Transcript
Page 1: Vanguard Tibial Bearings · The UHMWPE Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement. Elsevier Academic Press. San Diego, CA. 2004. 7. Parks, N. et

Cruciate Retaining

• 3°posteriorslope• 15°internal/externalrotation

Cruciate Retaining Lipped

• Enhancedposteriorlip• 15°internal/externalrotation

Vanguard® CompleteKneeSystem CruciateRetaining

Knees • Hips • Extremit ies • Cement and Accessories • PMI® • Technology

References 1.Beading,L.DirectMoldedComponentsShowntoResistOxidation.

Orthopedics Today.17(4):1997.

2.Furman,B.et al.(Abstract)EffectofResinTypeandManufacturingMethod on UHMWPE Oxidation and Quality at Long Aging andImplantTimes.43rdAnnualMeetingOrthopaedicResearchSociety,SanFrancisco,CA,February9–13,1997.

3.Beading, L. Polyethylene-Related Failure: A Challenge to TKA.Orthopedics Today.16–21,1996.

4.Ritter, M. et al. Long-Term Survival Analysis of a PosteriorCruciate-Retaining TotalCondylar Total KneeArthroplasty.Clinical Orthopaedics and Related Research.309:136–145,1994.

5.DataonfileatBiomet.Benchtestresultsnotnecessarilyindicativeofclinicalperformance.

6.Kurtz, S. et al. The UHMWPE Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement. ElsevierAcademicPress.SanDiego,CA.2004.

7.Parks, N. et al. Modular Tibial Insert Micromotion. Clinical Orthopaedics and Related Research.356:10–15,1998.

8.Sosa, M. et al. Micromotion Between the Tibial Tray and thePolyethylene Insert. Fifth World Biomaterial Congress. TorontoCanada,May29–June2,1996.

9. Incavo,S.et al.TibialPlateauCoverageinTotalKneeArthroplasty.Clinical Orthopaedics and Related Research.299:81–85,1994.

All trademarks herein are the property of Biomet, Inc. or its subsidiaries unlessotherwiseindicated.

ThismaterialisintendedforthesoleuseandbenefitoftheBiometsalesforceandphysicians.Itisnottoberedistributed,duplicatedordisclosedwithouttheexpresswrittenconsentofBiomet.

Forproductinformation,includingindications,contraindications,warnings,precautionsandpotentialadverseeffects,seethepackageinsertandBiomet’swebsite.

P.O.Box587,Warsaw,IN46581-0587•800.348.9500x1501©2007,2010BiometOrthopedics•biomet.com

FormNo.BOI0264.1•REV083110

Vanguard®TibialBearingsVanguard®TibialBearingsareavailableinArCom®DirectCompressionMolded(DCM)polyethyleneandE1™AntioxidantInfusedTechnology.ArCom®polyethyleneisclinicallyproventoberesistanttowear,delaminationandoxidation.1–4

E1™AntioxidantInfusedBearings,foundedonArCom®heritage,areinfusedwithvitaminE,anaturalantioxidant.E1™technologydefinesanewclassoftibialbearingsandovercomesthelimitationsofremeltedandannealedpolyethylenesbyunitingtrueoxidativestability,highmechanicalstrengthandultralowwear.5,6

Anterior Stabilized

• Prominent10mmanteriorlip• 5mmposteriorlip• 6°internal/externalrotation

DCMUHMWPE

Volu

met

ric

Wea

r R

ate

(mm

3 /M

C)

Volumetric Wear Rates of Largest Cruciate Retaining (CR)

Tibial Bearing Profile1

Tested at Biomet Biomaterials Laboratory

86% CR wear reduction

over Direct Compression

Molded

E1™ Material

0

10

20

30

40

50

43.4

6.1

Page 2: Vanguard Tibial Bearings · The UHMWPE Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement. Elsevier Academic Press. San Diego, CA. 2004. 7. Parks, N. et

0–15°

The Vanguard® Complete Knee System

providesforpersonalizedpatientcareby

allowing a custom-fit of the femoral, tibial

and patellar components independently,

thus addressing the largest possible

percentageofthepopulation.

Vanguard® CompleteKneeSystemCruciateRetaining

Softened Anterior Flange

Streamlineddesigntohelpavoidincidenceof“retinaculartenting”

Deep Trochlear Groove

Reducespatellarforcesthroughoutrangeofmotion

Proportional Posterior Condyles

Allowsforoptimalcontactareaindeepflexion

Wide Proximal Trochlear Groove

Providesexcellentpatellartrackingregardlessofpatient’sQ-angle*

Optimized Tibiofemoral Articulation

Increasedcontactareainhighflexionandaxialrotation

Extended Trochlear Groove

Allowsthepatellatomaintainfullcontactwiththefemoralcomponentindeepflexion

AdditionalFeaturesofthe Vanguard®CRDesign:• 10femoralcomponentsthatgrowanterior/posterioronaverage

by2.4mmincrements

• Fullyinterchangeabletibial/femoralsizing

• 1:1tibial/femoralcoronalcongruency

• PPS®PorousPlasmaSprayCoatingforcementlessorInterlok®finishforcementedapplications

Interchangeable Bearing Options

CR,CRLippedandASbearingscanbeutilizedwiththeCRfemur

Rotated Bearing Surface Articulation

Increasescontactareaby13percent1

Proven Compressive Locking Mechanism

Clinicallyproventominimizemicromotionandbacksidewear5

Tibial Tray Design

Symmetrictibialtrayavailableinninesizesforoptimaltibialcoverage6

Biomet®TibialTrayTheVanguard®CompleteKneeSystemfeaturesasymmetricaltibialtraydesignforoptimalcoverage,ArCom®andE1™TibialBearingsforprovenwearresistance1–4andaprovenlockingmechanismshowntobe“themoststableoverall.”7,8Biomet®tibialtraysareavailablewithInterlok®finishforcementedapplicationsorRegenerex®PorousTitaniumConstructtoenhancebonefixationincementlessapplications.

Raised Anterior Lip

Providesenhancedfemoralrotationalstabilityandcontrolsanteriorfemoralslide

Patellar Tendon Relief

Facilitatesincreasedrangeofmotion

*within0–15°ofQ-angle

Removable Lugs

Formodularaugmentation

Independent Augments

CRcomponentcanacceptposteriorordistalfemoralaugments