equalis s - ifcinflow.com · api compliance : mpms chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2...

14
Metering Solutions Countum Group Metering Solutions Countum Group EQUALIS S Flow computer for depots Measuring systems Flow computers Accessories Flow meters Equalis S is a field batch controller designed for oil depots and terminals. It meets all the requirements for tanker trucks, railcar and ships loading and unloading operations. Custody transfer certified, Equalis S is compatible with the entire range of volumetric and mass meters used in the oil industry. Equalis S is an all-in-one electronic register. It can interface directly with most terminal automation and data management systems. Field of application • Tanker truck and rail car loading and offloading • Bio-fuels online and batch blending • Additive injection control • Delivery of heating oil to individuals • Delivery of fuels to service stations • Delivery of fuels to worksites, ships, boiler rooms Key points Compact design for easy installation Because of its single box concept, Equalis S field batch controller has a drastically reduced installation cost. Its compact design allows easy installation on tank trucks and compact assemblies. User-friendly operations Equalis S Man Machine Interface offers a direct and local access to pre-programmed functions such as meter preset, ticket printing, product selection... Multifunction and powerful associated software package Equalis S can be linked to the supervisory PC using Equaview software package. This plug and play multifunction tool allows data collection, remote control of loading operations, maintenance and configuration of Equalis S flow computer. Very open communication skills Friendly remote control of loading operations Associated with the Equaview PC based database management software, Equalis S allows a comprehensive overview and access to the key loading parameters such as loaded value, blending rate, pump operation, additive content, stop of the current delivery, driver and user identification, bill of lading printing… An optimized verification tool All the diagnosis elements of the Equalis S flow computer and the operating conditions data are continuously stored by the Equaview software during the delivery in Crystal Report format. They can easily be extracted and send to Satam engineers for diagnosis or periodic verification of the flow computer. A comprehensive visualization of loading areas Equalis S continuously send to Equaview the loading area data. The gantry box represents graphically the position and status of each loading arm. The arm box gives all requested information about the transaction such as arm name, volume, temperature, flowrate, ticket number…

Upload: hacong

Post on 20-Aug-2018

268 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

Metering Solutions

Countum Group

Metering Solutions

Countum Group

EQUALIS S

Flow computer for depots

Measuringsystems

Flowcomputers

AccessoriesFlow meters

Equalis S is a field batch controller designed for oil depots and terminals. It meets

all the requirements for tanker trucks, railcar and ships loading and unloading

operations. Custody transfer certified, Equalis S is compatible with the entire range

of volumetric and mass meters used in the oil industry.

Equalis S is an all-in-one electronic register. It can interface directly with most

terminal automation and data management systems.

Field of application

• Tanker truck and rail car loading and offloading

• Bio-fuels online and batch blending

• Additive injection control

• Delivery of heating oil to individuals

• Delivery of fuels to service stations

• Delivery of fuels to worksites, ships, boiler rooms

Key points

Compact design for easy installation

Because of its single box concept, Equalis S field batch controller

has a drastically reduced installation cost. Its compact design

allows easy installation on tank trucks and compact assemblies.

User-friendly operations

Equalis S Man Machine Interface offers a direct and local access

to pre-programmed functions such as meter preset, ticket

printing, product selection...

Multifunction and powerful associated software package

Equalis S can be linked to the supervisory PC using Equaview

software package. This plug and play multifunction tool allows

data collection, remote control of loading operations,

maintenance and configuration of Equalis S flow computer.

Very open communication skills

Friendly remote control of loading operations

Associated with the Equaview PC based database management

software, Equalis S allows a comprehensive overview and

access to the key loading parameters such as loaded value,

blending rate, pump operation, additive content, stop of the

current delivery, driver and user identification, bill of lading

printing…

An optimized verification tool

All the diagnosis elements of the Equalis S flow computer and

the operating conditions data are continuously stored by the

Equaview software during the delivery in Crystal Report format.

They can easily be extracted and send to Satam engineers for

diagnosis or periodic verification of the flow computer.

A comprehensive visualization of loading areas

Equalis S continuously send to Equaview the loading area data.

The gantry box represents graphically the position and status of

each loading arm. The arm box gives all requested information

about the transaction such as arm name, volume, temperature,

flowrate, ticket number…

Page 2: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

Technical Data - Flow computer

Model EQUALIS S

Aplication Electronic register, batch controller to be field mounted

Functions

Control of dosing valves and blending valvesAdditive injection control (can control up to 12 additives per metering line)

Management of safety devices (grounding, overfilling…)Calculation of base volume, mass and price

Secured back-up of metrological data transactions

Control of functions associated with the fuel distribution on truck

(motor, pump clutch, valve, drain valve, bottom valve, overfill probe)

Metrology Meter Inputs PD Meter, mass flow meter, ultrasonic meter, turbine meter

Temperature Inputs Pt 100 or 4-20 mA transmitter

Density input RS485 Modbus or 4-20 mA transmitter

Pressure input 4-20 mA transmitter

Base volume/mass calculation Fuels: ASTM 54B table - Ethanol, methyl ester, bio-diesel : ASTM 54C table

Lubrication oils: ASTM 54D table - LPG: ASTM API as per NF M80 17

Equipment User Interface Display : Graphic screen, 240 x 128 pixels, backlight

Volume resolution : 999999 points

Numeric keyboard, pre-programmed pushbuttons, cycle start/stop pushbutton

Enclosure Aluminum base with epoxy coating

Data storage 60 000 transactions

Associated software package Equaview for :

Data collection from Equalis batch controller, database management

Remote control and display of loading operations

Maintenance and configuration tool

Printing of ticket, delivery slip, bill of lading

Inputs/Outputs Meter inputs 1 or 2 inputs dual-pulse with flow direction

Intrinsic safety or NAMUR*

Pt100 inputs 1 or 2* inputs (4-wire Pt100)

Current inputs 1 or 2* for pressure, temperature and density measurements

Digital inputs 15 inputs (intrinsic safety) and 2* input (NAMUR)

for grounding system, arm position, overfilling system, additive volume,

vapour recovery, emergency stop

Digital outputs 10 (+10*) relays (250V, 10A)

for valve commands, pump, alarm, additive injection control

Pulse outputs 1 volume output for seal parcel delivery & additive injection control

Current input 1 for flow rate, density, temperature, control valve (in preparation)

Databus 1 port RS485 or Ethernet TCP/IP : communication with supervisory system and measurements inputs

1 port RS485 or RS232 : printerCommunication protocole : Modbus RTU

1 port USB : Data extraction

Operating conditions Ambient temperature Standard : -20 °C to +55 °C - Option : -40 °C to +55 °C

Certification for potentially explosive atmospheresATEX et IEC Ex

Zone 1 – II 2 (1) 1 G Ex d [ia Ga] ia IIB T4 Gb Ga

Protection class IP66

Power supply 100 to 240 VAC 50 à 60 Hz - 19 to 36 VDC (only for truck version)

Custody transfer approval Evaluation certificate EC/MID évaluation n° LNE-25874

Type compliance certificate OIML R117-1 n° LNE-24351

Dimensions Height x width x depth (mm) : 278 x 350 x 192 (without cable glands)

Weight : 16 kg

B071-IFC-GB-REV2-0917-Marketing SatamCréation & Impression : TACTIC IMPRESSIONS - 01 39 86 19 08

As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]

Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com

Page 3: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

Metering Solutions

Countum Group

Metering Solutions

Countum Group

Equalis S for trucks

Flow computer for on board metering

The Satam Equalis S is a powerful and versatile field batch controller designed for

aircraft refueling vehicles and tank trucks. It meets all the requirements in terms of

security and accuracy for installation fuels transport vehicles. Custody transfer

certified, Equalis S is compatible with the entire range of volumetric meters

used in this industrial sector. It can directly interface with most cab mounted data

capture systems.

Field of applications• Delivery of oil and fuel via tank truck

• Delivery of aviation fuels to aircrafts via fuel

transport vehicles

Very open communication skills

Communications features

Communication via serial link, Ethernet and USB port

Analog and binary inputs and outputs

Configurable printing of parameters and transactions

Data transfer to Host system

Large number of supported protocols

Can be directly linked to cab mounted data capture systems

Compatible with most of existing measuring devices

An optimized verification tool

Diagnosis elements and the operating data continuously

stored by the management software during the delivery.

Possibility to extract data via USB port or serial link

Remote access for periodic verification and diagnosis

User-friendly operations

Man-Machine Interface with direct and local access to

pre-programmed functions such as meter calibration,

meter selection, ticket printing, emergency stop...

On screen browsing of stored transactions

Duplication of volume or mass display

Key pointsMetrology

Weight and Measures Custody transfer approved

Approved measurements of volume, temperature and density

Calculation of base volume, mass, rate of flow

Transactions in operating volume, base volume or mass

Multipoint calibration for an optimized measurement accuracy

Possibility to connect of one or two meters to the Equalis

Transactions and data storage

High capacity of transactions storage (more then 60 000 transactions)

Complete recording of events and operating status

Secured back-up of stored data

Compact design for easy installation

Because of its simplified design, Equalis S field batch controller

has a drastically reduced installation cost. Its compact housing

allows easy installation on aircraft refuelers, tank trucks and

compact assemblies.

Comprehensive automation and control functions

Management of overfilling sensors and security devices

Direct management of additives injection

Management of engine start-up and acceleration

Seal parcel delivery compatible

Pneumatic manifold control

Management and control of defueling operation

Control of purge valves and pipeline air blasting

Side to side transfert

Measuringsystems

Flowcomputers

AccessoriesFlow meters

Page 4: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

B085-IFC-GB-REV1-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Technical Data - Flow computer

Model EQUALIS S

Aplication Electronic register, batch controller to be field mounted

Functions

Calculation of corrected volume and massSecured back-up of metrological data transactions

Management of safety devices (grounding, dead man…)Control of loading valves and blending valves

Additive injection control

Control of functions associated with the fuel distribution on truck

(motor, pump clutch, valve, drain valve, bottom valve, overfill probe)

Metrology Meter Inputs PD Meter, mass flow meter, ultrasonic meter, turbine meter

Temperature Inputs Pt 100

Density input RS485 Modbus or 4-20 mA transmitter

Pressure input 4-20 mA transmitter

Corrected volume/mass calculationCalculation of base volume at 15°C, 20°C and 30°C

Fuels : ASTM 54B & 60B tables - Ethanol, methyl ester, bio-diesel : ASTM 54C & 60C tables

Lubrication oils: ASTM 54D & 60D table - LPG: ASTM API as per NF M80 17

Equipment User interface moduleInputs: meter, temperature (Pt100), current (4-20 mA), binary

Display : graphic screen, 240 x 128 pixels, backlight, volume resolution : 999999 points

Display repeater*: graphic screen, 240 x 128 pixels, backlight, 999999 points

Keyboard: numeric, antivandalism design

Push buttons: pre-programmed, start/stop cycle

Transaction module Power supply, relays outputs, databus

Enclosures User interface module : aluminum base with epoxy coating

Transaction module (ATEX version) : aluminum

Transaction module (non ATEX version) : polycarbonate

Data storage 60 000 transactions

Associated software package Maintenance and configuration tool

Inputs/Outputs Meter inputs 1 or 2 inputs dual-pulse with flow direction

Intrinsic safety or NAMUR*

Temperature inputs 1 or 2* inputs (4-wire Pt100)

Current inputs 1 or 2* for pressure, temperature and density measurements (in preparation)

Digital inputs 15 inputs (intrinsic safety) and 2* input (NAMUR)

for grounding system, overfilling system,

additive volume, emergency stop

Digital outputs 10 (+10*) relays (250V, 10A)

for valve commands, pump, alarm, additive injection control

Pulse outputs 1 volume output for seal parcel delivery & additive injection control

Current output 1 for rate of flow

Databus 1 RS232 port : printer1 RS232 port: communication with data capture system1 RS485 or Ethernet TCP/IP port (upon request): communication with data capture system and measurements inputs1 USB port: data extration and software updatingSupported protocols : Modbus, Rubis/Saphir, IFSF (in preparation)

Operating conditions Ambient temperature Standard : -20 °C to +55 °C - Option : -40 °C to +55 °C (compact version)

Certification for potentially explosive atmospheresATEX and IEC Ex

Zone 1 – II 2 (1) 1 G

Protection class IP66

Power supply 19 to 36 VDC - 12VDC in preparation

Custody transfer approvalEvaluation certificate EC/MID

Type compliance certificate OIML R117-1

API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2

Dimensions and weight Height x width x deepth (mm) Weight

Remote version User interface module

Transactions module (ATEX version)

Transactions module (non ATEX version)

Compact version (all-in-one flow computer)

216 x 285 x 71 (without cable gland)

260 x 359 x 69 (without cable gland)

278 x350 x115 (without cable gland)

278 x350 x192 (without cable gland)

5.0 kg

5.7 kg

8.5 kg

16.0 kg

*Option

As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]

Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com

Page 5: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

Metering Solutions

Countum Group

The Satam “Master Meter” product range is dedicated to periodic calibration ofcustody transfer measuring equipment.The ZCM 17 is a working standard that can be used regularly to check and calibratemeasuring instruments or measuring systems. With minimal dimensions, it caneasily be moved to several different sites without the requirement for lifting tools.Equipped with an Equalis electronic register that ensures linearization ofmeasurements, it can be used with liquids of various viscosities without no loss ofaccuracy.

Sector of applicationOil depots

For oil product reception and loading stations for tank truck,

tank car and ships.

Hydrocarbon transportation

Distribution of fuel oil or fuel by road tanker.

Aircraft refuelling

Aircraft dispensers and aircraft fuelling tankers.

Army

Depot supplies and loading of trucks.

Transport companies

Refuelling of locomotives, trucks and public transport coaches.

Marine applications

Refuelling of ships.

Mining sites

Refuelling of trucks or site machinery.

Design of the master meterRobust construction

Positive displacement meter with moving blades.

Modular design

Available with mechanical or electronic register.

Calibration for different viscosities

Supplied with one calibration certificate

per each operating viscosity.

Key pointsCompact design

Calibration device of reduced weight and dimensions.

Possibility to move the ZCM 17 to different sites without

the requirement for lifting tools

Self powered technology

Functioning of the mechanical register version

without any power supply.

Modular design

Wide range of accessories to create your customized

calibration device.

Can be installed on a trolley as mobile calibration equipment.

Stability and accuracy of measurements

Stable and accurate volume measurement without any influence

of installation position.

Flowmeter manifold separated from measurement chamber to

eliminate any possible influence of external mechanical stresses

on measurement accuracy.

Metering Solutions

Countum Group

ZCM 17

Master meter

Measuringsystems

Flowcomputers

AccessoriesFlow meters

Page 6: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

B086-IFC-GB-REV2-09/17-Marketing SatamDesign & printing: TACTIC IMPRESSIONS - 01 39 86 19 08

Technical data - Master meter ZCM 17

Versions ZCM 17 IM ZCM 17 IE

Register

Mechanical register (VR)

Total volume with reset: 5 digits

Total volume without reset: 8 digits

Electronic register (Equalis)

Total volume: 6 digits

Secure storage of ZCM 17 calibration curves

Calculation of base volume

Volume display Operating volume Operating volume, base volume

Flowrate display Included with IDI module L/mn or m3/h Included

Calibration curve 7 flowrate values with 2 values per flowrate

One curve per operating viscosity

Calculation of base volume Manual calculation Automatic calculation

Temperature measurement* Local display Pt 100

Pressure measurement* Local display

Isolating valve* Ball valve located downstream the PD meter

Drainage equipment* Manual drainage pump with purge valve and 2 release valves

Trolley* Calibration device mounted on chassis with 4 pivoting wheels

Operating conditions Pressure 10 bar max.

Viscosity 50 cSt max.

Liquid temperature -10 °C to +80 °C

Ambient temperature Standard : - 25 °C to + 55 °C - Option : - 40 °C to + 55 °C

Contact us for higher or lower temperatures

Metrological performances Volume accuracy < 0,1% < 0,05% with linearization

Volume repeatability < 0,02%

Temperature accuracy <± 0.5°C

Calibration certificate - Linearization curve Calibration certificate according to OIML R117

Installation Electrical power supply No (self-powered device) 24 VCC or 230 VCA

ATEX certification Zone 1 ; II 2 G* : optional supply

Model ZCM 17 24 48 80 150 250 330

Application Master meter dedicated to calibration of custody transfer volume measuring equipments

Max. Operating flowrate m3/h - L/mn - USGPM 24 - 400 - 105 48 - 800 - 210 80 - 1333 - 360 150 - 2500 - 660 250 - 4166 - 1100 330 - 5500 - 1453

Min. Operating flowrate m3/h - L/mn - USGPM 2.4 - 40 - 10.5 4.8 - 80 - 21 8 - 133.3 - 36 15 - 250 - 66 25 - 416.6 - 110 33 - 550 - 145

Measured parameters Operating volume

Base volume (only for ZCM 17 IE)

Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol,

kerosene, fatty acid methyl ester oils

Connections Flanges or dry couplings*

2 x 3 m hoses*

Meter Diameter 2" 2" 3" 4" 6" 8"

PD meter ZC17-24 ZC17-48 ZC17-80 ZC17-150 ZC17-250 ZC17-330

As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]

Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com

Page 7: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

ZCE 6 horizontal metering unit is designed for truck and train tankers loading

stations in a top or bottom configuration.

ZCE 6 space-saving configuration enables easy installation in smaller facilities

and in compact pipeline network.

Sectors of application

• Tanker trucks and railcars loading applications

• Preparation of bio-fuels by means of online

or batch blending

• Measurement of white products and bio-fuels

High reliability measuring system

Ready-made technology

ZCE 6 horizontal vertical measuring systems are completely

assembled, wired and tested in the production facility in order

to ensure a maximum reliability.

Measurement stability and accuracy

Measurement accuracy guaranteed over a period of many years

without any deviation in the calibration curve.

Modular design

Extensive line of accessories to create customized

measurement applications.

Key points

Low installation costs

Complete and ready-to-install measuring unit

including strainer, air eliminator, PD meter, valve and register.

Low maintenance costs

Simple and robust construction with minimal moving parts

Interchangeable mechanical components.

Space-saving installation

Compact metering unit for installation in smaller areas

and in vertical pipeline networks.

A safe and easy-to-use technology

Automatic gas elimination system to start loading operation

with empty pipe.

Filtering system with automatic clogging detection (option).

Communication

Direct communication with supervisory system with the

electronic register version.

Metering Solutions

Countum Group

ZCE 6

Metering system for truck and railcar loading

Measuringsystems

Flowcomputers

AccessoriesFlow meters

Page 8: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

B073-IFC-GB-REV0-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Technical data - Horizontal metering system

B A

C C1

D1D

Measuring system ZCE 6-80 ZCE 6-150 ZCE 6-250Maximum flow rate m3/h - L/mn - USGPM 80 - 1333 - 360 150 - 2500 - 660 250 - 4166 -1100

Application Tanker truck and rail car loading application, product transfert

Measured parameters Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature*(* : only for electronic register version, ** : option for mechanical register version)

Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene,

fatty acid methyl ester, oils

Equipment Strainer - Gas elimination device EC 31 EC 32 EC 39

50 to 450 μ filtering (270 to 40 Mesh) depending on the liquid

Gas release controlled by float and differential valve

PD meter ZC 17-80 ZC 17-150 ZC 17-250

Temperature measurement 4-wire Pt100 (option for electronic calculator version)

Multi-function valve Small and large flow, authorisation, flow limitation

XAD 37 DN3’’ XAD 36 DN4’’ XAD DN6’’

electrical control

mechanical control -

Flow register Mechanical register model VR with pre set*, printer*, pulser* (* : option)

or Equalis flow computer with display, secure archiving of transactions

Operating conditions Pressure 10 bar max.

Viscosity 20 cSt max. – Contact us about higher viscosities

Liquid temperature -10 to +80 °C

Ambient temperature Standard: -25 to +55 °C ; Option -40 to +55 °C

Ask us about higher or lower temperatures

Metrological performances Accuracy ≤ ±0.15 % - Option ≤ ±0.1 % - for measurement range of 10 : 1

Repeatability ≤ ±0.02 %

Temperature accuracy ≤ 0.5 °C

Installation ATEX certification Zone 1 ; II 2 G

Custody transfer approval MID - CE Evaluation Certificate n° LNE-11052 (ZC17)

Type compliance certificate OIML R117 n°LNE-24351 (ZC17)

Dimensions (mm) and weight ZCE 6-80 ZCE 6-150 ZCE 6-250Distance between flanges (A) 970 1081 1456

Width (B) 456 524 640

Height (C) 875 875 -

Height (C1) - - 1110

D 459 459 -

D1 - - 700

Weight (kg) 190 230 405

As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]

Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com

Page 9: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

Metering Solutions

Countum Group

EMS 24 - EMS 48 are compact metering units designed to measure pressurized

hydrocarbons on road tankers, especially fuel delivery tankers. They can be fitted with

mechanical register or Equalis electronic flow computer for a secure archiving of the

transactions and for a control of all the actions linked to delivery operations.

Sector of application

• On-board measurement on tank trucks

• Preparation of biofuels by means of on-line

batch blending

• Measurement of white products and of biofuels

High reliability measuring system

A compact metering unit

Significant reduction in the dimensions and weight of the unit.

Simplified installation on the fuel delivery tanker.

A rugged and reliable metering technology

PD meter with moving blades.

Excellent long term stability.

Integrated strainer and air eliminator.

Measurement accuracy independent of liquid viscosity.

High flexibility of installation

Fully assembled and tested in production facility.

Key points

Low installation cost

Complete and ready to install measuring unit including strainer,

air eliminator, PD meter, valve and register.

Self powered technology

No need for power supply with mechanical register version.

Low maintenance costs

Simple and robust construction with minimal moving mechanical

parts.

Stability of measurements

Measurement accuracy guaranteed over a period of many years

without drift of the calibration curve.

Multi purpose operation

The flow computer version controls the automatic system

linked to deliveries such as control of bottom valves, pump

engagement.

Versatile communication with flow computer version

Secure archiving of metrology data and transactions.

Transmission of transactions to data processing system

via data bus or memory stick.

Metering Solutions

Countum Group

EMS 24 & EMS 48

On board metering unit

Measuringsystems

Flowcomputers

AccessoriesFlow meters

Page 10: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

B028-IFC-GB-REV0-0917-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Technical data - On board metering system

Dimensions (mm) and weight EMS 24 EMS 48

Length (A) 785 863

Width (B) 461 461

Height (C) 662 662

Weight (kg) 56 62

Applications On-board metering system for tank truck, truck loading application, in-line blending

Measured parameters Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature* (* : only for electro-

nic register version) (** : option for mechanical register version)

Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene,

Fatty acid methyl ester oils

Equipment Strainer & gas elimination device Model EC 42 / FS 24

Horizontal stainless steel 450 µm basket filter (diesel fuel) or 200 µm (petrol)

Aluminum housing with non return valve

Gas release controlled by float and differential valve

Temperature measurement 4-wire Pt 100 (option for electronic calculator version)

Multifunction valve XAD 39 available in mechanical or electrical version

XAD 54 pneumatic version

Low and high flow rate, authorization, restriction of flow rate

3-way valve (option) Distribution to hose on reel or to short hose

Register Mechanical register model VR , preset*, printer*, pulser*, (* : option)

or Electronic register model Equalis with display, secure archiving of transactions

Operating conditions Pressure 8 bar max. -10 bar upon request

Viscosity 20cSt max. – Consult us about higher viscosities

Liquid temperature -10 to + 80 °C

Ambient temperature Standard -25 to + 55 °C ; Option -40 to + 55 °C

Contact us about higher or lower temperatures

Metrological performances Volume accuracy ≤ ±0.15 % - Option ≤ ±0.1 % - for measuring range 10 : 1

Volume repeatability ≤ ±0.02 %

Temperature accuracy ≤ 0.5 °C

Installation ATEX certification Zone 1 ; II 2 G

Custody transfer approval MID CE type approval n°LNE11123

Type Compliance certificate OIML R117 n°LNE-24351

Measuring system EMS 24 EMS 48

Maximum flow rate m3/h - L/mn - USGPM 24 - 400 - 105 48 - 800 - 210

PD meter ZC 17-24 ZC 17-48

AB

C

210

As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]

Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com

Page 11: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

Metering Solutions

Countum Group

The SATAM Positive Displacement Meter (PD meter) is a system with freely-moving blades used to measure petroleum products such as fuels, bio-fuels and refinedliquid hydrocarbons and non corrosive chemicals.Its simple design with only two pairs of blades and one moving rotor makes itexceptionally robust and allows the user to make significant savings onmaintenance costs.

Sectors of applicationOil depots

For oil product reception and loading stations for tank truck,

tank car and ships.

Hydrocarbon transportation

Distribution of fuel oil or fuel by road tanker.

Aircraft refuelling

Aircraft dispensers and aircraft fuelling tankers.

Army

Depot supplies and loading of trucks.

Transport companies

Refuelling of locomotives, trucks and public transport coaches.

Marine applications

Refuelling of ships.

Mining sites

Refuelling of trucks or site machinery.

Operating principleThe product enters the measuring chamber following the

direction of the arrow. The rotor and blades assembly (1-2) is

set in motion by the pressure of the liquid on blades. A certain

amount of liquid (3) is held between 2 blades and then directed

to the discharge manifold. The volume of liquid measured at

each rotation is therefore equal to 4 times the measured

quantity (3). The smooth curves the meter pieces provide a

steady, non-fluctuating flow resulting in low head loss.

Key pointsReduced pressure loss

0.3 to 0.5 bar at maximum flow rate.

Low maintenance costs

Simple and robust design with mechanical components

interchangeable between the different models.

Stability of measurements

Accuracy of measurement guaranteed over a period of many

years without any drift in the calibration curve.

Modular design

Wide range of accessories for performing customized

measurement applications.

Robust construction

Flowmeter manifold is separated from measurement chamber

to eliminate any possible influence of external mechanical

stresses on measurement accuracy.

Few moving parts.

Metering Solutions

Countum Group

ZC 17

Positive Displacement Meter

1

3

2

Measuringsystems

Flowcomputers

AccessoriesFlow meters

Page 12: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

B037-IFC-GB-REV3-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]

Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FRANCEPhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com

Technical data - PD meter ZC 17Model ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330

Application Custody transfer metering of liquid hydrocarbons

Max. Flowrate (m3/h - L/mn - USGPM) 12-200-53 24-400-105 48-800-210 80-1333-360 150-2500-660 250-4166-1100 330-5500-1453

Min. Flowrate (m3/h - L/mn - USGPM) 1.2-20-5.3 2.4-40-10.5 4.8-80-21 8-133-36 15-250-66 25-416-110 33-550-145

Connections DN 2’’ 2’’ 2’’ 3’’ 4’’ 6’’ 8’’

Flanges (standard) Standard Satam ASA 150 RF

Flanges (option) ASA 150 RF DIN28463TW1 DIN28463TW3

Other flanges upon request

Materials Manifold Aluminum Steel or ductile iron or

aluminum

Steel or ductile iron

Casing Aluminum Aluminum or

Ni resist Iron

Ductile iron or Ni resist iron

Front and back cover Carbon steel with protective coating

Rotor - Blades - Gaskets Aluminum - Graphite - Viton (option nitrile)

Operating conditions Max. pressure (operation) 10 bar -150 PSI

Max. pressure (EC/MID certificate) 8 bar6 bar (gasoline, kerosene)

8 bar (diesel oil, ethanol)10 bar

Max. viscosity MID : 20mm²/s (cSt) - Operation : 800 mm²/s (cSt) MID : 57mm²/s

Liquid temperature -10 °C to +55 °C

Ambient temperature Standard : -20 °C to +55 °C - Option : -40 °C to +55 °C

Consult us for higher or lower temperatures

Pressure drop at max flowrate, 3,7 mm²/s (cSt) 0.45 0.35

Internal construction Cyclic volume (L - USG) 0,33-0.08 0,40-0.10 0,80-0.21 2,27-0.6 4,54-1.2 6,82-1.8 9.09-2.4

Metrological performances Accuracy < 0,15 % / Option < 0,1 % For 10 : 1 measuring range

Repeatability < 0,02 %

Installation ATEX certification Zone 1 - II 2 G

Custody transfer approval EC-MID Evaluation Certificate N° LNE-11052

Type Compliance Certificate OIML R117 n°LNE-24351

Dimensions (mm) and weight ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330

Distance between flanges (A) 180 180 180 356 432 400 400

Width (B) 290 290 290 356 432 400 400

Depth (C) with mechanical register

with pulser

220

186

220

186

246

266

365

272

492

399

620

526

746

653

Height (D) with mechanical register

with pulser

368

260

406

260

406

260

502

502

521

521

568

568

625

625

Weight (kg) with mechanical register 18 22 26 75 95 155 200

Flanges positions

Flanges ASA150 with mechanical register PH1, PH2PH1, PH2, PV1, PV2, PV3, PV4

Flanges ASA150 with pulser PH1, PH2, PV1, PV2, PV3, PV4

Flanges TW with mechanical register or pulser - - -PH1, PH2,

PV1 to PV10

PH1, PH2,

PV1 to PV6- -

ZC 17- 80, 150, 250 & 330

ZC 17- 12, 24 & 48

Page 13: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

Metering Solutions

Countum Group

Metering Solutions

Countum Group

ZCE 5

Measuringsystems

Flowcomputers

AccessoriesFlow meters

ZCE 5 vertical metering unit is designed for truck and train tankers loading stations

in a top or bottom loading configuration.

ZCE5 space-saving configuration enables easy installation in smaller facilities and

in compact pipeline network.

Sectors of application

• Tanker trucks and railcars loading applications

• Preparation of bio-fuels by means of online or batch

blending

• Measurement of white products and bio-fuels

• Additive injection control

High reliability measuring system

Ready-made technology

ZCE 5 vertical measuring units are completely assembled,

wired and tested in the production facility in order to ensure

a maximum reliability.

Measurement stability and accuracy

Measurement accuracy guaranteed over a period of many

years without any deviation in the calibration curve.

Modular design

Extensive line of accessories to create customized

measurement applications.

Key points

Low installation costs

Complete and ready-to-install compact measuring unit

including strainer, air eliminator, PD meter, valve

and register.

Low maintenance costs

Simple and robust construction with minimal moving parts.

Interchangeable mechanical components.

Space-saving installation

Compact metering unit for installation in smaller areas

and in vertical pipeline networks.

A safe and easy-to-use technology

Automatic gas elimination system to start loading

operation with empty pipe.

Filtering system with automatic clogging detection.

Communication

Direct communication with supervisory system.

Vertical measuring unit for truck and railcar loading

Page 14: EQUALIS S - ifcinflow.com · API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2 Dimensions and weight Height x width x deepth (mm) Weight Remote version User interface

B026-IFC-GB-REV0-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08

Technical data - Vertical measuring unit for loading

Model ZCE 5-80 ZCE 5-150

Maximum flow rate m3/h - L/mn - USGPM 80 - 1333 - 360 150 - 2500 - 660

Connections Flanges 3'' ASA 150 RF 4'' ASA150 RF

Description Compact vertical metering unit

Measured parameters Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature*

(* : only for electronic register version, ** : option for mechanical register version)

Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol,

kerosene, fatty acid methyl ester, oils

Equipment Strainer - Gas elimination device Model EC 29

50 to 450 filtering (270 to 40 Mesh) depending on the liquid

Gas release controlled by float and differential valve

PD meter ZC 17-80 ZC 17-150

Temperature measurement 4-wire Pt100 (option for electronic calculator version)

Multi-function valve XAD 37 XAD 36

Small and large flow authorisation, flow limitation

Electrical control or mechanical control

Flow register Mechanical register model VR with pre set*, printer*, pulser*

or Equalis electronic register with display, secure archiving of transactions

Operating conditions Pressure 10 bar max.

Viscosity 20cSt max. – Contact us about higher viscosities

Liquid temperature -10 à +80 °C

Ambient temperature Standard -25 to +55 °C ; Option -40 to +55 °C

Contact us about higher or lower temperatures

Metrological performance Volume accuracy ≤±0.15% - Option ≤±0.1% - for measurement range of 10 : 1

Volume repeatability ≤ ±0.02 %

Temperature accuracy ≤ 0.5 °C

Installation ATEX certification Zone 1 - II 2 G

Custody transfer approval MID - CE type approval n° LNE 6184

Type compliance certificate OIML R117 n°LNE-24351

Dimensions and weight net weight without extension 200 kg 240 kg

Net weight with extension 235 kg 275 kg

As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.

Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]

Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com