Download - What is New in DesignBase 5.0 SP2
-
8/10/2019 What is New in DesignBase 5.0 SP2
1/60
W e l c o m e t o P a l a d i n D e s i g n B a s e
1
Po w e r A n a l y t i c s C o r p o ra t i o n
What is New in Paladin DesignBase5.0
Service Pack 2
Power Analytics Corporation
10805 Rancho Bernardo Road, Suite 270
San Diego, California 92127
U.S.A.
U.S. Toll Free Phone: 800-362-0603
Fax: 858-675-9724
www.PowerAnalytics.com
-
8/10/2019 What is New in DesignBase 5.0 SP2
2/60
What is New in Paladin DesignBase 5.0 SP2
2
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
Copyright 2014 Power Analytics Corporation. All rights reserved. Paladin, Power Analytics, Paladin DesignBase,
Paladin Live, Paladin SmartGrid, Paladin SmartGrid Power Management System, Paladin Gateway, Paladin
DesignView Paladin WSM, Pa ladin Solar, Intelligence in Rea l Time, and Foresight as Accurate as Hindsight and
their assoc iated logos and stylings, are pending or registered trademarks of Power Analytics Corporation. All
other trademarks, names, and logos are the property of their respec tive holders. Power Analytics gratefully
ac knowledges governmental and regulatory agencies whose names, photos, logos, award programs, or
certification programs are listed herein; such use does not c onstitute their endorsement of Power Analytics or its
products by these agenc ies.
Information in the document is subject to change without notice. The technology described in this document is
furnished under a license or nondisclosure agreement, and may be used or copied in accordance with the
terms of those agreements. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or any means elec tronic or mechanica l, including photocopying and recording for any
purpose other than the purchasers use without the written permission of Power Analytics Corporation.
Power Analytics Corporation
World Headquarters
10805 Rancho Bernardo Road, Suite 270San Diego, CA 92127
Phone: 858-675-9211
Fax: 858-675-9724
Power Analytics Corporation
Eastern United States
9208 Falls of the Neuse Road, Suite 215
Raleigh, NC 27615
919-848-6625
Fax: 919-848-5256
U.S. Toll-Free Phone 800-362-0603www.PowerAnalytics.com
IMPORTANT: Power Analytics Corporations software products are tools intended to be used by trained
professionals only. They are not substitutes for your professional judgment or for independent verification and
testing of results as they pertain to your specific application. Use of all Power Analytics Corporation software
products is governed by the terms and conditions of the End-User License Agreement (EULA) you accepted
when purchasing and installing the software. You must comply with these terms and conditions in applying the
instructional material in this manual. If you do not have or are unfamiliar with the contents of your EULA for this
software, you shouldrequest, read, and understand a copy of yourEULA before proceeding.
Please accept and respec t the fact that Power Analytics Corporation has enabled you to make an authorized
disk as a backup to prevent losing the contents that might occur to your original disk drive. DO NOT sell, lend,
lease, give, rent or otherwise distribute Power Analytics Corporation programs or User's Guides to anyone without
prior written permission from Power AnalyticsC orporation.
http://www.poweranalytics.com/http://www.poweranalytics.com/ -
8/10/2019 What is New in DesignBase 5.0 SP2
3/60
What is New in Paladin DesignBase 5.0 SP2
3
Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute
Dear Valued Customer:
Thank you for selecting Paladin DesignBase, the best design and modeling software
available today, and the only power system design software that allows your models to be
utilized in our Paladin Live solution.
You are joining a community of power system design professionals that support some of the
worlds most demanding mission-critica l fac ilities. Our Paladin family software is used to
Design, Model, Simulate, Analyze and Optimize power grids in a wide array of tec hnical
fields such as data c enters, critica l power applications such as off-shore oil platforms,
Federal government applications and the US Navy. We help ensure improved availability
and reliability, increased efficiency and improved throughput for companies such as
Boeing, Northrup Grumman, VISA International, Shell, Texas Instruments, Rolls Royce, Elf,
Alcoa and many other companies around the world who rely on Paladin DesignBase to
support their most important power systems designs.
Rec ent releases of Paladin DesignBase incrementally addressed customer requirements in
three primary areas:
1. Maximizing power systems designers personal productivity and ease-of-use.
2. Increasing capabilities for team-based design and the overall project.
3. Simplifying data management functionality between both DesignBase and third-party
programs, specifically in terms of allowing models to precisely encapsulate the robust data
required for on-line facility management using Paladin Live.
With Paladin DesignBase 5.0 Service Pack 2 we have continued this overall development
direc tion, while introducing new industry-leading capabilities in exciting areas, including:
A. Short Circuit Program
3 Phase Short Circuit fault buses selection option, either from drawings or from
memory
Added output CSV file for IEC 61363 detail report
Added new DC Source for DC Classical SC calculations
Added new DC Source for the calculations and built the estimating method
based on IEC61660.
B. Protection Device Coordination
New Solid State Breaker curve preview
Updated Relay program user interface
Improvements in usability of Digitizer
User adjustable Bus Curve in PDC TCC
Created Multiple Labels in PDC curves
Enhancement of the PDC Show/Restore View icon
-
8/10/2019 What is New in DesignBase 5.0 SP2
4/60
What is New in Paladin DesignBase 5.0 SP2
4
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
Created on/off icon for Opening/Closing the PDC tool-box
On/Off option for Designed Load Amp part of Bus Curve in PDC TCC
New PDC interpolate Function
Transformer Damage Curve Updates according to IEEE C57.12.59 2001
Shows coordinates when moving each PDC curve's arrow in PDC program Added Delete and Append option for elements in PDC study
Added a searching feature for a specific element in multiple PDC studies
Added new G&W relays
Created Crosshair for PDC curves (including value representation on axis)
Enhanced Solid State Breaker curve preview
C. Arc Flash Study
Increase the Arc flash constraint limit on looking for upstream protec tion devices
Enhanced the Arc Flash calculation wizard based on selected bus Arc flash labels always presents System Voltage rather than LF voltage when the
SC Calculated by LF pre-fault voltage
D. Harmonic Analysis
Applied the last slope fac tor to extrapolate resistance R for frequency scanning
Added On/Off option for Harmonics status
Applied scenarios to control On/Off for harmonic sources
E. AC/DC Power Flow
New 3P Inverter and DC Source Models
Enhanced the calculation for DC Current Control and voltage c ontrol for
Rectifiers
F. Ground Grid Program
Added Undo/Redo commands
Added Lock/Unlock features
User Interface improvements
Increased the dec imal numbers in the output report
G. Advanced Power Cable Ampacity
Feature to save units when c hanged from main window
H. Advanced Transient Stability Analysis
-
8/10/2019 What is New in DesignBase 5.0 SP2
5/60
What is New in Paladin DesignBase 5.0 SP2
5
Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute
Increased the limit of Variable shown in the results for general-
models/AVR/Governor/PV models
Enhanced simulation window to show information about events occurring
Showed more decimal numbers for PU values in order to generate smoother
curves
On/Off status of General Models based on device status in different scenarios
Added Signal monitoring tab feature to General Models
I. And Much More
User interface improvements
Error Checker reports improvements
Text Editor spread-sheet view improvements
Added two new features (Adobe Reader and XPS Viewer) in Text Report
program
Added backup/ restore options for project folder/library files
Unzip project without having WINZIP/WINRAR
Created a new DC Source symbol in DC catalogs
Created a new Inverter symbol in 3P Bus catalogs
Added a new shunt capacitor symbol in all the bus catalogs
Added new options in Import/Export Programs
Lists complete descriptions for installed DB license features
Added a port number field to C lient License Manager
The evolution towards Paladin DesignBase 5.0 Service pack 2 represents millions of dollars
and many years of development effort, not only by our on-staff development team, but
by users like you who provide us with valuable guidance on new features and functions.
We thank you for your continued business, and for making Paladin DesignBase the most
effective and productive modeling platform in the mission-critical arena.
-
8/10/2019 What is New in DesignBase 5.0 SP2
6/60
What is New in Paladin DesignBase 5.0 SP2
6
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
Contents
A. Short Circuit Program ................................................................................................................................... 8
1) Bus Selection New Features of 3 Phase Short Circuit Programs .............................................................. 8
2) Save/Import Bus Selection in User Defined Text File ............................................................................ 10
3) Report to CSV file in Detailed Report of IEC363 SC Program ................................................................. 14
4) Add new DC Source for calculations and build the estimation method based on IEC61660. ............... 14
5) New DC Source for Classical Methodology ............................................................................................ 16
B. Protection Device Coordination ................................................................................................................. 17
1) Adjust Bus curve length in PDC TCC ....................................................................................................... 17
2) Show/Hide coordinate symbol .............................................................................................................. 18
3) Add device curve text in PDC program .................................................................................................. 20
4) Enhancement for the PDC "Restore View" icon in PDC toolbar ............................................................ 20
5) Creating on/off icon for Opening/Closing the PDC tool-box ................................................................. 21
6) On/Off for Designed Load Amp part of Bus Curve in PDC TCC .............................................................. 21
7) Transformer Damage Curve Updates according to IEEE C57.12.59-2001 ............................................. 23
8) Show coordinates when moving each PDC curve's arrow in PDC program .......................................... 24
9) Add "delete" option for elements in PDC study to prevent Appending to wrong Study ...................... 24
10) Append new component into existing PDC studies .......................................................................... 25
11) Add options for deleting one or more PDC studies ........................................................................... 26
12) Add a searching feature for equipment name in multiple PDC studies ............................................ 27
13) Creating Crosshair for PDC curves (including value representation on axis) ..................................... 28
14) Digitizer usability improvements. ...................................................................................................... 29
15) Enhanced Solid State Breaker curve preview .................................................................................... 30
C. AC & DC Arc Flash Evaluation..................................................................................................................... 32
1) Increase the Arc flash limitation limit on looking for upstream protection devices ............................. 32
2) Enhancing the Arc flash calculation wizard based on selected bus ....................................................... 33
3) Arc flash labels should always present System Voltage rather than Load Flow voltage when the SC
Calculated by LF pre-fault voltage ................................................................................................................. 33
D. Harmonic Analysis ...................................................................................................................................... 35
1) Added on/off option for harmonic sources ........................................................................................... 35
2) Apply scenarios to control on/off for harmonic sources ....................................................................... 35
E. AC/DC Power Flow ..................................................................................................................................... 36
-
8/10/2019 What is New in DesignBase 5.0 SP2
7/60
What is New in Paladin DesignBase 5.0 SP2
7
Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute
1) Enhanced the Calculation of DC Current Control in Rectifiers .............................................................. 36
2) Sample to simulate AC-DC network for both SC and Load Flow ............................................................ 37
F. Ground Grid Program ................................................................................................................................. 44
1) Undo/Redo functions ............................................................................................................................. 44
2) Lock and Unlock functions ..................................................................................................................... 44
3) Spreadsheet view of grid elements ....................................................................................................... 45
G. Advanced Power Cable Ampacity .............................................................................................................. 46
H. Advanced Transient Stability ..................................................................................................................... 47
1) New features for results of general-models/AVR/Governor/PV models .............................................. 47
2) Relating General Models on/off based on device status in different scenarios .................................... 48
3) New features for simulation windows ................................................................................................... 49
I. Miscellaneous Features ............................................................................................................................. 50
1) Client License Manager .......................................................................................................................... 50
2) Add two new Text Report browser for Adobe Reader and XPS Viewer ................................................ 52
3) Add Backup/Restore options for project folder/library files and both together ................................... 53
4) Unzip project without having WINZIP/WINRAR .................................................................................... 55
5) Create a Upgrade all the PA sample files icon after installing DB5 SP2 ............................................. 55
6) Editor and Text Editor Usability improvements. .................................................................................... 56
7) Error Checker Enhancements: ............................................................................................................... 57
8) Add Case Study list box, Add icon and Delete icon in Short Circuit toolbar .......................................... 58
9) Other Miscellaneous Enhancements: .................................................................................................... 59
-
8/10/2019 What is New in DesignBase 5.0 SP2
8/60
What is New in Paladin DesignBase 5.0 SP2
8
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
A. Short Circuit Program
1) Bus Sele c tion Ne w Fea tures of 3 Pha se Sho rt Circ uit Prog ram s
This feature gives the user an option to select buses either from drawings or from the
buses saved in the short circuit program:
Open the sample file IEC-YY projec t file. (ie: C:\ DesignBase5\ Samples\ 3PhaseSC)
Choose one of AC 3ph SC methods:
- AC ANSI/IEEE
- AC Classical
- AC IEC 60909
- AC IEC 61363
In this example we selected AC Classical:
Select number of buses from the drawings (In this example BUS 1, PPC 3, G1)
Open SC Option dialog box and see which buses were selected (In this example
BUS 1, PPC3, G1) from the drawings in the list, since the default option From
Current Page is selec ted.
-
8/10/2019 What is New in DesignBase 5.0 SP2
9/60
What is New in Paladin DesignBase 5.0 SP2
9
Re str i c ted to Powe r A na lyt i c s Partners | Do No t D ist ribute
Switch to option From Saved to ensure saved buses are showing in the list (In this
example BUS 1, PPC 3, G1).
Switch back to From current Page and the buses selected from the drawings will
be displayed (In this example buses A4P, A7P, A8P, BUS 1, ).
Add buses from All Filtered Buses list (In this example A3CP, A4P, BUS 1, PPC3, G1)
and c lick Save button.
Switch to option From Saved and notice the buses in the list stay the same.
-
8/10/2019 What is New in DesignBase 5.0 SP2
10/60
What is New in Paladin DesignBase 5.0 SP2
10
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
Switch back to From current Page and the buses selected from the drawings
are back on the list (In this example BUS 1, PPC3, G1).
Switch to option From Saved again, click OK to go back to the drawing and you
will see the nodes A3CP, A4P are selected besides BUS 1, PPC3, G1.
2)
Sa ve / Imp ort Bus Sele c tion in User De fine d Tex t File
Open the IEC-YY project file. (ie: C:\ DesignBase5\ Samples\ 3PhaseSC)
Choose one of the AC 3ph SC methods:
- AC ANSI/IEEE
- AC Classical
- AC IEC 60909
- AC IEC 61363
In this example we selected AC Classical:
-
8/10/2019 What is New in DesignBase 5.0 SP2
11/60
What is New in Paladin DesignBase 5.0 SP2
11
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
Select Selected Buses option and select some buses (In this example BUS 1, Bus
2, G1, G2)
Select the Export button and export the list to the text file (SCBusList.txt)
This file will keep the selected bus list which you may import anytime to do SC
study.
-
8/10/2019 What is New in DesignBase 5.0 SP2
12/60
What is New in Paladin DesignBase 5.0 SP2
12
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
Continue with SC study and generate the results (V4Results.txt)
Close the software
Launch DesignBase
Run the SC program (AC Classical)
Use the selec ted Buses and the Import option to open from the selec ted bus list
(SCBUSLIST.txt)
-
8/10/2019 What is New in DesignBase 5.0 SP2
13/60
What is New in Paladin DesignBase 5.0 SP2
13
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
-
8/10/2019 What is New in DesignBase 5.0 SP2
14/60
What is New in Paladin DesignBase 5.0 SP2
14
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
3) Rep o rt to CSV file in Deta iled Rep ort o f IEC363 SC Prog ram
Now users can export the Detailed Report as a CSV file in SC IEC363:
4) Ad d ne w DC Source for ca lcu la t ions and bui ld the est im at ion me thod b ased on
IEC61660.
This new feature includes a new model for DC sources according to IEC61660:
-
8/10/2019 What is New in DesignBase 5.0 SP2
15/60
What is New in Paladin DesignBase 5.0 SP2
15
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
The Short Circuit page should be set by considering the following items:
SC Rating could be either Rated Amps or rated kW.
DC Smoothing Reactor Data is the same as Rectifier in IEC61660 standard
AC Impedance data is the equivalent impedance converted to AC low voltage
side. The values can be entered manually or calculated from Maximum SC current
at the terminal bus to match IEC 61660 standards as follows
=6 1000
(. 13660 1)
Iscmaxcan be entered directly or calculated from Rated Amps and SC factor Ksc.
Estimate Rac button is used to estimate AC Impedance with Rac/Xac fixed
Running the DC IEC61660 SC program will result to the following report:
- - - - - - - - - - - - - - - - - - - - - - -Recti f i er( s) Dat a
- - - - - - - - - - - - - - - - - - - - - - -AC Ci r cui t Si de DC Ci r cui t
Syst em Act ual Rat ed - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Bus Name V V Cd A Z- mOhm R- mOhm L- mH R- mOhm L- mH- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -DCS 250 250 DS 2000 4. 0760 2.3541 0. 0106 98. 68 0. 0300
Which means : Rac = 2.354 mOhms
The Analyze button will generate Output Branch Results Reports:
-
8/10/2019 What is New in DesignBase 5.0 SP2
16/60
What is New in Paladin DesignBase 5.0 SP2
16
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
- - - - - - - - - - - - - - -Bus Resul t s
- - - - - - - - - - - - - - -
Sust ai n Peak Peak Ri si ng Decl i neTheveni n I k I p Tp T1 T2 Rat e of Ri se
Bus Name Cd R( Ohm) L ( mH) A A mSec mSec mSec A/ mSec
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -DCS DS 0. 0833 0. 3389 3000 3000 12. 20 4. 07 100. 00 738F1 0. 0833 0. 3389 3000 3000 12. 20 4. 07 100. 00 738
The contribution of dc Source DCS Ik= 3000 A ,which will match the value in the editor as
expected.
5) New DC Source for Classica l Me thodo logy
A new DC source which has discussed before is also verified to cover DC Classical ShortCircuit method.
The editor of this new DC source model includes the same data as the rectifier.
-
8/10/2019 What is New in DesignBase 5.0 SP2
17/60
What is New in Paladin DesignBase 5.0 SP2
17
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
B. Protection Device Coordination
1) Ad just Bus curve leng th in PDC TCC
The length of a Bus curve can be adjusted by dragging the handle at the bottom of the
Bus curve.
-
8/10/2019 What is New in DesignBase 5.0 SP2
18/60
What is New in Paladin DesignBase 5.0 SP2
18
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
2) Show / Hide c oo rd inate sym bo l
The coordinate symbols can be shown by right-clicking "Show/Hide Coordinate" menu
item on the TCC window and then selec ting Yes in the following dialog box.
The coordinate symbol can be hidden again by right-clicking "Show/Hide Coordinate"
menu item on the TCC window and then confirming in the appeared dialog box.
The coordinate
symbol will be
shown
Right Click
-
8/10/2019 What is New in DesignBase 5.0 SP2
19/60
What is New in Paladin DesignBase 5.0 SP2
19
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
Create multiple coordinate symbols in PDC curves
The new multiple coordinate symbols can be created by right-clicking the Insert
Coordinate menu item on TCC window and then selecting Yes in the following dialog
box.
Multiple
coordinate
symbols
Right Click
-
8/10/2019 What is New in DesignBase 5.0 SP2
20/60
What is New in Paladin DesignBase 5.0 SP2
20
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
3) Ad d dev ice c urve tex t in PDC program
The multiple annotation symbols can be dragged from the Annotation catalog into TCC
view.
4) Enha nc em ent for the PDC "Restore View" ic on in PDC too lba r
In the PDC toolbar, the Restore View icon is only shown when showing the PDC study
and the Show Study icon is only shown when not showing the PDC study. The zoom of
the main drawing is kept as the same as before anything was changed after clicking
Show Study icon and then clicking Restore View icon.
-
8/10/2019 What is New in DesignBase 5.0 SP2
21/60
What is New in Paladin DesignBase 5.0 SP2
21
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
5) Creat ing on/ of f icon for Ope ning/ Closing the PDC tool-box
After clicking the Show/Hide Symbol Catalogs icon, the catalog window will appear.
After clicking the Show/Hide Symbol Catalogs icon again, the catalog window will
disappear.
6) On/ Off for Designe d Loa d Am p p a rt of Bus Curve in PDC TCC
When unchecking the Hide Design Load Amps check box in the following Bus Curve
dialog box, the Bus design load amps will be shown in TCC view below. This option is
designed to show or hide the Bus design load amps in TCC view.
Show/Hide
Symbols
Catalogs
-
8/10/2019 What is New in DesignBase 5.0 SP2
22/60
-
8/10/2019 What is New in DesignBase 5.0 SP2
23/60
What is New in Paladin DesignBase 5.0 SP2
23
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
7) Transform e r Dam ag e Curve Upd a tes a c c o rding to IEEE C57.12.59-2001
When the cooling type is a Dry-Type and the transformer belongs to categories I or II, IEEE
CS7.12.59-2001 standard c an be selec ted in the following dialog box.
-
8/10/2019 What is New in DesignBase 5.0 SP2
24/60
What is New in Paladin DesignBase 5.0 SP2
24
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
8) Show c oo rd inates when m oving e ac h PDC c urve 's arrow in PDC program
When holding down each PDC curves arrow and moving it, the coordinate values will
be shown in the Toolbar.
9) Ad d "dele te" opt ion for e lem ents in PDC study to p reve nt App end ing to wrong Study
In a PDC single line page, after selec ting the elements in a PDC study then pressing
Delete button, the following dialog box will be shown to ask whether or not to delete the
study.
Hold downPDC
Curves arrow
and move it
Watch
coordinate
values
-
8/10/2019 What is New in DesignBase 5.0 SP2
25/60
What is New in Paladin DesignBase 5.0 SP2
25
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
10 )Ap pe nd new c om po nent in to ex ist ing PDC stud ies
Add new elements into existing PDC by appending them into a corresponding PDC
study:
Existing PDC Study
Select new elements and then
Append to the existing PDC study
-
8/10/2019 What is New in DesignBase 5.0 SP2
26/60
-
8/10/2019 What is New in DesignBase 5.0 SP2
27/60
What is New in Paladin DesignBase 5.0 SP2
27
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
12 )Ad d a sea rc h ing fea ture for eq uipm ent nam e in m ul tip le PDC stud ies
After clicking Edit/Search Equipment in PDC Studies menu item in PDC toolbar, the
following dialog box will be shown. All the selec ted equipment on the left side is
included in the selec ted PDC study on the right side.
When searching for one or more equipment name in multiple PDC studies in the above
-
8/10/2019 What is New in DesignBase 5.0 SP2
28/60
What is New in Paladin DesignBase 5.0 SP2
28
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
dialog box, the equipment found in each PDC study will be shown below:
13 )Crea ting Crossha ir for PDC c urves (includ ing va lue rep resentat ion o n a xis)
By holding down the arrow handle of the c oordinate symbol and moving it, the following
crosshair will automatically be shown. By releasing the arrow handle of the coordinatesymbol, the crosshair will automatically disappear.
-
8/10/2019 What is New in DesignBase 5.0 SP2
29/60
What is New in Paladin DesignBase 5.0 SP2
29
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
The coordinate values will be shown in Toolbar and TCC view below.
14 )Dig it izer usab i li ty imp rovem ents.
The Digitizer program has been enhanced to return to the build program by pressing the
new Return to Build Program button in the Digitizer. The Digitizer minimizes and returns you
to the build program. From there the user can continue editing the same curve or edit a
different curve.
-
8/10/2019 What is New in DesignBase 5.0 SP2
30/60
What is New in Paladin DesignBase 5.0 SP2
30
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
15 )Enha nc ed Solid State Break er c urve preview
A new curve preview has been created for enhancing the usability of Solid State Breakers
which now includes Long and Short Time Pickup and Instantaneous Pickup all in the same
diagram:
-
8/10/2019 What is New in DesignBase 5.0 SP2
31/60
What is New in Paladin DesignBase 5.0 SP2
31
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
Other features included in PDC Program are:
- Updated G&W relays
- Shows bus name in PDC single line
- Does not show PDC drawings in the page drop down menu
- Sort PDC study name in the PDC toolbar
- Addition of two new features to change pen thickness and order of the user defined
SC arrows
- Automatic addition of buses to PDC Studies when a branch is selected
- Enhanced Relay Program user interface
-
8/10/2019 What is New in DesignBase 5.0 SP2
32/60
What is New in Paladin DesignBase 5.0 SP2
32
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
C. AC & DC Arc Flash Evaluation
1) Increa se the Arc flash l im ita t ion l imit on loo king for upstrea m protec t ion d evic es
The maximum fault contribution levels will be available for users to set. Its default value is 10
and can be increased up to 20 branches in upstream circuit. The user can set this value
based on his protection strategy and size of the network and the calculation speed on the
computer. This will update short circuit and PDC studies for contribution levels
automatically. This setting means every bus/equipment should be protected by a device in
at most 20 levels up branches.
-
8/10/2019 What is New in DesignBase 5.0 SP2
33/60
What is New in Paladin DesignBase 5.0 SP2
33
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
2) Enhanc ing the Arc f lash ca lcu la t ion w izard b ased o n selec ted b us
This feature will automatically recalculate and show the results of the selected bus. The
user can change the selected bus in Show Bus and arc flash engine will automatically
calculate and show the results in this window.
3) Arc fla sh lab els should a lwa ys p resent System Voltag e rathe r tha n Loa d Flow v oltag e
whe n the SC C alc u la ted by LF pre-fau l t vo l tag e
When the Short Circuit Calculation uses Power Flow Voltage as pre-fault voltage, then
all calculations will be based on Load flow voltage as a pre-fault and the Arc-Flash
Engine would also use this voltage which might be different from system voltage. To keep
the system data consistent, Arc-Flash labels should present System Voltage rather than
what the user considered in SC calculations. Labels are a lways present in System Voltage
but Arc-Flash report still will show LF voltage as a pre-fault voltage.
-
8/10/2019 What is New in DesignBase 5.0 SP2
34/60
What is New in Paladin DesignBase 5.0 SP2
34
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
-
8/10/2019 What is New in DesignBase 5.0 SP2
35/60
What is New in Paladin DesignBase 5.0 SP2
35
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
D. Harmonic Analysis
1) Ad de d on/ of f op t ion for harm onic source s
This feature creates new option for the user to be able turn on/off harmonic sources in a
study.
2) Ap ply scena rios to c ontro l on/ of f for harmo nic source s
In addition we applied this option to c ontrol harmonic sources on/off feature by
Scenarios.
-
8/10/2019 What is New in DesignBase 5.0 SP2
36/60
What is New in Paladin DesignBase 5.0 SP2
36
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
E. AC/DC Power Flow
1) Enha nc ed the C a lculat ion o f DC C urrent C ontrol in Rec tif iers
The DC load flow now includes the DC current control order with Zero Amp for the RatedCurrent.
In addition, a Warnings message will be generated if Rec tifier DC Voltage Control Order
Is set to Zero after running DC Load Flow Report Manager\ Log File:
Bus Source < REC1>:
System Voltage is applied for DC Control Voltage Order due to it
-
8/10/2019 What is New in DesignBase 5.0 SP2
37/60
What is New in Paladin DesignBase 5.0 SP2
37
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
2) Sam p le to simula te AC -DC netw ork for bo th SC a nd Loa d Flow
Service Pack 2 also includes new symbols and settings to ease the modelling of
integrated AC -DC networks. This sec tion will present how to model this kind of network
with a simple example as shown below for a typical AC/DC configuration.
The sample file can be accessed from: C:\ DesignBase5\ Sam pe ls\ ACDCLF\ AC_DC_Conver ter .ep r
Modelling in DesignBase:
-
8/10/2019 What is New in DesignBase 5.0 SP2
38/60
What is New in Paladin DesignBase 5.0 SP2
38
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
- DC-AC Devic e ( Inverter)
As shown in the drawing OCC-4WI is an inverter with two components connec ted to the
DC and AC networks separately. The inverters DC Component which is connec ted to
the DC side should be dragged and dropped from the DC catalog.
This component can be controlled as DC Current Control or DC Voltage Control
which can be set in its Load Flow tab page. It works as a bus for Short Circuit studies.
The AC C omponent works as a Source on the AC Side and it should be dragged from
AC catalog by looking for Inverter symbol.The AC component should have the samename as the DC component:
-
8/10/2019 What is New in DesignBase 5.0 SP2
39/60
What is New in Paladin DesignBase 5.0 SP2
39
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
For Short Circuit studies this should be set as a Current Limitation Source which can be
calculated from Rated Parameters. For load flow the PG should be set to zero and PL
should be non-zero in order to pass the DC control from DC component. (PG=0, PL0)
- AC -DC Bi-Direc t iona l Co nve rter
As shown in the main drawing OCC-GTI is a bidirec tional converter:
The bi-directional model includes two different modes: a rectifier mode and an inverter
mode. Each mode is modeled by different components for AC and DC sides separately
and should be ac tivated individually by defining the two different scenarios.
The inverter mode includes the same components which are described above by using
the same name for both components. (in this example the AC Source and it is
deac tivated in the current scenario were used)
In the rectifier mode the DC side is modeled with a DC Source (rec tifier) and the AC side
is modeled with an AC load which can be dragged from AC catalog by looking for
Rectifier Symbol. Both components should have the same name. ( This example used DC
Source).
The AC component is a Bus for Short Circuit Studies. For load flow study its kvar should be
-
8/10/2019 What is New in DesignBase 5.0 SP2
40/60
What is New in Paladin DesignBase 5.0 SP2
40
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
set at Zero in order to accept the current control results from DC side.
The DC component is also set as a DC Source on the DC Side and can be dragged from
the DC catalog by looking for the DC source.
For Short Circuit Studies, its SC Current can be limited and is estimated by AC impedancefrom the Rated Parameters per IEC61660 standard. For load flow standards the DC
Control should be set either to Current Control or Voltage Control and by using the
same name as the AC side Rectifier Load it can pass the control parameters to the AC
side.
-
8/10/2019 What is New in DesignBase 5.0 SP2
41/60
What is New in Paladin DesignBase 5.0 SP2
41
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
- DC-DC C onve rter
As shown in the drawing OCC-DCDC is a DC converter with two components connected
with LV=120 V and HV=240V sides.
A DC-DC converter can be dragged from the DC catalog. There is no meaningful data
for the branch since the two voltage networks are isolated from eac h other in the real
world.
-
8/10/2019 What is New in DesignBase 5.0 SP2
42/60
What is New in Paladin DesignBase 5.0 SP2
42
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
The HV Source can be dragged just by selecting a DC Source from the DC c atalog. Its
Short Circuit Current can be limited by using an estimation of AC impedance from the
Rated Parameters per IEC61660 standard. For the load flow it should be set to DC
Current Control with zero Amps in order to pass the control from LV to HV
Selec t Current C ontrol and set Order =0 to transfer the power from LV side.
-
8/10/2019 What is New in DesignBase 5.0 SP2
43/60
What is New in Paladin DesignBase 5.0 SP2
43
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
- Sc ena rios need to be de f ined :
Scenarios can be used to switch the status of the bidirectional converter.
Rec tif ier Mod e
AC Source is switched off and DC Source is activated to pass the power from AC to DC.
Inverter Mod e
DC Source is switched off and AC Source is activated to pass the power from DC to AC .
-
8/10/2019 What is New in DesignBase 5.0 SP2
44/60
-
8/10/2019 What is New in DesignBase 5.0 SP2
45/60
What is New in Paladin DesignBase 5.0 SP2
45
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
3) Sp read shee t view o f grid elem ents
New buttons for adding new elements and a lso a selection option either from spreadsheet
selection or from diagram have also been added.
-
8/10/2019 What is New in DesignBase 5.0 SP2
46/60
What is New in Paladin DesignBase 5.0 SP2
46
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
G. Advanced Power Cable Ampacity
Cable Ampacity Program is enhanced to show diagram units now and it can be changed
through the main windows rather than the project setting dialog.
-
8/10/2019 What is New in DesignBase 5.0 SP2
47/60
What is New in Paladin DesignBase 5.0 SP2
47
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
H. Advanced Transient Stability
1) New fea tures for results of gen eral-m od els/ AVR/ Go ve rnor/ PV mo d els
In the new version of the advanced transient software, the limit of the variable shown in
the results for general-models/AVR/Governor/PV models has been increased by up to
44 signals.
User can select View Graphical Results and under the UDM tab (new feature to show user
defined model variables) he/she will be able to select desired number of signals to be
plotted.
-
8/10/2019 What is New in DesignBase 5.0 SP2
48/60
What is New in Paladin DesignBase 5.0 SP2
48
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
2) Rela t ing G ene ra l Mo de ls on/ off ba sed on d ev ice status in different sc ena rios
To prevent the software from creating an error message when its associated bus/branch isout of service in the single line (in current scenario), an automatic updatable on/off status
has been added:
-
8/10/2019 What is New in DesignBase 5.0 SP2
49/60
What is New in Paladin DesignBase 5.0 SP2
49
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
3) New features for simu lat ion wind ow s
In order to enhance the transient simulation windows, an Event Log window has been
added to the main windows to show a list of events that happen during simulation based
on View Text Results. In addition, the main windows curves have been generated by
more decimal values to show a smoother curve for voltage PU and frequency values:
-
8/10/2019 What is New in DesignBase 5.0 SP2
50/60
What is New in Paladin DesignBase 5.0 SP2
50
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
I. Miscellaneous Features
1) Cl ient Lice nse Ma nag er
The serial number will be shown in the Client License Manager page if there is a serial
number in the license file. The new four CORE, SUPER, POWER and PE license packages will
be shown if one of those license packages exists in the license file.
The port number can be changed and can be changed bac k after clicking the Defaultbutton in the following dialog box. The default port number is 27002 when using the license
server.
-
8/10/2019 What is New in DesignBase 5.0 SP2
51/60
What is New in Paladin DesignBase 5.0 SP2
51
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
By clicking the Show License Information button in the client license manager dialog box,
the complete descriptions for the installed DB license features and package name will be
shown as follows:
-
8/10/2019 What is New in DesignBase 5.0 SP2
52/60
What is New in Paladin DesignBase 5.0 SP2
52
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
2) Ad d tw o ne w Text Rep ort browser for Ad ob e Rea d er and XPS View er
Launch the Text Report program by selec ting Tools/Global Edits/Change the settings for
the Text Report as follows:
Two new formats including Adobe Reader and XPS Viewer have been added. The current
settings such as font size, font color, watermark, and so on for Adobe Reader and XPS
Viewer can be c hanged when clicking the Change C urrent Settings button.
For example, when changing the font color to blue and watermark to DRAFT, saving the
settings and then selecting Adobe Reader as a browser, the PF report will be created as
follows:
-
8/10/2019 What is New in DesignBase 5.0 SP2
53/60
What is New in Paladin DesignBase 5.0 SP2
53
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
In the same way, when changing the font color to red and watermark to SAMPLE, saving
the settings and then selec ting XPS Viewer as a browser, the PF report will be created as
follows:
3) Ad d Bac kup / Restore op t ions for pro jec t fo lder/ l ib rary f iles and bo th together
When selecting File/ Backup Library Files in DB5 SP2, the following dialog box will beshown. All the selected library files can be zipped to a backup file. The default path to the
backup files is C:\ DesignBase5\ Bac kUp. All the selected options from the Data folder and
can also be browsed from different locations.
-
8/10/2019 What is New in DesignBase 5.0 SP2
54/60
What is New in Paladin DesignBase 5.0 SP2
54
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
When selec ting File/ Restore Library Files in DB5 SP2, the following dialog box will appear.
All the files in the selected zip file will be unzipped to the selected folder when clicking
Restore button in the following dialog box.
-
8/10/2019 What is New in DesignBase 5.0 SP2
55/60
What is New in Paladin DesignBase 5.0 SP2
55
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
4) Unzip p rojec t w ithout ha ving WINZIP/ WINRAR
By Selecting File/Unzip Project the user can select any packed folder including the
projec t files into the current folder. Following dialog box will be shown which show the path
of packed folder.
5) Cre a te a Up g rad e a ll the PA sam p le files ic on a fter insta lling DB5 SP2
After installing DB5 SP2, a Upgrade all the PA sample files icon is created. By clicking this
icon, all the sample files under c:\ designbase5\ samples folder will be upgraded:
-
8/10/2019 What is New in DesignBase 5.0 SP2
56/60
What is New in Paladin DesignBase 5.0 SP2
56
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
6) Ed itor and Tex t Ed itor Usa b ility im p rovem en ts.
All Text Editor equipment filters can be edited.
The user can select and copy/paste in the Text Editor Spreadsheet:
-
8/10/2019 What is New in DesignBase 5.0 SP2
57/60
What is New in Paladin DesignBase 5.0 SP2
57
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
Periodic field entry as spreadsheet for AC Voltage Profile:
7) Error C hec ke r Enha nc em ents:
Error Checker reports Harmonic devices which are not connec ted to network and
harmonic devices which are connected to an unpowered island.
-
8/10/2019 What is New in DesignBase 5.0 SP2
58/60
What is New in Paladin DesignBase 5.0 SP2
58
Re str i c ted to Powe r A na lyt i c s Pa rtne rs | Do No t D ist ribute
Error Checker can now correc t certain errors automatically. The user can Right-Click on the
highlighted entries to open the menu, and c hoose to correc t the single error or all similar
errors.
8) Ad d C a se Study l ist box , Ad d ic on a nd Delete ic on in Short Circuit too lba r
If the Case Study for the Options with @ in the SC option dialog box checked, the C ase
Study list box, Add icon, and Delete icon will be created in the Short Circuit toolbar as
follows:
-
8/10/2019 What is New in DesignBase 5.0 SP2
59/60
What is New in Paladin DesignBase 5.0 SP2
59
Re str i c ted to Powe r A na lyt i c s Pa rtners | Do No t D ist ribute
The case study name is listed in Case Study list box. Different case study names can be
selected. When clicking Add icon (or +), a case study can be added. When clicking
Delete icon (or X), a case study can be deleted.
By unchecking Case Study for the Options with @ in the SC option dialog box, the Case
Study list box, Add icon, and Delete icon will disappear in Short Circuit toolbar as follows:
9) Othe r Misc el lane ous Enha nc em ents:
- User interface improvements
- Created a new DC Source symbol in DC catalogs
- Created a new Inverter symbol in 3P Bus catalogs
- Added a new shunt capacitor symbol in all the bus catalogs
- Added new options in Import/Export Programs
-
8/10/2019 What is New in DesignBase 5.0 SP2
60/60