enhanced … m e d i c a l d e v i c e s … safety for
TRANSCRIPT
Cleaner:
Easier to clean and easier to flush (99.34% clear with just 5 cc).
Safer:
Fewer occlusions and fewer bloodstream infections.
Transparent:
You can see what you are doing at all times.
Standardisation:
Continuity of care for all access points (CVC, PICCs and peripherals).
Areas of use:
- ICU - Oncology - Haematology - Paediatric- HIV - Others
K-NE CTNEEDLE FREE INJECTION CONNECTOR
M E D I C A L D E V I C E S
Fresenius Kabi Deutschland GmbHD-61346 Bad Homburg v. d. H.Tel.: +49 (0) 61 72/686 82 00Fax: +49 (0) 61 72/686 82 [email protected]
Enhanced …
… safety for patients and health care professionals 4, 5, 6, 7, 8, 9
1Medegen MMS, Inc.: 8-Day Microbiological Challenge of the MaxPlus TM Positive Flow Connector.
2Medegen MMS, Inc.: MaxPlus TM 72-Hour Activation Testing.
3 Test Method: Each device was assessed 3 times with a BD 10cc Luer lock syringe. The syringe was twisted on and o� with normal hand torque. One drop of Glo Germ TM was applied on the top of each connector. The connector remained upright with the Glow GermTM drop for 1 minute. After 1 minute elapsed each valve was laid on its side for 50 minutes. After 50 minutes each connector was cleaned with 70% IPA swab. The 70% IPA was applied with standard hospital disinfection procedure (circular motion, 3 times over the top). The connectors were then placed under a black light to view the remaining Glo Germ TM.
4Victor Lange, MSPH; Janice Tarwater, RN: Infection risk associated with a closed Luer access device.
5 Bouza E, Munoz P, Lopez-Rodriguez J, et al.: A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: a prospective randomized study. Journal of Hospital Infection, 2003; (54) 279–87.
6 Mermel LA., et al.: Guidelines for the Management of Intravascular Catheter-Related Infections. CID, May 2001; 32; 1249–1272.
7Jarvis WM.: Presented at the Society for Healthcare Epidemiology of America annual conference. Los Angeles, April 2005.
8 Cosgrove SE, Bradley K, McKee C, et al.: Increase in catheter related bloodstream infections (CR-BSI) in pediatric intensive care units temporally associated with a change in needleless intravenous port. SHEA, April 2005; Abstract 26.
9 O‘Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, et al.: Guidelines for the Prevention of Intravascular Catheter- Related Infections. CDC: MMWR, August 2002; 51; 1–26.
1. Prime Remember to prime before use.
Please invert while filling and gently tap valve to purge all air.
2. Swab Always disinfect before
accessing according to protocol.
3. Flush Flush after each use according to protocol.
4. D isconnect While disconnecting rest
finger firmly on plunger -> positive displacement.
Handling
Tru-Swab TM top becomes clean after swabbing …
… while “nooks and crannies“ in ordinary valves harbour orange dye representing bacteria. 3
Luer slipInsert firmly and give a quarter turn. Do not leave the connection unattended.
Dual seal technology guarantees no air entrance during activation According to EN 20594-1
Proven technology
Unique patented technology that provides a flat and smooth top for optimal swabability
� L ipid-resistant
� Compatible with chemotherapeutics
� DE HP-free
� Fits with Luer lock
� MR I compatibility
� Applicable to blood products
� Latex-free
� Fits with Luer slip
Product range
All products are DEHP-free and latex-free
Infudrop Air 21, K-NECT, 2Y, BCV, LLM
M48413645
Infudrop Air 21, K-NECT, Y, LLM
M48413545
Extension, K-NECT, microbore
M78401045
Extension, K-NECT, Y, LLM
M77401845
Transfusion set
Sangodrop B 200µm, K-NECT, Y, LLM
M61413545 X
Extension 2-fold, K-NECT, LLM
M76400245
Extension 3-fold, K-NECT, BCV, LLM
M76400345
Xcontaining DEHP
Burette set Single valve
Universal burette, 150 ml, K-NECT
M63013645
K-NECT, needle free injection connector
M79400845
MS 31, standard infusion set with 1 K-NECT
z072931F X
MS 81, primary set with 2 K-NECT
z072981F X
Dedicated setsMS sets to be used with OPT IMA MS and Module M V P MS infusion pumps
Xcontaining DEHP
Volumat Lines to be used with Volumat Agilia pumps
VL ST02, standard infusion set with 1 K-NECT
M46441900
VL ST22, standard infusion set with 2 K-NECT
M46442500
Paediatric infusion set with150 ml graduated burette,
1 K-NECT
M46445200
Dual set for infusion,with 2 K-NECT
M46443100
Gravity sets Extension sets
Oncology set for multi- infusion in closed system,
4 K-NECT
M46444000
Paediatric infusion set,1 K-NECT
M46442200
Infusion set for drugs incompatible with PVC,
1 K-NECT
M46443400
PVC-free
PVC-free
Protocol 8 days 1
Functional activities 204 2
replace whenever first is reached
Flow rate 183 ml/min
Fill volume 0.5 ml
Back pressure 45 psi (3.103 bar)