Bearing Wearing Monitor for TEIKOKU CANNED MOTOR PUMP
TRG (TEIKOKU ROTARY GURDIAN)
![Page 2: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/2.jpg)
(株)帝国電機製作所 2
Principle (Sensor Location)
A-A’ Sectional
![Page 3: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/3.jpg)
3
Principle Basic Wave A Groove Harmonics A
Compound Output ( A +
B)
Groove Harmonics B
![Page 4: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/4.jpg)
4
Principle
a
b
Bearing Worn Out a > b
TRG Indication gets Big
![Page 5: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/5.jpg)
5
Configuration & Option
• Sensor Coil• Anti-Rotating Detection
(Mold Circuit)• TRG Meter (Flame-Proof)• TRG Panel Meter (Option)• TRG Alarm (Option)• TRG Converter (Option)
![Page 6: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/6.jpg)
6
TRG Convertor
• TRG Signal is converted to 4-20(mA) or 1-5(V) which realizes centralized control.
• Flam Proof Explosion (d2G4) is available as option.
TRGコンバータ特性
4
6
8
10
12
14
16
18
20
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
TRG指示値
電流出力[mA]
1
1.5
2
2.5
3
3.5
4
4.5
5
電圧出力[V]
TRG Convertor Output
TRG Indication
(mA
)
(V)
![Page 7: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/7.jpg)
7
TRG Function
• Bearing Wearing Out
• 2-Phase Connection
• Wrong 3-Phase Connection Anti-Rotate
• Eccentric Assembly
• Unbalanced 3-Phase Amperage
• Unbalanced Induced Amperage on Rotor Defects
![Page 8: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/8.jpg)
8
TRG Indication at Start Up(With Anit-Rotating Detection)
Indication Root Cause Action
Full Scale Anti-Rotate Confirm Wire Assignment
Yellow~ Red 2(1) Phase Connection
Confirm Wire Connection
Green Good No
![Page 9: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/9.jpg)
9
TRG Indication during Running
Indication Condition Action
Green Safe No
Initial + 0.3Initial + 0.3
(Yellow)(Yellow)
CautionCaution Ready to Maintain
Initial + 0.5
(Red)
Danger Stop Pump
Initial TRG Value should be Recorded
![Page 10: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/10.jpg)
10
TRG Singnal
• With Anti-Rotating Detection (TRG Model : M, R) Diode Commutation, 350mVDC to Full Scale
• Without Anti-Rotating Detection (TRG Model : L, G) Raw TRG Signal AC1V to Full Scale Frequency < 3kHz
![Page 11: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/11.jpg)
11
Wiring to Outer Divices, TRG-Panel Meter, Alarm, and Convertor
• Wiring : Single Core Shielded Signal Wire 1.25mm2 or BiggerCore to G1 Terminal, Shield to G2 Terminal
• In case Double Core Wire is used, Core to G1 Terminal, Shield to G2 Terminal
• Shield must NOT be Grounded• Keep Away from Power Cable
![Page 12: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/12.jpg)
12
Wiring
TERMINAL BOX
TRG METER
TRG PANNEL METER
TRG ALARM
PANNEL
Shield must NOT be Grounded
![Page 13: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/13.jpg)
13
Other factors to vary TRG Indication
• Over LoadingSince TRG is sensing magnetic field generated by amperage on rotor, indication varies depending on loading.i.e. Flow Rate, SG, Viscosity,
• Ambient TemperatureDevises in TRG meter is affected by temperature but indication varies no more than 0.1 scale.
![Page 14: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/14.jpg)
(株)帝国電機製作所 14
誘導障害の確認
• 遠隔監視装置(パネルメータ、警報装置、TRGコンバータ)配線後 ,TRG指示値が黄色~赤色ゾーンであれば誘導障害の可能性があります。
• ポンプ端子台の G1,G2からシールド線の芯線及びシールドを外して運転し、端子箱のTRG指示値を確認して下さい。
• TRG指示値が黄~赤色→0.4以下になれば誘導障害を受けていることになります。
![Page 15: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/15.jpg)
(株)帝国電機製作所 15
誘導障害の対策
• 誘導障害を受けている場合、遠隔監視装置(パネルメータ、警報装置、TRGコンバータ)の入力 G1-G2間にダミー抵抗を入れてインピーダンスを下げてください。
• ダミー抵抗としては500 Ω~3 kΩ 1 /2W程度のものを用いてください。抵抗値は小さい方がよく効きます。
![Page 16: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/16.jpg)
(株)帝国電機製作所 16
インバータ駆動時のTRGについて• 回転方向検知付き(TRG型式:M ,R)の場合、インバータ駆動するとTRGは黄~赤色になり機能しなくなります。この場合、モールド回路を取り外す。メータや遠隔監視装置を交換するという作業が必要です。
↓• インバータ駆動する場合、回転方向検知無し(TRG型式:L ,G )を必ず選定してください。インバータのキャリア周波数は3 kHz以下で設定使用ください。
回転方向検知付きTRG選定不可!
キャリア周波数は必ず3 kH z以下に下げる
![Page 17: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/17.jpg)
(株)帝国電機製作所 17
インバータ駆動時のTRG管理についての注意事項
• TRGの管理の基本は、ある一定運転条件で初期値+ αの αがいくらになったかが管理の対象になります。(相対値管理)
• インバータ制御の場合、周波数一定にて管理をお願いします。 (例:50Hz 一定条件のTRG指示でチェックする)
![Page 18: Teikoku Rotary Guardian](https://reader035.vdocuments.mx/reader035/viewer/2022081413/546955f7af7959593e8b4716/html5/thumbnails/18.jpg)
(株)帝国電機製作所 18
回転方向検知付きTRGの注意事項• TRG回路と主電源回路が非絶縁です。
• TRG回路が絶縁不良になった場合、漏電検知器が作動する可能性あり。またこの場合、TRG指示値も高くなります。
図1.回転方向検知付TRGR S T
パネル取付形メータ テ イ コ ク
TRGメータ(AM-45)
G1 G2G1 G2 シ ー ル ト 線゙
回転方向検出回路(モールド回路) 端子箱
W
V TRG巻線
Uモータ巻線 ステータ