dqhds upgrade: status of hardware design. approach to implementation of the new heater measurement...

11
DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011 V. Froidbise

Upload: james-perry

Post on 05-Jan-2016

217 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

DQHDS Upgrade: Status of Hardware Design.

Approach to implementation of the new heater measurement system.

08/06/2011

Page 2: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

Summary

• Requirements• Principles of measurements• Implementation: modifications in situ• New DQLPU crate• Status

08/06/2011

Page 3: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

Requirements

1. Current discharge recording during a quench.2. Measurement of resistance value of the

heaters, periodically.

08/06/2011

Page 4: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

1st principle of current discharge measurement

08/06/2011

Output stage of DQHDS

U_HDS

Hea

ter

+-

Shunt

Page 5: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

2d principle of current discharge measurement:

08/06/2011

Output stage of DQHDS

U_HDS

Hea

ter

Advantages of the Pulse transformer, called: « Broad-Band Current –Pulse Transformer ».Shielded – Ferrite-Core :

•Galvanic isolation•Maintain of the continuity in the wire•Less noisy

+-

Page 6: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

With measurement of resistance value of the heaters

08/06/2011

Output stage of DQHDS

U_HDS

Hea

ter

+-

Constraint: create two connections in the discharge circuit

+-

Page 7: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

Principle schematic of current source

08/06/2011

Page 8: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

« Crawford box »

08/06/2011

Page 9: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

Modifications or design a new connection box?

08/06/2011 V. Froidbise

6 cm8 cm

Page 10: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

DQLPU

08/06/2011

Power supply DQQDL_A DQQDL_B DQAMC

FIP

Future Electronics in the DQLPU:

New motherboard + commutation Relays

DQAMC DQQDL_A DQQDL_BCurrent sources+

heaters measurement

Current discharge

measurement

Lateral heat sink

Linear Power SupplySwitching Power Supply

Page 11: DQHDS Upgrade: Status of Hardware Design. Approach to implementation of the new heater measurement system. 08/06/2011V. Froidbise

V. Froidbise

What is today’s status – and outlook?

• Tests for DQHDS discharge current through a shunt already validated, but sampling frequency must be adapted.

• Waiting for a sample of a toroidal pulse transformer before performing tests and validation (Knud).

• Integration into the existent Crawford box will be envisaged after discussions with RP to see where and what might be done. Reliability of the contact taps needed must be done without weakening of the discharge circuit appropriated connections.

• Simulation/Measurement of a defect in a heater strip validated in a DC method (see Reiner’s presentation and Joaquim’s tests).

• Prototype of a precision current source is under tests, looks promising.• New developments of 3 electronics cards: a motherboard, a heater

resistance measurement board (4 circuits / dipole) and a heater discharge current measurement board.

• Probably a new crate DQLPU: easier to operate.

08/06/2011