOF: 16,350 (HIGH POINT)
WHERE fc' WALL OR COLUMN > 10 MPa + fc' SLAB: PROVIDE PUDDLE OF CONCRETE AT
COLUMNS/SHEARWALLS THAT MATCHES STRENGTH OF VERTICAL ELEMENT. EXTEND
PUDDLE TO MIN. OF 600mm ALL AROUND VERTICAL ELEMENT.
PROVIDE VARYING HEIGHT CHAIRS TO TOP STEEL TO MAINTAIN 25mm CLEAR COVER FROM
TOP OF SLOPING SLAB.
REFER TO LEVEL 3 REINFORCING U/N.
6. DESIGN LOADS
ROOF AREAS: CONCRETE SLAB:
DEAD: 425 MAX/275 MIN. CONC.: 9.00 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa (CONVENTIONAL)
11.75 kPa
LIVE: ROOF: 1.00 kPa
SNOW: 2.40 kPa (+ DRIFT)
CONCRETE SLAB/REBAR NOTES:
1. COVER: BOT. = 25mm CLEAR TO BLL
TOP = 25mm CLEAR TO TUL
2. REINFORCING STEEL LAYOUT:
REINFORCING TO BE SIMILAR TO 3rd FLOOR U/N.
3. MINIMUM REINFORCING:
BOT: CS: 20M @ 200 (+ HOOK AT CANTILEVER ENDS)
MS: 15M @ 200 (+ HOOK AT CANTILEVER ENDS)
TOP(INT.): CS: 20M @ 200
TOP(EXT.): CS: 20M @ 250 (+ HOOK AT DISCONTINUOUS ENDS)
MS: 15M @ 250 (+ HOOK AT DISCONTINUOUS EDGE)
4. INTEGRITY STEEL @ COLUMNS:
(OVER WIDTH OF COLUMN CAP)
PROVIDE ADD'L BOTTOM STEEL AT ALL COLUMNS U/N.
INTERIOR COLUMN: 4-25M B.E.W.
EXTERIOR COLUMN: 4-25M B + HOOK
EXTERIOR CORNER: 4-25M B +HOOK
BLL
TUL
BUL
TLL
7. TYPICAL DETAIL: OPENINGS (U/N)
TERMINATE
AFFECTED STEEL @
FACE OF OPENING
PROVIDE EQUIVALENT AREA OF
STEEL (BASED ON TERMINATED
BARS) E.S. OF OPENING @ 12
SPACING (MIN. 2-15MB)
TERMINATE AFFECTED STEEL @
FACE OF OPENING
(c/w: HOOK)
BARS ARE TO EXTEND FULL
LENGTH NOTED ON DRAWINGS
(MIN. 1200mm (4'-0") FROM FACE
OF OPENING)
PROVIDE 3-20M @ 150(6")
ADD'L E.S. OF OPENING
(EXTEND 1200mm (4'-0")
PAST EDGE)
TERMINATE AFFECTED STEEL
@ FACE OF OPENING
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
BOTTOM STEEL
PROVIDE 1-15Mx800(32")
LONG ADD'L @ CORNERS
TOP STEEL
CONTRACTOR IS REQUIRED TO SUBMIT SLEEVING AND CONDUIT DRAWINGS (IN-SLAB)
TO ENGINEER FOR REVIEW A MINIMUM OF 20 WORKING DAYS
PRIOR TO CONC. PLACEMENT. DRAWINGS ARE TO DETAIL AND DIMENSION ALL
ELEMENTS PASSING THROUGH/IN SLAB. ANY SLEEVING/OPENINGS/ IN
SLAB ELEMENTS NOT INDICATED ON REVIEWED DRAWINGS MAY BE REMOVED BY
ENGINEER ON SITE AT CONTRACTOR'S OWN EXPENSE. NO CONCRETE
IS TO BE PLACED PRIOR TO RECEIVING WRITTEN APPROVAL OF ENGINEER. SEE ALSO
S000 SERIES OF DRAWINGS FOR DETAILS. DURING SHOP DRAWING REVIEW ENGINEER
MAY REMOVE ANY/ALL CONDUIT FROM SLAB NOT DEEMED SATISFYING TYPICAL
REQUIREMENTS AT NO ADDITIONAL COST TO THE PROJECT.
8. SLEEVING/CONDUIT
9. EXTERIOR EDGE CONDITIONS:
UNLESS OTHERWISE NOTED ON PLANS, PROVIDE COLUMN STRIP TOP/BOT BARS AT
EXTERIOR EDGES, WITH REDUCTION IN BAR SPACING OF 50mm (2``). BAR SIZE TO
REMAIN AS NOTED
(ie. C#(INT): 20M @ `250 B, C#(EXT): 20M @ 200 B)
10. SLAB BANDS:
IN PORTIONS OF SLAB CONTAINING SLAB BANDS LOWER LONGITUDINAL BOTTOM
STEEL TO BOTTOM OF SLAB BAND. PROVIDE TYPICAL BOTTOM STEEL COVER
REQUIREMENTS U/N.
11. CLADDING SUPPORTS:
ALL CLADDING ELEMENTS (CURTAIN WALL/MASONRY/METAL PANELS) TO BE
SUPPORTED VERTICALLY/LATERALLY AT EACH FLOOR LEVEL. DESIGNS FOR THESE
ELEMENTS THAT ARE SHOWN SUPPORTING MULTI FLOORS AT A SINGLE LEVEL WILL
BE REJECTED AND REDESIGNED/CONSTRUCTED AT CONTRACTOR'S OWN COST.
12. REFER TO S000 SERIES DRAWINGS FOR CAMBERING OF SLAB.
13. ADD'L 3-20M T & B @ FACE OF SLAB OPENINGS TO BE PROVIDED.
MECH. AREAS: CONCRETE SLAB:
DEAD: 275 CONC.: 6.60 kPa
240 DROPS: 1.65 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
8.85 kPa
LIVE: MECH. ROOM: 7.20 kPa (INCL. 100mm EQUIP/PADS)
ELEVATOR OVERRUN:
DEAD: 200 CONC.: 4.80 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
FLOORING: 0.10 kPa
5.40 kPa
LIVE: MECH. ROOM: 7.20 kPa (INCL. 100mm EQUIP/PADS)
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
1:100S104R2
ROOF
(REINFORCING PLAN)
![Page 23: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/23.jpg)
PENTHOUSE ROOF PLAN
SCALE: 1:100
B C D E F
3
2
7500 10500 7500 9000
60
00
NOTES:
DESIGN OWSJ SHOES FOR THE FOLLOWING ULTIMATE ROLL OVER
FORCES (PLUS APPLICABLE AMPLIFICATION FACTORS) DUE TO SEISMIC
LOADS: 15 KN (APPLIED AT TOP OF JOIST SHOE)
DENOTES COLLECTOR FORCES MULTIPLY VALUES BY 1.5 FOR
CONNECTION DESIGN.
W15
0x37
400
DP
OW
SJ @
100
0 o
.c.
(MA
X.)B
6A
(TYP)
400
DP
OW
SJ @
100
0 o
.c.
(MA
X.)
38mmx1.52(16ga.) GALV. STEEL DECK
c/w: 19mm Ø PUDDLE WELDS
(SCREWS NOT ACCEPTABLE ALTERNATE)
• @ 914/9 TRANSVERSE
• @ 150mm o.c. AT PERIMETER
• SIDE LAP BUTTON PUNCH @ 300 o.c.
L 51x38x6.4 (LLH) CONT.
AT PERIMETER/EDGES
OF OPENINGS
B 6A (TYP):
400x250x16
c/w: 4-20mmØ ANCHORS
(WELD ANCHORS TO U/S OF PLATE FOR FULL
SHEAR/TENSION CAPACITY OF ANCHOR)
150 DEEP JOIST SHOE
EXTENSIONS (TYP)
2-LINES DIAGONAL
X-BRIDGING (MIN.)
S201
1
W460x128 W460x128 W460x60 W460x128
W460x128 W460x128 W460x60 W460x128
CRANK W150 FRAMING
OVER STAIRS TO
CREATE SLOPES (TYP)
70 kN
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2
SC2S
C2
SC2
S201
4
S201
4
S201
4
350
75
W150x37 @ 500 o.c.W150x37 @ 500 o.c.
C150x12 BETWEEN JOIST
SHOE EXTENSIONS (TYP)
SEE SECTION FOR
KICKERS TO BEAM FLANGE
CRANK JOISTS ACROSS
ROOF AS REQUIRED TO
CREATE SLOPES (TYP)
SC1
SC1
SC1
SC1
SC1
SC1
SC1
SC1
T.J
.T
.J.
T.J
.T
.J.
T.J
.T
.J.
S201
3
TYP.
SCREEN DIAGONAL:
HSS 102x102x8.0 (HOT DIP GALV.)
• BRACES TO BE DESIGNED WITH
BOLTED CONNECTIONS TO ALLOW
FOR REMOVAL/REINSTATEMENT
DURING MECH. UNIT SERVICING
BRIDGING SUPPLIER TO
PROVIDE CONNECTION
PLATE AT CONC. WALLS (TYP)
REFER TO SECTIONS FOR
SHEAR TABS BETWEEN BEAMS
80 kN 100 kN70 kN
80 kN 70 kN
30 k
N
70 kN
20
0 k
N
100 kN100 kN
100 kN
20
0 k
N
30 k
N
S201
1
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
R.D
.(-15
0)
EL. T.O.S. (U/S OF DECK): 20.325mm (HP)
EL. T.O.S. (U/S OF DECK): 20.175mm (LP)
1. DESIGN LOADS:
DEAD: DECK: 0.10 kPa
JOISTS: 0.25 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 0.60 kPa
1.45 kPa
LIVE: ROOF: 1.00 kPa
SNOW: 2.40 kPa + DRIFT U/N
PENTHOUSE ROOF NOTES:
PENTHOUSE ROOF PLAN
1:100S105
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
![Page 24: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/24.jpg)
6900
6175
6175
10900
6950
525
0
517
5
535
0
570
0
590
0
H
J
K
L
M
N
5
6
7
8
9
10
11
532
5
K'
75
5'
600
CC2
CC1
CC1
200
S200
1
S200
2
PROVIDE MIN. 1800 FROST
COVER TO EXTERIOR
FOOTINGS
STEP FTG
DOWN
STEP FTG
DOWN
40mm DEEP SAWCUTS
c/w: LOADFLEX JOINT FILLER
BF
1
SCT3
SCT3
SCT3
SCT2
SCT5
SCT4
SCT4
SCT1
PT1
FT2
SCT1
PT1
FT2
RETAINING WALLS
• REFER TO ARCH/CIVIL/LANDSCAPE
FOR EXTENTS
150mm CONC. SLAB ON GRADE
c/w: 152x152 MW18.7x18.7
T.O.C. EL. 0000 (DATUM)CC2
B1
B1
B1
FW
1F
W1
B1
S 'B')
RNERS
FW
3F
3
F4
F4
S200
2
FWT1
FW
T1
FWT1
350
BTD
FT1PT1
FT3BTD
PT1
BTD
BTE
PT2
FT3
3000
300
0
BTE
PT2
150
0
SCT1
PT1
FT2
SCT4
PT2
SCT1
PT1
FT2
PT1
BTD
FT3
3000
150
0
SCT4
BTE
PT2
SCT4
BTE
PT2
BF
1
FT
1
FT
1
FT
1
FT
1
SCT1
PT1
FT2
BTD
BTD
BTE
BTD
BTD
TOP OF FOOTINGS AT BRACE TO
BE -1200 FROM T.O.PIER TO
ALLOW ANCHOR CLEARANCE
(INCREASE DEPTH TO SUIT
GEOTECHNICAL REQUIREMENTS)
FT2
STEP FTGDOWN
PROVIDE 190mm CONC. FDN WALL
AT BLOCK WALL ENCLOSURE
c/w: 15M @ 300 VERT. + DWLS
15M @ 300 HOR. CONT.
(REFER TO TYPICAL NOTES FOR
MASONRY REQUIREMENTS)
STEP FTGDOWN
PROVIDE MIN. 1800mm FROST
COVER TO EXTERIOR WALL
FOOTINGS OF TEST BUILDING
PROVIDE B1 BUNDLE
AT WALL ENDS (TYP)
- SEE TOWER PLANS
350
B1
B1
B1
B1
B1
FT
1
FWT1: 350mm CONC. WALL
c/w: • 25M @ 150 V.I.F. + DWLS
• 15M @ 300 V.O.F. + DWLS
• 15M @ 300 H.I.F. CONT.
• 15M @ 300 H.O.F. CONT.
• 2-20M H.E.F. CONT. AT TOP
• fc' = 25 MPa, F-2
BTF
SCT5
SCT5
SCT5
PT3
BTF
PT3
BTF
PT3
BTFP
T3
FT6FT6
FT6
FT6
PROVIDE MIN. 2100 FROST
COVER TO LINK FOOTINGS /
FOOTINGS OF TOWER THAT
ARE IN PROXIMITY
PT1B
TD
FT7
FT5
FT
5
FT5
ST200
1
INCREASE THICKNESS OF FT6
TO MATCH TOWER FOOTINGS
WHERE THEY COMBINE
FW3 (REFER TO SECTIONS)
BACKFILL BERMS WITH LIGHT
WEIGHT FILL/ENGINEERED
SOIL STABILIZATION AS PER
GEOTECHNICAL REPORT
(TYPICAL ALL LOCATIONS)
BACKFILL BERMS WITH LIGHT
WEIGHT FILL/ENGINEERED
SOIL STABILIZATION AS PER
GEOTECHNICAL REPORT
(TYPICAL ALL LOCATIONS)
ST200
1
FWT1
REFER TO 4/ST200
FOR REINFORCING
OF FWT1FT
5
FT7
FW
T2
FW
T2
FW
T2
FWT2
FW
T2
U/S OF FOOTINGS AT
BRACE TO BE -1500
FROM T.O.C. (MIN.)
TOP OF CONC. PIERS
TO BE AT -300 FROM
U/S OF SLAB
ST200
1
350
ST200
4
ST200
4A
ST200
4
ST200
5
ST200
4
ST200
6
ST200
5
ST200
4
40mm DEEP SAWCUTS
c/w: LOADFLEX JOINT FILLER
350
IN FWT1 ALONG LOADING
DOCK DOORS PROVIDE
15M @ 300 V.I.F. - NOT 25M)
1500FT4
BF2
SCT2
PT1B
TD
FT7
FT
4
SCT4
PT2
BTE
325
SCT4
PT2
BTE
1500FT4
BF2
SCT4
PT2
BTE
325
150
0
150
0
300
0
FT
4
SCT3
PT1
BTD
FT3
REFER TO ARCH. FOR FLOOR
SLOPES/EXTENTS
- SEE ALSO TYPICAL DETAILS
ST200
7
PROVIDE BENT PLATE
SILL AT EACH DOOR
(TYP) (SEE SECTION)
C150x19 E.E. OF OVERHEAD DOOR:
c/w: 200x150x12 B WITH 2-16mmØ ANCHORS
• PROVIDE SLOTTED CONNECTION TO
BEAM AT TOP TO ALLOW FOR -25mm
DOWNWARD DEFLECTION
• PROVIDE C150x19 HOR. AT TOP OF
DOOR c/w: 12mmØ SAG ROD TO ROOF
BEAM AT MID-POINT
250
50
1500
PROVIDE 300x175x16 B
c/w: 4-16mmØ ANCHORS FOR
SCT1 @ O.H. DOOR
300
50 EXTEND CONCRETE FDN WALL TO
BE FLUSH WITH TOP OF SILL PLATE
BETWEEN O.H.D. FRAMES
350x400 PIER
c/w: 6-20M VERTS. + DWLS
4-10M TIES @ 150 o.c.
SCT1
10
GENERAL NOTES:
1. ALL BEARING ELEVATIONS ARE TO BE CONFIRMED/COORDINATED WITH
GEOTECHNICAL REPORT/DATA. WHERE GEOTECHNICAL REPORT INDICATES
BEARING ELEVATIONS THAT ARE LOWER THAN THOSE PROVIDED,
GEOTECHNICAL REPORT VALUES GOVERN. CONTRACTOR IS RESPONSIBLE
FOR COORDINATION BETWEEN BOTH SETS OF DATA PROVIDED.
2. LOWER FTGS IN AREAS ADJACENT TO UNDERGROUND SERVICES/PITS AS
REQUIRED TO MAINTAIN MINIMUM 2H/1V ELEVATION OFFSET FOR BEARING
SURFACES (REFER TO S000) (TYP. ALL LOCATIONS).
3. ENGINEERED FILL/COMPACTED GRANULAR:
REFER TO GEOTECHNICAL REPORT FOR ALL REQUIREMENTS.
NOTES:
1. ALL FOOTINGS TO BEAR ON SUITABLE BEARING STRATA AS APPROVED BY
GEOTECHNICAL ENGINEER/IN ACCORDANCE WITH GEOTECHNICAL REPORT
WITH MINIMUM BEARING PRESSURES NOTED IN TABLE.
2. PROVIDE MINIMUM 1500(5'-0") FROST COVER TO ALL FOOTINGS EXPOSED TO
EXTERIOR CONDITIONS U/N ON DRAWINGS/GEOTECHNICAL REPORT.
3. CONCRETE STRENGTH: fc' = 25 MPa U/N.
4. TOPS OF INTERIOR FOOTINGS TO BE A MINIMUM OF 300mm(12") BELOW THE
U/S OF THE SLAB ON GRADE. STEP DOWN INTERIOR FOOTINGS TO EXTERIOR
FOOTINGS AS REQUIRED. FINAL BEARING ELEVATIONS TO BE BASED ON
GEOTECHNICAL INVESTIGATION.
5. FOOTING AND BOTTOM OF WALL ELEVATIONS TO BE ESTABLISHED FROM
PLANS AND GEOTECHNICAL REPORT. WALLS/COLUMNS ARE TO BE
TERMINATED SUCH THAT THEY ARE FOUNDED ON COMPETANT BEDROCK
(WITH APPROPRIATE FROST COVER) APPROVED BY GEOTECHNICAL ENGINEER
ON SITE.
6. GEOTECHNICAL ENGINEER TO CONFIRM ALL BEARING CAPACITIES ON SITE
PRIOR TO PLACING CONCRETE.
7. FOOTINGS ARE TO BE LOWERED AS REQUIRED IN THE AREAS OF PITS/SHAFTS
@ FOUNDATION LEVEL SUCH THAT THE U/S OF THE PIT /SHAFT IS AT THE TOP
OF THE FOOTING. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF
ELEVATIONS/STEPS IN FOOTINGS. CONTRACTOR IS REQUIRED TO PREPARE
FOOTING ELEVATION DRAWINGS PRIOR TO EXCAVATION.
8. 15M SIDE BARS @ 200mm (8") o.c. REQUIRED FOR FOOTINGS 600mm (24") DEEP
AND GREATER.
9. HOOK FOOTING BARS 90° WHERE EDGE OF FOOTING IS LESS THAN 600mm(24")
PAST EDGE OF SUPPORTED PIER/WALL.
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FOOTING SCHEDULE - TEST FACILITY
NOTESMARK
FT1 EXTERIOR STRIP FOOTING AT GLAZING
3-15M BOT. LONG.
fc' = 25 MPa, N
500x250
SIZE (LxWxT)
1. TOPS OF INTERIOR/EXTERIOR PIERS TO BE @ 300(12") BELOW THE
UNDERSIDE OF THE SLAB ON GRADE.
2. PIER DIMENSIONS ARE TO BE CENTRED ON SUPPORTED COLUMNS (U.N.O.).
INCREASE CONCRETE SIZE TO SUIT FOUNDATION WALL OFFSETS.
3. VERTICAL BARS IN PIERS MAY BE LAPPED WITH COMPRESSION LAPS WHERE
NO BRACE/MOMENT FRAMES ARE PRESENT. WHERE BRACE/MOMENT
FRAMES ARE PRESENT VERTICAL BARS ARE TO EXTEND TO FULL HEIGHT
ABOVE FOOTING TO TOP OF PIERS (NO LAPS ARE PERMITTED UNLESS
APPROVED BE ENGINEER IN WRITING). CLASS `B' TENSION LAPS (MIN. 1.5 ld)
MAY BE USED WHERE HEIGHT OF PIER EXCEEDS 2400(8'-0").
4. SEE ALSO TYPICAL DETAILS S004.
NOTES:
PIER SCHEDULE - TEST FACILITY
REINFORCINGSIZE
TYPICAL PIER
c/w: 8-20M VERT. + DWLS
2-10M TIES @ 300 o.c.
(+ ADD'L T&B)
PT1 500x500
MARK
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FT2 INTERIOR FOOTINGS
15M @ 300 B.E.W.
fc' = 25 MPa, N
1200x1200x300
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FT3 EXTERIOR PAD FOOTINGS
3-15M B.E.W.
fc' = 25 MPa, N
800x800x300
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FT4 BRACE FRAME PAD FOOTINGS
20M @ 250 B.E.W.
20M @ 250 T.E.W. IN 3mx3m MAT AT EACH COL.
fc' = 25 MPa, N
3000x500
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FT6 LINK PIER FOOTINGS
20M @ 200 B.E.W.
20M @ 200 T.E.W.
fc' = 25 MPa, N
3000x3000x600
BRACE PIER
c/w: 16-20M VERT. (FULL HEIGHT)
3-10M TIES @ 250 o.c.
(+ ADD'L T&B)
PT2 650x650
LINK MOMENT FRAME PIER
c/w: 20-25M VERT. (FULL HEIGHT)
5-10M TIES @ 300 o.c.
(+ ADD'L T&B)
PT3 1000x1000
REMARKSMARK SIZE
250x200x16450
50
GIRDER PLATE
4-16mmØ ANCHOR BOLTS
(WELD TO U/S OF PLATE)
B TA
BASEPLATE SCHEDULE - TEST FACILITY
(SEE 1/S200T) COLLECTOR GIRDER PLATE
(SEE 1/S200T FOR DETAILSB TB
150x200x16
(MIN. SIZE)300
50
TYP. JOIST ANCHOR
2-16mmØ ANCHOR BOLTS
(INCREASE SIZE OF PLATE TO SUIT
JOIST DESIGN REQUIREMENTS)
B TC
300x300x20300
50
INTERIOR BASEPLATE
4-16mmØ ANCHOR BOLTSB TD
450x450x50900
BRACE BASEPLATE
4-32mmØ SEISMIC HEADED ANCHORS
+ W200x71 SHEAR STUB x 250 LONG
B TE
850x850x751100
LINK PIER MOMENT FRAME PLATE
8-32mmØ SEISMIC HEADED ANCHORSB TF
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FT5 SHEAR WALL STRIP FOOTING
4-15M BOT. LONG.
fc' = 25 MPa, N
800x300
SIZEMARK
SCT1 HSS 152x152x8.0
STEEL COLUMN SCHEDULE - TEST FACILITY
NOTES
1. REFER TO PLANS FOR ELEVATIONS AND ORIENTATIONS.
2. ALL HSS COLUMNS TO BE CLASS 'C'.
NOTES:
TYPICAL INTERIOR COLUMN
SCT2 INTERIOR COLUMN AT BRIDGEHSS 152x152x13
SCT3 EXTERIOR COLUMNHSS 152x152x6.4
SCT4 BRACE COLUMNHSS 152x152x13
SCT5 BRIDGE COLUMNHSS 508 Ø x 13
qSLS ≥ 200 kPa
qULS ≥ 350 kPa
FT7 LINK PADS AT BUILDING
20M @ 300 B.E.W.
fc' = 25 MPa, N
1800x1800x400
1. LENGTH OF ANCHORS IS EMBEDMENT LENGTH. FABRICATOR TO PROVIDE
ADDITIONAL LENGTH AS REQUIRED FOR THREADS/NUTS/TOLERANCES, ETC.
2. ALL ANCHORS TO BE CAST-IN OR GROUTED INTO PLACE.
3. PROVIDE MIN. 25(1") THICK GROUT BED BELOW BASE PLATE
NOTES:
BASEPLATE
(REFER TO SCHEDULE)
COLUMN
(REFER TO PLANS)
CAST-IN POCKET
FOR LUG
50
(2")
(TY
P.)
30
0(1
2")
ANCHOR BOLTS
(REFER TO SCHEDULE)
GROUT TUBE INTO
POCKET @ ERECTION
CONCRETE PIER
(REFER TO PLANS)
SHEAR LUG
(REFER TO SCHEDULE)
4. SEISMIC SHEAR LUG DETAIL (PROVIDE AS REQUIRED IN SCHEDULE)
5. SEISMIC HEADED ANCHORS: FOLLOWING OUTLINES MINIMUM WASHER PLATE
(c/w: NUT ABOVE/BELOW PLATE) SIZES FOR BOLT ENDS.
(5 8"Ø: 2"x2"x58")
(3 4"Ø: 2 12"x2 12"x5
8")
(1"Ø: 3"x3"x34")
(1 14"Ø: 3 12"x3 12"x3
4")
(1 12"Ø: 4"x4"x34")
6. ANCHOR BOLT EMBEDMENT LENGTHS HAVE BEEN DEVELOPED IN
ACCORDANCE WITH CAN/CSA A23.3-04 CLAUSES 7.1.4, ANNEX D, 12.2, AND
21.2.7. DEPTHS ARE BASED ON MINIMUM EMBEDMENTS AND THE
DEVELOPMENT OF THE PIER REINFORCING STEEL IN TENSION ABOVE THE
CONE OF FAILURE CREATED BY THE BOLT HEAD.
7. VERTICAL ANCHOR PLATES/CONTINUOUS WELD PLATES:
• PROVIDE MIN. 1-10M HOR. AT END/BEND OF ALL STUD/STRAP ANCHORS.
10M TO BE CONTINUOUS WHERE MULTIPLE PLATES ALIGN. WHERE PLATE IS
ISOLATED, PROVIDE MIN. 36" LONG BAR.
• FACE OF PLATES TO BE CAST-IN FLUSH WITH FACE OF CONCRETE.
• WELD ANCHORS TO PLATE TO DEVELOP FULL SHEAR/TENSION CAPACITY
OF ANCHORS.
OF BRACE
16mmØ: 52x52x16mm
19mmØ: 63x63x16mm
25mmØ: 76x76x20mm
32mmØ: 76x76x20mm
38mmØ: 102x102x20mm
DETAIL
8. PROVIDE MIN. 1-15M x 32" LONG REBAR AT EACH STRAP ANCHOR AT
EMBEDDED ENDS.
TEST FACILITY: FOUNDATION/GROUND FLOOR PLAN
SCALE: 1:100
STORAGE ROOF:
DEAD: 200mm CONC. 4.80 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
5.30 kPa
LIVE: ROOF: 1.0 kPa
DESIGN LOADS:
TEST FACILITY: NUCLEAR STORAGE ROOF PLAN
SCALE: 1:100
ALL BLOCK VERT'S TO
BE IN GROUTED CORE
190 BLOCK WALLS BELOW:
• 15M @ 600 o.c. VERT. + DWLS
• 3-15M VERT. + DWLS ADD'L AT CORNERS
• 2-15M VERT. + DWLS ADD'L E.S. OF DOOR
• HDMR (TRUSS TYPE) @ 200 o.c.
• 1-20M HOR. ADD'L IN 2 COURSE DEEP
BOND BEAM CONT. AT TOP OF WALLS
• ALL LAPS TO BE CLASS 'B' TENSION
• PROVIDE LINTEL OVER DOOR AS PER
TYP. DETAILS ON S002
200 CONCRETE SLAB:
• fc' = 25 MPa, N
• 15M @ 300 T.E.W.
• 15M @ 300 B.E.W.
BEND BLOCK WALL
DOWELS INTO SLAB
TEST FACILITY:
FOUNDATION / GROUND
FLOOR PLAN
1:100ST100
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
RE
FE
R T
O D
RA
WIN
G S
10
0 F
OR
MA
IN B
UIL
DIN
G
![Page 25: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/25.jpg)
6900
6175
6175
10900
6950
525
0
517
5
535
0
570
0
590
0
H
J
K
L
M
N
5
6
7
8
9
10
11
532
5
K'
75
5'
600
S200
3
BTA
BTA
T.J.T.J.
T.J. T.J.
W310x39
T.J.
W5
30x123
W530x123
W530x123
700 DP OWSJ @ 1000 o.c. (MAX.)
500 DP OWSJ @ 1000 o.c. (MAX.)
W410x39
W360x33
C20
0x17
AT
ED
GE
SCT1
SCT1
SCT4
SCT4
SCT1
SCT3
SCT3
SCT3
SCT3
SCT3
SCT4
SCT4
SCT4
SCT4
SCT1
SCT1
SCT2
38mmx1.52(16ga.) GALV. STEEL DECK
c/w: • HILTI-X-ENP19 FASTENERS @ 914/9
• HILTI SLC SIDE LAPS @ 150 o.c.
• PERIMETER/EDGES: HILTI-X-ENP19 @ 150 o.c.
L 152x102x7.9 (LLH) CONT.AT PERIMETER
CC2
CC1
CC1
CC2
FW
1F
W1
S200
3
200
350
W460x74W
460x52
Cu
=T
u=
125 k
N
Cu
=T
u=
250 k
N
Cu
=T
u=
400 k
N
Cu
=T
u=
250 k
N
Cu
=T
u=
400 k
N
Cu
=T
u=
120 k
N
T.J.
T.J.
T.J.
500 DP OWSJ @ 1000 o.c. (MAX.)
BTA
150
Cu=Tu=120 kN
SCT5
SCT5
SCT5
SCT5
W530x123
Cu=Tu=120 kN
BTB
SKEW BEAM AS REQUIRED
TO FRAME ONTO OF
BEARING PLATE
SEE SECTION
1/S200T
FRAME INTO SIDE
OF GIRDER
Cu=Tu=220 kNW310x39
Cu=Tu=360 kN W460x74
Cu=Tu=530 kN
150200
350
BTB
W410x39Cu=Tu=150 kN
Cu=Tu=80 kN
W360x51
W360x33
W360x33
W360x33
W460x52
W310x21
W360x51
W360x51
W460x52
W360x51
W360x51
W360x51
W360x51
W360x51
W360x51
150
200 2
00
ST200
3
500 DP OWSJ @1000 o.c. (MAX.)
500 DP OWSJ @ 1000 o.c. (MAX.)
500 DP OWSJ @ 1000 o.c. (MAX.)500 DP OWSJ @ 1000 o.c. (MAX.)
500 DP OWSJ @ 1000 o.c. (MAX.)
500 DP OWSJ @ 1000 o.c. (MAX.)500 DP OWSJ @ 1000 o.c. (MAX.)
500 DP OWSJ @ 1000 o.c. (MAX.)
Cu=Tu=120 kN
W530x123
Cu=Tu=120 kN
W530x123
Cu
=T
u=
150 k
NW5
30x123
Cu
=T
u=
150 k
N
C150x12 STUB EXTENSIONS
@ 1000 o.c. (MAX.)
DENOTES FULL MOMENT/SHEAR
CONNECTION OF BEAM TO COLUMN
CANTILEVER JOIST SHOES
TO SUIT DECK EDGE
PROVIDE L 76x76x6.4 KICKERS @
2000 o.c. (MAX.) ON BEAM
- CONNECT TO JOIST PANEL POINTS
- Cu=Tu=15 KN
- TYP. ALL BEAMS WITH COLLECTOR
FORCES NOTED
ALL JOISTS TO BE DESIGNED
FOR A ROLLOVER FORCE
VULT = 25 KN APPLIED AT TOP
OF SHOE (U/S OF DECK)JOIST FABRICATOR TO DETAIL
BRIDGING CONNECTION PLATE
TO CONC. WALL
DIAGONAL X-BRIDGING
(MIN. 2-LINES)
C100x9 @ 1000 o.c. BETWEEN
JOISTS TO U/S OF DECK
• FASTEN TO DECK @ 150 o.c.
• ANCHOR PLATE AT WALL:
150x150x12 c/w: 4-12mmØ
NELSON STUDS (x200 LONG)
• TYP. AT GRID 5 / 12 ALONG
CONC. WALLS
• 3 JOIST SPACES
EACH JOIST BETWEEN GRIDS K
AND N TO BE DESIGNED FOR
ADD'L T.C. COMPRESSION
FORCE OF 100 KN (ULT) APPLIED
AS FACTORED LIVE LOAD
EXTEND 200 WIDE PARAPET ABOVE
ROOF DECK (SEE SECTIONS)
- MAINTAIN REINFORCING STEEL NOTED
FOR BEAMS ALONG BRACE LINES
PROVIDE L 76x76x6.4 KICKERS TO
3RD POINTS (E.S. OF BEAM) / TO
BOTTOM FLANGE
• Cu=Tu=15 KN
• TYP. GRIDS 7/9/5/12
ST200
2
ST200
1
ST200
2NOTES:
DESIGN OWSJ SHOES FOR THE FOLLOWING ULTIMATE ROLL OVER
FORCES (PLUS APPLICABLE AMPLIFICATION FACTORS) DUE TO SEISMIC
LOADS: 25 KN (APPLIED AT TOP OF JOIST SHOE)
DENOTES COLLECTOR FORCES MULTIPLY VALUES BY 1.5 FOR
CONNECTION DESIGN.
SKEW BEAM AS REQUIRED
TO FRAME INTO END OF
WALL/BEARING PLATE
LOCALLY NOTCH CURB AT
GIRDER BASEPLATES
(TYP. ALL LOCATIONS)
ST200
3
8.3 KPa
9800
20M @ 250 T
5M @ 300 T
0M @ 250 T
20M
6000
@ 2
25 T
20M
@ 2
25 T
0 (TYP.)
5M @ 250 T
BF
1
BF
1
BF2
BF2
W310x39
Cu=Tu=220 kNW310x39
Cu=Tu=360 kNW310x39
Cu=Tu=530 kN BTA
SCT4
325
SCT4
T.J.T.J.
T.J. T.J.
T.J.
T.J.
BTA
W410x46
BTA
L 52x52x6.4 KICKERS FROM
W410 BOT. FLANGE TO W460
TOP FLANGE
Cu=Tu=15 KN
- ALIGN ON O/H DOOR VERT'S
EXTEND JOIST SHOES TO
EDGE OF DECK (TYP.)
3-20M @ 100 T&B ADD'L AT
PERIMETER OF ALL SLAB
EDGES (ALL FLOORS)
- BARS TO BE CONTINUOUS
CLA
SS
'B'
TE
NS
ION
LA
P
(MIN
. 9
00m
m)
W360x33
W360x33
W360x33
W460x68
W460x68
SCT1
C150x19
C150x19
C150x19 @ 800 o.c.
C150x19 @ 800 o.c.
500 DP OWSJ @1000 o.c. (MAX.)
10
TEST FACILITY: ROOF PLAN
SCALE: 1:100
DESIGN LOADS:
TEST FACILITY:
DEAD: STEEL: 0.25 kPa
DECK: 0.10 kPa
CEILING: 0.25 kPa
MECH.: 0.25 kPa
ROOFING: 1.50 kPa
2.35 kPa
LIVE: ROOF: 1.00 kPa
SNOW: 2.40 kPa (+ DRIFT U/N)
TEST FACILITY:
ROOF PLAN
1:100ST101
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
RE
FE
R T
O D
RA
WIN
G S
10
1 F
OR
MA
IN B
UIL
DIN
G
![Page 26: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/26.jpg)
S200
1
SCALE 1:20
SECTION: FOUNDATION WALL: CURTAIN WALL SUPPORT
GR. FLOOR
T.O.C. EL. 0.000
UNDISTURBED BEARING SURFACE
• REFER TO SCHEDULES FOR ULS/SLS
• GEOTECHNICAL TO APPROVE PRIOR
TO CONC. PLACEMENT
F3 (SEE PLAN)
ENGINEERED FILL
CONC. SLAB ON
GRADE (SEE PLAN)
CURTAIN WALL
(REFER TO ARCH.)
>1
50
0 (
MIN
. F
RO
ST
CO
VE
R)
WALL FINISH
(REFER TO ARCH.)
FW3: 200 CONC. FDN WALL
c/w: • 15M @ 300 VERT. + DWLS
(HOOK 600mm INTO SLAB)
• 15M @ 300 HOR. (CONT.)
• PROVIDE 1-15M HOR. (CONT.)
ADD'L AT WELD PLATE ANCHOR
INCREASE DEPTH OF FOOTINGS TO SUIT:
• FROST COVER REQUIREMENTS
• ADJACENT DEEPER FOOTINGS
• MECH/ELECT TRENCHES/PITS/SERVICES
MULLION SUPPORT ANGLE
(REFER TO 2/S200)
MULLION SUPPORT ANGLE TO
BE CONTINUOUS AT DOORS
• REFER TO ARCH. FOR
EXTENTS
• PROVIDE WELD PLATE @
750 o.c. IN THOSE AREAS
• SEE 1A/S200
WELD PLATE (REFER TO 2/S200)
SEE PLANS FOR
RECESS LOCATIONS
200
PROVIDE 1-15M ADD'L (CONT.)
AT TOP/ANCHOR ELBOW
2nd FLOOR
T.O.C. EL. 4.200
GR. FLOOR
T.O.C. EL. 0.000
30
0
(MIN
.)
S200
2
SCALE 1:20
SECTION: TYPICAL FOUNDATION WALL
ENGINEERED FILL
(REFER TO
GEOTECHNICAL REPORT)
CONC. SLAB ON
GRADE (SEE PLAN)
REINFORCED CONC.
SLAB (SEE PLAN)
200
CURTAIN WALL
(REFER TO ARCH.)
L 102x102x13 (x150 WIDE) MULLION
SUPPORT ANGLE @ ±1500 o.c.
• COORDINATE LOCATIONS OF
SUPPORTS / WELD PLATES WITH ARCH.
WALL FINISH
(REFER TO ARCH.)
200 CONC. CURB
c/w: • 15M @ 300 VERT.
• 4-15M HOR. (CONT.)
(1 TOP / 1 AT ANCHORS /
2 EQ. SPACING)
MULLION WELD PLATE:
L 203x152x9.5 (x200 WIDE) (LLV)
BENT PLATE @ ± 1500 o.c.
c/w: • 2-20mm Ø ANCHORS
(CAST-IN) 150
50 BUILT-UP SOIL/ROOFING
• MAX. DEPTH OF SOIL = 300mm
(REMAINING HEIGHT TO BE
PROVIDED USING L.W. INSULATION)
VARY CONCRETE TOP
(MAX. 100mm INCREASE
AT HIGH POINTS)
42
00
(M
AX
.)
UNDISTURBED BEARING SURFACE
• REFER TO SCHEDULES FOR ULS/SLS
• GEOTECHNICAL TO APPROVE PRIOR
TO CONC. PLACEMENT
F3/F4 (SEE PLANS)
INCREASE DEPTH OF FOOTINGS TO SUIT:
• FROST COVER REQUIREMENTS
• ADJACENT DEEPER FOOTINGS
• MECH/ELECT TRENCHES/PITS/SERVICES
CL
AS
S 'B
'
TE
NS
ION
LA
P
900 (TYP)
BEND ALL VERTICALS INTO
SLAB AT TOP (OR PROVIDE
MATCHING DOWELS)
FW1/FW2 (SEE PLANS)
350/300
(SEE PLANS)
WALL FINISH
(REFER TO ARCH.)
10
0
ALL EXTERIOR SUPPORT ANGLES
TO BE HOT DIP GALVANIZED
(TYP. ALL LOCATIONS)
2nd FLOOR
T.O.C. EL. 4.200
S200
3
SCALE 1:20
SECTION: 2ND FLOOR CURTAIN WALL CURB
(SOUTH END)
G
REINFORCED CONC.
SLAB (SEE PLAN)
200
CURTAIN WALL
(REFER TO ARCH.)MULLION SUPPORT ANGLE
(REFER TO 2/S200)
WELD PLATE
(REFER TO 2/S200)
200 CONC. CURB
(SEE 2/S200)
REFER TO PLANS /
2/S200 FOR FOUNDATION
WALL DETAILS
S200
4
SCALE 1:20
SECTION: 2nd FLOOR NORTH ENTRANCE ROOF
A
CURTAIN WALL
(REFER TO ARCH.)
MULLION SUPPORT ANGLE
(REFER TO 2/S200) WELD PLATE
(REFER TO 2/S200)
WALL FINISH
(REFER TO ARCH.)
VARY CONCRETE TOP
(MAX. 100mm INCREASE
AT HIGH POINTS)
BUILT-UP SOIL/ROOFING
• MAX. DEPTH OF SOIL = 300mm
(REMAINING HEIGHT TO BE
PROVIDED USING L.W. INSULATION)
SHOCK CONNECTION BARS
• COORDINATE LOCATIONS
WITH MULLION SUPPORT
ANGLES
• IDENTIFY INTERFERENCES
ON SHOP DRAWINGS
200 CONCRETE CURB
c/w: 15M @ 200 HOR. CONT.
10M @ 300 VERT.
2-20M HOR. ADD'L T&B
(fc' = 35 MPa, C-1)
(FINAL REBAR LAYOUT TO BE
DETERMINED BASED ON
SHOCK CONNECTION SHOP
DRAWINGS/DETAILS)
MULLION WELD PLATE
(REFER TO 2/S200)
DROP BAND (SEE PLANS)
1-15M ADD'L CONT. AT MULLION
WELD PLATE ANCHORS
MULLION SUPPORT ANGLE
(REFER TO 2/S200)
200 CONC. CURB
(SEE 2/S200)
REINFORCED CONC.
SLAB (SEE PLAN)
200
PRE-ENGINEERED REINF.
BARS BY SHOCK CANADA INC.
S200
6
SCALE 1:20
SECTION: 3rd FLOOR: CURTAIN WALL SUPPORT
A
REINFORCED CONC.
SLAB (SEE PLAN)
HSS 76x76 CROSS
MEMBERS (SEE 5/S201)
HSS 76x76 HOR.
(SEE 5/S201)
CONC. COLUMN
(BEYOND)
PRE-ENG. CURTAIN WALL
(REFER TO ARCH.) L 152x102 MULLION CLIPS
(SEE 5/S201)
HSS 76x76 HANGERS
(SEE 5/S201)
HSS 52x52 BRACING
(SEE 5/S201)
HSS 76x76 CONT. HOR.
(SEE 5/S201)
PRE-ENG. CURTAIN WALL
(REFER TO ARCH.)
CURTAIN WALL SUPPORT
FOR LATERAL LOADS ONLY
CURTAIN WALL SUPPORT INSERTS
(REFER TO SUPPLIER'S DETAILS)
ENSURE LAST ROW OF
TRANSVERSE BARS IS
LOCATED EXTERIOR TO
ANCHOR PLATE (TYP)
HANGER ANCHOR PLATE:
150x150x12
c/w: 4-12mmØ NELSON
STUDS x200 LONG
150
G
REINFORCED CONC.
SLAB (SEE PLAN)
HSS 76x76 CROSS
MEMBERS (SEE 5/S201)
HSS 76x76 HOR.
(SEE 5/S201)
CONC. COLUMN
(BEYOND)
PRE-ENG. CURTAIN WALL
(REFER TO ARCH.)L 152x102 MULLION
CLIPS (SEE 5/S200)
HSS 76x76 HANGERS
(SEE 5/S201)
HSS 52x52 BRACING
(SEE 5/S201)
HSS 76x76 CONT. HOR.
(SEE 5/S201)
PRE-ENG. CURTAIN WALL
(REFER TO ARCH.)
CURTAIN WALL SUPPORT
FOR LATERAL LOADS ONLY
CURTAIN WALL SUPPORT
INSERTS (REFER TO
SUPPLIER'S DETAILS)
ENSURE LAST ROW OF
TRANSVERSE BARS IS
LOCATED EXTERIOR TO
ANCHOR PLATE (TYP)
HANGER ANCHOR PLATE:
150x150x12
c/w: 4-12mmØ NELSON
STUDS x200 LONG
S200
7
SCALE 1:20
SECTION: 3rd FLOOR: CURTAIN WALL SUPPORT
150
HSS 76x76 CROSS
MEMBERS (SEE 5/S201)
HSS 76x76 HOR.
(SEE 5/S201)
HSS 52x52 BRACING
(SEE 5/S201)
HSS 76x76 CONT. HOR.
(SEE 5/S201)
PRE-ENG. CURTAIN WALL
(REFER TO ARCH.)
CURTAIN WALL SUPPORT
FOR LATERAL LOADS ONLY
CURTAIN WALL SUPPORT INSERTS
(REFER TO SUPPLIER'S DETAILS)
ENSURE LAST ROW OF
TRANSVERSE BARS IS
LOCATED EXTERIOR TO
ANCHOR PLATE (TYP)
150
L 152x102 MULLION CLIPS
(SEE 5/S201)
HSS 76x76 HANGERS
(SEE 5/S201)
1
4
REINFORCED CONC.
SLAB (SEE PLAN)
CONC. COLUMN
(BEYOND)
PRE-ENG PURLIN/CAP
(REFER TO ARCH.)
PRE-ENG. CURTAIN WALL
(REFER TO ARCH.)
S200
8
SCALE 1:20
SECTION: 3rd FLOOR: CURTAIN WALL SUPPORT
GR. FLOOR
T.O.C. EL. 0.000
S200
A
SCALE 1:25
DETAIL: TYPICAL CONCRETE STAIR
900 (TYP)
200
25
0
LA
ND
ING
25
0
LA
ND
ING
30
0
(MIN
)
75 (TYP. ALL MID
LANDINGS/ALL SIDES)
200
MIN
.
TH
RO
AT (TYP.)
PROVIDE RECESS FOR
NON-SLIP INSERTS IF
REQUIRED (SEE ARCH.)
10M NOSING BAR
(TYP. EACH STEP)
BEND TOP BARS INTO
TOP OF STAIR
STAIR EDGE BEAM:
• 4-20M T @ 100 o.c.
• 4-20M B @ 100 o.c.
• 2-10M TIES @ 250 o.c.
• TYP. AT FLOORS/LANDINGS
150 (TYP)
SLAB/DROP BAND
(SEE PLANS)
BEND BOTTOM BARS
INTO STAIR (TYP)
CONCRETE SHEAR
WALLS (SEE PLANS)
PROVIDE 50x100 SHEAR KEY
INTO WALLS AT SIDE OF STAIRS
c/w: 15M @ 300 DOWELS
900
900
15M @ 300 DWLS
ALL AROUND
LANDINGS (TYP)
900
900
15M @ 200 BLL
(TYP)
15M @ 300 BUL
(TYP)
PRE-ENG. STEEL RAILING
(REFER TO ARCH.)
15M @ 300 TLL
15M @ 200 TUL
15M @ 300 BUL (TYP)
15M @ 200 BLL (TYP)
BEND BOTTOM BARS
INTO STAIR (TYP)
BEND BOTTOM
BARS INTO TOP
(TYP)
SLAB ON GRADE
(SEE PLANS)
15M @ 200 TIES
2-20M T&B
600x250 FTG
c/w: 3-15M BOT.
ENGINEERED FILL
qSLS > 150 kPa
qUSL > 200 kPa
GEOTECHNICAL ENGINEER TO
VERIFY PRIOR TO CONC. PLACEMENT
GR. FLOOR
T.O.C. EL. 0.000
1
1500
T.L.
1500
15
00
T.L.
T.L.
T.L.
300
T.L.
15
00
(M
IN.)
FR
OS
T C
OV
ER
FOOTING (SEE
SCHEDULE FOR DEPTH
AND REINFORCING)
EDGE OF PAD
FOOTING
CONC. SLAB ON
GRADE (SEE PLAN)
WALL REINFORCING
(SEE SCHEDULES)
TOP OF FOOTING ELEV.
TO BE CONFIRMED.
CONTRACTOR TO
COORDINATE ELEVATOR
REQUIREMENTS
EDGE OF FOOTING
FOOTING REINFORCING
(SEE PLAN)
OF WALL
NOTE:
ADDITIONAL REINFORCING LAYERS
ARE NOT SHOWN FOR CLARITY.
S200
5
SCALE 1:25
DETAIL: STEP IN FOOTING
REFER TO PLANS FOR
DEPTH TO TOP OF FTG.
(MEET ELEVATOR
REQUIREMENTS)TIE BEAM
MIN. 50mm THICK
CONCRETE TOPPING
c/w: FIBRE MESH
REINFORCING TO SUIT
DRAINAGE (SEE ARCH.)
S200
1A
SCALE 1:20
SECTION: FOUNDATION WALL: CURTAIN WALL SUPPORT AT DOORS
GR. FLOOR
T.O.C. EL. 0.000
ENGINEERED FILL
CONC. SLAB ON
GRADE (SEE PLAN)
WALL FINISH
(REFER TO ARCH.)
12
CONC. WALL (REFER TO 1/S200)
L 178x102x13 (LLH)
CONTINUOUS AT DOORS
c/w: 6mm STIFFENERS @ 750 o.c.
(MATCH WELD PLATE SPACING)
SEE PLANS FOR
RECESS LOCATIONS
30
0
500
200
WELD PLATE
(REFER TO 2/S200)
PROVIDE 1-15M ADD'L (CONT.)
AT TOP/ANCHOR ELBOW
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
SECTIONS & DETAILS
AS SHOWNS200
![Page 27: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/27.jpg)
3rd FLOOR
T.O.C. EL. 8.200
LATERAL CURTAIN WALL
SUPPORT (BY OTHERS)
• NO VERTICAL SUPPORT
AT THIS LEVEL
38mmx0.91 GALV.
STEEL DECK
L 38x38x6.4 EDGE ANGLE
PRE-ENG MULLION
CAP FINS (SEE ARCH.)
PRE-ENG CURTAIN
WALL (SEE ARCH.)
DRYWALL/STUD FINISH
(REFER TO ARCH.)
HSS 76x76x8.0
@ 1500 o.c.
HSS 76x76x8.0
CROSS MEMBERS
HSS 52x52x6.4
BRACE @ 1500 o.c.
PRE-ENG PURLIN/CAP
(REFER TO ARCH.)
HSS 76x76x8.0
CONT. AT EDGES
HSS 76x76x8.0 @ 1500 o.c. (MAX.)
• ALIGN ON MULLIONS (REFER TO ARCH.)
• REFER TO ARCH FOR LAYOUTS
250 SLAB (BEYOND)
240 SLAB BAND
(BEYOND)
FINISHES (REFER
TO ARCH.)
L 152x102x9.5 (x150 WIDE)
(LLH) @ 1500 o.c. (MAX.)
• ALIGN WITH CURTAIN
WALL MULLIONS
• REFER TO ARCH. FOR
LAYOUTS
HSS 52x52x6.4 DIAGONAL
BRACES AT EVERY 3rd
SPACING + ENDS
PRE-ENG CURTAIN
WALL (SEE ARCH.)
25
02
40
OF
SLAB/BAND
S201
5
SCALE 1:20
SECTION: 3rd FLOOR: ATRIUM GIRT FRAMING
550
75
75
12
51
25
30025
300
HSS 76x76x8.0 HSS 76x76x8.0
HSS 305x305
HSS 305x305
HSS 76x76 (HIGH)
HSS 76x76 (LOW)
65x65x12 SQUARE
WASHER + NUT E.S.
20mmØ ANCHOR
BOLTS (x6)
PROVIDE ADD'L 10M
TIES IN SLAB BAND
@ 100 o.c. IN
ANCHOR AREAS
5-10M TIES ADD'L
(CLOSED HOOP)
A 3B: 490x400x25
ANCHOR PLATE
VF = 70 KN (TYP)
VF = 0 KN @ GRID C
40 KN @ GRID D
S201
6
SCALE 1:20
SECTION: 3rd FLOOR: ATRIUM GIRT SUPPORT AT SLAB
HSS 305x305
S201
7
SCALE 1:20
SECTION: 3rd FLOOR: ATRIUM GIRT SUPPORT AT SLAB
VF = 70 KN (TYP)
CONNECTION AT GRID C:
ALLOW SLOTTED MOVEMENT /
ROTATION AT PIN
CONNECTION AT GRID D:
ROTATION AT PIN ONLY
A 3BSLAB BAND (REFER TO
PLANS FOR REBAR)
REFER TO PLANS
FOR REINFORCING
49
0 ±25 ±25
150
PARAPET ANCHOR PLATE:
150x150x12
c/w: 4-12mmØ NELSON
STUDS x200 LONG
LATERAL SUPPORT CLIP FOR
CURTAIN WALL (NO VERTICAL)
(REFER TO ARCH. FOR DETAILS)
HSS 52x52x6.4 DIAGONALS AT
EVERY 3rd SPACING (+ ENDS)
PROVIDE VARYING HEIGHT
CHAIRS TO TOP BARS TO
MAINTAIN COVER (TYP)
ROOF SLAB
(REFER TO PLANS)
HSS 76x76x8.0 FRAMING @ 1500 o.c. (MAX.)
• CONNECT ALL MEMBERS TOGETHER
FOR FULL M/V CAPACITY OF SECTION
PROVIDE 1-15M ADD'L CONT. AT
-150 FROM TOP OF SLAB OUTSIDE
OF ANCHOR PLATE
PRE-ENG. CURTAIN WALL
(REFER TO ARCH.)
S201
8
SCALE 1:20
SECTION: ROOF: PARAPET SUPPORT FRAMING
VARIES (700 MAX.)
(REFER TO ARCH.)
CURTAIN WALL
(REFER TO ARCH.)
VARY CONCRETE TOP
(MAX. 100mm INCREASE
AT HIGH POINTS)200 CONC. CURB/MULLION
SUPPORT (SEE 2/S200)
200
750
70
055
0
200
CONC. SLAB
(SEE PLANS)
700x750 DROP BAND
c/w: 5-30M BOT. LONG
2-10M TIES @ 250 o.c.
2-15M H.E.F. ADD'L
MULLION SUPPORT
(SEE 4/S200)
PRE-ENG CURTAIN
WALL (SEE ARCH.)
200 CONC. CURB
(SEE 2/S200)
2nd FLOOR
T.O.C. EL. 4.200
BUILT-UP SOIL/ROOFING
• MAX. DEPTH OF SOIL = 300mm
(REMAINING HEIGHT TO BE
PROVIDED USING L.W. INSULATION)
100mm RIGID INSULATION
(REFER TO ARCH.)
S201
9
SCALE 1:20
SECTION: 2ND FLOOR: EXTERIOR ROOFS AT ENTRANCES
S201
10
SCALE 1:20
SECTION: BRIDGE CONNECTION: @ BIG POD
D
25
0
600
10
0
250 CONCRETE SLAB (SLAB
REINFORCING NOT SHOWN FOR
CLARITY/REFER TO REINFORCING
DRAWINGS)
CONCRETE BEAM (REFER TO
SCHEDULE) (REINFORCING NOT
SHOWN FOR CLARITY)
W 1:
500(V) x 350(H) x 16
c/w: 6-20mmØ ANCHOR RODS
- INCREASE SIZE AS REQ. TO SUIT
SHELF ANGLE/BEAM CONNECTION
W410 GIRDER
C100x9 @ 1100 o.c. (TYP.)
38x0.91 COMPOSITE STEEL DECK (TRIPLE SPAN)
w/ 62mm OF CONC. ON TOP (TOTAL DEPTH OF 100mm)
c/w 152x152 MW 18.7x18.7 WIRE MESH @ MID-DEPTH
(REFER TO S000 FOR WELDS)
25
45
0
SHELF ANGLE SUPPORT +
PAD (BY DIV.05)
PRE-ENG. NEOPRENE
BEARING PAD PLUS
ANCHORS TO ALLOW ±
25mm HOR. MOVEMENT
(EACH DIRECTION)
1-15M x 900 LONG @
BENDS/ANCHOR-PLATE ADD'L
2nd/3rd
EXPANSION JOINT COVER
(REFER TO ARCH.)
450
75
S201
11
SCALE 1:20
SECTION: BRIDGE CONNECTION: @ SMALL POD
C
25
04
50
600
10
0
C100x9 @ 1100 o.c. (TYP.)
38x0.91 COMPOSITE STEEL DECK (TRIPLE SPAN)
w/ 62mm OF CONC. ON TOP (TOTAL DEPTH OF 100mm)
c/w 152x152 MW 18.7x18.7 WIRE MESH @ MID-DEPTH
(REFER TO S000 FOR WELDS)
250 CONCRETE SLAB (SLAB
REINFORCING NOT SHOWN FOR
CLARITY/REFER TO REINFORCING
DRAWINGS)
CONCRETE BEAM (REFER TO
SCHEDULE) (REINFORCING NOT
SHOWN FOR CLARITY)
W 1 CAST-IN WALL PLATE (REFER
TO SCHEDULE)
15M @ 200 x 1000 LONG INTO BRIDGE DECK/SLAB
2nd/3rd
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
SECTION AND DETAILS
AS SHOWNS201
![Page 28: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/28.jpg)
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
TEST FACILITY:
SECTION AND DETAILS
AS SHOWNST200
![Page 29: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/29.jpg)
COREWALL/SHEAR WALL NOTES:
1. CONCRETE STRENGTH:
FTG - 2ND: fc' = 40 MPa
2ND - 3RD: fc' = 40 MPa
3RD - 4TH: fc' = 35 MPa
4TH - ROOF: fc' = 35 MPa
ROOF - PHR: fc' = 30 MPa
• MAXIMUM AGGREGATE SIZE IS 20mm UNLESS NOTED ON
COREWALL PLANS.
2. REINFORCING:
ALL WALLS TO BE REINFORCED AS FOLLOWS U/N ON DETAILED
DRAWINGS:
• 20M @ 100 H.E.F.
• 20M @ 350 V.E.F.
• 10-35M @ 150 VERT. +10M TIES @ 100 @ ENDS/EACH SIDE OF
DOORS/OPENINGS/CORNERS
• 4-20M T&B/E.S./E.F. OF MECH. OPENINGS U/N (EXTEND MIN. 600
PAST FACE OF OPENINGS)
• BEND VERTICALS INTO SLAB WHERE WALLS TERMINATE
• ALL LAPS TO BE CLASS `B' TENSION LAPS (MIN. 600, MIN. 1.5 d)
• WHERE WALLS INTERSECT SPACING OF CONCENTRATED
REINFORCING TO BE BASED ON GEOMETRY OF WALLS (AREA OF
CORE CREATED BY INTERSECTION). SPACE ALL OTHER VERT'S
AT SPACING NOTED.
3. GEOMETRY:
FDN - ROOF LEVEL: 350 (MIN.), 400 (MAX.) (SEE PLANS)
SEE COREWALL PLANS FOR DIMENSIONS. REFER TO ARCH.
4. WB1: 350/400x1600
10-25M T (3 LAYERS)
10-25M B (3 LAYERS)
15M @ 150 H.E.F.
2-10M STIRRUPS @ 100 o.c.
WB2: 200x1600
6-25M T (3 LAYERS)
6-25M B (3 LAYERS)
20M @ 100 H.E.F. (OR 150 @ UPPER FLOORS)
10M STIRRUPS @ 100 o.c.
(EXTEND HOR. BARS TO GRID 2&3)
SPACING
NOTED
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
COREWALL DETAILS: CW1
AS NOTEDS300COREWALL DETAIL CW1: FOUNDATION TO SECOND
SCALE 1:50
COREWALL DETAIL CW1: SECOND TO THIRD
SCALE 1:50
COREWALL DETAIL CW1: THIRD TO FOURTH
SCALE 1:50
COREWALL DETAIL CW1: FOURTH TO ROOF
SCALE 1:50
COREWALL DETAIL CW1: PENTHOUSE ROOF
SCALE 1:50
![Page 30: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/30.jpg)
COREWALL/SHEAR WALL NOTES:
1. CONCRETE STRENGTH:
FTG - 2ND: fc' = 40 MPa
2ND - 3RD: fc' = 40 MPa
3RD - 4TH: fc' = 35 MPa
4TH - ROOF: fc' = 35 MPa
ROOF - PHR: fc' = 30 MPa
• MAXIMUM AGGREGATE SIZE IS 20mm UNLESS NOTED ON
COREWALL PLANS.
2. REINFORCING:
ALL WALLS TO BE REINFORCED AS FOLLOWS U/N ON DETAILED
DRAWINGS:
• 20M @ 100 H.E.F.
• 20M @ 350 V.E.F.
• 10-35M @ 150 VERT. +10M TIES @ 100 @ ENDS/EACH SIDE OF
DOORS/OPENINGS/CORNERS
• 4-20M T&B/E.S./E.F. OF MECH. OPENINGS U/N (EXTEND MIN. 600
PAST FACE OF OPENINGS)
• BEND VERTICALS INTO SLAB WHERE WALLS TERMINATE
• ALL LAPS TO BE CLASS `B' TENSION LAPS (MIN. 600, MIN. 1.5 d)
• WHERE WALLS INTERSECT SPACING OF CONCENTRATED
REINFORCING TO BE BASED ON GEOMETRY OF WALLS (AREA OF
CORE CREATED BY INTERSECTION). SPACE ALL OTHER VERT'S
AT SPACING NOTED.
3. GEOMETRY:
FDN - ROOF LEVEL: 350 (MIN.), 400 (MAX.) (SEE PLANS)
SEE COREWALL PLANS FOR DIMENSIONS. REFER TO ARCH.
4. WB1: 350/400x1600
10-25M T (3 LAYERS)
10-25M B (3 LAYERS)
15M @ 150 H.E.F.
2-10M STIRRUPS @ 100 o.c.
WB2: 200x1600
6-25M T (3 LAYERS)
6-25M B (3 LAYERS)
20M @ 100 H.E.F. (OR 150 @ UPPER FLOORS)
10M STIRRUPS @ 100 o.c.
(EXTEND HOR. BARS TO GRID 2&3)
SPACING
NOTED
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
COREWALL DETAILS: CW2
AS NOTEDS301COREWALL DETAIL CW2: FOOTING TO SECOND
SCALE 1:50
COREWALL DETAIL CW2: SECOND TO THIRD
SCALE 1:50
COREWALL DETAIL CW2: THIRD TO FOURTH
SCALE 1:50
COREWALL DETAIL CW2: FOURTH TO ROOF
SCALE 1:50
COREWALL DETAIL CW2: PENTHOUSE ROOF
SCALE 1:50
![Page 31: G E N E R A L N O T E S A N D D E T A I L S · steel stairs shall be designed and certified by the fabricator's professional engineer licensed in ontario in accordance with loads](https://reader036.vdocuments.mx/reader036/viewer/2022071220/605d0d7be950e27d5f6b74dc/html5/thumbnails/31.jpg)
MIN. 2-20M ADD'L
EACH FACE (U.N.O.)
DWLS TO MATCH VERTICALS
MECH. OPENINGS < 650x650
2-15M T&B/E.S./CORNERS ADD'L
(EXTEND 600 PAST EDGE OF OPENING)
(ALL OPENINGS NOT NOTED ON
STRUCTURAL DRAWINGS MUST BE
APPROVED BY ENGINEER IN WRITING
PRIOR TO CONSTRUCTION)
BEND VERTICALS INTO TOP OF
SLAB WHERE BARS
TERMINATE AT AN OPENING
VA
RIE
S (
24
00 M
AX
.)
CONCENTRATED REINFORCING
@ SIDES OF DOORS + WINDOWS (AS
PER PLANS/SCHEDULE)
>800
(UNO)
100
mm
(TY
P)
HOOK VERTICAL BARS INTO
SLAB AT TOP OF WALL
CONCENTRATED
REINFORCEMENT
EACH END OF WALL
S301
A
SCALE: N.T.S.
TYPICAL SHEARWALL & COREWALL REQUIREMENTS/
OPENING DETAILS (U/N)
DISTRIBUTED REINFORCEMENT
(VERTICAL & HORIZONTAL)
TYPICAL FLOOR LAPS:
CLASS `B' TENSION LAP (LAP
LENGTH BASED ON LARGER
BAR SIZE) (MIN. 1.3 d)
REINFORCING OVER OPENINGS
AS NOTED ON ELEVATIONS
HOOK HORIZONTAL BARS
AT END/OPENINGS AS PER
TYPICAL DETAILS
HOOK HORIZONTALS AT OPENINGS
AS PER TYPICAL DETAILS
DISPLACE DISTRIBUTED STEEL HOR/VERT.
E.S. OF OPENING (12 TO EACH SIDE)- INFILL SPACE WITH BARS OF MATCHING
SIZE/SPACING
10
0
FOOTING (SEE PLANS)
150 MAX.
U/N
TIES/HORIZONTAL
BARS IN SAME PLANE
HORIZONTAL BARS
ON INSIDE FACE
SPACING AS
NOTED ON PLANS
THICKNESS AS
PER PLANS
PLAN DETAIL: 2-10M TIES: 8 VERT. BARS
SCALE: N.T.S. @ WALL ENDS
PLAN DETAIL: TYPICAL REINFORCING LAYOUT
SCALE: N.T.S. @ WALL ENDS (Rd = 1.5)
CONCENTRATED REINFORCING STEEL LAYOUTS AND TYPICAL COREWALL DETAILS
PROVIDE 90° HOOK
@ END OF HORIZONTAL
BARS WHERE
B ≤ 800mm(32")
B
(UNLESS OTHER WISE NOTED ON SCHEDULES)
DETAIL: 2-10M TIES: 12 VERT. BARS
SCALE: N.T.S. @ WALL ENDS (6-V.E.F.)
DETAIL: TYPICAL REINFORCING LAYOUT
SCALE: N.T.S. @ WALL CORNERS (Rd=1.5)
PROVIDE 90° HOOKS ON
HORIZONTAL BARS. NOT
REQUIRED IF
B ≥ 800mm(32")
WHERE B ≥ 800mm(32")
PROVIDE ALTERNATE SHOWN:
MATCH HOR. BAR
SIZE/SPACING800(32")
80
0(3
2")
DETAIL: 2-10M TIES: 14 VERT. BARS
SCALE: N.T.S. @ WALL ENDS (7-V.E.F.)
S0
.5S
150 MAX.
U/N
150 MAX.
U/N
B0
.5S
S
DETAIL: 3-10M TIES: 16 VERT. BARS
SCALE: N.T.S. @ WALL ENDS (8-V.E.F.)
150 MAX.
U/N
DETAIL: 3-10M TIES: 18 VERT. BARS
SCALE: N.T.S. @ WALL ENDS (9-V.E.F.)
150 MAX.
U/N
DETAIL: 1-10M TIES: 6 VERT. BARS
SCALE: N.T.S. @ WALL ENDS (3-V.E.F.)
150 MAX.
U/N
SLAB (SEE PLANS)
SLAB (SEE PLANS)
CLA
SS
`B
'
TE
NS
ION
LA
P
(MIN
. 1.3
d
)
DISTRIBUTED VERTICAL/
HORIZONTAL REINFORCINGSFRS CLASSIFICATION:
CONVENTIONAL SHEAR WALLS
Rd = 1.5
Ro = 1.3
NO CRANKED BARS
S300
B
SCALE: N.T.S.
DETAIL: TYPICAL SHEARWALL & COREWALL REINFORCING
LAPS: CONCENTRATED STEELS300
C
SCALE: N.T.S.
DETAIL: TYPICAL FLOOR DOWELS/LAPS:
DISTRIBUTED STEEL
CLA
SS
`B
'
TE
NS
ION
LA
P
(MIN
. 1.3
d
)
0.5
t
t
15M @ 300 E.F.
900
900
COREWALL/SHEAR WALL NOTES:
1. CONCRETE STRENGTH:
FTG - 2ND: fc' = 40 MPa
2ND - 3RD: fc' = 40 MPa
3RD - 4TH: fc' = 35 MPa
4TH - ROOF: fc' = 35 MPa
ROOF - PHR: fc' = 30 MPa
• MAXIMUM AGGREGATE SIZE IS 20mm UNLESS NOTED ON
COREWALL PLANS.
2. REINFORCING:
ALL WALLS TO BE REINFORCED AS FOLLOWS U/N ON DETAILED
DRAWINGS:
• 20M @ 100 H.E.F.
• 20M @ 350 V.E.F.
• 10-35M @ 150 VERT. +10M TIES @ 100 @ ENDS/EACH SIDE OF
DOORS/OPENINGS/CORNERS
• 4-20M T&B/E.S./E.F. OF MECH. OPENINGS U/N (EXTEND MIN. 600
PAST FACE OF OPENINGS)
• BEND VERTICALS INTO SLAB WHERE WALLS TERMINATE
• ALL LAPS TO BE CLASS `B' TENSION LAPS (MIN. 600, MIN. 1.5 d)
• WHERE WALLS INTERSECT SPACING OF CONCENTRATED
REINFORCING TO BE BASED ON GEOMETRY OF WALLS (AREA OF
CORE CREATED BY INTERSECTION). SPACE ALL OTHER VERT'S
AT SPACING NOTED.
3. GEOMETRY:
FDN - ROOF LEVEL: 350 (MIN.), 400 (MAX.) (SEE PLANS)
SEE COREWALL PLANS FOR DIMENSIONS. REFER TO ARCH.
4. WB1: 350/400x1600
10-25M T (3 LAYERS)
10-25M B (3 LAYERS)
15M @ 150 H.E.F.
2-10M STIRRUPS @ 100 o.c.
WB2: 200x1600
6-25M T (3 LAYERS)
6-25M B (3 LAYERS)
20M @ 100 H.E.F. (OR 150 @ UPPER FLOORS)
10M STIRRUPS @ 100 o.c.
(EXTEND HOR. BARS TO GRID 2&3)
SPACING
NOTED
DRAWING No.
PROJECT No:
DATE:
SCALE:
DRAWN:
DRAWING
PROJECT
REVISIONS
STAMPPROJECT NORTH
No. DATE BY
The Contractor shall check and verify all dimensions on site.
This drawing is not to be used for construction unless
Do not scale drawings. Copyright reserved. This drawingis the exclusive property of Cleland Jardine Engineering Ltd.
stamped and signed by the Engineer.
1 DEC 17/15 ISSUED FOR PRELIMINARY FRAMING SH
TOMLINSON
NEW BUILDING
S.H.
B.J.
OCT. 2015
15-0179
APPROVED:
B.J./S.M./B.A.DESIGNED:
CLELAND
JARDINEENGINEERING LTD
2 JAN 22/16 ISSUED FOR 25% REVIEW SH
3 APR 7/16ISSUED FOR 25% REVIEW -
REVISED ATRIUMSH
4 APR 25/16 ISSUED FOR 33% REVIEW SH
5 MAY 17/16 SHISSUED FOR 50% REVIEW
6 MAY 31/16 SHISSUED FOR FOUNDATION PERMIT
7 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
PERMIT
8 JULY 7/16 JLISSUED FOR SUPERSTRUCTURE
TENDER
9 JULY 7/16 JLISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
10 JULY 14/16 SHRE-ISSUED FOR EXCAVATION/
FOUNDATION CONSTRUCTION
11 AUG 5/16 SHISSUED FOR BUILDING PERMIT
SHEAR WALL DETAILS
AS NOTEDS302