Worldwide Hydrogen FuelingStation and Vehicle Interface
StandardizationISO 19880-1
Jesse Schneider, BMW (ANSI Convener ISO WG24)
Guy Dang-Nhu, Air Liquide (co-chair ISO WG 24)Nick Hart, ITM Power (WG 24 Secretary ISO WG 24)
WG 24, ISO TC197 Presentation at ICHS 2015
-
ISO WG 24, TC 197: Hydrogen Station General Specification
• Goal: Develop the Worldwide Hydrogen Station and FCEV interface Standard, through ISO 19880-1 by end of 2016 to support infrastructures (and EU Directive).
• Team: Global Collaboration with International OEMs, Fuel Providers, Oil Companies, Infrastructure and Vehicle Partnerships, Local and National Government Representation, and from US, Japan, EU and China
-
SAE INTERNATIONAL
3
Worldwide hydrogen Infrastructure
3
Europe: Germany• Demo-project Clean Energy Partnership
15 public stations + 35 in process in 2016• 400 Privately funded in planning until 2023
EU50 EU Government funded in planning until 2023
Scandinavian Countries • Scandinavian Hydrogen Highway, • 10 public stations / 6 in process/ 15 planned for
2016+.
Japan• 100 stations planned until 2016+• 1000 stations in discussion until 2025
California / US• ZEV Mandate
10 public station, / • 45 more in process for 2016(100 Total planned)US/ East Coast• East Coast Hydrogen Highway
evaluation (TBD)
Fuel Cell Seminar: SAE Hydrogen Fueling Standards Training
Source: Jesse Schneider
-
SAE INTERNATIONAL SAE Hydrogen Fueling Standardization 4
Motivation for Hydrogen Fueling.Infrastructure Utilization
0
50
100
150
200
250
300
Gasoline Hydrogen Electricity
2000 km/day1250 Miles/day
240,000 km /day
150,000Miles/day
80,000 km/day50,000
Miles/dayRan
ge o
f o
ne
dis
pe
nse
r [1
03
km /
day
]
Potential ZEV Fuels
BEVSAE J1772 50KW Fast Charge
FCEV SAE J2601 T40 Refueling
HEV Gasoline Refueling
Source: Jesse Schneider
-
ISO 19880-1 Scope: Hydrogen Station Overview
Hydrogen production / delivery system Compression Gaseous hydrogen buffer storage; Pre-cooling device; Gaseous hydrogen dispensers. FCEV Vehicle Interface
-
ISO TR 19880-1 Overview
• General design & maintenance requirements
• Equipment & components
• Hydrogen and Electrical Safety
• Layout & safety distance description
• Safety Methodologies
• Fueling protocol & interface Hydrogen Dispenser FCEV Testing
• Quality control
• Alignment of Pressure Terminology and Values
-
ISO TC 197 WG 24Team Structure with subteams
WG 24 Management
Schneider (US), Dang-Nhu (FR)Hart (UK)
Hydrogen Station Acceptance
Moulthrop (US), Elliger (DE)
Hydrogen QualityControl
Tomioka (JP), Boisen(DK)
Safety DistanceMethodology
Flynn (FR), Groth (US)
Hydrogen Fueling ProcessRisk Assessment
Zimmermann (DE)
-
ISO 19880-1 Chapter 7,Hydrogen Fueling Diagram ©
-
Station Acceptance Checklists
Content: Consensus Criteria Internal to WG 24 + External References
HFS impact protection Example:
-
Station Acceptance TestingDevice Guidelines
- On-site “Field test” before normal operation of station- periodic - e.g. every year for verification of safety relevant PLC
HRS Performance
Hydrogen Gas Quality
Particle Measurement
Mass TransferMeasurement
Existing Standard No, Guidelines Yes (ASTM) Yes (ASTM) No, Guidelines
Goal to test orverify (parameter)
p, T in vehicletank
To collectsample gas
Particleidentification
Verification ofmass transfer
Safety relevant forinterface HRS-FCHV
YES No Yes Yes
min. requirement = part of ch. 12
YES YES YES YES
-
US “HyStep” HSTA ExampleSafety and Performance Testing
ISO WG 24 H2 Fueling Validation Workshop on
At ISO TC 197 Meetings in Torrance, CA
December 1st, 2015.
Example of Discussion:
Hydrogen Station Test Apparatus(From US DOE/Sandia/NREL)
Validating SAE J2601 Testing to All Categories:
• Three 77L Type IV Quantum tanks – 3.1 kg H2 capacity at 70 MPa NWP
• Allows for testing all SAE J2601– 3kg/6kg/9kg
Validating SAE J2799 Communications Test
12
-
ISO 19880-1 Annex B Testing with Hydrogen Station Test Apparatus
13
Dispenser function Tests F.A.T. S.A.T.
Confirmation that tables are correctly programmed into PLC through software means. Yes No
15 Fault Simulation Testing (see table B.2).
However Abort Signal to also be testing in both Factory Acceptance Tests (F.A.T.) and Site Acceptance Tests (S.A.T.)
Yes No
9 Field Tests on Site including 1-2 top off from low start pressure (see table B.3.3.4).
Verification that Measured Fueling performance Parameter are within limits Gas Temperature Window, Flow Rate and Pressure targets are within bounds of Fueling protocol
No Yes
Table B.1: Dispenser function tests
-
Informational: H2 Fueling & Quality Open Data Sharing Website with Reports
Ca. 1500 Views/600 Data Downloads and Official Release is 10/19!
-
Safety Methodology: H2 FuelingRisk Assessment
Lead: Lars Zimmermann (Germany) from Shell
-
ISO 19880-1 Pressure HarmonizationTable for fueling components
-
P-Member Survey results –Example: Status Clearance distances
-
Safety Distance Methodology:Quantitative Risk Assessment
Also See:
“HYRAM – a methodology and toolkit for quantitative risk assessment of hydrogen systems”
Example of a
risk-informed
approach to
safety distances
-
Status and Path Forward
• ISO TR 19880-1 passed P-Member ballot in October, 2015. Published in first quarter 2016
• ISO WG 24 is working to harmonize fueling validation with CSA, SAE & ISO and is working with the state of California.
• International Standard ISO 19880-1 Planned to finish by the end of 2016.
• ISO IS 19880-1 to be used as a basis for the European CEN H2 StationStandard which is planned to be used in the Alternative Fuels Directive(replacing ISO TS 20100).
• ISO 19880-1 is to be used as a basis for infrastructure in Europe includingthe 400 recently announced in Germany and 50+ European fundedstations starting in 2017- and other countries such as Japan, China, andreference in the US.
-
ISO 19880-1 Questions ?
Europe: Germany• Demo-project Clean Energy Partnership
15 public stations + 35 in process in 2016• 400 Privately funded in planning until
2023
Scandinavian Countries • Scandinavian Hydrogen Highway, • 10 public stations / 6 in process/ 15 planned
for 2016+.
Japan• 100 stations planned until 2016+• 1000 stations in discussion until 2025
California / US• ZEV Mandate
10 public station, / • 45 more in process for 2016(100 Total planned to 2020)US/ East Coast• East Coast Hydrogen Highway
evaluation (TBD)
(Hydrogen Fueling Infrastructure Developments)
-
Backup Slides
-
Fueling Components Updated Cycle Requirements
A fueling assembly should consist of a breakaway device, a hose(s), a nozzle and connectors between these components.
Suitability of the fueling assembly components for the specified service conditions and cycle life should be demonstrated by type testing. Type testing to enable a rated pressure to MAWP could for example include:
• a hydrostatic pressure test to 375 % NWP;• 100,000 pressure cycles to 125 % NWP; • 190 pressure cycles to 150 % NWP.
-
ISO TS 20100ISO 19880-1
Different Direction from previous ISO TS 20100:
• Detailed guidance on hydrogen dispensing. Reference SAE J2601 as possible means of fueling.
• More detailed guidance on the acceptance process (both safety and performance aspects)
• Study into variation of existing safety distances used currently around the world
Issues trying to address:
• Interaction between vehicle and dispenser – what is the minimum acceptable reliability of fueling control (Risk Assessment Approach).
• Understanding of Limits on dispensing pressures internationally, specifically the EU – what is needed to enable station side component filling of a vehicle 125 % NWP (not possible in EU currently). Goal to raise PRV setting to 138% NWP.
• Hydrogen quality – how to control quality without burdening stations with excessive, unnecessary analysis requirements (leading to creation of new WG 28 in ISO TC 197)
• Safety distances – status and trying to find consensus on an approach that is suitable for countries where there are currently very different methodologies in place
-
Dispensing Components and Fueling Protocol Pressure Mismatch
• Some fueling protocols go to a pressure of 125% during filling, however European dispenser components only rated to 125 % NWP.
• PRV needs to be set at the so-called “rated pressure” in Europe
• In the EU, this precludes fueling to 125 % NWP where PRVs are used as the over-pressure protection in case of the dispenser basic control system failure
-
Where ISO/ IEC references do not exist, WG24 has chosen select external references such as:
SAE• J2601 Fueling Protocols for Light Duty Gaseous Hydrogen
Surface Vehicles• SAE J2799 Hydrogen Surface Vehicle to Station
Communications Hardware and Software
ASTM• D7606-11 Sampling of High Pressure Hydrogen and Related
Fuel Cell Feed Gases• D7650-13 Standard Test Method for Sampling of Particulate
Matter in High Pressure Hydrogen
External Informative References
-
Example: D7650-13 Device in Use
Particulate Sampling DeviceD7680 70 Mpa Device (HYDAC) used in Germany
-
Example: D7606-11 Device in Use
HQSA Devices
CaFCP HQSA 35MPa DeviceCalifornia Fuel Cell Partnership
D7606 HQSA 70 MPa Device(California Weights and Measures)
Dispenser
Sampling
Adaptor
Sampling
Containers
Sample Collection
End Users
Analytical
Methods
D7606-11
http://papers.sae.org/2005-01-0002/
http://papers.sae.org/2005-01-0002/