ella low threshold applied acrylic showers owner's …€¦ · shower as a trash receptacle!...

16
3648 SH 1S 3P 4.0 Right Seat/Left Seat 6033 SH 3PS Right Seat/Left Seat 4836 SH 4P 3.0 Center Drain 6033 SH 5P 4.0 Center Drain 6030 SH 5P 4.0 Right/Left Drain ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S MANUAL REPRESENTING THESE MODEL NUMBERS:

Upload: others

Post on 11-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

3648 SH 1S 3P 4.0 Right Seat/Left Seat

6033 SH 3PS Right Seat/Left Seat

4836 SH 4P 3.0Center Drain

6033 SH 5P 4.0Center Drain

6030 SH 5P 4.0Right/Left Drain

ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERSOWNER'S MANUAL

REPRESENTING THESE MODEL NUMBERS:

Page 2: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6
Page 3: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

Getting Started ................................................................................................................................... 1

Installation Procedure ..................................................................................................................... 2-4

Limited Warranty ................................................................................................................................ 5

Framing Dimensions ........................................................................................................................... 6

Shower Diagrams ............................................................................................................................... 7

Warranty Information ........................................................................................................................ 8

Warranty Activation Form .............................................................................................................9-10

www.ellasbubbles.com 10/17

Contents

Page 4: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6
Page 5: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

Thank you for purchasing an Ella Low Threshold Shower System. For best results, please read and follow all directions carefully before beginning installation.

Tools/Materials you might need for proper installation:

IMPORTANT! READ ALL INSTRUCTIONS1. The back of a fiberglass unit is not waterproof. Unit must be stored so water will drain off

and not acumulate in one spot. Water can penetrate the back laminates and soak theglassed in reinforcement supports causing bulges in the gelcoat unit.

2. Most handling damage is the result of impact blows to the back of hte fiberglass units.

3. Never drag a fiberglass unit on any surface. Always transport the unit y hand using (2)people or two wheel dolly.

4. Never let a fiberglass unit drop from any height, not even an inch or stress cracks are likelyto occur.

5. Placing objects inside the unit can cause scratches or nicks to the surface. Do not use theshower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower.

6. Never clean fiberglass gelcoat surface with metal tools of any kind, including razor blades.

Getting Started

INSTALLATION INSTRUCTIONS

Pre-Installation Planning

1.

2.

3.

Do Not store units out of doors.- Keep out of sunlight and exposure to weather.

Review Figures 7, 8, and 9 to makesure alcove is of proper size. If a fire rated

alcove is required, approved finish material mustbe installed prior to unit installation. Access todrain and supply connections should be providedso that these connections may be made after theunit has been installed. Framing alcove mustreflect interior dimensions on diagram to permitinstallation of unit. Note in diagram the requiredopening in the floor to provide clearance for thedrain fitting and connection.

Placement of the two wood shims (provided)is MANDATORY to provide bottom structural

support of the base unit. See Figure 1.

3.

Installation ProcedureRemove wall section(s) from the baseunit. Carefully move all parts into the installation

area. Apply a bead of silicone to all joints. Reinstallwall sections. Align all parts, and connect withthe metal fasteners. Wipe away any excess caulkthat squeezes out. The unit will be installed inthe framed alcove as a one-piece unit.

If installing piece-by-piece into the alcove, Alternate Connection: Plastic Fasteners:

use the plastic fasteners. These fasteners

Drain and/or Overflow assembly shouldbe installed on unit according to the

manufacturers instructions. Apply a bead of 100%silicone caulk around the drain opening in unitbefore installing the fitting.

Locate supply lines for control valvesand shower head. Measure and mark locations

of fittings on the finished side of the unit. Rechecklocations, and drill 1/4’’ pilot holes. Cut holes tofinal size using the appropriate size hole saw.

4.

1.

2.

5 .

6.

7.

8.

Plumb and level the unit in two directions:Place a level on top of the apron, and along the

finished flat area at the top of the wall. Once the unitis leveled, if any gap appears between the apron andsub floor fill the gap with solid material. When satisfiedwith the fit, attach the unit to framing with 6d galvanizednails or screws through the predrilled holes in themounting flanges. If required, drill additional holesthrough the flanges in order to attach the unit to eachstud.

Make connections to supply and drainlines. Strap all lines to the framing. Install finish

trim. Caulk as necessary.

Check for leaks before installing wall-board and closing off plumbing access.

Finish wallboard asdetailed inthe diagram.

Shim AlongFraming

WallBoard

Mount ingFlange

CaulkGap

Framing

SECTIONAL GELCOAT BATHING SYSTEMS

Wood Support Shims

Two wood shims are provided in the installationpacket attached to the unit. Additonal shims may beadded by the installer.

READ INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION.

permit a “blind” installation so shower parts mayconnected together in the installation location.The unit parts are held in alignment with the plasticfastener pins. When the caulking cures, the partsare solidly held together similar to a one piece unit when attached to the framing. Follow the instructions on Pages 2 and 3 if using the plastic fasteners in place of the metal fasteners.

Apply wood wedges to the alcove floor.Carry unit to the opening. Align front of apron

to final location and tilt unit into place. Make certainthat the wood shims contact both the bathing unitand sub floor. Remove and adjust wedges ifnecessary to assure proper contact for support.

It is MANDATORY that these wedges are in placeand in proper contact to assure structural integrityof the bathing unit.

Figure 2

1

Figure 1

• 6D Galvanized Screws• 100% silicone caulking• Caulking gun• Acrylic latex caulk• Shims

• Tape measure• 1/8" drill bit• Phillips screw driver• Cardboard• China marker /

grease pencil

• Furring strips• Construction adhesive• Long spirit level

www.ellasbubbles.com Page 1 10/17

Page 6: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

1. Remove wall section(s) from the base unit. Carefully move all parts into the installationarea. Apply a bead of silicone to all joints. Reinstall wall sections. Align all parts, and connectusing the alignment pins. Wipe away any excess caulk that squeezes out. The unit will beinstalled in the framed alcove as a one-piece unit. The unit must be installed completelylevel.

Alternate Connection: If installing piece by piece into the alcove, make sure that the pins are aligned correctly. When the caulking cures the parts are solidly held similar to the one piece when attached to the framing. See Photo1. The valve wall should be the first wall sections installed.

2. Drain and/or Overflow assembly should be installed on unit according to themanufacturer’s instructions. Apply a bead of 100% silicone caulk around the drain opening inunit before installing the fitting.

3. Locate supply lines for control valves and shower head. Measure and mark locations offittings on the finished side of the unit. Recheck locations, and drill 1/4" pilot holes. Cut holesto final size using the appropriate size hole saw.4. Apply wood wedges to the alcove floor. Carry unit to the opening. Align front of apronto final location and tilt unit into place. Make certain that the wood shims contact both thebathing unit and sub floor. Remove and adjust wedges if necessary to assure proper contactfor support.

It is MANDATORY that these wedges are in place and in proper contact to assure structural integrity of the bathing unit.

5. Plumb and level the unit in two directions: Place a level on top of the apron, and alongthe finished flat area at the top of the wall. Once the unit is leveled, if any gap appearsbetween the apron and sub floor fill the gap with solid material. When satisfied with the fit,attach the unit to framing with 6d galvanized nails or screws through the pre-drilled holes inthe mounting flanges. If required, drill additional holes through the flanges in order to attachthe unit to each stud.

6. Make connections to supply and drain lines. Strap all lines to the framing. Install finish trim.Caulk as necessary.

7. Check for leaks before installing wall-board and closing off plumbing access.

8. Finish wall board as detailed in Figure 2.

Installation Procedure 1 of 3

Photo 1

www.ellasbubbles.com Page 2 10/17

Page 7: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

8. Finish wall board as detailed in Figure 2.

Sectional bathing units are shipped from the factory with screws or nuts and bolts connecting the parts together.

If installing the unit fastened together in one piece, follow instructions on Page 1 of this manual.

The alignment pins should allow you to more easily install the unit in the framing alcove. Read and understand the instructions on this page since the alignment pins must be inserted in a specific direction.

1. Install drain and/or overflow assembly on unit following drain manufacturers instructions.Place support wedges under the back edge and secure Place the base unit in the installlocation. Level the unit. A minimum of two shims should be used for proper support. (SeeFigure 5). Re-check level and attach base to framing studs with 6D galvanized screws.

2. Place a continuous bead of silicone on base between the edge of the base and the holes.For three and four piece units, apply silicone up the vertical seam(s) at the front or insideedge of the wall. Also around the pin alignment piece.

3. Place the walls on the top of the base aligning the holes with the pins. For three and fourpiece units, install the left wall first. Repeating the same for the right wall. Press all seamstogether to assure a tight fit. Wipe away any excess caulking. See Figure 5

4. For four piece units, install the back wall first. Install the left and right walls (Wet wall last).Press the seams together, to assure a tight fit. Wipe away any excess caulking before it cures.

5. Make sure all seams are even and in alignment with the base section. Fasten the wallassembly to the framing using 6D galvanized screws through the mounting flanges. Fastenevery 8" O.C. along the vertical flanges and to each framing stud along the top, horizontally.

Installation Procedure 2 of 3

SIDE VIEW

INTEGRAL SELF-LOCATING METAL GUIDE PIN DETAIL

INTEGRAL SELF-LOCATING METAL GUIDE PINS PAN BASE DETAIL

www.ellasbubbles.com Page 3 10/17

Page 8: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

6. Make connections to supply and drain lines. Strap all lines to the framing. Install finish trim.Caulk as necessary.

7. Check for leaks before installing wall-board and closing off plumbing access.

8. Finish wall board as detailed in Figure 6.

CAUTIONIf you use a RUBBER FLOOR MAT in this tub or shower unit it must be removed after each usage. If left in the unit, it may cause blisters or damage to the surface finish.

DO NOT USE ABRASIVE CLEANERSThe most important caution is to avoid use of harsh abrasive cleaners or gritty scouring powders. To clean the unit, simply use a household liquid detergent with soft sponge cloth and warm water. More persistent stains, tar, or paint can be removed with naptha or mineral spirits. Remove excess plaster by scraping with a sharpened soft wood stick. Avoid wire brushes, metal scrapers or tools. Restore dull areas by rubbing with automotive type body cleaning compound.

1.

4.

Remove the nuts and bolts to disassemble the wallsection(s) from the base unit. Carefully move all

parts into the installation area.

Install drain and/or overflow assembly on unitfollowing drain manufacturers instructions.

Place support wedges under the back edge and secure Place the base unit in the install location. Level the unit.

with adhesive. A minimum of two shims should be usedfor proper support. (See Figure 5). Re-check level and attach base to framing studs with 6D galvanized screws.

6.

2.

USING PLASTIC FASTENERS TO STABILIZETHE WALLS ON SECTIONAL BATHING UNITS

Fiberglass Unit

Apply a bead of silicone to the inside head of theplastic fasteners. Insert the plastic fasteners in the

holes on the base ledge coming in from the bottom(outside) and pushing them upward so they point towardthe ceiling. See Figure 3.

The head of the fastener and silicone should makecontact with bottom ledge of the base.

Silicone Bead

Plastic Fastener

3. For three piece units, after applying thesilicone to the head of the plastic fasteners for the

wall, insert them from the backside through the holesin the vertical seam on the left wall (the wall to the leftas you face the unit) so they are facing the right andthe heads of them are pressed firmly to the backsideof the flanges.For four piece units, after applying the silicone to thehead of the plastic fasteners for the walls, insert themon the two front vertical flanges of the back wall. Thesefasteners will be inserted from the backside and pressedthrough until the head of the fasteners fully contact theflanges. These fasteners will be pointing out towardsthe front of the bathing unit.

5. The silicone on the plastic fasteners should beallowed time to dry. Use four wooden blocks on

the top ledge. Space evenly along the ledge. Tape themin place. They will be used to temporarily space the wallabove the base while it is being placed. See Figure 4A.

7.

Sectional bathing units are shipped from the factorywith screws or nuts and bolts connecting the partstogether.

If installing the unit fastened together in one piece,follow instructions on Page 1 of this manual.

If you will be installing the base first then the separatewall sections, it is recommended you use the plasticfasteners. The plastic fasteners are especially usefullwhen installing a three or four piece bathing unit.

Using the plastic fasteners should allow you to moreeasily install the unit in the framing alcove. Read andunderstand the instructions on this page since theplastic fasteners must be inserted in a specific direction.

Support Wedges(Secure with adhesive)

Wood Blocks 1/4” Bead ofSilicone Caulk

Place a continuous bead of silicone onbase between the edge of the base and the holes

(As shown in Figure 4B). For three and four pieceunits,apply silicone up the veritical seam(s) betweenthe holes for the fasteners and the front or inside edgeof the wall.

Figure 3

Figure 4B

Place the walls on top of the wooden blocks. Oneby one remove the blocks taking care to align the

plastic fasteners into the holes in the underside of thewalls. For three piece units, install the left wall first.Repeat for the right wall. Press all seams together to

8. For four piece units, install the back wall first. Installthe left and right walls, (Wet wall last.) Take care to

align the plastic fasteners into the holes in the walls.Press the seams together, to assure a tight fit. Wipe away any excess caulking before it cures.

assure a tight fit. wipe away any excess caulking.See Figure 5.

2

Figure 5

Figure 4A

Installation Procedure 3 of 3

www.ellasbubbles.com Page 4 10/17

Page 9: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

LIMITED WARRANTYElla's Bubbles, LLC warrants to the owner of its Tub/Shower units as follows: Units manufactured of fiberglass reinforced polyester resin, that it will, free of charge, repair or exchange as its option, any Ella's Bubbles unit found to be defective in materials or workmanship upon inspection by an authorized representative of Ella's Bubbles for a period of three (3) years from date of purchase.

The exchange of a unit is limited to supplying a replacement unit of comparable size and style and does not include any costs of removal or installation.

This warranty shall be voided if the unit is moved from its place of initial installation or is not installed in accordance with the instructions supplied by the manufacturer of the unit. Further, this warranty does not apply if the unit has been subjected to accident, abuse, misuse, damage caused by flood, fire or act of God.

Since local code requirements vary greatly throughout the country, distributors, dealers, installation contractors and users of plumbing products should determine whetherthere are any code restrictions on the use of a specific product. Ella's Bubbles makes no representation or warranty regarding and shall not be responsible for any code compliance.

The owner agrees by use of this unit that the obligations of Ella's Bubbles shall not exceed to contingent or indirect damage or injury to the structure of its contents, that the obligations of Ella's Bubbles are limited to those set forth herein, and that no other obligations, expressed or implied, are assumed by Ella's Bubbles.

©2014, Ella's Bubbles, LLC2101 S. Carpenter St., Chicago, IL 608081.800.480.6850www.ellasbubbles.com

Limited Warranty

www.ellasbubbles.com Page 5 10/17

Page 10: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

Framing Dimensions

9.

10.

11.

12.

G 3838.51

Model No.

6824/25

6839

Fig 5 Fig 7 Fig 6 A B C D E F G H I J

N/A N/A 27”79”73”74”74”74”

73”73”

73”

39-1/2”

60-1/4”32-1/4”36-1/4”48-1/4”

36-1/4”48-1/4”

60-1/4”

39-1/2”31-7/8”

33-1/2”

36-1/2”

37-5/8”35-5/8”31-1/4”

17-3/4”14-3/4”16-1/2”

18”18”

16-1/8”16-3/8”14-1/2”

17-3/4” 17-3/4”2-5/8”16”18”24”

18”

24”

1-3/8”

14-3/4”16-1/2”

18”18”

16-1/8”16-3/8”

14-1/2”

75”76”76”76”

83-3/4”83-3/4”83-1/8” 83-1/8”

83-3/4”83-3/4”

82”82”82”81”

48”

19”48”48”48”

48”48”

17-1/2”

42-1/4”22”

22”22”

22”22”

43”

XX

XXX

X

XX

36-1/2”

Old No.

G 3838 NA 2P

G 6032 TS 2P

G 3232 SH 2PG 3635 SH 2PG 4836 SH 2P 1S

G 3636.53

G 6030.75G 6036.71 6976/77 X 76” 60-1/4” 35-3/4” 15” 2” 15” 79” 82” 25-1/4” 38-1/4”G 6036.72 6880/81 X 81” 60-1/4” 37” 17-1/2” 1-5/8” 17-1/2” 81-1/4” 81-1/4” 22” 42-1/2”

G 6030.74

G 3232.50G 3635.53G 4835.54

G 4834.50G 4834 3P 2S

G 3260 TS 3P N/AG 5494 TS 2P N/A

G 4887 SH 3P 1S N/A

XX

X

60-1/4”74” 32-3/4” 16” N/A 16” N/A N/A N/AN/A N/A N/A

N/AN/AN/A74” 54-1/4” 27-1/2” 12-1/4” N/A 12-1/4”

N/AN/AN/A

78” 48-1/4” 35-3/4” 18-1/4” 24” 18-1/4”

FRAMING DIMENSIONS

Do not use abrasive cleaners

If you use a RUBBER FLOOR MAT in thistub or shower unit it must be removed after eachusage. If left in the unit, it may cause blisters ordamage to the surface finish.

G 6017 TS 2P N/A X 81” 60-1/4” 37-3/4” 16” N/A 16” N/A N/A N/A N/AG 4887 SH 2P 1S N/A X 78” 48-1/4” 35-3/4” 18-1/4”18-1/4” 24” 18-1/4” N/A N/A N/A N/AG 3679 SH 3P N/A X 78” 36-1/4” 37” 19” 18” 19” N/A N/A N/A N/AG 3687 SH 2P XN/A 79” 36-1/4” 36-1/4” 17-1/2” 18” 17-1/2” N/A N/A N/A N/AG 3275 SH 2P XN/A 77” 32” 34” 19-1/2” 16” 19-1/2” N/A N/A N/A N/A

XG 4080 NA 2P N/A 81” 41-1/4” 41-1/4” 19” 19” 19” N/A N/A N/A N/A

Praxis Companies LLC.435 Industrial Road

Savannah, TN. 38372

Phone: (800) 443-7269Fax: (731) 925-7656

Make sure all seams are even and in alignment with the base section. Fasten the wall assembly

to the framing using 6D galvanized screws through the mounting flanges. Fasten every 8” O.C. along the verticalflanges and to each framing stud along the top, horizontally.

3

The most important caution is to avoid use of harshabrasive cleaners or gritty scouring powders. To cleanthe unit, simply use a household liquid detergent withsoft sponge cloth and warm water. More persistentstains, tar, or paint can be removed with naptha ormineral spirits.Remove excess plaster by scraping with a sharpenedsoft wood stick. Avoid wire brushes, metal scrapersor tools. Restore dull areas by rubbing with automotivetype body cleaning compound.

CAUTION:

Make connections to supply and drainlines. Strap all lines to the framing. Install finishtrim. Caulk as necessary.

Check for leaks before installing wall-board andclosing off plumbing access.

Finish wallboard asdetailed inthe diagram.

Shim AlongFraming

WallBoard

Mount ingFlange

CaulkGap

Framing

Figure 6

www.ellasbubbles.com Page 6 10/17

Page 11: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

Shower Diagrams

Sectional Gelcoat Tub/Showers

G 3838 2P and G 4080 2P Showers

Sectional Gelcoat Showers

Praxis Companies warrants to the owner of its Tub/Shower units as follows:Units manufactured of fiberglass reinforced polyester resin, that it will, free of charge, repair or exchange as its option, any Praxis Companies unit found to be defectivein materials or workmanship upon inspection by an authorized representitive of Praxis Companies for a period of three (3) years from date of purchase. The exchangeof a unit is limited to supplying a replacement unit of comparable size and style and does not include any costs of removal or installation.This warranty shall be voided if the unit is moved from its place of initial installation or is not installed in accordance with the instructions supplied by the manufacturerof the unit. Further, this warranty does not apply if the unit has been subjected to accident, abuse, misuse, damage caused by flood, fire or act of God.Since local code requirements vary greatly throughout the country, distributers, dealers, installation contractors and users of plumbing products should determine whetherthere are any code restrictions on the use of a specific product. Praxis Companies makes no representation or warranty regarding and shall not be responsible forany code compliance.The owner agrees by use of this unit that the obligations of Praxis Companies shall not exceed to contingent or indirect damage or injury to the structure of its contents,that the obligations of Praxis Companies are limited to those set forth herin, and that no other obligations, expressed or implied, are assumed by Praxis Companies.Contact: Praxis Companies Customer Service Department: Phone (800) 326-5489. Fax (888) 246-0466.

LIMITED WARRANTY

D

LCOUTLET

CB

E

/2”18

LC

FittingsLC A

GJ

I

Shower H

Blocking(optional)

Shower Headand Fittings

LC

F

Header forOptionalDome

Blocking(optional)

B F Outlet andSupply Fittings

LC

ShowerLC

FittingsLC

A

I

B

ED

C

Shower Headand Fittings

LCHeader forOptional Dome F

H

GJ

ShowerLC

Blocking(optional)

AI

FittingsLC

E

BD

COutletCL

J

Spout

Figure 7 Figure 8

Figure 9

11

13”

13”1”4

13”

Required forG 6036.72

4PRINTED IN U.S.A.Spec No. 2049 REV: 12/18/06.

www.ellasbubbles.com Page 7 10/17

Page 12: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6
Page 13: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

Ella Accessible Shower In A BoxWarranty Information

For all customers of private labels who complete the Ella’s Bubbles Product Registration Form and return the same to the Ella’s Bubbles Corporate Office, Ella’s Bubbles will use its best efforts to facilitate any customer warranty claim. Accordingly for any warranty claim brought to Ella’s Bubbles, terms and provisions written under the original manufacturer warranty shall to the extent reasonably possible be managed through Ella’s Bubbles to provide direct support and service to the consumer. The original manufacturer’s warranty is stated below:

Units manufactured of fiberglass reinforced polyester resin, that it will, free of charge, repair any Ella’s unit found to be defective in material or workmanship upon inspection by an authorized representative of Ella’s for a period of thirty (30) years from the date of purchase of the unit by a qualified professional. The exchange of a unit is limited to supplying a replacement unit of comparable size and style and does not include any cost of removal or installation. Any component part supplied by Ella’s carries the same limited warranty provided by our supplier for a period of one (1) year. Any Ella’s product will carry a thirty (30) year limited warranty against manufacturing defects. This warranty shall be voided if the unit is moved from its place of initial installation or is not installed in accordance with the instructions supplied by the manufacturer of the unit. Further, this warranty does not apply if the unit has been subjected to accident, abuse, misuse, damage caused by flood, fire, or act of God. The owner agrees by use of the unit that the obligations of Ella’s Bubbles, LLC. shall not exceed to contingent or indirect damage or injury to the structure of its contents, that the obligations of Ella Walk in Baths are limited to those set forth herein, and that no other obligations, expressed or implied, are assumed by Ella’s Bubbles.

All mailing notification must be sent via certified mail to: Ella’s Bubbles, LLC.

2101 S. Carpenter Street Chicago, IL 60608

Email: [email protected]

Page 14: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6
Page 15: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

Warranty Activation Form 1 of 2

INSTALLER'S INFORMATION

_______________________________________________________________________________________ Name

_______________________________________________________________________________________ Address City State Zip

_________________________________ _________________________________________________ Telephone Email

_________________________________ _________________________________________________ Date Signature

Upon completing the installation of an Ella Walk In Tub, the following Warranty Activation Form must be completed, signed by both the customer and installer, and returned to Ella’s Bubbles, LLC. In order for the Warranty to be activated (faxed, scanned, or emailed, or hard copy mailed).

To be initialed by the installer(s)

____Tub is level in all directions and all support legs are touching the ground. ____Tub is installed on a dedicated 30 Amp GFCI protected circuit using 10 gauge wire ____Frame of the tub has been properly grounded. ____ Door Seal has been cleaning with rubbing alcohol to remove any dust or debris left

over from construction. ____Temperature Control Valve operated on both hot and cold settings. ____Both diverters function properly. ____Hand Shower functions on all settings without leaking. ____All supply lines have been checked for leaks while both diverters are on. ____ Drains open and close properly, and the locking nut has been tightened on both

stoppers. ____Door seal is water tight after tub has been filled for a minimum of 20 minutes. ____ After running for a minimum of 20 Minutes both the Hydro and Air Pumps are

functioning properly and all connections to the pumps and jets are water tight. ____ Chromatherapy Light and the Ozone Sterilization are working properly. (When the

Ozone is on by itself it will make a light humming noise). ____All drain fittings have been checked for leaks while the tub is draining. ____Unit is installed with access to both plumbing and electrical connections.

www.ellasbubbles.com Page 23 10/17

Page 16: ELLA LOW THRESHOLD APPLIED ACRYLIC SHOWERS OWNER'S …€¦ · shower as a trash receptacle! Always place a drop cloth or cardboard on the floor when working inside the shower. 6

Warranty Activation Form 2 of 2

OWNER'S INFORMATION

_______________________________________________________________________________________ Name

_______________________________________________________________________________________ Address City State Zip

_________________________________ _________________________________________________ Telephone Email

_________________________________ _________________________________________________ Date Signature

Model: ___________________________________ Serial Number: ______________________________

Purchase Date: ___________________________ Purchase Price: _____________________________

Place of Purchase: _____________________________________________________________________

Contact Name: ___________________________ Phone Number: _____________________________

Copy of sales receipt must be included with warranty activation forms.

To activate manufacturer's warranty, please complete both pages and use one of the options below to submit.

Via mail: Ella's Bubbles, LLC. Warranty Department 2101 S. Carpenter St., Chicago, IL 60608

Via fax: 1-312-666-3551

Via email: [email protected]

www.ellasbubbles.com Page 24 10/17