final focus: combination of pre isolator and active stabilisation

27
FINAL FOCUS: COMBINATION OF PRE ISOLATOR AND ACTIVE STABILISATION K. Artoos, C. Collette, R. Leuxe, C.Eymin, P. Fernandez, S. Janssens * The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures project EuCARD

Upload: ayasha

Post on 23-Feb-2016

26 views

Category:

Documents


0 download

DESCRIPTION

K. Artoos, C. Collette, R. Leuxe, C.Eymin , P. Fernandez , S. Janssens *. Final focus: Combination of pre isolator and active stabilisation. The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures project EuCARD. Outline. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Final focus: Combination of pre isolator and active stabilisation

FINAL FOCUS: COMBINATION OF PRE ISOLATOR AND ACTIVE STABILISATION

K. Artoos, C. Collette, R. Leuxe, C.Eymin, P. Fernandez, S. Janssens*

The research leading to these results has received funding from the European Commission under the FP7 Research Infrastructures project EuCARD

Page 2: Final focus: Combination of pre isolator and active stabilisation

2

Outline

S. Janssens, P. Fernandez, A&T Sector Seminar, Geneva, 24 November 2011

How to perform active control on the preisolator to damp the 1 Hz resonance

Issues with using the preisolator as it is Further research proposal Question about accelerometer feedback

Page 3: Final focus: Combination of pre isolator and active stabilisation

3

Preisolator

m=50ka=480e6ξ=0.01 Mp =40000fp =1 Hz ξp=0.01

What is needed to damp/influence peak of pre-isolator mode?

Perfect feedback (no filtering and sensors)

Page 4: Final focus: Combination of pre isolator and active stabilisation

4

Active Isolation Strategies

Add virtual mass

Feedback control principle

Page 5: Final focus: Combination of pre isolator and active stabilisation

5

Active Isolation Strategies

Sky-hook damper (D.C. Karnopp, 1969)

Feedback control principle

Page 6: Final focus: Combination of pre isolator and active stabilisation

6

Active Isolation StrategiesFeedback control principle

S. Janssens, P. Fernandez, A&T Sector Seminar, Geneva, 24 November 2011

Virtual stiffness added

Page 7: Final focus: Combination of pre isolator and active stabilisation

7

Active Isolation Strategies

Closed Twx

10-10

10-5

100

Mag

nitu

de (a

bs)

10-1 100 101 102 103 104-360

-270

-180

-90

0

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

Control onControl off

10-2

100

102

104

Mag

nitu

de (a

bs)

10-1 100 101 102 103 104-180

-135

-90

-45

0P

hase

(deg

)

Bode Diagram

Frequency (Hz)

Preisolator mode

Top mass mode

Reduces transmissibilityDoesn’t damp first modeAlways stableAuthority at 1 Hz needed with factor 100

Qd0 stabilization system as it isPosition feedback

Page 8: Final focus: Combination of pre isolator and active stabilisation

8

Active Isolation Strategies

10-10

10-5

100

Mag

nitu

de (a

bs)

10-1 100 101 102 103 104-360

-270

-180

-90

0

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

control offcontrol on

Preisolator mode

Top mass mode

Reduction of transmissibilityNo damping of the modeTop mass mode doesn’t move (as no added stiffness due to ff)Authority at 1 Hz needed with factor 100

QD0 stabilization as it isFeedforward of

Page 9: Final focus: Combination of pre isolator and active stabilisation

9

Active Isolation Strategies

10-10

10-5

100

105

Mag

nitu

de (a

bs)

10-1 100 101 102 103-360

-270

-180

-90

0

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

control offcontrol on

10-4

10-2

100

102

Mag

nitu

de (a

bs)

10-1 100 101 102 103 104-90

-45

0

45

90P

hase

(deg

)

Bode Diagram

Frequency (Hz)

Preisolator mode

Top mass mode

Closed TwxOnly effect on second modeAlways stable(similar results with IFF+noise issue)

Damping with velocity feedback

Page 10: Final focus: Combination of pre isolator and active stabilisation

10

Active Isolation Strategies

10-20

10-10

100

1010

Mag

nitu

de (a

bs)

10-2 10-1 100 101 102 103 104 105 106-360

-270

-180

-90

0

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

Control offControl on

Preisolator mode

Top mass mode

Closed TwxDoesn’t work as it just injects noise due to phase difference

Velocity feedforward

Page 11: Final focus: Combination of pre isolator and active stabilisation

11

Active Isolation Strategies

10-10

10-5

100

105 From: In(3)

To: O

ut(2

)

10-1 100 101 102 103 104 105 106-90

-45

0

45

90To

: Out

(2)

Bode Diagram

Frequency (Hz)

Mag

nitu

de (a

bs) ;

Pha

se (d

eg)

Proposed velocity feedback of Damps first mode critically

Page 12: Final focus: Combination of pre isolator and active stabilisation

12

Active Isolation Strategies

Damps the peak and reduces transmissibility

Combination of and feedback

Page 13: Final focus: Combination of pre isolator and active stabilisation

13

Issues for the preisolator3D coherence of ground motion

C. Collette, ILC-CLIC LET Beam Dynamics Workshop (23-25 June 2009)

Measurements performed in LHC tunnel by K. Artoos and M. Guinchard.

Ground motion > 12 m @ 1 Hz is not coherent

=> Active damping and transmissibility reduction necessary at 1 Hz

Page 14: Final focus: Combination of pre isolator and active stabilisation

14

Issues for the preisolator

+pressure on vertical plane on surface of magnets which has a moment arm!! +other noise sources coming from the detector=> Increasing with position feedback necessary!

Page 15: Final focus: Combination of pre isolator and active stabilisation

15

Issues for the preisolator15

J. Pfingstner

Preliminary max roll simulations vs luminosity loss=> Max 1 μrad!

Page 16: Final focus: Combination of pre isolator and active stabilisation

16

Further simulations with PID

More complex model has been made

With PID feedback for =>improved position, damping and compliance

With proposed CERN MBQ stabilization (as example)

Page 17: Final focus: Combination of pre isolator and active stabilisation

Further simulations with PID

Possible transfer function between ground and QD0 + no drift at low freqPossibility to change Preisolator position!!!No noises or filters in it!!!!

Page 18: Final focus: Combination of pre isolator and active stabilisation

Further Research proposal (tender/inhouse)

More complex model=>Investigate modes with changing magnet positions

Page 19: Final focus: Combination of pre isolator and active stabilisation

Further Research proposal (tender/inhouse)

Research goals1. Make a dynamic model of the system presented. For this model:

• give the transfer functions between all degrees of freedom and the ground• make a table of all the modal frequencies and their decomposition in eigenvectors• graphical representation of the evolution of the modal frequencies and their decomposition

for a changing γ from 0 up to 15 degrees which changes the position of mg,mQF1, mst, mstb, mQD0.• What is the effect of increasing the 1st mode to 20 Hz?

2. Propose the best active damping (velocity feedback, Integrated Force Feedback,…) system which:• damps the 1st mode of Mpi critically• Reduces the 1st mode from 20 Hz to 1 Hz through active control• uses existing technologies compliant with the environmental parameters,• does decrease the drop off above 2ωpi in the transfer function between wpi and xpi,

for the ground vibrations specified, due to noise or any other limitations (actuator or sensors).• Specify the number actuators/sensors (The 4 specified are a suggestion).• Is it better to use a global controller or have each leg have its own SISO controller

and decouple them with joints?• Simulate the performance of the proposed isolation system in an environment with

ground vibrations and applying actual sensor/actuator, sensitivity, noise and resolution.

~2 months

~5 months

Page 20: Final focus: Combination of pre isolator and active stabilisation

Further issues The alignment stage (would fall off now) Effect of the 2nd and 3rd mode on

luminosity Effect of phase difference between two

preisolator blocks Further issues?

Page 21: Final focus: Combination of pre isolator and active stabilisation

Question accelerometer feedback

101

102

10-3

10-2

10-1

100

101

102

Frequency [Hz]

T_{e

ndev

co/g

eoph

one

int acc vs T6int acc vs L4C

Measured sensitivity endevco M86

Sensitivity curve of accelerometer has resonance at ~200-300 Hz

->issue with stability when resonance of system and accelerometer meet

Page 22: Final focus: Combination of pre isolator and active stabilisation

Question accelerometer feedback

10-4

10-2

100

102

104

Mag

nitu

de (a

bs)

101 102 103-360

-180

0

180

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

Openloop acc pos fbOpenloop acc vel fbOpenloop acc acc fb

system modemode accOpenloop:Stable if for Mag>1Phase -180<phi<180

System mode high:Acc fb okVel fb unstable Could be made stablePos fb unstable Could be made stable

Openloop cut

Page 23: Final focus: Combination of pre isolator and active stabilisation

Question accelerometer feedback

10-4

10-2

100

102

104

Mag

nitu

de (a

bs)

101 102 103-360

-180

0

180

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

Openloop acc pos fbOpenloop acc vel fbOpenloop acc acc fb

accmodesystem mode

Pole cancellation -> very good knowledge of system necessary, difficult for complex system -> acc mode needs to be far away from system modes

System mode low:Acc fb okVel fb unstablePos fb unstable Only pole cancellation

Page 24: Final focus: Combination of pre isolator and active stabilisation

ConclusionActive control of the preisolator block is needed:-to perform damping of the resonance-to provide positioning/alignment capabilities/synchronize with other preisolator-to improve compliance of the system

Proposed solution for a PID on the preisolator

Further study required with full model=> Tender/inhouse study?

Stef’s learning moment about accelerometer feedback

Page 25: Final focus: Combination of pre isolator and active stabilisation

Spares

Page 26: Final focus: Combination of pre isolator and active stabilisation

Pre-isolator feedbackacc fb

10-10

10-5

100

105 From: In(2)

To: O

ut(1

)

10-1 100 101 102 103-360

-270

-180

-90

0

To: O

ut(1

)

Bode Diagram

Frequency (Hz)

Mag

nitu

de (a

bs) ;

Pha

se (d

eg)

Control offControl on (acc fb)

Closed Twx

10-10

10-5

100

105

Mag

nitu

de (a

bs)

10-1 100 101 102 103 1040

45

90

135

180

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

Preisolator mode

Top mass mode

Only effect on second modeAlways stable

Page 27: Final focus: Combination of pre isolator and active stabilisation

10-20

10-10

100

1010

Mag

nitu

de (a

bs)

10-2 10-1 100 101 102 103 104 105 106-360

-270

-180

-90

0

Pha

se (d

eg)

Bode Diagram

Frequency (Hz)

controll offcontrol on

Pre-isolator feedbackacc ff

Closed Twx

Preisolator mode

Top mass mode

Doesn’t work!