figure 7 design and simulation of a mems thermal actuated micropump shiang-yu lin, huaning zhao,...

1
Figure 7 Design and Simulation of a MEMS Thermal Actuated Micropump Shiang-Yu Lin, Huaning Zhao, Advisor Prof. Xingguo Xiong Department of Biomedical Engineering, University of Bridgeport, Bridgeport, CT 06604 Abstract In this poster, the design and simulation of a MEMS thermal actuated micropump is reported. The micropump consists of a microfluic chamber on top of a thermal actuation chamber. Passive microvalves are embedded in the inlet and outlet of the pump to allow one-way flow of the microfluid. The thermal actuation chamber has sealed air inside it. A thermal resistor is embedded in the bottom surface of the actuation chamber. The top surface of actuation chamber is made by flexible thin silicon membrane. When a voltage is applied to the thermal resistor, the generated Joule heat raises the temperature of the sealed air in the actuation chamber. As a result, the air expands and presses the top membrane to bend up. In turn, the microfluid in the top chamber is pumped into the outlet. When the voltage is removed, the sealed air cools down due to thermal dissipation, and the silicon membrane becomes flat. Thus new fluid is sucked into the microfluidic chamber via inlet. The working principle of the micropump is analyzed in detail. Based on the theoretical analysis, a set of optimized design parameters of the micropump are suggested. ANSYS simulation is used to verify the function of the micropump. The proposed micropump can be used for lab-on-a-chip and micro drug delivery applications. Result and Discussion Two microvalves are used to regulate the microfluid flow inside the pump. As shown in Figure 2, in sucking mode, the elastic membrane restores to its flat position, the inlet valve is on and the outlet valve is off, microfluid is sucked into the container via inlet. In pumping mode, the elastic membrane bends down due to thermal expansion of air, the inlet valve is off and the outlet valve is on, the microfluid is pumped out via outlet. The voltage pulse to activate the micropump is set to be 15V. Based on analysis, a set of optimized design parameters of the micropump is achieved, as shown in Table 1. ANSYS FEM analysis is used to simulate the deformation of the PDMS elastic membrane under given pressure. The top view and side view of the contour plot of the elastic membrane bending shape are shown in Figure 5 and 6 separately. The temperature change inside air chamber in response to voltage pulse is shown in Fig. 7(a). As we can see, temperature first increase due to input voltage pulse. Once the voltage pulse is discontinued, the temperature drops quickly due to heat disscipation. Fig. 7(b) shows the deflection of elastic membrane with air pressure. As air pressure increases, the bending deflection of membrane increases accordingly. Introduction Micropumps are tiny pumps (in the size range of microns) fabricated with MEMS (Microelectromechanical Systems) technology. They are used to drive microfluid flow. As important bioMEMS devices, Micropumps have been used for many applications such as micro total analysis system (µTAS), Lab-on-a-chip (LoC), micro drug delivery system, etc. Various micropump designs have been reported. Depending on the actuation technique utilized, micropumps can be divided into piezoelectric micropump, electrostatic micropump, thermal actuated micropump, magnetic micropump, electrokinetic micropump, etc. Based on the structure, they can be divided into valved micropump and valveless micropump. Each different micropump has its own advantages and disadvantages, leading to its own specific applications. In this poster, a thermal micropump based on air electrothermal pneumatic actuation is proposed. The proposed micropump can be used for various bioMEMS applications. Figure 1.The structure of the micro pump Fabrication The proposed micropump can be fabricated with hybrid process. The components are fabricated separately and then assembled together into a micropump. The proposed fabrication flow is shown as Figure 4. 1. Fabricate top cover and heating resistor: Starting from Si wafer, deposit 0.4µm Al using evaporation. Then photolithography and etch Al into thermal resistors. 2. Fabricate Si chamber: Starting from silicon wafer, thermal oxidation for 0.6µm SiO 2 , photolithography and etching SiO 2 to open etching window. Use Si DRIE (Deep Reactive Ion Etching) to etch down into a chamber. Laser micromachining to drill holes in sidewall and bottom of chamber for inlet and outlet. 3. Assemble components into micropump: Insert elastic membrane into chamber, seal the edge, then bond top cover onto chamber. The micropump is complete. In this poster, the design and analysis of a thermal actuated MEMS micropump is proposed. The micropump utilizes air thermal expansion induced by resistor heating to pump microfluid flow. The working principle of the micropump is analyzed. ANSYS simulation is used to verify the deflection of elastic membrane in the micropump. In the future, we will perform ANSYS thermal-structure coupled-field analysis to simulate the micropump operation. Conclusions and Future Work Micropump Design and Working Principle The structure design of the MEMS thermal micropump is shown in Figure 1. As shown in Fig. 1, a cylinder pump container is connected to an inlet and outlet ports. There are embedded valves at the entrance of the inlet/outlet to regulate the flow direction of the microfluid. The microfluid is only allowed to enter the container via inlet, and come out of the container via outlet. The reverse microfluid flow is forbidden by the valves. In the middle of the pump body, there is an elastic membrane, which can bend under pressure difference from its top and bottom surfaces. The edge of the elastic membrane is seamlessly connected to the inner sidewall of the pump chamber. The top Si cover seals the chamber, and Al thermal resistor is pre- deposited on the bottom surface of the top cover. A certain amount of air is sealed inside the air chamber. When a voltage is applied to the thermal resistor, conducting current results in Joule heat and heat up the temperature of the air chamber. As a result, the air expands and pushes the elastic membrane to bend down. The volume of chamber container is reduced and the microfluid inside the chamber is pumped out via outlet. However, if the driving voltage is disconnected, the air temperature inside the air chamber will decrease due to thermal dissipation. Thus the volume of air shrinks, and the elastic membrane returns to its flat shape. As a result, the volume of container expands, and the microfluid is sucked into the pump. By repeating this process (applying a pulse voltage), the microfluid can be continuously pumped in from the inlet and pumped out from the outlet. This is the working principle of the micropump. Figure 4. Fabrication process sequence of micropump Figure 3. Bending of elastic membrane Assume voltage pulse V is applied to heating resistor R for a time period of T, the generated Joule heat by the heating resistor is: Device Analysis Figure 5, 6. Top/side view of elastic membrane bending shape (ANSYS simulation) ) /( air air c m E T Parameter Dimension chamber diameter D 2400μm air chamber height h 1 500μm container height h 2 800μm PDMS membrane thickness 40μm Figure 2. Working modes of thermal MEMS micropump (a). Sucking mode: inlet valve on, outlet valve off (b). Pumping mode: inlet valve off, outlet valve on T R V E ) / ( 2 where R is the resistance of heating resistor. Assume there are N folds of heating resistor, and the width, length and thickness of each fold is w, l and t respectively, ) /( wt l N R Assume energy transfer efficiency from heating resistors to the air inside the chamber as η (0<η<1 due to heat dissipation). The resulted temperature increase of the air due to thermal heating is: where m air is the mass of air, and c air is the heat capacity of air. The sealed air inside the chamber follows combined gas law: 2 2 2 1 1 1 / / T V P T V P where P 1 is the initial air pressure before heating (P 1 =1atm), V 1 is the initial air volume (V 1 =S×h 1 , where S and h 1 are the cross section area and height of air chamber), T 1 is room temperature (T 1 =27ºC=300K), P 2 is the final air pressure inside the chamber, V 2 is the final air volume after thermal expansion, and T 2 =T 1 +ΔT is the final temperature of air. From above equations, we can find out the final air pressure inside the chamber, and based on the properties of elastic membrane, we can further find out the bending displacement of the membrane. This allows us to calculate the expected volume change of the container, and in turn derive the predicted pumping flow rate. Based on above analysis, we can derive a set of optimized design parameters of the micropump, and calculate its expected performance. ANSYS simulation should be used to simulate the behavior of the micropump, and ANSYS simulation results will be compared with theoretical calculation results to verify the design model. Table 1. Design parameters of the micropump

Upload: cameron-leonard

Post on 17-Dec-2015

216 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Figure 7 Design and Simulation of a MEMS Thermal Actuated Micropump Shiang-Yu Lin, Huaning Zhao, Advisor Prof. Xingguo Xiong Department of Biomedical Engineering,

Figure 7

Design and Simulation of a MEMS Thermal Actuated Micropump Shiang-Yu Lin, Huaning Zhao, Advisor Prof. Xingguo Xiong

Department of Biomedical Engineering, University of Bridgeport, Bridgeport, CT 06604

AbstractIn this poster, the design and simulation of a MEMS thermal actuated micropump is reported. The micropump consists of a microfluic chamber on top of a thermal actuation chamber. Passive microvalves are embedded in the inlet and outlet of the pump to allow one-way flow of the microfluid. The thermal actuation chamber has sealed air inside it. A thermal resistor is embedded in the bottom surface of the actuation chamber. The top surface of actuation chamber is made by flexible thin silicon membrane. When a voltage is applied to the thermal resistor, the generated Joule heat raises the temperature of the sealed air in the actuation chamber. As a result, the air expands and presses the top membrane to bend up. In turn, the microfluid in the top chamber is pumped into the outlet. When the voltage is removed, the sealed air cools down due to thermal dissipation, and the silicon membrane becomes flat. Thus new fluid is sucked into the microfluidic chamber via inlet. The working principle of the micropump is analyzed in detail. Based on the theoretical analysis, a set of optimized design parameters of the micropump are suggested. ANSYS simulation is used to verify the function of the micropump. The proposed micropump can be used for lab-on-a-chip and micro drug delivery applications.

Result and Discussion

Two microvalves are used to regulate the microfluid flow inside the pump. As shown in Figure 2, in sucking mode, the elastic membrane restores to its flat position, the inlet valve is on and the outlet valve is off, microfluid is sucked into the container via inlet. In pumping mode, the elastic membrane bends down due to thermal expansion of air, the inlet valve is off and the outlet valve is on, the microfluid is pumped out via outlet. The voltage pulse to activate the micropump is set to be 15V.

Based on analysis, a set of optimized design parameters of the micropump is achieved, as shown in Table 1. ANSYS FEM analysis is used to simulate the deformation of the PDMS elastic membrane under given pressure. The top view and side view of the contour plot of the elastic membrane bending shape are shown in Figure 5 and 6 separately. The temperature change inside air chamber in response to voltage pulse is shown in Fig. 7(a). As we can see, temperature first increase due to input voltage pulse. Once the voltage pulse is discontinued, the temperature drops quickly due to heat disscipation. Fig. 7(b) shows the deflection of elastic membrane with air pressure. As air pressure increases, the bending deflection of membrane increases accordingly.

IntroductionMicropumps are tiny pumps (in the size range of microns) fabricated with MEMS (Microelectromechanical Systems) technology. They are used to drive microfluid flow. As important bioMEMS devices, Micropumps have been used for many applications such as micro total analysis system (µTAS), Lab-on-a-chip (LoC), micro drug delivery system, etc. Various micropump designs have been reported. Depending on the actuation technique utilized, micropumps can be divided into piezoelectric micropump, electrostatic micropump, thermal actuated micropump, magnetic micropump, electrokinetic micropump, etc. Based on the structure, they can be divided into valved micropump and valveless micropump. Each different micropump has its own advantages and disadvantages, leading to its own specific applications. In this poster, a thermal micropump based on air electrothermal pneumatic actuation is proposed. The proposed micropump can be used for various bioMEMS applications.

Figure 1.The structure of the micro pump

FabricationThe proposed micropump can be fabricated with hybrid process. The components are fabricated separately and then assembled together into a micropump. The proposed fabrication flow is shown as Figure 4.1. Fabricate top cover and heating resistor: Starting from Si wafer, deposit 0.4µm Al using evaporation. Then photolithography and etch Al into thermal resistors.2. Fabricate Si chamber: Starting from silicon wafer, thermal oxidation for 0.6µm SiO2, photolithography and etching SiO2 to open etching window. Use Si DRIE (Deep Reactive Ion Etching) to etch down into a chamber. Laser micromachining to drill holes in sidewall and bottom of chamber for inlet and outlet. 3. Assemble components into micropump: Insert elastic membrane into chamber, seal the edge, then bond top cover onto chamber. The micropump is complete.

In this poster, the design and analysis of a thermal actuated MEMS micropump is proposed. The micropump utilizes air thermal expansion induced by resistor heating to pump microfluid flow. The working principle of the micropump is analyzed. ANSYS simulation is used to verify the deflection of elastic membrane in the micropump. In the future, we will perform ANSYS thermal-structure coupled-field analysis to simulate the micropump operation.

Conclusions and Future Work

Micropump Design and Working PrincipleThe structure design of the MEMS thermal micropump is shown in Figure 1. As shown in Fig. 1, a cylinder pump container is connected to an inlet and outlet ports. There are embedded valves at the entrance of the inlet/outlet to regulate the flow direction of the microfluid. The microfluid is only allowed to enter the container via inlet, and come out of the container via outlet. The reverse microfluid flow is forbidden by the valves. In the middle of the pump body, there is an elastic membrane, which can bend under pressure difference from its top and bottom surfaces. The edge of the elastic membrane is seamlessly connected to the inner sidewall of the pump chamber. The top Si cover seals the chamber, and Al thermal resistor is pre-deposited on the bottom surface of the top cover. A certain amount of air is sealed inside the air chamber. When a voltage is applied to the thermal resistor, conducting current results in Joule heat and heat up the temperature of the air chamber. As a result, the air expands and pushes the elastic membrane to bend down. The volume of chamber container is reduced and the microfluid inside the chamber is pumped out via outlet. However, if the driving voltage is disconnected, the air temperature inside the air chamber will decrease due to thermal dissipation. Thus the volume of air shrinks, and the elastic membrane returns to its flat shape. As a result, the volume of container expands, and the microfluid is sucked into the pump. By repeating this process (applying a pulse voltage), the microfluid can be continuously pumped in from the inlet and pumped out from the outlet. This is the working principle of the micropump.

Figure 4. Fabrication process sequence of micropump

Figure 3. Bending of elastic membrane

Assume voltage pulse V is applied to heating resistor R for a time period of T, the generated Joule heat by the heating resistor is:

Device Analysis

Figure 5, 6. Top/side view of elastic membrane bending shape (ANSYS simulation)

)/( airair cmET

Parameter Dimension

chamber diameter D 2400μm

air chamber height h1 500μm

container height h2 800μm

PDMS membrane thickness 40μm

Figure 2. Working modes of thermal MEMS micropump

(a). Sucking mode: inlet valve on, outlet valve off (b). Pumping mode: inlet valve off, outlet valve on

TRVE )/( 2

where R is the resistance of heating resistor. Assume there are N folds of heating resistor, and the width, length and thickness of each fold is w, l and t respectively,

)/(wtlNR

Assume energy transfer efficiency from heating resistors to the air inside the chamber as η (0<η<1 due to heat dissipation). The resulted temperature increase of the air due to thermal heating is:

where mair is the mass of air, and cair is the heat capacity of air. The sealed air inside the chamber follows combined gas law:

222111 // TVPTVP where P1 is the initial air pressure before heating (P1=1atm), V1 is the initial air volume (V1=S×h1, where S and h1 are the cross section area and height of air chamber), T1 is room temperature (T1=27ºC=300K), P2 is the final air pressure inside the chamber, V2 is the final air volume after thermal expansion, and T2=T1+ΔT is the final temperature of air. From above equations, we can find out the final air pressure inside the chamber, and based on the properties of elastic membrane, we can further find out the bending displacement of the membrane. This allows us to calculate the expected volume change of the container, and in turn derive the predicted pumping flow rate. Based on above analysis, we can derive a set of optimized design parameters of the micropump, and calculate its expected performance. ANSYS simulation should be used to simulate the behavior of the micropump, and ANSYS simulation results will be compared with theoretical calculation results to verify the design model.

Table 1. Design parameters of the micropump