  • 8/12/2019 Dse501 Installation Instructions

    1/2

    The Model 501K-1 is a ManualEngine Control Module, whichhas been designed to manuallycontrol the engine via a keyswitch on the front panel. Themodule is used to start and stopthe engine, indicating faultconditions; automatically shuttingdown the engine and indicatingthe engine failure by LED givingtrue first up fault annunciation.

    Operation of the module is via athree position key switchmounted on the front panel withSTOP(O), RUN(I) and START(II)positions. In the O position theDC supply is removed from themodule and the run relay andalarm output are de-energised. Ifthe switch is turned to the I

    position the module is poweredup and the run relay is energised,activating the engine fuel/ignitionsystem and the protection hold-off timer is initiated. If the switchis moved to the II position andheld against the spring return, apositive supply is applied to therelevant output terminal and on tothe starter motor. Once theengine has started the switchshould be released and allowed

    to return to the I position.

    Operation of any of the followingalarms; Low Oil Pressure, HighEngine Temperature, AuxiliaryShutdown, Overspeed(Optional), will cause the runrelay to de-energise. This willremove the fuel/ignition supplyfrom the engine and bring it torest. The alarm output will beactivated giving a positive DC

    output.

    Each alarm channel has its ownLED indicator and once activatedno further alarm conditions will beaccepted. The alarm output andrelevant LED will remain activeuntil the unit is reset by turning theswitch to the O position.

    Overspeed Protection (Optional)is achieved by the fitment of an

    additional PCB in the module. Thisprovides integral overspeedprotection derived from either thegenerator HZ output or the enginemagnetic pick-up (specified onordering). The overspeed circuitcontinuously monitors the enginespeed and will shut down theengine immediately if a pre-setspeed level is exceeded. This triplevel is adjustable from 90% to130% of full rated speed and issuitable of both 50Hz or 60Hzsystems.

    During engine cranking and for ashort time afterwards theprotection hold-off timer is activeand the relevant alarms inputs areinhibited. This enables the engineto start and achieve normal runningconditions. Once the timer hasexpired the inputs are enabled

    providing normal protection fromthe module.

    Charge Failure warning is alsoprovided by monitoring the WLterminal on the charge alternator.This operates on a similar principalto the warning lamp fitted in amotor vehicle, should the outputfail the charge fail LED willilluminate. The module will alsoprovide the alternator excitation

    current via this connection.

    DESCRIPT ION

    SPECIF ICATION

    DC Supply:

    9 to 33 V Continuous.Cranking Dropouts:

    Able to survive voltage dips duringcranking.This is achieved withoutthe need for internal batteries.Alternator Input Range:

    15 - 305 V AC RMSAlternator Input Frequency:50 - 60 Hz at rated engine speed.Magnetic Input Range:

    0.5 V to +/- 80 VMagnetic InputFrequency:2300Hz to 6000 Hz atrated engine speed.Start Relay Output:

    16 Amp DC at supply voltage.Run Relay Output:16 Amp DC at supply voltage.Alarm Output:1 Amp DC at supply voltage.

    Dimensions:

    72 X 72 X 118.5 (Excluding Key-switch)Operating Temperature Range:-30 to +70CInstallation:Front panel mounting via suitablecut-out. Retaining clips supplied.Cable connections via locking plugand socket type connectors.Calibration:Speed trip setting and metercalibration adjustmentpotentiometer are accessible fromthe rear of the module.

    Issue 105/01

    Deep Sea Electronics plc maintains a policy of continuous development and reserves the right to change the details shown in this data sheet without priornotice. The contents are intended for guidance only.

    DEEP SEA ELECTRONICSPRODUCT:DSE501KManual Start053-045

  • 8/12/2019 Dse501 Installation Instructions

    2/2

    CASE DIMENSIONS

    72.0mm

    72.0mm

    65.5mm

    111.0mm

    7.5mm

    Panel Cut out: 68mmx68mm

    1

    10

    11

    14

    Meter

    Trip

    TYPICAL CONNECTIONS

    Deep Sea Electronics Plc.Tel:+44 (0)1723 890099

    Fax: +44 (0)1723 893303LO CALL (from UK BT landlines) :

    Telephone 0845 260 8933

    Email: [email protected]: www.deepseaplc.com

    Deep Sea Electronics inc.Phone: +1 (815) 316-8706

    Fax: +1 (815) 316- 8708

    TOLL FREE (USA only) : Tel: 1

    866 636 9703

    Email: [email protected]

    Web: www.deepseausa.com

    Deep Sea Electronics Plc.(Far East)

    Tel:+66 2 670 6228Fax: +66 2 678 3028

    Email: [email protected]: www.deepseaplc.com