Dynamic modelling of the steam generation system in the HPS2 CSP molten salt trough test facility Prepared by: Robert Temlett Supervisor: Prof Pieter Rousseau 13/07/17

Upload: others

Post on 03-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Dynamic modelling of the steam generation system in the HPS2 CSP molten salt trough test facility

Prepared by: Robert Temlett

Supervisor: Prof Pieter Rousseau

13/07/17

Page 2: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

4-Aug-17 2

Introduction

• HPS2 is a Parabolic CSP (Concentrated Solar Power) test facility, where molten salt is being used as the heat transfer fluid.

• Advantages: • Plant simplification (Reduces cost due to less components)

Chiyoda Corporation. https://www.chiyoda-corp.com/technology/en/green_energy/solar_energy.html

Page 3: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Introduction

• HPS2 is a Parabolic CSP (Concentrated Solar Power) test facility, where molten salt is being used as the heat transfer fluid.

• Advantages: • Plant simplification (Reduces cost due to less components). • Higher heat transfer fluid temperatures which leads to higher steam cycle

efficiencies. • Molten salt has a lower cost, non flammable. • Solar field is decoupled from the steam cycle.

• Disadvantages: • Molten salt has a high freezing temperature. • Corrosive at high temperatures.

• How to manage risks: • Operational strategy should be able to reduce the risk of freezing. • Using corrosive resistant materials will reduce the risk of corrosion.

4-Aug-17 3

Page 4: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Introduction to the masters project

• The main objective is to create a dynamic process model of the molten salt storage system combined with the steam generator and cooling system in Flownex.

• Benefits of having a dynamic model: • Provides an understanding of the transient response of the test facility. • Pre-tune control loops for the test facility.• Train the plant operators.

4-Aug-17 4

Page 5: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Water/Steam Cycle

• Main components: • Helical Coil Economizer and Evaporator.• Separator (only used in start up).• Two straight tube super heaters. • Series of valves to bring steam temperature and pressure down. • Air cooled condenser.

4-Aug-17 5

Page 6: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Flownex Modelling Approach

Flownex Simulation Environment:• Integrated system modelling code used for design, simulation and

optimization of complete thermofluid systems. • System is discretized into spatial or conceptual volumes in one

dimension for which mass, momentum and energy are solved.• Two phase regions are modelled using a homogeneous approach.• Helical coil simplification:

4-Aug-17 7

𝜃𝜃

Page 7: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Heat Transfer Correlations Used

• In the economizer section of the helical coil steam generator, the Reynolds numbers achieved by the flow under different plant loads are represented well by the following Nusselt number:

𝑁𝑁𝑁𝑁 = 0.328𝑅𝑅𝑅𝑅0.58𝑃𝑃𝑃𝑃0.4

6000 < 𝑅𝑅𝑅𝑅 < 180,000• For the evaporator section the Reynolds number is always greater

than 1.9x105 and thus the standard straight tube Dittus-Boelter equation was used.

• The molten salt flow over the helical coil is assumed to be cross flow and thus a correlation for cross flow over tube banks was used.

• For the superheaters the standard Dittus-Boulter equation for the steam on the tube side was used.

• For the superheaters the following correlation was used which was developed for single phase heat transfer on the shell side.

𝑁𝑁𝑁𝑁 = 0.2𝑅𝑅𝑅𝑅0.6𝑃𝑃𝑃𝑃0.33(𝜇𝜇𝜇𝜇𝑤𝑤

)0.14

4-Aug-17 8

Page 8: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Frictional Losses

• For the helical coil tube side a standard straight tube pressure correlation is used with a multiplication factor added to enhance the pressure drop seen in the helical coil.

• For the shell side in the helical coil steam generator and the super heaters a flow resistance element was used, where the equation for the pressure drop is given below. The flow admittance is adjusted to give expected pressure drops from design values at 100% load.

∆𝑝𝑝0 =|�̇�𝑚|�̇�𝑚

𝜌𝜌𝐴𝐴𝑓𝑓𝐴𝐴𝑠𝑠𝑓𝑓𝐴𝐴0+ 𝜌𝜌𝜌𝜌∆𝑧𝑧

Where:𝐴𝐴𝑓𝑓 = 𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓 𝑎𝑎𝑎𝑎𝑚𝑚𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑅𝑅

𝐴𝐴𝑠𝑠𝑓𝑓 = 𝑎𝑎𝑎𝑎𝑚𝑚𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑎𝑅𝑅 𝑠𝑠𝑎𝑎𝑎𝑎𝑓𝑓𝑎𝑎𝑎𝑎𝜌𝜌 𝑓𝑓𝑎𝑎𝑎𝑎𝑎𝑎𝑓𝑓𝑃𝑃𝐴𝐴0 = 𝑓𝑓𝑝𝑝𝑅𝑅𝑎𝑎𝑎𝑎𝑎𝑎𝜌𝜌

4-Aug-17 9

Page 9: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Flownex Model For Each Component

4-Aug-17 10

Economizer/Evaporator Superheater

Page 10: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Flownex Model of Components Connected

4-Aug-17 11

Superheater 2Superheater 1Economizer/Evaporator

Page 11: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Steady State Results For Each Separate Component

4-Aug-17 12

Economizer Evaporator Superheater 1 Superheater 2

Salt outlet Temperature

-0.49% -0.66% +1.17% +0.98%

Salt Outlet Pressure

+1.3% +1% -0.654% -0.26%

Water/steam outlet

temperature

+0.17% +6.05% -0.269% -0.78%

Water/steam outlet

pressure

-0.19% +0.8% +0% +0.34%

• Table below shows the results as a percentage error against expected results obtained from the design description and operating manual, for each component tested separately at 100% load.

Page 12: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Steady State Results For Whole Steam Generation Section

4-Aug-17 13

Plant Load: 35% 100% 115%

Salt Exit Temperature

+7.3% +3.09% -2.04%

Steam Exit Temperature

+0.06% +2.74% +2.87%

Steam Pressure

-16.85% -57.25% -75%

• Table below shows the results as a percentage error against expected results obtained from the operating manual, for the entire steam generation system.

Page 13: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Economizer Sub Element Results

4-Aug-17 14

Page 14: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Operating Condition Adjustments

4-Aug-17 15

Plant load: 35% 100% 115%

Salt mass flowrate

0% -0.53% -3.4%

Water/Steam mass flowrate

+6% +9.7% +13.6%

Feed water pressure

0% +0.625% +0.6%

Page 15: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Steady State Results With Adjusted Operating Conditions

Plant Load: 35% 100% 115%

Salt Exit Temperature

+2.15% -1.95% -2.38%

Steam Exit Temperature

-0.12% -0.16% +0.62%

Steam Pressure -3.42% -0.28% -4.085%

4-Aug-17 16

• Table below shows the results as a percentage error against expected results obtained from the operating manual, for the entire steam generation system after operating conditions were adjusted.

Page 16: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Transient Results

4-Aug-17 17

-40

-30

-20

-10

0

10

0 200 400 600 800 1000 1200 1400 1600 1800

% D

iffer

enec

Time (s)

Temperature % vs Time 35%-100% load

Eco/Evap Exit Super Heat outlet Salt Outlet

-80

-60

-40

-20

00 200 400 600 800 1000 1200

% P

ress

ure

Diff

eren

ce

Time (s)

Pressure % difference vs time 35%-100% load

Eco/Evap Outlet Superheater outlet Eco Outlet

• % difference against a reference temperature or pressure.

• Eco/Evap and Superheater outlet reference temperature was the expected outlet temperature of the outlet of superheater 2.

• Salt outlet temperature was referenced against the expected salt outlet temperature.

• Pressure was referenced against the feedwater inlet pressure.

Page 17: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Transient Results

4-Aug-17 18

-40-35-30-25-20-15-10

-505

10

0 500 1000 1500 2000 2500

Perc

enta

ge T

empe

ratu

re

Time (s)

Temperature 5 difference vs time 100%-35% load

Eco/Evap outlet SuperHeat Outlet Salt Outlet

-50

0

50

100

150

0 500 1000 1500 2000 2500

% P

ress

ure

Time(s)

Pressure % difference vs time(s) 100%-35%load

Eco/Evap Outlet Super Heater Outlet Eco Outlet

• % difference against a reference temperature or pressure.

• Eco/Evap and Superheater outlet reference temperature was the expected outlet temperature of the outlet of superheater 2.

• Salt outlet temperature was referenced against the expected salt outlet temperature.

• Pressure was referenced against the feedwater inlet pressure.

Page 18: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Conclusions

• For each separate component the model produces results which correlate well with expected results.

• Unexpected large pressure drops for the whole steam generation system is due to the boiling point in the helical coil steam generator.

• Small changes in the operating conditions move the boiling point further up the helical coil steam generator significantly, thus reducing the pressure drop.

• Decreasing the salt mass flowrate and increasing the water/steam mass flow rate moves the boiling point up.

• Final outlet temperature of the steam generation system does not fluctuate by much through transient scenarios.

• Temperature outlet of the salt changes quickly and there is a lag in response.

4-Aug-17 19

Page 19: Dynamic modelling of the steam generation system …sterg.sun.ac.za/wp-content/uploads/2017/03/R_Temlett.pdfDynamic modelling of the steam generation system in the HPS2 CSP molten

Questions

4-Aug-17 20