future generation for dc fast charging systems€¦ · • proprietary solutions for fast charging...
TRANSCRIPT
IAV 02/2017 UWt VT-E Vertraulich/Confidential
Future Generation for DC Fast Charging Systems
14. Braunschweiger Symposium Hybrid- und Elektrofahrzeuge
Ursel Willrett, Braunschweig, February 2017
1
Contents – DC Fast Charging Systems
IAV 02/2017 UWt VT-E Vertraulich/Confidential
Motivation
DC Charging Systems
Challenges for fast charging
systems
Approach for solutions
Summary
2
Status Quo „Charging connector“
IAV 02/2017 UWt VT-E Vertraulich/Confidential 3
Type 2 CCS CHAdeMO GB/T 20234
AC-Charger DC-Charger DC-Charger DC-Charger
Umax = 400 V,
3-phase
Umax = 850 V Umax = 600 V Umax = 750 V
Imax = 63 A Imax = 200 A Imax = 200 A Imax = 250 A
PConnector = 43,5 kW PConnector = 170 kW PConnector = 120 kW PConnector = 187,5 kW
Communication = PWM/PLC Communication = CAN
IAV 02/2017 UWt VT-E Vertraulich/Confidential 4
Tesla Supercharger
Tesla Super Charger (Power 120kW) Requires a proprietary connections only compatible with Tesla vehicles.Battery energies: 60 kWh .. 90 kWh
The Supercharger charges the batteries• In 30 minutes up to 50% SOC• in 45 minutes up to 80 % SOC • in 90 minutes battery completely charged
Source: www.teslamotors.com/de_AT/supercharger
Range (km)(30 minutes load time)
Load times
IAV 02/2017 UWt VT-E Vertraulich/Confidential 5
Minimal Standard Comfort
230V / 16A1 Phase
400V / 16A3 Phases
t = 8 h t = 3 h t = 2,0 h
400V / 32A3 Phases
P = 3,3 kW P = 11 kW P = 22 kW
Capacity of battery = 25 kWh, load time = Capacity of battery / charging power
AC Fast Charging
400V / 63A3 Phases
t = 1 h
P = 43,5 kW
DC Fast Charging
400V / 125ADC
t = 0,75 h
P = 50 kW
Charging Infrastructure – the next level
6IAV 02/2017 UWt VT-E Vertraulich/Confidential
Source: 19. Internationaler Fachkongress „Fortschritte in der Automobil-Elektronik“, Ludwigsburg, 23./24. Juni 2015
IAV 02/2017 UWt VT-E Vertraulich/Confidential 7
DC Charging System – Power supply
Performance of Power Supply relates on:
• Power supply access:
• low voltage
• medium voltage
• DC voltage access (i.e. electric tramway)
• Available nominal power (kW)
• Available power (kW) at a given time (load management, Smart Grid)
Plug EVCase CDC DC
DC Charging Station
Power supply Charging Station Load cable Electric vehicle
IAV 02/2017 UWt VT-E Vertraulich/Confidential 8
DC Charging System – Charging Station
Performance of charging station relates on:
• Maximum input power
• Technical conditions, i.e. size, weight, temperature control
• International standards (IEC 61851) specify 1000V, 200A maximum for output power of the charging station
Source: IAV
Plug EVCase CDC DC
DC Charging Station
Power supply Charging Station Load cable Electric vehicle
IAV 02/2017 UWt VT-E Vertraulich/Confidential 9
DC Charging System – Load cable
Performance of load cable relates on:
• Technical conditions, i.e. size, weight, maximum temperature of the connectors
• International standards (IEC 62196) specify 850V, 200A maximum for power of the load cable
Source: www.phoenixcontact.de
Plug EVCase CDC DC
DC Charging Station
Power supply Charging Station Load cable Electric vehicle
IAV 02/2017 UWt VT-E Vertraulich/Confidential 10
DC Charging System – Electric vehicle
M
High voltage battery
• Technical conditions: number of cells, connections of the cells -> (V,I), size, weight
• Battery technology
Power electronic unit, electric engine
• Technical conditions: (V,I), size, weight
Harness, connectors, fuses, contactors, sensors
• Technical conditions: (V,I), size, weight
• Availability of the components related on selected (V,I) for automotive conditions
11
Load times - Relations
Load time: � = �
�
Power [kW] Load time [min]
50 24
170 7W=20 kWh
� = � ∗ �
Power Loss ?
Maximum Voltage?
Maximum Current?
Maximum Weight?
Maximum Size?
Medium voltage access – example Tesla Supercharger
IAV 02/2017 UWt VT-E Vertraulich/Confidential 12
Medium voltage access(15kV)
Transformer(P up to 1MVA)
TeslaSuperchargerDistribution/
SafetyTesla
Charging Tower
L1
L2
L3
N
PE
Power supply Charging Station Load cable Electric vehicle
High power charging station - Example
IAV 02/2017 UWt VT-E Vertraulich/Confidential 13
Power supply Charging Station Load cable Electric vehicle
Power: 45 / 90 / 150 kW
Voltage: 50 to 920 V (1.000 V)
Current: 0 to 200 A
Communication: IEC61851-23
PLC (CCS / Combo-2)
Connector: Combo T2
(CCS / Combo-2)
Dimensions: 1000 x 800 x 1800 mm
(at 150 kW)
Source: electricmobility.efacec.com/ev-qcbus
Load Cable – Fast Charging up to 350A
IAV 02/2017 UWt VT-E Vertraulich/Confidential 14
• The available standards provide 200A charging current at 850V charging voltage without cooling. (IEC 62196-3)
• The proposed extension in the charging plug with the cooling circuit the max. charging current increases to 350A.
• Requirement of the standard, dT <=50K, is full-filled with the solution.
• Charging power of more then 300kW for the load cable is achievable.
Power supply Charging Station Load cable Electric vehicle
Source: www.phoenixcontact.de
HV-Battery Storage
IAV 02/2017 UWt VT-E Vertraulich/Confidential 15
• The total HV-battery voltage Vbatt is given by the number of cells in series.
• The maximum charging current is determined by the number of parallel circuits.
• The maximum current for each circuit is limited by the cell parameter (maximum current).
• Charging power P is equal to the product of V and I.
• Charging with high power impacts the life time of the battery.
HV-Battery, p parallel parts
S cells in series
Vbatt
I
�� = ���� ∗ ��
� � = �
��� � =
�� ∗ � ∗ �
� ∗ �� ∗ � ∗ ��� � =
��
�� ∗ ��
Using cell parameters from the data sheet of the selected cell the minimum achievable load time of the HV-battery is calculated by:
Power supply Charging Station Load cable Electric vehicle
W: battery capacityWz: cell capacityS: number of cells in seriesP: number of cells parallelVz: voltage of cell Iz: maximum continuous current of the cell
Estimation of power loss of a 400V HV-Battery during charging process
IAV 02/2017 UWt VT-E Vertraulich/Confidential 16
�� = � ∗�
����+ ����
�� = � ∗(�� − ����)
����
� = �
�
Source: IAV
IAV 02/2017 UWt VT-E Vertraulich/Confidential 17
Performance related to use cases
Use Case Batteryconnection
Max.continuoscharg. current
Max. Batteryvoltage
Max. chargingpower
Power loss
Batterymass
Range Load time90%
Load time100 km
Available EV 90s 3p 120 A 350 V 42 kW 0,78 kW 318 kg 130 km 30 min 20 min
Increased
charging current
90s 3p 200 A 350 V 70 kW 2,16 kW 318 kg 130 km 18 min 12 min
Max. battery size
(medium size
passenger car)
220s 2p 180 A 855 V 154 kW 6,52 kW 527 kg 191 km 14 min 5,49 min
Power optimized
cell
354s 2p 250 A 1380,5 V 358,2 kW 20,34 kW 850 kg 265 km 10,5 min 2,54 min
1. Available electric vehicle, medium size passenger car
2. Available electric vehicle, increased charging current
3. Battery increased to the maximum regarding size and weight (based on medium sizepassenger car)
4. Charging with 350 kW
IAV 02/2017 UWt VT-E Vertraulich/Confidential 18
Maximal charging power >170 kW
• Extensions of existing standards required (i.e. IEC 61851, IEC 62196)
• All components of the fast charging system can be extended to provide the respective performance features.
• Proprietary solutions for fast charging systems can be used by a sub-set of users only -> therefore they are not appropriate to ensure long-term business success
• Intelligent upgrading is performed -> DC fast charging only if required!
Plug EVCase CDC DC
DC Charging Station
Power supply Charging Station Load cable Electric vehicle
Summary and Prospect
IAV 02/2017 UWt VT-E Vertraulich/Confidential
• Available international standards already enable development of DC fast charging up to 170 kW.
• Fast charging systems today perform charging power up to 60kW with standardized solutions, Tesla Super Charger provides 120kW.
• Technical extension to charging power until 170kW and beyond is feasible with existing technologies:
– Power supply: Medium voltage access
– Charging station: high power fast DC Charger
– Load Cable: connectors, cooling features
– Electric vehicle: HV-Battery increase, adaptation of HV vehicle components
• For proper roll-out of charging systems >170kW extensions of the international standards are required.
Future generations for DC Fast Charging Systems is feasible even with todays technologies .
Intelligent upgrade where needed according to user benefit and business case.
19
Thank You
Ursel WillrettInfrastructure Systems E-Mobility
Tel. +49 7031 [email protected]
www.iav.com
IAV 02/2017 UWt VT-E Vertraulich/Confidential 20