energy management module (emm) accessory ... - utcccs · pdf file2 5. using the no. 6 screw...

12
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53300150-01 Printed in U.S.A. Form 30/38-16SI Pg 1 9-15 Replaces: 30/38-15SI Installation Instructions Part Number 38AP-900---022 CONTENTS SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Install Harness and Make Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Controls Configuration for EMM Options . . . . . . . . . 7 SAFETY CONSIDERATIONS Installation of this accessory can be hazardous due to sys- tem pressures, electrical components, and equipment location (such as a roof or elevated structure). Only trained, qualified installers and service technicians should install, start up, and service this equipment. When installing this accessory, observe precautions in the literature, labels attached to the equipment, and any other safety precautions that apply. Follow all safety codes. Wear safety glasses and work gloves. Use care in handling and installing this accessory. GENERAL The energy management module (EMM) accessory (Fig. 1) package is required for additional temperature reset, demand limit, and remote set point features of the ComfortLink controls for 30MP, 30RAP and 38AP units. Chilled water temperature reset by return water, outside air or space temperature does NOT require the addition of this accessory. The following ad- ditional features are supported by this accessory: temperature reset by 4 to 20 mA field-supplied signal. demand limit control via field-supplied two-step switch input. demand limit control by 4 to 20 mA field-supplied signal. support of unoccupied operation for ice making through field-supplied contacts (30MP, 30RAP only). cooling set point control by 4 to 20 mA field-supplied signal. ACCESSORY PACKAGE CONTENTS LEGEND INSTALLATION NOTE: Component arrangement drawings and wiring dia- grams show available options that may not be applicable to your unit. 1. Inspect the package contents for missing or damaged parts. File a claim with shipping agency if parts are dam- aged. Notify your Carrier representative if any items are missing. 2. Open and tag all electrical disconnects. 3. Access control box: a. Model 30RAP010-030, 30MP015-071 and 38AP025-030 units: Open control box door and remove inner cover. b. Model 30RAP035-150 and 38AP040-130 units: Open center control box door. 4. For 30RAP and 38AP units, loosen the four screws secur- ing the scrolling marquee display bracket. Lift the bracket up and slide it in the holding slots at the top of its mount- ing bracket. For 30MP units, carefully suspend the display bracket from the wiring harness. WARNING Electrical shock can cause personal injury and death. Shut off all power to this equipment during installation. There may be more than one disconnect switch. Tag all discon- nect locations to alert others not to restore power until work is completed. ITEM PART NO. QUANTITY Energy Management Module 30GT515218 1 Harness (38APD,S025-060) 38APHLSBCE-A00 1 Harness (38APD,S065-130) 38APHLSLCE-A10 1 Harness, EMM to LVT (30RAP, 30MP) 38APHSCALE-A00 1 Harness, EMM to MBB/EXV (Power - 30RAP, 30MP) 38APHSCALECA10 1 Harness, EMM to MBB/EXV (Comm. - 30RAP, 30MP) 38APHSCALECA00 1 Harness, EMM to AUX (Comm. - 30MP) 38APHSCALXCA00 1 Screw, no. 6, 1-in. long AL56AU130 1 Wire Tie 4 EXV Electronic Expansion Valve LVT Low Voltage Terminal MBB Main Base Board WARNING Before beginning installation of this equipment, be sure all power to the unit is disconnected, and that tags are properly placed to alert others. Electrical shock can cause personal injury and death. 30MP015-071, 30RAP010-150 38APD025-130, 38APS025-065 Energy Management Module (EMM) Accessory 50/60 Hz

Upload: vulien

Post on 26-Mar-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53300150-01 Printed in U.S.A. Form 30/38-16SI Pg 1 9-15 Replaces: 30/38-15SI

Installation InstructionsPart Number 38AP-900---022

CONTENTS

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12Install Harness and Make Wire

Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Controls Configuration for EMM Options . . . . . . . . . 7

SAFETY CONSIDERATIONS

Installation of this accessory can be hazardous due to sys-tem pressures, electrical components, and equipment location(such as a roof or elevated structure).

Only trained, qualified installers and service techniciansshould install, start up, and service this equipment.

When installing this accessory, observe precautions in theliterature, labels attached to the equipment, and any othersafety precautions that apply.• Follow all safety codes.• Wear safety glasses and work gloves.• Use care in handling and installing this accessory.

GENERALThe energy management module (EMM) accessory (Fig. 1)

package is required for additional temperature reset, demandlimit, and remote set point features of the ComfortLink controlsfor 30MP, 30RAP and 38AP units. Chilled water temperaturereset by return water, outside air or space temperature doesNOT require the addition of this accessory. The following ad-ditional features are supported by this accessory:• temperature reset by 4 to 20 mA field-supplied signal.• demand limit control via field-supplied two-step switch

input.• demand limit control by 4 to 20 mA field-supplied

signal.• support of unoccupied operation for ice making through

field-supplied contacts (30MP, 30RAP only).• cooling set point control by 4 to 20 mA field-supplied

signal.

ACCESSORY PACKAGE CONTENTS

LEGEND

INSTALLATION

NOTE: Component arrangement drawings and wiring dia-grams show available options that may not be applicable toyour unit.

1. Inspect the package contents for missing or damagedparts. File a claim with shipping agency if parts are dam-aged. Notify your Carrier representative if any items aremissing.

2. Open and tag all electrical disconnects.3. Access control box:

a. Model 30RAP010-030, 30MP015-071 and38AP025-030 units: Open control box door andremove inner cover.

b. Model 30RAP035-150 and 38AP040-130 units:Open center control box door.

4. For 30RAP and 38AP units, loosen the four screws secur-ing the scrolling marquee display bracket. Lift the bracketup and slide it in the holding slots at the top of its mount-ing bracket. For 30MP units, carefully suspend the display bracketfrom the wiring harness.

WARNING

Electrical shock can cause personal injury and death. Shutoff all power to this equipment during installation. Theremay be more than one disconnect switch. Tag all discon-nect locations to alert others not to restore power until workis completed.

ITEM PART NO. QUANTITYEnergy Management Module 30GT515218 1Harness (38APD,S025-060) 38APHLSBCE-A00 1Harness (38APD,S065-130) 38APHLSLCE-A10 1Harness, EMM to LVT(30RAP, 30MP) 38APHSCALE-A00 1

Harness, EMM to MBB/EXV(Power - 30RAP, 30MP) 38APHSCALECA10 1

Harness, EMM to MBB/EXV(Comm. - 30RAP, 30MP) 38APHSCALECA00 1

Harness, EMM to AUX(Comm. - 30MP) 38APHSCALXCA00 1

Screw, no. 6, 1-in. long AL56AU130 1Wire Tie — 4

EXV — Electronic Expansion ValveLVT — Low Voltage TerminalMBB — Main Base Board

WARNING

Before beginning installation of this equipment, be sure allpower to the unit is disconnected, and that tags are properlyplaced to alert others. Electrical shock can cause personalinjury and death.

30MP015-071, 30RAP010-15038APD025-130, 38APS025-065

Energy Management Module (EMM) Accessory50/60 Hz

2

5. Using the no. 6 screw provided and the existing retainingclips in the control box, mount the EMM module to theback of the control box. See Fig. 2-8 for the mounting lo-cation of each unit.

6. The board address is set through a 4-position DIP switch.All switches should be set to ON.

LEGEND FOR FIG. 2-8CB — Circuit BreakerCCB — Compressor Circuit BreakerCXB — Compressor Expansion BoardEMM — Energy Management ModuleEQUIP — EquipmentFB — Fuse BlockGND — GroundLVT — Low Voltage TerminalMBB — Main Base BoardTB — Terminal BlockTRAN — Transformer

Terminal Block Connection

CEBD430351-0396-01C

TE

ST

1

CE

PL1

3035

1-01

PW

R

TEST 2

J1 J2

J4 J3

J5

J6J7

LEN

STATUS

RED LED - STATUSGREEN LED -LEN (LOCAL EQUIPMENT NETWORK)

ADDRESSDIP SWITCH

Fig. 1 — EMM Board

3

LVT

Fig. 2 — Mounting EMM — 38AP025-030 Units

a30-4937

See Legend on page 2.

LVT

Fig. 3 — Mounting EMM — 38AP040-060 Units

a30-4938See Legend on page 2.

4

LVT

Fig. 4 — Mounting EMM — 38AP065-130 Unitsa30-4939

See Legend on page 2.

EMM EXV

LON

AUX

UPC

TB1 TB4

CSB-A1

MBB

CHCCCB

FB-1TRAN

DISCONNECTOPTION/TB

C-A1MM

MS-CWP1

CWP1

MS-CWP2

CWP2

LVT

Fig. 5 — Mounting EMM — 30RAP010 and 015 Unitsa30-4940

See Legend on page 2.

5

EMM EXV

CCB-1

TB1

TB4

CHC

AUX

LON UPC

FC1/MM

CSB-A1

MBBC-A1

FB-3TRAN

CCB-2

CSB-A2

DISCONNECTOPTION/TB

FC2 C-A2

FB-1

CWP1 CWP2

MS-CWP1

MS-CWP2

LVTa30-

Fig. 6 — Mounting EMM — 30RAP018-030 Units

See Legend on page 2.

TRAN-1

CB-1 CB-2 FCB-1/2/3

TRAN-2CSB-A1 CSB-A2

C-A1

FR-1 FR-2

C-A2

FC-1MM

FC-2 FC-3

AUX LON

EMM EXV

UPC

TB1

TB4

MBB

MS-CWP1

MS-CWP2

FR-3

C-B1

CSB-B1

CB-3CHC

CWP1 CWP2FR-4

CSB-B2

C-B2

CB-4

DISCONNECTOPTION/TB

LVT

a30-4942

Fig. 7 — Mounting EMM — Typical 30RAP035-150 Units, 035-060 Shown

See Legend on page 2.

6

Install Harness and Make Wire Connections38AP025-065 UNITS WITH AUX BOARD — Perform thefollowing procedure to install the harness and make the wiringconnections. See Fig. 9 for wiring.

1. Disconnect the MBB-J3 connector and plug it into theEMM-J3 connector.

2. Install the new harness 38APHLSBCE-A00 provided.a. Install connector labeled MBB-J3 to MBB-J3 and

other end labeled EMM-J4 to EMM-J4.b. Install connector labeled MBB-J2 to MBB-J2 and

other end labeled EMM-J1 to EMM-J1.c. Install connectors labeled EMM-J6 and J7 to

EMM-J6 and J7 and other end labeled LVT-J10 toLVT terminal strip.

38AP025-065 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness and makethe wiring connections. See Fig. 9 for wiring.

Install the new harness 38APHLSBCE-A00 provided.1. Install connector labeled MBB-J3 to MBB-J3 and other

end labeled EMM-J4 to EMM-J4.2. Install connector labeled MBB-J2 to MBB-J2 and other

end labeled EMM-J1 to EMM-J1.3. Install connectors labeled EMM-J6 and J7 to EMM-J6

and J7 and other end labeled LVT-J10 to LVT terminalstrip.

38AP070-130 UNITS WITH AUX BOARD — Performthe following procedure to install the harness and make thewiring connections. See Fig. 10 for wiring.

1. Disconnect the CXB connector J4 and plug it into theEMM connector J3.

2. Install the new harness 38APHLSLCE-A10 provided.a. Install connector labeled CXB-J4 to CXB-J4 and

other end labeled EMM-J4 to EMM-J4.b. Install connector labeled CXB-J2 to CXB-J2 and

other end labeled EMM-J1 to EMM-J1.c. Install connectors labeled EMM-J6 and J7 to

EMM-J6 and J7 and other end labeled LVT-J10 toLVT terminal strip.

38AP070-130 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness and makethe wiring connections. See Fig. 10 for wiring.

Install the new harness 38APHLSLCE-A10 provided.1. Install connector labeled CXB-J4 to CXB-J4 and other

end labeled EMM-J4 to EMM-J4.2. Install connector labeled CXB-J2 to CXB-J2 and other

end labeled EMM-J1 to EMM-J1.3. Install connectors labeled EMM-J6 and J7 to EMM-J6

and J7 and other end labeled LVT-J10 to LVT terminalstrip.

30RAP010-060 UNITS WITH AUX BOARD — Performthe following procedure to install the harness and make thewiring connections. See Fig. 11 for wiring.

1. Disconnect the EXV connector J4 and plug it into theEMM connector J4.

2. Install the new harness 38APHSCALECA00. Install con-nector labeled EXV-J4 to EXV-J4 and other end labeledEMM-J3 to EMM-J3.

3. Install the new harness 38APHSCALECA10. DisconnectMBB connector J2 and plug it into the EMM-J2. Installconnector labeled MBB/EXV-J2 to MBB-J2 and otherend labeled EMM-J1 to EMM-J1.

a30-5984

a30-5986

Fig. 8 — Mounting EMM — 30MP015-071 Units

See Legend on page 2.

7

4. Install the new harness 38APHSCALE-A00. Install con-nectors labeled EMM-J6 and J7 to EMM-J6 and J7 andother end labeled LVT-J10 to LVT terminal strip.

30RAP010-060 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness and makethe wiring connections. See Fig. 11 for wiring.

1. Install the new harness 38APHSCALECA00. Installconnector labeled EXV-J4 to EXV-J4 and other endlabeled EMM-J3 to EMM-J3.

2. Install the new harness 38APHSCALECA10. Install con-nector labeled MBB/EXV-J2 to MBB-J2 and other endlabeled EMM-J1 to EMM-J1.

3. Install the new harness 38APHSCALE-A00. Install con-nectors labeled EMM-J6 and J7 to EMM-J6 and J7 andother end labeled LVT-J10 to LVT terminal strip.

30RAP070-150 UNITS WITH AUX BOARD — Per-form the following procedure to install the harness and makethe wiring connections. See Fig. 12 for wiring.

1. Disconnect the CXB connector J4 and plug it into theEMM connector J4.

2. Install the new harness 38APHSCALECA00. Install con-nector labeled EXV-J4 to CXB-J4 and other end labeledEMM-J3 to EMM-J3.

3. Install the new harness 38APHSCALECA10. Install con-nector labeled MBB/EXV-J2 to CXB-J2 and other endlabeled EMM-J1 to EMM-J1.

4. Install the new harness 38APHSCALE-A00. Install con-nectors labeled EMM-J6 and J7 to EMM-J6 and J7 andother end labeled LVT-J10 to LVT terminal strip.

30RAP070-150 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness and makethe wiring connections. See Fig. 12 for wiring.

1. Install the new harness 38APHSCALECA00. Install theconnector labeled EXV-J4 to CXB-J4 and other end la-beled EMM-J3 to EMM-J3.

2. Install the new harness 38APHSCALECA10. Install con-nector labeled MBB/EXV-J2 to CXB-J2 and other endlabeled EMM-J1 to EMM-J1.

3. Install the new harness 38APHSCALE-A00. Install con-nectors labeled EMM-J6 and J7 to EMM-J6 and J7 andother end labeled LVT-J10 to LVT terminal strip.

30MP015-045 UNITS WITH AUX BOARD — Performthe following procedure to install the harness and make thewiring connections. See Fig. 13 for wiring.

1. Disconnect the MBB connector J3 and plug it into theEMM connector J4.

2. Install the new harness 38APHSCALECA00. Install oneend of the harness in MBB connector J3 and the other endin EMM connector J4.

3. Install the new harness 38APHSCALECA10. Install con-nector labeled MBB/EXV-J2 to MBB-J2 and other endlabeled EMM-J1 to EMM-J1.

4. Install the new harness 38APHSCALE-A00. Install con-nectors labeled EMM-J6 and J7 to EMM-J6 and J7 andthe other end labeled LVT-J10 to J10 of the LVT terminalstrip.

5. Install the new harness 38APHSCALXCA00 provided.Install connector labeled EMM-J3 to EMM-J3 and otherend labeled AUX-J9 to AUX-J9.

30MP015-071 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness and makethe wiring connections. See Fig. 13 for wiring.

1. Install the new harness 38APHSCALECA00. Installone end of the harness in MBB connector J3 and theother end in EMM connector J4.

2. Install the new harness 38APHSCALECA10. Install con-nector labeled MBB/EXV-J2 to MBB-J2 and other endlabeled EMM-J1 to EMM-J1.

3. Install the new harness 38APHSCALE-A00. Install con-nectors labeled EMM-J6 and J7 to EMM-J6 and J7 andthe other end labeled LVT-J10 to J10 of the LVT terminalstrip.

FIELD WIRING CONNECTIONS — Refer to Fig. 2-8 forfield wiring interfaces with the LVT terminal strip.

Controls Configuration for EMM Options —Refer to the 38AP controls and troubleshooting manual forsplit system configuration of controls. Refer to the 30RAPcontrols and troubleshooting manual for AquaSnap® configu-ration of controls for 30RAP units. Refer to the 30MP controlsand troubleshooting manual for configuration of controls for30MP units.

LEGEND FOR FIG. 9-13CXB — Compressor Expansion BoardEMM — Energy Management ModuleFIOP — Factory-Installed OptionLVT — Low Voltage TerminalMBB — Main Base Board

Field Wiring

8

FIOP/

ON

OFF

1 2 3 4 5 6 7 8DARK = SWITCH LOCATION

3

2

1

3

2

1

6

5

4

3

2

1

J9

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

LVT

1

1

2

3

4

5

6

1

2

3

4

5

6

14

15

4

3

12

13

6

5

10

11

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mA

RED

RED

BLU

BLU

PNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

DEMANDLIMITSTEP 1OR Y3

DEMANDLIMITSTEP 2OR Y4

DGS ORMM

FIOP

DUS

2

1

8

7

2

1

8

7

J2

J6DTT

VIO

BRN

RED

BLK

2

12

1RED

BLKJ4

CH1

-

CH11

-

CH9

-

2

12

1

J5CH10

-

TO MM-A

J10

AUX

33

22

11

J2BRN

VIO

22

1

J1

1

33

MBB BRN

RED

33

22

11

J22

J1

1

3

FIOP/ACCESSORY

EMM

Fig. 9 — Typical Wiring Connections (38AP025-065 Units)

a30-4943

A38-7212

24-V POWER CONNECTION

See Legend on page 7.

9

FIOP/

12

11

10

9

8

7

6

5

4

3

2

1

6

5

4

3

2

1J5

CXB4

3

2

1

4

3

2

1

J3

CSBB3

2

3

1

RED

ORN

BRN

CSBA3

2

3

1

RED

ORN

BRN

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

ON

OFF

1 2 3 4 5 6 7 8DARK = SWITCH LOCATION

DUS

3

2

1

3

2

1

6

5

4

3

2

1

J9 2

1

8

7

2

1

8

7

J2

J6DTT

RED

WHT

BLK

DGS ORMM

FIOP

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

LVT

1

1

2

3

4

5

6

1

2

3

4

5

6

14

15

4

3

12

13

6

5

10

11

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mA

RED

RED

BLU

BLU

PNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

DEMANDLIMITSTEP 1OR Y3

DEMANDLIMITSTEP 2OR Y4

VIO REDPL50-1

BRN BLK

PL50-2

RED REDPL50-3

BLK BLK

PL50-4

2

12

1RED

BLKJ4

CH1

-

CH11

-

CH9

-

-

+

G

-

+

G

2

12

1RED

BLKJ5CH10

-

TO MM-A

TO MM-B

(090-130 ONLY)

J10

AUX

Fig. 10 — Typical Wiring Connections (38AP070-130 Units)

a30-4944

A38-7452

24-V POWER CONNECTION

See Legend on page 7.

10

FIOP/

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

1

1

2

3

4

5

6

1

2

3

4

5

6

10

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mAPNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

14

15

4

3

12

13

6

5

11

RED

RED

BLU

BLUDLS STEP 2

DLS STEP 1

LVT

16

17

2

1GRA

GRAICE DONE

J10

Fig. 11 — Typical Wiring Connections (30RAP010-060 Units)

a30-4945

A38-7212

24-V POWER CONNECTION

See Legend on page 7.

33

22

11

J2BRN

VIO

22

1

J1

1

33

MBB BRN

RED

33

22

11

J22

J1

1

3

FIOP/ACCESSORY

EMM

11

FIOP/

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

1

1

2

3

4

5

6

1

2

3

4

5

6

10

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mAPNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

14

15

4

3

12

13

6

5

11

RED

RED

BLU

BLUDLS STEP 2

DLS STEP 1

LVT

16

17

2

1GRA

GRAICE DONE

J10

24-V POWER CONNECTION a30-4945

Fig. 12 — Typical Wiring Connections (30RAP070-150 Units)

a30-5546

See Legend on page 7.

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53300150-01 Printed in U.S.A. Form 30/38-16SI Pg 12 9-15 Replaces: 30/38-15SI

© Carrier Corporation 2015

MAINBASEBOARD

FIOP/

ON

OFF

1 2 3 4 5 6 7 8DARK = SWITCH LOCATION

DUS

3

2

1

3

2

1

6

5

4

3

2

1

J9

2

1

8

7

2

1

8

7

J2

J6DTTRED

WHT

BLK

DGS

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

1

1

2

3

4

5

6

1

2

3

4

5

6

14

15

4

3

12

13

6

5

10

11

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mA

RED

RED

BLU

BLU

PNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

DLS STEP 2

VIO

BRN

RED

BLK

CH1

-

CH11

-

-

+

G

-

+

G

DLS STEP 1

LVT

16

17

2

1GRA

GRAICE DONE

3

44

32

21

1

BLK

WHT

RED

J3

FIOP

J10

AUX2

A38-7212

A38-7211

24-V POWER CONNECTION

Fig. 13 — Typical Wiring Connections (30MP015-71 Units)

See Legend on page 7.

33

22

11

J2BRN

VIO

22

1

J1

1

33

MBB BRN

RED

33

22

11

J22

J1

1

3

FIOP/ACCESSORY

EMM