filter final
TRANSCRIPT
-
7/29/2019 Filter Final
1/23
Flows from 20 to 21,250 scfm (34 to 36.119 m3
/h)Maximum working conditions of 300 psig &
150F (21 bar, 66C)
HF Series Compressed Air FiltersHF Series Compressed Air FiltersHF Series Compressed Air FiltersHF Series Compressed Air Filters
-
7/29/2019 Filter Final
2/23
HF Series Filters
The ObjectiveThe ObjectiveThe ObjectiveThe Objective
To meet and exceed the global demand for:
Energy Savings
Product Communication
Quality & reliability
-
7/29/2019 Filter Final
3/23
HF Series Filters
Hankison Quality isHankison Quality isHankison Quality isHankison Quality isBuilt into Every HousingBuilt into Every HousingBuilt into Every HousingBuilt into Every Housing
Epoxy coated interior and exterior
Threaded discharge connection
Bayonet head to bowl connectionup to 170 scfm (289 m3/h)
Thermoset polyurethane liquid level indicator
Every housing tested to a 5:1 factor of safety
-
7/29/2019 Filter Final
4/23
HF Series Filters
All stainless steel inner and outer cores
Complete seam welded cores having aburst pressure of 65 psid (4.5 bar)
Coated foam sleeves providing protectionagainst chemical attacks
100% silicone free
Hankison Quality is BuiltHankison Quality is BuiltHankison Quality is BuiltHankison Quality is Builtinto Every Filter Elementinto Every Filter Elementinto Every Filter Elementinto Every Filter Element
-
7/29/2019 Filter Final
5/23
HF Series Filters
Complete Filter OfferingComplete Filter OfferingComplete Filter OfferingComplete Filter Offering
Seven grades of filtration allow systems tobe precisely customized
Each element grade is tested to
international standards
-
7/29/2019 Filter Final
6/23
HF Series Filters
Grade 11Grade 11Grade 11Grade 11 ---- Bulk Liquid SeparatorBulk Liquid SeparatorBulk Liquid SeparatorBulk Liquid Separator
A labyrinth style flow path removes liquid
water from the air stream by forcing abrupt
directional changes
Liquid water impinges on the walls of theinternal cores while the air stream flows
easily through the labyrinth, providing
minimal pressure losses
Efficient to 5% of rated flow
Removes up to 30,000 ppm liquid
contamination at efficiencies greater
than 90%
-
7/29/2019 Filter Final
7/23
HF Series Filters
Grade 9Grade 9Grade 9Grade 9 ---- Separator/FilterSeparator/FilterSeparator/FilterSeparator/Filter
99% efficient at removing up to 25,000 ppm
liquid water from an air stream
In-depth coalescing bed captures solid and
liquid contaminates 3 micron in sizeand larger
-
7/29/2019 Filter Final
8/23
HF Series Filters
Grade 7Grade 7Grade 7Grade 7 ---- Air Line FilterAir Line FilterAir Line FilterAir Line Filter
Coarse coalescing filter capable of providing
ISO 8573.1 class 2 solid and class 3 oil
content air
Captures and removes particles 1.0 micronand larger in size
Remaining oil content as low as 1.0 mg/m3
Extends life of fine coalescing Filters
-
7/29/2019 Filter Final
9/23
HF Series Filters
Grade 6Grade 6Grade 6Grade 6 ---- DesiccantDesiccantDesiccantDesiccant AfterfilterAfterfilterAfterfilterAfterfilter
Designed to remove solid particles down to
1.0 micron in size in a dry air flow
Long life afterfilter for heatless
desiccant dryers
Outside/in flow, extends the usable life of
the filter
-
7/29/2019 Filter Final
10/23
HF Series Filters
Grade 5Grade 5Grade 5Grade 5 ---- High EfficiencyHigh EfficiencyHigh EfficiencyHigh EfficiencyCoalescing Oil Removal FilterCoalescing Oil Removal FilterCoalescing Oil Removal FilterCoalescing Oil Removal Filter
Capable of providing ISO 8573.1 class 1
Solid and Class 1 oil content air quality
Captures 99.99+% of all oil aerosols
Reduces oil aerosol content to 0.008 ppm
(0.01 mg/m3)
-
7/29/2019 Filter Final
11/23
HF Series Filters
Grade 3Grade 3Grade 3Grade 3 ---- Maximum EfficiencyMaximum EfficiencyMaximum EfficiencyMaximum EfficiencyCoalescing, Oil Removal FilterCoalescing, Oil Removal FilterCoalescing, Oil Removal FilterCoalescing, Oil Removal Filter
Capable of providing air quality greater than
ISO 8573.1 class 1 solids and oil content
air quality
Captures 99.999+% of all oil aerosols
Reduces oil aerosol content to 0.0008 ppm
(0.001 mg/m3)
Best suited to critical applications
-
7/29/2019 Filter Final
12/23
HF Series Filters
Grade 1Grade 1Grade 1Grade 1 ----Oil Vapor Removal FilterOil Vapor Removal FilterOil Vapor Removal FilterOil Vapor Removal Filter
Capable of providing ISO 8573.1 class 1
solid and oil content air quality
Activated carbon adsorption filter
Contains 2x more carbon than supplied by
industrial activated carbon filters
Reduces oil aerosol content (as a vapor)
to 0.003 ppm
-
7/29/2019 Filter Final
13/23
HF Series Filters
Save EnergySave EnergySave EnergySave Energywith HF Series Filterswith HF Series Filterswith HF Series Filterswith HF Series Filters
Filter housing provides large flow paths
which minimizes pressure losses
The seven element grades allow for system
customization
-
7/29/2019 Filter Final
14/23
HF Series Filters
Elements Designed to ExtendElements Designed to ExtendElements Designed to ExtendElements Designed to ExtendLife and Reduce Pressure LossesLife and Reduce Pressure LossesLife and Reduce Pressure LossesLife and Reduce Pressure Losses
Large 45% open area stainless steel cores
provide even air flow through media at
minimal pressure losses
Filter media with over 96% void volume,lowers pressure losses while matrix blended
media increases capture efficiency
Thick filter bed extends useable life without
adding pressure losses
-
7/29/2019 Filter Final
15/23
HF Series Filters
Reliable Differential PressureReliable Differential PressureReliable Differential PressureReliable Differential PressureGauges & Monitor Save EnergyGauges & Monitor Save EnergyGauges & Monitor Save EnergyGauges & Monitor Save Energy
Three available methods of Differential
pressure indication
Electronic intelligence of the Filter Monitor
Face Gauge
Slide Indicator
Changing the filter elements at the proper
time saves energy and protects the
compressed air system
-
7/29/2019 Filter Final
16/23
HF Series Filters
Saving Energy bySaving Energy bySaving Energy bySaving Energy byReplacing Filter ElementsReplacing Filter ElementsReplacing Filter ElementsReplacing Filter Elements
Reduce energy losses by knowing when itscost effective to replace the filter elements
Differential pressure gauges determine theend of an elements life. Further
contaminant loading beyond this pointgreatly increases system pressure losses
Saves money and greatly minimize pressurelosses in systems by replacing the elementsat the end of their efficient life
Filter monitor calculates the point ofmaximum element efficiency. Loadingbeyond this point increases pressure to theend of the elements life.
-
7/29/2019 Filter Final
17/23
HF Series Filters
The Filter Monitor Evaluates:The Filter Monitor Evaluates:The Filter Monitor Evaluates:The Filter Monitor Evaluates:
Differential Pressure
Time based
Filter performance
-
7/29/2019 Filter Final
18/23
HF Series Filters
Differential Pressure and TimeDifferential Pressure and TimeDifferential Pressure and TimeDifferential Pressure and Time----Based IndicationsBased IndicationsBased IndicationsBased Indications
of Element Replacementof Element Replacementof Element Replacementof Element Replacement
Limits False Maximum Pressure Warnings
Provides a count down of days starting at 60
-
7/29/2019 Filter Final
19/23
HF Series Filters
Filter Performance IndicationFilter Performance IndicationFilter Performance IndicationFilter Performance Indicationof Element Replacementof Element Replacementof Element Replacementof Element Replacement
Calculates the moment of optimal
element replacement
Provides a 60 day notice before reaching
the replacement point
Monitor mathematically graphs the daily
average differential pressure
Monitor compares the calculated graph to a
known performance graph for each filter to
determine the optimum point of
element replacement
-
7/29/2019 Filter Final
20/23
HF Series Filters
Communicating withCommunicating withCommunicating withCommunicating withthe Filter Monitorthe Filter Monitorthe Filter Monitorthe Filter Monitor
All programming equipment is onboard
Uses (3) standard AA batteries for
simple maintenance
-
7/29/2019 Filter Final
21/23
HF Series Filters
Filter MonitorFilter MonitorFilter MonitorFilter MonitorCommunication with the UserCommunication with the UserCommunication with the UserCommunication with the User
Provides instantaneous differential
pressure values
Provides daily average differential
pressure values
Provides a 60 day warning of impending
element replacement
-
7/29/2019 Filter Final
22/23
HF Series Filters
Filter Monitor CommunicationsFilter Monitor CommunicationsFilter Monitor CommunicationsFilter Monitor Communications
Uses a RJ11 communications port to
interface with the Monitor Relay Box
-
7/29/2019 Filter Final
23/23
HF Series Filters
Remote Alarm CapabilitiesRemote Alarm CapabilitiesRemote Alarm CapabilitiesRemote Alarm Capabilities
RJ11 connection on the monitor can sendan alarm signal to the relay box as far as100 feet away
The relay box provides dry alarm contacts to
indicate the alarm mode of the Filter Monitorand an electronic demand drain
The relay box powers both the Filter Monitorand the electric demand drain