Equalis S is a field batch controller designed for oil depots and terminals. It meets
all the requirements for tanker trucks, railcar and ships loading and unloading
operations. Custody transfer certified, Equalis S is compatible with the entire range
of volumetric and mass meters used in the oil industry.
Equalis S is an all-in-one electronic register. It can interface directly with most
terminal automation and data management systems.
Field of application
• Tanker truck and rail car loading and offloading
• Bio-fuels online and batch blending
• Additive injection control
• Delivery of heating oil to individuals
• Delivery of fuels to service stations
• Delivery of fuels to worksites, ships, boiler rooms
Key points
Compact design for easy installation
Because of its single box concept, Equalis S field batch controller
has a drastically reduced installation cost. Its compact design
allows easy installation on tank trucks and compact assemblies.
User-friendly operations
Equalis S Man Machine Interface offers a direct and local access
to pre-programmed functions such as meter preset, ticket
printing, product selection...
Multifunction and powerful associated software package
Equalis S can be linked to the supervisory PC using Equaview
software package. This plug and play multifunction tool allows
data collection, remote control of loading operations,
maintenance and configuration of Equalis S flow computer.
Very open communication skills
Friendly remote control of loading operations
Associated with the Equaview PC based database management
software, Equalis S allows a comprehensive overview and
access to the key loading parameters such as loaded value,
blending rate, pump operation, additive content, stop of the
current delivery, driver and user identification, bill of lading
printing…
An optimized verification tool
All the diagnosis elements of the Equalis S flow computer and
the operating conditions data are continuously stored by the
Equaview software during the delivery in Crystal Report format.
They can easily be extracted and send to Satam engineers for
diagnosis or periodic verification of the flow computer.
A comprehensive visualization of loading areas
Equalis S continuously send to Equaview the loading area data.
The gantry box represents graphically the position and status of
each loading arm. The arm box gives all requested information
about the transaction such as arm name, volume, temperature,
flowrate, ticket number…
Technical Data - Flow computer
Model EQUALIS S
Aplication Electronic register, batch controller to be field mounted
Functions
Control of dosing valves and blending valvesAdditive injection control (can control up to 12 additives per metering line)
Management of safety devices (grounding, overfilling…)Calculation of base volume, mass and price
Secured back-up of metrological data transactions
Control of functions associated with the fuel distribution on truck
(motor, pump clutch, valve, drain valve, bottom valve, overfill probe)
Metrology Meter Inputs PD Meter, mass flow meter, ultrasonic meter, turbine meter
Temperature Inputs Pt 100 or 4-20 mA transmitter
Density input RS485 Modbus or 4-20 mA transmitter
Pressure input 4-20 mA transmitter
Base volume/mass calculation Fuels: ASTM 54B table - Ethanol, methyl ester, bio-diesel : ASTM 54C table
Lubrication oils: ASTM 54D table - LPG: ASTM API as per NF M80 17
Equipment User Interface Display : Graphic screen, 240 x 128 pixels, backlight
Volume resolution : 999999 points
Numeric keyboard, pre-programmed pushbuttons, cycle start/stop pushbutton
Enclosure Aluminum base with epoxy coating
Data storage 60 000 transactions
Associated software package Equaview for :
Data collection from Equalis batch controller, database management
Remote control and display of loading operations
Maintenance and configuration tool
Printing of ticket, delivery slip, bill of lading
Inputs/Outputs Meter inputs 1 or 2 inputs dual-pulse with flow direction
Intrinsic safety or NAMUR*
Pt100 inputs 1 or 2* inputs (4-wire Pt100)
Current inputs 1 or 2* for pressure, temperature and density measurements
Digital inputs 15 inputs (intrinsic safety) and 2* input (NAMUR)
for grounding system, arm position, overfilling system, additive volume,
vapour recovery, emergency stop
Digital outputs 10 (+10*) relays (250V, 10A)
for valve commands, pump, alarm, additive injection control
Pulse outputs 1 volume output for seal parcel delivery & additive injection control
Current input 1 for flow rate, density, temperature, control valve (in preparation)
Databus 1 port RS485 or Ethernet TCP/IP : communication with supervisory system and measurements inputs
1 port RS485 or RS232 : printerCommunication protocole : Modbus RTU
1 port USB : Data extraction
Operating conditions Ambient temperature Standard : -20 °C to +55 °C - Option : -40 °C to +55 °C
Certification for potentially explosive atmospheresATEX et IEC Ex
Zone 1 – II 2 (1) 1 G Ex d [ia Ga] ia IIB T4 Gb Ga
Protection class IP66
Power supply 100 to 240 VAC 50 à 60 Hz - 19 to 36 VDC (only for truck version)
Custody transfer approval Evaluation certificate EC/MID évaluation n° LNE-25874
Type compliance certificate OIML R117-1 n° LNE-24351
Dimensions Height x width x depth (mm) : 278 x 350 x 192 (without cable glands)
Weight : 16 kg
B071-IFC-GB-REV2-0917-Marketing SatamCréation & Impression : TACTIC IMPRESSIONS - 01 39 86 19 08
As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.
Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]
Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com
Metering Solutions
Countum Group
Metering Solutions
Countum Group
Equalis S for trucks
Flow computer for on board metering
The Satam Equalis S is a powerful and versatile field batch controller designed for
aircraft refueling vehicles and tank trucks. It meets all the requirements in terms of
security and accuracy for installation fuels transport vehicles. Custody transfer
certified, Equalis S is compatible with the entire range of volumetric meters
used in this industrial sector. It can directly interface with most cab mounted data
capture systems.
Field of applications• Delivery of oil and fuel via tank truck
• Delivery of aviation fuels to aircrafts via fuel
transport vehicles
Very open communication skills
Communications features
Communication via serial link, Ethernet and USB port
Analog and binary inputs and outputs
Configurable printing of parameters and transactions
Data transfer to Host system
Large number of supported protocols
Can be directly linked to cab mounted data capture systems
Compatible with most of existing measuring devices
An optimized verification tool
Diagnosis elements and the operating data continuously
stored by the management software during the delivery.
Possibility to extract data via USB port or serial link
Remote access for periodic verification and diagnosis
User-friendly operations
Man-Machine Interface with direct and local access to
pre-programmed functions such as meter calibration,
meter selection, ticket printing, emergency stop...
On screen browsing of stored transactions
Duplication of volume or mass display
Key pointsMetrology
Weight and Measures Custody transfer approved
Approved measurements of volume, temperature and density
Calculation of base volume, mass, rate of flow
Transactions in operating volume, base volume or mass
Multipoint calibration for an optimized measurement accuracy
Possibility to connect of one or two meters to the Equalis
Transactions and data storage
High capacity of transactions storage (more then 60 000 transactions)
Complete recording of events and operating status
Secured back-up of stored data
Compact design for easy installation
Because of its simplified design, Equalis S field batch controller
has a drastically reduced installation cost. Its compact housing
allows easy installation on aircraft refuelers, tank trucks and
compact assemblies.
Comprehensive automation and control functions
Management of overfilling sensors and security devices
Direct management of additives injection
Management of engine start-up and acceleration
Seal parcel delivery compatible
Pneumatic manifold control
Management and control of defueling operation
Control of purge valves and pipeline air blasting
Side to side transfert
Measuringsystems
Flowcomputers
AccessoriesFlow meters
B085-IFC-GB-REV1-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08
Technical Data - Flow computer
Model EQUALIS S
Aplication Electronic register, batch controller to be field mounted
Functions
Calculation of corrected volume and massSecured back-up of metrological data transactions
Management of safety devices (grounding, dead man…)Control of loading valves and blending valves
Additive injection control
Control of functions associated with the fuel distribution on truck
(motor, pump clutch, valve, drain valve, bottom valve, overfill probe)
Metrology Meter Inputs PD Meter, mass flow meter, ultrasonic meter, turbine meter
Temperature Inputs Pt 100
Density input RS485 Modbus or 4-20 mA transmitter
Pressure input 4-20 mA transmitter
Corrected volume/mass calculationCalculation of base volume at 15°C, 20°C and 30°C
Fuels : ASTM 54B & 60B tables - Ethanol, methyl ester, bio-diesel : ASTM 54C & 60C tables
Lubrication oils: ASTM 54D & 60D table - LPG: ASTM API as per NF M80 17
Equipment User interface moduleInputs: meter, temperature (Pt100), current (4-20 mA), binary
Display : graphic screen, 240 x 128 pixels, backlight, volume resolution : 999999 points
Display repeater*: graphic screen, 240 x 128 pixels, backlight, 999999 points
Keyboard: numeric, antivandalism design
Push buttons: pre-programmed, start/stop cycle
Transaction module Power supply, relays outputs, databus
Enclosures User interface module : aluminum base with epoxy coating
Transaction module (ATEX version) : aluminum
Transaction module (non ATEX version) : polycarbonate
Data storage 60 000 transactions
Associated software package Maintenance and configuration tool
Inputs/Outputs Meter inputs 1 or 2 inputs dual-pulse with flow direction
Intrinsic safety or NAMUR*
Temperature inputs 1 or 2* inputs (4-wire Pt100)
Current inputs 1 or 2* for pressure, temperature and density measurements (in preparation)
Digital inputs 15 inputs (intrinsic safety) and 2* input (NAMUR)
for grounding system, overfilling system,
additive volume, emergency stop
Digital outputs 10 (+10*) relays (250V, 10A)
for valve commands, pump, alarm, additive injection control
Pulse outputs 1 volume output for seal parcel delivery & additive injection control
Current output 1 for rate of flow
Databus 1 RS232 port : printer1 RS232 port: communication with data capture system1 RS485 or Ethernet TCP/IP port (upon request): communication with data capture system and measurements inputs1 USB port: data extration and software updatingSupported protocols : Modbus, Rubis/Saphir, IFSF (in preparation)
Operating conditions Ambient temperature Standard : -20 °C to +55 °C - Option : -40 °C to +55 °C (compact version)
Certification for potentially explosive atmospheresATEX and IEC Ex
Zone 1 – II 2 (1) 1 G
Protection class IP66
Power supply 19 to 36 VDC - 12VDC in preparation
Custody transfer approvalEvaluation certificate EC/MID
Type compliance certificate OIML R117-1
API compliance : MPMS Chapters 4-1, 4-4, 5-1, 5-2, 5-4, 7, 11-1, 12-2
Dimensions and weight Height x width x deepth (mm) Weight
Remote version User interface module
Transactions module (ATEX version)
Transactions module (non ATEX version)
Compact version (all-in-one flow computer)
216 x 285 x 71 (without cable gland)
260 x 359 x 69 (without cable gland)
278 x350 x115 (without cable gland)
278 x350 x192 (without cable gland)
5.0 kg
5.7 kg
8.5 kg
16.0 kg
*Option
As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.
Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]
Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com
Metering Solutions
Countum Group
The Satam “Master Meter” product range is dedicated to periodic calibration ofcustody transfer measuring equipment.The ZCM 17 is a working standard that can be used regularly to check and calibratemeasuring instruments or measuring systems. With minimal dimensions, it caneasily be moved to several different sites without the requirement for lifting tools.Equipped with an Equalis electronic register that ensures linearization ofmeasurements, it can be used with liquids of various viscosities without no loss ofaccuracy.
Sector of applicationOil depots
For oil product reception and loading stations for tank truck,
tank car and ships.
Hydrocarbon transportation
Distribution of fuel oil or fuel by road tanker.
Aircraft refuelling
Aircraft dispensers and aircraft fuelling tankers.
Army
Depot supplies and loading of trucks.
Transport companies
Refuelling of locomotives, trucks and public transport coaches.
Marine applications
Refuelling of ships.
Mining sites
Refuelling of trucks or site machinery.
Design of the master meterRobust construction
Positive displacement meter with moving blades.
Modular design
Available with mechanical or electronic register.
Calibration for different viscosities
Supplied with one calibration certificate
per each operating viscosity.
Key pointsCompact design
Calibration device of reduced weight and dimensions.
Possibility to move the ZCM 17 to different sites without
the requirement for lifting tools
Self powered technology
Functioning of the mechanical register version
without any power supply.
Modular design
Wide range of accessories to create your customized
calibration device.
Can be installed on a trolley as mobile calibration equipment.
Stability and accuracy of measurements
Stable and accurate volume measurement without any influence
of installation position.
Flowmeter manifold separated from measurement chamber to
eliminate any possible influence of external mechanical stresses
on measurement accuracy.
Metering Solutions
Countum Group
ZCM 17
Master meter
Measuringsystems
Flowcomputers
AccessoriesFlow meters
B086-IFC-GB-REV2-09/17-Marketing SatamDesign & printing: TACTIC IMPRESSIONS - 01 39 86 19 08
Technical data - Master meter ZCM 17
Versions ZCM 17 IM ZCM 17 IE
Register
Mechanical register (VR)
Total volume with reset: 5 digits
Total volume without reset: 8 digits
Electronic register (Equalis)
Total volume: 6 digits
Secure storage of ZCM 17 calibration curves
Calculation of base volume
Volume display Operating volume Operating volume, base volume
Flowrate display Included with IDI module L/mn or m3/h Included
Calibration curve 7 flowrate values with 2 values per flowrate
One curve per operating viscosity
Calculation of base volume Manual calculation Automatic calculation
Temperature measurement* Local display Pt 100
Pressure measurement* Local display
Isolating valve* Ball valve located downstream the PD meter
Drainage equipment* Manual drainage pump with purge valve and 2 release valves
Trolley* Calibration device mounted on chassis with 4 pivoting wheels
Operating conditions Pressure 10 bar max.
Viscosity 50 cSt max.
Liquid temperature -10 °C to +80 °C
Ambient temperature Standard : - 25 °C to + 55 °C - Option : - 40 °C to + 55 °C
Contact us for higher or lower temperatures
Metrological performances Volume accuracy < 0,1% < 0,05% with linearization
Volume repeatability < 0,02%
Temperature accuracy <± 0.5°C
Calibration certificate - Linearization curve Calibration certificate according to OIML R117
Installation Electrical power supply No (self-powered device) 24 VCC or 230 VCA
ATEX certification Zone 1 ; II 2 G* : optional supply
Model ZCM 17 24 48 80 150 250 330
Application Master meter dedicated to calibration of custody transfer volume measuring equipments
Max. Operating flowrate m3/h - L/mn - USGPM 24 - 400 - 105 48 - 800 - 210 80 - 1333 - 360 150 - 2500 - 660 250 - 4166 - 1100 330 - 5500 - 1453
Min. Operating flowrate m3/h - L/mn - USGPM 2.4 - 40 - 10.5 4.8 - 80 - 21 8 - 133.3 - 36 15 - 250 - 66 25 - 416.6 - 110 33 - 550 - 145
Measured parameters Operating volume
Base volume (only for ZCM 17 IE)
Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol,
kerosene, fatty acid methyl ester oils
Connections Flanges or dry couplings*
2 x 3 m hoses*
Meter Diameter 2" 2" 3" 4" 6" 8"
PD meter ZC17-24 ZC17-48 ZC17-80 ZC17-150 ZC17-250 ZC17-330
As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.
Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]
Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com
ZCE 6 horizontal metering unit is designed for truck and train tankers loading
stations in a top or bottom configuration.
ZCE 6 space-saving configuration enables easy installation in smaller facilities
and in compact pipeline network.
Sectors of application
• Tanker trucks and railcars loading applications
• Preparation of bio-fuels by means of online
or batch blending
• Measurement of white products and bio-fuels
High reliability measuring system
Ready-made technology
ZCE 6 horizontal vertical measuring systems are completely
assembled, wired and tested in the production facility in order
to ensure a maximum reliability.
Measurement stability and accuracy
Measurement accuracy guaranteed over a period of many years
without any deviation in the calibration curve.
Modular design
Extensive line of accessories to create customized
measurement applications.
Key points
Low installation costs
Complete and ready-to-install measuring unit
including strainer, air eliminator, PD meter, valve and register.
Low maintenance costs
Simple and robust construction with minimal moving parts
Interchangeable mechanical components.
Space-saving installation
Compact metering unit for installation in smaller areas
and in vertical pipeline networks.
A safe and easy-to-use technology
Automatic gas elimination system to start loading operation
with empty pipe.
Filtering system with automatic clogging detection (option).
Communication
Direct communication with supervisory system with the
electronic register version.
Metering Solutions
Countum Group
ZCE 6
Metering system for truck and railcar loading
Measuringsystems
Flowcomputers
AccessoriesFlow meters
B073-IFC-GB-REV0-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08
Technical data - Horizontal metering system
B A
C C1
D1D
Measuring system ZCE 6-80 ZCE 6-150 ZCE 6-250Maximum flow rate m3/h - L/mn - USGPM 80 - 1333 - 360 150 - 2500 - 660 250 - 4166 -1100
Application Tanker truck and rail car loading application, product transfert
Measured parameters Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature*(* : only for electronic register version, ** : option for mechanical register version)
Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene,
fatty acid methyl ester, oils
Equipment Strainer - Gas elimination device EC 31 EC 32 EC 39
50 to 450 μ filtering (270 to 40 Mesh) depending on the liquid
Gas release controlled by float and differential valve
PD meter ZC 17-80 ZC 17-150 ZC 17-250
Temperature measurement 4-wire Pt100 (option for electronic calculator version)
Multi-function valve Small and large flow, authorisation, flow limitation
XAD 37 DN3’’ XAD 36 DN4’’ XAD DN6’’
electrical control
mechanical control -
Flow register Mechanical register model VR with pre set*, printer*, pulser* (* : option)
or Equalis flow computer with display, secure archiving of transactions
Operating conditions Pressure 10 bar max.
Viscosity 20 cSt max. – Contact us about higher viscosities
Liquid temperature -10 to +80 °C
Ambient temperature Standard: -25 to +55 °C ; Option -40 to +55 °C
Ask us about higher or lower temperatures
Metrological performances Accuracy ≤ ±0.15 % - Option ≤ ±0.1 % - for measurement range of 10 : 1
Repeatability ≤ ±0.02 %
Temperature accuracy ≤ 0.5 °C
Installation ATEX certification Zone 1 ; II 2 G
Custody transfer approval MID - CE Evaluation Certificate n° LNE-11052 (ZC17)
Type compliance certificate OIML R117 n°LNE-24351 (ZC17)
Dimensions (mm) and weight ZCE 6-80 ZCE 6-150 ZCE 6-250Distance between flanges (A) 970 1081 1456
Width (B) 456 524 640
Height (C) 875 875 -
Height (C1) - - 1110
D 459 459 -
D1 - - 700
Weight (kg) 190 230 405
As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.
Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]
Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com
Metering Solutions
Countum Group
EMS 24 - EMS 48 are compact metering units designed to measure pressurized
hydrocarbons on road tankers, especially fuel delivery tankers. They can be fitted with
mechanical register or Equalis electronic flow computer for a secure archiving of the
transactions and for a control of all the actions linked to delivery operations.
Sector of application
• On-board measurement on tank trucks
• Preparation of biofuels by means of on-line
batch blending
• Measurement of white products and of biofuels
High reliability measuring system
A compact metering unit
Significant reduction in the dimensions and weight of the unit.
Simplified installation on the fuel delivery tanker.
A rugged and reliable metering technology
PD meter with moving blades.
Excellent long term stability.
Integrated strainer and air eliminator.
Measurement accuracy independent of liquid viscosity.
High flexibility of installation
Fully assembled and tested in production facility.
Key points
Low installation cost
Complete and ready to install measuring unit including strainer,
air eliminator, PD meter, valve and register.
Self powered technology
No need for power supply with mechanical register version.
Low maintenance costs
Simple and robust construction with minimal moving mechanical
parts.
Stability of measurements
Measurement accuracy guaranteed over a period of many years
without drift of the calibration curve.
Multi purpose operation
The flow computer version controls the automatic system
linked to deliveries such as control of bottom valves, pump
engagement.
Versatile communication with flow computer version
Secure archiving of metrology data and transactions.
Transmission of transactions to data processing system
via data bus or memory stick.
Metering Solutions
Countum Group
EMS 24 & EMS 48
On board metering unit
Measuringsystems
Flowcomputers
AccessoriesFlow meters
B028-IFC-GB-REV0-0917-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08
Technical data - On board metering system
Dimensions (mm) and weight EMS 24 EMS 48
Length (A) 785 863
Width (B) 461 461
Height (C) 662 662
Weight (kg) 56 62
Applications On-board metering system for tank truck, truck loading application, in-line blending
Measured parameters Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature* (* : only for electro-
nic register version) (** : option for mechanical register version)
Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene,
Fatty acid methyl ester oils
Equipment Strainer & gas elimination device Model EC 42 / FS 24
Horizontal stainless steel 450 µm basket filter (diesel fuel) or 200 µm (petrol)
Aluminum housing with non return valve
Gas release controlled by float and differential valve
Temperature measurement 4-wire Pt 100 (option for electronic calculator version)
Multifunction valve XAD 39 available in mechanical or electrical version
XAD 54 pneumatic version
Low and high flow rate, authorization, restriction of flow rate
3-way valve (option) Distribution to hose on reel or to short hose
Register Mechanical register model VR , preset*, printer*, pulser*, (* : option)
or Electronic register model Equalis with display, secure archiving of transactions
Operating conditions Pressure 8 bar max. -10 bar upon request
Viscosity 20cSt max. – Consult us about higher viscosities
Liquid temperature -10 to + 80 °C
Ambient temperature Standard -25 to + 55 °C ; Option -40 to + 55 °C
Contact us about higher or lower temperatures
Metrological performances Volume accuracy ≤ ±0.15 % - Option ≤ ±0.1 % - for measuring range 10 : 1
Volume repeatability ≤ ±0.02 %
Temperature accuracy ≤ 0.5 °C
Installation ATEX certification Zone 1 ; II 2 G
Custody transfer approval MID CE type approval n°LNE11123
Type Compliance certificate OIML R117 n°LNE-24351
Measuring system EMS 24 EMS 48
Maximum flow rate m3/h - L/mn - USGPM 24 - 400 - 105 48 - 800 - 210
PD meter ZC 17-24 ZC 17-48
AB
C
210
As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.
Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]
Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FrancePhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com
Metering Solutions
Countum Group
The SATAM Positive Displacement Meter (PD meter) is a system with freely-moving blades used to measure petroleum products such as fuels, bio-fuels and refinedliquid hydrocarbons and non corrosive chemicals.Its simple design with only two pairs of blades and one moving rotor makes itexceptionally robust and allows the user to make significant savings onmaintenance costs.
Sectors of applicationOil depots
For oil product reception and loading stations for tank truck,
tank car and ships.
Hydrocarbon transportation
Distribution of fuel oil or fuel by road tanker.
Aircraft refuelling
Aircraft dispensers and aircraft fuelling tankers.
Army
Depot supplies and loading of trucks.
Transport companies
Refuelling of locomotives, trucks and public transport coaches.
Marine applications
Refuelling of ships.
Mining sites
Refuelling of trucks or site machinery.
Operating principleThe product enters the measuring chamber following the
direction of the arrow. The rotor and blades assembly (1-2) is
set in motion by the pressure of the liquid on blades. A certain
amount of liquid (3) is held between 2 blades and then directed
to the discharge manifold. The volume of liquid measured at
each rotation is therefore equal to 4 times the measured
quantity (3). The smooth curves the meter pieces provide a
steady, non-fluctuating flow resulting in low head loss.
Key pointsReduced pressure loss
0.3 to 0.5 bar at maximum flow rate.
Low maintenance costs
Simple and robust design with mechanical components
interchangeable between the different models.
Stability of measurements
Accuracy of measurement guaranteed over a period of many
years without any drift in the calibration curve.
Modular design
Wide range of accessories for performing customized
measurement applications.
Robust construction
Flowmeter manifold is separated from measurement chamber
to eliminate any possible influence of external mechanical
stresses on measurement accuracy.
Few moving parts.
Metering Solutions
Countum Group
ZC 17
Positive Displacement Meter
1
3
2
Measuringsystems
Flowcomputers
AccessoriesFlow meters
B037-IFC-GB-REV3-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08
As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.
Your local contactIFC InflowUnit 3, Ryder Way, Basildon, Essex, SS13 1QH, United KindomPhone: +44 (0) 1268 596 900E-mail: [email protected]
Headquarters and Sales DepartmentPARIS NORD IIBat. le Gauguin - 47, allée des ImpressionnistesBP 85012 Villepinte95931 Roissy CDG Cedex FRANCEPhone: +33 (0)1 48 63 02 11 E-mail: [email protected]: www.satam.eu www.ifcinflow.com
Technical data - PD meter ZC 17Model ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330
Application Custody transfer metering of liquid hydrocarbons
Max. Flowrate (m3/h - L/mn - USGPM) 12-200-53 24-400-105 48-800-210 80-1333-360 150-2500-660 250-4166-1100 330-5500-1453
Min. Flowrate (m3/h - L/mn - USGPM) 1.2-20-5.3 2.4-40-10.5 4.8-80-21 8-133-36 15-250-66 25-416-110 33-550-145
Connections DN 2’’ 2’’ 2’’ 3’’ 4’’ 6’’ 8’’
Flanges (standard) Standard Satam ASA 150 RF
Flanges (option) ASA 150 RF DIN28463TW1 DIN28463TW3
Other flanges upon request
Materials Manifold Aluminum Steel or ductile iron or
aluminum
Steel or ductile iron
Casing Aluminum Aluminum or
Ni resist Iron
Ductile iron or Ni resist iron
Front and back cover Carbon steel with protective coating
Rotor - Blades - Gaskets Aluminum - Graphite - Viton (option nitrile)
Operating conditions Max. pressure (operation) 10 bar -150 PSI
Max. pressure (EC/MID certificate) 8 bar6 bar (gasoline, kerosene)
8 bar (diesel oil, ethanol)10 bar
Max. viscosity MID : 20mm²/s (cSt) - Operation : 800 mm²/s (cSt) MID : 57mm²/s
Liquid temperature -10 °C to +55 °C
Ambient temperature Standard : -20 °C to +55 °C - Option : -40 °C to +55 °C
Consult us for higher or lower temperatures
Pressure drop at max flowrate, 3,7 mm²/s (cSt) 0.45 0.35
Internal construction Cyclic volume (L - USG) 0,33-0.08 0,40-0.10 0,80-0.21 2,27-0.6 4,54-1.2 6,82-1.8 9.09-2.4
Metrological performances Accuracy < 0,15 % / Option < 0,1 % For 10 : 1 measuring range
Repeatability < 0,02 %
Installation ATEX certification Zone 1 - II 2 G
Custody transfer approval EC-MID Evaluation Certificate N° LNE-11052
Type Compliance Certificate OIML R117 n°LNE-24351
Dimensions (mm) and weight ZC17 12 ZC17 24 ZC17 48 ZC17 80 ZC17 150 ZC17 250 ZC17 330
Distance between flanges (A) 180 180 180 356 432 400 400
Width (B) 290 290 290 356 432 400 400
Depth (C) with mechanical register
with pulser
220
186
220
186
246
266
365
272
492
399
620
526
746
653
Height (D) with mechanical register
with pulser
368
260
406
260
406
260
502
502
521
521
568
568
625
625
Weight (kg) with mechanical register 18 22 26 75 95 155 200
Flanges positions
Flanges ASA150 with mechanical register PH1, PH2PH1, PH2, PV1, PV2, PV3, PV4
Flanges ASA150 with pulser PH1, PH2, PV1, PV2, PV3, PV4
Flanges TW with mechanical register or pulser - - -PH1, PH2,
PV1 to PV10
PH1, PH2,
PV1 to PV6- -
ZC 17- 80, 150, 250 & 330
ZC 17- 12, 24 & 48
Metering Solutions
Countum Group
Metering Solutions
Countum Group
ZCE 5
Measuringsystems
Flowcomputers
AccessoriesFlow meters
ZCE 5 vertical metering unit is designed for truck and train tankers loading stations
in a top or bottom loading configuration.
ZCE5 space-saving configuration enables easy installation in smaller facilities and
in compact pipeline network.
Sectors of application
• Tanker trucks and railcars loading applications
• Preparation of bio-fuels by means of online or batch
blending
• Measurement of white products and bio-fuels
• Additive injection control
High reliability measuring system
Ready-made technology
ZCE 5 vertical measuring units are completely assembled,
wired and tested in the production facility in order to ensure
a maximum reliability.
Measurement stability and accuracy
Measurement accuracy guaranteed over a period of many
years without any deviation in the calibration curve.
Modular design
Extensive line of accessories to create customized
measurement applications.
Key points
Low installation costs
Complete and ready-to-install compact measuring unit
including strainer, air eliminator, PD meter, valve
and register.
Low maintenance costs
Simple and robust construction with minimal moving parts.
Interchangeable mechanical components.
Space-saving installation
Compact metering unit for installation in smaller areas
and in vertical pipeline networks.
A safe and easy-to-use technology
Automatic gas elimination system to start loading
operation with empty pipe.
Filtering system with automatic clogging detection.
Communication
Direct communication with supervisory system.
Vertical measuring unit for truck and railcar loading
B026-IFC-GB-REV0-09/17-Marketing SatamDesign & printing : TACTIC IMPRESSIONS - 01 39 86 19 08
Technical data - Vertical measuring unit for loading
Model ZCE 5-80 ZCE 5-150
Maximum flow rate m3/h - L/mn - USGPM 80 - 1333 - 360 150 - 2500 - 660
Connections Flanges 3'' ASA 150 RF 4'' ASA150 RF
Description Compact vertical metering unit
Measured parameters Actual volume, temperature-corrected volume*, mass*, flow rate**, temperature*
(* : only for electronic register version, ** : option for mechanical register version)
Measured liquids Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol,
kerosene, fatty acid methyl ester, oils
Equipment Strainer - Gas elimination device Model EC 29
50 to 450 filtering (270 to 40 Mesh) depending on the liquid
Gas release controlled by float and differential valve
PD meter ZC 17-80 ZC 17-150
Temperature measurement 4-wire Pt100 (option for electronic calculator version)
Multi-function valve XAD 37 XAD 36
Small and large flow authorisation, flow limitation
Electrical control or mechanical control
Flow register Mechanical register model VR with pre set*, printer*, pulser*
or Equalis electronic register with display, secure archiving of transactions
Operating conditions Pressure 10 bar max.
Viscosity 20cSt max. – Contact us about higher viscosities
Liquid temperature -10 à +80 °C
Ambient temperature Standard -25 to +55 °C ; Option -40 to +55 °C
Contact us about higher or lower temperatures
Metrological performance Volume accuracy ≤±0.15% - Option ≤±0.1% - for measurement range of 10 : 1
Volume repeatability ≤ ±0.02 %
Temperature accuracy ≤ 0.5 °C
Installation ATEX certification Zone 1 - II 2 G
Custody transfer approval MID - CE type approval n° LNE 6184
Type compliance certificate OIML R117 n°LNE-24351
Dimensions and weight net weight without extension 200 kg 240 kg
Net weight with extension 235 kg 275 kg
As Satam regularly improves its products to ever better respond to evolving market and regulatory requirements, it reserves the right to change any of the specifications of these products, and this without prior notice.