emergency stop buttons - steven engineering › tech_support › pdfs › 04_main...• rugged...

42
750 SAFETY LIGHT SCREENS CONTROLLERS & MODULES EMERGENCY STOP & STOP CONTROL Emergency Stop Buttons Push-to-stop/twist-to-release Emergency Stop palm buttons are available in panel-mount or remotely located IP65 enclosures. Illuminated models help operators quickly identify actuated buttons, allowing for a quick return to normal operations. Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Upload: others

Post on 23-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

750

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Emergency Stop ButtonsPush-to-stop/twist-to-release Emergency Stop palm buttons are available in panel-mount or remotely located IP65 enclosures. Illuminated models help operators quickly identify actuated buttons, allowing for a quick return to normal operations.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 2: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

751More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Series Description Options MountingDimensionsH x W x D

ProtectionRating

Easy to install 30 mm mount. page 752

Non-IlluminatedIlluminated 30 mm 119.8 x ø 80 mm IP65

Flat mount with wide variety of options. page 753

Non-IlluminatedIlluminatedNon-Illuminated LockingIlluminated Locking

Flat mount 102.1 x 80.8 x 80.3 mm IP65

Panel mount E-Stop buttons.page 764

Non-IlluminatedIlluminatedLockingIlluminated Locking

Panel Varies by model IP65

Mechanical E-Stop button kits.page 768

High currentMetal shaft Panel or flat 106 x 70 x 70 mm IP65

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 3: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

752

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Illuminated Base-mount E-Stop Push-Buttons

Description Illumination*** Models

2NC / 1NO (PNP) YEL/RED-Flash/Solid SSA-EB1PLYR-12ECQ8

2NC / 1NO (PNP) GREEN/RED-Flash/Solid SSA-EB1PLGR-12ECQ8

2NC / 1NO (PNP) OFF/RED-Flash/Solid SSA-EB1PLXR-12ECQ8

2NC / 1NO (PNP) OFF/RED-Flash/Solid, with 60 mm button SSA-EB2PLXR-12ECQ8 NEW

2NC / 1NO (PNP) OFF/RED-Solid/Solid SSA-EB1PL-12ECQ8

2NC – Safety BUS node compatible* YEL/RED-Flash SSA-EB1PLYR-02ECQ5A

2NC – Safety BUS node compatible* OFF/RED-Flash SSA-EB1PLXR-02ECQ5A

2NC – Safety BUS node compatible* OFF/RED-Soild SSA-EB1PL-02ECQ5A

2NC – Safety BUS node compatible* Illuminated button, OFF (armed), RED (solid, PUSH ON) SSA-EB1PL2-02ECQ5A NEW

2NC – Safety BUS node compatible** YEL/RED-Flash SSA-EB1PLYR-02ECQ5B

2NC – Safety BUS node compatible** OFF/RED-Flash SSA-EB1PLXR-02ECQ5B

2NC – Safety BUS node compatible** OFF/RED-Solid SSA-EB1PL-02ECQ5B

2NC – Safety BUS node compatible** Illuminated button, OFF (armed)RED (solid, PUSH ON) SSA-EB1PL2-02ECQ5B NEW

E-Stop ButtonsIlluminated 30 mm MountIllumination allows for easy identification of which E-stop has been activated.

• Easy installation and no assembly or individual wiring required• Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5• Compliant with ANSI B11.19, ANSI NFPA79 and

IEC/EN 60204-1 Emergency Stop requirements• Incorporate with OTB/STB optical touch button for a simplified operator

station that does not require an additional enclosure.• “Safe Break Action” ensures NC contacts will open if the contact block is

damaged or separated from the actuator• Models designed to interface with Safety BUS nodes/gateways

For more specifications see page 761.

Connection options: A model with a QD requires a mating cordset (see page 758).

* CH1=pins 1 & 2, CH2=pins 4 & 5, 5-pin M12 QD ** CH1=pins 1 & 4, CH2=pins 2 & 5, 5-pin M12 QD*** For EZ-LIGHT Illumination logic see page 759.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 4: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

753More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop Buttons Illuminated Flush MountIllumination allows for easy identification of which E-stop has been activated.

• Easy installation with no assembly or individual wiring required• Remotely located E-Stop buttons can be positioned to be clearly identified,

clearly visible and readily accessible• Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5• Compliant with ANSI B11.19, ANSI NFPA79 and IEC/EN 60204-1 Emergency

Stop requirements• “Safe Break Action” ensures NC contacts will open if the contact block is

damaged or separated from the actuator• Models designed to interface with Safety BUS nodes/gateways

Illuminated Flush-mount E-Stop Push-Buttons

Description Illumination*** Models

2NC / 1NO (PNP) YEL/RED-Flash/Solid SSA-EB1PLYR-12ED1Q8

2NC / 1NO (PNP) YEL/RED-Flash/Solid, 1/2” NPT conduit connection with terminal strip SSA-EB1PLYR-12ED1 NEW

2NC / 1NO (PNP) GREEN/RED-Flash/Solid SSA-EB1PLGR-12ED1Q8

2NC / 1NO (PNP) GREEN/RED-Flash/Solid, 1/2” NPT conduit connection with terminal strip SSA-EB1PLGR-12ED1 NEW

2NC / 1NO (PNP) OFF/RED-Flash/Solid SSA-EB1PLXR-12ED1Q8

2NC / 1NO (PNP) OFF/RED-Flash/Solid, with 60 mm button SSA-EB2PLXR-12ED1Q8 NEW

2NC / 1NO (PNP) OFF/RED-Flash/Solid, 1/2” NPT conduit connection with terminal strip SSA-EB1PLXR-12ED1 NEW

2NC / 1NO (PNP) OFF/RED-Solid/Solid SSA-EB1PL-12ED1Q8

2NC – Safety BUS node compatible* YEL/RED-Flash SSA-EB1PLYR-02ED1Q5A

2NC – Safety BUS node compatible* OFF/RED-Flash SSA-EB1PLXR-02ED1Q5A

2NC – Safety BUS node compatible* OFF/RED-Solid SSA-EB1PL-02ED1Q5A

2NC – Safety BUS node compatible** YEL/RED-Flash SSA-EB1PLYR-02ED1Q5B

2NC – Safety BUS node compatible** OFF/RED-Flash SSA-EB1PLXR-02ED1Q5B

2NC – Safety BUS node compatible** OFF/RED-Solid SSA-EB1PL-02ED1Q5B

For more specifications see page 761.

Connection options: A model with a QD requires a mating cordset (see page 758).

* CH1=pins 1 & 2, CH2=pins 4 & 5, 5-pin M12 QD ** CH1=pins 1 & 4, CH2=pins 2 & 5, 5-pin M12 QD***** For EZ-LIGHT Illumination logic see page 759.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 5: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

754

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Base-mount E-Stop Push-Buttons

Description Models

2NC SSA-EB1P-02ECQ4

1NC / 1NO SSA-EB1P-11ECQ4

2NC – Safety BUS node compatible* SSA-EB1P-02ECQ5A

2NC – Safety BUS node compatible with 60 mm button* SSA-EB2P-02ECQ5A NEW

2NC – Safety BUS node compatible** SSA-EB1P-02ECQ5B

2NC – Safety BUS node compatible with 60 mm button** SSA-EB2P-02ECQ5B NEW

2NC / 2NO SSA-EB1P-22ECQ8

4NC with 60 mm button SSA-EB2P-04ECQ8 NEW

E-Stop Buttons30 mm MountThe 30 mm Mount E-Stop Buttons allow for easy installation with no assembly or individual wiring required.

• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5• Compliant with ANSI B11.19, ANSI NFPA79 and IEC/EN 60204-1 Emergency

Stop requirements• “Safe Break Action” ensures NC contacts will open if the contact block is

damaged or separated from the actuator• Models designed to interface with Safety BUS nodes/gateways

For more specifications see page 761.

Connection options: A model with a QD requires a mating cordset (see page 758).

* CH1=pins 1 & 2, CH2=pins 4 & 5, 5-pin M12 QD ** CH1=pins 1 & 4, CH2=pins 2 & 5, 5-pin M12 QD

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 6: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

755More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Flush-mount E-Stop Push-Button

Description Standard Models

2NC SSA-EB1P-02ED1Q4

2NC - Alternate pinout SSA-EB1P-02ED1Q4A NEW

1NC/1NO SSA-EB1P-11ED1Q4

2NC, Safety BUS node compatible* SSA-EB1P-02ED1Q5A

2NC, Safety BUS node compatible with 60 mm button* SSA-EB2P-02ED1Q4A NEW

2NC, Safety BUS node compatible** SSA-EB1P-02ED1Q5B

2NC, Safety BUS node compatible with 60 mm button** SSA-EB2P-02ED1Q4B NEW

2NC/2NO SSA-EB1P-22ED1Q8

4NC with 60 mm button SSA-EB2P-04ED1Q8 NEW

2NC/1NO, Illuminated button—Push ON RED SSA-EB1PL2-12ED1Q8

E-Stop ButtonsFlush MountFlush Mount E-Stop Buttons are easy to install with no assembly or individual wiring required.

• Models designed to interface with Safety BUS nodes/gateways• Rugged design• Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5• Compliant with ANSI B11.19, ANSI NFPA79 and IEC/EN 60204-1 Emergency

Stop requirements• “Safe Break Action” ensures NC contacts will open if the contact block is

damaged or separated from the actuator

For more specifications see page 761.

Connection options: A model with a QD requires a mating cordset (see page 758).

* CH1=pins 1 & 2, CH2=pins 4 & 5, 5-pin M12 QD ** CH1=pins 1 & 4, CH2=pins 2 & 5, 5-pin M12 QD

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 7: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

756

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Lockable E-Stop ButtonsIlluminated Flush MountIlluminated Flush Mount Lockable E-Stop Buttons are easy to install and have a locking capability.

• Push-to-stop, twist-to-release operation per IEC 60947-5-5• Compliant with ANSI B11.19, ANSI NFPA79 and IEC/EN 60204-1 Emergency

Stop requirements• “Safe Break Action” ensures NC contacts will open if the contact block is

damaged or separated from the actuator• Models designed to interface with Safety BUS nodes/gateways• Rugged design is easy to install with no assembly or individual wiring required

Lockable Illuminated Flush-mount E-Stop Push-Buttons

Description Illumination* Models

2NC / 1NO (PNP) YEL/RED-Flash/Solid SSA-EB1MLYRP-12ED1Q8

2NC / 1NO (PNP)YEL/RED-Flash/Solid, 1/2” NPT conduit connection with terminal strip

SSA-EB1MLYRP-12ED1Q8 NEW

2NC / 1NO (PNP) GREEN/RED-Flash/Solid SSA-EB1MLGRP-12ED1Q8

2NC / 1NO (PNP)GREEN/RED-Flash/Solid, 1/2” NPT conduit connection with terminal strip

SSA-EB1MLGRP-12ED1 NEW

2NC / 1NO (PNP) OFF/RED-Flash/Solid SSA-EB1MLXRP-12ED1Q8

2NC / 1NO (PNP)OFF/RED-Flash/Solid, 1/2” NPT conduit connection with terminal strip

SSA-EB1MLXRP-12ED1 NEW

2NC / 1NO (PNP) OFF/RED-Solid/Solid SSA-EB1MLP-12ED1Q8

For more specifications see page 762.

Connection options: A model with a QD requires a mating cordset (see page 758).

* For EZ-LIGHT Illumination logic see page 759.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 8: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

757More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Lockable Flush-mount E-Stop Push-Button

Description Models

2NC SSA-EB1MP-02ED1Q4

2NC - Alternate pinout SSA-EB1MP-02ED1Q4A NEW

1NC/1NO SSA-EB1MP-11ED1Q4

2NC, Safety BUS node compatible* SSA-EB1MP-02ED1Q5A

2NC, Safety BUS node compatible** SSA-EB1MP-02ED1Q5B

2NC/2NO SSA-EB1MP-22ED1Q8

2NC/1NO, Illuminated button—Push ON RED SSA-EB1ML2P-12ED1Q8

Lockable E-Stop ButtonsFlush MountFlush Mount Lockable E-Stop Buttons are easy to install and have a locking capability.

• Push-to-stop, twist-to-release operation per IEC 60947-5-5• Compliant with ANSI B11.19, ANSI NFPA79 and IEC/EN 60204-1 Emergency Stop

requirements• “Safe Break Action” ensures NC contacts will open if the contact block is damaged

or separated from the actuator• Models designed to interface with Safety BUS nodes/gateways• Rugged design is easy to install with no assembly or individual wiring required

For more specifications see page 762.

Connection options: A model with a QD requires a mating cordset (see page 758).

* CH1=pins 1 & 2, CH2=pins 4 & 5, 5-pin M12 QD ** CH1=pins 1 & 4, CH2=pins 2 & 5, 5-pin M12 QD

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 9: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

758

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Cordsets

Euro QD C(for Q4 and Q8 models)

See page page 906

Length

Threaded 4-Pin Threaded 8-Pin

Straight

1.83 m MQDC-406 MQDC2S-806

4.57 m MQDC-415 MQDC2S-815

9.14 m MQDC-430 MQDC2S-830

15.2 m MQDC-450 MQDC2S-850

Euro QD–Double-Ended B(for Q5 and Q8 models)

See page 912

Length 5-Pin 8-Pin

0.31 m DEE2R-51D DEE2R-81D

0.91 m DEE2R-53D DEE2R-83D

2.44 m DEE2R-58D DEE2R-88D

4.57 m DEE2R-515D DEE2R-815D

7.62 m DEE2R-525D DEE2R-825D

15.2 m DEE2R-550D DEE2R-850D

22.9 m DEE2R-575D DEE2R-875D

30.5 m DEE2R-5100D DEE2R-8100D

Series Hookup Cordset SolutionThis interconnection solution allows for quick hookup of a series string of emergency stop buttons. For the CSS models (A) Branch #1 and Branch #2 are 300 mm (12”) in length and the length of the trunk is listed below. See “Cordsets” below and specific model E-Stop datasheet for compete information, including installation instructions, hookup, and accessories.

(A)(B) (A) (C)

Euro QD Splitter A (for Q4 and Q8 models)

Length 4-Pin

0.31 m CSS-M12F41M12M41M12F41

0.91 m CSS-M12F43M12M41M12F41

2.44 m CSS-M12F48M12M41M12F41

8-Pin

0.31 m CSS-M12F81M12M81M12F81

0.91 m CSS-M12F83M12M81M12F81

2.44 m CSS-M12F88M12M81M12F81

Brackets30 mm Mount

See page 860 See page 860 See page 861

SSA-MBK-EEC1 SSA-MBK-EEC2 SSA-MBK-EEC3

Additional brackets and information available.See page 852

Additional cordset information available.See page 902.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 10: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

759More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop Legend Labels (adhesive backed label)

Product Description Language Inscription Models†

60 mm diameter (OD) Emergency Stop Legend with inscription and ISO 13850 Emergency Stop symbol (adhesive backed label).

41 mm hole for application around the base of SSA-EB1(2)P… (Pack of 10 each)

English EMERGENCY STOP ESL-41/60-10

English & Spanish PARADA DE EMERGENCIA ESL-41/60-ENES-10

Spanish PARADA DE EMERGENCIA ESL-41/60-ES-10

German NOT-AUS ESL-41/60-DE-10

French ARRÊT D'URGENCE ESL-41/60-FR-10

Italian EMERGENZA ARRESTO ESL-41/60-IT-10

Russian АВАРИЙНЫЙ ОСТАНОВ ESL-41/60-RU-10

Japanese 非常停止 ESL-41/60-JA-10

Simplified Chinese (Mainland China) 紧急停止 ESL-41/60-CN-10

Traditional Chinese (Taiwan) 緊急停止 ESL-41/60-TW-10

Portuguese PARADA DE EMERGÊNCIA ESL-41/60-PT-10

70 mm diameter (OD) Emergency Stop Legend with inscription and ISO 13850 Emergency Stop symbol (adhesive backed label).

44 mm hole for application around SSA-EB1M… (Pack of 10 each).

English EMERGENCY STOP ESL-44/70-10

English & Spanish PARADA DE EMERGENCIA ESL-44/70-ENES-10

Spanish PARADA DE EMERGENCIA ESL-44/70-ES-10

German NOT-AUS ESL-44/70-DE-10

French ARRÊT D'URGENCE ESL-44/70-FR-10

Italian EMERGENZA ARRESTO ESL-44/70-IT-10

Russian АВАРИЙНЫЙ ОСТАНОВ ESL-44/70-RU-10

Japanese 非常停止 ESL-44/70-JA-10

Simplified Chinese (Mainland China) 紧急停止 ESL-44/70-CN-10

Traditional Chinese (Taiwan) 緊急停止 ESL-44/70-TW-10

Portuguese PARADA DE EMERGÊNCIA ESL-44/70-PT-10

EZ-LIGHT™ Illumination Logic for Emergency Stop buttons

Situation Indication Illumination Logic

SSA-EB1xxLYR-xxxxQx or SSA-EB1xxLGR-xxxxQx

Button ArmedPin 3 open

YELLOW / SOLID or GREEN / SOLID

• Indicates button is armed• If used, ES-FA-11AA Module is in a RESET/RUN condition (31/32 open)

Button Pushed Pin3 open or +V dc

RED / FLASH• Indicates the button that is pushed (actuated)• Signal on Pin 3 has no effect on a button that has been pushed (actuated)

Button ArmedPin 3 = +V dc

RED / SOLID• Indicates the machine is in an Emergency Stop or other stop condition, but that specific button has not been pushed (actuated)• This optional signal (12 to 30 V dc) allows the user to indicate a stop condition by turning the armed indication to a RED (steady) Indication

SSA-EB1xxLXR-xxxxQx

Button ArmedPin 3 open

OFF• Indicates button is armed• If used, ES-FA-11AA Module is in a RESET/RUN condition (31/32 open)

Button PushedPin 3 open or +V dc

RED / FLASH• Indicates the button that is pushed (actuated)• Signal on Pin 3 has no effect on a button that has been pushed (actuated)

Button ArmedPin 3 = +V dc

RED / SOLID• Indicates the machine is in an Emergency Stop or other stop condition, but that specific button has not been pushed (actuated)• This optional signal (12 to 30 V dc) allows the user to indicate a stop condition by turning the armed indication to a RED (steady) Indication

SSA-EB1xxL-xxxxQx

Button ArmedPin 3 open

OFF• Indicates button is armed• If used, ES-FA-11AA Module is in a RESET/RUN condition (31/32 open)

Button Pushed Pin 3 open or +V dc

RED / SOLID• Indicates the button that is pushed (actuated)• Signal on Pin 3 has no effect on a button that has been pushed (actuated)

Button ArmedPin 3 = +V dc

RED / SOLID• Indicates the machine is in an Emergency Stop or other stop condition, but that specific button has not been pushed (actuated)• This optional signal (12 to 30 V dc) allows the user to indicate a stop condition by turning the armed indication to a RED (steady) Indication

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 11: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

760

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Illuminated models

ø 80 mm

119.8 mm

80.8 mm80.3 mm

102.1 mm

80.8 mm80.3 mm

111.9 mm

Non-Illuminated models

Non-Illuminated models

Non-Illuminated models

Illuminated models

Illuminated models

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 12: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

761More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

30 mm E-Stop Push Button SpecificationsHousing / Button Mounting Polycarbonate / Polyamide

Threaded base has M30 x 1.5 external threads.(M30 hardware included)Max. Tightening Torque: 0.56 N·m (5 in·lbf)

Operating Temperature –25 to +55°C

Environmental rating IP65 (IEC60529)

Operating Humidity 45% to 85% RH (no condensation)

Insulation Resistance 100M minimum (500 V dc megger)

Impulse Withstand Voltage 2.5 kV

Pollution Degree 3

Overvoltage Category II

Contact material / bounce* Gold plated silver / 20 ms

Electrical Life 100,000 operations minimum, 250,000 operations minimum at 24 V ac/dc, 100 mA

Mechanical Life 250,000 operations

B10d 100,000 (based on ISO13849-1(2006))

Shock & Vibration Resistance Operating extremes: 150m/s2 (15G) Operating extremes: 10 to 500 Hz, amplitude 0.35 mm acceleration 50 m/s2

LED Illumination Color: Yellow - 590 nm, Red - 618 nm, Green - 525 nm; Flash Rate: 1.6 Hz at 50% duty cycle; Voltage/Current: 12 – 30 V dc; 120 mA at 12 V dc, 65 mA at 24 Vdc, 60 mA at 30 V dc, SSA-EB1..LGR-.. (GREEN) only: 12 – 30 V dc; 135 mA @ 12 V dc, 75 mA @ 24 V dc, 70 mA @ 30 V dc

Electrical Rating Minimum load: 1 mA @ 5 V ac/dc SSA-EB1xx-..Q5A/Q5B: 3A @ 250 V maximum SSA-EB1xx-xxED1Q8: 2A at 60 V ac/75 V dc maximumUL Applications (UL/cUL): 1.5A @ 250 V ac, 1A @ 30 V dc (pilot duty) CE Applications: AC-15: 1.5A @ 250 V ac, DC-13: 1A @ 30 V dc

Rated Insulation Voltage (Ui) 250 V

Rated Current (Ith) 3A

Rated Operating Voltage (Ue) See Electrical Rating 30 V 60 V ac/75 V dc 125 V 250 V

Rated Operating Current SSA-EB1xxLxx-02ED1Q5A/Q5B

Safety Contact (NC)

AC 50/60 HzResistive Load (AC-12) — — — 3A

Inductive Load (AC-15) — — 3A 1.5A

DCResistive Load (DC-12) 2A — 0.4A 0.2A

Inductive Load (DC-13) 1A — 0.22A 0.1A

Monitor Contacts (NO)

AC 50/60 HzResistive Load (AC-12) — — 1.2A 0.6A

Inductive Load (AC-15) — — 0.6A 0.3A

DCResistive Load (DC-12) 2A — 0.4A 0.2A

Inductive Load (DC-13) 1A — 0.22A 0.1A

SSA-EB1PLxx-02ECQ5A/Q5B (illuminated)

Safety Contact (NC)

AC 50/60 HzResistive Load (AC-12) — — — 3A

Inductive Load (AC-15) — — 3A 1.5A

DCResistive Load (DC-12) 2A — 0.4A 0.2A

Inductive Load (DC-13) 1A — 0.22A 0.1A

SSA-EB1Pxx-xxECQ8 See above for SSA-EB1P-22ECQ8 Monitor Contacts

Safety Contact (NC)

AC 50/60 HzResistive Load (AC-12) — 2A — —

Inductive Load (AC-15) — 2A — —

DCResistive Load (DC-12) 2A 0.4A — —

Inductive Load (DC-13) 1A 0.22A — —

Auxiliary Output (NO)12 to 30 V dc (from pin 2)

Resistive Load (DC-12) 0.25A — — —

Inductive Load (DC-13) 0.25A — — —

• The rated operating currents are measured at resistive/inductive load types specified in IEC 60947-5-1.• See “Electrical Rating” above for maximum voltage/current rating per model.

Design Standards Compliant with EN/IEC 60497-1 / -5-1, ISO 13850, ANSI B11.19 , ANSI NFPA79, IEC 60204-1

Certifications

E-stop button: (pending)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 13: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

762

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Lockable and Illuminated E-Stop Push-Button SpecificationsHousing / Button Mounting Polycarbonate / Polyamide

#10 or M5 (M5 hardware included), Max. Tightening Torque: 0.56 N•m (5 in•lbf)

Operating Temperature –25 to +55°C

Environmental rating IP65 (IEC60529)

Operating Humidity 45% to 85% RH (no condensation)

Insulation Resistance 100MΩ minimum (500 V dc megger)

Impulse Withstand Voltage 2.5kV

Pollution Degree 3

Overvoltage Category II

Contact material / bounce Gold plated silver / 20ms

Electrical Life 100,000 operations minimum, 250,000 operations minimum at 24 V ac/dc, 100 mA

Mechanical Life 250,000 operations,

B10d 100,000 (based on ISO13849-1(2006))

Total Weight of Padlock and Hasp (SSA-EB1M..P-.. only)

1500g (3.3 lb) maximum

Since various form and sizes are available, ensure applicability of padlock and hasp before use. If total weight exceeds 1500g, the switch may malfunction or fail.

Padlock size

a b c d

7 mm max 19 mm min 39 mm min 15 mm min

d

b

a c Dimension “d” is 6 mm or more when attaching a padllock from the side of a switch.

Shock Resistance Operating extremes: 150m/s2 (15G)

Vibration Resistance Operating extremes: 10 to 500 Hz, amplitude 0.35 mm acceleration 50 m/s2

LED Illumination Color: Yellow - 590 nm, Red - 618 nm, Green - 525 nmFlash Rate: 1.6 Hz @ 50% duty cycleVoltage/Current: 12 – 30 V dc; 120 mA @ 12 V dc, 65 mA @ 24 V dc, 60 mA @ 30 V dc,

SSA-EB1..LGR-..(GREEN) only: 12 - 30 V dc; 135 mA @ 12 V dc, 75 mA @ 24 V dc, 70 mA @ 30 V dc

Electrical Rating Minimum load: 1 mA @ 5 V ac/dcSSA-EB1xx-..Q5A/Q5B: 3A @ 250 V maximumSSA-EB1xx-xxED1Q8: 2A @ 60 V ac/75 V dc maximumUL Applications (UL/cUL): 1.5A @ 250 V ac, 1A @ 30 V dc (pilot duty) CE Applications: AC-15: 1.5A @ 250 V ac, DC-13: 1A @ 30 V dc

Rated Insulation Voltage (Ui) 250 V

Rated Current (Ith) 3A

Rated Operating Voltage (Ue) See Electrical Rating 30 V 60 V ac/75 V dc 125 V 250 V

Rated Operating Current SSA-EB1xxLxx-02ED1Q5A/Q5B

Safety Contact (NC)

AC 50/60 HzResistive Load (AC-12) — — — 3A

Inductive Load (AC-15) — — 3A 1.5A

DCResistive Load (DC-12) 2A — 0.4A 0.2A

Inductive Load (DC-13) 1A — 0.22A 0.1A

SSA-EB1xx-xxED1Q8

Safety Contact (NC)

AC 50/60 HzResistive Load (AC-12) — 2A — —

Inductive Load (AC-15) — 2A — —

DCResistive Load (DC-12) 2A 0.4A — —

Inductive Load (DC-13) 1A 0.22A — —

Auxiliary Output (NO)

12 to 30 V dc (from pin 2)

Resistive Load (DC-12) 0.25A — — —

Inductive Load (DC-13) 0.25A — — —

• The rated operating currents are measured at resistive/inductive load types specified in IEC 60947-5-1. • See “Electrical Rating” above for maximum voltage/current rating per model.

Design Standards Compliant with EN/IEC 60497-1 / -5-1, ISO 13850, ANSI B11.19 , ANSI NFPA79, IEC 60204-1

Certifications

E-stop button: (pending) (pending)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 14: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

763More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Lockable E-Stop Push-Button SpecificationsHousing / Button Mounting Polycarbonate / Polyamide

#10 or M5 (M5 hardware included), Max. Tightening Torque: 0.56 N•m (5 in•lbf)

Operating Temperature –25 to +55°C

Environmental rating IP65 (IEC60529)

Operating Humidity 45% to 85% RH (no condensation)

Insulation Resistance 100MΩ minimum (500 V dc megger)

Impulse Withstand Voltage 2.5kV

Pollution Degree 3

Overvoltage Category II

Contact material / bounce Gold plated silver / 20 ms

Electrical Life 100,000 operations minimum, 250,000 operations minimum at 24 V ac/dc, 100 mA

Mechanical Life 250,000 operations,

B10d 100,000 (based on ISO13849-1(2006))

Total Weight of Padlock and Hasp (SSA-EB1M..P-.. only)

1500g (3.3 lb) maximum

Since various form and sizes are available, ensure applicability of padlock and hasp before use. If total weight exceeds 1500g, the switch may malfunction or fail.

Padlock size

a b c d

7 mm max 19 mm min 39 mm min 15 mm min

d

b

a c Dimension “d” is 6 mm or more when attaching a padllock from the side of a switch.

Shock Resistance Operating extremes: 150m/s2 (15G)

Vibration Resistance Operating extremes: 10 to 500 Hz, amplitude 0.35mm acceleration 50m/s2

LED Voltage/Current 24 V ac/dc ±10%, 15mA @ 24 V ac/dc (SSA-EB1PL2-12ED1Q8 only)

Electrical Rating Minimum load: 1 mA @ 5 V ac/dcSSA-EB1xx-..Q4 and -..Q5: 3A @ 250 V maximumSSA-EB1xx-..Q8: 2A @ 60 V AC/75 V DC maximumUL Applications (UL/cUL): 1.5A @ 250 V ac, 1A @ 30 V dc (pilot duty) CE Applications: AC-15: 1.5A @ 250 V ac, DC-13: 1A @ 30 V dc

Rated Insulation Voltage (Ui) 250 V

Rated Current (Ith) 3A

Rated Operating Voltage (Ue) See Electrical Rating 30 V 125 V 250 V

Rated Operating Current Safety Contact (NC) AC 50/60 Hz

Resistive Load (AC-12) - - 3A

Inductive Load (AC-15) - 3A 1.5A

DCResistive Load (DC-12) 2A 0.4A 0.2A

Inductive Load (DC-13) 1A 0.22A 0.1A

Monitor Contacts (NO) AC 50/60 Hz

Resistive Load (AC-12) - 1.2A 0.6A

Inductive Load (AC-14) - 0.6A 0.3A

DCResistive Load (DC-12) 2A 0.4A 0.2A

Inductive Load (DC-13) 1A 0.22A 0.1A

• The rated operating currents are measured at resistive/inductive load types specified in IEC 60947-5-1. • See “Electrical Rating” above for maximum voltage/current rating per model.

Design Standards Compliant with EN/IEC 60497-1 / -5-1, ISO 13850, ANSI B11.19 , ANSI NFPA79, IEC 60204-1

Certifications

E-stop button: (pending) (pending)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 15: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

764

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop Buttons 30 mm Panel MountEasy to install with locking and illuminated models available.

• Up to four contacts; various configurations available• Push-to-stop, twist-to-release (standard and lockable), or

pull-to-release (standard) operation per IEC60947-5-5• Latching design complies with ISO 13850; direct (positive) opening

operation per IEC 60947-5-1• Compliant with ANSI B11.19, ANSI NFPA79, and IEC/EN 60204-1

Emergency Stop requirements• “Safe Break Action” ensures N.C. contacts will open if the contact block

is separated from the actuator

Panel Mount E-Stop Push-Buttons

Description Models 40 mm Button Models 60 mm Button

2NC SSA-EB1P-02 SSA-EB2P-02

4NC SSA-EB1P-04 SSA-EB2P-04

1NC / 1NO SSA-EB1P-11 SSA-EB2P-11

3NC / 1NO SSA-EB1P-13 SSA-EB2P-13

2NC / 2NO SSA-EB1P-22 SSA-EB2P-22

Lockable Panel Mount E-Stop Push-Buttons

Description Models 44 mm Button

2NC SSA-EB1MP-02

4NC SSA-EB1MP-04

1NC / 1NO SSA-EB1MP-11

3NC / 1NO SSA-EB1MP-13

2NC / 2NO SSA-EB1MP-22

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 16: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

765More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Illuminated E-Stop Buttons 30 mm Panel MountEasy to install with locking and illuminated models available.

• Up to four contacts; various configurations available• Push-to-stop, twist-to-release (standard and lockable), or

pull-to-release (standard) operation per IEC60947-5-5• Latching design complies with ISO 13850;

direct (positive) opening operation per IEC 60947-5-1• Compliant with ANSI B11.19, ANSI NFPA79, and

IEC/EN 60204-1 Emergency Stop requirements• “Safe Break Action” ensures N.C. contacts will open if

the contact block is separated from the actuator

Illuminated Panel Mount E-Stop Push-Buttons

Description Models 40 mm Button

2NC, LED function per hookup SSA-EB1PL1-02

4NC, LED function per hookup SSA-EB1PL1-04

1NC / 1NO, LED function per hookup SSA-EB1PL1-11

3NC / 1NO, LED function per hookup SSA-EB1PL1-13

2NC / 2NO, LED function per hookup SSA-EB1PL1-22

2NC / 1NO, LED function PRESS ON SSA-EB1PL2-12

Illuminated Lockable Panel Mount E-Stop Push-Buttons

Description Models 44 mm Button

2NC, LED function per hookup SSA-EB1ML1P-02

4NC, LED function per hookup SSA-EB1ML1P-04

1NC / 1NO, LED function per hookup SSA-EB1ML1P-11

3NC / 1NO, LED function per hookup SSA-EB1ML1P-13

2NC / 2NO, LED function per hookup SSA-EB1ML1P-22

2NC / 1NO, LED function PRESS ON SSA-EB1ML2P-12

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 17: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

766

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop Legend Labels (adhesive backed label)

Product Description Language Inscription Models†

60 mm diameter (OD) Emergency Stop Legend with inscription and ISO 13850 Emergency Stop symbol (adhesive backed label).

41 mm hole for application around the base of SSA-EB1(2)P… (Pack of 10 each)

English EMERGENCY STOP ESL-41/60-10

English & Spanish PARADA DE EMERGENCIA ESL-41/60-ENES-10

Spanish PARADA DE EMERGENCIA ESL-41/60-ES-10

German NOT-AUS ESL-41/60-DE-10

French ARRÊT D'URGENCE ESL-41/60-FR-10

Italian EMERGENZA ARRESTO ESL-41/60-IT-10

Russian АВАРИЙНЫЙ ОСТАНОВ ESL-41/60-RU-10

Japanese 非常停止 ESL-41/60-JA-10

Simplified Chinese (Mainland China) 紧急停止 ESL-41/60-CN-10

Traditional Chinese (Taiwan) 緊急停止 ESL-41/60-TW-10

Portuguese PARADA DE EMERGÊNCIA ESL-41/60-PT-10

70 mm diameter (OD) Emergency Stop Legend with inscription and ISO 13850 Emergency Stop symbol (adhesive backed label).

44 mm hole for application around SSA-EB1M… (Pack of 10 each).

English EMERGENCY STOP ESL-44/70-10

English & Spanish PARADA DE EMERGENCIA ESL-44/70-ENES-10

Spanish PARADA DE EMERGENCIA ESL-44/70-ES-10

German NOT-AUS ESL-44/70-DE-10

French ARRÊT D'URGENCE ESL-44/70-FR-10

Italian EMERGENZA ARRESTO ESL-44/70-IT-10

Russian АВАРИЙНЫЙ ОСТАНОВ ESL-44/70-RU-10

Japanese 非常停止 ESL-44/70-JA-10

Simplified Chinese (Mainland China) 紧急停止 ESL-44/70-CN-10

Traditional Chinese (Taiwan) 緊急停止 ESL-44/70-TW-10

Portuguese PARADA DE EMERGÊNCIA ESL-44/70-PT-10

60 mm diameter (OD) Emergency Stop Legend with or without inscription (plastic with seal).

30 mm hole for application with SSA-EB1(2)P… or SSA-EB1M… (1 each)

English EMERGENCY STOP ESLP1-30/60

N.A. (Blank) ESLP1-30/60-NW

IP20 Finger-safe terminal cove SSA-EB1-FSTC

Standard terminal cover (supplied) SSA-EB1-TC

Jam nut wrench SSA-EB1-LRW

Jam nut twist wrench SSA-EB1-LRTW

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 18: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

767More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop Push Button SpecificationsButton/Locking Collar Polyamide/Aluminum

Operating Temperature Non-illuminated: –25 to +60°CIlluminated: –25 to +55°C

Environmental rating IP65 (IEC60529)

Operating Humidity 45% to 85% RH (no condensation)

Insulation Resistance 100M minimum (500 V dc megger)

Impulse Withstand Voltage 2.5kV

Pollution Degree 3

Overvoltage Category II

Contact material / bounce* Gold plated silver / 20 ms

Electrical Life 100,000 operations minimum, 250,000 operations minimum at 24 V ac/dc, 100 mA

Mechanical Life 250,000 operations

B10d 100,000 (based on ISO13849-1(2006))

Shock & Vibration Resistance Shock Operating extremes: 150m/s2 (15G) Vibration Operating extremes: 10 to 500 Hz, amplitude 0.35 mm acceleration 50 m/s2

Electrical Rating Minimum load: 1 mA @ 5 V ac/dc UL Applications: 1.5A @ 250 V ac, 1A @ 30 V dc (pilot duty) CE Applications: AC-15: 1.5A @ 250 V ac, DC-13: 1A @ 30 V dc

Rated Insulation Voltage (Ui) 250 V

Rated Current (Ith) 3A

Rated Operating Current Safety Contact (NC) 30 V 125 V 250 V

AC 50/60 HzResistive Load (AC-12) — — —

Inductive Load (AC-15) — — 3A

DCResistive Load (DC-12) 2A — 0.4A

Inductive Load (DC-13) 1A — 0.22A

Monitor Contact (NO) 30 V 125 V 250 V

AC 50/60 HzResistive Load (AC-12) — 1.2A 0.6A

Inductive Load (AC-15) — 0.6A 0.3A

DCResistive Load (DC-12) 2A 0.4A 0.2A

Inductive Load (DC-13) 1A 0.22A 0.1A

The operating current is classified according to JIS C 8201-5-1-1999 making and breaking capacities and are measured at resistive/inductive load types specified in IEC 60947-5-1. See “Electrical Rating” above for specific model and UL/CE maximum ratings.

Design Standards Compliant with EN/IEC 60497-1 / -5-1, ISO 13850, ANSI B11.19 , ANSI NFPA79, IEC 60204-1

Certifications

ø 60 mm

80.7 mm

37 mm

ø 40 mm

37 mm

80.7 mm

ø 44 mm

37 mm

104.2 mm

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 19: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

768

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop ButtonsEmergency Stop Push ButtonsE-Stop button solution available as individual components or as kits for easy ordering.

• Higher current rating• Modular design makes assembly and installation easy for either

panel-mount or enclosure mounting• Push-to-stop, twist-to-release operation per IEC 60497-5-5• Compliant with ANSI B11.19, ANSI NFPA79, and IEC/EN 60204-1

Emergency Stop requirements• Panel mount through 22 mm mounting hole

E-Stop Push-Button Panel Mount Kits

E-Stop Button Contacts Legend Enclosure Models

Metal-base

2 NC

Yes No

SSA-EBM-02L

1 NC & 1 NO SSA-EBM-11L

2 NC & 1 NO SSA-EBM-12L

NC= Normally closed contact, NO= Normally open contact* The LPZP1A5 enclosure has replaced 8-L2PP-1A5 (discontinued). Please note changes in size (8-L2PP-1A5: 72mm x 85mm) and mounting hole location (8-L2PP-1A5: 49mm x 54mm).

E-Stop Push-Button Enclosure Kits

E-Stop Button Contacts Legend Enclosure Models*

Metal

2 NC

Yes Yes

SSA-EBM-02E

1 NC & 1 NO SSA-EBM-11E

2 NC & 1 NO SSA-EBM-12E

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 20: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

769More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop Push-Button Components

Product Description Models

22.5 mm metal button (8-LM2T-AU120 mounting adapter sold separately) 8-LM2T-B6644*

Metal mounting adapter (for metal button) 8-LM2T-AU120

Normally closed (NC) positively driven contact element 8-LM2T-C01**

Normally open (NO) auxiliary contact element 8-LM2T-C10

One 22 mm button enclosure, maximum of three contact blocks, wire entry through three sides (M16, M20 or M25) or the bottom (M16)

LPZP1A5***

* Twist to release, mechanical latching ISO 13850 (EN 418) compliant. Diameter 40 mm (without mounting adapter).** Direct (positive) opening operation per IEC/EN 60947-5-1. *** The LPZP1A5 enclosure has replaced 8-L2PP-1A5 (discontinued). Please note changes in size (8-L2PP-1A5: 72mm x 85mm) and mounting hole location (8-L2PP-1A5: 49mm x 54mm).

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 21: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

770

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

106 mm

ø 40 mm

70 mm

56 mm

E-Stop Legend Labels (adhesive backed label)

Product Description Language Inscription Models†

60 mm diameter, non-adhesive plastic legend with “Emergency Stop” inscription

English EMERGENCY STOP 8-LM2T-AU115†

60 mm diameter (OD) Emergency Stop Legend with inscription and ISO 13850 Emergency Stop symbol (adhesive backed label).

44 mm hole for application around SSA-EB1M… (Pack of 10 each).

English EMERGENCY STOP ESL-41/60-10

English & Spanish PARADA DE EMERGENCIA ESL-41/60-ENES-10

Spanish PARADA DE EMERGENCIA ESL-41/60-ES-10

German NOT-AUS ESL-41/60-DE-10

French ARRÊT D'URGENCE ESL-41/60-FR-10

Italian EMERGENZA ARRESTO ESL-41/60-IT-10

Russian АВАРИЙНЫЙ ОСТАНОВ ESL-41/60-RU-10

Japanese 非常停止 ESL-41/60-JA-10

Simplified Chinese (Mainland China) 紧急停止 ESL-41/60-CN-10

Traditional Chinese (Taiwan) 緊急停止 ESL-41/60-TW-10

Portuguese PARADA DE EMERGÊNCIA ESL-41/60-PT-10

† Additional E-Stop background labels are available (see p/n 121976).

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 22: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

771More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

E-Stop Push-Button SpecificationsMechanical Life 300,000 operations

Operating Force 0.8 kg

Mounting Adapter Metal button: The adapter is fixed to the mounting surface by means of incorporated screws (Tmax

= 0.8 Nm)

Construction Plastic parts: Polyamide and polycarbonateMetal parts: Aluminum and zinc alloy

Environmental Rating IP65

Operating Temperature -25° to +60° C

Certifications

Compliant with EN/IEC 60947-1; -5-1

Contact SpecificationsMechanical Life 300,000 operations

European Rating Utilization categories: AC15 and DC13U

i = 690 V ac

Ith = 10A

UL designation = A 600 Q600

Rated Operating Voltage (Ue) and Current

IEC operational power in AC15

V 12 24 48 120 240 400 480 500 600

A 6 6 6 6 3 1.9 1.5 1.4 1.2

IEC operational power in DC13

V 12 14 48 125 250 440 500 600

A 3 3 1.5 0.55 0.27 0.15 0.13 0.1

Mechanical Life 1,000,000 operations

B10d 8-LM2T-Cxx 1,000,000

Connections (1 or 2) 12 AWG (2.5 mm2) maximum wire size, tightening torque: Tmax = 1 Nm

Construction Polyamide and polycarbonate

Environmental Rating IP20

Operating Temperature -25° to +60° C

Application Notes Normally Closed safety contacts (8-LM2T-C01) should only be attached to the left and right snap-on positions of the mounting adaptor. A maximum of two contact elements can be used in a single snap-on position.

Certifications

Compliant with EN/IEC 60947-1; -5-1

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 23: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

772

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Emergency Stop & Stop ControlRope pull emergency stop switches, when used with steel wire rope, provide emergency stop actuation for conveyors and large machinery.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 24: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

773More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Series Description ApplicationDimensionsH x W x D

ActuationHousing Material

RP-RM83 Rated for use in harsh environments and outdoors, and activates if the rope is pulled, becomes loose or breaks. page 774

Emergency Stop H (varies by model)90 x 53 mm Latch Metal

RP-LS42 Rugged plastic housing to withstand harsh environments and is available with an E-stop button with manual reset. page 775

Emergency Stop H (varies by model)42 x 45 mm Latch Plastic

RP-QM72 Heavy-duty switch housing withstands harsh environments. page 776

Stop-Control

RP-QM72:142 x 69 x 82 mm

RP-QMT72:181 x 69 x 82 mm

Latch Metal

RP-LM40 Heavy-duty switch housing withstands harsh environments. page 777

Stop-Control

RP-LM40D-6:124.5 x 40 x 37.5 mm

RP-LM40D-6L:147.5 x 40 x 37.5 mm

Trip & Latch Metal

RP-QM90 Heavy-duty switch housing withstands harsh environments. page 778

Stop-Control 137 x 206 x 90 mm Latch Metal

ED1G Handheld grip-style switch is typically used for manual control of machine functions, including visual observations, minor adjustments, troubleshooting, calibration and more. page 788

Stop-Control 260 x 46 x 58 mm Plastic

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 25: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

774

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

RP-RM83 Series E-Stop and Stop Control Device

Max. Rope Length

SafetyContacts

AuxiliaryContacts Action Contact State Model*

38 m 2 NC in

normal rope tension

2 NO in

normal rope tension

rope breaks

rope is pulled Safety Auxiliary 1 2 1 2open open closed closed

open open closed closed

RP-RM83F-38LTE

RP-RM83F-38LRE

RP-RM83F-38LT

RP-RM83F-38LR

75 m 2 NC in

normal rope tension

2 NO in

normal rope tension

rope breaks

rope is pulled Safety Auxiliary 1 2 1 2open open closed closed

open open closed closed

RP-RM83F-75LTE

RP-RM83F-75LRE

RP-RM83F-75LT

RP-RM83F-75LR

Models with T suffix have a Built-in Turnbuckle for ropeModels with R suffix have a Ring connection to ropeModels with E suffix have an auxiliary status output

Components for wire rope assembly kits(page 781)

RP-RM83Rope Pull E-Stop DevicesThe RP-RM83 Rope Pull Switch has a heavy-duty housing rated to IP67 for use in harsh environments and outdoors, and activates if the rope is pulled, becomes loose or breaks.

• Additional solid-state auxiliary output for remote tension monitoring• Tension indicators• Operates in a range up to 75 m• Design meets positive opening requirements for rope pull switches (IEC 60947-5-1)• Complies with ANSI NFPA 79, ANSI B11.19, IEC 60204-1, EN 13850 and

EN ISO 60947-5-5 for Emergency Stop applications

For more specifications see page 784.normal rope tension

Run Position

rope is pulled

Cable Pulled

rope breaks

Cable Break NC = Normally Closed Contact, NO = Normally Open Contact

RP-RM83 rope pulls comply with IEC 60947-5-1 Positive Opening requirements.

* See data sheet or Contact Configuration and Switching Diagrams for more information/clarification.(page 785)

For dimensions see page 779.

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 26: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

775More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

RP-LS42 Series E-Stop and Stop Control Device

Max. Rope Length

SafetyContacts

AuxiliaryContacts Action Contact State Model

25 m 2 NC in

normal rope tension

2 NO in

normal rope tension

rope breaks

rope is pulled Safety Auxiliary 1 2 1 2open open closed closed

open open closed closed

RP-LS42F-25L

RP-LS42F-25LE

RP-LS42F-25LF

37.5 m 2 NC in

normal rope tension

2 NO in

normal rope tension

rope breaks

rope is pulled Safety Auxiliary 1 2 1 2open open closed closed

open open closed closed

RP-LS42F-38L

RP-LS42F-38LE

RP-LS42F-38LF

75 m 2 NC in

normal rope tension

2 NO in

normal rope tension

rope breaks

rope is pulled Safety Auxiliary 1 2 1 2open open closed closed

open open closed closed

RP-LS42F-75L

RP-LS42F-75LE

RP-LS42F-75LF

Models with LF suffix have a Built-in Turnbuckle for ropeModels with L suffix have a Ring connection to ropeModels with LE suffix have a Built-in Turnbuckle for rope and an E-stop button

RP-LS42Rope Pull E-Stop DevicesThe RP-LS42 Rope Pull Switch has a rugged plastic housing to withstand harsh environments and has an E-stop button model with manual reset.

• Tension indicators• Operates in ranges up to 75 m• Switch activates if the rope is pulled, becomes loose or breaks• Design meets positive opening requirements for rope pull switches (IEC 60947-5-1)• Complies with ANSI NFPA 79, ANSI B11.19, IEC 60204-1, EN 13850 and

EN ISO 60947-5-5 for Emergency Stop applications

For more specifications see page 784 normal rope tension

Run Position

rope is pulled

Cable Pulled

rope breaks

Cable Break NC = Normally Closed Contact, NO = Normally Open Contact

RP-LM42 rope pulls comply with IEC 60947-5-1 Positive Opening requirements.

See data sheet or Contact Configuration and Switching Diagrams for more information/clarification.(page 785)

For dimensions see page 779.

Components for wire rope assembly kits(page 781)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 27: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

776

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

RP-QM72/QMT72 Series Stop Control Device

Max. Rope Length

SafetyContacts

AuxiliaryContacts Action Contact State Model

6 m

2 NC in

normal rope tension

—rope breaks

rope is pulled Safety Auxiliary 1 1 open closed

open closed

RP-QM72D-6L

12 m RP-QM72D-12L

20 m RP-QMT72D-20L

12 m 4 NC in

normal rope tension

—rope breaks

rope is pulled

Safety Auxiliary 1 2 1 2open open closed closed

closed closed open open

RP-QMT72F-12L

12 m 2 NC in

normal rope tension

1 NO in

normal rope tension

rope breaks

rope is pulled

Safety Auxiliary 1 2 1 2open closed closed closed

closed open open open

RP-QMT72E-12L

RP-QM72/QMT72Rope Pull SwitchesHeavy-duty switch housing withstands harsh environments and have a max rope pull length of 6, 12 or 20 m depending on model.

• Switches activate if the rope is pulled, becomes loose or breaks• Manual reset (Latch) design if the rope is pulled• Rugged metal housing with protective earth terminal (IEC 60947-1)• Comply with ANSI NFPA 79 and IEC 60204-1 for Stop Control applications

For more specifications see page 784 normal rope tension

Run Position

rope is pulled

Cable Pulled

rope breaks

Cable Break NC = Normally Closed Contact, NO = Normally Open Contact

RP-RM83 rope pulls comply with IEC 60947-5-1 Positive Opening requirements.

See data sheet or Contact Configuration and Switching Diagrams for more information/clarification.(page 785)

For dimensions see page 780.

Components for wire rope assembly kits(page 781)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 28: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

777More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

RP-LM40 Series Stop Control Device

Max. Rope Length

SafetyContacts

AuxiliaryContacts Action Contact State Model

6 m 2 NC in

normal rope tension

—rope breaks

rope is pulled Safety Auxiliary 1 1 open closed

closed open

RP-LM40D-6

RP-LM40D-6L

Models with 6 suffix use Trip actuationModels with 6L suffix use Latch actuation (typical)

RP-LM40Rope Pull SwitchesHeavy-duty switch housing withstands harsh environments.

• Manual reset (Latch) design after the rope is pulled and Auto Reset (Trip) models• Rugged metal housing with protective earth terminal (IEC 60947-1)• Switches activate if the rope is pulled, becomes loose or breaks• Design meets positive opening requirements for rope pull switches (IEC 60947-5-1)• Comply with ANSI NFPA 79 and IEC 60204-1 for Stop Control applications

For more specifications see page 784 normal rope tension

Run Position

rope is pulled

Cable Pulled

rope breaks

Cable Break NC = Normally Closed Contact, NO = Normally Open Contact

RP-LM42 rope pulls comply with IEC 60947-5-1 Positive Opening requirements.

See data sheet or Contact Configuration and Switching Diagrams for more information/clarification. (page 786)

For dimensions see page 780.

Components for wire rope assembly kits(page 781)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 29: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

778

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

RP-QM90 Series Stop Control Device

Max. Rope Length

SafetyContacts

AuxiliaryContacts Action Contact State Model

100 m(50 m each side) 2 NC in

normal rope tension

2 NO in

normal rope tension

rope breaks

rope is pulled Safety Auxiliary 1 2 1 2open open closed closed

open open closed closed

RP-QM90F-100L

RP-QM90Rope Pull SwitchesHeavy-duty switch housing withstands harsh environments.

• Manual reset (Latch) design after the rope is pulled• Rugged metal housing with protective earth terminal (IEC 60947-1)• Switch activates if the rope is pulled, becomes loose or breaks• Operates in a range up to 100 m • Design meets positive opening requirements for rope pull switches (IEC 60947-5-1)

For more specifications see page 784 normal rope tension

Run Position

rope is pulled

Cable Pulled

rope breaks

Cable Break NC = Normally Closed Contact, NO = Normally Open Contact

RP-QM90 rope pulls comply with IEC 60947-5-1 Positive Opening requirements.

See data sheet or Contact Configuration and Switching Diagrams for more information/clarification. (page 786)

For dimensions see page 780.

Components for wire rope assembly kits(page 781)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 30: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

779More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

RP-RM83F-75LT.. and RP-RM83F-38LT.. Models

90.0 mm53.0 mm

237.0 mm

RP-RM83F-75LR.. and RP-RM83F-38LR.. Models

53.0 mm

185.0 mm

90.0 mm

85.5 mm 85.5 mm

RP-LS42F-..LF Model RP-LS42F-..LE Model(with E-Stop Button)

265to

317 mm

42.0 mm45.0 mm45.0 mm

244.0 mm

RP-LS42F-..L Model

42.0 mm

124.0 mm 124.0 mm

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 31: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

780

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

RP-QMT72 Models

69.0 mm

82.0 mm

181.5 mm

69.0 mm

RP-QM72 Models

82.0 mm

142.0 mm

124.5 mm147.5 mm

37.5 mm40.0 mm

RP-LM40D-6 Model

RP-QM90 Model

RP-LM40D-6L Model

37.5 mm40.0 mm

60.0 mm 60.0 mm

90.0 mm

137.0 mm

206.0 mm

60.0 mm

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 32: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

781More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Components for Wire Rope Assembly

ModelsPackageQuantity Description Used With

Wire

Rop

es

RPA-C1-10 10 m2 mm steel wire rope with 0.5 mm red PVC jacket (unterminated)

• RP-LM40 modelsRPA-C1-20 20 m

RPA-C1-100 100 m

RPA-C2-10 10 m

3 mm steel wire rope with 0.25 mm red PVC jacket (unterminated)

• RP-LS42 models• RP-QM72/QMT72 models• RP-RM83 models

RPA-C2-20 20 m

RPA-C2-40 40 m

RPA-C2-50 50 m

RPA-C2-80 80 m

RPA-C3-20 20 m 4 mm steel wire rope with 0.5 mm red PVC jacket (unterminated)

• RP-QM90 modelsRPA-C3-100 100 m

Thim

bles

RPA-T1-4 4 pcs Thimble for 2 mm wire rope • RP-LM40 models

RPA-T2-4 4 pcs Thimble for 3 mm wire rope• RP-LS42 models• RP-QM72/QMT72 models• RP-RM83 models

RPA-T3-4 4 pcs Thimble for 4 mm wire rope • RP-QM90 models

Cla

mps

RPA-CC1-4 4 pcs Clamp for 2 mm wire rope • RP-LM40 models

RPA-CC2-4 4 pcs Clamp for 3 mm wire rope• RP-LS42 models• RP-QM72/QMT72 models• RP-RM83 models

RPA-CC3-4 4 pcs Clamp for 4 mm wire rope • RP-QM90 models

Turn

buck

les

RPA-TA1-1 1 pc #4 Turnbuckle

• RP-LM40 models• RP-LS42 models• RP-QM72/QMT72 models• RP-RM83 models

RPA-TA2-1 1 pc #5 Turnbuckle • RP-QM90 models

Eye

Bol

ts

RPA-EB1-1 1 pc 1/4" - 20 Eye bolt (3″ bolt shaft)

• RP-LM40 models• RP-LS42 models• RP-QM72/QMT72 models• RP-RM83 models

RPA-EB2-1 1 pc 5/16" - 18 Eye bolt (3″ bolt shaft) • RP-QM90 models

Pulle

ys

RPA-P1-1

1 pcRPA-P1-1Pulley for in-line use

RPA-DP1-1Pulley for

corner turns (< 180°)

• RP-LM40 models• RP-LS42 models• RP-QM72/QMT72 models• RP-RM83 models• RP-QM90 models

Tens

ioni

ng S

prin

gs

RPA-S1-1 1 pc Tensioning Spring #1 • RP-QM90 models

RPA-S2-1 1 pc Tensioning Spring #2 • RP-QM90 models

RPA-S3-1 1 pc Tensioning Spring #3• RP-LS42 models (75 m)• RP-RM83 models (75 m)

RPA-S5-1 1 pc Tensioning Spring #5 • RP-RM83 models (38 m)

RPA-S4-1 1 pcTensioning spring assembly with built-in eye bolt, cable thimble, clamp, tensioning and overload protection

• RP-LS42 models (75 m)• RP-RM83 models (75 m)

RPA-S6-1 1 pc• RP-RM83 models (38 m) • RP-LS42 models (25 & 38 m)

Term

inal

Cov

er

SI-LS42-COVER Replacement terminal cover • RP-LS42 models

RPA-DP1-1

Continued on next page

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 33: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

782

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Components for Wire Rope Assembly (cont’d)

ModelsPackageQuantity Description Used With

EZ-L

IGH

SI-K30LGRX7P 1 pc Green/Red indication• RP-LM40• RP-LS42F • RP-QM90F• RP-QM( T)72• RP-RM83F• SI-LS31• SI-LS100• SI-QS90• SI-LM40• SI-LS42SI-QM100

SI-K30LYRX7P 1 pcYellow/Red indication(used with RP-RM83F-xxLTE/-xxLRE with tension alarm)

SI-K30LRXX7P 1 pc Red indication

Indi

cato

rLa

mps

SI-PL3T-R 1 pc Red with M20 x 1.5 (24 V ac/dc)

• RP-LS42• RP-QM72/QMT72• RP-RM83• RP-QM90

SI-PL3A-R 1 pc Red with M20 x 1.5 (120 V ac)

SI-PL3T-G 1 pc Green with M20 x 1.5 (24 V ac/dc)

SI-PL3A-G 1 pc Green with M20 x 1.5 (120 V ac)

Cab

le G

land

SI-QS-CGM20 1 pc For 5 to 12 mm diameter cable

• SI-QS90 Safety Interlock Switches• SI-LS100 Safety Interlock Switches• SI-LS31 Safety Interlock Switches• SI-LS42 Safety Interlock Switches• RP-LS42 Rope Pull Switches

Con

duit

Ada

ptor

SI-QS-M20 1 pc M20 x 1.5 to ½ in-14 NPT

• SI-QS90 Safety Interlock Switches• SI-LS100 Safety Interlock Switches• SI-LS31 Safety Interlock Switches• SI-LS42 Safety Interlock Switches• RP-LS42 Rope Pull Switches

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 34: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

783More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Wire Rope Assembly Kits (Tensioning Springs ordered separately)

3 mm Rope (Length)

Thimbles(Each)

Clamps(Each)

Eye Bolts(Each)

In-Line Pulleys(Each)

Turnbuckle(Each) Kit Model

0.5 m 2 2 — — — RPAK-C2SBP-1

10 m

4 4 3 — — RPAK-CH2-10

4 4 3 3 — RPAK-CHP2-10

4 4 3 — 1 RPAK-CH2-10-TA

4 4 3 3 1 RPAK-CHP2-10-TA

20 m

4 4 6 — — RPAK-CH2-20

4 4 6 6 — RPAK-CHP2-20

4 4 6 — 1 RPAK-CH2-20-TA

4 4 6 6 1 RPAK-CHP2-20-TA

40 m

4 4 11 — RPAK-CH2-40

4 4 11 11 — RPAK-CHP2-40

4 4 11 — 1 RPAK-CH2-40-TA

4 4 11 11 1 RPAK-CHP2-40-TA

50 m

4 4 14 — — RPAK-CH2-50

4 4 14 14 — RPAK-CHP2-50

4 4 14 — 1 RPAK-CH2-50-TA

4 4 14 14 1 RPAK-CHP2-50-TA

80 m

4 4 21 — — RPAK-CH2-80

4 4 21 21 — RPAK-CHP2-80

4 4 21 — 1 RPAK-CH2-80-TA

4 4 21 21 1 RPAK-CHP2-80-TA

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 35: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

784

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

Rope Pull Switches SpecificationsContact Rating 10A @ 24 V ac, 10A @ 110 V ac, 6A @ 230 V ac, 6A @ 24 V dc

2.5 kV max. transient toleranceNEMA A300 P300

Monitoring Solid-StateOutput Rating

Rated operational voltage: Ue= 10 to 30 V dc

Rated operational current: Ie= 50 mA

Utilization category: DC13Protected against reverse polarity and short circuit.

European Rating Utilization categories: AC15 and DC13 U

i= 500V ac, I

th= 10A

Rated Surge Capacity: 2.5 kV (RP-RM83 only)

RP-RM83 models (40-60 Hz)U

e

V Ie/AC-15

AIe/DC-13

A120 6 0.55240 3 0.27

All others (40-60 Hz)U

e

V Ie/AC-15

AIe/DC-13

A24 10 6110 10 1230 6 0.4

Contact Material Silver-nickel alloy

Maximum Switching Speed RP-RM83 models: 20 operations per minute All others: 50 operations per minute

Recommended Rope Size 40 mm models: 2 mm diameter steel rope42 & 72 mm models: 3 mm diameter steel rope83 mm models: 2-5 mm diameter steel rope (3 mm recommended)90 mm models: 4 mm diameter steel rope

Maximum Rope Pull Length RP-LM40D-6/6L and RP-QM72D-6L: 6 mRP-LS42F-75L/75LE/75LF: 75 m RP-LS42F-38L/38LE/38LF: 37.5 m RP-LS42F-25L/25LE/25LF: 25 m RP-QM72D-12L: 12 mRP-QMT72D-20L: 20 m RP-QMT72E-12L and RP-QMT72F-12L: 12 mRP-RM83F-75LTE/LT/LRE/LR: 75 m RP-RM83F-38LTE/LT/LR/LRE: 38 mRP-QM90F-100L: 100 mm; equal lengths up to 50 m on either side of switch

Short Circuit Protection 10 amp Slow Blow, 15 amp Fast Blow.Recommended external fusing or overload protection.

Mechanical Life RP-RM83: 100,000 operationsAll others: 1 million operations

Wire Connections Screw terminals with pressure plates accept the following wire sizes –Stranded and solid: 20 AWG (0.5 mm2) to 16 AWG (1.5 mm2) for one wireStranded: 20 AWG (0.5 mm2) to 18 AWG (1.0 mm2) for two wires

Cable Entry M20 x 1.5 threaded entranceAdapter supplied to convert M20 x 1.5 to ½" - 14 NPT threaded entrance

Construction RP-LS42F-..L/..LE/..LF: High-impact thermoplastic housing; zinc die-cast actuatorAll others: Aluminum alloy die cast

Environmental Rating RP-LS42F and RP-RM83F models: NEMA 4; IEC IP67All other models: NEMA 4; IP65

Operating Temperature RP-LS42F-..L/..LE/..LF: -25° to +70° C All other models: -30° to +80° C

Weight RP-LM40D-6: 0.22 Kg RP-LM40D-6L: 0.26 KgRP-LS42F-..L: 0.48 Kg RP-LS42F-..LE and RP-LS42F-..LF: 0.65 KgRP-QM72D-6L: 0.49 Kg RP-QM72D-12L: 0.52 KgRP-QMT72D-20L, RP-QMT72E-12L and RP-QMT72F-12L: 0.64 KgRP-QM90F-100L: 3.8 KgRP-RM83F-75LT and RP-RM83F-75LTE: 1 Kg RP-RM83F-75LR and RP-RM83F-75LRE: 0.77 KgRP-RM83F-38LT and RP83FLT8: 1 Kg RP-RM83F-38LR and RP-RM83F-38LRE: 0.77 Kg

Certifications

(RP-RM83 and RP-LS42 only)

Contact Configurations and Switching Diagrams

RP-LM40 models: SD13 (page 786)RP-LS42 models: SD05, SD06 & SD07 (page 785)RP-QM72/QMT72 models: SD07, SD08, SD09, SD10 & SD11 (page 786)RP-RM83 models: SD01, SD02, SD03 & SD04 (page 785)RP-QM90 models: SD15 (page 786)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 36: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

785More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

SD02 - RP-RM83F-38LTE/LRE Series

Contact Configuration Switching Diagram

Run Position

-6

+6

-4.8-4-3

+4+3

mm

+4.8

11-1

2

23-2

4

Break (91N) 11-1

2

23-2

4

2-3

S2S1

TensionSet Point

133N

Latch

Pull (175N)

Latch

Safe

tyM

onito

r

Safe

tyM

onito

r

Aux

.

Aux.

S1 S2

1211

2423

1211

2423

Cable Pull or Break

S1 S2

1211

2423

1211

2423 Open Closed

Page 774

SD01 - RP-RM83F-75LTE/LRE Series

Contact Configuration Switching Diagram

Run Position

-6

+6

-4.8-4-3

+4+3

mm

+4.8

11-1

2

23-2

4

Break (156N) 11-1

2

23-2

4

2-3

S2S1

TensionSet Point

228N

Latch

Pull (300N)

Latch

Safe

tyM

onito

r

Safe

tyM

onito

r

Aux

.

Aux.

S1 S2

1211

2423

1211

2423

Cable Pull or Break

S1 S2

1211

2423

1211

2423 Open Closed

Page 774

SD05 - PR-LS42F-25/38/75xx

Contact Configuration Switching Diagram

Run Position

0 mm 80N / 140N / 240N

100N / 175N / 300N

60N / 105N / 180N

Operating point ± 0.5 mmActuating force ± 15%

Latch

Latch

Mon

itorin

gSa

fety

Mon

itorin

gSa

fety

-5 mm

+3.5 mm+4.3 mm

+5 mm

-4.3 mm-3.5 mm

13-1

421

-22

33-3

441

-42

Contacts: Open Closed Transition

14223442

13213341

Run

Cable Pulled or Cable Break

14223442

13213341

Pull / Break

Open Closed Transition

SD06 - RP-QM72D-6L Series

Cable Position Switching Diagram

Run Position

13-1

4

25-2

6

Bre

ak

Pull

90N

120N

0

2

4

6

mm

25 26

13 14

Cable Pulled

25 26

13 14

Cable Break

25 26

13 14 Open Closed

Page 776

SD04 - RP-RM83-38LT/LR Series

Contact Configuration Switching Diagram

Run Position

-6

+6

-4.8-4-3

+4+3

mm

+4.8

11-1

2

23-2

4

Break (91N) 11-1

2

23-2

4

2-3

S2S1

TensionSet Point

133N

Latch

Pull (175N)

Latch

Safe

tyM

onito

r

Safe

tyM

onito

r

Aux

.

Aux.

-6

+6

-4.8-4-3

+4+3

mm

+4.8

11-1

2

23-2

4

Break (91N) 11-1

2

23-2

4

2-3

S2S1

TensionSet Point

133N

Latch

Pull (175N)

Latch

Safe

tyM

onito

r

Safe

tyM

onito

r

Aux

.

Aux.

S1 S2

1211

2423

1211

2423

Cable Pull or Break

S1 S2

Open Closed

Page 774

SD03 - RP-RM83-75LT/LR Series

Contact Configuration Switching Diagram

Run Position

-6

+6

-4.8-4-3

+4+3

mm

+4.8

11-1

2

23-2

4

Break (156N) 11-1

2

23-2

4

2-3

S2S1

TensionSet Point

228N

Latch

Pull (300N)

Latch

Safe

tyM

onito

r

Safe

tyM

onito

r

Aux

.

Aux.

-6

+6

-4.8-4-3

+4+3

mm

+4.8

11-1

2

23-2

4

Break (156N) 11-1

2

23-2

4

2-3

S2S1

TensionSet Point

228N

Latch

Pull (300N)

Latch

Safe

tyM

onito

r

Safe

tyM

onito

r

Aux

.

Aux.

S1 S2

1211

2423

1211

2423

Cable Pull or Break

S1 S2

Open Closed

Page 774

1211

2423

1211

2423

1211

2423

1211

2423

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 37: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

786

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

SD08 - RP-QMT72D-20L Series

Cable Position Switching Diagram

Run Position

13-1

4

25-2

6

Bre

ak

Pull

50N

180N

0

2

11

13

mm

25 26

13 14

Cable Pulled

25 26

13 14

Cable Break

25 26

13 14 Open Closed

Page 776

SD07 - RP-QM72D-12L Series

Cable Position Switching Diagram

Run Position

13-1

4

25-2

6

Bre

ak

Pull

150N

240N

0

1.5

5

7.5

mm

25 26

13 14

Cable Pulled

25 26

13 14

Cable Break

25 26

13 14 Open Closed

Page 776

SD11 - RP-LM40D-6 Series

Cable Position Switching Diagram

Run Position

13-1

4

25-2

6

Bre

ak

Pull

50N

70N

0

1.6

3.6

4.4

5.0mm

25 26

13 14

Cable Pulled

25 26

13 14

Cable Break

25 26

13 14 Open Closed Transition

Page 777

SD10 - RP-QMT72E-12L Series

Cable Position Switching Diagram

Run Position

13-1

4

25-2

6

Bre

ak

Pull

80N

200N

0

2

6

8

mm

33-3

4B

reak

25 26

13 14

33 34

Cable Pulled

25 26

13 14

33 34

Cable Break

25 26

13 14

33 34

Open Closed

Page 776

SD12 - RP-LM40D-6L Series

Cable Position Switching Diagram

Run Position

13-1

4

25-2

6

Bre

ak

Pull

50N

70N

0

1.2

3.2 Latch

4.8mm

25 26

13 14

Cable Pulled

25 26

13 14

Cable Break

25 26

13 14 Open Closed Transition

Page 777

SD09 - RP-QMT72F-12L Series

Cable Position Switching Diagram

Run Position

13-1

4

25-2

6

Bre

ak

Pull

80N

200N

0

2

6

8

mm

33-3

4

45-4

6

Bre

akPu

ll

25 26

45 46

13 14

33 34

Cable Pulled

25 26

45 46

13 14

33 34

Cable Break

25 26

45 46

13 14

33 3426

14

Open Closed

Page 776

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 38: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

787More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

SD13 - RP-QM90F-100L Series

Cable Position Switching Diagram

Run Position

11 -

1223

- 24

40°

40°

30°

30°

0

Lock

70N

70N

Lock

Leve

r

11 -

1223

- 24

Rig

htLe

ft

24 12

11

12

1123

24

23

Cable Pulled or Break

24 12

11

12

1123

24

23 Open Closed

Page 778

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 39: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

788

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

ED1GEnabling DevicesHandheld grip-style switch is typically used for manual control of machine functions, including visual observations, minor adjustments, troubleshooting, calibration and more.

• Provides the three-position functionality (OFF-ON-OFF) required for manual control of a machine, including enabling and hold-to-run applications

• Ergonomic design has a detented enable position (position 2)• Design meets or exceeds: ANSI RIA R15.06 and ISO 10218 Robot safety

standard, ANSI B11.19 Performance Criteria for Safeguards, and ANSI NFPA 79 (2007) and IEC 60204-1 (2000) Electrical Requirements for Industrial Machines

ED1G Series Enabling Devices, Stop Control Devices

Contact ConfigurationAdditional

Push-Button Switch Environmental Rating Model

2 NO&

1 NC Aux— IP66 ED1G-L21SM-1N

1 NO&

1 NC Aux&

1 NO Momentary Push Button

MomentaryPush Button

IP65 ED1G-L21SMB-1N

2 NO&

2 NO Momentary Push Button

MomentaryPush Button

IP65 ED1G-L20MB-1N

58.0 mm46.0 mm

269.0 mm260.0 mm

58.0 mm46.0 mm

ED1G-L21SM-1N Model ED1G-L21SMB-1N Model

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 40: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

789More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

ED1G Enabling Device SpecificationsSupply Voltage and Current 250 V ac/dc

Impulse Withstand Voltage Three Position Switch: 2.5 kVMomentary pushbutton: 1.5 kV

Output Contact Ratings Rated Insulation Voltage (UI): 3-position switch 250 V; momentary push button 125 VRated Thermal Current (Ith): 2.5 A**40°C ≤ operating temperature < 50° C: 2 A (4 contacts under load)*50°C ≤ operating temperature ≤ 60° C: 1.5 A (3 contacts under load

Contact Resistance 100 mohm max.

Insulation Resistance Live to dead metal parts: 100 Mohm min. Positive to negative live parts: 100 Mohm min.

Recommended Wire/Cable Size Wire: 0.14 to 1.5 mm² (25 AWG to 16 AWG) Cable: ø 7 to 13 mm M20 conduit

Short Circuit Protection 250 V / 10A fast blow fuse (IEC 60127-1) Conditional short circuit current: 50 A (250 V)

Vibration Resistance Operating extremes: 5 to 55 Hz, half amplitude 0.5 mm minimumDamage limits: 16.7 Hz, half amplitude 1.5 mm minimum

Shock Resistance Operating extremes:150 m/s² (15 G) Damage limits: 1,000 m/s² (100 G)

Mechanical Life Positions 1 & 2 only: 1,000,000 operations minimum Positions 1, 2 & 3: 100,000 operations minimumOperating frequency: 1,200 operations per hour maximum

Electrical Life 100,000 minimum at rated load

Pollution Degree 3

Terminal Pulling Strength 20 N minimum

Terminal Screw Torque 0.5 to 0.6 N

Operating Conditions(indoor use only)

Temperature: –10° to +60° C (no freezing) Humidity: 45 to 85% RH max. (no condensation)Storage Temperature: –40° to +80° C (no freezing)

Construction Polyamide housing and cable gland, NBR/PVC polyblend rubber grip switch boot; model ED1G-L21SM-1N meets IP66; other models meet IP65

Design Standards IEC 60947-5-1, EN 60947-5-1, JIS C8201-5-1, UL 508, CSA C22.2 No. 14, GS-ET-22

Certifications

Contact Configurations and Switching Diagrams SD01, SD02 and SD03 (page 785)

Rated Current (Ie) Monitor Switch Terminals 5-6(models..-L21SM.. and..-L21SMB..)

Rated Voltage Ue 30 V 125 V 250 V

ACResistive load (AC-12) — 2 A 1 A

Inductive load (AC-15) — 1 A 0.5 A

DCResistive load (DC-12) 2 A 0.4 A 0.2 A

Inductive load (DC-13) 1 A 0.22 A 0.1 A

Rated Current (Ie) Momentary Push Button Switch Terminals 7-8 (model ..-ED1G-L21SMB-1N..);

5-6 and 7-8 (model ED1G-L20MB-1N)

Rated Voltage Ue 30 V 125 V 250 V

ACResistive load (AC-12) — 0.5 A —

Inductive load (DC-15) — 0.3 A —

DCResistive load (AC-12) 1 A 0.2 A —

Inductive load (DC-13) 0.7 A 0.1 A —

Rated Current (Ie) 3-Position Switch Terminals 1-2 and 3-4 (all models)

Rated Voltage Ue 30 V 125 V 250 V

ACResistive load (AC-12) — 1 A 0.5 A

Inductive load (AC-15) — 0.7 A 0.5 A

DCResistive load (DC-12) 1 A 0.2 A —

Inductive load (DC-13) 0.7 A 0.1 A —

BracketsED1G

See page 901

ED9Z-GH1

Additional brackets and information available.See page 852

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 41: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

790

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

SD01 - ED1G-L21SM-1N Series

Terminal No.

1 Safety

Monitor

Monitor

Safety

Safety

Monitor

Safety

Safety

Safety

-2

5-6

3-4

Pressing(Position 1→2→3)

1-2

5-6

3-4

Releasing(Position 2→1)

1-2

contact ON(closed)

contact OFF(open)

5-6

3-4

Releasing(Position 3→1)

Position 1 Position 2 Position 3

SD02 - ED1G-L21SMB-1N Series

Terminal No.

1 Safety

Monitor

Monitor

Safety

Safety

Monitor

Safety

Safety

Safety

-2

5-6

3-4

Pressing(Position 1→2→3)

1-2

5-6

3-4

Releasing(Position 2→1)

1-2

contact ON(closed)

contact OFF(open)

5-6

3-4

Releasing(Position 3→1)

Position 1 Position 2 Position 3

SD03 - ED1G-L20MB-1N Series

Terminal No.

Safety

Safety

Safety

Safety

Safety

Safety

1-2

contact ON(closed)

contact OFF(open)

3-4

Releasing(Position 3→1)

Position 1 Position 2 Position 3

1-2

3-4

Releasing(Position 2→1)

1-2

3-4

Pressing(Position 1→ →2 3)

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com

Page 42: Emergency Stop Buttons - Steven Engineering › Tech_Support › PDFs › 04_MAIN...• Rugged design • Push-to-stop, twist-to-release or pull-to-release operation per IEC 60947-5-5

791More information online at bannerengineering.com

SAFETY LIGHT SCREENS CONTROLLERS & MODULES

EMERGENCY STOP & STOP CONTROL

INTERLOCK SWITCHES

LASER SCANNERS TWO-HAND CONTROL

The following standard products are still available from Banner.Please go online to bannerengineering.com for full descriptions and technical references.

PICO-GUARD™ Grids & Points PICO-GUARD™ Interlock Switches

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com