Page 1: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

Software rel. 2.3.x

FILLING CHECK VERSION WITH LEVEL SENSOR

Page 2: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

2

CONTENTS

● Legendofsymbols.....................................................................................................3INTRODUCTION ............................................................................................................4

Productdescription....................................................................................................4INTENDED USE .............................................................................................................4CONTENT OF THE PACKAGE .....................................................................................4PRECAUTIONS .............................................................................................................4RISKS AND PROTECTIONS BEFORE ASSEMBLY ....................................................5

Positioning..................................................................................................................5Powersupplyandsensorconnection........................................................................5

ASSEMBLY DIAGRAMS ...............................................................................................6CONTROLS IN THE MENU ...........................................................................................7

Firstswitchingon.......................................................................................................7Controlsinthemenu..................................................................................................8Workparameters........................................................................................................9

MENU STRUCTURE ....................................................................................................10PRELIMINARY SETUP FOR USE ............................................................................... 11

Alarms...................................................................................................................... 11Sensors....................................................................................................................13Flowmetercalibration(TOBEUSEDFORAUTOMATICTANKCALIBRATIONONLY)...........................................14Tank..........................................................................................................................15Tankcalibration........................................................................................................16Load/Savetank........................................................................................................21Language.................................................................................................................23Unitsofmeasurement..............................................................................................24Displaycontrast........................................................................................................25Alarmtones..............................................................................................................26Keytones..................................................................................................................26Fillingtolerance........................................................................................................27CANcommunication................................................................................................28Operatingmode.......................................................................................................29Setupmanagement..................................................................................................30Testmenu.................................................................................................................32

USE ..............................................................................................................................35MAINTENANCE / DIAGNOSTICS / REPAIRS ............................................................37

Troubleshooting........................................................................................................37END OF LIFE DISPOSAL ............................................................................................37TECHNICAL DATA ......................................................................................................38

Devicetechnicaldata...............................................................................................38Setupmenu..............................................................................................................39

GUARANTEE TERMS .................................................................................................40

Page 3: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

3

● Legendofsymbols

= Genericdanger

= Warning

This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.

Page 4: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

4

INTRODUCTION

Productdescription

VISIOisaverycompactandaccuratetop-notchmultifunctiondisplay,abletodisplayanykindofinformationconcerningagriculturaltreatments.Operatorcanselecttherequiredfunctionviasoftware.Itcandisplayseveraltypesofvalues,whichchangeaccordingtosetoperatingmodeandtypeofconnectedsensors.

INTENDED USE

This device is designed towork onagriculturalmachinery for spraying and cropsprayingapplications.ThemachineisdesignedandbuiltincompliancewithENISO14982standard(Electromagneticcompatibility-Forestryandfarmingmachines),harmonizedwith2014/30/UEDirective.

CONTENT OF THE PACKAGE

ThetablebelowindicatesthecomponentsthatyouwillfindintheVISIOpackage:

Legend:

1 VISIO2 Fixingkit3 Instructionmanual (onCD-ROM)4 Installationsheet

PRECAUTIONS

•Donotaimwaterjetsattheequipment.•Donotusesolventsorfueltocleanthecaseoutersurface.•Donotcleanequipmentwithdirectwaterjets.•Complywiththespecifiedpowervoltage(12VDC).•Incaseofvoltaicarcwelding,removeconnectorsfromVISIOanddisconnectthepowercables.•OnlyuseARAGgenuinesparepartsandaccessories.

P o w e r c a b l e ,s e n s o r s a n dconnection cablesto be connectedto VISIO must beorderedseparately.

Page 5: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

5

RISKS AND PROTECTIONS BEFORE ASSEMBLY

Allinstallationworksmustbedonewithbatterydisconnected,usingsuitabletoolsandanyindividualprotectionequipmentdeemednecessary.

Positioning

1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs.2) Secure VISIO to rail and push down until locked in place.3) Fasten wiring so that it does not interfere with any moving parts.

Powersupplyandsensorconnection

Sensorsandpowersupplymustbeinstalledandconnectedbyqualifiedpersonnel.VISIOmustbeexclusivelyconnectedtoARAGequipment.WHENARCWELDINGISREQUIRED,MAKESURETHATEQUIPMENTPOWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF NEEDED.ARAGisnotliablefordamagetothesystem,persons,animalsorpropertycausedbyVISIOwrongorunsuitableassembly.Failuretoobservetheaboveinstructionsautomaticallyvoidsthewarranty.

Wirecolor (powercable) Connectionof

red positive

black negative

green countingabort-groundconnection

yellow countingabort-connection+12VDC

power supplysensors

Page 6: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

6

ASSEMBLY DIAGRAMS

12

3

+12Vdc

GND

Counting abortGround

connection( )green wire

Counting abortConnection

+12VDC

( )yellow wire

Legend:1)Powercable2)Pumpstopkit3)Levelsensor4)Powercable-ConnectioncableforBravo300S/400S

STANDARD SYSTEM

SYSTEM WITH RCU

Page 7: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

7

CONTROLS IN THE MENU

Firstswitchingon

Atfirstswitchingon,VISIOwillrunaguidedprocedureallowingusertosetthedevice'sbasicsettings.

Press toscrollthroughitems,OKtosaveandmoveontonextsetting,orESCtogobacktoprevioussetting.

WARNING:Beforechangingoperatingmode,makesurethatallsensors/flowmetersareDISCONNECTEDfromthedevice.

Page 8: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

8

Controlsinthemenu

Inthefollowingpages,accordingtothesetoperatingmode,somemenuitemscouldslightlydifferfromtheshownones.

SWITCHING ONAPressfor1secondBPressthekeyafewtimestoviewthevariousvaluesinextendedmode(ondisplaycentralpart)Everytimethedeviceisswitchedon,itwillshortlyshowapagewiththenameofdeviceandsoftwareversion

SWITCHING OFFAPressfor2seconds

ACCESS TO SETUP MENUFromthemainpage,presskeysatthesametimefor2secondstoopentheSetupMenu

SELECTION AND ACCESS TO MENU ITEMS

APressafewtimestoscrollthroughitems(selecteditemisindicatedbyablackline)BPresstoopentheselectedmenuitem

Thethreedotsunderanitemindicatepresenceofanothersetupmenu

Page 9: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

9

EDITING A VALUEAPresstomovethroughdigitsBPressafewtimestoeditthehighlighteddigitCPresstoconfirm.ThedisplaygoesbacktopreviouspageDPresstoexitpagewithoutconfirmingmodification

Editedvaluemustfallwithintherangeshown

Workparameters

0

0% 50%25% 100%75%

Filling ¬

¬

Fromthemainpage,presskeyfortwosecondstoopenWorkParametersmenu,andsetvaluesforLevelcorrection.

Page 10: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

10

MENU STRUCTURE

Alarms

Tank reserveMax level

Sensors

Calib. flowmeterMan. calibration

Tank

CapacityTank zero value

Filling

¬

¬

0.0

0% 50%25% 100%75%

Calibration

Man. calibrationAuto calibration

Load/Save TankSave tank profileLoad tank profile

Options

Language

Units of measurem.

Flowrate

VolumelGalm

3

Display contrast

Alarm tones

Keytones

Fill tolerance

l/minGPMm

3/h

Operating mode

CAN communication

Setup management

Save setupLoad setup

Test

Firmware versionBattery voltageDisplayKeysSensorsCAN communication *

Fill control (L)

* Menu item active only if CAN communication is active.

Page 11: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

11

PRELIMINARY SETUP FOR USE

Alarms

Setthedesiredalarmdisplaythresholds.

Tank reserve alarm

Setthevalueoftheminimumfluidquantityleftinthetank.

1)Opentankreservealarmmenu(Setupmenu>Alarms>Tankreserve).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOKtoedittheselectedmenuitem

2)Todeactivatethealarm,press and

atthesametimeuntilthesetvalue

disappearsandthemessageOFFisdisplayedinstead.Carryoutthesameproceduretoenablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 12: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

12

Max tank level

Set themaximumtankcapacitypercentagevaluefor thedesiredalarmactivationthreshold.

1)Opentankmaxlevelmenu(Setupmenu>Alarms>Maxlevel).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

2) Toactivatethealarm,press and

atthesametimeuntilthemessage OFFgoesoffandthealarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 13: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

13

Sensors

1)OpenSensorsmenu(Setupmenu>Sensors).

Themenuitemsdisplayedbelowchangeaccordingtothesetoperationmode:whenmoreitemsareavailable,selectthedesiredoneandpressOKtoeditit.

Page 14: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

14

Flowmetercalibration (TOBEUSEDFORAUTOMATICTANKCALIBRATIONONLY)

Duetothedifferentsystemconfigurations(tubes,valves,etc.)ratereadingcouldnotbecorrect.Itisthereforerecommendedtoperformasprayingtest.Ifmeasuredvalueisdifferentfromactualvalue,changetherateconstantthroughanautomaticcalibrationprocedureormanuallycalculatetheconstant.

Manual calibration

Inordertomanuallysetrateconstant,calculateandsetsuitableconstantusingthefollowingformula:

1)Openmanualcalibrationmenu(Setupmenu>Calibration>Man.Calibration).UnderCalibrationmenu,selectMan.Calibration,toviewcurrentlysetconstantvaluebelowtheitem.PressOKtoeditthevalue.

Forflowmeterconstantvalue,refertothecorrespondingmanual.

2)Setflowmeterconstantvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

[quantity measured by equipment]

[actually sprayed quantity]x [constant indicated on flowmeter body]

Page 15: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

15

Tank

Fromthismenuitispossibletoviewandsetanumberoftankvalues.-Capacity:thedisplayshowsthemaximumtankcapacityvalue,aspreviouslycalculatedthroughcalibration.Thisvalueisread-only.

Tank zero value

Setlevelsensorzerovalue.Thelevelsensormustberesetinthefollowingcases:1)Iftherearediscrepanciesbetweenthequantityoffluidinthetankandthevaluemeasuredbythelevelsensor(e.g.,fluidpresencedetectedbutemptytank).2)EVERYTIMEacalibrationcurveisuploadedviaUSB.ThetankzerovaluemustALWAYSbesavedWITHANEMPTYTANK.

1)Opentankzerovaluemenu(Setupmenu>Tank>Tankzerovalue).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

2) PressOK:VISIOwillsavethelevelsensorzerovalue,whichwillbeshowninthebottompartofthedisplay(e.g.,3.964mAintheimageontheside).

Ifasensormalfunctionoccurs,themessageChecksensor!willbeshowninthetoppartofthedisplay.

Page 16: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

16

Tankcalibration

Thetankprofilecalibrationcanbecarriedoutinmanualorautomaticmode.Duringcalibration,VISIOwillsaveupto200calibrationpointstocreatethetankprofilecurve.If necessary, the tank profile can be saved and reimported intoVISIO orcompatibleARAGComputers(Bravo180S/300S/400S)atalatertime(e.g.,whenreusingthesametank).Beforestartingtheprocedurecarryoutthefollowingoperations:1)Fill the tankwith cleanwaterWITHOUTADDINGCHEMICALSUBSTANCES.Thetankmustbefull.2)Visuallycheckthereachedlevel.

Automatic tank calibration

Automaticcalibrationispossibleonlyifthesystemisequippedwithaflowmeter.

Legend:1)Powercable2)CableTO BE ORDERED SEPARATELY(ARAGcode4670610.110)3)Levelsensor4)Flowmeter5)Powercable-ConnectioncableforBravo300S/400S

STANDARD SYSTEM

SYSTEM WITH RCU

Page 17: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

17

1)Openautomaticcalibrationmenu(Setupmenu>Tank>Autocalibration).Press OK toedittheselectedmenuitem.

2)Setthetankmaximumcapacityvalue,i.e.,thetheoreticalquantityoffluidthatwaspreviouslyintroduced:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.3)Starttankdraining.Thedisplaywillstartshowingtheincreasingmeasuredfluidquantityvalue(centralareaofthedisplay),theinstantflowratevalue(bottomright),andtheprogressivenumberofmeasuredcalibrationpoints(bottomleft).

Ifasensormalfunctionoccurs,themessageCheck sensor! willbeshowninthetoppartofthedisplay.

Page 18: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

18

4)Oncethetankhasbeencompletelydrained,thevalueinthecentralareaofthedisplaywillstopchanging,andthemessageCompl. calib.?willappearinthedisplaytoppart.PressOKfor1secondtocompletecalibration.

5)Thedisplaywillgobacktothepreviousmenuandwillshowtheacquiredvalue.Incaseofmeasurementerrors,orifitisnecessarytostopthecalibration,pressESCfor2secondstoquitthecalibrationprocedurewithoutsaving.Inthiscase,thecurvewillbetheonepreviouslymeasured,orthedefaultcurve.

Page 19: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

19

Manual tank calibration

Toperformmanualcalibration,proceedasfollows:1) Calculate thesuitable calibration intervalwith respect to tankmaximumcapacity,bearinginmindthat:-itispossibletosaveupto200calibrationpoints;-ahighnumberofcalibrationpointsmakesformoreaccuratemeasurements.2)Adoptareliablemethodformeasuringthefluidquantitythatwaspreviouslycalculated.Example:

[2000 liters] = maximum tank capacity;[200 points] = set calibration points;[10 liters] * = measurement value in liters.*IMPORTANT:Setameasurementvaluethatisslightlyhigher(e.g.,11liters)thantheformula,inordertomakeupforanyerrorsintheevaluationoftankmaximumcapacity.

1) Openmanualcalibrationmenu(Setupmenu>Tank>Man.Calibration).Press OK toedittheselectedmenuitem.Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.

2)Starttankdraining.Once the measurement container is full, stop draining and, in the display central part, enter the volume of the drained fluid with respect to the previous calibration point:A) Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstoconfirm.

[2000 liters]

[200 points]= [10 liters]

Page 20: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

20

ThemessageStabilization willappearinthedisplaytoppartforafewseconds,thenitwillswitchbacktoRec. cal. point.

Thevalueofcalibrationpointswillincreasebyoneunit,andthevalueoftheprogressivelydrainedpartialvolumewillshowthequantityoffluidmeasureduptothatmoment.VISIOisreadyforanewmeasurement.

Itispossibletosavecalibrationpointsobtainedwithdifferentquantitiesofdrainedfluid.

4)Oncethetankhasbeenemptiedcompletely,press OK keyfor1secondtocompletethecalibrationprocessandsavetherelevantcurve.

5) Thedisplaywillgobacktothepreviousmenuandwillshowtheacquiredvalue.Incaseofmeasurementerrors,orifitisnecessarytostopthecalibration,pressESCkeyfor1secondtoquitthecalibrationprocedurewithoutsaving.Inthiscase,thecurvewillbetheonepreviouslymeasured,orthedefaultcurve.

Page 21: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

21

Load/Savetank

ThetankcalibrationcanbesavedorloadedontoaUSBpendrive,inordertorestoreitifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallcalibrationoperations.Onceinstallationiscompleted,checkVISIOoperationanditisrecommendedtosavethetankconfigurationonaUSBpendrive.ToloadorsavethecalibrationcurveitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.

1)Opentankconfigurationmenu(Setupmenu>Tank>Load/SaveTank).Press OK toedittheselectedmenuitem.

Load tank profile

AllowstoselectthetankconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.

WARNING:ByloadingtheTANK.TKLfilecontainedintheUSBpendriveontotheVISIO,thecurrenttankprofilewillbelost.

1) Selectcontrolthrough .

2)PressOKtoconfirmloading,orESCtoquitwithoutsaving.

TheTANK.TKLfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.

Page 22: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

22

Save tank profile

AllowssavingthetankconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.

1)Selectcontrolthroug .

2) PressOKtoconfirmsaving,orESCtoquitwithoutsaving.

IfaTANK.TKLfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.

Page 23: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

23

Language

Setthedesiredlanguage.

Options

Language

English

Units of measurem.Display contrast

Openlanguagesettingmenu(Setupmenu>Options>Language).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.

PressOK toeditlanguage.

2 1

2

Language

English

ČeskDeutsch

Español

1)Selectalanguagethrough .

2) PressOK tosave,orESC toquitwithoutsaving.

Page 24: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

24

Unitsofmeasurement

Setunitofmeasurementforthevaluesdetectedbythedevice.

Flowrate units of measurement

1)Openinstantrateunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Flowrate).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectflowrateunitofmeasurement.

1)Selectaunitthrough .

2)Press OK tosave,orESC toquitwithoutsaving.

Volume units of measurement

1)Openvolumeunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Volume).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectvolumeunitofmeasurement.

1)Selectaunitthrough .

2)Press OK tosave,orESC toquitwithoutsaving.

Page 25: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

25

Displaycontrast

Setdisplaycontrast.

Opendisplaycontrastmenu(Setupmenu>Options>Displaycontrast).

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setavaluethrough .Everytimeyoupressit,valuewillincreaseby5%up

to100%.Usekey todecreasevalue

by5%.2)PressOK tosave,orESC toquitwithoutsaving.

Page 26: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

26

Alarmtones

Enable/disablethealarmtones.

Openalarmtonesmenu(Setupmenu>Options>Alarmtones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Keytones

Enable/disablekeytones.

1)Openkeytonesmenu(Setupmenu>Options>Keytones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Page 27: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

27

Fillingtolerance

Setthepercentagevalueofpumpdeactivationadvanceduringfillingwithrespecttotankcapacity,inordertoreachtherealquantityoffluidintroducedintothetankmoreprecisely.

1)Openthefillingtolerancemenu(Setupmenu>Tank>Filltolerance).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK keytoedittheselectedmenuitem.

2)Setthefillingtolerancevaluewiththededicatedkeys:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 28: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

28

CANcommunication

FlowrateorlevelvaluescanalsobemeasuredbyconnectingVISIOtoacomputeroftheBravo300SRCUorBravo400Sseries(ASSEMBLYDIAGRAMS).InthiscasedataaresenttoVISIOdirectlybythecomputerRCUthroughtheCANbusconnection.Activatethefunctionasfollows:

1)OpenCANcommunicationmenu(Setupmenu>Options>CANcommunication).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOKtosave,orESCtoquitwithoutsaving.

IfCANcommunicationisactive,thecorrespondingitemwillalsobedisplayedunderthe"Test"Menu.

Page 29: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

29

Operatingmode

Setrequiredoperatingmode.

Openoperatingmodemenu(Setupmenu>Options>Operatingmode).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK tochangetheoperatingmode.

1)Selecttherequiredoperatingmode

through .

2)PressOK tosave,orESC toquitwithoutsaving.

WARNING:OnceOKispressed,thepageontwhesidewillbedisplayed.Beforechangingoperatingmode,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmchanges.ConnectthesensorsREQUIREDFORTHE SET OPERATING MODE.

Page 30: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

30

Setupmanagement

VISIOsettingscanbeloadedfromorsavedonaUSBpendriveinordertoreconfigureit ifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallmanualoperations.Onceinstallationiscompleted,andVISIOoperationhasbeenchecked,werecommendtosaveallsettingsontoaUSBpendrive.TobeabletousethefollowingfunctionsitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.

1)OpenSetupmanagementmenu(Setupmenu>Setupmanagement).

PressOK toedittheselectedmenuitem.

Load setupAllowstoselectaconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.WARNING:ByloadingtheSETUP.BIN filecontainedintheUSBpendriveontotheVISIO,allcurrentsettingswillbelost.

1)Selectthedesiredcontrolthrough key.2)PressOK toconfirmloading,orESC toquitwithoutsaving.

TheSETUP.BINfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.Ifsetupdownloadinvolveschangingoperatingmodeandusingdifferentsensorsthantheonesinuse,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmloading.Reconnectsensors.

Page 31: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

31

Save setupAllowssavingVISIOconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.

1)Selectthedesiredcontrolthrough

key.2)PressOK toconfirmsaving,orESC toquitwithoutsaving.

IfaSETUP.BINfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.

Page 32: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

32

Testmenu

ThismenuallowsusertoviewsomedataandcarryoutanoperationtestofVISIO:-Firmwareversion:thedisplayshowsthefirmwareversioninstalled.-Batteryvoltage:thedisplayshowsthepowervoltageofthedevice.

Display test

Displaytestchecksthedevicedisplaycorrectoperation.

1)Opendisplaytestmenu(Setupmenu>Test>Display).Press OK toperformthetest.

Allpixelsondisplayareturnedon.PressESCtogobacktopreviouspage.

Keys test

Keystestchecksthedevicekeyscorrectoperation.

Openkeystestmenu(Setupmenu>Test>Keys).

Press OK toperformthetest.

1)Pressanykeyandthecorrespondingdisplayareawillturnon.PressESC toquit:assoonasyouacknowledgetheswitch-ononofthecorrespondingareaonthedisplay,devicewillgobacktopreviouspage.

Page 33: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

33

Sensors test

Sensorstestcheckscorrectoperationofthesensorsconnectedtothedevice.

Opensensorstestmenu(Setupmenu>Test>Sensors).

Press OK toperformthetest.

Thedisplaywillshowthecurrentsensorreadingbelowtheselecteditem.1)Severalsensorscouldbedisplayed,dependingonthesetoperatingmode.Inthiscase,selectrequiredsensor

through .

2)PressESCtoquit.

Page 34: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

34

CANcommunicationtest

OpenCANcommunicationtest(Setupmenu>Test>CANcommunication).ThedisplayshowsCANcommunicationstatus.

TheCANdeviceshownisonlyanexample.

Page 35: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

35

USE

Themainpageshowsthedisplaydividedintothreehorizontalparts:

-toppart:theprogressbarshowsthetanklevelinpercentage.-centralpart:thevaluerepresentsthevolumeoffluidinsidethetank.-bottompart:theitemFillingreferstothekeyontheside,whichallowstoenterthefillingproceduremanagementmenu.

1)Press keyfortwosecondstoopen

themenuforsettingthefillingquantity.

2)Setfillingquantity:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

3)Keep keypressedfortwoseconds.

Fillingstarts.

Page 36: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

36

Thedisplayshowsthefollowingdata:-toppart:setfillingquantity;-centralpart:partialtotalizer;-bottompart:tanklevelinpercentage.

Pressthe keyseveraltimestoview

avalueinextendedmodeuntilrequiredvalueisondisplaycentralpart.

Displayedvaluescannotbedited.

TankfillingcanbeinterruptedatanytimebypressingESC.Pausemessagewillbeshownatthebottomofthedisplay.PressOKkeytoresumefilling;pressESCkeytofinallystopfillinganddisplaywillgobacktoinitialpage.

Whensetquantityisreached,fillingstopsautomatically.Completedmessagewillbeshownatthebottomofthedisplay.

Page 37: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

37

MAINTENANCE / DIAGNOSTICS / REPAIRS

•Cleanonlywithasoftwetcloth.•Donotuseaggressivedetergentsorproducts.•Donotcleanequipmentwithdirectwaterjets.

Troubleshooting

FAULT CAUSE REMEDY

VISIOisoffordoesnotswitchon

Nopowersupply Checkpowercableconnections

DeviceisOFF PresstheONkey

VISIOshowswrongdata

Wrongsetup Checkdisplayeddatasetup

Sensorfault ContactthenearestAssistanceCenterVISIOfault

Fillingpump(ifany)doesnotstart

PumpStopModulenotpowered

Checkpowersupplyconnection

END OF LIFE DISPOSAL

Disposeofthesystemincompliancewiththeestablishedlegislationinthecountryofuse.

Page 38: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

38

TECHNICAL DATA

Devicetechnicaldata

Description VISIO

Display GraphicLCD,128x64pixels,back-lighting

Powersupplyvoltage 9÷16Vdc

Protectionagainstshort-circuit •

Protectionagainstpolarityinversion •

Max.frequency 1.2KHz

Analoginputs 4÷20mA

Digitaloutput-Maxcurrent 100mA

Maximumpowerinput(withnosensorsconnected) 160mA

Operatingtemperature -20°C÷70°C-4°F÷+158°F

Storagetemperature -30°C÷80°C-22°F÷+176°F

Size 126x79x66mm

Weight 245g

Page 39: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

39

Setupmenu

Data Min. Max. Default UoM Notes

Calib. flowmeter Calibration 1 10000 OFF pls/l --

Alarms

Reservetank 0.1 1000 50 l/min. Alarmcanbedisabledbysettingvalueto"OFF"

Max.level 0.1 1000 OFF l/min. Alarmcanbedisabledbysettingvalueto"OFF"

Display Contrast 0 100 50 % --

Options

Language - - English -

Availablelanguages:Italiano,English,Español,Português,Français,Deutsch,Cesky,Polski,Русский,Magyar,ニホン .

Flowrateunitsofmeasurement - - l/min. l/min. Availableunitsofmeasurement:

l/min,GPM,m3/h

Volumeunitsofmeasurement - - l liters Availableunitsofmeasurement:

l,gal,m3

Fillingtolerance 0.1 50.0 00.0 % --

Page 40: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

40

GUARANTEE TERMS

1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateofsaletotheclientuser(dateofthegoodsdeliverynote).Thecomponentsoftheapparatus,thatintheunappealableopinionofARAGarefaultyduetoanoriginaldefectinthematerialorproductionprocess,willberepairedorreplacedfreeofchargeatthenearestAssistanceCenteroperatingatthemomenttherequestforinterventionismade.Thefollowingcostsareexcluded:

- disassemblyandreassemblyoftheapparatusfromtheoriginalsystem;- transportoftheapparatustotheAssistanceCenter.2. Thefollowingarenotcoveredbytheguarantee:- damagecausedbytransport(scratches,dentsandsimilar);- damageduetoincorrectinstallationortofaultsoriginatingfrominsufficientor

inadequatecharacteristicsoftheelectricalsystem,ortoalterationsresultingfromenvironmental,climaticorotherconditions;

- damageduetotheuseofunsuitablechemicalproducts,forspraying,watering,weedkillingoranyothercroptreatment,thatmaydamagetheapparatus;

- malfunctioningcausedbynegligence,mishandling,lackofknowhow,repairsormodificationscarriedoutbyunauthorizedpersonnel;

- incorrectinstallationandregulation;- damageormalfunctioncausedbythelackofordinarymaintenance,suchascleaning

offilters,nozzles,etc.;- anythingthatcanbeconsideredtobenormalwearandtear.3. Repairingtheapparatuswillbecarriedoutwithintimelimitscompatiblewiththe

organizationalneedsoftheAssistanceCenter.Noguaranteeconditionswillberecognizedforthoseunitsorcomponentsthathavenotbeenpreviouslywashedandcleanedtoremoveresidueoftheproductsused;

4. Repairscarriedoutunderguaranteeareguaranteedforoneyear(360days)fromthereplacementorrepairdate.

5. ARAGwillnotrecognizeanyfurtherexpressedorintendedguarantees,apartfromthoselistedhere.NorepresentativeorretailerisauthorizedtotakeonanyotherresponsibilityrelativetoARAGproducts.Theperiodoftheguaranteesrecognizedbylaw,includingthecommercialguaranteesandallowancesforspecialpurposesarelimited,inlengthoftime,tothevaliditiesgivenhere.InnocasewillARAGrecognizelossofprofits,eitherdirect,indirect,specialorsubsequenttoanydamage.

6. ThepartsreplacedunderguaranteeremainthepropertyofARAG.7. Allsafetyinformationpresentinthesalesdocumentsregardinglimitsinuse,

performanceandproductcharacteristicsmustbetransferredtotheenduserasaresponsibilityofthepurchaser.

8. AnycontroversymustbepresentedtotheReggioEmiliaLawCourt.

Page 41: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

CONFORMITY DECLARATION

The declaration of conformity is available at www.aragnet.com, in the relevant section.

Page 42: FILLING CHECK VERSION WITH LEVEL SENSOR · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and

42048 RUBIERA (Reggio Emilia) - ITALYVia Palladio, 5/ATel. +39 0522 622011Fax +39 0522 [email protected]

Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com

D20

287_

GB

-m04

03/2

017