Software rel. 2.3.x
RPM INDICATOR VERSION
2
CONTENTS
● Legendofsymbols.....................................................................................................3INTRODUCTION ............................................................................................................4 Productdescription....................................................................................................4INTENDED USE .............................................................................................................4CONTENT OF THE PACKAGE .....................................................................................4PRECAUTIONS .............................................................................................................4RISKS AND PROTECTIONS BEFORE ASSEMBLY ....................................................5 Positioning..................................................................................................................5 Powersupplyandsensorconnection........................................................................5ASSEMBLY DIAGRAMS ...............................................................................................6CONTROLS IN THE MENU ...........................................................................................7 Firstswitchingon.......................................................................................................7 Controlsinthemenu..................................................................................................8MENU STRUCTURE ....................................................................................................10 RPMAlarms............................................................................................................. 11 Sensors....................................................................................................................12 Sensors>Manualcalibration...................................................................................13 Language.................................................................................................................14 Displaycontrast........................................................................................................14 Alarmtones..............................................................................................................15 Keytones..................................................................................................................15 Displaysettings........................................................................................................16 Operatingmode.......................................................................................................17 Setupmanagement..................................................................................................18 Testmenu.................................................................................................................20USE ..............................................................................................................................22 Partialtotalizerreset................................................................................................22MAINTENANCE / DIAGNOSTICS / REPAIRS ............................................................23 Troubleshooting........................................................................................................23END OF LIFE DISPOSAL ............................................................................................23TECHNICAL DATA ......................................................................................................24 Devicetechnicaldata...............................................................................................24 Setupmenu..............................................................................................................25GUARANTEE TERMS .................................................................................................26
3
● Legendofsymbols
= Genericdanger
= Warning
This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.
4
INTRODUCTION
Productdescription
VISIOisaverycompactandaccuratetop-notchmultifunctiondisplay,abletodisplayanykindofinformationconcerningagriculturaltreatments.Operatorcanselecttherequiredfunctionviasoftware.Itcandisplayseveraltypesofvalues,whichchangeaccordingtosetoperatingmodeandtypeofconnectedsensors.
INTENDED USE
This device is designed towork onagriculturalmachinery for spraying and cropsprayingapplications.ThemachineisdesignedandbuiltincompliancewithENISO14982standard(Electromagneticcompatibility-Forestryandfarmingmachines),harmonizedwith2014/30/UEDirective.
CONTENT OF THE PACKAGE
ThetablebelowindicatesthecomponentsthatyouwillfindintheVISIOpackage:
Legend:
1 VISIO2 Fixingkit3 Instructionmanual (onCD-ROM)4 Installationsheet
PRECAUTIONS
•Donotaimwaterjetsattheequipment.•Donotusesolventsorfueltocleanthecaseoutersurface.•Donotcleanequipmentwithdirectwaterjets.•Complywiththespecifiedpowervoltage(12VDC).•Incaseofvoltaicarcwelding,removeconnectorsfromVISIOanddisconnectthepowercables.•OnlyuseARAGgenuinesparepartsandaccessories.
P o w e r c a b l e ,s e n s o r s a n dconnection cablesto be connectedto VISIO must beorderedseparately.
5
RISKS AND PROTECTIONS BEFORE ASSEMBLY
Allinstallationworksmustbedonewithbatterydisconnected,usingsuitabletoolsandanyindividualprotectionequipmentdeemednecessary.
Positioning
1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs.2) Secure VISIO to rail and push down until locked in place.3) Fasten wiring so that it does not interfere with any moving parts.
Powersupplyandsensorconnection
Sensorsandpowersupplymustbeinstalledandconnectedbyqualifiedpersonnel.VISIOmustbeexclusivelyconnectedtoARAGequipment.WHENARCWELDINGISREQUIRED,MAKESURETHATEQUIPMENTPOWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF NEEDED.ARAGisnotliablefordamagetothesystem,persons,animalsorpropertycausedbyVISIOwrongorunsuitableassembly.Failuretoobservetheaboveinstructionsautomaticallyvoidsthewarranty.
Wirecolor (powercable) Connectionof
red positive
black negative
green countingabort-groundconnection
yellow countingabort-connection+12VDC
power supplysensors
6
ASSEMBLY DIAGRAMS
Counting abortGround connection
(green wire)
5
3
4
+12Vdc
GND
Counting abortConnection
+12VDC
(yellow wire)
Legend:
1)Powercable2)Connectioncableforsinglesensor3)Connectioncablefordoublesensor*4)Rpmsensor15)Rpmsensor2**=optional, according to the selected configuration.
7
CONTROLS IN THE MENU
Firstswitchingon
Atfirstswitchingon,VISIOwillrunaguidedprocedureallowingusertosetthedevice'sbasicsettings.
Press toscrollthroughitems,OKtosaveandmoveontonextsetting,orESCtogobacktoprevioussetting.
WARNING:Beforechangingoperatingmode,makesurethatallsensors/flowmetersareDISCONNECTEDfromthedevice.
8
Controlsinthemenu
Inthefollowingpages,accordingtothesetoperatingmode,somemenuitemscouldslightlydifferfromtheshownones.
SWITCHING ONAPressfor1secondBPressthekeyafewtimestoviewthevariousvaluesinextendedmode,(ondisplaycentralpart)Everytimethedeviceisswitchedon,itwillshortlyshowapagewiththenameofdeviceandsoftwareversion.
SWITCHING OFFAPressfor2seconds
ACCESS TO SETUP MENUFromthemainpage,presskeysatthesametimefor2secondstoopentheSetupMenu.
9
SELECTION AND ACCESS TO MENU ITEMS
APressafewtimestoscrollthroughitems(selecteditemisindicatedbyablackline)BPresstoopentheselectedmenuitem
Thethreedotsunderanitemindicatepresenceofanothersetupmenu.
EDITING A VALUE
APresstomovethroughdigitsBPressafewtimestoeditthehighlighteddigitCPresstoconfirm.ThedisplaygoesbacktopreviouspageDPresstoexitpagewithoutconfirmingmodification
Editedvaluemustfallwithintherangeshown.
10
MENU STRUCTURE
0 rpm1
01
1
MIN
0 rpmMAX
rpm
Alarms
Sens. 1-2 min RpmSens. 1-2 max Rpm
Sensors
Rpm 1Rpm 2
Man. calibration
Options
Language
Data 1Data 2Data 3
Display contrast
Alarm tones
Keytones
Display settings
Rpm sensor 1-2Sens. 1-2 min RpmSens. 1-2 max RpmRpm sens. 1-2 time
}Operating mode
Setup management
Save setupLoad setup
Test
Firmware versionBattery voltageDisplayKeysSensors
Rpm
11
RPMAlarms
SetthedesiredalarmdisplaythresholdsforminimumandmaximumRpmvalues.
1)OpenAlarmmenu(Setupmenu>Alarms).
MinimumandmaximumRpmalarmsaresetinthesameway.
Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
Thismenuallowssettingtwodifferentsensors(ifavailable).
Incaseonlyonesensorisused,useitemsrelatedtosensor1toperformthecorrectsettings.
2)Toactivatethealarm,press and
atthesametimeuntilmessage OFFgoesoffandtheRpmalarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
12
Sensors
1)OpenSensorsmenu(Setupmenu>Sensors).
Themenuitemsdisplayedbelowchangeaccordingtothesetoperationmode:whenmoreitemsareavailable,selectthedesiredoneandpressOKtoeditit.
13
Sensors>Manualcalibration
VISIOprocesses the rotationspeed information related toaspecificpart throughthepulsesfromtheRpmsensor.ThemanualcalibrationallowsenteringtheRpmconstantvalue.
1)OpenSensorsmenu(Setupmenu>Sensors).
2)Presstoopenmanualcalibrationmode.
Thismenuallowssettingtwodifferentsensors(ifavailable).Incaseonlyonesensorisused,useitemsrelatedtoRpm1toperformthesettings.
3)SettheRpmconstantvalue,i.e.thenumberofdetectionpoints,suchasmagnetsorboltsfittedontherotatingshaftwhoserotationspeedshallbedetected:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C) Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.
14
Language
Setthedesiredlanguage.
Alarm tones
Display contrast
Openlanguagesettingmenu(Setupmenu>Options>Language).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectthelanguage.
2 1
2
Language
English
ČeskDeutsch
Español
1)Selectalanguagethrough .
2)PressOKtosave,orESCtoquitwithoutsaving.
Displaycontrast
Setdisplaycontrast.
Options
Language
Alarm tones
Display contrast50%
Opendisplaycontrastmenu(Setupmenu>Options>Displaycontrast).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
1)Setavaluethrough .Everytime
youpressit,valuewillincreaseby5%up
to100%.Use keytodecreasevalue
by5%.2)PressOKtosave,orESCtoquitwithoutsaving.
15
Alarmtones
Enable/disablethealarmtones.
OpenAlarmtonesmenu(Setupmenu>Options>Alarmtones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
1)Setstatusthrough key.
2)PressOKtosave,orESCtoquitwithoutsaving.
Keytones
Enable/disablekeytones.
1)Openkeytonesmenu(Setupmenu>Options>Keytones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.
1)Setstatusthrough .
2)PressOKtosave,orESCtoquitwithoutsaving.
16
Displaysettings
Themain page shows the display dividedinto three horizontal parts, which can beseparatelyreset(accordingtothevalue).Everysectorcanbeassignedthedesiredvalue:
-Rpmsensor1-2=Rpmlivereading;-Min.Rpmsens.1-2=minimumdetectedRpm;-Max.Rpmsens.1-2=maximumdetectedRpm;-Rpmsens.1-2time=value,measuredinseconds,duringwhichVISIOhasdetectedamovementdifferentfrom0.
OpenDisplaysettingsmenu(Setupmenu>Options>Displaysettings).Press OK toedittheselectedmenuitem.
1)Selectvaluethrough .
2)PressOKtoedit,orESCtoquitwithoutsaving.
1)Setsectortotherequiredvalue
through .
2)PressOKtosave,orESCtoquitwithoutsaving.Carryoutthesameprocedurefortheother2values.
17
Operatingmode
Setrequiredoperatingmode.
Openoperatingmodemenu(Setupmenu>Options>Operatingmode).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK tochangetheoperatingmode.
1)Selecttherequiredoperatingmode
through .
2)PressOK tosave,orESC toquitwithoutsaving.
WARNING:OnceOKispressed,thepageontwhesidewillbedisplayed.Beforechangingoperatingmode,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmchanges.ConnectthesensorsREQUIREDFORTHE SET OPERATING MODE.
18
Setupmanagement
VISIOsettingscanbeloadedfromorsavedonaUSBpendriveinordertoreconfigureit ifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallmanualoperations.Onceinstallationiscompleted,andVISIOoperationhasbeenchecked,werecommendtosaveallsettingsontoaUSBpendrive.TobeabletousethefollowingfunctionsitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.
1)OpenSetupmanagementmenu(Setupmenu>Setupmanagement).
PressOK toedittheselectedmenuitem.
Load setupAllowstoselectaconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.WARNING:ByloadingtheSETUP.BIN filecontainedintheUSBpendriveontotheVISIO,allcurrentsettingswillbelost.
1)Selectthedesiredcontrolthrough key.2)PressOK toconfirmloading,orESC toquitwithoutsaving.
TheSETUP.BINfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.Ifsetupdownloadinvolveschangingoperatingmodeandusingdifferentsensorsthantheonesinuse,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmloading.Reconnectsensors.
19
Save setupAllowssavingVISIOconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.
1)Selectthedesiredcontrolthrough
key.2)PressOK toconfirmsaving,orESC toquitwithoutsaving.
IfaSETUP.BINfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.
20
Testmenu
ThismenuallowsusertoviewsomedataandcarryoutanoperationtestofVISIO:-Firmwareversion:thedisplayshowsthefirmwareversioninstalled.-Batteryvoltage:thedisplayshowsthepowervoltageofthedevice.
Display test
Displaytestchecksthedevicedisplaycorrectoperation.
1)Opendisplaytestmenu(Setupmenu>Test>Display).Press OK toperformthetest.
Allpixelsondisplayareturnedon.PressESCtogobacktopreviouspage.
Keys test
Keystestchecksthedevicekeyscorrectoperation.
Openkeystestmenu(Setupmenu>Test>Keys).
Press OK toperformthetest.
1)Pressanykeyandthecorrespondingdisplayareawillturnon.PressESC toquit:assoonasyouacknowledgetheswitch-ononofthecorrespondingareaonthedisplay,devicewillgobacktopreviouspage.
21
Sensors test
Sensorstestcheckscorrectoperationofthesensorsconnectedtothedevice.
Opensensorstestmenu(Setupmenu>Test>Sensors).
Press OK toperformthetest.
Thedisplaywillshowthecurrentsensorreadingbelowtheselecteditem.1)Severalsensorscouldbedisplayed,dependingonthesetoperatingmode.Inthiscase,selectrequiredsensor
through .
2)PressESCtoquit.
22
USE
Activatetherotatingpart.Thedisplaywillstartshowingthedetectedvalue.
Partialtotalizerreset
Toresetatotalizeryoumustviewitinextendedmode.Presskeyseveraltimesuntilvaluetoberesetisatthecentralareaofthedisplay.
Press keyfortwoseconds.
Totalizerresets.
Symbol-----indicatesthatthevalueexceedsthemaximumvaluethatcanbedisplayed.Totalizersdisplaymaximum4digits.
23
MAINTENANCE / DIAGNOSTICS / REPAIRS
•Cleanonlywithasoftwetcloth.•Donotuseaggressivedetergentsorproducts.•Donotcleanequipmentwithdirectwaterjets.
Troubleshooting
FAULT CAUSE REMEDY
VISIOisoffordoesnotswitchon
Nopowersupply Checkpowercableconnections
DeviceisOFF PresstheONkey
VISIOshowswrongdata
Wrongsetup Checkdisplayeddatasetup
Sensorfault ContactthenearestAssistanceCenterVISIOfault
Fillingpump(ifany)doesnotstart
PumpStopModulenotpowered
Checkpowersupplyconnection
END OF LIFE DISPOSAL
Disposeofthesystemincompliancewiththeestablishedlegislationinthecountryofuse.
24
TECHNICAL DATA
Devicetechnicaldata
Description VISIO
Display GraphicLCD,128x64pixels,back-lighting
Powersupplyvoltage 9÷16Vdc
Protectionagainstshort-circuit •
Protectionagainstpolarityinversion •
Max.frequency 1.2KHz
Analoginputs 4÷20mA
Digitaloutput-Maxcurrent 100mA
Maximumpowerinput(withnosensorsconnected) 160mA
Operatingtemperature -20°C÷70°C-4°F÷+158°F
Storagetemperature -30°C÷80°C-22°F÷+176°F
Size 126x79x66mm
Weight 245g
25
Setupmenu
Data Min. Max. Default UoM Notes
Sensor Calibration 1.0 200.0 60.0 pls/l --
Rpm alarms
Min.RPM 1 9999 OFF RPM Alarmcanbedisabledbysettingvalueto"OFF"
Max.RPM 1 9999 OFF RPM Alarmcanbedisabledbysettingvalueto"OFF"
Display Contrast 0 100 50 % --
Options Language - - English -
Availablelanguages:Italiano,English,Español,Português,Français,Deutsch,Cesky,Polski,Русский,Magyar,ニホン .
26
GUARANTEE TERMS
1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateofsaletotheclientuser(dateofthegoodsdeliverynote).Thecomponentsoftheapparatus,thatintheunappealableopinionofARAGarefaultyduetoanoriginaldefectinthematerialorproductionprocess,willberepairedorreplacedfreeofchargeatthenearestAssistanceCenteroperatingatthemomenttherequestforinterventionismade.Thefollowingcostsareexcluded:
- disassemblyandreassemblyoftheapparatusfromtheoriginalsystem;- transportoftheapparatustotheAssistanceCenter.2. Thefollowingarenotcoveredbytheguarantee:- damagecausedbytransport(scratches,dentsandsimilar);- damageduetoincorrectinstallationortofaultsoriginatingfrominsufficientor
inadequatecharacteristicsoftheelectricalsystem,ortoalterationsresultingfromenvironmental,climaticorotherconditions;
- damageduetotheuseofunsuitablechemicalproducts,forspraying,watering,weedkillingoranyothercroptreatment,thatmaydamagetheapparatus;
- malfunctioningcausedbynegligence,mishandling,lackofknowhow,repairsormodificationscarriedoutbyunauthorizedpersonnel;
- incorrectinstallationandregulation;- damageormalfunctioncausedbythelackofordinarymaintenance,suchascleaning
offilters,nozzles,etc.;- anythingthatcanbeconsideredtobenormalwearandtear.3. Repairingtheapparatuswillbecarriedoutwithintimelimitscompatiblewiththe
organizationalneedsoftheAssistanceCenter.Noguaranteeconditionswillberecognizedforthoseunitsorcomponentsthathavenotbeenpreviouslywashedandcleanedtoremoveresidueoftheproductsused;
4. Repairscarriedoutunderguaranteeareguaranteedforoneyear(360days)fromthereplacementorrepairdate.
5. ARAGwillnotrecognizeanyfurtherexpressedorintendedguarantees,apartfromthoselistedhere.NorepresentativeorretailerisauthorizedtotakeonanyotherresponsibilityrelativetoARAGproducts.Theperiodoftheguaranteesrecognizedbylaw,includingthecommercialguaranteesandallowancesforspecialpurposesarelimited,inlengthoftime,tothevaliditiesgivenhere.InnocasewillARAGrecognizelossofprofits,eitherdirect,indirect,specialorsubsequenttoanydamage.
6. ThepartsreplacedunderguaranteeremainthepropertyofARAG.7. Allsafetyinformationpresentinthesalesdocumentsregardinglimitsinuse,
performanceandproductcharacteristicsmustbetransferredtotheenduserasaresponsibilityofthepurchaser.
8. AnycontroversymustbepresentedtotheReggioEmiliaLawCourt.
CONFORMITY DECLARATION
1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateof
42048 RUBIERA (Reggio Emilia) - ITALYVia Palladio, 5/ATel. +39 0522 622011Fax +39 0522 [email protected]
Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com
D20
287_
GB
-m04
03/2
017