Transcript
Page 1: Unit no. SU-14 STEAM UNIT - Home - IKM

Unit no. SU­14

STEAM UNIT

DimensionsLength(mm)..................................................................: 3647 Width(mm).............................................: 2434 Height(mm).............................................: 2922Weight (kg)..................................................................: 8400Lifting/ Transportation..........................................: 12' Offshore container with forklift channels and lifting slings. DNV 2.7­1Certificate(s) / Serial No:......................................: FMW9039/11/97

Construction yearBuilt..................................................................: 1998

Area of use /  certificationOnshore/offshore..................................................................: OffshoreStandard.........................................................: Norsok Z­015 ­ Unclassified area (80 dBa)

Flow / Pressure / VolumeBoiler...........................................................: Clayton E­185 (Ser. No: BG 47044­B 6243)Spark Arrestor...................................................: DNV certified. (Ref. cert./Ser. no. : SU­14b / GF­02)

Dimension : L 2820mm W 1000mm H 1570mm. Weight : 560 kgLifting/Transport : 2­leg chain sling

Maximum Effect (kW)..................................................................: 1850Max. steam production (kg/hr)..................................................................: 2900P­max (bar)..................................................................: 10 P­max (PSI).............................................: 145Max Steam temperature (Gr.C)..................................................................: 184Feed water tank volume (ltr)..................................................................: 1240Diesel Tank Volume (ltr)..................................................................: 715Diesel consumption (ltr/hr)..................................................................: 210

ConnectionsInlet connection.................................................: 1" offshore claw couplingOutlet connection................................................: 2” Steamcoupling Boss Spud (New type)

FilterInlet filter house (type)........................................: Feedwater inlet: HECO 899014001 

Diesel inlet: RACOR 500 FGInlet filter element (type)......................................: Feedwater inlet:  PX 2010

Diesel inlet: PF­598­30

Power supplyFuse (qty)..................................................................: 1 Fuse (A).............................................: 63El.Power1..................................................................: 400­480 V (main) (Hz).............................................: 50/60 (kW).............................................: (A).............................................: 63El.Power2..................................................................: 690 V (main) (Hz).............................................: 50/60 (kW).............................................:El.Power3..................................................................: 230 V 

(Fire,gas,light,heat)(Hz).............................................: 50/60 (kW).............................................:

Additional information

Page:1 of 2

Page 2: Unit no. SU-14 STEAM UNIT - Home - IKM

Unit no. SU­14

Equipment / Functions............................................: High fire steam production : 2900 kg/hour @ 7,5 barLow fire steam production : 1450 kg/hour @ 10 bar

­ The water consumption at full effect is 20% higher than the steam production. 

Sprinkler system : Swordsman foam system.Fire, gas central : Ceag Eexde IIC T5 Ser. no. J0115/D/S

Ignition source connection and pressure relief steam if:­10% gas alarm (Detector mounted near air inlet).­ Flame detector, fault and emergency shut­down.­ Emergency shut­down on the outside of the container and the interior of the container.­ Shut down/Emergency shut­down from control room. NAS/ESD

Other safety functions : ­ Flame detector on burner.­ Ring thermostat on coil.­ Level monitor in feed water tank.­ Temperature monitor steam 225˚C­ Max. surface temperature is 200ºC.­ Max. exhaust temperature is 300ºC.­ Fire, gas, fault

Signal SCR:­ Shut­down NAS/ESD

Page:2 of 2