DS-DPGUARD-EN_2-3 1/2 Rev. 2.3 FAUDI Aviation GmbH Scharnhorststrasse 7 B D-35260 Stadtallendorf Germany Phone: +49 6428 4465-275 Fax: +49 6428 4465-231 E-Mail: [email protected] Web: www.faudi-aviation.com SENSOR TECHNOLOGY DPGUARD ® FAUDI Aviation DPGUARD ® is a fully au- tomated touch screen operated calcula- tor to give out the corrected differential pressure across the filter elements (Mo- nitor filters or Coalescers) in mobile or fixed filter vessels being operated at less than maximum rated flow. The DPGUARD ® automatically calcu- lates the condition of the filter elements inside the vessel using the signal in- puts of flow rate and differential pressu- re across the elements. It monitors the changing condition of the elements and provides a history (Oscillograph) so that element change times can be anticipated and abnormal conditions could be de- tected. It gives out the overall throughput (flow volume during lifetime) of the ele- ments. It does a continuous differential pressure check calculating the corrected differential pressure, logging it and com- paring the results against previously calculated numbers. If things are going wrong – Alarm functionality behind can be addressed to automatically stop the fuelling process without further interaction. The system based upon the related joint standards as described in EI 1581, EI 1583, EI 1590 and EI 1596. Applications Page 0 300 600 900 1200 1500 100 90 80 70 60 50 40 dp in new condition dp in contaminated condition dp real measured value dp (mbar) % of Flow end of life time start of life time Differential pressure values of monitor elements contaminated versus new elements Sample Graph

Upload: others

Post on 25-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DPGUARD SENSOR TECHNOLOGY · The DPGUARD ® catches up electrical signals from flow measurement (ana-logue input signals) and differential pressure measurement (one or two analogue

DS-DPGUARD-EN_2-3 1/2 Rev. 2.3

FAUDI Aviation GmbHScharnhorststrasse 7 BD-35260 StadtallendorfGermany

Phone: +49 6428 4465-275Fax: +49 6428 4465-231E-Mail: [email protected]: www.faudi-aviation.com

SE

NS

OR

TE

CH

NO

LOG

YDPGUARD®

FAUDI Aviation DPGUARD® is a fully au-tomated touch screen operated calcula-tor to give out the corrected differential pressure across the filter elements (Mo-nitor filters or Coalescers) in mobile or fixed filter vessels being operated at less than maximum rated flow.The DPGUARD® automatically calcu-lates the condition of the filter elements inside the vessel using the signal in-puts of flow rate and differential pressu-re across the elements. It monitors the changing condition of the elements and provides a history (Oscillograph) so that element change times can be anticipated and abnormal conditions could be de-tected. It gives out the overall throughput (flow volume during lifetime) of the ele-ments. It does a continuous differential pressure check calculating the corrected differential pressure, logging it and com-paring the results against previously calculated numbers. If things are going wrong – Alarm functionality behind can be addressed to automatically stop the fuelling process without further interaction.The system based upon the related joint standards as described in EI 1581, EI 1583, EI 1590 and EI 1596.

Applications

Page

0

300

600

900

1200

1500

100908070605040

dp in new conditiondp in contaminated conditiondp real measured value

dp (m

bar)

% of Flow

end of life time

start of life time

Differential pressure values of monitor elements contaminated versus new elements

Sample Graph

Page 2: DPGUARD SENSOR TECHNOLOGY · The DPGUARD ® catches up electrical signals from flow measurement (ana-logue input signals) and differential pressure measurement (one or two analogue

DS-DPGUARD-EN_2-3 2/2 Rev. 2.3

FAUDI Aviation GmbHScharnhorststrasse 7 BD-35260 StadtallendorfGermany

Phone: +49 6428 4465-275Fax: +49 6428 4465-231E-Mail: [email protected]: www.faudi-aviation.com

DPGUARD®S

EN

SO

R T

EC

HN

OLO

GY

Page

Status Alarm! (blinking)The corrected differential pres-sure is above the alarm limit (limit could be user defined in the configuration menu – in this case it is predefined to 1.5 bar)Alarm Status could be used to automatically stop fuelling pro-cesses due to Relay or digital output signal.

The main screen shows measured values like differential pressure and actual flow and gives out the calcu-lated differential pressure value. Three different function / alarm-level related screen colours are available.

The DPGUARD® catches up electrical signals from flow measurement (ana-logue input signals) and differential pressure measurement (one or two analogue signals) across the filter ele-ments. These signals are the main in-formation to calculate and give out the corrected differential pressure value. It does a continuous differential pres-sure check calculating the corrected differential pressure, logging it and comparing the results against previ-ously calculated numbers. If things are going wrong – Alarm functionality behind can be addressed to automati-cally stop the fuelling process without further interaction.

Function

Technical Details

Power Supply 24 VDC ±10%Memory Internal DataloggerSignal Transfer Ethernet; USB; LAN/WLAN

Signal In- /OutputsQty. Parameters

Digital Input 8 24 VDC ±10% 10 mADigital Output 8 24 VDC 500 mAAnalog Input 4 0...10 VDC / 0...20 mA / Pt 1000 12 BitAnalog Output 2 0...10 VDC 12 BitCounting Input 2 up to 5 kHz min. pulse step 0,1 ms

Status Warning!The corrected differential pres-sure is between user defined limits (predefined between … % and 100 % of corrected diffe-rential pressure) Warning levels could be user defined and could be used to address Relay or digital output for further action.

Status okThe corrected differential pres-sure as a mathematical calcula-tion is ok. The calculation based on internal calculation relation and could be self adjusted du-ring fully automated self lear-ning step.(Patent pending).