full composite epoxy sleeve designed for the strengthening...
TRANSCRIPT
• Technologically advanced• Online Installation• Cost effective• Verified as per ASME PCC-2
Full Composite Epoxy Sleeve Designed For The Strengthening And Protection Of Pipelines
Combining the Best of both Epoxy Sleeve Repairs and Composite Wrapping Techniques
SECTIONAL CUT OUT DETAIL
Polyamide End Cap
Interlocking PE or PTFE Sleeve
Carbon FibreReinforcement
Grout Fill
HELICOID Epoxy Sleeve TM Technology that is simply the best
FULL COMPOSITE EPOXY SLEEVE DESIGNED FOR THE STRENGTHENING AND PROTECTION OF RISERS AND SUB SEA PIPELINES
The Helicoid Epoxy Sleeve ™ is a helically wound, carbon �bre reinforced, mechanically interlocking PE or PTFE strip, allowing an annulus of approximately 25 to 35 mm around the pipe to be �lled with an epoxy or cementatious grout, therewith giving outstand-ing strengthening and protection qualities The Helicoid Epoxy Sleeve™ has been designed, tested and certi-�ed in accordance with the ASME PCC-2 and is an approved repair system under the ASME 31.4 and ASME 31.8 for repairs of external wall thinning, dents and gouges The sleeve can be installed to risers, up to 3.0 m below MSL, completely diverless, in diameters between 150 mm to 600 mm and up to a length of 10.0 m in one single application, without the shut down of the facilities
Bene�ts Of Helicoid
Epoxy Sleeve TM
Pre-engineered
O�-the-shelf
Diameters between 150mm to 600mm
Length up to 10.0m
For strengthening and protection
On-line installation
Above water and subsea installation
Diverless riser installation
Corrosion resistant
Impact resistant
Temperatures up to 120 degrees Celsius
Easy and fast installation
Durable
Marine growth resistant
Cost e�ective
Multiple sleeves to accommodate
extended length
Independent third party veri�cation
by Lloyd’s Register and tested in acco-
dance with ASME PCC-2-2006,
“Repair of Pressure Equipment and Piping”
Main Characteristics
Reinforcement properties Fibre nature : Carbon �ber, Torayca T700 SC
Fibre direction: uni-directional, pultruded
Flexural Strength ( ASTM D 790) :1480 N/mm2
Flexural Modulus (ASTM D 790) : 89000 N/mm2
Tensile Strength (ASTM D 3039) : 2350 N/mm2
Tensile Modulus( ASTM D3039) :140,000N/mm2
Elongation at break (ASTM D 3039) : 0.8 %
Poisson Ratio : 0.2
Density : 1750 kg/m3
Grout Properties Chemical family : Epoxy
Compressive Strength ( ASTM C 109) : 100 N/mm2
Compressive Modulus ( ASTM C 109 ) : 2100 N/mm2
Flexural Strength ( ASTM D 790) : 26 N/mm2 @ 7 days
Tensile Strength (ASTM D 638) :14 N/mm2 @ 7 days
Coe�. of Therm. Exp. ( ASTM D 351) : 28.1 x10 3
Bond Strength to Steel ( UW) (ASTM D 4541) >10.5 MPa
Heat De�ection Temp ( ASTM D 648) : 83 degrees C
PE Strip Properties Tensile Strength ( ASTM D 638) : 28 N/mm2
Flexural Modulus ( ASTM D 790) : 1400 N/mm2
Izod Impact ( ASTM 256) 0.07 Joules/mm of Notch
Heat De�ection Temperature (ASTM D 648) : (@ 0.5N/mm2) : 78 degrees C
Water Absorption ( ASTM D 570 ) : 0.10 %
Coe�. of Lin. Therm. Exp. (ASTM D 696 ) : 3.85 mm/mm/degrees C x 10-5
2. Winding of sleeve continued to full required length
1. Installation of winding cage
3. Epoxy grout injection procedure 4. Cut out shows epoxy grout injection into sleeve annulus
5. Helicoid sleeve repair complete 6. Sleeve repair procedure repeated along pipeline as required
Typical Installation Sequence on Sub Sea Pipeline
2. Insertion of Polyethylene strip to commence winding of sleeve
1. Installation of winding cage
3. Attachment of polyamide caps
4. Sleeve is wound to full required length
5. Injection of epoxy grout 6. Helicoid sleeve repair complete
Typical Installation Sequence on Riser ( Riser Splash Zone Area )
Lloyd's Register’s test certi�cates can be made available upon request
YOUR ASSURANCE IN STRENGTH AND PROTECTION
Surface Preparation Of Riser
As part of the installation of the sleeve, a system has been developed for the removal of marine growth, neoprene liners and coatings of up to 3.00 m below MSL, without the intervention of divers The lightweight, modular equipment can be installed by a crew of 2 technicians and is capable of achieving surface cleanliness of up to Swedish Standard SA 2.5 by means of high pressure water - and abrasive blasting The level of cleanliness can be monitored from the top deck through attached CCTV cameras
1. Installation of riser cleaning equipment 2. Surface preparation of riser
4. Cleaning of riser below water to required depth
3. Cleaning of riser above water to required length
6. Completion of surface preparation5. Cleaning under water
Preliminary Riser Surface Preparation
Simply The Best Pipeline Strengthening & Protection System.
Merit Technologies Sdn Bhd(comp. no. 655607-U)
No. 8, Jalan PJU 3/45,Sunway Damansara Technology Park,47810 Petaling Jaya,Selangor Darul Ehsan,Malaysia