    Team & Members

    Abstract Intention

    Existing System

    Projected System

    Block Diagram Block Explanation

    Software and hardware

    Experimental results

    Advantages

    Disadvantages

    Conclusion

    Future works

    References

  • 7/29/2019 Energy management system- prototype

    3/47

    Pradeepa.S 31608106066

    Sabreen Taj 31608106074

    Sakthivel.S 31608106078

    Sreerekha.R 31608106095

    GUIDEMr. Ananth Ravindran (Asst professor)

  • 7/29/2019 Energy management system- prototype

    4/47

    The development of an Automatic Power

    Meter Reading (APMR) system is presented in

    this paper. The APMR system is consists of

    Digital Power meters installed in everysubstation. The Digital Power meter (DPM) is

    a single phase digital kWh power meter with

    embedded ZIGBEE modem which utilizes the

    ZIGBEE network to send its power usage

    reading wirelessly. At the receiver side an

    LCD displays the current and voltage readings

    and the power along with power loss, update

    the database.

  • 7/29/2019 Energy management system- prototype

    5/47

    This project aims at wireless communication

    between substations using ZIGBEE module.

    Automatic meter reading (APMR) is an

    effective means of data collection that allowsubstantial saving through the reduction of

    meter re-read , greater data accuracy. With

    the advent of digital technology analog

    electro-mechanical meter is continuouslyreplaced by digital electronic meter.

    ZAPMR has wide coverage and retrieve meter

    reading back wirelessly. The most important

    of these are performance and reliability

  • 7/29/2019 Energy management system- prototype

    6/47

    To implement automatic Power meter

    reading for providing high flexibility,

    accuracy using ZIGBEE Network

  • 7/29/2019 Energy management system- prototype

    7/47

    Meter reading taken manually

    Errors occurred due to less concentration

    Meter reading not accurate

    Huge Manpower needed

  • 7/29/2019 Energy management system- prototype

    8/47

    Meter reading taken automatically using

    zigbee technology

    Normal work happen at any time and

    external conditions Less Manpower

    High Accurate meter reading

  • 7/29/2019 Energy management system- prototype

    9/47

    MicrocontrollerSignal

    Conditioning

    CT

    PT

    Actuator

    LCD

    Serial

    Communication

    RS232

    ZIGBEE

    Serial

    communication

    Network

  • 7/29/2019 Energy management system- prototype

    10/47

    Input power supply given to consumer

    through actuator

    Actuator acts as a switch, it is controlled

    by microcontroller Current transformer and potential

    transformer are used measure the power by

    microcontroller

    Display unit are used to display meterreadings and bill status

    The meter reading send to admin center

    through ZIGBEE using serial communication

  • 7/29/2019 Energy management system- prototype

    11/47

  • 7/29/2019 Energy management system- prototype

    12/47

  • 7/29/2019 Energy management system- prototype

    13/47

    The operation of power supply circuits builtusing filters, rectifiers, and then voltageregulators. Starting with an AC voltage, asteady DC voltage is obtained by rectifying

    the AC voltage, Then filtering to a DC level,and finally, regulating to obtain a desiredfixed DC voltage. The regulation is usuallyobtained from an IC voltage regulator Unit,

    which takes a DC voltage and provides asomewhat lower DC voltage, Which remainsthe same even if the input DC voltage varies,or the output Load connected to the DCvoltage changes.

  • 7/29/2019 Energy management system- prototype

    14/47

  • 7/29/2019 Energy management system- prototype

    15/47

    PIC16F877A microcontroller is used for this

    project

    It is 8-bit Microcontroller

    System is RISC Architecture It has Small set of Instruction set

    It has 35-Instructions only

    Compatibility: avail 28/40 Pin ICs

  • 7/29/2019 Energy management system- prototype

    16/47

    Operating Speed Max 20 MHz, Voltage-(2-

    5.5)v

    Memory:

    Flash Program 8Kx14 Words,RAM 368 Bytes,

    EEPROM Data Memory 256 Bytes

    Low power, High speed Flash/EEPROM

    Technology

  • 7/29/2019 Energy management system- prototype

    17/47

    It has 5 Ports for Internal and External usage

    It has on chip Timers. 3 Timers are avail

    It has in built Analog to Digital Converter

    In built Multiplexer availability for signalSelection

    It has serial as well as Parallel

    Communication facilities

    In built Capture, Compare and Pulse width

    modulation

  • 7/29/2019 Energy management system- prototype

    18/47

  • 7/29/2019 Energy management system- prototype

    19/47

  • 7/29/2019 Energy management system- prototype

    20/47

  • 7/29/2019 Energy management system- prototype

    21/47

    PTs or VTs are the most common devices

    used. These devices are conventional

    transformers with two or three windings (one

    primary with one or two secondary). They

    have an iron core and magnetically couple

    the primary and secondary. The high side

    winding is constructed with more copper

    turns than the secondary(ies), and any

    voltage impressed on the primary winding is

    reflected on the secondary windings in direct

    proportion to the turns ratio or PT ratio.

  • 7/29/2019 Energy management system- prototype

    22/47

  • 7/29/2019 Energy management system- prototype

    23/47

  • 7/29/2019 Energy management system- prototype

    24/47

  • 7/29/2019 Energy management system- prototype

    25/47

    RS232 standard is anasynchronous serialcommunication method.

    The word serial means, that

    the information is sent one bitat a time.

    Asynchronous tells us that theinformation is not sent inpredefined time slots.

    Data transfer can start at anygiven time and it is the task ofthe receiver to detect when amessage starts and ends.

  • 7/29/2019 Energy management system- prototype

    26/47

  • 7/29/2019 Energy management system- prototype

    27/47

  • 7/29/2019 Energy management system- prototype

    28/47

  • 7/29/2019 Energy management system- prototype

    29/47

  • 7/29/2019 Energy management system- prototype

    30/47

  • 7/29/2019 Energy management system- prototype

    31/47

    Diagram that a relay uses an electromagnet.This is a device consisting of a coil of wire

    wrapped around an iron core. When electricity

    is applied to the coil of wire it becomes

    magnetic, hence the term electromagnet. The

    A B and C terminals are an SPDT switch

    controlled by the electromagnet. When

    electricity is applied to V1 and V2, the

    electromagnet acts upon the SPDT switch so

    that the B and C terminals are connected.

    When the electricity is disconnected, then the

    A and C terminals are connected. It isimportant to note that the electromagnet is

    magnetically linked to the switch but the two

    are NOT linked electrically

  • 7/29/2019 Energy management system- prototype

    32/47

  • 7/29/2019 Energy management system- prototype

    33/47

    ZigBee is a Ad-hoc networking technology for LR-WPAN

    Based On IEEE 802.15.4 standard that defines the PHY

    and Mac Layers for ZigBee.

    Intended for 2.45 Ghz , 868 Mhz and 915 Mhz Band. Low in cost ,complexity & power consumption as

    compared to competing technologies.

    Intended to network inexpensive devices

    Data rates touch 250Kbps for 2.45Ghz ,40 Kbps 915Mhzand 20Kbps for 868Mhz band.

  • 7/29/2019 Energy management system- prototype

    34/47

  • 7/29/2019 Energy management system- prototype

    35/47

  • 7/29/2019 Energy management system- prototype

    36/47

  • 7/29/2019 Energy management system- prototype

    37/47

  • 7/29/2019 Energy management system- prototype

    38/47

  • 7/29/2019 Energy management system- prototype

    39/47

    MPLAB IDE

    Hi-tech c compiler

    Visual basic c++ 6.0

  • 7/29/2019 Energy management system- prototype

    40/47

    ORCAD design

    Visual basic

  • 7/29/2019 Energy management system- prototype

    41/47

    Using zigbee accurate values is being taken

    for nearly two substations and is being

    transmitted to the administrative office.

    In this external load is being added . Loadscan be varied by using potentiometer.

    Since data logging is done it is very useful to

    get back all the data.

    Automatic power shut down is done in caseof high input given.

  • 7/29/2019 Energy management system- prototype

    42/47

    Less operation cost

    Less manpower

    High efficiency and reliability

  • 7/29/2019 Energy management system- prototype

    43/47

    Utility metering

    Power Industries

  • 7/29/2019 Energy management system- prototype

    44/47

    In this paper we have shown the updated power readings and

    the way of detecting power loss. Traditional meter reading for

    electricity consumption is done by human operator fromstation to station. This requires huge number of labor

    operators and long working hour to achieve complete area

    data reading. Human being may make errors while noting so to

    overcome all those problems we have introduced ZIGBEE awireless modem The development of a ZIGBEE Automatic

    Power Meter Reading (APMR) system is presented in this paper.

    So by using ZIGBEE huge work is reduced and also labors. It is a

    wireless modem throughwhich readings are displayed and can

    be monitored without any effort and also readings are data

    logged for future reference. At the receiver side the meter

    reading , updated database is obtained.

  • 7/29/2019 Energy management system- prototype

    45/47

  • 7/29/2019 Energy management system- prototype

    46/47

  • 7/29/2019 Energy management system- prototype

    47/47

    WEB REFERENCES:

    www.atmel.com

    www.dallas.com

    www.gpsfavorities.comwww.holtek.com

    www.microcontroller.com

    http://www.hp.com/go/HPVEE

    http://www.atmel.com/http://www.dallas.com/http://www.gpsfavorities.com/http://www.holtek.com/http://www.microcontroller.com/http://www.hp.com/go/HPVEEhttp://www.hp.com/go/HPVEEhttp://www.microcontroller.com/http://www.holtek.com/http://www.gpsfavorities.com/http://www.dallas.com/http://www.atmel.com/