1 2 3 4 5 6 7 8 9 1 Trim the segments that are to be duplicated to a tapered form; this allows easier later removal from the silicone mould. 2 Remove all parts except those dies that are to be duplicated. Fit the Giroform base plate to the duplicating flask and close the swivelling fasteners on the underside. 3 Adjust the partitioning bar. Place two pins outside the duplicating area (Blockpin - Art. No. 561451), move the partitioning bar into contact with the pin and fasten the locking screw. Fill the empty pinholes with wax. 4 Pour the duplicating silicone into the flask and allow to set according to the manufacturer’s instructions. ATTENTION: Use silicone with low Shore hardness (approx. 20), as this will ensure easier removal of the dies. 5 Unfasten the base plate; remove the dies from the mould. 6 Cut a drainage channel in the Giroform base plate to allow refractory die material to escape. 7 Place refractory pins (576480) or tapered double- ended pins (576490) in the base plate. Fill the duplicating flask with the refractory die material. 8 Fit the base plate, close the fasteners, and allow to set according to the manufactur- er’s instructions. 9 Further processing and preparation of the refractory dies should be made in accor- dance with the porcelain manufacturer's instructions. Model fabrication 1 Put a secondary plate onto the finished Giroform model. 2 Apply articulating plaster onto the model and onto the articulator side. Close the articulator without pressure. 3 The result: a precise and neatly sawed model in the articulator. MOUNTING ALTERNATIVE I | Secondary plate 1 3 2 MOUNTING ALTERNATIVE II | Magnet + Socket 1 Block out the pin tips with putty. 2 Put a space retainer foil in the center and fix it with mag- nets. 3 Apply plaster onto both sides and close the articulator without pressure. 1 3 2 1 Set 3 pins into the model plate. 2 Block out the pin tips with putty, put a space retainer foil on it. 3 Apply plaster onto both sides and close the articulator without pressure. 1 3 2 MOUNTING ALTERNATIVE III | Setting pins (Giroform Classic) DUPLICATING IN THE GIROFORM-SYSTEM The burr rests on a slotted screw in the center of the axis. Clockwise turns lower the screw = tighter drill hole; counter-clockwise turns raise up the screw = wider drill hole. The wider the drill hole, the farther the pin tip juts out of the plinth plate. 1 1 2 1+2 Unplug the power cable. Insert the fixing pin from the side into one of the holes of the drilling axis. Turn the tubular socket wrench in counter-clock- wise direction to unscrew the sleeve nut. Then, remove the defective burr. 2 ! # @ # 3 ADJUSTING THE DRILLING DEPTH REPLACING THE BURR Herrschaftswiesen 1 6842 Koblach | Austria Fon +43 5523 62333-0 Fax +43 5523 55990 12169 Villa Rd. Spring Hill, Florida 34609 | USA Call Toll-Free: 1-800 851 3719 Fax: +1 941 721 3411 [email protected] [email protected] [email protected] www.amanngirrbach.com Amann Girrbach GmbH Dürrenweg 40 75177 Pforzheim | Germany Fon +49 7231 957-100 Fax +49 7231 957-159 ! allen screw 2.5 mm @ Fixing screw # metal pin To adjust the fixing pressure that holds the Giroform plinth plate in its place, the allen screw (2.5 mm) is turned in counter- clockwise direction to reduce the spring pressure; if turned in clockwise direction, the spring pressure increases.

Upload: nguyencong

Post on 31-Mar-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

1 2 3 4 5

6 7 8 9

1 Trim the segments that areto be duplicated to a taperedform; this allows easier laterremoval from the siliconemould.

2 Remove all parts exceptthose dies that are to beduplicated.

Fit the Giroform base plate tothe duplicating flask and closethe swivelling fasteners onthe underside.

3 Adjust the partitioning bar.Place two pins outside theduplicating area (Blockpin -Art. No. 561451), move thepartitioning bar into contactwith the pin and fasten thelocking screw.

Fill the empty pinholes withwax.

4 Pour the duplicating siliconeinto the flask and allow to setaccording to the manufacturer’sinstructions.

ATTENTION: Use silicone withlow Shore hardness (approx.20), as this will ensure easierremoval of the dies.

5 Unfasten the base plate;remove the dies from themould.

6 Cut a drainage channel inthe Giroform base plate toallow refractory die materialto escape.

7 Place refractory pins(576480) or tapered double-ended pins (576490) in thebase plate. Fill the duplicatingflask with the refractory diematerial.

8 Fit the base plate, close thefasteners, and allow to setaccording to the manufactur-er’s instructions.

9 Further processing andpreparation of the refractorydies should be made in accor-dance with the porcelainmanufacturer's instructions.

Model fabrication

1 Put a secondary plate ontothe finished Giroform model.

2 Apply articulating plasteronto the model and onto thearticulator side. Close thearticulator without pressure.

3 The result: a precise andneatly sawed model in thearticulator.

MOUNTING ALTERNATIVE I | Secondary plate

1 32

MOUNTING ALTERNATIVE II | Magnet + Socket

1 Block out the pin tips withputty.

2 Put a space retainer foil inthe center and fix it with mag-nets.

3 Apply plaster onto bothsides and close the articulatorwithout pressure.

1 32

1 Set 3 pins into the modelplate.

2 Block out the pin tips withputty, put a space retainer foilon it.

3 Apply plaster onto bothsides and close the articulatorwithout pressure.

1 32

MOUNTING ALTERNATIVE III | Setting pins (Giroform Classic)

DUPLICATING IN THE GIROFORM-SYSTEM

The burr rests on a slottedscrew in the center of the axis.Clockwise turns lower thescrew = tighter drill hole;counter-clockwise turns raiseup the screw = wider drillhole. The wider the drill hole,the farther the pin tip juts outof the plinth plate.

1

1

2

1+2 Unplug the power cable.Insert the fixing pin from theside into one of the holes ofthe drilling axis. Turn the tubularsocket wrench in counter-clock-wise direction to unscrew thesleeve nut. Then, remove thedefective burr.

2

!#

@

#

3

ADJUSTING THE DRILLING DEPTH

REPLACING THE BURR

Herrschaftswiesen 16842 Koblach | AustriaFon +43 5523 62333-0Fax +43 5523 55990

12169 Villa Rd.Spring Hill, Florida 34609 | USACall Toll-Free: 1-800 851 3719Fax: +1 941 721 3411

[email protected]@[email protected]

Amann Girrbach GmbH Dürrenweg 4075177 Pforzheim | GermanyFon +49 7231 957-100Fax +49 7231 957-159

! allen screw 2.5 mm

@ Fixing screw

# metal pin

To adjust the fixing pressurethat holds the Giroform plinthplate in its place, the allen screw(2.5 mm) is turned in counter-clockwise direction to reducethe spring pressure; if turnedin clockwise direction, thespring pressure increases.

1 Trim all unnecessary partsof the impression (reflection,palatal roof) in order to obtaina dental arch which is as lowas possible but still stableenough.

NOTE:Heating of the blade facilitatestrimming of extremely viscouspolyether materials (Impregum,Permadyne, etc.).

2 Position the impressiontray in the dorsal area on atransversal rim and in thearea of the tray handle on acube sized 2 x 2 cm, both outof Giroform Putty (576461).

3 Insert the dove tail of theclear adjustment plate - withsplit retention looking upwards -into the groove of the carrierand guide it downwards.

1 Insert the plinth plate intothe plate support from thebottom. First, press the frontalgroove of the plinth plateagainst the spring bolt; thenthe have the dovetail engageat the opposite side. Tightenthe fixing screw by hand.

2 Position the carrier with theimpression on the plate support.

3 Both metal nozzles on topof the plate support clutch thetwo drill holes of the impressioncarrier.

4 Place the plate supportwith impression carrier ontothe magnetic table.

5 Turn the unit on at themain switch at the unit's front(a green control is lit). Activatethe laser by pressing either

one of the triggers.Align/determine the drillingposition by means of the laserbeam.

NOTE:The laser automatically shutsoff 2.5 min after the unit wasused last.

6 Pressing of both triggersat the same time automaticallyfixes the plate reception andinitiates the drilling process.

ATTENTION:The laser beam must be withinthe dimensions of the Giroformplinth plate. If the laser beam(= drilling position) is alignedoutside the dental arch, i.e. inthe area of the plate holderor of the retention disc, theburr might break.

Press the impression tray ontothe putty. Make sure that thesplit retention looks upwardswhen positioning the adjust-ment plate. Insert the dove tailof the clear adjustment plateinto the groove of the carrierand guide it downwards whilealigning the impression withthe center line, with the occlusalplane, and with the vestibulardimension of the later dentalarch in relation to the plate size.

4 By manipulating the puttyrim and/or cube, the impres-sion is aligned with the dorsalpart of the impression carrier.

TIP:Place the clear adjustmentplate with inserted pin on thealigned impression to checkthe height of the dental arch.The retention tip of the pin

STEP 1 | Placement of the Impression

1 2 3

1 2 3

4

5

4

6

STEP 2 | Drilling

STEP 3 | Casting and working

STEP 4 | Sawing of the Modell

Model fabrication

Laserbeam

Trigger5

should not touch the impres-sion (distance: approx. 3 mm).

5 Mark the saw cuts anddrill holes for the pins on theimpression material. Eachremovable segment has to befurnished with 2 pins (rotation!).Tip: In case of ill spatial condi-tions, set only 1 pin and mill aguidance groove into the plate.

IMPORTANT:Plan all adjacent teeth assingle segments since theexpansion of a long row ofadjacent teeth limits theapproximal area.

1 2 3 4

86 9

12 14

16

13 15

17

5

7 10

11

1 Place the Giroform plinthplate, with split retention loo-king downwards, in your hand.Hold the pins at the retentiontip, and push the tapered partinto the drill hole.

TIP:Friction depends on the forcesapplied when inserting the pin.(Push it in with your thumb;"pricking" indicates that bothplayless friction and removablereposition of the pin are ensu-red.)

2 Cover the MB thread holein the center with Giroformputty to protect it against pla-ster mush.

3 Put the Giroform plinthplate furnished with pins onthe impression to check if theplate flatly rests on the putty.

Spray a separating agent onthe impression, then rinse it.Mix super stone in the appro-priate mixing ration andunder vacuum.

4+5 Pour the plaster mushinto the impression preventingbubbles (the use of a vibratoris highly recommended). Whenall teeth and the preparationarea are completely covered,take the impression carrier fromthe vibrator and fill the impres-sion above the brim with plaster.

6+7 Apply plaster on thepins' retention tips and on therest surface of the plinth platein the area where the dentalarch will be located. Positionthe plate in the dove-tail gui-dance and lower it into theplaster mush until the platerests planely on the putty.

IMPORTANT: Do not applyplaster to the plate whilethe vibrator is on since thepins will become loose.

8+9 Detach after 20 ormax. 35 min by removing thevestibular putty sleeve. Then,lift off the impression fromthe impression carrier.

10+11 Divesting: Put theblade tip of a plaster knifebetween the impression andthe plaster. The model is liftedout of the impression by tur-ning the blade. Therefore, theback of the blade rests on thetray rim, and the tip of theplate levers the model out ofthe impression.

IMPORTANT:Do not exceed the maximaldivesting time of 35 minsince otherwise irreparabledimensional deviations occurdue to the plaster expansion,thus resulting in a high riskof breaking the dental arch.

12+13 Place the model flat inyour hand with the split reten-tion looking downward, hit itwith a hammer on the dorsalarea of the plate until thedental arch comes off.

14+15 Then, dry trim the den-tal arch in the vestibular andpalatal area with the Multitrimunit (115800).

16+17 As an alternative todry trimming and for finishingpurposes, a handpiece may beused furnished with mandrel(815300) and arbor band -grit 120 (815330).

1 2 3 4 5 1 Reposition the trimmeddental arch on the plinth platewithout applying pressure.Between the dental arch andthe plinth plate a gap of approx.2 mm is visible resulting fromthe plaster expansion. Theadvantage is that you see thepins when sawing.

2+3 Fix the plinth plate inthe model table of the Diacutmodel saw (171800). Align themodel table in accordancewith the cutting direction. Thesaw cuts as defined.

4 The linear expansion stress

resolves; the segment dropsonto the plate and rests tightly.

TIP:Cut the dental arch in halvesfirst and remove one half soyou can effect the saw cutswith less hindrance. Thus, theopposing side of the dentalarch is protected form gettingharmed.

5 Clean all segments andreposition them tightly on thecleaned plinth plate.