Cleaner: Easier to clean and easier to flush (99.34% clear with just 5 cc). Safer: Fewer occlusions and fewer bloodstream infections. Transparent: You can see what you are doing at all times. Standardisation: Continuity of care for all access points (CVC, PICCs and peripherals). Areas of use: - ICU - Oncology - Haematology - Paediatric - HIV - Others K-NE CT NEEDLE FREE INJECTION CONNECTOR MEDI CA L DEVI CES Fresenius Kabi Deutschland GmbH D-61346 Bad Homburg v. d. H. Tel.: +49 (0) 61 72/686 82 00 Fax: +49 (0) 61 72/686 82 39 [email protected] www.fresenius-kabi.de Enhanced … safety for patients and health care professionals 4, 5, 6, 7, 8, 9 1 Medegen MMS, Inc.: 8-Day Microbiological Challenge of the MaxPlus TM Positive Flow Connector. 2 Medegen MMS, Inc.: MaxPlus TM 72-Hour Activation Testing. 3 Test Method: Each device was assessed 3 times with a BD 10cc Luer lock syringe. The syringe was twisted on and off with normal hand torque. One drop of Glo Germ TM was applied on the top of each connector. The connector remained upright with the Glow Germ TM drop for 1 minute. After 1 minute elapsed each valve was laid on its side for 50 minutes. After 50 minutes each connector was cleaned with 70% IPA swab. The 70% IPA was applied with standard hospital disinfection procedure (circular motion, 3 times over the top). The connectors were then placed under a black light to view the remaining Glo Germ TM . 4 Victor Lange, MSPH; Janice Tarwater, RN: Infection risk associated with a closed Luer access device. 5 Bouza E, Munoz P, Lopez-Rodriguez J, et al.: A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: a prospective randomized study. Journal of Hospital Infection, 2003; (54) 279–87. 6 Mermel LA., et al.: Guidelines for the Management of Intravascular Catheter-Related Infections. CID, May 2001; 32; 1249–1272. 7 Jarvis WM.: Presented at the Society for Healthcare Epidemiology of America annual conference. Los Angeles, April 2005. 8 Cosgrove SE, Bradley K, McKee C, et al.: Increase in catheter related bloodstream infections (CR-BSI) in pediatric intensive care units temporally associated with a change in needleless intravenous port. SHEA, April 2005; Abstract 26. 9 O‘Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, et al.: Guidelines for the Prevention of Intravascular Catheter- Related Infections. CDC: MMWR, August 2002; 51; 1–26.

Upload: others

Post on 16-Oct-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Enhanced … M E D I C A L D E V I C E S … safety for

Cleaner:

Easier to clean and easier to flush (99.34% clear with just 5 cc).

Safer:

Fewer occlusions and fewer bloodstream infections.

Transparent:

You can see what you are doing at all times.

Standardisation:

Continuity of care for all access points (CVC, PICCs and peripherals).

Areas of use:

- ICU - Oncology - Haematology - Paediatric- HIV - Others

K-NE CTNEEDLE FREE INJECTION CONNECTOR

M E D I C A L D E V I C E S

Fresenius Kabi Deutschland GmbHD-61346 Bad Homburg v. d. H.Tel.: +49 (0) 61 72/686 82 00Fax: +49 (0) 61 72/686 82 [email protected]

Enhanced …

… safety for patients and health care professionals 4, 5, 6, 7, 8, 9

1Medegen MMS, Inc.: 8-Day Microbiological Challenge of the MaxPlus TM Positive Flow Connector.

2Medegen MMS, Inc.: MaxPlus TM 72-Hour Activation Testing.

3 Test Method: Each device was assessed 3 times with a BD 10cc Luer lock syringe. The syringe was twisted on and o� with normal hand torque. One drop of Glo Germ TM was applied on the top of each connector. The connector remained upright with the Glow GermTM drop for 1 minute. After 1 minute elapsed each valve was laid on its side for 50 minutes. After 50 minutes each connector was cleaned with 70% IPA swab. The 70% IPA was applied with standard hospital disinfection procedure (circular motion, 3 times over the top). The connectors were then placed under a black light to view the remaining Glo Germ TM.

4Victor Lange, MSPH; Janice Tarwater, RN: Infection risk associated with a closed Luer access device.

5 Bouza E, Munoz P, Lopez-Rodriguez J, et al.: A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: a prospective randomized study. Journal of Hospital Infection, 2003; (54) 279–87.

6 Mermel LA., et al.: Guidelines for the Management of Intravascular Catheter-Related Infections. CID, May 2001; 32; 1249–1272.

7Jarvis WM.: Presented at the Society for Healthcare Epidemiology of America annual conference. Los Angeles, April 2005.

8 Cosgrove SE, Bradley K, McKee C, et al.: Increase in catheter related bloodstream infections (CR-BSI) in pediatric intensive care units temporally associated with a change in needleless intravenous port. SHEA, April 2005; Abstract 26.

9 O‘Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, et al.: Guidelines for the Prevention of Intravascular Catheter- Related Infections. CDC: MMWR, August 2002; 51; 1–26.

Page 2: Enhanced … M E D I C A L D E V I C E S … safety for

1. Prime Remember to prime before use.

Please invert while filling and gently tap valve to purge all air.

2. Swab Always disinfect before

accessing according to protocol.

3. Flush Flush after each use according to protocol.

4. D isconnect While disconnecting rest

finger firmly on plunger -> positive displacement.

Handling

Tru-Swab TM top becomes clean after swabbing …

… while “nooks and crannies“ in ordinary valves harbour orange dye representing bacteria. 3

Luer slipInsert firmly and give a quarter turn. Do not leave the connection unattended.

Dual seal technology guarantees no air entrance during activation According to EN 20594-1

Proven technology

Unique patented technology that provides a flat and smooth top for optimal swabability

� L ipid-resistant

� Compatible with chemotherapeutics

� DE HP-free

� Fits with Luer lock

� MR I compatibility

� Applicable to blood products

� Latex-free

� Fits with Luer slip

Product range

All products are DEHP-free and latex-free

Infudrop Air 21, K-NECT, 2Y, BCV, LLM

M48413645

Infudrop Air 21, K-NECT, Y, LLM

M48413545

Extension, K-NECT, microbore

M78401045

Extension, K-NECT, Y, LLM

M77401845

Transfusion set

Sangodrop B 200µm, K-NECT, Y, LLM

M61413545 X

Extension 2-fold, K-NECT, LLM

M76400245

Extension 3-fold, K-NECT, BCV, LLM

M76400345

Xcontaining DEHP

Burette set Single valve

Universal burette, 150 ml, K-NECT

M63013645

K-NECT, needle free injection connector

M79400845

MS 31, standard infusion set with 1 K-NECT

z072931F X

MS 81, primary set with 2 K-NECT

z072981F X

Dedicated setsMS sets to be used with OPT IMA MS and Module M V P MS infusion pumps

Xcontaining DEHP

Volumat Lines to be used with Volumat Agilia pumps

VL ST02, standard infusion set with 1 K-NECT

M46441900

VL ST22, standard infusion set with 2 K-NECT

M46442500

Paediatric infusion set with150 ml graduated burette,

1 K-NECT

M46445200

Dual set for infusion,with 2 K-NECT

M46443100

Gravity sets Extension sets

Oncology set for multi- infusion in closed system,

4 K-NECT

M46444000

Paediatric infusion set,1 K-NECT

M46442200

Infusion set for drugs incompatible with PVC,

1 K-NECT

M46443400

PVC-free

PVC-free

Protocol 8 days 1

Functional activities 204 2

replace whenever first is reached

Flow rate 183 ml/min

Fill volume 0.5 ml

Back pressure 45 psi (3.103 bar)