filter final

Upload: silk-road

Post on 04-Apr-2018

223 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 Filter Final

    1/23

    Flows from 20 to 21,250 scfm (34 to 36.119 m3

    /h)Maximum working conditions of 300 psig &

    150F (21 bar, 66C)

    HF Series Compressed Air FiltersHF Series Compressed Air FiltersHF Series Compressed Air FiltersHF Series Compressed Air Filters

  • 7/29/2019 Filter Final

    2/23

    HF Series Filters

    The ObjectiveThe ObjectiveThe ObjectiveThe Objective

    To meet and exceed the global demand for:

    Energy Savings

    Product Communication

    Quality & reliability

  • 7/29/2019 Filter Final

    3/23

    HF Series Filters

    Hankison Quality isHankison Quality isHankison Quality isHankison Quality isBuilt into Every HousingBuilt into Every HousingBuilt into Every HousingBuilt into Every Housing

    Epoxy coated interior and exterior

    Threaded discharge connection

    Bayonet head to bowl connectionup to 170 scfm (289 m3/h)

    Thermoset polyurethane liquid level indicator

    Every housing tested to a 5:1 factor of safety

  • 7/29/2019 Filter Final

    4/23

    HF Series Filters

    All stainless steel inner and outer cores

    Complete seam welded cores having aburst pressure of 65 psid (4.5 bar)

    Coated foam sleeves providing protectionagainst chemical attacks

    100% silicone free

    Hankison Quality is BuiltHankison Quality is BuiltHankison Quality is BuiltHankison Quality is Builtinto Every Filter Elementinto Every Filter Elementinto Every Filter Elementinto Every Filter Element

  • 7/29/2019 Filter Final

    5/23

    HF Series Filters

    Complete Filter OfferingComplete Filter OfferingComplete Filter OfferingComplete Filter Offering

    Seven grades of filtration allow systems tobe precisely customized

    Each element grade is tested to

    international standards

  • 7/29/2019 Filter Final

    6/23

    HF Series Filters

    Grade 11Grade 11Grade 11Grade 11 ---- Bulk Liquid SeparatorBulk Liquid SeparatorBulk Liquid SeparatorBulk Liquid Separator

    A labyrinth style flow path removes liquid

    water from the air stream by forcing abrupt

    directional changes

    Liquid water impinges on the walls of theinternal cores while the air stream flows

    easily through the labyrinth, providing

    minimal pressure losses

    Efficient to 5% of rated flow

    Removes up to 30,000 ppm liquid

    contamination at efficiencies greater

    than 90%

  • 7/29/2019 Filter Final

    7/23

    HF Series Filters

    Grade 9Grade 9Grade 9Grade 9 ---- Separator/FilterSeparator/FilterSeparator/FilterSeparator/Filter

    99% efficient at removing up to 25,000 ppm

    liquid water from an air stream

    In-depth coalescing bed captures solid and

    liquid contaminates 3 micron in sizeand larger

  • 7/29/2019 Filter Final

    8/23

    HF Series Filters

    Grade 7Grade 7Grade 7Grade 7 ---- Air Line FilterAir Line FilterAir Line FilterAir Line Filter

    Coarse coalescing filter capable of providing

    ISO 8573.1 class 2 solid and class 3 oil

    content air

    Captures and removes particles 1.0 micronand larger in size

    Remaining oil content as low as 1.0 mg/m3

    Extends life of fine coalescing Filters

  • 7/29/2019 Filter Final

    9/23

    HF Series Filters

    Grade 6Grade 6Grade 6Grade 6 ---- DesiccantDesiccantDesiccantDesiccant AfterfilterAfterfilterAfterfilterAfterfilter

    Designed to remove solid particles down to

    1.0 micron in size in a dry air flow

    Long life afterfilter for heatless

    desiccant dryers

    Outside/in flow, extends the usable life of

    the filter

  • 7/29/2019 Filter Final

    10/23

    HF Series Filters

    Grade 5Grade 5Grade 5Grade 5 ---- High EfficiencyHigh EfficiencyHigh EfficiencyHigh EfficiencyCoalescing Oil Removal FilterCoalescing Oil Removal FilterCoalescing Oil Removal FilterCoalescing Oil Removal Filter

    Capable of providing ISO 8573.1 class 1

    Solid and Class 1 oil content air quality

    Captures 99.99+% of all oil aerosols

    Reduces oil aerosol content to 0.008 ppm

    (0.01 mg/m3)

  • 7/29/2019 Filter Final

    11/23

    HF Series Filters

    Grade 3Grade 3Grade 3Grade 3 ---- Maximum EfficiencyMaximum EfficiencyMaximum EfficiencyMaximum EfficiencyCoalescing, Oil Removal FilterCoalescing, Oil Removal FilterCoalescing, Oil Removal FilterCoalescing, Oil Removal Filter

    Capable of providing air quality greater than

    ISO 8573.1 class 1 solids and oil content

    air quality

    Captures 99.999+% of all oil aerosols

    Reduces oil aerosol content to 0.0008 ppm

    (0.001 mg/m3)

    Best suited to critical applications

  • 7/29/2019 Filter Final

    12/23

    HF Series Filters

    Grade 1Grade 1Grade 1Grade 1 ----Oil Vapor Removal FilterOil Vapor Removal FilterOil Vapor Removal FilterOil Vapor Removal Filter

    Capable of providing ISO 8573.1 class 1

    solid and oil content air quality

    Activated carbon adsorption filter

    Contains 2x more carbon than supplied by

    industrial activated carbon filters

    Reduces oil aerosol content (as a vapor)

    to 0.003 ppm

  • 7/29/2019 Filter Final

    13/23

    HF Series Filters

    Save EnergySave EnergySave EnergySave Energywith HF Series Filterswith HF Series Filterswith HF Series Filterswith HF Series Filters

    Filter housing provides large flow paths

    which minimizes pressure losses

    The seven element grades allow for system

    customization

  • 7/29/2019 Filter Final

    14/23

    HF Series Filters

    Elements Designed to ExtendElements Designed to ExtendElements Designed to ExtendElements Designed to ExtendLife and Reduce Pressure LossesLife and Reduce Pressure LossesLife and Reduce Pressure LossesLife and Reduce Pressure Losses

    Large 45% open area stainless steel cores

    provide even air flow through media at

    minimal pressure losses

    Filter media with over 96% void volume,lowers pressure losses while matrix blended

    media increases capture efficiency

    Thick filter bed extends useable life without

    adding pressure losses

  • 7/29/2019 Filter Final

    15/23

    HF Series Filters

    Reliable Differential PressureReliable Differential PressureReliable Differential PressureReliable Differential PressureGauges & Monitor Save EnergyGauges & Monitor Save EnergyGauges & Monitor Save EnergyGauges & Monitor Save Energy

    Three available methods of Differential

    pressure indication

    Electronic intelligence of the Filter Monitor

    Face Gauge

    Slide Indicator

    Changing the filter elements at the proper

    time saves energy and protects the

    compressed air system

  • 7/29/2019 Filter Final

    16/23

    HF Series Filters

    Saving Energy bySaving Energy bySaving Energy bySaving Energy byReplacing Filter ElementsReplacing Filter ElementsReplacing Filter ElementsReplacing Filter Elements

    Reduce energy losses by knowing when itscost effective to replace the filter elements

    Differential pressure gauges determine theend of an elements life. Further

    contaminant loading beyond this pointgreatly increases system pressure losses

    Saves money and greatly minimize pressurelosses in systems by replacing the elementsat the end of their efficient life

    Filter monitor calculates the point ofmaximum element efficiency. Loadingbeyond this point increases pressure to theend of the elements life.

  • 7/29/2019 Filter Final

    17/23

    HF Series Filters

    The Filter Monitor Evaluates:The Filter Monitor Evaluates:The Filter Monitor Evaluates:The Filter Monitor Evaluates:

    Differential Pressure

    Time based

    Filter performance

  • 7/29/2019 Filter Final

    18/23

    HF Series Filters

    Differential Pressure and TimeDifferential Pressure and TimeDifferential Pressure and TimeDifferential Pressure and Time----Based IndicationsBased IndicationsBased IndicationsBased Indications

    of Element Replacementof Element Replacementof Element Replacementof Element Replacement

    Limits False Maximum Pressure Warnings

    Provides a count down of days starting at 60

  • 7/29/2019 Filter Final

    19/23

    HF Series Filters

    Filter Performance IndicationFilter Performance IndicationFilter Performance IndicationFilter Performance Indicationof Element Replacementof Element Replacementof Element Replacementof Element Replacement

    Calculates the moment of optimal

    element replacement

    Provides a 60 day notice before reaching

    the replacement point

    Monitor mathematically graphs the daily

    average differential pressure

    Monitor compares the calculated graph to a

    known performance graph for each filter to

    determine the optimum point of

    element replacement

  • 7/29/2019 Filter Final

    20/23

    HF Series Filters

    Communicating withCommunicating withCommunicating withCommunicating withthe Filter Monitorthe Filter Monitorthe Filter Monitorthe Filter Monitor

    All programming equipment is onboard

    Uses (3) standard AA batteries for

    simple maintenance

  • 7/29/2019 Filter Final

    21/23

    HF Series Filters

    Filter MonitorFilter MonitorFilter MonitorFilter MonitorCommunication with the UserCommunication with the UserCommunication with the UserCommunication with the User

    Provides instantaneous differential

    pressure values

    Provides daily average differential

    pressure values

    Provides a 60 day warning of impending

    element replacement

  • 7/29/2019 Filter Final

    22/23

    HF Series Filters

    Filter Monitor CommunicationsFilter Monitor CommunicationsFilter Monitor CommunicationsFilter Monitor Communications

    Uses a RJ11 communications port to

    interface with the Monitor Relay Box

  • 7/29/2019 Filter Final

    23/23

    HF Series Filters

    Remote Alarm CapabilitiesRemote Alarm CapabilitiesRemote Alarm CapabilitiesRemote Alarm Capabilities

    RJ11 connection on the monitor can sendan alarm signal to the relay box as far as100 feet away

    The relay box provides dry alarm contacts to

    indicate the alarm mode of the Filter Monitorand an electronic demand drain

    The relay box powers both the Filter Monitorand the electric demand drain