Error Correction in S ingle- C ell DNA S equencing: Finding R are A llele for MRD C lone Dong Kim 1 , Manimozhi Manivannan 1 , Sombeet Sahu 1 , Shu Wang 1 , Saurabh Gulati 1 , Nianzhen Li 1 , Adam Sciambi 1 and Nigel Beard 1 1 Mission Bio, South San Francisco, CA, USA Conflicts of interest: D.K., M.M., S.S., S.W., S.G., A.S., N.L., A.P., H.V.,N.B. are employees and shareholders of Mission Bio, Inc. Nucleus Abstract Background The Tapestri single-cell DNA sequencing platform contains a small number of errors from polymerase incorporations, structure induced template switching, PCR mediated recombination or DNA-damage, and errors from sequencing. These errors can range from 0.5% to 2% depending on the sequencer. To improve variant calling and minimal residual disease (MRD) detection we developed a novel consensus sequence-based method for correcting the errors and reducing the false-positive rates. Methods Here we present a model to correct base position errors in Tapestri single-cell DNA analytical workflow. The error correction method involves 2 steps. First, we train the model with cell BAM files from multiple panels. A pileup is generated around a mismatch position with k-1/2 bases on both sides. During training, a batch of normalized pileups and true reference bases are feed into NN-based model. For each batch, error is calculated between predicted bases and true reference bases. Gradients of this error are calculated with respect to weights of each layer. The gradients are then used to update the weight of the model in a back propagation step. Once a validation accuracy reaches, the trained model and base transition matrix are used to predict a likelihood of a base on given position. If prediction is the same as reference, the model corrects observed non-reference base to reference base. To filter out the noisy reads before passing the data to variant caller, we suppress the quality scores of reads having very low coverage. To validate this method, we used two different targeted panels on a Latin square model system (4 cell line mixtures with 98.4%, 1%, 0.5% and 0.1% dilutions) with known truth mutations. We ran the Tapestri analytical workflow with and without error correction. With the error correction pipeline, we were able to significantly reduce our false positive rates while maintaining our sensitivity. Results and Conclusions To validate this method, we used two different targeted panels on a Latin square model system with PBMC samples with known truth mutations. We also performed titration experiments of 4 cell line mixtures with 98.4%, 1%, 0.5% and 0.1% dilutions. We processed the samples through Tapestri P latform and sequenced over multiple Illumina sequencers (Hiseq 2500, Miseq). We ran the Tapestri analytical workflow with and without error correction. With the error correction pipeline, we reduced our false positive rates by ~25% while maintaining high sensitivity. Further optimization to improve the sensitivity is currently in progress. Mission Bio Tapestri Workflow Overview Error correction workflow using DNNs Preparing input data for CNN Why Single-Cell ? Complexity of Cancer Evolution Understand Disease at a Single-Cell Level 1 2 a) For each aligned read in a BAM file, a pileup is generated around a mismatch position with n flanking bases to the left and right. b) Frequency of A,C,G, and T for each location in a window. c) Frequencies of each base are normalized by the total number of bases appearing on a given position. Generating substitution matrix P099 Sensitivity and specificity on titration experiment ALT Base REF A T G C A 0.99003 7710 0.002613 237 0.0060924 478 0.0012566 048 T 0.00285 7063 0.989192 132 0.0016163 415 0.0063344 639 G 0.00345 1487 0.001457 358 0.9944835 174 0.0006076 378 C 0.00161 8104 0.003412 833 0.0005897 472 0.9943793 161 a). Substitution rates are calculated by counting number of bases for a given reference base for valid loci. b). We observed significant variation in the substitution rates between runs and hence fixed matrix would not work. Substitution rates starts plateauing after sub sampling 4M reads a) Substitution matrix b) Num of bases vs avg deviation in error Accuracy a). 4 different cell lines PC3, RAJI, DU145 and SKMEL28 were mixed at different titrations. Cells were subsampled randomly from each cell line. Error correction was applied to the reads and data from before and after were analyzed for sensitivity and specificity. ~25% reduction in the total number of variants. before after variant 1 893 893 variant 2 875 877 variant 3 867 234 variant 4 2 2 variant 5 1 1 a) b) a) b) d) before after variant 1 235 234 variant 2 649 651 variant 3 656 186 variant 4 228 226 variant5 19 16 a and c) Two clinical samples were processed through analytical pipeline. Frequency of the variants were counted and compared to before and after error correction. Overall error correction resulted in a decrease in the number of observed variants b and d) The true variants were known from bulk sequencing. 4/5 of the variants showed same sensitivity before and after. There is one variant with low sensitivity. Tapestri Solution Number of Variants b). High sensitivity in most of the variants. There were 3 different FN’s that can be improved by further optimization. Learn more about Mission Bio at our other posters at SCG Poster Session Title P028 24th Doublets Detection in Single Cell DNA-Sequencing using Deep Learning P031 24th Co-detection of mutations and copy number variations in thousands of single-cells using an automated platform P034 24th Using machine learning to optimize assays for single cell targeted DNA sequencing P093 24th Single-cell Simultaneous Detection of DNA Genotype and Protein Expression P099 24th Error Correction in single-cell DNA sequencing: Finding rare allele for MRD clone P109 25th A high throughput single cell workflow for paired genomic and phenotypic analysis P112 25th A triomic single-cell high-throughput microfluidic workflow for resolution of genotype-to-phenotype modalities: parallel analysis of DNA, RNA and protein a) Pileup of mapped reads b) Pileup frequency c) Normalized pileup Reads from sequencer Deep Learning Results on PBMC sample with known truth Cell Supporting Variants c) Number of Variants Cell supporting variants Catalog Panels for Hematology and Solid Tumor nonEC EC nonEC EC 1 2 3 4 5 6 7 8 9 10 11-20 21-30 31-40 41-50 51-100 101-200 201-300 301-400 401-500 901-900 901-1019 501-600 601-700 701-800 1 2 3 4 5 6 7 8 9 10 11-20 21-30 31-40 41-50 51-100 101-200 201-300 301-400 401-500 501-600 601-700 701-794

Upload: others

Post on 12-Jul-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Error Correction in Single-Cell DNA Sequencing · Error Correction in Single-Cell DNA Sequencing: Finding Rare Allele for MRD Clone Dong Kim1, Manimozhi Manivannan1, Sombeet Sahu1,

Error Correction in Single-Cell DNA Sequencing: Finding Rare Allele for MRD Clone

Dong Kim1, Manimozhi Manivannan1 , Sombeet Sahu1, Shu Wang1, Saurabh Gulati1, Nianzhen Li1, Adam Sciambi1 and Nigel Beard1

1 Mission Bio, South San Francisco, CA, USA

Conflicts of interest: D.K., M.M., S.S., S.W., S.G., A.S., N.L., A.P., H.V.,N.B. are employees and shareholders of Mission Bio, Inc.

Nucleus

AbstractBackgroundThe Tapestri single-cell DNA sequencing platform contains a small number of errors from polymerase incorporations, structure induced template switching, PCR mediated recombination or DNA-damage, and errors from sequencing. These errors can range from 0.5% to 2% depending on the sequencer. To improve variant calling and minimal residual disease (MRD) detection we developed a novel consensus sequence-based method for correcting the errors and reducing the false-positive rates. MethodsHere we present a model to correct base position errors in Tapestri single-cell DNA analytical workflow. The error correction method involves 2 steps. First, we train the model with cell BAM files from multiple panels. A pileup is generated around a mismatch position with k-1/2 bases on both sides. During training, a batch of normalized pileups and true reference bases are feed into NN-based model. For each batch, error is calculated between predicted bases and true reference bases. Gradients of this error are calculated with respect to weights of each layer. The gradients are then used to update the weight of the model in a back propagation step. Once a validation accuracy reaches, the trained model and base transition matrix are used to predict a likelihood of a base on given position. If prediction is the same as reference, the model corrects observed non-reference base to reference base. To filter out the noisy reads before passing the data to variant caller, we suppress the quality scores of reads having very low coverage.

To validate this method, we used two different targeted panels on a Latin square model system (4 cell line mixtures with 98.4%, 1%, 0.5% and 0.1% dilutions) with known truth mutations. We ran the Tapestri analytical workflow with and without error correction. With the error correction pipeline, we were able to significantly reduce our false positive rates while maintaining our sensitivity.

Results and Conclusions

To validate this method, we used two different targeted panels on a Latin square model system with PBMC samples with known truth mutations. We also performed titration experiments of 4 cell line mixtures with 98.4%, 1%, 0.5% and 0.1% dilutions. We processed the samples through Tapestri Platform and sequenced over multiple Illumina sequencers (Hiseq 2500, Miseq). We ran the Tapestri analytical workflow with and without error correction. With the error correction pipeline, we reduced our false positive rates by ~25% while maintaining high sensitivity. Further optimization to improve the sensitivity is currently in progress.

Mission Bio Tapestri Workflow Overview

Error correction workflow using DNNs

Preparing input data for CNN

Why Single-Cell ?

Complexity of Cancer Evolution

Understand Disease at a Single-Cell Level

1

2

a) For each aligned read in a BAM file, a pileup is generated around a mismatch position with n flanking bases to the left and right. b) Frequency of A,C,G, and T for each location in a window. c) Frequencies of each base are normalized by the total number of bases appearing on a given position.

Generating substitution matrix

P099

Sensitivity and specificity on titration experiment

ALT Base

REFA T G C

A0.990037710

0.002613237

0.0060924478

0.0012566048

T0.002857063

0.989192132

0.0016163415

0.0063344639

G0.003451487

0.001457358

0.9944835174

0.0006076378

C0.001618104

0.003412833

0.0005897472

0.9943793161

a). Substitution rates are calculated by counting number of bases for a given reference base for valid loci.

b). We observed significant variation in the substitution rates between runs and hence fixed matrix would not work. Substitution rates starts plateauing after sub sampling 4M reads

a) Substitution matrix

b) Num of bases vs avg deviation in error

Accuracy

a). 4 different cell lines PC3, RAJI, DU145 and SKMEL28 were mixed at different titrations. Cells were subsampled randomly from each cell line. Error correction was applied to the reads and data from before and after were analyzed for sensitivity and specificity. ~25% reduction in the total number of variants.

before aftervariant 1 893 893variant 2 875 877variant 3 867 234variant 4 2 2variant 5 1 1

a) b)

a) b)

d) before after

variant 1 235 234variant 2 649 651variant 3 656 186variant 4 228 226variant5 19 16

a and c) Two clinical samples were processed through analytical pipeline. Frequency of the variants were counted and compared to before and after error correction. Overall error correction resulted in a decrease in the number of observed variantsb and d) The true variants were known from bulk sequencing. 4/5 of the variants showed same sensitivity before and after. There is one variant with low sensitivity.

Tapestri Solution

Nu

mb

er o

f V

aria

nts

b). High sensitivity in most of the variants. There were 3 different FN’s that can be improved by further optimization.

Learn more about Mission Bio at our other posters at SCGPoster Session Title

P028 24th Doublets Detection in Single Cell DNA-Sequencing using Deep Learning

P031 24th Co-detection of mutations and copy number variations in thousands of single-cells using an automated platform

P034 24th Using machine learning to optimize assays for single cell targeted DNA sequencing

P093 24th Single-cell Simultaneous Detection of DNA Genotype and Protein Expression

P099 24th Error Correction in single-cell DNA sequencing: Finding rare allele for MRD clone

P109 25th A high throughput single cell workflow for paired genomic and phenotypic analysis

P112 25th A triomic single-cell high-throughput microfluidic workflow for resolution of genotype-to-phenotype modalities: parallel analysis of DNA, RNA and protein

a) Pileup of mapped reads

b) Pileup frequency

c) Normalized pileup

Reads from sequencer

Dee

p Le

arni

ng

Results on PBMC sample with known truth

Cell Supporting Variants

c)

Nu

mb

er o

f V

aria

nts

Cell supporting variants

Catalog Panels for Hematology and Solid Tumor

nonECEC

nonECEC

1 2 3 4 5 6 7 8 9 10 11-2021-30

31-4041-50

51-100

101-200

201-300

301-400

401-500

901-900

901-1019

501-600

601-700

701-800

1 2 3 4 5 6 7 8 9 10 11-2021-30

31-4041-50

51-100

101-200

201-300

301-400

401-500

501-600

601-700

701-794