Componentes dos Sistemas de Refrigeração
![Page 4: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/4.jpg)
Compressores
Principais tipos de Compressores:
Compressor alternativo
Compressor centrífugo
Compressor de parafusos
Compressor de palhetas
Compressor Scroll
![Page 5: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/5.jpg)
Compressor Alternativo
![Page 6: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/6.jpg)
Compressor Alternativo
Tipos de Compressores Alternativos:
De simples ou duplo efeito;
De um ou mais cilindros;
Abertos, herméticos ou semi-herméticos;
Horizontais, verticais, em V, em W ou radiais.
Sua capacidade de refrigeração varia desde pequenas frações até centenas de kW (1 a 700kW)(pequenas frações até 200 TR)
Obs.: TRTonelada de Refrigeração (1TR = 3,5 kW)
![Page 7: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/7.jpg)
Compressor Alternativo Aberto
![Page 8: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/8.jpg)
Compressor Alternativo Aberto
Unidade Condensadora
![Page 9: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/9.jpg)
Compressor Alternativo Semi-Hermético
![Page 10: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/10.jpg)
Compressor Alternativo Semi-Hermético
![Page 11: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/11.jpg)
Compressor Alternativo Hermético
![Page 12: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/12.jpg)
Compressor Alternativo Hermético
![Page 13: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/13.jpg)
Compressores Abertos
• Exigem um selo na ponta do eixo,
• Variação de sua rotação apenas pela modificação das polias
• Manutenção mais fácil (motor e compressor separados)
Compressores Herméticos e Semi-herméticos
• Funcionamento mais silencioso
• Difícil o surgimento de vazamentos de refrigerante
• O óleo age como refrigerante, isolante e lubrificante do motor
• Juntas podem dar origem a vazamentos de fluído frigorífico (semi)
• Não podem ser utilizados com amônia
• Maior taxa de rejeição de calor no condensador
![Page 14: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/14.jpg)
Compressor Alternativo
Diagrama Pressão-Volume
31
m
![Page 15: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/15.jpg)
Compressor Alternativo
Eficiência volumétrica de espaço morto
3 1v,m
3 m
V V100
V V
Definindo fração de espaço morto rm , como:
mm
3 m
Vr 100V V
Resulta para a Eficiência volumétrica de espaço morto
1v,m m
m
V100 r 1V
![Page 16: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/16.jpg)
Compressor Alternativo
Para expansão politrópica então:1/ k
d1
m 1
pVV p
1v,m m
m
V100 r 1V
1/ kd
v,m m1
p100 r 1
p
![Page 17: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/17.jpg)
Compressor Alternativo
1/ kd
v,m m1
p100 r 1
p
![Page 18: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/18.jpg)
Eficiência volumétrica de espaço morto X
Temperatura de evaporação
Refrigerante R22Tc=35 oC
Compressor Alternativo
![Page 19: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/19.jpg)
Compressor Alternativo
Potência
iP m h
Onde : variação de entalpia na compressão isentrópica
e
ihv,m
aspm taxa de deslocamento
100 v
![Page 20: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/20.jpg)
Compressor Alternativo
Trabalho de compressão e potênciaX
Temperatura de evaporação
Refrigerante R22Tc=35 oC
![Page 21: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/21.jpg)
Compressor Alternativo
Capacidade de refrigeração X
Temperatura de evaporação
Refrigerante R22Tc=35 oC
1 4q m(h h )
![Page 22: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/22.jpg)
Compressor Alternativo
Coeficiente de eficácia - COPX
Temperatura de evaporação
Refrigerante R22Tc=35 oC
![Page 23: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/23.jpg)
Eficiência volumétrica de espaço morto X
Temperatura de Condensação
Refrigerante R22To= 20 oC
Compressor Alternativo
![Page 24: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/24.jpg)
Capacidade de Refrigeração X
Temperatura de Condensação
Refrigerante R22To= 20 oC
Compressor Alternativo
![Page 25: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/25.jpg)
Potência X
Temperatura de Condensação
Refrigerante R22To= 20 oC
Compressor Alternativo
![Page 26: UFBA UNIVERSIDADE FEDERAL DA BAHIA ESCOLA POLITÉCNICA](https://reader033.vdocuments.mx/reader033/viewer/2022051317/56816867550346895ddece19/html5/thumbnails/26.jpg)
Cap. Frigorífica[ kcal/h]
Tc, oC
To,oC30 40 50
-20,0 14.410 12.650 10.810 -15,0 18.030 15.950 13.840 -10,0 22.050 19.610 17.070 -5,0 27.050 24.350 21.450 0,0 33.000 29.750 26.200 +5,0 39.800 35.900 32.000+10,0 47.450 43.000 38.300
Compressor Alternativo