Spyder® Introduction
2
Agenda
• Introductions• Review Spyder Hardware, Software & Accessories• Live Product Demonstration• Spyder Tool
- Physical Point Programming
- Network Point Programming
- Logic Programming
- Simulation
- Commissioning / Downloading / Alarms & Diagnostics
• Spyder Application Library- Library Migration
• Spyder Venom Tool
3
Best Practices
ZIO reviewMulti-controller & Plant ApplicationsVAV Balancing
4
Guy Zebrick
• Environmental Combustion and Controls division• Sales Representative / Contractor Support Specialist• 20+ Years Honeywell • Branch Commercial Construction Technician• Branch Project Manager• Branch Application / Lead Application engineer• Branch system sales• Contractor Support / Product specialist
5
Spyder Controller Features
Integrated Honeywell Actuator Reduce installation costs. AC synchronous actuator increases life of the controller and reduces life cycle costs
Integrated On-board Precision Pressure Sensor
Floating Actuator HousingActuator can float inside housing to increase life due to damper shaft run-out
Removable Terminal BlocksHard to reach places are easy to deal with.
Actuator De-Clutch
Color Coded Inputs and OutputsReduce wiring errors and speeds up troubleshooting.
Programmable Whatever you need Spydercan be programmed to solvethe problem.
DC Power SupplyPower external field devices without having to add additional power sources.Saves money and time.
Network Jack and Service PinEasy access network Jack and service pin for quick installation and easy service.
Sylk BusA two wire, polarity insensitive bus that provides both 18 Vdc power and communications between a Sylk-enabled sensor and a Sylk-enabled controller.
6
Fast Digital Pulse Meter
• One Universal Input (UI-1*) is user selectable as a fast digital Pulse Meter
• Pulse meter/Counter Input specification- Pulse input specifications:
- Max. frequency: 15Hz (54,000 pulses per hour)
- Min. pulse width: 20ms (debounced)
- Max. chatter: 5ms
7
Spyder VAV Controller with Actuator
ControllerModel
ProgrammableType Protocol UI DI AO DO
Velocity PressureSensor
(Microbridge)
Series 60FloatingActuator
PVB6436AS VAVBACnetMS/TP 6 4 3 6 YES YES
PVL0000AS VAV LonWorks 0 0 0 0 YES YES
PVL4022AS VAV LonWorks 4a 0 2 2 YES YES
PVL6436AS VAV LonWorks 6 4 3 6 YES YES
• 2 Digital Outputs reserved for Integrated Actuator
• Integrated Pressure Sensor
8
Spyder VAV Controller w/o Actuator
ControllerModel
ProgrammableType Protocol UI DI AO DO
Velocity PressureSensor
(Microbridge)
Series 60FloatingActuator
PVB6438NS VAVBACnetMS/TP 6 4 3 8 YES NO
PVL4024NS VAV LonWorks 4a 0 2 4 YES NO
PVL6438NS VAV LonWorks 6 4 3 8 YES NO
• Integrated Pressure Sensor
9
Spyder Unitary Controller
ControllerModel
ProgrammableType Protocol UI DI AO DO
Velocity PressureSensor
(Microbridge)
Series 60FloatingActuator
PUB6438S UnitaryBACnetMS/TP 6 4 3 8 NO NO
PUL1012S Unitary LonWorks 1a 0 1 2 NO NO
PUL4024S Unitary LonWorks 4a 0 2 4 NO NO
PUL6438S Unitary LonWorks 6 4 3 8 NO NO
• Extended Temperature Rating
Pro
gram
mab
le Un
itary Co
ntro
l
Programmable Unitary Controller• Extended Temperature Rated -40° F
(-40° C) to 150° F (65.5° C)
Programmable Variable Air Volume Controller• Integrated actuator• Integrated on-board pressure sensor
Programmable Variable Air Volume Controller• Integrated on-board pressure sensor
PUL1012S – LonWorks Inputs• 1 universal input• 0 digital inputsOutputs• 1 analog output• 2 digital outputs
PUL4024S – LonWorks Inputs• 4 universal inputs• 0 digital inputsOutputs• 2 analog outputs• 4 digital outputs
PUL6438S – LonWorksInputs• 6 universal inputs• 4 digital inputsOutputs• 3 analog outputs• 8 digital outputs
PUB6438S – BACnet Inputs• 6 universal inputs• 4 digital inputsOutputs• 3 analog outputs• 8 digital outputs
PVL0000AS – LonWorks Inputs• 0 universal inputs• 0 digital inputsOutputs• 0 analog outputs• 0 digital outputs
PVL4022AS – LonWorks Inputs• 4 universal inputs• 0 digital inputsOutputs• 2 analog outputs• 2 digital outputs
PVL6436AS – LonWorksInputs• 6 universal inputs• 4 digital inputsOutputs• 3 analog outputs• 6 digital outputs
PVB6436AS – BACnet Inputs• 6 universal inputs• 4 digital inputsOutputs• 3 analog outputs• 6 digital outputs
PVL4024NS – LonWorksInputs• 4 universal inputs• 0 digital inputsOutputs• 2 analog outputs• 4 digital outputs
PVL6438NS – LonWorksInputs• 6 universal inputs• 4 digital inputsOutputs• 3 analog outputs• 8 digital outputs
PVB6438NS – BACnet Inputs• 6 universal inputs• 4 digital inputsOutputs• 3 analog outputs• 8 digital outputs
BACnet MS/TP
LON
Programmable Unitary Controllers
Programmable VAV Controllers with Actuator
Programmable VAV Controllers w/o Actuator
11
New Licensing Scheme
• The Spyder Tool checks the license for features- As of Spyder Tool 4.X and later
• There are two Spyder features- SpyderProgrammable for the Lon Spyders
- SpyderBACnetProgrammable for the BACnet Spyders
• Spyder features are only available on WEBS branded JACE’s and Supervisor Engineering Demo’s- W-ENG-AX-DEMO
12
Spyder-ILC
• The Spyder-ILC is an individually licensed controller- Spyder-ILC controllers will accept a download from the
Spyder Tool regardless of the brand of workstation/JACE
- In other words, features within the license are ignored
• The Spyder-ILC’s have the same OS number with an “-ILC” suffix- Example: PUL6438S-ILC, PVB6436AS-ILC, PVL4022AS-ILC
• 20% adder per Spyder-ILC for licensing fee- No one else in the industry offers a programmable controller
that can be programmed on ANY AX front end!
• Like all Spyders, the ILC can only be sold to Honeywell ACS or ACI contractors
13
Scenario – WEBS Brand JACE
WEBS Brand Workbench WEBS Brand JACESpyder Feature
Honeywell Spyder
3rd Party Brand Workbench WEBS Brand JACESpyder Feature
Honeywell Spyder
14
Scenario – WEBS OPEN Brand JACE
WEBS “OPEN” Brand JACESpyder Feature
Honeywell Spyder
Honeywell Spyder-ILCWEBS “OPEN” Brand JACESpyder Feature
ANY Brand Workbench
ANY Brand Workbench
Not Typical
15
Scenario – 3rd Party JACE
ANY Brand Workbench 3rd Party Brand JACE Honeywell Spyder
ANY Brand Workbench 3rd Party Brand JACE Honeywell Spyder-ILC
16
Scenario – No JACE
Honeywell Spyder
ANY Brand Workbench
3rd Party Brand Workbench
Honeywell SpyderWEBS Brand EngineeringDemo Supervisor
Honeywell Spyder-ILC
17
Scenario – Existing Support
• Existing WEBS job needs to be expanded- 1. Keep existing workbench and tool; add Spyders as
needed License change doesn’t affect a job already installed
- 2. Get new license with correct Spyder Features If using 403 or 545, the appropriate feature is needed
• Existing job with 3rd party JACE and Spyders, needs to be expanded- 1. Keep existing workbench and tool; add Spyders as
needed License change doesn’t affect a job already installed
- 2. Upgrade to latest Spyder Tool and use ILC to expand Previous Spyders must be brought in as 3rd party devices and you
won’t be able to download to them
18
Freely Programmable
• Just determine your requirements, then program Spyder to control it all
19
Spyder Palette
21
Application Library
23
Program Simulator and Debug Mode
25
Macros
27
Adaptive Integral Algorithm
• Honeywell’s Adaptive Integral Algorithm (AIA) Control is the most accurate control available for space control applications
28
Model Numbers
P V L 6 4 3 6 A S
P – Programmable
U – UnitaryV – VAV
L – LONB – BACnet
Number of Universal Inputs
Number of availableDigital Outputs
A – With ActuatorN – Without Actuator
Number of Digital Inputs
Number of Analog Outputs
S – Sylk Bus
29
Spyder Lon Specific Details
• Free Topology Transceiver (FTT)- High-speed 78 kilobit communications network
• Function Blocks- 200 Function Blocks max per controller
• Lon Network Variables- 240 total NV’s per controller
20 Mandatory NVs 7 Fixed NVs 213 User Defined NVs
• Support for up to 120 controllers per LonWorks channel
30
Spyder BACnet Specific Details
• BACnet MS/TP LAN communication network - Capable of baud rates between 9.6 and 115.2 kilobits
• BTL B-ASC- BACnet Testing Laboratories B-ASC (BACnet Application
Specific Controller)
- Certification Testing in process
• BACnet PICS (Protocol Implementation Conformance Statement)- Refer to the PICS for information on:
BIBBs – BACnet Interoperability Building Blocks BACnet Device Objects
• Support for up to 30 controllers per BACnet MS/TP LAN Segment
31
Spyder FAQ’s
• Should I use a Spyder if the current XL10 meets the sequence or requirements?
• Do you want to order the Spyder with Actuator when you need to separate the actuator and controller?
- What Actuators are recommended for use with the Spyder VAV controllers without Actuators?
Depends on application
NO
ML6161, ML6174, MN6105
32
WEB-600 SEC-H-600
SecurityElevator Control
Access ControlTime and Attendance
Intrusion Keypad/Display
Lighting
Control
WEB BrowserWEB Browser
WEB Station
34 pt I/OVideo Monitoring
and Control
RS-485RS-485
UV
WEB-600
CVAHU
Spyder Lon
Spyder Lon
Spyder Lon
Spyder BACnet
Spyder BACnet
Spyder BACnet
HTTP, XML, BACnet, SNMP, oBIX
T7350
Architecture
Internet
34
Sylk™ Bus
• Sylk is a two wire, polarity insensitive bus that provides both 18 Vdc power and communications between a Sylk-enabled sensor and a Sylk-enabled controller
• Devices- Zio LCD Wall Module
TR70 TR70-H
• Future- TR20 Series
- Sylk IO Addressing the combined needs of the
Building Automation and Field Device team
35
TR20 Series Wireless Overview
• Point to Point- Direct replacement for a wired sensor
- Can be used with Spyder, XL10, T7350 thermostats, SuitePRO
- Not compatible with Commercial VisionPRO & CommercialPRO thermostats
• Two Sensor options- With temperature only
TR21-WK kit or TR21-WS sensor only
- With temperature, setpoint knob, and override button TR23-WK kit or TR23-WS sensor only
• On board signal strength indicator- No need for diagnostic tool
• Beta in progress – Thank You!
Receiver
Wireless sensor
Replace a wired sensor, without the wires!
36
Noteworthy Installations
• Prairie View School District, Saskatchewan
37
Noteworthy Installations
• Target Field (Twins Stadium) - Minneapolis
38
Noteworthy Installations
• ACS Headquarters – Golden Valley
39
Noteworthy Installations
• Adelphia Labs, New Jersey
40
Noteworthy Installations
• Vectura Pharmaceutical, United Kingdom
41
Noteworthy Installations
• Claridges Hotel, Delhi
42
Spyder Tool Demonstration
www.honeywell.com