SUMMARY TEST DATA ON
QC-2G18G-90
Unit 2
Page 1 of 7
7311-F Grove Road Frederick, MD 21704 USA Phone: (301)662-5019 Fax: (301)662-1731 Email: [email protected]
Customer: Tested By: Cody Wenner SO No: Temperature: +25°C
Model No: QC-2G18G-90 Date: 12/4/18 Serial No: Unit 2 Drawing No: Rev:
TEST ITEM
PARAMETERS SPECIFIED VALUE TEST
MEASUREMENT QA QC
1 Frequency Range 2.0 to 18.0 GHz 2.0 to 18.0 GHz
2 Nominal Split 3.01 dB 3.01 dB
3 Insertion Loss 1.2 dB Max 1.05 dB Max
See Plot
4 Isolation 20 dB Min
20.40 dB Min, 32.27 dB Max.
See Plot
5 Amplitude Balance ±0.5 dB Max
+0.445 dB / -0.380 dB
See Plot
6 Phase Balance ±5° +0° / -3.84° See Plot
7 VSWR 1.40:1 Max Input: 1.35:1
Output: 1.24:1 See Plot
8 Power Handling Average: 50 Watts Max
Peak: 1 KW Max Average: 50 Watts Max
Peak: 1 KW Max
9 Impedance 50 Ohms
50 Ohms
QA/QC Approval: ____________________________________ Date: __________________________
![Page 2: SUMMARY TEST DATA ON QC-2G18G-90 · Serial No: Unit 2 Drawing No: Rev: TEST ITEM PARAMETERS SPECIFIED VALUE TEST MEASUREMENT QA QC 1 Frequency Range 2.0 to 18.0 GHz 2.0 to 18.0 GHz](https://reader034.vdocuments.mx/reader034/viewer/2022052012/6029011502a5a02ed7576ab6/html5/thumbnails/2.jpg)
SUMMARY TEST DATA ON
QC-2G18G-90
Unit 2
Page 2 of 7
7311-F Grove Road Frederick, MD 21704 USA Phone: (301)662-5019 Fax: (301)662-1731 Email: [email protected]
INSERTION LOSS
![Page 3: SUMMARY TEST DATA ON QC-2G18G-90 · Serial No: Unit 2 Drawing No: Rev: TEST ITEM PARAMETERS SPECIFIED VALUE TEST MEASUREMENT QA QC 1 Frequency Range 2.0 to 18.0 GHz 2.0 to 18.0 GHz](https://reader034.vdocuments.mx/reader034/viewer/2022052012/6029011502a5a02ed7576ab6/html5/thumbnails/3.jpg)
SUMMARY TEST DATA ON
QC-2G18G-90
Unit 2
Page 3 of 7
7311-F Grove Road Frederick, MD 21704 USA Phone: (301)662-5019 Fax: (301)662-1731 Email: [email protected]
AMPLITUDE BALANCE
![Page 4: SUMMARY TEST DATA ON QC-2G18G-90 · Serial No: Unit 2 Drawing No: Rev: TEST ITEM PARAMETERS SPECIFIED VALUE TEST MEASUREMENT QA QC 1 Frequency Range 2.0 to 18.0 GHz 2.0 to 18.0 GHz](https://reader034.vdocuments.mx/reader034/viewer/2022052012/6029011502a5a02ed7576ab6/html5/thumbnails/4.jpg)
SUMMARY TEST DATA ON
QC-2G18G-90
Unit 2
Page 4 of 7
7311-F Grove Road Frederick, MD 21704 USA Phone: (301)662-5019 Fax: (301)662-1731 Email: [email protected]
INPUT VSWR
![Page 5: SUMMARY TEST DATA ON QC-2G18G-90 · Serial No: Unit 2 Drawing No: Rev: TEST ITEM PARAMETERS SPECIFIED VALUE TEST MEASUREMENT QA QC 1 Frequency Range 2.0 to 18.0 GHz 2.0 to 18.0 GHz](https://reader034.vdocuments.mx/reader034/viewer/2022052012/6029011502a5a02ed7576ab6/html5/thumbnails/5.jpg)
SUMMARY TEST DATA ON
QC-2G18G-90
Unit 2
Page 5 of 7
7311-F Grove Road Frederick, MD 21704 USA Phone: (301)662-5019 Fax: (301)662-1731 Email: [email protected]
OUTPUT VSWR
![Page 6: SUMMARY TEST DATA ON QC-2G18G-90 · Serial No: Unit 2 Drawing No: Rev: TEST ITEM PARAMETERS SPECIFIED VALUE TEST MEASUREMENT QA QC 1 Frequency Range 2.0 to 18.0 GHz 2.0 to 18.0 GHz](https://reader034.vdocuments.mx/reader034/viewer/2022052012/6029011502a5a02ed7576ab6/html5/thumbnails/6.jpg)
SUMMARY TEST DATA ON
QC-2G18G-90
Unit 2
Page 6 of 7
7311-F Grove Road Frederick, MD 21704 USA Phone: (301)662-5019 Fax: (301)662-1731 Email: [email protected]
ISOLATION
![Page 7: SUMMARY TEST DATA ON QC-2G18G-90 · Serial No: Unit 2 Drawing No: Rev: TEST ITEM PARAMETERS SPECIFIED VALUE TEST MEASUREMENT QA QC 1 Frequency Range 2.0 to 18.0 GHz 2.0 to 18.0 GHz](https://reader034.vdocuments.mx/reader034/viewer/2022052012/6029011502a5a02ed7576ab6/html5/thumbnails/7.jpg)
SUMMARY TEST DATA ON
QC-2G18G-90
Unit 2
Page 7 of 7
7311-F Grove Road Frederick, MD 21704 USA Phone: (301)662-5019 Fax: (301)662-1731 Email: [email protected]
PHASE BALANCE