ethercat n-smart series library for sysmac studio tech note · ethercat n-smart series library...

3
N-Smart E3NW-DS Distributed Sensor Unit N-Smart E3NX-FA0 and other Sensor Amplifier Units N-Smart E3NW-ECT Sensor Communications Unit for EtherCAT Inter-unit network *1. The Backup and Restore functions of the NJ/NX CPU Unit can back up and restore the parameters for all the E3NW-ECT Sensor Communication Units at once. The addition of this library allows you to back up and restore the parameters for each node individually. *2. This library can be used to back up and restore parameters for each sensor amplifier unit individually, which is not possible with the Backup and Restore functions of the NJ/NX CPU Unit. *3. The DS-Bus is an Omron inter-unit network communications protocol that connects the E3NW-ECT Sensor Communications Unit and E3NW-DS Distributed Sensor Units. E3NW Parameter Backup Stores all the parameters for the specified sensor amplifier unit as a backup file on the SD memory card. E3NW Parameter Restore Restores the parameters stored as a backup file on the SD memory card to the specified sensor amplifier unit. As any unit can be specified, this Function Block can be used to copy the parameters from one sensor amplifier unit to another. NJ/NX Machine Automation Controller NA/NS Programmable Terminal System configuration *3 SD Memory Card Parameters of each communica- tions unit or amplifier unit can be backed up for each product. Easily and quickly change settings for different products just by specify- ing the parameters to restore on the Programmable Terminal. Ethernet EtherCAT N-Smart Series Library Sysmac Library for NJ/NX Machine Automation Controller SYSMAC-XR005 Reduce sensor setting and replacement work at setup, changeover, maintenance, and operation times. Issue 1 It takes time to set up many sensors. Issue 2 Operation rates are low because it takes time to change sensor settings. Issue 3 When a sensor is replaced, time is needed to change settings and setting errors may occur. EtherCAT N-Smart Series Library offers solution! The Parameter Backup Function Block backs up the parameters for each sensor communications unit* 1 or sensor amplifier unit* 2 individually (upload settings from the unit), and the Parameter Restore Function Block restores them individually (download settings to the unit), without connecting to a PC. You can easily change settings for sensor communications units and sensor amplifier units.

Upload: others

Post on 22-May-2020

29 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EtherCAT N-Smart Series Library for Sysmac Studio Tech Note · EtherCAT N-Smart Series Library offers solution! The Parameter Backup Function Block backs up the parameters for each

N-SmartE3NW-DS

Distributed Sensor Unit

N-SmartE3NX-FA0 and other Sensor Amplifier Units

N-SmartE3NW-ECT

SensorCommunicationsUnit for EtherCAT

Inter-unit network

*1. The Backup and Restore functions of the NJ/NX CPU Unit can back up and restore the parameters for all the E3NW-ECT Sensor Communication Units at once.

The addition of this library allows you to back up and restore the parameters for each node individually.

*2. This library can be used to back up and restore parameters for each sensor amplifier unit individually, which is not possible with the Backup and Restore

functions of the NJ/NX CPU Unit.

*3. The DS-Bus is an Omron inter-unit network communications protocol that connects the E3NW-ECT Sensor Communications Unit and E3NW-DS

Distributed Sensor Units.

①② ①E3NW Parameter Backup

Stores all the parameters for the specified sensor

amplifier unit as a backup file on the SD memory

card.

②E3NW Parameter Restore Restores the parameters stored as a backup file

on the SD memory card to the specified sensor

amplifier unit.

As any unit can be specified, this Function Block

can be used to copy the parameters from one

sensor amplifier unit to another.

NJ/NX Machine Automation Controller

NA/NSProgrammable Terminal

System configuration

*3

SD Memory Card

Parameters of each communica-tions unit or amplifier unit can be backed up for each product. Easily and quickly change settings for different products just by specify-ing the parameters to restore on the Programmable Terminal.

Ethernet

EtherCAT N-Smart Series Library

Sysmac Library for NJ/NX Machine Automation Controller

SYSMAC-XR005

Reduce sensor setting and replacement work at setup, changeover, maintenance, andoperation times.

Issue 1 It takes time to set up many sensors.

Issue 2 Operation rates are low because it takes time to change sensor settings.

Issue 3 When a sensor is replaced, time is needed to change settings and setting errors may occur.

EtherCAT N-Smart Series Library offers solution!The Parameter Backup Function Block backs up the parameters for each sensor communications unit*1 or

sensor amplifier unit*2 individually (upload settings from the unit), and the Parameter Restore Function Block

restores them individually (download settings to the unit), without connecting to a PC.

You can easily change settings for sensor communications units and sensor amplifier units.

Page 2: EtherCAT N-Smart Series Library for Sysmac Studio Tech Note · EtherCAT N-Smart Series Library offers solution! The Parameter Backup Function Block backs up the parameters for each

Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT® is registered trademark and patented technology, licensed by Beckho� Automation GmbH, Germany.EtherNet/IP™ is a trademark of the ODVA.Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

Note: Do not use this document to operate the Unit.

NJ/NX Machine Automation Controller

E3NW-ECT Sensor Communications Unitfor EtherCAT

E3NX-FA0 and other Sensor Ampli�er Units

Sysmac Studio

NJ/NX Machine Automation Controller

NX701-□□□□/NJ101-□□□□

NJ501-□□□□/NJ301-□□□□

SYSMAC-SE2□□□

Version 1.10 or later

Version 1.01 or later

Version 1.14 or higher

Version 1.03 or later

NameCompatible Models

Model Version

Machine Automation Controller NJ/NX CPU Unit

Automation Software Sysmac Studio

Sensor Communications Unit (EtherCAT)

Distributed Sensor Unit

Smart Laser Ampli�er Unit

Smart Laser Ampli�er Unit (CMOS type)

Smart Fiber Ampli�er Unit

Contact-Type Smart Ampli�er Unit

SD Memory Card

Downloading settings when replacing a sensor amplifier unit

From To

FB nameFunction Block (FB) Specifications

Name Description

Backup_E3NW

Restore_E3NW

E3NW Parameter Backup Backs up the parameters for the sensor ampli�er unit that is connected to an E3NW-ECT Sensor Communications Unit or E3NW-DS Distributed Sensor Unit and stores them on the SD memory card inserted into the controller.

E3NW Parameter RestoreRestores the backup data on the SD memory card to the sensor ampli�er unit that is connected to an E3NW-ECT Sensor Communications Unit or E3NW-DS Distributed Sensor Unit.

E3NW-ECT Sensor Communications Unitfor EtherCAT

E3NX-FA0 and other Sensor Ampli�er Units

E3NW-ECT

E3NW-DS

E3NC-LA0

E3NC-SA0

E3NX-FA0

E3NC-TA0

HMC-SD□□□

SD Memory CardParameters can be restored by operating the programmable terminal. No PC, setting software, or complex procedures that may cause errors is required.

① Manually record parameters to make a procedure manual② Replace a sensor amplifier unit③ Set parameters manually according to the procedure manual

① Store parameters on an SD memory card② Replace a sensor amplifier unit③ Restore the parameters stored on the SD memory card

Page 3: EtherCAT N-Smart Series Library for Sysmac Studio Tech Note · EtherCAT N-Smart Series Library offers solution! The Parameter Backup Function Block backs up the parameters for each

OMRON CANADA, INC. • HEAD OFFICEToronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com

OMRON ELECTRONICS DE MEXICO • HEAD OFFICEMéxico DF • 52.55.59.01.43.00 • 01-800-226-6766 • [email protected]

OMRON ELECTRONICS DE MEXICO • SALES OFFICEApodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • [email protected]

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICESão Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON ARGENTINA • SALES OFFICECono Sur • 54.11.4783.5300

OMRON CHILE • SALES OFFICESantiago • 56.9.9917.3920

OTHER OMRON LATIN AMERICA SALES54.11.4783.5300

Authorized Distributor:

P094-E1-01 11/15 Note: Specifications are subject to change. © 2015 Omron Electronics LLC Printed in U.S.A.

Printed on recycled paper.

Automation Control Systems• Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software

Drives & Motion Controls • Servo & AC Drives • Motion Controllers & Encoders

Temperature & Process Controllers • Single and Multi-loop Controllers

Sensors & Vision• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors• Amplified Photomicrosensors • Measurement Sensors• Ultrasonic Sensors • Vision Sensors

Industrial Components • RFID/Code Readers • Relays • Pushbuttons & Indicators• Limit and Basic Switches • Timers • Counters • Metering Devices • Power Supplies

Safety • Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety

Controllers • Light Curtains • Safety Relays • Safety Interlock Switches

OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu