ENDOZYME ® II GO Endotoxin testing made faster, easier, and ecologically friendly.

Upload: others

Post on 27-Sep-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Endotoxin testing made faster, easier, and ecologically ...€¦ · Endotoxin (CSE) for standard curve points 0.005, 0.05, 0.5, 5 and 50 EU/ mL as well as Positive Product Controls

ENDOZYME® II GOEndotoxin testing made faster, easier,

and ecologically friendly.

Page 2: Endotoxin testing made faster, easier, and ecologically ...€¦ · Endotoxin (CSE) for standard curve points 0.005, 0.05, 0.5, 5 and 50 EU/ mL as well as Positive Product Controls

The rapid GO version of ENDOZYME® II—featuring GOPLATE™—gives you reliable results in fewer steps. It provides endotoxin quantification in liquid samples, and is particularly suited for final product testing and in-process control of raw materials and water.

The streamlined, sustainable endotoxin testing solution.

REDUCED HANDLING TIME. LOWER RISK OF ERROR.

Thanks to the prefilled 96-well GOPLATE, several time-consuming preparation steps have been eliminated, reducing handling time by more than 50% and significantly lowering the risk for human error. The GOPLATE contains the required amounts of Control Standard Endotoxin (CSE) for standard curve points 0.005, 0.05, 0.5, 5 and 50 EU/mL as well as Positive Product Controls (PPCs) 0.5 EU/mL, all in duplicates.

ECOLOGICALLY FRIENDLY ENDOTOXIN TESTING.

• Based on Recombinant Horseshoe Crab Factor C (rFC)

• Consistent, reliable, and sustainable endotoxin detection

• Completely eliminates the need to harvest horseshoe crabs for their blood

CONSISTENCY WITHIN AND BETWEEN LOTS.

• The GOPLATE integrated standard curve provides r > 0.980 and low coefficient of variation (CV)

• Reproducibility in time and between different users, with low variation due to reagents

• Standardized test protocol conforms with pharmacopoeial Bacterial Endotoxin Testing (BET) requirements

>50% reduction of handling time

Minimized error rate

Down to 15 min assay run time for in-process control of water

1

ENDOZYME® II GO Workflow

Add samples and water to the GOPLATE™

Prepare and add Assay Reagent

Run the assay in a fluorescence reader

2

3

©2

018

bio

Mér

ieu

x S

A ·

BIO

ME

RIE

UX

, th

e B

IOM

ER

IEU

X lo

go, E

ND

OZ

YM

E, a

nd

GO

PL

AT

E a

re u

sed

pen

din

g an

d/o

r re

gist

ered

tra

dem

arks

bel

on

gin

g to

bio

Mér

ieu

x, o

r o

ne

of i

ts s

ub

sid

iari

es, o

r o

ne

of i

ts c

om

pan

ies

· PR

N 9

315

05

1 0

06

GB

A