Technical Training 2007Technical Training 2007
TECHNICAL TRAINING TECHNICAL TRAINING
20072007
Technical Training 2007Technical Training 2007
SMART COMMANDERSMART COMMANDER
Technical Training 2007Technical Training 2007
System Requirements
• CPU : 800MHz and aboveCPU : 800MHz and above
• Memory : 256MB RAM or HigherMemory : 256MB RAM or Higher
• Hard Drive : 4G or higher for hard disk spaceHard Drive : 4G or higher for hard disk space
• OS : Windows 2000/XPOS : Windows 2000/XP
• Resolution : 1024 x 768 Resolution : 1024 x 768
• Monitor : Larger than 15 inch, & 17 inch is Monitor : Larger than 15 inch, & 17 inch is recommendedrecommended
• Serial port & USB port availableSerial port & USB port available
Technical Training 2007Technical Training 2007
User Login• Install the driver of encrypt USB keyInstall the driver of encrypt USB key
• Driver file: SP1730RC9.zipDriver file: SP1730RC9.zip
• Default user name: adminDefault user name: admin
• Password: mcquaymds (can be amend)Password: mcquaymds (can be amend)
Technical Training 2007Technical Training 2007
Menu Introduction
File MenuFile Menu
• ““Exit” onlyExit” only
Function MenuFunction Menu
• Initiating: Hardware changesInitiating: Hardware changes
• Error History: to record the faults in the system Error History: to record the faults in the system
• User Manager: to manage the user name & User Manager: to manage the user name & passwordpassword
• Parameter Setting: to set parameter of the Parameter Setting: to set parameter of the systemsystem
• Prompts for the units runningPrompts for the units running
Technical Training 2007Technical Training 2007
ID Monitor
From the 1From the 1stst tab on the left, user can perform tab on the left, user can perform related operation to the ID connected to ODrelated operation to the ID connected to OD
1. Select OD follow by ID 1. Select OD follow by ID
2. Select ID operation2. Select ID operation
3. Adjust ID temperature 3. Adjust ID temperature
4. Turn ON / OFF4. Turn ON / OFF
5. Click “Confirm” to achieve operation 5. Click “Confirm” to achieve operation
6. Double click to see Real Time Fault 6. Double click to see Real Time Fault
Technical Training 2007Technical Training 2007
Grouping & Timer
1. Click 1. Click
2. Select Default group number 2. Select Default group number
3. Select ID number3. Select ID number
4. Click to select the customized group 4. Click to select the customized group number (Max member in a customized is number (Max member in a customized is 4848))
5. Add the selected ID to the customized group5. Add the selected ID to the customized group
6. Edit the customized group name & ID name6. Edit the customized group name & ID name
7. Click “Edit” button to enter Timer setting7. Click “Edit” button to enter Timer setting
8. Timer Mode Setting8. Timer Mode Setting
Technical Training 2007Technical Training 2007
System Monitor
From the 2From the 2ndnd tab on the left, user can control the ID tab on the left, user can control the ID & OD & OD
1. Double click the ID icon. A window will pop up 1. Double click the ID icon. A window will pop up
2. Right click the ID icon, user can lock the ID2. Right click the ID icon, user can lock the ID
3. Indication of model icon 3. Indication of model icon
Technical Training 2007Technical Training 2007
Circuit & Server Monitor
Please connect Please connect ENCRPT USB KEYENCRPT USB KEY of PC, then of PC, then connect to Smart Commander software for connect to Smart Commander software for debugging.debugging.
Using service Using service ENCRPT USB KEYENCRPT USB KEY will not display will not display Circuit Monitor & Server Monitor. Please use Circuit Monitor & Server Monitor. Please use customer software after debugging. customer software after debugging.
Customer software will only display ID control & Customer software will only display ID control & system monitor interface.system monitor interface.
Technical Training 2007Technical Training 2007
Circuit Monitor
Used to monitor ALL parameter of ID & ODUsed to monitor ALL parameter of ID & OD
• Observe ALL parameter of OD through collect Observe ALL parameter of OD through collect address codeaddress code
Technical Training 2007Technical Training 2007
Circuit Monitor
• OD parameterOD parameter Single, Master, Slave
Cooling, Heating, Defrost, StopDisplay OD program
OD output capacity (Include Slave)OD output capacity (Include Slave)
TTsh_outsh_out: OD superheat: OD superheatDigital compressor output %Digital compressor output %
OD Fan: Stop, Low, HighOD Fan: Stop, Low, HighHS: High Pressure (bar)HS: High Pressure (bar) LS: Low Pressure (bar)LS: Low Pressure (bar)
Heating electronic expansion valve
Subcool electronic expansion valve
Bypass way valeHigh pressure / Low pressure switch
Technical Training 2007Technical Training 2007
Circuit Monitor
• OD parameterOD parameter
TH1: Discharge air temp
TH2: The 1st condenser entering temp
TH3: The 1st condenser middle temp
TH4: The 2nd condenser entering temp
TH5: The 2nd condenser middle temp
TH6: Entering water temp
TH7: Heating water temp
TH8: Outdoor temp
TH9: Temp before subcool
TH10: Temp after subcool
TH11: Subcool loop exit temp
TH12: Suction temp
Sensor is Sensor is unavailableunavailable
Technical Training 2007Technical Training 2007
OD System Theory Diagram
OD address numberOD address number RedRed Line: Heating Line: HeatingGreenGreen Line: Cooling / Dehumidify Line: Cooling / DehumidifyBlack LineBlack Line: Stop: Stop
Sensor position is hint positionSensor position is hint position
Technical Training 2007Technical Training 2007
ID System Diagram Parameters
Click “Up” or “Down”, Click “Up” or “Down”, ID address number will ID address number will move up or downmove up or down
Click “Back Page” Click “Back Page” or “Next or “Next Page”, the page will Page”, the page will turn up or downturn up or down
Address number of IDAddress number of ID
Technical Training 2007Technical Training 2007
ID System Diagram Parameters
Click “Ctrl” to set IDClick “Ctrl” to set ID• Choose optional parameters to control single unit Choose optional parameters to control single unit • Optional mode: Stop, Cooling, Heating, Dry, FanOptional mode: Stop, Cooling, Heating, Dry, Fan• Fan Speed: Low, Medium, High & AutoFan Speed: Low, Medium, High & Auto• Assistant function: Aux heater, Swing & LockAssistant function: Aux heater, Swing & Lock
Technical Training 2007Technical Training 2007
Circuit Monitor
1.1. Modify OD parameters settingModify OD parameters setting
• Defrost curve A, B point. Default setting A is Defrost curve A, B point. Default setting A is -6 -6 °C, B is -24 °C°C, B is -24 °C
• Defrost Finish Temp: defrost stop when TH9 Defrost Finish Temp: defrost stop when TH9 achieve this tempachieve this temp
• Defrost Interval Time: defrost stop when Defrost Interval Time: defrost stop when compressor runs for this interval time compressor runs for this interval time
• TscA1, TscA2, TscT1, TscT2, TscT3TscA1, TscA2, TscT1, TscT2, TscT3When TH9 ≤ TscA1, subcool is TscT1When TH9 ≤ TscA1, subcool is TscT1
When TscA1 < TH9 ≤ TscA2, subcool is TscT2When TscA1 < TH9 ≤ TscA2, subcool is TscT2
When TH9 > TscA2, subcool is TscT3When TH9 > TscA2, subcool is TscT3
Technical Training 2007Technical Training 2007
Server Monitor• Used to obtain graph for parametersUsed to obtain graph for parameters
• Observe operationObserve operation
• Input or Output data from parameters file Input or Output data from parameters file
• Max. 5 parameters will be displayedMax. 5 parameters will be displayed
• 5 colours on top left indicate the parameters5 colours on top left indicate the parameters
Technical Training 2007Technical Training 2007
Server Monitor
Coordinate code name
Idiographic machine address code• 1 digit – OD• 2 digit – ID
Detail parameter name
Y- axis scale
Technical Training 2007Technical Training 2007
Server MonitorFunction Button:Function Button:
Page of display section
No. of pages
Go back to 1st page
Go back to previous page
Go to next page
Go to the last page
Go to parameter setting
Output data
Technical Training 2007Technical Training 2007
Wiring Connection
Technical Training 2007Technical Training 2007
Thank YouThank You
Technical Training 2007Technical Training 2007
Error History Record
Technical Training 2007Technical Training 2007
User Manager
To add user:• Key in user name• Key in password
1. Click “Add”
To modify:• Key in user name• Key in new password
1. Click “modify”
To delete user:• Select the user in the list
1. Click “Delete”
Technical Training 2007Technical Training 2007
Parameters Setting
System shut down 3 minutes when switching from “cool” to “heat” or vice versa
Min. running time before switching to another mode
Lock screen interval time - Unit in seconds- Unlock password: mcquaymds
Click this will shown as follow
Technical Training 2007Technical Training 2007
Parameters Setting
Technical Training 2007Technical Training 2007
Stage History
Technical Training 2007Technical Training 2007
ID Monitor
Technical Training 2007Technical Training 2007
ID Monitor
1. Choose number of the OD
2. Choose number of the ID
Technical Training 2007Technical Training 2007
ID Monitor
Multiple Control :
Single Control: Select a indoor unit only
Select many indoor units
Group Control : All the indoor units in the system
Technical Training 2007Technical Training 2007
ID Monitor
Select fan speed:(must select)
Select mode (must select)
Select assistant functions:
Technical Training 2007Technical Training 2007
ID Monitor
Click “ ” or “ ”, can adjust the set temperature
Select “ ” or “ ”, can turn on or close the units
Click “ ”, can send the order to the units
Technical Training 2007Technical Training 2007
ID MonitorThe error list window pops upThe error list window pops up::
Technical Training 2007Technical Training 2007
Group Set & Timer
Technical Training 2007Technical Training 2007
Group Set & Timer
Select OD
Click on the cell to select ID
Technical Training 2007Technical Training 2007
Customized Group Setting
Technical Training 2007Technical Training 2007
Customized Group Setting
After select the ID, click this button To delete
the selected ID, click this button
Technical Training 2007Technical Training 2007
Customized Group Setting
To edit customized group name:
1. Key in group name
2. Click “Refresh”
To edit ID name:
1. Key in ID name
2. Click “Refresh”
Technical Training 2007Technical Training 2007
Timer Setting
To add/delete the timer mode:
1. Key in name
2. Click “Add” or “Delete”
Select Timer Mode
To Add, Delete or Modify a task
Technical Training 2007Technical Training 2007
Timer SettingFirst mode: Select ON/OFF task First mode: Select ON/OFF task
Technical Training 2007Technical Training 2007
Timer SettingSecond mode: Select only “Second mode: Select only “ONON” or only “” or only “OFFOFF” ”
Technical Training 2007Technical Training 2007
Timer Mode Setting
1. Select ID
3. Click “Set”2. Select Mode
Technical Training 2007Technical Training 2007
System Monitor
Technical Training 2007Technical Training 2007
System Monitor
Technical Training 2007Technical Training 2007
System Monitor
Left click to select the locked function
Technical Training 2007Technical Training 2007
System Monitor
Technical Training 2007Technical Training 2007
Circuit Monitor
Technical Training 2007Technical Training 2007
Circuit Monitor
Defined defrost area
Defrost stop
2nd defrost start after 1st defrost
TH9 ≤ TscA1, subcool is TscT1TH9 ≤ TscA1, subcool is TscT1TscA1 < TH9 ≤ TscA2, subcool is TscT2TscA1 < TH9 ≤ TscA2, subcool is TscT2TH9 > TscA2, subcool is TscT3TH9 > TscA2, subcool is TscT3
Technical Training 2007Technical Training 2007
Server Monitor
Value of the parameters
Move the pointer to the desired point
Technical Training 2007Technical Training 2007
Server Monitor
Y1~Y5: parameter setting:
Tick to select ID parameter to be displayed
Max. value of Y-axis
Min. value of Y-axis
Major unit
Display the data of selected date
Display the data of real time
Click to display the graph
Input file
Technical Training 2007Technical Training 2007
Server Monitor
Output Data: