Select Language Applications Systems About Firetrace Contact Industrial Applications Cleaning Tanks Computer and Server CNC Machines Dust & Mist Collectors Electrical Control Cabinets EDM Machine Fire Protection Fume Hoods & Cabinets for Labs Hazardous Material Storage Manufacturing Telecommunications Equipment Wind Turbines On Road Vehicles Off Road Vehicles Facilities Locating the Firetrace tubing on the ram of the EDM allows for faster detection and suppression. EDM Machine Fire Protection Machine-level protection for your critical assets View diagram Tight margins and tight schedules are forcing many plant managers with EDMs to run machines with reduced staff. In spite of the many safety features on modern EDM equipment, fires that can destroy a machine or possibly spread through an entire machine shop, still do jeopardize workers' safety. Fires in EDM machines frequently result from a drop in oil level or other anomalies. When this occurs, the ready supply of coolant oil and oil vapor can turn a small spark into a major fire in moments. Firetrace's proprietary red Firetrace Detection Tubing (FDT) can be located unobtrusively on the ram to hover just above the oil surface. This placement offers detection right at the source of the threatened area. This tubing, due to its proximity to the source of the fire, typically responds many times faster than a traditional sprinkler head. In the event of a fire the tubing ruptures instantly starting the CO2 or FM-200 clean agent system discharge. A large nozzle delivers a gentle, yet effective, flow of agent to suppress the fire. The deployment of this agent is critical as more forceful flows can cause the burning oil to splash or splatter resulting in spreading rather than extinguishing the fire. Firetrace also offers options for manual activation and automatic machine shutdown in the event a fire is detected. Firetrace is also an effective fire protection solution for oil / mist collection systems. Already in use on more than 5,000 EDM and screw machines and with countless reports of successful fire suppressions Firetrace's EDM machine fire systems are a reliable and cost-effective solution for machine shop fire protection! Download General Brochure Brochures CNC Brochure Articles EDM Fire Suppression Considerations EDM Today Article on Fires © Firetrace International, LLC., 15690 N. 83rd Way, Suite B, Scottsdale, AZ 85260 USA MSDS | Distributor Information | Brochures

Upload: hy-test-inc

Post on 07-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

Download General Brochure Brochures Fires in EDM machines frequently result from a drop in oil level or other anomalies. When this occurs, the ready supply of coolant oil and oil vapor can turn a small spark into a major fire in moments. This placement offers detection right at the source of the threatened area. This tubing, due to its proximity to the source of the fire, typically responds many times faster than a traditional sprinkler head. Articles CNC Brochure View diagram Select Language

TRANSCRIPT

Page 1: Firetrace_ Applications - Edm Machine Fire Protection

Select Language

Applications Systems About Firetrace Contact

Industrial ApplicationsCleaning TanksComputer and ServerCNC MachinesDust & Mist CollectorsElectrical Control CabinetsEDM Machine FireProtectionFume Hoods & Cabinetsfor LabsHazardous MaterialStorageManufacturingTelecommunicationsEquipmentWind TurbinesOn Road VehiclesOff Road VehiclesFacilities

Locating the Firetrace tubing on theram of the EDM allows for fasterdetection and suppression.

EDM Machine Fire ProtectionMachine-level protectionfor your critical assets

View diagram

Tight margins and tight schedules are forcing many plant managers with EDMsto run machines with reduced staff.

In spite of the many safety features on modern EDM equipment, fires that candestroy a machine or possibly spread through an entire machine shop, still dojeopardize workers' safety.

Fires in EDM machines frequently result from a drop in oil level or otheranomalies. When this occurs, the ready supply of coolant oil and oil vapor canturn a small spark into a major fire in moments.

Firetrace's proprietary red Firetrace Detection Tubing (FDT) can be locatedunobtrusively on the ram to hover just above the oil surface.

This placement offers detection right at the source of the threatened area. Thistubing, due to its proximity to the source of the fire, typically responds manytimes faster than a traditional sprinkler head.

In the event of a fire the tubing ruptures instantly starting the CO2 or FM-200clean agent system discharge. A large nozzle delivers a gentle, yet effective,flow of agent to suppress the fire. The deployment of this agent is critical asmore forceful flows can cause the burning oil to splash or splatter resulting inspreading rather than extinguishing the fire.

Firetrace also offers options for manual activation and automatic machineshutdown in the event a fire is detected. Firetrace is also an effective fireprotection solution for oil / mist collection systems.

Already in use on more than 5,000 EDM and screw machines and with countlessreports of successful fire suppressions Firetrace's EDM machine fire systems area reliable and cost-effective solution for machine shop fire protection!