fan upgrade service - skf.com€¢progressive type system: • applications requiring more lubricant...

34

Upload: tranngoc

Post on 17-Apr-2018

217 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of
Page 2: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 2 [Code] SKF [Organisation]

Fan upgrade serviceEurope: lubrication systems

SKF Industrial Fans

Page 3: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 3 [Code] SKF [Organisation]

Lubrication System Terms

Total-loss lubrication systems (typ grease lubrication systems):

Circulating lubrication systems:

Filtered, temperature controlled oil is pumped through the friction points and returned back to the reservoir via the return lines. As long as the lubricated machinery operates the oil is circulated.

The lubricant is fed to the friction points only once. It passes through the friction points and is not automatically collected nor used again.Continuous or intermittent lubrication.

Page 4: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 4 [Code] SKF [Organisation]

Lubrication: Grease vs Oil

Pros and cons with grease: Pros and cons with oil:

+ Easy to retain in the housing + Wide operating temperature range

+ Good sealing function in labyrinths + Can be re-circulated (“reused”)

+ Less costly lubrication system + Can be filtered and cooled

+ Long bearing service life

- Cannot be re-circulated (“reused”) + Most effective lubrication

- Cannot be filtered and cooled - More costly lubrication system

- Cannot be cleaned - More complicated seals

- Limited temperature range

- Leakage of used grease

Page 5: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 5 [Code] SKF [Organisation]

Centralized grease lubrication system

Centralized grease lubrication systems are used for:

�Improved reliability

� Correct lubrication at correct intervals

� Reduce contamination

�Reduced costs

� Reduce failures and downtime

� Reduce lubrication costs

�Improved safety

� Reduce exposure to dangerous locations

�Environmatal reasons:

� Reduce lubricant use and spillage

Page 6: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 6 [Code] SKF [Organisation]

SKF centralized grease lubrication systems for fans

SKF recommends the following systems:

•Progressive type system:

• Applications requiring more lubricant and using system 24 causes too much service work

• Bundle of 1-3 small fans close to each other

• No adjustment required (individual points)

•Dual line system:

• When lubrication point need be individually adjusted after the installation

• For large areas with several fans

• For colder environment with potentially long piping runs

Page 7: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 7 [Code] SKF [Organisation]

Centralized Lubrication Systems

How system works:

• The system consists of a pump, a progressive feeder and a control unit.

• The amount of lubricant delivered by the pump is• divided up by the progressive feeder and fed to the

lube points.

• The lubricant is metered out via pistons.

• Each piston can discharge its lubricant only after the preceding one has discharged its.--> simple monitoring of lubricant delivery

Progressive systems

Page 8: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 8 [Code] SKF [Organisation]

Progressive type system

Electrically operated pump with a self contained reservoir and controller

Page 9: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 9 [Code] SKF [Organisation]

Benefits of progressive systems

• Dual line system is most reliable: Compatible with most greaseses(progressive

lube systems more sentitive to separation)

• Dosing modules are adjustable

•Dosing moduleas have visual indicationswith sensors (LG-Ind) and wide

adjustable operating range

• Central alarms (visual, cellular, DCS) systems available

• Monitoring can be accomplished via GSM capability

• Compact, easy to install unit

• Heated reservoir (standard) and lines (heat trace)

Page 10: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 10 [Code] SKF [Organisation]

Centralized Lubrication Systems

Dual-line systems

How system works:

• The two main lines are alternately pressurized.• The metering valves operate by the pressure

generated by the pump • There is a control and metering piston in each

metering valve (no springs required) • One metering valve can serve two lubrication

points

Page 11: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 11 [Code] SKF [Organisation]

Dual line systems, operation principe

Page 12: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 12 [Code] SKF [Organisation]

Small dual line systems; SKF Multilube

Video

Self contained pump with a

controller and monitoring featuresAdjustable dosing modules, sized per individual

bearing needs. Dosing modules and bolted onto

manifolds that are installed within 5-6 meters

from the points

Page 13: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 13 [Code] SKF [Organisation]

Large size dual-line system; SKF Safegrease 2

• Lubricant pumped directly from standard oil refinery barrel

• Controller and monitoring

• Adjustable dosing modules

• Options:

• multi-channel capability

• electronic dosing module operation monitoring

Page 14: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 14 [Code] SKF [Organisation]

Benefits of a dual line systems

• Dual line system is most reliable grease lubrication systems

• Compatible with most greases (progressive lube systems more sentitive to

separation)

• Dosing modules are adjustable and have visual indicators

• Dosing Modules can be equipped with el monitoring sensors (LG-Ind)

• Central alarms (visual, cellular, DCS) systems available

• Monitoring can be accomplished via GSM capability

• Systems can be easily expanded by added new dosing modules and nec piping

Page 15: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

SKF circulating oil lubrication

2008-06-17 ©SKF Slide 15 [Code] SKF [Organisation]

Page 16: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 16 [Code] SKF [Organisation]

Value proposition and solution

2008-06-17 ©SKF Slide 16 [Code] SKF [Organisation]

2006-03-24 © SKF

Reduce total cost of ownership by increasing reliability and lowering maintenance costs, by a unique combination of bearing units and dedicated lubrication systems.

The SKF solution consists of •self-aligning bearing system•standard SAF, SNL or SONL housings and seals. •lubrication systems

Page 17: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 17 [Code] SKF [Organisation]

Technical impact

Current Situation Value for Customer

Bearing temp.(°C)105 °C 75°C

Fan speed (rpm)

Perform

ance

Circulating lubricating oil system(cooling and filtering system)

Page 18: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 18 [Code] SKF [Organisation]

Circulating lubrication systems

How they work

• Conditioned (de-aerated, dried, filtered, cooled) oil is circulated through the lubrication points.

• The purpose of the system is to lubricate and

very often to to cool the lube point.

Page 19: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 19 [Code] SKF [Organisation]

Circulating lubrication systems

Pumping skid:

Flowmeters

System piping

heater coolerfilterpumps

return pipingreturn piping

pressure pipingpressure piping

Reservoir with heater

Page 20: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 20 [Code] SKF [Organisation]

SM-100 Oil Circulation Unit

Control unit and power supply

Flow meters

Pump

Filters

Cooler

Oil level sight glass

Heater

Oil reservoir

Page 21: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 21 [Code] SKF [Organisation]

SM-100 Oil Circulation Unit: Features

Versatile, modular design

�One or two pumps

�With or without air cooler

�With or without power supply unit with frequency converters

�With or without stand alone control system

�Unique filter cartridge manifold with manual by-pass and pressure relief valves plus instrumentation

� Above cartridge will eliminate several interconnecting pipes, fittings and hoses and potential other maintenance and leakage points

Installation options

�Digital or variable orifice flow meters

� Customized piping engineering and material package

� Installation and start up service

�Optional system piping heating in cold conditions

Page 22: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 22 [Code] SKF [Organisation]

SM-100 Oil Circulation Unit: Benefits

�Complete compact size oil circulating lube system with all necessary functions and options

�Easy to locate and install

�Easy to start-up and use

�Easy to maintain (minimal number of interconnecting pipes, fitting etc)

�No water needed for cooling, No danger of oil leaking to water, No waste water or danger of frozen water lines

�Optional variable frequency drive (VFD) speed controllers for cooling and pumping reducing component and oil wear and considerably saving energy

Page 23: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 23 [Code] SKF [Organisation]

SM-100 Oil Circulation UnitTechnical specification

� Tank volume: 100 liters

� Operating pressure: max. 10 bar

� Oil flow range: 2-7 l/min

� Oil viscosity in operating conditions: 30-1000 CSt

� Oil filtering rate: 5 microns

� ∆P switch (alarm at 2 bar and automatic by-pass at 3 bar)

� Manual by pass valve for on run filter change

� Visual level monitoring with low level switch

� Thermostat controlled heater of oil tank, ∆T 30 deg C/6h

� Outgoing oil temperature and pressure readings

� Variable frequency drive (VFD) air cooler of oil, 4 kW ∆T40 deg C

� Variable frequency drive (VFD) motors for pressure control

� PLC based control unit with main switch, fuse, indication lights,automatic pump change switch and alarm indicators for pressure,tank temperature, dirty filter, low level

� Standard power supply 400VAC/50Hz

Page 24: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 24 [Code] SKF [Organisation]

SM-100 Oil Circulation Unit, system alternatives

OPTIONS

Flow meters, piping materials, installation services

Page 25: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 25 [Code] SKF [Organisation]

Oil circulation for SRB in SONL…

Size range: 517 through 534+5402 15/16 to 5 7/16

Example designation SONL 217-517Seal TSO 517 or TSO 517/2.15/16

Variants: C3, K7, special drillingsDrain holes: G ¾”

Circulating oil through W33

Page 26: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 26 [Code] SKF [Organisation]

Circulating oil from the side

Oil circulation for CARB in SONL…RA

Size range: 517 through 532 + 5402 15/16 to 5 7/16

Example designation SONL 217-517 RASeal TSO 517 or TSO 517/2.15/16

Variants: C3, K7, special drillingsDrain holes G3/4”

Page 27: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 27 [Code] SKF [Organisation]

Oil circulation for SRB in SNL…TURT

Housing and seals supplied only as a unit

Unit range: size 34 – 96

Example designations

SNL 3136 TURT

SNL 3036 TURT

Seal type: oil seal TSD..U

Variants: C3, K7, inch sizes,

special drillings

Page 28: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 28 [Code] SKF [Organisation]

Oil circulation for CARB in SNL…TURA

Housing and seals supplied only as a unit

Unit range: size 34 – 96 for 31 series

size 36 – 96 for 30 series

Example designations

SNL 3136 TURA

SNL 3036 TURA

Seal type: oil seal TSD..U

Variants: C3, K7, inch sizes,

special drillings

Page 29: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 29 [Code] SKF [Organisation]

SF05/10/15 Oil Flowmeter

Page 30: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 30 [Code] SKF [Organisation]

Safeflow features and benefits

Solid, One Piece Aluminium Body

� Does not leak

� Makes installation easy

� No interconnecting fittings

� Total installation cost lower

� Compact

� Easier to monitor

� Easier to build a panel around

� Treads do not strip

� Body will not change due to environment

Page 31: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 31 [Code] SKF [Organisation]

Oil flow calcualtion program

• An oil flow calculation program will be

available.

• In the meantime will Galaxy BeaTemp be the

calculation tool to determine the required oil

flow.

Page 32: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

Solution summary

2008-06-17 ©SKF Slide 32 [Code] SKF [Organisation]

Page 33: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

Heat, the limiting factorSKF solution summary

2008-06-17 ©SKF Slide 33 [Code] SKF [Organisation]

• SNL Housing,grease lubrication and low friction seals

• Automatic grease lubrication sytems

• Oil bath lubrication, SONL

• Circulating oil lubrication system

• Engineering service,

• e.g. Cooling disc, Galaxy, BeaTemp

• Lubricant selection,

• SYSTEM 24

• The appropriate grease, amount and method

LubeSelect

Page 34: Fan upgrade service - SKF.com€¢Progressive type system: • Applications requiring more lubricant and using system 24 causes too much service work •Bundle of

2008-06-17 ©SKF Slide 34 [Code] SKF [Organisation]

Sales promotion material

2008-06-17 ©SKF Slide 34 [Code] SKF [Organisation]

Brochure publication number 6597