Flow Cytometry and Reproducible Analysis. Cliburn Chan Department of Biostatistics and Bioinformatics, DUMC. Reproducible Analysis. Can someone in a different lab replicate your results? Can someone else in your lab replicate your results? Can you replicate your own results 6 months later? - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Flow Cytometry and Reproducible Analysis

Flow Cytometry and Reproducible Analysis

Cliburn ChanDepartment of Biostatistics and

Bioinformatics, DUMC

Page 2: Flow Cytometry and Reproducible Analysis

Reproducible Analysis

• Can someone in a different lab replicate your results?

• Can someone else in your lab replicate your results?

• Can you replicate your own results– 6 months later?– When FlowJo goes from version 10.0 to 11.0?– When your lab catches fire and all your computers

melt into toxic waste?

Page 3: Flow Cytometry and Reproducible Analysis

Complexity of flow analysis

• Experimental design• Running the experiment• Raw data (FCS files)• Compensation• Transformation• Gating strategy• Gates MFI and relative frequencies• Statistical analysis – e.g. outcome correlation

Page 4: Flow Cytometry and Reproducible Analysis

Experimental design

• Is randomization done correctly?• Is the sample size sufficient?• Is there an SOP for annotating the experiment?– MIATA– MiFlowcyt

• What is the informatics strategy to ensure that data is recorded accurately and backed-up safely?

Page 5: Flow Cytometry and Reproducible Analysis

Running the experiment

• Stuff I know little about …• Janet and Jennifer will teach in this workshop– Instrument calibration– Bridging studies– Reagent qualification– Use of appropriate biological controls– Use of appropriate technical controls

Page 6: Flow Cytometry and Reproducible Analysis

Raw data (FCS files)

• Is there a file naming SOP that is followed?• Is there an SOP for recording FCS metadata?– Channel labels – fluorochrome, antibody, FMO

Page 7: Flow Cytometry and Reproducible Analysis

Inconsistent annotation example

Page 8: Flow Cytometry and Reproducible Analysis

Compensation, transformation and gating strategy

• Compensation is Real = Spillover-1 × Observed• Transformation is complicated – can think of as

linear (low values) and log (high values)• Gating strategy is hard to replicate, but can be

stored as a template and “re-used” with tweaking• Compensation, transformation and gating should

be done on a per-batch and not per-file basis• Would recommend storing workspace containing

this data in both .jo and .xml formats

Page 9: Flow Cytometry and Reproducible Analysis

Working with statisticians

• At some point, a statistician is likely to be asked to analyze your data. This can lead to much unhappiness.

• Statisticians do not like Excel– The first thing they will try to do is export to a CSV

or delimited file, for import into SAS or R– If this is difficult to do, they will not like you

Page 10: Flow Cytometry and Reproducible Analysis

Excel rules for happy statisticians

• 1 worksheet = 1 table• 1 cell = 1 value• Data/metadata = comprehensive & consistent• Formatting = None• Validation = Yes

Page 11: Flow Cytometry and Reproducible Analysis

1 worksheet = 1 table

• A table has column headers and a number of rows and nothing else – it is RECTANGULAR

• Do not put more than 1 table in a worksheet• Do not use non-rectangular tables• Example of good worksheet

Page 12: Flow Cytometry and Reproducible Analysis

1 worksheet = 1 table

Page 13: Flow Cytometry and Reproducible Analysis

1 cell = 1 value

• Easy to filter by tube, sample or subject• Easy to write validation rules or lookup table

Page 14: Flow Cytometry and Reproducible Analysis

1 cell = 1 value

• ID column has 3 different values• Need to do text parsing to recover information

– very error prone

Page 15: Flow Cytometry and Reproducible Analysis

Data: column names

• Consistent column names across worksheets– Singlets/Lymphocytes– Singlet/Lymphs– Singlets / Lymphocytes– Singlets/Lymphoctyes

• Use full gating path for column name– Singlets/Lymphocytes/Viable/CD4+/CM/IFN+

Page 16: Flow Cytometry and Reproducible Analysis

Data: What to record

• Better to have more data than less data– Sample type (PBMC, whole blood)– Recovery – Viability

• Better to have basic than derived data– Counts better than relative frequencies

• Keep link to raw data for reproducibility– Path to FCS and workspace files on server

• Use special indicator for missing data (e.g. NAN), not zero• Use as many columns as you need and name them sensibly

and consistently

Page 17: Flow Cytometry and Reproducible Analysis

Data: Versioning

• Do not change the data in the worksheet once it has been handed to statistician.

• If there are errors that must be corrected, make a new copy, label the filename with date and version, and send that to statistician– ArcticRatExperiment_07May2013_Version01.xlsx– ArcticRatExperiment_17May2013_Version02.xlsx

Page 18: Flow Cytometry and Reproducible Analysis

Formatting

• Don’t do it.• Avoid putting information via:– Highlighting– Fancy spacing– Different fonts and font effects– Merging cells– Comments

• Will it survive a round-trip from Excel to CSV and back again?

Page 19: Flow Cytometry and Reproducible Analysis

Formatting - Before

Page 20: Flow Cytometry and Reproducible Analysis

Formatting - After

Comments are lostHighlighting is lostBad cell formatting is lostMerged cells become missing information

Page 21: Flow Cytometry and Reproducible Analysis

Summary of Reproducible Analysis

• Know what you are doing from PBMC to Excel• SOPs are important• Annotation is important• Excel is OK if you use NONE of its features • Keep all necessary data in the same place• Keep a remote backup• Talk with your statistician

Page 22: Flow Cytometry and Reproducible Analysis

Biologist talks to Statistician