Transcript
Page 1: THERMOSTATS EMERSON BLUE 6 THERMOSTATSs3.supplyhouse.com/product_files/White Rodgers - 1F95-0680 - Brochure.pdfEMERSON BLUE 6” THERMOSTATS BLUE 6” - UNIVERSAL AND SINGLE STAGE

EMERSON BLUE 6” THERMOSTATS

BLUE 6” - UNIVERSAL AND SINGLE STAGE MODELS - 6 SQ. IN. DISPLAYBlue 6” Models Offer More Premium Features than Higher Priced Competitive Touchscreen Models.

F145-1328Indoor Remote Sensor

F145-1378Outdoor Remote Sensor

FEATURES•Universalmodelsquicklyconfigureforsinglestage,multi-stageorheatpumpand heat pump duel fuel systems - programmable or non-programmable •Easy Reader model is easy to read and easy to use. •Commercial offersoccupieddamperoreconomizercontrolandlockingcoverand subbase•Staging control for nearly all conventional and heat pump systems•Single stage model compatible with all single stage systems low voltage, 750 mV and 3-wire zone systems. 1F97-0671 not pictured.•HeatPumpdualfueloptioneliminatestheneedforafossilfuelkit.•Automaticchangeoveroption.•Programfanoptions.•Keypadlockoutandsetpointtemperaturelimitoptions.• Indoorremotesensorforaveragingoption.•OutdoorremotesensoroptiononselectUniversalmodelsforoutdoortemperature reading and dual fuel balance point or outdoor thermostat function (select models) •Dualpower-hardwireand/orbatteryorTripower-hardwireand/orbatterywith system assist.

PARTS AND ACCESSORIES See end of this section for additional parts and accessories

•F145-1328—IndoorRemoteSensor•F145-1378—OutdoorRemoteSensor•F61-2600—Wallplate81/8”W X 53/8”H•F61-2634—Wallplate61/2”W x 5”H(ororderF61-2648–6packofF61-2634)•F29-0198—LockingThermostatGuard-ClearPlastic•F29-0220—LockingThermostatGuard-Metal,SolidBase•AdditionalThermostatGuards—seepages24-25forquickselectionoptions

1F95EZ-0671

1F95-0671

SPECIFICATIONSElectrical Rating:Hardwire . . . . . . . . . . . . . . . . . . . . . . . . 20-30 VAC, NEC Class II 50/60HzBattery Power. . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DCTerminal Load. . . . . . . . . . . . . . . . . . . . 1.5 A per terminal, 2.5 A maximum all terminals combinedSetpoint Range. . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)Rated Differentials, Universal Models: Fast SlowHeat(Single Stage/Multi-Stage) . . . . . . 0.6°F 1.2°FCool (Single Stage/Multi-Stage) . . . . . . 1.2°F 1.7°FPump . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2°F 1.7°FEmer. Heat . . . . . . . . . . . . . . . . . . . . . . 1.2°F 1.7°FRated Differentials - Single Stage Models: Fast SlowHeat . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6°F 1.2°FCool . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2°F 1.7°FOperating Ambient . . . . . . . . . . . . . . . . 32 to +105°F (0 to +41°C)Operating Humidity. . . . . . . . . . . . . . . . 90% non-condensing max.Shipping Temperature Range. . . . . . . . -4 to +150°F (-20 to 65°C)Dimension. . . . . . . . . . . . . . . . . . . . . . . 43/16”H x 61/2”W x 15/8”D (17/8”D – Commercial model )

1F95-0680

THER

MO

STAT

S

www.white-rodgers.com10

Page 2: THERMOSTATS EMERSON BLUE 6 THERMOSTATSs3.supplyhouse.com/product_files/White Rodgers - 1F95-0680 - Brochure.pdfEMERSON BLUE 6” THERMOSTATS BLUE 6” - UNIVERSAL AND SINGLE STAGE

EMERSON BLUE 6”THERMOSTATS

UNIVERSAL STAGING/HEAT PUMP THERMOSTATS – EMERSON BLUE 6” THERMOSTATS

SingleStage

Multi-Stage

HeatPump Programs Model Applications

Ther

mos

tat P

ower

Sou

rce*

Selectable Performance FeaturesComfort and Convenience

Features Terminals

Stages Heat/Coolby System

Program Options

Periods Per Day Options

ModelNumber

Gas

/ O

il / E

lect

ric

3 W

ire Z

one

Valv

e

Mill

ivol

t Com

patib

le

Hum

idity

Con

trol

(H)-H

umid

ity /

(D)-D

ehum

idify

Aut

o C

hang

eove

r

Prog

ram

mab

le F

an

Ener

gy M

gt. R

ecov

ery

Dua

l Fue

l Hea

t Pum

p C

ontr

ol(L

)-Log

ic /

(O)-O

utdo

or S

enso

rK

eypa

d Lo

ckou

t(T

)-Tot

al /

(P)-P

artia

lSe

t-Poi

nt T

empe

ratu

re L

imits

Adj

usta

ble

Max

/Min

Indo

or R

emot

e Se

nsor

sM

ax. N

umbe

r + T

herm

osta

tAv

erag

e an

d/or

Wei

ghte

d

Out

door

Rem

ote

Sens

or

Dis

play

Siz

eSq

uare

inch

es

Ligh

ted

Dis

play

Coo

l Sav

ings

Mem

ory

Bac

k-U

p(P

)-Per

man

ent /

(B)-B

atte

ry

1/1 2/2 4/2 7, 5+1+1, Ø

4, 2, Ø 1F95-0680Universal

Commercial

3 3 3 B, H, PA

3 3 3 O‡ T, P 3 1 + 1 1t 6.0 3*** 3 P RC, RH, C, G, Y, Y2, W/E, W2, O/B, L, +,

S, -, 6, A11/1 2/2 4/2 7, 5+1+1,

Ø4, 2, Ø 1F95-0671

Universal3 3 3 B, H,

PA3 3 3 O‡ T, P 3 1 + 1 1t 6.0 3*** 3 P RC, RH, C, G, Y, Y2,

W/E, W2, O/B, L, 6, +, S, -

1/1 2/2 4/2 Ø, 7 2, 4 1F95EZ-0671Easy Reader

3 3 3 B, H, PA

3 3 3 L 3 6.0 3*** 3 P RC, RH, C, G, Y, Y2, W/E, W2, O/B, L

SINGLE STAGE THERMOSTAT – EMERSON BLUE 6” THERMOSTAT

SingleStage

Multi-Stage

HeatPump Programs Model Applications

Ther

mos

tat P

ower

Sou

rce*

Selectable Performance FeaturesComfort and Convenience

Features Terminals

Stages Heat/Coolby System

Program Options

Periods Per Day Options

ModelNumber

Gas

/ O

il / E

lect

ric

3 W

ire Z

one

Valv

e

Mill

ivol

t Com

patib

le

Hum

idity

Con

trol

(H)-H

umid

ity /

(D)-D

ehum

idify

Aut

o C

hang

eove

r

Prog

ram

mab

le F

an

Ener

gy M

gt. R

ecov

ery

Dua

l Fue

l Hea

t Pum

p C

ontr

ol(L

)-Log

ic /

(O)-O

utdo

or S

enso

rK

eypa

d Lo

ckou

t(T

)-Tot

al /

(P)-P

artia

lSe

t-Poi

nt T

empe

ratu

re L

imits

Adj

usta

ble

Max

/Min

Indo

or R

emot

e Se

nsor

sM

ax. N

umbe

r + T

herm

osta

tAv

erag

e an

d/or

Wei

ghte

d

Out

door

Rem

ote

Sens

or

Dis

play

Siz

eSq

uare

inch

es

Ligh

ted

Dis

play

Coo

l Sav

ings

Mem

ory

Bac

k-U

p(P

)-Per

man

ent /

(B)-B

atte

ry1/1 1/1 7, 5+1+1,

Ø4, 2, Ø 1F97-0671 3 3 3 B, H,

PA3 3 3 T, P 3 1 + 1 1t 6.0 3*** 3 P RC, RH, C, W, Y, G,

O, B, L, 6, +, S, -

* H=Hardwired(RequiresCommon) ‡ If F145-1378 outdoor remote sensor is not used, install manufacturers B,H=BatteryPoweredorHardwired fossilfuelkitforDualFuelapplications B = Battery Powered *** Optional Continuous Display Light w/ Hardwire connection PA = Power Saving Battery Assist t Only one (1) remote sensor may be used – either Indoor or Outdoor

?PAGES 134-143

TECHNICAL HELP1F97-0671 ..................... WiringDiagrams/Configuration ...............See pages 134-1351F95EZ-0671.................WiringDiagrams/Configuration ...............See pages 136-1371F95-0671 ..................... WiringDiagrams/Configuration ...............See pages 138-1401F95-0680 .....................WiringDiagrams/Configuration ...............See pages 141-143

THER

MO

STAT

S

www.white-rodgers.com 11