field report - pavilion construction · project name: 12. th. avenue apartments project number:...

15
Page 1 of 2 Architect’s Supplemental Instructions ASI NUMBER: 022 PROJECT NAME: 12 th Avenue Apartments PROJECT NUMBER: 1343 4119 & 4123 12 th Avenue Seattle, WA DATE OF ISSUANCE: April 1, 2014 OWNER: Matt Booma CA Student Living Owner 161 N. Clark, Suite 4900 Architect Chicago, Illinois 60601 Consultant Contractor TO CONTRACTOR: Robert Beeler Field Pavilion Construction 6720 SW Macadam Ave., Suite #310 Portland, OR 97219 FROM NK Architects THE ARCHITECTS: 310 First Avenue S, Suite 4S Seattle, WA 98104 The Work shall be carried out in accordance with the following supplemental instructions in accordance with the Contract Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these instructions indicates your acknowledgement that there will be no change in the Contract Sum of Contract time. DESCRIPTION: 1) Provide and install IP Based CCTV security system cameras at interior locations and the following locations shown in the attached plans marked up by owner to show camera locations. Coordinate with security consultant. Coordinate installation of the system with other low-voltage electrical and signal systems. 2) Provide Schlage FE210F.PDF electronic interconnected locks at all unit entries, [finish and lever option TBD]; provide appropriate Schlage Fobs at the rate of 1 per bedroom, and a percentage extra per owner. Provide software and instruments necessary to audit and electronically rekey locks. Appropriate Keyfobs shall be compatible with the Schlage FE210F.PDF and hardwired card reader / electronic strikes at the following door openings: 004 (Bicycle Parking), 005 (Basement Entry), 101 (Call Box w/ Cardreader), 800 (elevator penthouse lobby to roof deck). 3) Provide Schlage Fob compatible Cardreaders at the following door locations 004 (Bicycle Parking), 005 (Basement Entry), 101 (Call Box w/ Cardreader), 800 (elevator penthouse lobby to roof deck). Coordinate call box at location 101 with cardreader system. Coordinate with low voltage electrical system installation. 4) Provide exterior exposure rated keyed, locking mechanical entry locks at the (3) exterior gate locations: Gate / Door 108 (stairway B), double leaf gate for vehicle access to refuse area and transformer well on the northwest, and gate at the southeast corner of the property. Provide locksets and hardware that are rated for exterior environmental exposure. At the double gate provide bolt hardware and associated holes in the paving to allow the gates to be bolted open and closed in a secure manner.

Upload: others

Post on 02-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

Page 1 of 2

Architect’s Supplemental Instructions ASI NUMBER: 022

PROJECT NAME: 12th Avenue Apartments PROJECT NUMBER: 1343 4119 & 4123 12th Avenue Seattle, WA DATE OF ISSUANCE: April 1, 2014 OWNER: Matt Booma CA Student Living Owner 161 N. Clark, Suite 4900 Architect Chicago, Illinois 60601 Consultant Contractor TO CONTRACTOR: Robert Beeler Field Pavilion Construction 6720 SW Macadam Ave., Suite #310 Portland, OR 97219 FROM NK Architects THE ARCHITECTS: 310 First Avenue S, Suite 4S Seattle, WA 98104 The Work shall be carried out in accordance with the following supplemental instructions in accordance with the Contract Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these instructions indicates your acknowledgement that there will be no change in the Contract Sum of Contract time.

DESCRIPTION:

1) Provide and install IP Based CCTV security system cameras at interior locations and the following locations shown in the attached plans marked up by owner to show camera locations. Coordinate with security consultant. Coordinate installation of the system with other low-voltage electrical and signal systems.

2) Provide Schlage FE210F.PDF electronic interconnected locks at all unit entries, [finish and lever option TBD]; provide appropriate Schlage Fobs at the rate of 1 per bedroom, and a percentage extra per owner. Provide software and instruments necessary to audit and electronically rekey locks. Appropriate Keyfobs shall be compatible with the Schlage FE210F.PDF and hardwired card reader / electronic strikes at the following door openings: 004 (Bicycle Parking), 005 (Basement Entry), 101 (Call Box w/ Cardreader), 800 (elevator penthouse lobby to roof deck).

3) Provide Schlage Fob compatible Cardreaders at the following door locations 004 (Bicycle Parking), 005 (Basement Entry), 101 (Call Box w/ Cardreader), 800 (elevator penthouse lobby to roof deck). Coordinate call box at location 101 with cardreader system. Coordinate with low voltage electrical system installation.

4) Provide exterior exposure rated keyed, locking mechanical entry locks at the (3) exterior gate locations: Gate / Door 108 (stairway B), double leaf gate for vehicle access to refuse area and transformer well on the northwest, and gate at the southeast corner of the property. Provide locksets and hardware that are rated for exterior environmental exposure. At the double gate provide bolt hardware and associated holes in the paving to allow the gates to be bolted open and closed in a secure manner.

Page 2: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

Page 2 of 2

At gate / door 108 and gate at southeast corner of the property provide exterior rated and code approved gate / door closers; coordinate with gate / door design.

5) Provide Door position switch / contactor at the following gate / door locations: 102, 108 and the southeast gate. Provide “NOT AN EXIT SIGN” at Door 102. Coordinate with low voltage electrical system installation.

6) At Gate / Door 108 provide an audible alarm when the door opens. Coordinate with low voltage electrical system installation.

Page 3: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

UP

UP

UP

A3.01

A3.0

A3.1

A3.1

1

2

2

1A4.0

1A4.0

2A4.0

2A4.0

B16TRANSFORMER VAULT

B13STUDIO

UNIT C.1 ON A5.3

B12STUDIO

UNIT B.1 ON A5.2

B11STUDIO

UNIT B.1 ON A5.2

B10STUDIO

UNIT B.1 ON A5.2 B09STUDIO

UNIT B.4 ON A5.2

B08STUDIO

UNIT A.3 ON A5.1

B07STUDIO

UNIT A.2 ON A5.1

B06

BICYCLEPARKING

B17

TENANTSTORAGE

B00STAIR A

B02ELEV

B01STAIR B

10' -

0"

10' -

0"

2' -

11"

B03CORR.

T.O. SLABELEV:

PATIO PATIO PATIO PATIO PATIO

012

010

004

001

009

D

D

005

C1

C1C1

C2C2C2

C1C1

C1

C1

C1 B6

B6

C2

C2

A7.12

5

5

AA

BB

C C

D D

E

E

F F

6

62

2

A7.23

1

1

3

3

4

4

86' - 2"

2A-FE

CANOPY ABOVE

74' -

10"

57' - 2" 5' - 3" 8' - 3" 15' - 6" 5' - 0"

5' -

11"

12' -

11"

13' -

1"

36' -

3"

3' -

0"

3A8.0

1A8.0

2A8.0

A7.01

EXIT

EXIT

EXIT

EXIT

CCCC

2' - 5"

2' -

2"

2' -

2"

B04

SPRINKLERROOM

WINDOWWELL

5'-0

" CLR

.

5'-0" CLR.

B18METER

24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"

18' - 1" 6' - 9" 14' - 1" 9' - 8" 8' - 9" 5' - 1"

3' -

11"

19' -

1"

7' -

2"12

' - 1

0"6'

- 0"

17' -

2"

8' -

8"

1' - 5 3/4"

13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"

1' -

0"

2' -

11"

B05TELECOM

106' - 1"

16' -

11"

15' -

1"

23' -

4"

6' -

10"

3' -

6"

T.O. SLABELEV:

109' - 1"

109' - 1"T.O. SLABELEV:

109' - 1"T.O. PATIOELEV:

002

006

R

A5.41

C2C2

C3

C1

C1

C2

C3

C2

C1

C2

B4

B4 B4 B4

C2

B4

B1B1

B6

C2

C2C2

B4

C2

B3

008

B3003

011

15' -

7"

23' - 6"

A9.79

1' - 6"

B6

SHAFTABOVE

C1

C

115' - 6"T.O. WALLELEV.

C2C2

B6

12' -

0"

A9.715

A9.113

B14

TRANSFORMERVESTIBULE

115' - 6"T.O. WALLELEV.

4A5.4

5A5.4

4A8.0

B6

DN

A 3.1

1

A 3.0

A 3.0

A 3.1 2

AFFORDABLEHOUSING UNIT

A9.21

4' - 10"

12" MIN

007

7' -

5"

B15

TRANSFORMERACCESS WELL

SLOPE SLAB 1/8" PER FT. MIN.

SLOPE SLAB1/8" PER FT. MIN.

A9.112

PROVIDE CONCRETEWALLS W/ LID TO HOUSEMECH. INTAKE + LOUVERPER SHEET M2.1

1/4":12"

1/4":12"

1/4"

:12"

1/4"

:12"

1/4"

:12"

1/4"

:12"

1/4"

:12"

WALL TYPE + SOFFIT KEY

2-HR FIRE-RATED WALL

CONCRETE WALL

CMU WALL

STEEL OR WOOD STUD WALL

SOFFIT/LOWERED CEILING

SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY

INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL

GENERAL FLOOR PLAN NOTES:

• NICHOLSON KOVALCHICK ARCHITECTS

310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154

www.nkarch.com

2013 NICHOLSON KOVALCHICK ARCHITECTS PSC

FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:

REVISIONS

ISSUANCE

#

A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13

A2.0

115205.22.2013

SL, AMMG1152_TRIAD 12TH

FLOOR PLAN -BASEMENT

TRIA

D 1

2TH

AVE

NU

E41

19 &

412

3 12

TH A

VEN

UE

NE

SEAT

TLE,

WA

9810

5

TRIA

D C

APIT

AL

SCALE: 1/8" = 1'-0"LEVEL B11

NORTH

UNIT AREAS - LEVEL B1UNIT NET SF GROSS SF

B07 271 SF 313B08 246 SF 310B09 252 SF 300B10 258 SF 295B11 258 SF 295B12 258 SF 295B13 269 SF 339 1 MUP CORRECTION 09.10.12

3 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.136 ADDENDUM 1 08.27.13

6

6

66666

6 66 6 6

Eric
Oval
Eric
Oval
Eric
Oval
Eric
Oval
Eric
Line
Eric
Line
Eric
Line
Eric
Line
Eric
Text Box
FOB
Eric
Text Box
FOB
Eric
Oval
Eric
Line
Eric
Line
Page 4: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

UP

UP

A3.01

A3.0

A3.1

A3.1

1

2

2

1A4.0

1A4.0

2A4.0

2A4.0

113STUDIO

UNIT C.1 ON A5.3

112STUDIO

UNIT B.1 ON A5.2

111STUDIO

UNIT B.1 ON A5.2

110STUDIO

UNIT B.1 ON A5.2 109STUDIO

UNIT B.4 ON A5.2

108STUDIO

UNIT A.3 ON A5.1

107LOBBY

UNIT A.2 ON A5.1

115STUDIO

UNIT B.3 ON A5.2

100STAIR A

102ELEV

106STUDIO

UNIT A.2 ON A5.1

116STUDIO

UNIT B.2 ON A5.2 117STUDIO

UNIT B.5 ON A5.369

' - 6

"

118LOBBY

114

REFUSE/RECYCLING

AREA

24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"

101STAIR B

103CORR.

BLD

G.

EXIT

FIN. GRADEELEV: 116'-8 1/2"

118' - 3"T.O. SLABELEV.

115' - 6"T.O. WALLELEV.

6' -

10"

23' -

4"

16' -

1"

10' -

4"

19' -

9"

PATIO PATIO PATIO PATIO PATIO

10' -

0"

10' -

0"

WIN

DO

W W

ELL

BEL

OW

12TH

AVE

NU

E N

E

ALLE

Y

T.O. STAIRELEV. 114' - 9"

DECORATIVEPROJECTINGBUILDING FINSABOVE

DECORATIVEPROJECTING

BUILDING FINSABOVE

106

107

FF F

A

H

H

H

120BATH

119

CONCIERGEOFFICE

104

B6

26' -

2"

12' -

10"

13' -

4"

12' -

11"

A7.13

86' - 2"

5

5

AA

BB

C C

D D

E

E

F F

6

62

2

A7.24

100

1

1

3

3

4

4

2A-FE

BLDG.ENTRY

CANOPYBELOW

METALGATE

DECORATIVE METALSECURITY GATE

DECORATIVEMETAL GATE

7' SCREEN FENCE @PROPERTY LINE

7' SCREEN FENCE @PROPERTY LINE

7' SCREENFENCE @PROPERTYLINE

A5.01

3A8.0

1A8.0

2A8.0

C4

C1C1

EXIT

EXIT

EXIT

EXIT

EXIT

A C C

E.1

MAILBOXES

1' - 7"

7' -

6"

7' -

3"3'

- 5"

10' -

2"

17' -

2"

6' -

0"12

' - 1

0"7'

- 2"

19' -

1"

5'-0

" CLR

.

5'-0" CLR.

57' - 2" 5' - 3" 23' - 9"

13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"

18' - 1" 7' - 11" 10' - 10" 11' - 9" 8' - 1" 5' - 9" 15' - 9" 8' - 0"

118' - 3"T.O. F.F.ELEV:

VESTIBULE

103

105

5'-0" CLR.

Q

P

L

M

OC2C2

C1

B4 B4 B4 B4

C2C2C2

E4

B4

B4

B4

B3

B6

C2

C2

C1C1

C2 C2

C2

B4 B4 C2 C2C2

E4

E4

AWNINGABOVE(SBO)

A9.79

UP

UP

EXITDISCHARGE

8 CUBIC YARDDUMPSTER

8 CUBIC YARDDUMPSTER

TRANSFORMERACCESS HATCH

115' - 6"T.O. WALLELEV:

116' - 9"T.O. SLAB @ LANDINGELEV:

B6

A9.715

39' -

9"

25' -

6"

115' - 6"T.O. WALLELEV.

5' - 0" 5' - 0" 5' - 0" 5' - 0"

4A5.4

5A5.4

F

7' SCREEN FENCE@ PROPERTY LINE

C1

4A8.0

BENCH PERLANDSCAPE DRAWINGS

BENCH

A 3.1

1

A 3.0

A 3.1 2

AFFORDABLEHOUSING UNIT

A9.21

42" GUARDRAIL

42" GUARDRAIL

EXIT N

101102

5

A9.0

A9.22

A9.411

4

A9.0

A9.112

A9.113

A6.01

MECH.WELL

MECH.WINDOWWELL

2' - 8"

2' -

8" 12"

11' - 1" 2' - 8" 10' - 2"

2' -

8"

PROVIDE CONCRETEWALLS W/ LID TO HOUSEMECH. INTAKE + LOUVER

PER SHEET M2.1

1 HR. RATEDCEILING BELOW

PLUMBING PIPES

U

MAILBOXES

6 6 6

F

108

1/8"

:12"

2' - 10"

2' -

10"

30" W x 24" HLOUVER

B

AFFORDABLE HOUSING REQ'D: 1,080 GSFAFFORDABLE HOUSING TABLE

LEVEL B1 UNIT B08 246 NSF 310 GSF

LEVEL 1 UNIT 117 255 NSF 314 GSF

LEVEL 2 UNIT 217 256 NSF 318 GSF

LEVEL 3 UNIT 317 272 NSF 320 GSF

AFFORDABLE HOUSING PROVIDED: 1,029 NSF; 1,262 GSF

WALL TYPE + SOFFIT KEY

2-HR FIRE-RATED WALL

CONCRETE WALL

CMU WALL

STEEL OR WOOD STUD WALL

SOFFIT/LOWERED CEILING

SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY

INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL

GENERAL FLOOR PLAN NOTES:

NICHOLSON KOVALCHICK ARCHITECTS

310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154

www.nkarch.com

2013 NICHOLSON KOVALCHICK ARCHITECTS PSC

FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:

REVISIONS

ISSUANCE

#

A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13

A2.1

115205.22.2013

SL, AMMG1152_TRIAD 12TH

FLOOR PLAN -LEVEL 1

TRIA

D 1

2TH

AVE

NU

E41

19 &

412

3 12

TH A

VEN

UE

NE

SEAT

TLE,

WA

9810

5

TRIA

D C

APIT

AL

NORTH

SCALE: 1/8" = 1'-0"LEVEL 1 (TYPE 1A)1

UNIT AREAS - LEVEL 1UNIT NET SF GROSS SF

106 277 SF 325108 259 SF 317109 249 SF 300110 255 SF 294111 255 SF 294112 255 SF 294113 266 SF 339115 247 SF 305116 257 SF 294117 253 SF 314

1 MUP CORRECTION 09.10.122 MUP CORRECTION 2 01.21.133 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.136 ADDENDUM 1 08.27.13

6

6

6

6

6

Eric
Oval
Eric
Oval
Eric
Oval
Eric
Oval
Eric
Oval
Eric
Line
Eric
Line
Eric
Line
Eric
Line
Eric
Oval
Eric
Line
Eric
Line
Eric
Oval
Eric
Line
Eric
Callout
Door position switch/contactor, Mechanical Lock
Eric
Rectangle
Eric
Callout
Door position switch/contactor, Audible Alarm, Mechanical Lock
Eric
Rectangle
Eric
Oval
Eric
Line
Eric
Rectangle
Eric
Callout
Call Box with Fob
Eric
Rectangle
Eric
Callout
Door position switch/contactor?, Mechanical Lock
Eric
Callout
Door position switch/contactor?, Mechanical Lock
Eric
Rectangle
Eric
Oval
Eric
Line
Page 5: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

A3.01

A3.0

A3.1

A3.1

1

2

2

1A4.0

1A4.0

2A4.0

2A4.0

212STUDIO

UNIT B.1 ON A5.2

211STUDIO

UNIT B.1 ON A5.2

210STUDIO

UNIT B.1 ON A5.2 209STUDIO

UNIT B.4 ON A5.3

208STUDIO

UNIT A.5 ON A5.1

207STUDIO

UNIT A.2 ON A5.1

215STUDIO

UNIT B.2 ON A5.2

201STAIR B

200STAIR A

202ELEV

204STUDIO

UNIT A.5 ON A5.1

205STUDIO

UNIT A.1 ON A5.1

206STUDIO

UNIT A.2 ON A5.1

216STUDIO

UNIT B.2 ON A5.2217

STUDIOUNIT B.5 ON A5.3214

STUDIOUNIT D.1 ON A5.3

203CORR.

59' -

4"

23' -

4"

15' -

3"

20' -

9"

13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"

AWNINGBELOW(SBO)

201

200

A

J

J

J

H

H

GA

A

B

A

E.5

E.1

5

5

AA

BB

C C

D D

E

E

F F

6

62

2

A7.25

K K K K

K K K K K

1

1

3

3

4

4

2A-FE

213STUDIO

UNIT C.2 ON A5.3

A7.14

3A8.0

1A8.0

2A8.0

EXIT

EXIT

EXIT

EXIT

24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"

1' - 6"

17' -

2"

6' -

0"12

' - 1

0"7'

- 2"

19' -

1"

5'-0" CLR.

5'-0

" CLR

.

5'-0" CLR.

57' - 2" 5' - 3" 23' - 9"

65' -

2"

86' - 2"

13' -

1"

12' -

11"

13' -

0"

13' -

1"

13' -

1"

48' - 7" 23' - 9"

15' - 2" 10' - 10" 10' - 10" 11' - 9" 8' - 1" 5' - 9"

2' -

11"

128' - 3"T.O. F.F.ELEV:

B4 B4B4

E4

E4

E4

B4B4

B4 B4

C2E4

E4

E4

E4

C2

C1

B6

B6

B3

B6B6

E4

E4E4E4

E4

E4

B4

B4

B4

B4

E3

C1

A9.79

5'-0" CLR.

UP

UP

CHASE TERMINATESUNDER LEVEL 3COUNTER. SEE UNITD.2 ON A5.3 FORLEVELS 4-7.

B7

A9.43

A9.715

5A5.4

4A8.0

A 3.1

1

A 3.0

A 3.0

A 3.1 2

A9.21

AFFORDABLEHOUSING UNIT

A9.49

SIM

A9.410

A9.24

A9.113

A9.61

A9.22

1' -

3"

A9.113

WALL TYPE + SOFFIT KEY

2-HR FIRE-RATED WALL

CONCRETE WALL

CMU WALL

STEEL OR WOOD STUD WALL

SOFFIT/LOWERED CEILING

SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY

INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL

GENERAL FLOOR PLAN NOTES:

• NICHOLSON KOVALCHICK ARCHITECTS

310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154

www.nkarch.com

2013 NICHOLSON KOVALCHICK ARCHITECTS PSC

FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:

REVISIONS

ISSUANCE

#

A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13

A2.2

115205.22.2013

SL, AMMG1152_TRIAD 12TH

FLOOR PLAN -LEVEL 2

TRIA

D 1

2TH

AVE

NU

E41

19 &

412

3 12

TH A

VEN

UE

NE

SEAT

TLE,

WA

9810

5

TRIA

D C

APIT

AL

SCALE: 1/8" = 1'-0"LEVELS 2 (TYPE 1A)1

NORTH

UNIT AREAS - LEVEL 2UNIT NET SF GROSS SF

204 260 SF 319205 274 SF 316206 274 SF 316207 274 SF 316208 257 SF 317209 256 SF 304210 259 SF 296211 259 SF 296212 259 SF 296213 280 SF 346214 257 SF 330215 258 SF 298216 259 SF 296217 254 SF 318

1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.136 ADDENDUM 1 08.27.136

Eric
Oval
Eric
Oval
Eric
Line
Eric
Line
Page 6: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

A3.01

A3.0

A3.1

A3.1

1

2

2

1A4.0

1A4.0

2A4.0

2A4.0

312STUDIO

UNIT B.1 ON A5.2

311STUDIO

UNIT B.1 ON A5.2

310STUDIO

UNIT B.1 ON A5.2309

STUDIOUNIT B.4 ON A5.2

308STUDIO

UNIT A.4 ON A5.1

307STUDIO

UNIT A.2 ON A5.1

301STAIR B

300STAIR A

302ELEV

303CORR.

305STUDIO

UNIT A.1 ON A5.1

304STUDIO

UNIT A.4 ON A5.1

306STUDIO

UNIT A.2 ON A5.1

316STUDIO

UNIT B.2 ON A5.2

317STUDIO

UNIT B.6 ON A5.3

314STUDIO

UNIT D.1 ON A5.3

59' -

4"

23' -

4"

15' -

3"

20' -

9"

13' - 8" 10' - 10" 10' - 10" 10' - 10" 11' - 0"

57' - 2" 5' - 3" 23' - 9"

13' -

1"

13' -

1"

13' -

1"

13' -

1"

12' -

11"

7' -

5"

301

300

B

A

E.2

A

J

J

J

J

A

A

E.1

A7.15

5

5

AA

BB

C C

D D

E

E

F F

6

62

2

A7.26

K K K K

K K K K K

1

1

3

3

4

4

2A-FE

313STUDIO

UNIT C.3 ON A5.3

3A8.0

1A8.0

2A8.0

EXIT

EXIT

EXIT

EXIT

5'-0" CLR.

5'-0

" CLR

.

5'-0" CLR.

4' - 10 1/2"

15' - 2" 10' - 10" 10' - 10" 11' - 9" 8' - 1" 5' - 9"

24' - 6" 24' - 1" 13' - 10" 14' - 9" 9' - 0"

86' - 2"

48' - 7" 23' - 9"

19' -

1"

7' -

2"12

' - 1

0"6'

- 0"

17' -

2"

I

E2E2

E1

E1

E2

E2

E2

E1

E2E2

E1

E1

E3

E3E3

A4

A4

A4

A6

A3

A6A6

A5 B8

E3

A5

E3

E3

A6

A6

A3A4 A4 A4 A4

E2E1E2

A4

A4

A4

A4315

STUDIOUNIT B.2 ON A5.2

UP

UP

A9.44A9.4

10A9.6

1

A9.715

5A5.4

SEE UNIT A.6ON SHEET A5.1FOR UNITS 406+ 706 ONLEVELS 4 + 7

12" M

IN.

12" M

IN.

7' -

2"

4A8.0

A 3.1

1

A 3.0

A 3.0

A 3.1 2

7' -

2"

1' - 2 3/4"

1' - 2 3/4"

AFFORDABLEHOUSING UNIT

317

A9.21

A9.22

A9.23

CHASE TERMINATESUNDER LEVEL 3COUNTER. SEE UNITD.2 ON A5.3 FORLEVELS 4-7.

J

WALL TYPE + SOFFIT KEY

2-HR FIRE-RATED WALL

CONCRETE WALL

CMU WALL

STEEL OR WOOD STUD WALL

SOFFIT/LOWERED CEILING

SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY

INSULATE PERIMITER CONCRETECOLUMNS PER DETAIL

GENERAL FLOOR PLAN NOTES:

NICHOLSON KOVALCHICK ARCHITECTS

310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154

www.nkarch.com

2013 NICHOLSON KOVALCHICK ARCHITECTS PSC

FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:

REVISIONS

ISSUANCE

#

A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13

A2.3

115205.22.2013

SL, AMMG1152_TRIAD 12TH

FLOOR PLAN -LEVELS 3-7

TRIA

D 1

2TH

AVE

NU

E41

19 &

412

3 12

TH A

VEN

UE

NE

SEAT

TLE,

WA

9810

5

TRIA

D C

APIT

AL

NORTH

SCALE: 1/8" = 1'-0"LEVELS 3-7 (TYPE V)1

UNIT AREAS - LEVELS 3-7UNIT NET SF GROSS SF

LEVEL 3304 274 SF 319305 280 SF 316306 279 SF 316307 279 SF 316308 271 SF 317309 260 SF 304310 261 SF 296311 262 SF 296312 262 SF 296313 294 SF 349314 262 SF 330315 261 SF 298316 261 SF 296317 272 SF 320LEVEL 4404 274 SF 319405 280 SF 316406 264 SF 300407 280 SF 316408 271 SF 316409 261 SF 317410 263 SF 304411 263 SF 296412 263 SF 296413 297 SF 349414 279 SF 330415 261 SF 298416 262 SF 296417 273 SF 320LEVEL 5504 274 SF 319505 281 SF 316506 281 SF 316507 281 SF 316508 271 SF 317509 261 SF 304510 263 SF 296511 263 SF 296512 263 SF 296513 297 SF 349514 279 SF 330515 261 SF 298516 262 SF 296517 273 SF 320LEVEL 6604 274 SF 319605 281 SF 316606 281 SF 316607 281 SF 316608 271 SF 317609 261 SF 304610 263 SF 296611 263 SF 296612 262 SF 296613 297 SF 349614 278 SF 330615 260 SF 298616 263 SF 296617 273 SF 320LEVEL 7704 274 SF 319705 281 SF 316706 279 SF 316707 281 SF 316708 271 SF 317709 261 SF 304710 263 SF 296711 263 SF 296712 262 SF 296713 297 SF 349714 279 SF 330715 260 SF 298716 262 SF 296717 274 SF 320

274 SF

264 SF

1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.136 ADDENDUM 1 08.27.13

6

Eric
Oval
Eric
Oval
Eric
Line
Eric
Line
Page 7: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

A3.01

A3.0

A3.1

A3.1

1

2

2

1A4.0

1A4.0

2A4.0

2A4.0

R03CONTROL RM.

R04ELEV LOBBY

R00STAIR A

R01STAIR B

7' -

7"12

' - 2

"16

' - 8

"28

' - 1

0"

6' -

8 1/

2"9'

- 11

1/2

"

R05

MECH.ROOM

R02ELEV

86' - 2"

24' - 6" 24' - 2" 13' - 9" 23' - 9"

57' - 5" 5' - 3" 23' - 11"

65' -

3"

14' -

9"

23' -

9"

59' -

8"

189' - 4"T.O. PARAPETELEV.

189' - 4"T.O. PARAPETELEV.

26' - 9"

802801

800

A7.16

5

5

AA

BB

D D

F F

6

62

2

A7.27

1

1

3

3

4

4

2A-F

E

3A8.0

E2E2 E1E1

185' - 4"T.O.F.F.ELEV:

A5A5B8

GREEN ROOF

GREEN ROOF

RIDGE

VALLEY

VALL

EY

EXIT

TENANT ROOF DECK1626 SF

T.O. ROOF @ DRAINELEV: 184' - 4.5"

T.O. ROOF @HIGHEST POINTELEV: 185' - 0.5"

T.O. ROOF @HIGHEST POINTELEV: 184' - 11.25"

T.O. ROOF @HIGHEST POINTELEV: 184' - 10.25"

T.O. ROOF @ DRAINELEV: 184' - 4.5"

T.O. ROOF @HIGHEST POINT

ELEV: 184' - 10.25" T.O. PARAPETELEV:

T.O. ROOF @HIGHEST POINT

ELEV: 184' - 6"

1/4"

: 12

"1/

4" :

12" 1/4" : 12"

1/4" : 12"

1/4" : 12"

1/4"

: 12

"

E2

RID

GE

T

SA9.715

26' -

3"

18' -

10"

17' -

2"

7' - 2 3/4" 9' - 3" 10' - 3 1/4"

42" GUARD RAIL

42" GUARD RAIL

42" GUARD RAIL

189' - 4"

A3.03

A3.0

4

A3.1 3

A3.1

4

185' - 4"T.O. ROOF DECKELEV:

4A8.0

EXIT

A 3.1

1

A 3.0

A 3.0

A 3.1 2A5

A5

42" GUARD RAIL

A

B

D

3

195' - 9"

T.O. ELEVATORELEV:

T.O. VESTIBULEELEV:

T.O. PARAPETELEV:

1/4 : 12"

1/4

: 12"

26' - 9"

7' - 2" 9' - 0" 10' - 7"

16' -

8"

6' -

8 1/

2"9'

- 11

1/2

"

A3.03

A3.0

4

A3.1 3

A3.1

4

1' - 0" 10' - 5"

11' - 5"

18' -

11

1/2"

WALL TYPE + SOFFIT KEY

2-HR FIRE-RATED WALL

CONCRETE WALL

CMU WALL

STEEL OR WOOD STUD WALL

SOFFIT/LOWERED CEILING

SOFFIT/LOWERED CEILING @CONCRETE CEILING ONLY

NICHOLSON KOVALCHICK ARCHITECTS

310 FIRST AVENUE S, SUITE 4SSEATTLE, WASHINGTON 98104T: 206.933.1150 F: 206.933.1154

www.nkarch.com

2013 NICHOLSON KOVALCHICK ARCHITECTS PSC

FILE NAME:CHECKED BY:DRAWN BY:PROJECT #:DATE:

REVISIONS

ISSUANCE

#

A MUP SUBMITTAL 05.03.12B BP SUBMITTAL 11.08.12C PRICING SET 03.08.13D 100% CD'S 05.22.13

A2.4

115205.22.2013

SL, AMMG1152_TRIAD 12TH

FLOOR PLAN - ROOF

TRIA

D 1

2TH

AVE

NU

E41

19 &

412

3 12

TH A

VEN

UE

NE

SEAT

TLE,

WA

9810

5

TRIA

D C

APIT

AL

SCALE: 1/8" = 1'-0"ROOF PLAN1

NORTH

SCALE: 1/8" = 1'-0"UPPER ROOF2

1 MUP CORRECTION 09.10.123 BP CORRECTION 02.28.134 BP CORRECTION 2 04.24.136 ADDENDUM 1 08.27.13

6

Eric
Oval
Eric
Oval
Eric
Oval
Eric
Oval
Eric
Oval
Eric
Oval
Eric
Line
Eric
Line
Eric
Line
Eric
Line
Eric
Line
Eric
Line
Eric
Text Box
FOB
Page 8: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

Better performance indoor dome

www.samsung-security.com05-2011

• High resolution of 600TV lines, 700TV lines (B/W)• Min. illumination [email protected] (Color), 0.001Lux (B/W)• 2.4x V/F lens (2.5 ~ 6mm)• Electronic Day/Night• MD, SSNRIII (3D+2D), Dual power (24VAC/12VDC)• Pelco "C" Coax Control• Available in Black (SCD-2060EB)

SCD-2060EHigh Resolution Varifocal Dome Camera

Equipped with Samsung's latest W-V DSP chipset, the SCD-2060E achieves vivid images at 600TV lines resolution. With low light levels of 0.15lux, it delivers clear images even at night. The SCD-2060E has a 3.6x varifocal lens (2.8 ~ 10mm) which provides maximum flexibility for installation. In addition there is built-in coaxial control compatibility, MD and SSNRⅢ function for improved performance.

Page 9: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

SCD-2060EN SCD-2060EP

VIDEO

Imaging Device 1/3" Super HAD CCD

Total Pixels 811(H) x 508(V) 795(H) x 596(V)

Effective Pixels 768(H) x 494(V) 752(H) x 582(V)

Scanning System 2 : 1 Interlace

Synchronization Internal / Line lock

Frequency H : 15.734KHz / V : 59.94Hz H : 15.625KHz / V : 50Hz

Horizontal Resolution Color : 600TV lines, B/W : 700TV lines

Min. Illumination Color : [email protected] (50IRE), 0.0003Lux (Sens-up, 512x)

S / N Ratio 52dB (AGC off, Weight on)

Video Output CVBS : 1.0 Vp-p / 75Ω composite

LENS

Focal Length (Zoom Ratio) 2.8 ~ 10mm (3.6x) : SCD-2080E, 2.5 ~ 6mm (2.4x) : SCD-2060E

Max. Aperture Ratio 1 : 1.2(Wide) ~ 2.8(Tele)

Angular Field of ViewH : 94.4°(Wide) ~ 28°(Tele) / V : 69.2°(Wide) ~ 21°(Tele) : SCD-2080E

H : 103.4˚(Wide) ~ 46.6˚(Tele) / V : 77.6˚(Wide) ~ 35.1˚(Tele) : SCD-2060E

Lens Type DC auto iris

Mount Type Board type

PAN / TILT

Pan Range 0° ~ 352°

Tilt Range 0° ~ 73°

Rotate Range 0° ~ 348°

OPERATIONAL

On Screen DisplayEnglish, Japanese, Spanish, French,

Portuguese, Taiwanese, Korean

English, French, German, Spanish, Italian,

Chinese, Russian, Polish, Czech, Romanian,

Serbian, Swedish, Danish, Turkish, Portuguese

Camera Title Off / On (Displayed 15 characters)

Day & Night Auto (Electrical ) / Color / B/W

Backlight Compensation BLC / HLC / Off

Contrast Enhancement SSDR (Off / On)

Digital Noise Reduction SSNRIII (Off / On)

Digital Image Stabilization Off / On

Motion Detection Off / On (8 programmable zones)

Privacy Masking Off / On (12 programmable zones)

Sens-up (Frame Integration) 2x ~ 512x

Gain Control Off / Low / High

White Balance ATW / Outdoor / Indoor / Manual / AWC (1,700K° ~ 11,000K°)

Electronic Shutter Speed 1/60 ~ 1/120,000sec 1/50 ~ 1/120,000sec

Digital Zoom Off / On (1x ~ 16x)

Flip Vertical / Horizontal

Communication Coaxial control

Protocol Coax : Pelco-C (Coaxitron)

ENVIRONMENTAL

Operating Temperature / Humidity -10°C ~ +50°C (+14°F ~ +122°F) / Less than 90% RH

ELECTRICAL

Input Voltage Dual (24V AC & 12V DC ±10%)

Power Consumption Max. 3.5W

MECHANICAL

Color / Material Ivory or Black / Plastic

Dome COver Clear

Dimensions (WxH) Ø115.8 x 92.7mm (Ø4.56" x 3.65")

Weight 345g (0.76 lb) Also available in black : SCD-2080EB/2060EB

High Resolution Varifocal Dome Camera

SCD-2060E

Specifications

M.E-1009

DISTRIBUTED BY

Dimensions Unit : mm (inch)

92.7

(3.6

5")

Ø115.8 (4.56")

SCD-2060E

SCD-2060EB

Design and specifications are subject to change without notice.

The Eco mark represents Samsung Techwin’s will to create environment-friendly products,and indicates that the product satisfies the EU RoHS Directive.

SAMSUNG TECHWIN AMERICA Inc.100 Challenger Road, Suite 700, Ridgefield Park, NJ 07660, UNITED STATESTol Free : 1-877-213-1222 Fax : 1-201-373-0124www.samsungsecurityusa.com

Page 10: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

Electronic Interconnected LocksetComputer Managed Locking System

Introducing the Schlage FE210F electronic interconnect, the newest addition to the line of computer managed locks for multi-family applications. Designed for both new construction and retrofit projects, the electronic interconnect offers the latest in design choice and ease of installation.

To meet the demands of residents, the electronic interconnect is available with several new features:

• A full variety of commercial and all residential levers fit the FE210F

• Increased suiting opportunities with unit interior hardware

• Available in split lever designs and finishes

• Select levers are code compliant with return to door requirements

• The interconnect mechanism is adjustable

Computer managed locksets offer significant advantages. • iButton credentials make key duplication impossible

• “Rekey” the lock without removing the lock from the door

Using Schlage Security Management System Express (SMS Express) software, the FE210F can:

• Generate audit reports showing date & time stamped access to all areas of the community

• Allow time zone access and auto-unlocking of openings

The FE210F delivers the latest features in security innovation to give both you and your residents the peace of mind that comes with real security.

Benefits • Single motion egress meets Life & Safety code requirements

• Eliminates unauthorized key duplication

• Eliminates re-keying costs

• Reduces property liability

Markets • Apartment Communities

• Assisted Living Communities

• Student Housing

• Military Housing

Page 11: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

Features • Time & Date controlled access • 1,000 event audit trail� • Manage up to 500 users� • Interconnect mechanism is adjustable� • Lever trim is non-handed and field reversible� • Split finishes and designs are available� • Battery powered – no hard wiring required� • Hidden back-up mechanical key override� • Uses SMS Express software (required, sold separately)� • SMS Express software allows for multiple time zones, auto unlocks and holidays

Specifications • ANSI/BHMA Grade 2 certified • UL Rating – UL 3hr. rating is standard • Latch – UL latch comes with 1” x 2-1/4” square and

round corner faceplate (square corner standard, round corner included in package). 1” edge bore required.

• Strikes – 1-1/8” x 2-3/4” square corner deadbolt strikes and 2-1/4“ x 1-5/8” square corner full lip latch strike reinforcer. Dust box not included.

• Backset – Adjustable backset, fits 2-3/8” or 2-3/4” backsets • Levers – All lever trim is non-handed and field reversible • Stile width – Minimum 4-1/2“ for 2-3/8” backset,

minimum 5“ stile for 2-3/4”. To ensure proper fit, use the dimensions below

• Return to Door – Saturn (SAT) and Neptune (NEP) are return to door code compliant

• Cylinder – 5 pin solid brass, keyed 5-pin, C keyway, keyed different (KD)

• Keys – 5-pin, C section • Door Range – 1-3/8” to 1-3/4” standard. 1-3/4“

to 2 optional. Must be specified • Center to Center – Fits 4” or 5-1/2” center to center

door preps. • Battery – 9v battery included • Credential – Deadbolt is operated using iButton

credential (sold separately)

©2010 Ingersoll-Rand Company, MR-1967

Style Options

Minimum Stile Recommendation

2-3/4” Backset 2-3/8” Backset

Merano Jazz Elan

St. AnnesCallington Champagne

Neptune

Avila

Saturn AvantiFlair JupiterManhattan

Latitude

Lever Options Finish Options

626Satin Chrome

625Bright Chrome

619Satin Nickel

716/643eAged Bronze

609Antique Brass

605Bright Brass

Camelot Plymouth

5.0” Minimum 4.5” Minimum

Page 12: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

Schlage’s keyfobs provide the convenience of either contactless smart card technology or proximity technology in a form that can optionally include an iButton® credential. This durable combination works well in environments that do not require photo ID badging. The ability to attach the keyfob to a key ring ensures that personnel will be less likely to forget or lose their access credential.

The combination of either smart card technology or proximity technology with an iButton® provides the ideal dual credential for organizations that have integrated multiple credential technologies into their facilities. The iButton® provides a registration number used for access control in legacy systems, and the proximity or smart card technology enables future expansion with more advanced credentials.

The proximity keyfob incorporates the convenience of proximity technology with the iButton®. The smart keyfob can support diverse applications such as access control, biometrics, cashless vending, transit applications, and many more.

Proximity &Smart Keyfobswith iButton® Option

Smart Keyfob Features

• 13.56 MHz frequency Smart Technology• Available with two memory and technology

configurations • 1K bit (8K byte) MIFARE® or a 4K bit (32K

byte) MIFARE DESFire™ EV1*• Data transfer rates of up to 848 kbps

Proximity Keyfob Features

• 125 kHz proximity technology

iButton® Features

• Durable stainless-steel packaging • Unique factory programmed 64-bit

registration number• Momentary contact initiates identification

• Data transfer rate of up to 16.3 kbps

* Factors affecting read range include installation conditions such as voltage, location of power supply and mounting material.

Cre

dent

ials

Prox

imity

and

Sm

art

Keyf

obs

Page 13: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

877-671-7011 • securitytechnologies.ingersollrand.com

ORDERING INFORMATION

Part Number** IBF-110 (Combo iButton® keyfob with 125 KHz Prox)

IBWB-110 (125 KHz Prox keyfob without iButton®)

IBF-151 (Combo iButton® keyfob with 8K bit/1K byte MIFARE®)

IBWB-151 (8K bit/1K byte MIFARE® keyfob without iButton®)

** Standard part numbers. See ordering guide for more configurations and part numbers. Specifications subject to change without notice.

INGERSOLL RAND, the Ingersoll Rand logo, SCHLAGE and the SCHLAGE logo, are trademarks of Ingersoll-Rand plc, its subsidiaries and/or affiliates in the United States and other countries. MIFARE and MIFARE DESFire EV1 are trademarks of NXP B.V. All other trademarks are the property of their respective owners.

©2013 Ingersoll Rand 004227 04/13

Keyfob Specifications

Dimensions(At widest point)

2.24” x 1” x 0.60”5.7 cm x 2.52 cm x 1.48 cm

Weight 0.20 oz. (5.6 g)

Maximum Read Range* Up to 4”

AD

-Ser

ies

PR Reader Module up to 0.75”PRK Reader Module up to 0.75”SM Reader Module up to 0.75”SMK Reader Module up to 0.75” MT Reader Module up to 0.75”MTK Reader Module up to 0.75”

Frequency 125 KHz or 13.56 MHz (see below for part numbers)

Operating Temperature -50° to 160° F (-45° to 70° C)

Material Polycarbonate

Color Gray

* Factors affecting read range include installation conditions such as voltage, location of power supply and mounting material.

Page 14: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

Schlage’s keyfobs provide the convenience of either contactless smart card technology or proximity technology in a form that can optionally include an iButton® credential. This durable combination works well in environments that do not require photo ID badging. The ability to attach the keyfob to a key ring ensures that personnel will be less likely to forget or lose their access credential.

The combination of either smart card technology or proximity technology with an iButton® provides the ideal dual credential for organizations that have integrated multiple credential technologies into their facilities. The iButton® provides a registration number used for access control in legacy systems, and the proximity or smart card technology enables future expansion with more advanced credentials.

The proximity keyfob incorporates the convenience of proximity technology with the iButton®. The smart keyfob can support diverse applications such as access control, biometrics, cashless vending, transit applications, and many more.

Proximity &Smart Keyfobswith iButton® Option

Smart Keyfob Features

• 13.56 MHz frequency Smart Technology• Available with two memory and technology

configurations • 1K bit (8K byte) MIFARE® or a 4K bit (32K

byte) MIFARE DESFire™ EV1*• Data transfer rates of up to 848 kbps

Proximity Keyfob Features

• 125 kHz proximity technology

iButton® Features

• Durable stainless-steel packaging • Unique factory programmed 64-bit

registration number• Momentary contact initiates identification

• Data transfer rate of up to 16.3 kbps

* Factors affecting read range include installation conditions such as voltage, location of power supply and mounting material.

Cre

dent

ials

Prox

imity

and

Sm

art

Keyf

obs

Page 15: FIELD REPORT - Pavilion Construction · PROJECT NAME: 12. th. Avenue Apartments PROJECT NUMBER: 1343 . 4119 & 4123 12. th. Avenue . Seattle, WA DATE OF ISSUANCE: April 1, 2014 . OWNER:

877-671-7011 • securitytechnologies.ingersollrand.com

ORDERING INFORMATION

Part Number** IBF-110 (Combo iButton® keyfob with 125 KHz Prox)

IBWB-110 (125 KHz Prox keyfob without iButton®)

IBF-151 (Combo iButton® keyfob with 8K bit/1K byte MIFARE®)

IBWB-151 (8K bit/1K byte MIFARE® keyfob without iButton®)

** Standard part numbers. See ordering guide for more configurations and part numbers. Specifications subject to change without notice.

INGERSOLL RAND, the Ingersoll Rand logo, SCHLAGE and the SCHLAGE logo, are trademarks of Ingersoll-Rand plc, its subsidiaries and/or affiliates in the United States and other countries. MIFARE and MIFARE DESFire EV1 are trademarks of NXP B.V. All other trademarks are the property of their respective owners.

©2013 Ingersoll Rand 004227 04/13

Keyfob Specifications

Dimensions(At widest point)

2.24” x 1” x 0.60”5.7 cm x 2.52 cm x 1.48 cm

Weight 0.20 oz. (5.6 g)

Maximum Read Range* Up to 4”

AD

-Ser

ies

PR Reader Module up to 0.75”PRK Reader Module up to 0.75”SM Reader Module up to 0.75”SMK Reader Module up to 0.75” MT Reader Module up to 0.75”MTK Reader Module up to 0.75”

Frequency 125 KHz or 13.56 MHz (see below for part numbers)

Operating Temperature -50° to 160° F (-45° to 70° C)

Material Polycarbonate

Color Gray

* Factors affecting read range include installation conditions such as voltage, location of power supply and mounting material.